USB-9237 [NI]

Strain- and Bridge-Based Measurements; 应变和桥基测量
USB-9237
型号: USB-9237
厂家: National Instruments    National Instruments
描述:

Strain- and Bridge-Based Measurements
应变和桥基测量

文件: 总4页 (文件大小:963K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Strain- and Bridge-Based Measurements  
NI USB-9237  
• Full-, half-, and quarter-bridge  
Compatible Software  
• LabVIEW  
• LabWindows/CVI  
• Measurement Studio  
• Visual Basic 6.0  
(120/350 Ω) completion1  
• Bus powered  
• Built-in excitation up to 10 V  
• Up to 50 kS/s/ch sample rate  
• Simultaneous acquisition with  
four ADCs  
• Quick sensor connect with  
RJ50 connectors  
• C# and Visual Basic .NET  
• ANSI C/C++  
Measurement Services  
Software (included)  
• NI-DAQmx driver software  
• Measurement & Automation Explorer  
configuration utility  
• TEDS (IEEE 1454.1) compatible  
• External excitation input through analog  
bridge (optional)  
1Quarter bridge requires accessory.  
• LabVIEW SignalExpress LE  
data-logging software  
Operating Systems  
• Windows Vista/XP/2000  
Overview  
Connectivity  
The National Instruments USB-9237 combines performance and  
portability by making the NI 9237 C Series module compatible with the  
bus-powered USB carrier for C Series modules. This module is ideal for  
laptop applications because the USB port on the laptop powers all  
acquisition and sensor excitation.  
The USB-9237 uses four standard RJ50 connectors for rapid sensor  
connection. You can add an RJ50 connector to any sensor using a  
crimping tool, making sensor removal and insertion as easy as  
connecting a PC to a network. For screw-terminal connectivity, the  
NI 9949 accessory kit converts from RJ50 to 10 screw terminals. RJ50  
cable kits are available in quantities of four 2 m cables and one 10 m  
cable. For custom sensor wiring, cable kits are available with an RJ50  
connector on one end and 10 signal wires on the other.  
High-Speed Measurements  
The NI USB-9237 module can take measurements at up to 50 kS/s on  
four channels simultaneously and continuously stream the data back  
over a Hi-Speed USB interface to serve applications from static load  
or fatigue testing to high-speed fracture tests.  
Software  
The USB-9237 is shipped with the standard NI-DAQmx bundle that  
includes Measurement & Automation Explorer (MAX) for configuration  
and testing; LabVIEW SignalExpress LE for out-of-the-box measurements,  
logging, and data display; and an API/driver for languages such as  
LabVIEW, ANSI C, C#, Visual Basic .NET, Visual Basic 6.0, Measurement  
Studio, and LabWindows/CVI.  
Sensor Compatibility  
With full-, half-, and quarter-bridge completion, the USB-9237 can  
measure a variety of load, force, and torque cells as well as some  
pressure transducers and most strain gages.1  
Safety Isolation  
• 30 V of overvoltage protection  
• 60 V of CAT I channel-to-earth ground isolation  
• 1000 V of transient withstand isolation  
1Quarter bridge requires accessory.  
Strain- and Bridge-Based Measurements  
Excitation Voltages  
Specifications  
Although the sensor industry does not recognize a single standard  
excitation voltage level, excitation voltage levels of between 2.5 and  
10 V are common. You can program the USB-9237 to supply 2.5, 3.3,  
5, or 10 V of excitation voltage, and the module can provide up to  
150 mW of excitation power. Unless you supply external excitation  
voltage, National Instruments recommends that you set the excitation  
voltage to a value that keeps the total power below 150 mW. The  
USB-9237 automatically reduces internal excitation voltages as needed  
to stay below 150 mW.  
>> For complete specifications, see the NI USB-9237 User Guide and  
Specifications manual at ni.com/manuals.  
Input Characteristics  
Number of channels............................  
Bridge completion  
Full and half.................................... Internal  
Quarter............................................ External  
ADC resolution................................ 24 bits  
Type of ADC.................................... Delta-sigma  
4
The power consumed by a single bridge is  
