PC28F640P30B85B [NUMONYX]
Flash, 4MX16, 88ns, PBGA64, LEAD FREE, BGA-64;型号: | PC28F640P30B85B |
厂家: | NUMONYX B.V |
描述: | Flash, 4MX16, 88ns, PBGA64, LEAD FREE, BGA-64 内存集成电路 闪存 |
文件: | 总96页 (文件大小:1234K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
Numonyx™ StrataFlash Embedded Memory
(P30)
Datasheet
Product Features
High performance
Security
— One-Time Programmable Registers:
— 85 ns initial access
• 64 unique factory device identifier bits
• 2112 user-programmable OTP bits
— Selectable OTP Space in Main Array:
• Four pre-defined 128-KByte blocks (top or bottom
configuration)
— 52 MHz with zero wait states, 17ns clock-to-data output
synchronous-burst read mode
— 25 ns asynchronous-page read mode
— 4-, 8-, 16-, and continuous-word burst mode
— Buffered Enhanced Factory Programming (BEFP) at 5 μs/
byte (Typ)
• Up to Full Array OTP Lockout
— Absolute write protection: V = V
PP
SS
— 1.8 V buffered programming at 7 μs/byte (Typ)
— Power-transition erase/program lockout
— Individual zero-latency block locking
— Individual block lock-down
Architecture
— Multi-Level Cell Technology: Highest Density at Lowest
Cost
Software
— Asymmetrically-blocked architecture
— Four 32-KByte parameter blocks: top or bottom
configuration
— 20 μs (Typ) program suspend
— 20 μs (Typ) erase suspend
— Numonyx™ Flash Data Integrator optimized
— Basic Command Set and Extended Command Set
compatible
— 128-KByte main blocks
Voltage and Power
— V (core) voltage: 1.7 V – 2.0 V
CC
— Common Flash Interface capable
— V
(I/O) voltage: 1.7 V – 3.6 V
CCQ
Density and Packaging
— Standby current: 20μA (Typ) for 64-Mbit
— 4-Word synchronous read current:
13 mA (Typ) at 40 MHz
— 56- Lead TSOP package (64, 128, 256,
512- Mbit)
— 64- Ball Numonyx™ Easy BGA package (64,
128, 256, 512- Mbit)
— Numonyx™ QUAD+ SCSP (64, 128, 256,
512- Mbit)
Quality and Reliability
— Operating temperature: –40 °C to +85 °C
— Minimum 100,000 erase cycles per block
— ETOX™ VIII process technology
— 16-bit wide data bus
306666-12
August 2008
Legal Lines and Disclaimers
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH NUMONYX™ PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR
OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN NUMONYX'S TERMS AND
CONDITIONS OF SALE FOR SUCH PRODUCTS, NUMONYX ASSUMES NO LIABILITY WHATSOEVER, AND NUMONYX DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY, RELATING TO SALE AND/OR USE OF NUMONYX PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Numonyx
products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.
Numonyx B.V. may make changes to specifications and product descriptions at any time, without notice.
Numonyx B.V. may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented
subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or
otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights.
Designers must not rely on the absence or characteristics of any features or instructions marked “reserved” or “undefined.” Numonyx reserves these for
future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.
Contact your local Numonyx sales office or your distributor to obtain the latest specifications and before placing your product order.
Copies of documents which have an order number and are referenced in this document, or other Numonyx literature may be obtained by visiting
Numonyx's website at http://www.numonyx.com.
Numonyx, the Numonyx logo, and StrataFlash are trademarks or registered trademarks of Numonyx B.V. or its subsidiaries in other countries.
*Other names and brands may be claimed as the property of others.
Copyright © 2008, Numonyx, B.V., All Rights Reserved.
Datasheet
2
August 2008
306666-12
P30
Contents
1.0 Functional Description...............................................................................................5
1.1
1.2
1.3
1.4
Introduction .......................................................................................................5
Overview ...........................................................................................................5
Virtual Chip Enable Description..............................................................................6
Memory Maps .....................................................................................................6
2.0 Package Information.................................................................................................9
2.1
2.2
2.3
56-Lead TSOP.....................................................................................................9
64-Ball Easy BGA Package.................................................................................. 10
QUAD+ SCSP Packages...................................................................................... 12
3.0 Ballouts................................................................................................................... 15
4.0 Signals .................................................................................................................... 18
4.1
Dual-Die Configurations ..................................................................................... 20
5.0 Bus Operations........................................................................................................21
5.1
5.2
5.3
5.4
5.5
Reads..............................................................................................................21
Writes..............................................................................................................21
Output Disable.................................................................................................. 21
Standby........................................................................................................... 22
Reset...............................................................................................................22
6.0 Command Set.......................................................................................................... 23
6.1
6.2
Device Command Codes..................................................................................... 23
Device Command Bus Cycles .............................................................................. 24
7.0 Read Operation........................................................................................................26
7.1
7.2
7.3
7.4
Asynchronous Page-Mode Read........................................................................... 26
Synchronous Burst-Mode Read............................................................................ 26
Read Device Identifier........................................................................................27
Read CFI.......................................................................................................... 27
8.0 Program Operation.................................................................................................. 28
8.1
8.2
8.3
8.4
Word Programming ........................................................................................... 28
Factory Word Programming ................................................................................29
Buffered Programming.......................................................................................29
Buffered Enhanced Factory Programming.............................................................. 30
8.4.1 BEFP Requirements and Considerations..................................................... 30
8.4.2 BEFP Setup Phase .................................................................................. 31
8.4.3 BEFP Program/Verify Phase ..................................................................... 31
8.4.4 BEFP Exit Phase ..................................................................................... 32
Program Suspend.............................................................................................. 32
Program Resume...............................................................................................32
Program Protection............................................................................................ 33
8.5
8.6
8.7
9.0 Erase Operations ..................................................................................................... 34
9.1
9.2
9.3
9.4
Block Erase ......................................................................................................34
Erase Suspend.................................................................................................. 34
Erase Resume................................................................................................... 35
Erase Protection................................................................................................35
10.0 Security Modes........................................................................................................36
10.1 Block Locking.................................................................................................... 36
10.1.1 Lock Block............................................................................................. 36
10.1.2 Unlock Block.......................................................................................... 36
August 2008
306666-12
Datasheet
3
P30
10.1.3 Lock-Down Block ....................................................................................36
10.1.4 Block Lock Status ...................................................................................37
10.1.5 Block Locking During Suspend..................................................................37
10.2 Selectable One-Time Programmable Blocks ...........................................................38
11.0 Registers .................................................................................................................39
11.1 Read Status Register..........................................................................................39
11.1.1 Clear Status Register ..............................................................................40
11.2 Read Configuration Register................................................................................40
11.2.1 Read Mode.............................................................................................41
11.2.2 Latency Count........................................................................................41
11.2.3 WAIT Polarity.........................................................................................43
11.2.4 Data Hold ..............................................................................................44
11.2.5 WAIT Delay............................................................................................44
11.2.6 Burst Sequence......................................................................................45
11.2.7 Clock Edge.............................................................................................45
11.2.8 Burst Wrap ............................................................................................46
11.2.9 Burst Length..........................................................................................46
11.2.10End of Word Line (EOWL) Considerations ...................................................46
11.3 One-Time-Programmable (OTP) Registers .............................................................46
11.3.1 Reading the OTP registers........................................................................47
11.3.2 Programming the OTP Registers................................................................48
11.3.3 Locking the OTP Registers........................................................................48
12.0 Power and Reset Specifications ...............................................................................49
12.1 Power-Up and Power-Down.................................................................................49
12.2 Reset Specifications ...........................................................................................49
12.3 Power Supply Decoupling....................................................................................50
13.0 Maximum Ratings and Operating Conditions ............................................................51
13.1 Absolute Maximum Ratings .................................................................................51
13.2 Operating Conditions..........................................................................................51
14.0 Electrical Specifications ...........................................................................................52
14.1 DC Current Characteristics..................................................................................52
14.2 DC Voltage Characteristics..................................................................................53
15.0 AC Characteristics....................................................................................................54
15.1 AC Test Conditions.............................................................................................54
15.2 Capacitance ......................................................................................................55
15.3 AC Read Specifications .......................................................................................55
15.4 AC Write Specifications.......................................................................................62
16.0 Program and Erase Characteristics...........................................................................66
17.0 Ordering Information...............................................................................................67
17.1 Discrete Products...............................................................................................67
17.2 SCSP Products...................................................................................................68
A
B
C
Supplemental Reference Information.......................................................................69
Conventions - Additional Information ......................................................................94
Revision History.......................................................................................................96
Datasheet
4
August 2008
306666-12
P30
1.0
Functional Description
1.1
Introduction
This document provides information about the Numonyx™ StrataFlash® Embedded
Memory (P30) product and describes its features, operation, and specifications.
The Numonyx™ StrataFlash® Embedded Memory (P30) product is the latest generation
of Numonyx™ StrataFlash® memory devices. Offered in 64-Mbit up through 512-Mbit
densities, the P30 device brings reliable, two-bit-per-cell storage technology to the
embedded flash market segment. Benefits include more density in less space, high-
speed interface, lowest cost-per-bit NOR device, and support for code and data
storage. Features include high-performance synchronous-burst read mode, fast
asynchronous access times, low power, flexible security options, and three industry
standard package choices. The P30 product family is manufactured using Intel* 130 nm
ETOX™ VIII process technology.
The P30 product family is also planned on the Intel* 65nm process lithography. 65nm
AC timing changes are noted in this datasheet, and should be taken into account for all
new designs.
1.2
Overview
This section provides an overview of the features and capabilities of the P30.
The P30 family provides density upgrades from 64-Mbit through 512-Mbit. This family
of devices provides high performance at low voltage on a 16-bit data bus. Individually
erasable memory blocks are sized for optimum code and data storage.
Upon initial power up or return from reset, the device defaults to asynchronous page-
mode read. Configuring the Read Configuration Register enables synchronous burst-
mode reads. In synchronous burst mode, output data is synchronized with a user-
supplied clock signal. A WAIT signal provides an easy CPU-to-flash memory
synchronization.
In addition to the enhanced architecture and interface, the device incorporates
technology that enables fast factory program and erase operations. Designed for low-
voltage systems, the
P30 supports read operations with VCC at 1.8 V, and erase and program operations with
VPP at 1.8 V or 9.0 V. Buffered Enhanced Factory Programming (BEFP) provides the
fastest flash array programming performance with VPP at 9.0 V, which increases factory
throughput. With VPP at 1.8 V, VCC and VPP can be tied together for a simple, ultra low
power design. In addition to voltage flexibility, a dedicated VPP connection provides
complete data protection when VPP ≤ VPPLK
.
A Command User Interface (CUI) is the interface between the system processor and all
internal operations of the device. An internal Write State Machine (WSM) automatically
executes the algorithms and timings necessary for block erase and program. A Status
Register indicates erase or program completion and any errors that may have occurred.
An industry-standard command sequence invokes program and erase automation. Each
erase operation erases one block. The Erase Suspend feature allows system software to
pause an erase cycle to read or program data in another block. Program Suspend
allows system software to pause programming to read other locations. Data is
programmed in word increments (16 bits).
August 2008
Order Number: 306666-12
Datasheet
5
P30
The P30 protection register allows unique flash device identification that can be used to
increase system security. The individual Block Lock feature provides zero-latency block
locking and unlocking. In addition, the P30 device also has four pre-defined spaces in
the main array that can be configured as One-Time Programmable (OTP).
1.3
Virtual Chip Enable Description
The P30 512Mbit devices employ a Virtual Chip Enable which combines two 256-Mbit
die with a common chip enable, F1-CE# for QUAD+ packages or CE# for Easy BGA and
TSOP packages. (Refer to Figure 9 on page 20 and Figure 10 on page 20). Address A24
(Quad+ package) or A25 (Easy BGA and TSOP packages) is then used to select
between the die pair with F1-CE# / CE# asserted depending upon the package option
used. When chip enable is asserted and QUAD+ A24 (Easy BGA/TSOP A25) is low (VIL),
The lower parameter die is selected; when chip enable is asserted and QUAD+ A24
(Easy BGA/TSOP A25) is high (VIH), the upper parameter die is selected. Refer to
Table 1 and Table 2 for additional details.
Table 1:
Virtual Chip Enable Truth Table for 512 Mb (QUAD+ Package)
Die Selected
F1-CE#
A24
Lower Param Die
Upper Param Die
L
L
L
H
Table 2:
Virtual Chip Enable Truth Table for 512 Mb (Easy BGA & TSOP Packages)
Die Selected
CE#
A25
Lower Param Die
Upper Param Die
L
L
L
H
1.4
Memory Maps
Table 3 through Table 5 show the P30 memory maps. The memory array is divided into
multiple 8-Mbit Programming Regions (see Section 8.0, “Program Operation” on
page 28).
Table 3:
Discrete Top Parameter Memory Maps (all packages)
Size
(KB)
Size
(KB)
Blk
64-Mbit
Blk
128-Mbit
32
66
3FC000 - 3FFFFF
32
130
7FC000 - 7FFFFF
32
63
62
3F0000 - 3F3FFF
3E0000 - 3EFFFF
32
127
126
7F0000 - 7F3FFF
7E0000 - 7EFFFF
128
128
128
56
380000 - 38FFFF
128
120
780000 - 78FFFF
Datasheet
6
August 2008
306666-12
P30
Table 3:
Discrete Top Parameter Memory Maps (all packages)
Size
(KB)
Size
(KB)
Blk
64-Mbit
Blk
128-Mbit
128
128
55
54
370000 - 37FFFF
360000 - 36FFFF
128
128
119
118
770000 - 77FFFF
760000 - 76FFFF
128
128
1
0
010000 - 01FFFF
000000 - 00FFFF
128
128
1
0
010000 - 01FFFF
000000 - 00FFFF
Size
(KB)
Blk
256-Mbit
32
258
FFC000 - FFFFFF
32
255
254
FF0000 - FF3FFF
FE0000 - FEFFFF
128
128
128
128
248
247
246
F80000 - F8FFFF
F70000 - F7FFFF
F60000 - F6FFFF
128
128
1
0
010000 - 01FFFF
000000 - 00FFFF
Table 4:
Discrete Bottom Parameter Memory Maps (all packages)
Size
(KB)
Size
(KB)
Blk
64-Mbit
Blk
128-Mbit
128
128
66
65
3F0000 - 3FFFFF
3E0000 - 3EFFFF
128
128
130
129
7F0000 - 7FFFFF
7E0000 - 7EFFFF
128
128
128
12
11
10
090000 - 09FFFF
080000 - 08FFFF
070000 - 07FFFF
128
128
128
12
11
10
090000 - 09FFFF
080000 - 08FFFF
070000 - 07FFFF
128
32
4
3
010000 - 01FFFF
00C000 - 00FFFF
128
32
4
3
010000 - 01FFFF
00C000 - 00FFFF
32
0
000000 - 003FFF
32
0
000000 - 003FFF
Size
(KB)
Blk
256-Mbit
August 2008
Order Number: 306666-12
Datasheet
7
P30
Table 4:
Discrete Bottom Parameter Memory Maps (all packages)
Size
(KB)
Size
(KB)
Blk
64-Mbit
Blk
128-Mbit
128
128
258
257
FF0000 - FFFFFF
FE0000 - FEFFFF
128
128
128
12
11
10
090000 - 09FFFF
080000 - 08FFFF
070000 - 07FFFF
128
32
4
3
010000 - 01FFFF
00C000 - 00FFFF
32
0
000000 - 003FFF
Block size is referenced in K-Bytes where a byte=8 bits. Block Address range is referenced in K-
Words where a Word is the size of the flash output bus (16 bits).
Note: The Dual- Die P30 memory maps are the same for both parameter options because the
devices employ virtual chip enable (Refer to Section 1.3). The parameter option only defines
the placement of bottom parameter die.
Table 5:
512-Mbit Top and Bottom Parameter Memory Map (Easy BGA and QUAD+ SCSP)
512-Mbit Flash (2x256-Mbit w/ 1CE)
Size
(KB)
Die Stack Config
Blk
Address Range
32
517
1FFC000 - 1FFFFFF
256-Mbit
32
514
513
1FF0000 - 1FF3FFF
1FE0000 - 1FEFFFF
Top Parameter Die
128
128
128
259
258
1000000 - 100FFFF
FF0000 - FFFFFF
256-Mbit
128
32
4
3
010000 - 01FFFF
00C000 - 00FFFF
Bottom Parameter Die
32
0
000000 - 003FFF
Note: Refer to the appropriate 256-Mbit Memory Map (Table 3 or Table 4) for Programming Region information; Block size
is referenced in K-Bytes where a byte=8 bits. Block Address range is referenced in K-Words where a Word is the size of
the flash output bus (16 bits).