(with analog prefiltering)  
Sampling mode............................... Simultaneous  
2
Vex  
Data rates (ƒ ) ................................. (50 kS/s)/n, n= 1, 1, …31  
---------  
R
s
Master timebase (internal)  
Frequency........................................ 12.8 MHz  
Accuracy ......................................... 100 ppm max  
Nominal full-scale range................ 25 mV/V  
Scaling coefficient .............................. 2.9802 nV/V per LSB  
Overvoltage protection  
where R is the total resistance of the bridge.  
For a full bridge, R is equal to the resistance of each element. For a  
half or quarter bridge, R is equal to two times the resistance of each  
element.  
between any two terminals ........... 30 V  
Accuracy  
With the 150 mW limit, you can power full and half bridges as  
follows:  
Error1  
Percent of Reading  
0.20%  
Percent of Range2  
0.25%  
• Four 350 Ω half bridges at 5.0 V  
• Four 350 Ω full bridges at 3.3 V  
• Four 120 Ω half bridges at 2.5 V  
Calibrated max (-40 to 70 °C)  
Calibrated typ (25 °C, 5 °C)  
Uncalibrated max (-40 to 70 °C)  
Uncalibrated typ (25 °C, 5 °C)  
0.05%  
0.60%  
0.20%  
0.05%  
0.35%  
0.1%  
If you need an excitation voltage greater than 150 mW, use the  
four-position external excitation voltage connector to connect an  
external excitation source to the USB-9237.  
1 Excluding offset null or shunt calibration. 2 Range equals 25 mV/V.  
Gain drift ............................................. 10 ppm/°C max  
Offset drift  
Channel Signal Names  
2.5 V excitation............................... 0.6 μV/V per °C  
3.3 V excitation............................... 0.5 μV/V per °C  
5 V excitation.................................. 0.3 μV/V per °C  
10 V excitation................................ 0.2 μV/V per °C  
RJ50 (10p10c) Modular Plug and RJ50 RJ45 Signal  
Receptacle Pin Numbers  
Pin Pin Name  
Signal Description  
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
SC  
AI+  
AI-  
RS+  
RS-  
EX+  
EX-  
T+  
Shunt calibration  
Positive input signal  
Negative input signal  
Positive remote sense signal  
Negative remote sense signal  
Positive excitation signal1  
Negative excitation signal1  
TEDS DATA  
Safety  
Safety Voltages  
Connect only voltages that are within these limits.  
Between any two terminals ............... 30 V max  
T-  
SC  
TEDS Return1  
Shunt calibration  
10  
Isolation  
1 These signals are shared by all four RJ50 connectors on the USB-9237.  
Channel-to-channel............................. No isolation between channels  
Channel-to-earth ground  
Continuous...................................... 60 VDC, Measurement Category I  
Withstand ....................................... 1,000 Vrms, verified by a 5 s  
dielectric withstand test  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
2
Strain- and Bridge-Based Measurements  
Accessories  
Ordering Information  
NI USB-9237 (carrier, module, and USB cable) ....................780137-01  
NI 9945 (1/4 bridge, 350 Ω, qty 4) ......................................194739-01  
NI 9944 (1/4 bridge, 120 Ω, qty 4) ......................................194738-01  
NI 9949 (RJ50 to screw terminal) ........................................196809-01  
NI 9942 (excitation connector)..............................................194611-01  
RJ50 cable, 2 m (qty 4)..........................................................194612-02  
RJ50 cable, 10 m (qty 1)........................................................194612-10  
RJ50 to signal wire cable, 2 m (qty 4)..................................195950-02  
RJ50 to signal wire cable, 10 m (qty 1)................................195950-10  
There are several options for connecting signals to the USB-9237, as  
shown in figures 1 and 2.  
BUY NOW!  
For complete product specifications, pricing, and accessory  
information, call 800 813 3693 (U.S.) or go to ni.com/compactdaq.  
Figure 1. NI 9237 with RJ50 to 10 m Signal Wire Cable  
Figure 2. NI 9237 with RJ50 Cable and Screw-Terminal Accessories  
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)  
3
NI Services and Support  