Datasheet
8
August 2008
306666-12
P30
2.0
Package Information
2.1
56-Lead TSOP
Figure 1: TSOP Mechanical Specifications
Z
A
2
See Note 2
See Notes 1 and 3
Pin 1
e
See Detail B
E
Y
D
1
A
1
D
Seating
Plane
See Detail A
A
Detail A
Detail B
C
0
b
L
Table 6:
TSOP Package Dimensions (Sheet 1 of 2)
Millimeters
Nom
Inches
Nom
Product Information
Symbol
Notes
Min
Max
Min
Max
Package Height
Standoff
A
A1
A2
b
-
-
1.200
-
-
-
0.047
-
0.050
0.965
0.100
0.100
18.200
13.800
-
-
0.002
0.038
0.004
0.004
0.717
0.543
-
-
Package Body Thickness
Lead Width
0.995
0.150
0.150
18.400
14.000
0.500
20.00
1.025
0.200
0.200
18.600
14.200
-
0.039
0.006
0.006
0.724
0.551
0.0197
0.787
0.040
0.008
0.008
0.732
0.559
-
Lead Thickness
Package Body Length
Package Body Width
Lead Pitch
c
D1
E
e
Terminal Dimension
D
19.800
20.200
0.780
0.795
August 2008
Order Number: 306666-12
Datasheet
9
P30
Table 6:
TSOP Package Dimensions (Sheet 2 of 2)
Millimeters
Inches
Nom
Product Information
Symbol
Notes
Min
Nom
Max
Min
Max
Lead Tip Length
Lead Count
L
N
ý
0.500
0.600
56
0.700
-
0.020
0.024
56
0.028
-
-
0°
-
0°
Lead Tip Angle
3°
5°
3°
5°
Seating Plane Coplanarity
Lead to Package Offset
Notes:
Y
Z
-
-
0.100
0.350
-
-
0.004
0.014
0.150
0.250
0.006
0.010
1.
2.
3.
4.
One dimple on package denotes Pin 1.
If two dimples, then the larger dimple denotes Pin 1.
Pin 1 will always be in the upper left corner of the package, in reference to the product mark.
Daisy Chain Evaluation Unit information is at Numonyx™ Flash Memory Packaging Technology
http://developer.Numonyx.com/design/flash/packtech.
2.2
64-Ball Easy BGA Package
Figure 2: Easy BGA Mechanical Specifications
Ball A1
Corner
Ball A1
Corner
D
S1
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
S2
A
B
C
D
E
F
A
B
C
D
E
F
b
e
E
G
H
G
H
Top View - Ball side down
A1
Bottom View - Ball Side Up
A2
A
Seating
Plane
Y
Note: Drawing not to scale
Datasheet
10
August 2008
306666-12
P30
Table 7:
Easy BGA Package Dimensions
Millimeters
Nom
Inches
Nom
Product Information
Symbol
Notes
Min
Max
Min
Max
Package Height (64/128/256-Mbit)
Package Height (512-Mbit)
Ball Height
A
A
-
-
-
-
-
1.200
1.300
-
-
-
-
-
-
0.0472
0.0512
-
A1
0.250
0.0098
Package Body Thickness (64/128/256-
Mbit)
A2
-
0.780
-
-
0.0307
-
Package Body Thickness (512-Mbit)
Ball (Lead) Width
A2
b
-
0.330
9.900
12.900
-
0.910
0.430
10.000
13.000
1.000
64
-
-
0.0358
0.0169
0.3937
0.5118
0.0394
64
-
0.530
10.100
13.100
-
0.0130
0.3898
0.5079
-
0.0209
0.3976
0.5157
-
Package Body Width
Package Body Length
Pitch
D
E
[e]
N
Ball (Lead) Count
-
-
-
-
Seating Plane Coplanarity
Corner to Ball A1 Distance Along D
Corner to Ball A1 Distance Along E
Notes:
Y
-
-
0.100
1.600
3.100
-
-
0.0039
0.0630
0.1220
S1
S2
1.400
2.900
1.500
3.000
0.0551
0.1142
0.0591
0.1181
1.
Daisy Chain Evaluation Unit information is at Numonyx™ Flash Memory Packaging Technology
http://developer.Numonyx.com/design/flash/packtech.
August 2008
Order Number: 306666-12
Datasheet
11
P30
2.3
QUAD+ SCSP Packages
Figure 3: 64/128-Mbit, 88-ball (80 active) QUAD+ SCSP Specifications (8x10x1.2 mm)
A1 Index
Mark
S1
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
S2
A
B
C
D
E
F
A
B
C
D
E
F
D
e
G
G
H
J
H
J
K
K
L
L
M
M
b
E
Top View - Ball
Down
Bottom View - Ball Up
A
A2
A1
Y
Drawing not to scale.
Millimeters
Nom
-
Inches
Nom
-
Dimens ions
Package Height
Ball Height
Package Body Thickness
Ball (Lead) Width
Package Body Width
Package Body Length
Pitch
Ball (Lead) Count
Seating Plane Coplanarity
Corner to Ball A1 Distance Along E
Corner to Ball A1 Distance Along D
S ymbol
A
Min
-
0.200
-
0.325
9.900
7.900
-
Max
1.200
-
Min
-
Max
0.0472
-
1
A
A
-
0.0079
-
0.0128
0.3898
0.3110
-
-
2
0.860
0.375
10.000
8.000
0.800
88
-
0.0339
0.0148
0.3937
0.3150
0.0315
88
-
b
D
E
e
N
Y
0.425
10.100
8.100
-
0.0167
0.3976
0.3189
-
-
-
-
-
-
-
-
0.100
1.300
0.700
-
0.0039
0.0512
0.0276
1
S
S
1.100
0.500
1.200
0.600
0.0433
0.0197
0.0472
0.0236
2
Datasheet
12
August 2008
306666-12
P30
Figure 4: 256-Mbit, 88-ball (80 active) QUAD+ SCSP Specifications (8x11x1.0 mm)
S1
A1 Index
Mark
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
S2
A
B
C
D
E
F
A
B
C
D
E
F
D
e
G
G
H
J
H
J
K
K
L
L
M
M
b
E
Bottom View - Ball Up
A
Top View - Ball Down
A2
A1
Y
Drawing not to scale.
Note: Dimensions A1, A2, and b are preliminary
Millimeters
Inches
Dimensions
Package Height
Ball Height
Package Body Thickness
Ball (Lead) Width
Package Body Length
Package Body Width
Pitch
Symbol
Min
Nom
-
-
0.740
0.350
11.00
8.00
0.80
88
Max
1.000
-
Min
-
Nom
-
-
0.0291
0.0138
0.4331
0.3150
0.0315
88
Max
0.0394
-
A
A1
A2
b
D
E
-
0.117
-
0.300
10.900
7.900
-
0.0046
-
0.0118
0.4291
0.3110
-
-
-
0.400
11.100
8.100
-
0.0157
0.4370
0.3189
-
e
N
Ball (Lead) Count
-
-
-
-
Seating Plane Coplanarity
Corner to Ball A1 Distance Along E
Corner to Ball A1 Distance Along D
Y
S1
S2
-
-
0.100
1.300
1.200
-
-
0.0039
0.0512
0.0472
1.100
1.000
1.200
1.100
0.0433
0.0394
0.0472
0.0433
August 2008
Order Number: 306666-12
Datasheet
13
P30
Figure 5: 512-Mbit, 88-ball (80 active) QUAD+ SCSP Specifications (8x11x1.2 mm)
S1
A1 Index
Mark
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
S2
A
B
C
D
E
F
A
B
C
D
E
F
D
e
G
G
H
J
H
J
K
K
L
L
M
M
b
E
Bottom View - Ball Up
A
Top View - Ball Down
A2
A1
Y
Drawing not to scale.
Millimeters
Nom
-
Inches
Nom
-
Dimensions
Package Height
Ball Height
Package Body Thickness
Ball (Lead) Width
Package Body Length
Package Body Width
Pitch
Symbol
Min
Max
1.200
-
Min
-
Max
0.0472
-
A
A1
A2
b
D
E
-
0.200
-
0.325
10.900
7.900
-
-
0.0079
-
0.0128
0.4291
0.3110
-
-
0.860
0.375
11.000
8.000
0.800
88
-
0.0339
0.0148
0.4331
0.3150
0.0315
88
-
0.425
11.100
8.100
-
0.0167
0.4370
0.3189
-
e
N
Ball (Lead) Count
-
-
-
-
Seating Plane Coplanarity
Corner to Ball A1 Distance Along E
Corner to Ball A1 Distance Along D
Y
S1
S2
-
-
0.100
1.300
1.200
-
-
0.0039
0.0512
0.0472
1.100
1.000
1.200
1.100
0.0433
0.0394
0.0472
0.0433
Datasheet
14
August 2008
306666-12
P30
3.0
Ballouts
Figure 6: 56-Lead TSOP Pinout (64/128/256/512- Mbit)
WAIT
A17
56
55
54
53
52
51
50
49
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
1
2
3
4
5
6
7
8
A16
A15
DQ15
DQ7
DQ14
DQ6
DQ13
DQ5
DQ12
DQ4
ADV#
CLK
A14
A13
A12
A11
A10
A9
A23
A22
A21
VSS
VCC
WE#
WP#
A20
A19
A18
A8
A7
A6
A5
A4
A3
A2
A24
A25
VSS
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Intel StrataFlash®
Embedded Memory (P30)
RST#
VPP
56-Lead TSOP Pinout
14 mm x 20 mm
DQ11
DQ3
DQ10
DQ2
VCCQ
DQ9
DQ1
DQ8
DQ0
VCC
OE#
Top View
VSS
CE#
A1
Notes:
1.
2.
3.
4.
5.
A1 is the least significant address bit.
A23 is valid for 128-Mbit densities and above; otherwise, it is a no connect (NC).
A24 is valid for 256-Mbit densities; otherwise, it is a no connect (NC).
A25 is valid for 512-Mbit densities; otherwise, it is a no connect (NC).
Please refer to the latest specification update for synchronous read operation with the TSOP package. The synchronous read
input signals (i.e. ADV# and CLK) should be tied off to support asynchronous reads. See Section 4.0, “Signals” on page 18.
August 2008
Order Number: 306666-12
Datasheet
15
P30
Figure 7: 64-Ball Easy BGA Ballout (64/128/256/512-Mbit)
5
8
8
5
1
2
3
4
6
7
7
6
4
3
2
1
A
B
C
D
A
B
C
D
E
A1
A6
A8
VPP A13 VCC A18 A22
A22 A18 VCC A13 VPP A8
RFU A19 A25 A14 CE# A9
A21 A20 WP# A15 A12 A10
A17 A16 VCCQ VCCQ RST# A11
A6
VSS
A7
A1
A2
A3
A4
A2 VSS
A9 CE# A14 A25 A19 RFU
A10 A12 A15 WP# A20 A21
A11 RST# VCCQ VCCQ A16 A17
A3
A4
A7
A5
A5
E
F
DQ8 DQ1 DQ9 DQ3 DQ4 CLK DQ15 RFU
RFU DQ0 DQ10 DQ11 DQ12 ADV# WAIT OE#
A23 RFU DQ2 VCCQ DQ5 DQ6 DQ14 WE#
RFU DQ15 CLK DQ4 DQ3 DQ9 DQ1 DQ8
OE# WAIT ADV# DQ12 DQ11 DQ10 DQ0 RFU
WE# DQ14 DQ6 DQ5 VCCQ DQ2 RFU A23
F
G
G
H
H
RFU VSS VCC VSS DQ13 VSS DQ7 A24
A24 DQ7 VSS DQ13 VSS VCC VSS RFU
Easy BGA
Easy BGA
Top View- Ball side down
Bottom View- Ball side up
Notes:
1.
2.
3.
4.
A1 is the least significant address bit.
A23 is valid for 128-Mbit densities and above; otherwise, it is a no connect (NC).
A24 is valid for 256-Mbit densities and above; otherwise, it is a no connect (NC).
A25 is valid for 512-Mbit densities; otherwise, it is a no connect (NC).
Datasheet
16
August 2008
306666-12
P30
Figure 8: 88-Ball (80-Active Ball) QUAD+ SCSP Ballout
Pin 1
1
DU
A4
A5
A3
A2
A1
A0
RFU
2
3
4
5
6
7
8
DU
DU
Depop
A19
Depop
VSS
Depop
VCC
RFU
Depop
VCC
CLK
RFU
A20
DU
A
B
C
D
E
F
A
B
C
D
E
F
A18
RFU
A17
A7
A21
A22
A9
A11
A23
VSS
A12
A24
VPP
RFU
A13
RFU
RFU
DQ2
DQ1
WP#
RST#
DQ10
DQ3
ADV#
WE#
DQ5
A10
A14
WAIT
DQ7
A15
A6
A8
A16
DQ8
DQ0
DQ13
DQ14
F2-CE#
F2-OE#
G
H
G
H
DQ12
J
K
L
RFU
F1-CE#
VSS
DU
F1-OE#
RFU
VSS
DU
DQ9
RFU
DQ11
RFU
VCC
Depop
4
DQ4
RFU
VSS
Depop
5
DQ6
VCC
VSS
Depop
6
DQ15
VCCQ
VSS
DU
VCCQ
RFU
VSS
DU
J
K
L
VCCQ
Depop
3
M
M
1
2
7
8
Notes:
1.
2.
3.
4.
A22 is valid for 128-Mbit densities and above; otherwise, it is a no connect (NC).
A23 is valid for 256-Mbit densities and above; otherwise, it is a no connect (NC).
A24 is valid for 512-Mbit densities and above; otherwise, it is a no connect (NC).
F2-CE# and F2-OE# are no connect (NC) for all densities.
August 2008
Order Number: 306666-12
Datasheet
17
P30
4.0
Signals
This section has signal descriptions for the various P30 packages.
Table 8:
TSOP and Easy BGA Signal Descriptions (Sheet 1 of 2)
Symbol
Type
Name and Function
ADDRESS INPUTS: Device address inputs. 64-Mbit: A[22:1]; 128-Mbit: A[23:1]; 256-Mbit:
A[24:1]; 512-Mbit: A[25:1]. Note: The virtual selection of the 256-Mbit “Top parameter” die in the
dual-die 512-Mbit configuration is accomplished by setting A[25] high (VIH).
A[MAX:1]
DQ[15:0]
Input
DATA INPUT/OUTPUTS: Inputs data and commands during write cycles; outputs data during
memory, Status Register, Protection Register, and Read Configuration Register reads. Data balls float
when the CE# or OE# are deasserted. Data is internally latched during writes.
Input/
Output
ADDRESS VALID: Active low input. During synchronous read operations, addresses are latched on
the rising edge of ADV#, or on the next valid CLK edge with ADV# low, whichever occurs first.
ADV#
Input
In asynchronous mode, the address is latched when ADV# going high or continuously flows through
if ADV# is held low.
WARNING: Designs not using ADV# must tie it to VSS to allow addresses to flow through.
FLASH CHIP ENABLE: Active low input. CE# low selects the associated flash memory die. When
asserted, flash internal control logic, input buffers, decoders, and sense amplifiers are active. When
deasserted, the associated flash die is deselected, power is reduced to standby levels, data and
WAIT outputs are placed in high-Z state.
CE#
CLK
Input
Input
WARNING: Chip enable must be driven high when device is not in use.
CLOCK: Synchronizes the device with the system’s bus frequency in synchronous-read mode. During
synchronous read operations, addresses are latched on the rising edge of ADV#, or on the next valid
CLK edge with ADV# low, whichever occurs first.
WARNING: Designs not using CLK for synchronous read mode must tie it to VCCQ or VSS.
OUTPUT ENABLE: Active low input. OE# low enables the device’s output data buffers during read
OE#
Input
Input
cycles. OE# high places the data outputs and WAIT in High-Z.
RESET: Active low input. RST# resets internal automation and inhibits write operations. This
provides data protection during power transitions. RST# high enables normal operation. Exit from
reset places the device in asynchronous read array mode.
RST#
WAIT: Indicates data valid in synchronous array or non-array burst reads. Read Configuration
Register bit 10 (RCR[10], WT) determines its polarity when asserted. WAIT’s active output is VOL or
VOH when CE# and OE# are VIL. WAIT is high-Z if CE# or OE# is VIH
.
WAIT
Output
•
•
In synchronous array or non-array read modes, WAIT indicates invalid data when asserted and
valid data when deasserted.
In asynchronous page mode, and all write modes, WAIT is deasserted.
WRITE ENABLE: Active low input. WE# controls writes to the device. Address and data are latched
WE#
WP#
Input
Input
on the rising edge of WE#.
WRITE PROTECT: Active low input. WP# low enables the lock-down mechanism. Blocks in lock-
down cannot be unlocked with the Unlock command. WP# high overrides the lock-down function
enabling blocks to be erased or programmed using software commands.
Erase and Program Power: A valid voltage on this pin allows erasing or programming. Memory
contents cannot be altered when VPP ≤ VPPLK. Block erase and program at invalid VPP voltages should
not be attempted.
Set VPP = VPPL for in-system program and erase operations. To accommodate resistor or diode drops
from the system supply, the VIH level of VPP can be as low as VPPL min. VPP must remain above VPPL
min to perform in-system flash modification. VPP may be 0 V during read operations.
VPPH can be applied to main blocks for 1000 cycles maximum and to parameter blocks for 2500
cycles. VPP can be connected to 9 V for a cumulative total not to exceed 80 hours. Extended use of
this pin at 9 V may reduce block cycling capability.