NI has the services and support to meet  
Local Sales and Technical Support  
your needs around the globe and through  
the application life cycle – from planning  
and development through deployment  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
In offices worldwide, our staff is local to the country, giving you access  
to engineers who speak your language. NI delivers industry-leading  
technical support through online knowledge bases, our applications  
engineers, and access to 14,000 measurement and automation  
professionals within NI Developer Exchange forums. Find immediate  
answers to your questions at ni.com/support.  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of technical  
support. Visit ni.com/ssp.  
Training and Certification  
NI training is the fastest, most certain route to productivity with our  
products. NI training can shorten your learning curve, save development  
time, and reduce maintenance costs over the application life cycle. We  
schedule instructor-led courses in cities worldwide, or we can hold a  
course at your facility. We also offer a professional certification program  
Hardware Services  
NI Factory Installation Services  
NI Factory Installation Services (FIS) is the fastest and easiest way to  
use your PXI or PXI/SCXI combination systems right out of the box.  
that identifies individuals who have high levels of skill and knowledge on Trained NI technicians install the software and hardware and configure  
using NI products. Visit ni.com/training.  
the system to your specifications. NI extends the standard warranty by  
one year on hardware components (controllers, chassis, modules)  
purchased with FIS. To use FIS, simply configure your system online  
with ni.com/pxiadvisor.  
Professional Services  
Our NI Professional Services team is composed of NI applications  
and systems engineers and a worldwide National Instruments Alliance  
Partner program of more than 600 independent consultants and  
integrators. Services range  
Calibration Services  
NI recognizes the need to maintain properly calibrated devices for  
high-accuracy measurements. We provide manual calibration  
procedures, services to recalibrate your products, and automated  
calibration software specifically designed for use by metrology  
laboratories. Visit ni.com/calibration.  
from start-up assistance to  
turnkey system integration.  
Visit ni.com/alliance.  
OEM Support  
We offer design-in consulting and product integration assistance if you  
want to use our products for OEM applications. For information about  
special pricing and services for OEM customers, visit ni.com/oem.  
Repair and Extended Warranty  
NI provides complete repair services for our products. Express repair  
and advance replacement services are also available. We offer  
extended warranties to help you meet project life-cycle requirements.  
Visit ni.com/services.  
ni.com • 800 813 3693  
*351510A-01*  
351510A-01  
2007-9107-301-101-D  
National Instruments • info@ni.com  
© 2007 National Instruments Corporation. All rights reserved. CVI, LabVIEW, Measurement Studio, National Instruments, National Instruments Alliance Partner, NI, ni.com, SCXI, and  
SignalExpress are trademarks of National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Other product and company names listed are  
trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from National Instruments and has no agency,  
partnership, or joint-venture relationship with National Instruments.  

相关型号:

USB-9421

Portable USB-Based High-Voltage Digital I/O
NI

USB-9472

Portable USB-Based High-Voltage Digital I/O
NI

USB-9481

Portable USB-Based High-Voltage Digital I/O
NI

USB-9AB-080-28N-MO1

Interconnection Device
ITT

USB-9AB-080-28S-MO1

Interconnection Device
ITT

USB-9AB-130-26S-MO1

Interconnection Device
ITT

USB-9AB-200-24S-MO1

Interconnection Device
ITT

USB-9AB-300-22N-MO1

Interconnection Device
ITT

USB-9AB-300-22S-MO1

Interconnection Device
ITT

USB-9AB-500-20N-MO1

Interconnection Device
ITT

USB-9AO-080-28N-MO1

Interconnection Device
ITT

USB-9AO-080-28S-MO1

Interconnection Device
ITT