Power/
Input
VPP
VCC
Device Core Power Supply: Core (logic) source voltage. Writes to the flash array are inhibited
when VCC ≤ VLKO. Operations at invalid VCC voltages should not be attempted.
Power
VCCQ
VSS
Power
Power
Output Power Supply: Output-driver source voltage.
Ground: Connect to system ground. Do not float any VSS connection.
Datasheet
18
August 2008
306666-12
P30
Table 8:
TSOP and Easy BGA Signal Descriptions (Sheet 2 of 2)
Symbol
Type
Name and Function
Reserved for Future Use: Reserved by Numonyx for future device functionality and enhancement.
These should be treated in the same way as a Do Not Use (DU) signal.
RFU
—
DU
NC
—
—
Do Not Use: Do not connect to any other signal, or power supply; must be left floating.
No Connect: No internal connection; can be driven or floated.
Table 9:
QUAD+ SCSP Signal Descriptions (Sheet 1 of 2)
Symbol
Type
Name and Function
ADDRESS INPUTS: Device address inputs. 64-Mbit: A[21:0]; 128-Mbit: A[22:0]; 256-Mbit:
A[23:0]; 512-Mbit: A[24:0]. Note: The virtual selection of the 256-Mbit “Top parameter” die in the
dual-die 512-Mbit configuration is accomplished by setting A[25] high (VIH).
A[MAX:0]
DQ[15:0]
Input
DATA INPUT/OUTPUTS: Inputs data and commands during write cycles; outputs data during
memory, Status Register, Protection Register, and Read Configuration Register reads. Data balls float
when the CE# or OE# are deasserted. Data is internally latched during writes.
Input/
Output
ADDRESS VALID: Active low input. During synchronous read operations, addresses are latched on
the rising edge of ADV#, or on the next valid CLK edge with ADV# low, whichever occurs first.
ADV#
Input
In asynchronous mode, the address is latched when ADV# going high or continuously flows through
if ADV# is held low.
WARNING: Designs not using ADV# must tie it to VSS to allow addresses to flow through.
FLASH CHIP ENABLE: Active low input. CE# low selects the associated flash memory die. When
asserted, flash internal control logic, input buffers, decoders, and sense amplifiers are active. When
deasserted, the associated flash die is deselected, power is reduced to standby levels, data and
WAIT outputs are placed in high-Z state.
F1-CE#
CLK
Input
Input
WARNING: Chip enable must be driven high when device is not in use.
CLOCK: Synchronizes the device with the system’s bus frequency in synchronous-read mode. During
synchronous read operations, addresses are latched on the rising edge of ADV#, or on the next valid
CLK edge with ADV# low, whichever occurs first.
WARNING: Designs not using CLK for synchronous read mode must tie it to VCCQ or VSS.
OUTPUT ENABLE: Active low input. OE# low enables the device’s output data buffers during read
cycles. OE# high places the data outputs and WAIT in High-Z.
F1-OE#
RST#
Input
Input
RESET: Active low input. RST# resets internal automation and inhibits write operations. This
provides data protection during power transitions. RST# high enables normal operation. Exit from
reset places the device in asynchronous read array mode.
WAIT: Indicates data valid in synchronous array or non-array burst reads. Read Configuration
Register bit 10 (RCR[10], WT) determines its polarity when asserted. WAIT’s active output is VOL or
VOH when CE# and OE# are VIL. WAIT is high-Z if CE# or OE# is VIH
.
WAIT
Output
•
•
In synchronous array or non-array read modes, WAIT indicates invalid data when asserted and
valid data when deasserted.
In asynchronous page mode, and all write modes, WAIT is deasserted.
WRITE ENABLE: Active low input. WE# controls writes to the device. Address and data are latched
WE#
WP#
Input
Input
on the rising edge of WE#.
WRITE PROTECT: Active low input. WP# low enables the lock-down mechanism. Blocks in lock-
down cannot be unlocked with the Unlock command. WP# high overrides the lock-down function
enabling blocks to be erased or programmed using software commands.
Erase and Program Power: A valid voltage on this pin allows erasing or programming. Memory
contents cannot be altered when VPP ≤ VPPLK. Block erase and program at invalid VPP voltages should
not be attempted.
Set VPP = VPPL for in-system program and erase operations. To accommodate resistor or diode drops
from the system supply, the VIH level of VPP can be as low as VPPL min. VPP must remain above VPPL
min to perform in-system flash modification. VPP may be 0 V during read operations.
Power/
lnput
VPP
VPPH can be applied to main blocks for 1000 cycles maximum and to parameter blocks for 2500
cycles. VPP can be connected to 9 V for a cumulative total not to exceed 80 hours. Extended use of
this pin at 9 V may reduce block cycling capability.
August 2008
Order Number: 306666-12
Datasheet
19
P30
Table 9:
QUAD+ SCSP Signal Descriptions (Sheet 2 of 2)
Symbol
Type
Name and Function
Device Core Power Supply: Core (logic) source voltage. Writes to the flash array are inhibited
when VCC ≤ VLKO. Operations at invalid VCC voltages should not be attempted.
VCC
Power
VCCQ
VSS
Power
Power
Output Power Supply: Output-driver source voltage.
Ground: Connect to system ground. Do not float any VSS connection.
Reserved for Future Use: Reserved by Numonyx for future device functionality and enhancement.
These should be treated in the same way as a Do Not Use (DU) signal.
RFU
—
DU
NC
—
—
Do Not Use: Do not connect to any other signal, or power supply; must be left floating.
No Connect: No internal connection; can be driven or floated.
4.1
Dual-Die Configurations
Figure 9: 512-Mbit Easy BGA and TSOP Top or Bottom Parameter Block Diagram
Easy BGA & TSOP 512-Mbit (Dual-Die) Top or Bottom Parameter
Configuration
CE#
Top Param Die
RST#
WP#
OE#
WE#
(256-Mbit)
VCC
VPP
VCCQ
VSS
CLK
ADV#
Bottom Param Die
(256-Mbit)
DQ[15:0]
WAIT
A[MAX:1]
Figure 10: 512-Mbit QUAD+ SCSP Top or Bottom Parameter Block Diagram
QUAD+ 512-Mbit (Dual-Die) Top or Bottom Parameter
Configuration
F1-CE#
Top Param Die
RST#
WP#
OE#
WE#
(256-Mbit)
VCC
VPP
VCCQ
VSS
CLK
ADV#
Bottom Param Die
(256-Mbit)
DQ[15:0]
WAIT
A[MAX:0]
Note: Amax = Vih selects the Top parameter Die; Amax = Vil selects the Bottom Parameter Die.
Datasheet
20
August 2008
306666-12
P30
5.0
Bus Operations
CE# low and RST# high enable device read operations. The device internally decodes
upper address inputs to determine the accessed block. ADV# low opens the internal
address latches. OE# low activates the outputs and gates selected data onto the I/O
bus.
In asynchronous mode, the address is latched when ADV# goes high or continuously
flows through if ADV# is held low. In synchronous mode, the address is latched by the
first of either the rising ADV# edge or the next valid CLK edge with ADV# low (WE#
and RST# must be VIH; CE# must be VIL).
Bus cycles to/from the P30 device conform to standard microprocessor bus operations.
Table 10 summarizes the bus operations and the logic levels that must be applied to
the device control signal inputs.
Table 10: Bus Operations Summary
DQ[15:0
]
Bus Operation
RST#
CLK
ADV#
CE#
OE#
WE#
WAIT
Notes
Asynchronous
VIH
VIH
VIH
VIH
VIH
VIL
X
L
L
L
L
L
L
H
H
L
Output
Output
Input
Deasserted
Driven
Read
Write
Synchronous
Running
X
X
X
X
L
L
H
H
X
X
High-Z
High-Z
High-Z
High-Z
1
2
Output Disable
Standby
Reset
X
X
X
L
H
X
X
High-Z
High-Z
High-Z
H
X
2
2,3
Notes:
1.
Refer to the Table 12, “Command Bus Cycles” on page 25 for valid DQ[15:0] during a write
operation.
2.
3.
X = Don’t Care (H or L).
RST# must be at VSS ± 0.2 V to meet the maximum specified power-down current.
5.1
5.2
Reads
To perform a read operation, RST# and WE# must be deasserted while CE# and OE#
are asserted. CE# is the device-select control. When asserted, it enables the flash
memory device. OE# is the data-output control. When asserted, the addressed flash
memory data is driven onto the I/O bus.
Writes
To perform a write operation, both CE# and WE# are asserted while RST# and OE# are
deasserted. During a write operation, address and data are latched on the rising edge
of WE# or CE#, whichever occurs first. Table 12, “Command Bus Cycles” on page 25
shows the bus cycle sequence for each of the supported device commands, while
Table 11, “Command Codes and Definitions” on page 23 describes each command. See
Section 15.0, “AC Characteristics” on page 54 for signal-timing details.
Note: Write operations with invalid VCC and/or VPP voltages can produce spurious results and should
not be attempted.
5.3
Output Disable
When OE# is deasserted, device outputs DQ[15:0] are disabled and placed in a high-
impedance (High-Z) state, WAIT is also placed in High-Z.
August 2008
Order Number: 306666-12
Datasheet
21
P30
5.4
5.5
Standby
When CE# is deasserted the device is deselected and placed in standby, substantially
reducing power consumption. In standby, the data outputs are placed in High-Z,
independent of the level placed on OE#. Standby current, ICCS, is the average current
measured over any 5 ms time interval, 5 μs after CE# is deasserted. During standby,
average current is measured over the same time interval 5 μs after CE# is deasserted.
When the device is deselected (while CE# is deasserted) during a program or erase
operation, it continues to consume active power until the program or erase operation is
completed.
Reset
As with any automated device, it is important to assert RST# when the system is reset.
When the system comes out of reset, the system processor attempts to read from the
flash memory if it is the system boot device. If a CPU reset occurs with no flash
memory reset, improper CPU initialization may occur because the flash memory may
be providing status information rather than array data. Flash memory devices from
Numonyx allow proper CPU initialization following a system reset through the use of the
RST# input. RST# should be controlled by the same low-true reset signal that resets
the system CPU.
After initial power-up or reset, the device defaults to asynchronous Read Array mode,
and the Status Register is set to 0x80. Asserting RST# de-energizes all internal
circuits, and places the output drivers in High-Z. When RST# is asserted, the device
shuts down the operation in progress, a process which takes a minimum amount of
time to complete. When RST# has been deasserted, the device is reset to
asynchronous Read Array state.
Note: If RST# is asserted during a program or erase operation, the operation is terminated and the
memory contents at the aborted location (for a program) or block (for an erase) are no longer
valid, because the data may have been only partially written or erased.
When returning from a reset (RST# deasserted), a minimum wait is required before the
initial read access outputs valid data. Also, a minimum delay is required after a reset
before a write cycle can be initiated. After this wake-up interval passes, normal
operation is restored. See Section 15.0, “AC Characteristics” on page 54 for details
about signal-timing.
Datasheet
22
August 2008
306666-12
P30
6.0
Command Set
6.1
Device Command Codes
The system CPU provides control of all in-system read, write, and erase operations of
the device via the system bus. The on-chip Write State Machine (WSM) manages all
block-erase and word-program algorithms.
Device commands are written to the Command User Interface (CUI) to control all flash
memory device operations. The CUI does not occupy an addressable memory location;
it is the mechanism through which the flash device is controlled.
Table 11: Command Codes and Definitions (Sheet 1 of 2)
Mode
Code
Device Mode
Read Array
Description
0xFF
Places the device in Read Array mode. Array data is output on DQ[15:0].
Places the device in Read Status Register mode. The device enters this mode
after a program or erase command is issued. Status Register data is output
on DQ[7:0].
Read Status
Register
0x70
0x90
Read Device ID
or Configuration
Register
Places device in Read Device Identifier mode. Subsequent reads output
manufacturer/device codes, Configuration Register data, Block Lock status,
or Protection Register data on DQ[15:0].
Read
Places the device in Read CFI mode. Subsequent reads output Common Flash
Interface information on DQ[7:0].
0x98
0x50
Read CFI
Clear Status
Register
The WSM can only set Status Register error bits. The Clear Status Register
command is used to clear the SR error bits.
First cycle of a 2-cycle programming command; prepares the CUI for a write
operation. On the next write cycle, the address and data are latched and the
WSM executes the programming algorithm at the addressed location. During
program operations, the device responds only to Read Status Register and
Program Suspend commands. CE# or OE# must be toggled to update the
Status Register in asynchronous read. CE# or ADV# must be toggled to
update the Status Register Data for synchronous Non-array reads. The Read
Array command must be issued to read array data after programming has
finished.
Word Program
Setup
Write
0x40
Alternate Word
Program Setup
0x10
0xE8
Equivalent to the Word Program Setup command, 0x40.
This command loads a variable number of words up to the buffer size of 32
words onto the program buffer.
Buffered Program
The confirm command is Issued after the data streaming for writing into the
buffer is done. This instructs the WSM to perform the Buffered Program
algorithm, writing the data from the buffer to the flash memory array.
Buffered Program
Confirm
0xD0
Write
First cycle of a 2-cycle command; initiates Buffered Enhanced Factory
Program mode (BEFP). The CUI then waits for the BEFP Confirm command,
0xD0, that initiates the BEFP algorithm. All other commands are ignored
when BEFP mode begins.
0x80
0xD0
BEFP Setup
If the previous command was BEFP Setup (0x80), the CUI latches the
address and data, and prepares the device for BEFP mode.
BEFP Confirm
August 2008
Order Number: 306666-12
Datasheet
23
P30
Table 11: Command Codes and Definitions (Sheet 2 of 2)
Mode
Code
Device Mode
Description
First cycle of a 2-cycle command; prepares the CUI for a block-erase
operation. The WSM performs the erase algorithm on the block addressed by
the Erase Confirm command. If the next command is not the Erase Confirm
(0xD0) command, the CUI sets Status Register bits SR[4] and SR[5], and
places the device in read status register mode.
0x20
Block Erase Setup
Erase
If the first command was Block Erase Setup (0x20), the CUI latches the
address and data, and the WSM erases the addressed block. During block-
erase operations, the device responds only to Read Status Register and Erase
Suspend commands. CE# or OE# must be toggled to update the Status
Register in asynchronous read. CE# or ADV# must be toggled to update the
Status Register Data for synchronous Non-array reads
0xD0
0xB0
Block Erase Confirm
This command issued to any device address initiates a suspend of the
currently-executing program or block erase operation. The Status Register
indicates successful suspend operation by setting either SR[2] (program
suspended) or SR[6] (erase suspended), along with SR[7] (ready). The Write
State Machine remains in the suspend mode regardless of control signal
states (except for RST# asserted).
Program or Erase
Suspend
Suspend
This command issued to any device address resumes the suspended program
or block-erase operation.
0xD0
0x60
Suspend Resume
Lock Block Setup
First cycle of a 2-cycle command; prepares the CUI for block lock
configuration changes. If the next command is not Block Lock (0x01), Block
Unlock (0xD0), or Block Lock-Down (0x2F), the CUI sets Status Register bits
SR[4] and SR[5], indicating a command sequence error.
If the previous command was Block Lock Setup (0x60), the addressed block
is locked.
0x01
0xD0
0x2F
0xC0
Lock Block
Block Locking/
Unlocking
If the previous command was Block Lock Setup (0x60), the addressed block
is unlocked. If the addressed block is in a lock-down state, the operation has
no effect.
Unlock Block
Lock-Down Block
If the previous command was Block Lock Setup (0x60), the addressed block
is locked down.
First cycle of a 2-cycle command; prepares the device for a Protection
Register or Lock Register program operation. The second cycle latches the
register address and data, and starts the programming algorithm
Program Protection
Register Setup
Protection
First cycle of a 2-cycle command; prepares the CUI for device read
configuration. If the Set Read Configuration Register command (0x03) is not
the next command, the CUI sets Status Register bits SR[4] and SR[5],
indicating a command sequence error.
Read Configuration
Register Setup
0x60
0x03
Configuration
If the previous command was Read Configuration Register Setup (0x60), the
CUI latches the address and writes A[15:0] to the Read Configuration
Register. Following a Configure Read Configuration Register command,
subsequent read operations access array data.
Read Configuration
Register
6.2
Device Command Bus Cycles
Device operations are initiated by writing specific device commands to the Command
User Interface (CUI). Several commands are used to modify array data including Word
Program and Block Erase commands. Writing either command to the CUI initiates a
sequence of internally-timed functions that culminate in the completion of the
requested task. However, the operation can be aborted by either asserting RST# or by
issuing an appropriate suspend command.
Datasheet
24
August 2008
306666-12
P30
Table 12: Command Bus Cycles
First Bus Cycle
Second Bus Cycle
Bus
Mode
Command
Cycles
Oper
Addr(1)
Data(2)
Oper
Addr(1)
Data(2)
Read Array
1
Write
Write
DnA
DnA
0xFF
0x90
-
-
-
Read Device Identifier
Read CFI
≥ 2
Read
DBA + IA
ID
DBA + CFI-
A
Read
≥ 2
Write
DnA
0x98
Read
CFI-D
Read Status Register
Clear Status Register
2
1
Write
Write
DnA
DnA
0x70
0x50
Read
-
DnA
-
SRD
-
0x40/
0x10
Word Program
2
Write
Write
Write
WA
WA
WA
Write
Write
Write
WA
WA
WA
WD
Program
Buffered Program(3)
> 2
> 2
0xE8
0x80
N - 1
0xD0
Buffered Enhanced Factory
Program (BEFP)(4)
Erase
Block Erase
2
Write
BA
0x20
Write
BA
0xD0
Program/Erase Suspend
Program/Erase Resume
Lock Block
1
1
2
2
2
2
2
Write
Write
Write
Write
Write
Write
Write
DnA
DnA
BA
0xB0
0xD0
0x60
0x60
0x60
0xC0
0xC0
-
-
-
-
Suspend
-
-
Write
Write
Write
Write
Write
BA
0x01
0xD0
0x2F
OTP-D
LRD
Block
Locking/
Unlocking
Unlock Block
BA
BA
Lock-down Block
BA
BA
PRA
LRA
OTP-RA
LRA
Program OTP Register
Program Lock Register
OTP Register
Program Read Configuration
Register
Configuration
2
Write
RCD
0x60
Write
RCD
0x03
Notes:
1.
First command cycle address should be the same as the operation’s target address.
DBA = Device Base Address (NOTE: needed for dual-die 512 Mb device)
DnA = Address within the device.
IA = Identification code address offset.
CFI-A = Read CFI address offset.
WA = Word address of memory location to be written.
BA = Address within the block.
OTP-RA = Protection Register address.
LRA = Lock Register address.
RCD = Read Configuration Register data on QUAD+ A[15:0] or EASY BGA A[16:1].
ID = Identifier data.
CFI-D = CFI data on DQ[15:0].
2.
SRD = Status Register data.
WD = Word data.
N = Word count of data to be loaded into the write buffer.
OTP-D = Protection Register data.
LRD = Lock Register data.
3.
4.
The second cycle of the Buffered Program Command is the word count of the data to be loaded into the write buffer. This
is followed by up to 32 words of data.Then the confirm command (0xD0) is issued, triggering the array programming
operation.
The confirm command (0xD0) is followed by the buffer data.
August 2008
Order Number: 306666-12
Datasheet
25
P30
7.0
Read Operation
The device supports two read modes: asynchronous page mode and synchronous burst
mode. Asynchronous page mode is the default read mode after device power-up or a
reset. The Read Configuration Register must be configured to enable synchronous burst
reads of the flash memory array (see Section 11.2, “Read Configuration Register” on
page 40).
The device can be in any of four read states: Read Array, Read Identifier, Read Status
or Read CFI. Upon power-up, or after a reset, the device defaults to Read Array. To
change the read state, the appropriate read command must be written to the device
(see Section 6.0, “Command Set” on page 23).
7.1
Asynchronous Page-Mode Read
Following a device power-up or reset, asynchronous page mode is the default read
mode and the device is set to Read Array. However, to perform array reads after any
other device operation (e.g. write operation), the Read Array command must be issued
in order to read from the flash memory array.
Note: Asynchronous page-mode reads can only be performed when Read Configuration Register bit
RCR[15] is set (see Section 11.2, “Read Configuration Register” on page 40).
To perform an asynchronous page-mode read, an address is driven onto the Address
bus, and CE# and ADV# are asserted. WE# and RST# must already have been
deasserted. WAIT is deasserted during asynchronous page mode. ADV# can be driven
high to latch the address, or it must be held low throughout the read cycle. CLK is not
used for asynchronous page-mode reads, and is ignored. If only asynchronous reads
are to be performed, CLK should be tied to a valid VIH level, WAIT signal can be floated
and ADV# must be tied to ground. Array data is driven onto DQ[15:0] after an initial
access time tAVQV delay. (see Section 15.0, “AC Characteristics” on page 54).
In asynchronous page mode, four data words are “sensed” simultaneously from the flash
memory array and loaded into an internal page buffer. The buffer word corresponding
to the initial address on the Address bus is driven onto DQ[15:0] after the initial access
delay. The lowest two address bits determine which word of the 4-word page is output
from the data buffer at any given time.
7.2
Synchronous Burst-Mode Read
To perform a synchronous burst-read, an initial address is driven onto the Address bus,
and CE# and ADV# are asserted. WE# and RST# must already have been deasserted.
ADV# is asserted, and then deasserted to latch the address. Alternately, ADV# can
remain asserted throughout the burst access, in which case the address is latched on
the next valid CLK edge while ADV# is asserted.
During synchronous array and non-array read modes, the first word is output from the
data buffer on the next valid CLK edge after the initial access latency delay (see Section
11.2.2, “Latency Count” on page 41). Subsequent data is output on valid CLK edges
following a minimum delay. However, for a synchronous non-array read, the same word
of data will be output on successive clock edges until the burst length requirements are
satisfied. Refer to the following waveforms for more detailed information:
• Figure 24, “Synchronous Single-Word Array or Non-array Read Timing” on page 60
• Figure 25, “Continuous Burst Read, Showing An Output Delay Timing” on page 61
• Figure 26, “Synchronous Burst-Mode Four-Word Read Timing” on page 61
Datasheet
26
August 2008
306666-12
P30
7.3
Read Device Identifier
The Read Device Identifier command instructs the device to output manufacturer code,
device identifier code, block-lock status, protection register data, or configuration
register data.
Table 13: Device Identifier Information
Item
Address(1)
Data
Manufacturer Code
0x00
0x01
0089h
ID
Device ID Code
Block Lock Configuration:
• Block Is Unlocked
Lock Bit:
DQ0 = 0b0
• Block Is Locked
BBA + 0x02
DQ0 = 0b1
• Block Is not Locked-Down
• Block Is Locked-Down
Read Configuration Register
Lock Register 0
DQ1 = 0b0
DQ1 = 0b1
0x05
0x80
RCR Contents
PR-LK0
64-bit Factory-Programmed Protection Register
64-bit User-Programmable Protection Register
Lock Register 1
0x81–0x84
0x85–0x88
0x89
Factory Protection Register Data
User Protection Register Data
PR-LK1
128-bit User-Programmable Protection Registers
Notes:
0x8A–0x109
Protection Register Data
1.
BBA = Block Base Address.
Table 14: Device ID codes
Device Identifier Codes
ID Code Type
Device Density
–T
–B
(Top Parameter)
(Bottom Parameter)
64-Mbit
128-Mbit
256-Mbit
8817
8818
8919
881A
881B
891C
Device Code
Note: The 512-Mbit devices do not have a Device ID associated with them. Each die within the stack can be identified by
either of the 256-Mbit Device ID codes depending on its parameter option.
7.4
Read CFI
The Read CFI command instructs the device to output Common Flash Interface (CFI)
data when read. See Section 6.0, “Command Set” on page 23 for details on issuing the
Read CFI command. Appendix A, “Common Flash Interface Tables” on page 69 shows
CFI information and address offsets within the CFI database.
August 2008
Order Number: 306666-12
Datasheet
27
P30
8.0
Program Operation
The device supports three programming methods: Word Programming (40h/10h),
Buffered Programming (E8h, D0h), and Buffered Enhanced Factory Programming (80h,
D0h). See
Section 5.0, “Bus Operations” on page 21 for details on the various programming
commands issued to the device. The following sections describe device programming in
detail.
Successful programming requires the addressed block to be unlocked. If the block is
locked down, WP# must be deasserted and the block must be unlocked before
attempting to program the block. Attempting to program a locked block causes a
program error (SR[4] and SR[1] set) and termination of the operation. See Section
10.0, “Security Modes” on page 36 for details on locking and unlocking blocks.
The Product Name is segmented into multiple 8-Mbit Programming Regions. See
Section 1.4, “Memory Maps” on page 6 for complete addressing. Execute in Place (XIP)
applications must partition the memory such that code and data are in separate
programming regions. XIP is executing code directly from flash memory. Each
Programming Region should contain only code or data but not both. The following
terms define the difference between code and data. System designs must use these
definitions when partitioning their code and data for the P30 device.
• Code: Execution code ran out of the flash device on a continuous basis in the
system.
• Data: Information periodically programmed into the flash device and read back
(e.g. execution code shadowed and executed in RAM, pictures, log files, etc.).
8.1
Word Programming
Word programming operations are initiated by writing the Word Program Setup
command to the device (see Section 5.0, “Bus Operations” on page 21). This is
followed by a second write to the device with the address and data to be programmed.
The device outputs Status Register data when read. See Figure 34, “Word Program
Flowchart” on page 79. VPP must be above VPPLK, and within the specified VPPL min/
max values.
During programming, the Write State Machine (WSM) executes a sequence of
internally-timed events that program the desired data bits at the addressed location,
and verifies that the bits are sufficiently programmed. Programming the flash memory
array changes “ones” to “zeros”. Memory array bits that are zeros can be changed to
ones only by erasing the block (see Section 9.0, “Erase Operations” on page 34).
The Status Register can be examined for programming progress and errors by reading
at any address. The device remains in the Read Status Register state until another
command is written to the device.
Status Register bit SR[7] indicates the programming status while the sequence
executes. Commands that can be issued to the device during programming are
Program Suspend, Read Status Register, Read Device Identifier, Read CFI, and Read
Array (this returns unknown data).
When programming has finished, Status Register bit SR[4] (when set) indicates a
programming failure. If SR[3] is set, the WSM could not perform the word
programming operation because VPP was outside of its acceptable limits. If SR[1] is set,
the word programming operation attempted to program a locked block, causing the
operation to abort.
Datasheet
28
August 2008
306666-12
P30
Before issuing a new command, the Status Register contents should be examined and
then cleared using the Clear Status Register command. Any valid command can follow,
when word programming has completed.
8.2
Factory Word Programming
Factory word programming is similar to word programming in that it uses the same
commands and programming algorithms. However, factory word programming
enhances the programming performance with VPP = VPPH. This can enable faster
programming times during OEM manufacturing processes. Factory word programming
is not intended for extended use. See Section 13.2, “Operating Conditions” on page 51
for limitations when VPP = VPPH
.
Note: When VPP = VPPL, the device draws programming current from the VCC supply. If VPP is driven
by a logic signal, VPPL must remain above VPPL MIN to program the device. When VPP = VPPH
,
the device draws programming current from the VPP supply. Figure 11, “Example VPP Supply
Connections” on page 33 shows examples of device power supply configurations.
8.3
Buffered Programming
The device features a 32-word buffer to enable optimum programming performance.
For Buffered Programming, data is first written to an on-chip write buffer. Then the
buffer data is programmed into the flash memory array in buffer-size increments. This
can improve system programming performance significantly over non-buffered
programming.
When the Buffered Programming Setup command is issued (see Section 6.0,
“Command Set” on page 23), Status Register information is updated and reflects the
availability of the buffer. SR[7] indicates buffer availability: if set, the buffer is
available; if cleared, the buffer is not available. To retry, issue the Buffered
Programming Setup command again, and re-check SR[7]. When SR[7] is set, the
buffer is ready for loading. (see Figure 36, “Buffer Program Flowchart” on page 81).
On the next write, a word count is written to the device at the buffer address. This tells
the device how many data words will be written to the buffer, up to the maximum size
of the buffer.
On the next write, a device start address is given along with the first data to be written
to the flash memory array. Subsequent writes provide additional device addresses and
data. All data addresses must lie within the start address plus the word count.
Optimum programming performance and lower power usage are obtained by aligning
the starting address at the beginning of a 32-word boundary (A[4:0] = 0x00). Crossing
a 32-word boundary during programming will double the total programming time.
After the last data is written to the buffer, the Buffered Programming Confirm command
must be issued to the original block address. The WSM begins to program buffer
contents to the flash memory array. If a command other than the Buffered
Programming Confirm command is written to the device, a command sequence error
occurs and Status Register bits SR[7,5,4] are set. If an error occurs while writing to the
array, the device stops programming, and Status Register bits SR[7,4] are set,
indicating a programming failure.
When Buffered Programming has completed, additional buffer writes can be initiated by
issuing another Buffered Programming Setup command and repeating the buffered
program sequence. Buffered programming may be performed with VPP = VPPL or VPPH
(see Section 13.2, “Operating Conditions” on page 51 for limitations when operating
the device with VPP = VPPH).
August 2008
Order Number: 306666-12
Datasheet
29
P30
If an attempt is made to program past an erase-block boundary using the Buffered
Program command, the device aborts the operation. This generates a command
sequence error, and Status Register bits SR[5,4] are set.
If Buffered programming is attempted while VPP is below VPPLK, Status Register bits
SR[4,3] are set. If any errors are detected that have set Status Register bits, the
Status Register should be cleared using the Clear Status Register command.
8.4
Buffered Enhanced Factory Programming
Buffered Enhanced Factory Programing (BEFP) speeds up Multi-Level Cell (MLC) flash
programming. The enhanced programming algorithm used in BEFP eliminates
traditional programming elements that drive up overhead in device programmer
systems.
BEFP consists of three phases: Setup, Program/Verify, and Exit (see Figure 37, “BEFP
Flowchart” on page 82). It uses a write buffer to spread MLC program performance
across 32 data words. Verification occurs in the same phase as programming to
accurately program the flash memory cell to the correct bit state.
A single two-cycle command sequence programs the entire block of data. This
enhancement eliminates three write cycles per buffer: two commands and the word
count for each set of 32 data words. Host programmer bus cycles fill the device’s write
buffer followed by a status check. SR[0] indicates when data from the buffer has been
programmed into sequential flash memory array locations.
Following the buffer-to-flash array programming sequence, the Write State Machine
(WSM) increments internal addressing to automatically select the next 32-word array
boundary. This aspect of BEFP saves host programming equipment the address-bus
setup overhead.
With adequate continuity testing, programming equipment can rely on the WSM’s
internal verification to ensure that the device has programmed properly. This eliminates
the external post-program verification and its associated overhead.
8.4.1
BEFP Requirements and Considerations
Table 15: BEFP Requirements
Parameter/Issue
Requirement
Notes
Case Temperature
TC = 25 °C ± 5 °C
VCC
Within operating range
Driven to VPPH
VPP
Setup and Confirm
Target block unlocked before issuing the BEFP Setup and Confirm commands
The first-word address (WA0) of the block to be programmed must be held constant
from the setup phase through all data streaming into the target block, until transition
to the exit phase is desired
Programming
Buffer Alignment
Note:
WA0 must align with the start of an array buffer boundary
1
1.
Word buffer boundaries in the array are determined by A[4:0] (0x00 through 0x1F). The alignment start point is A[4:0] =
0x00.
Datasheet
30
August 2008
306666-12
P30
Table 16: BEFP Considerations
Parameter/Issue
Requirement
Notes
Cycling
For optimum performance, cycling must be limited below 100 erase cycles per block.
BEFP programs one block at a time; all buffer data must fall within a single block
BEFP cannot be suspended
1
2
Programming blocks
Suspend
Programming the flash
memory array
Programming to the flash memory array can occur only when the buffer is full.
3
Note:
1.
2.
3.
Some degradation in performance may occur if this limit is exceeded, but the internal algorithm continues to work
properly.
If the internal address counter increments beyond the block's maximum address, addressing wraps around to the
beginning of the block.
If the number of words is less than 32, remaining locations must be filled with 0xFFFF.
8.4.2
BEFP Setup Phase
After receiving the BEFP Setup and Confirm command sequence, Status Register bit
SR[7] (Ready) is cleared, indicating that the WSM is busy with BEFP algorithm startup.
A delay before checking SR[7] is required to allow the WSM enough time to perform all
of its setups and checks (Block-Lock status, VPP level, etc.). If an error is detected,
SR[4] is set and BEFP operation terminates. If the block was found to be locked, SR[1]
is also set. SR[3] is set if the error occurred due to an incorrect VPP level.
Note: Reading from the device after the BEFP Setup and Confirm command sequence outputs
Status Register data. Do not issue the Read Status Register command; it will be interpreted
as data to be loaded into the buffer.
8.4.3
BEFP Program/Verify Phase
After the BEFP Setup Phase has completed, the host programming system must check
SR[7,0] to determine the availability of the write buffer for data streaming. SR[7]
cleared indicates the device is busy and the BEFP program/verify phase is activated.
SR[0] indicates the write buffer is available.
Two basic sequences repeat in this phase: loading of the write buffer, followed by buffer
data programming to the array. For BEFP, the count value for buffer loading is always
the maximum buffer size of 32 words. During the buffer-loading sequence, data is
stored to sequential buffer locations starting at address 0x00. Programming of the
buffer contents to the flash memory array starts as soon as the buffer is full. If the
number of words is less than 32, the remaining buffer locations must be filled with 0xFFFF.
Caution:
The buffer must be completely filled for programming to occur. Supplying an
address outside of the current block's range during a buffer-fill sequence
causes the algorithm to exit immediately. Any data previously loaded into the
buffer during the fill cycle is not programmed into the array.
The starting address for data entry must be buffer size aligned, if not the BEFP
algorithm will be aborted and the program fails and (SR[4]) flag will be set.
Data words from the write buffer are directed to sequential memory locations in the
flash memory array; programming continues from where the previous buffer sequence
ended. The host programming system must poll SR[0] to determine when the buffer
program sequence completes. SR[0] cleared indicates that all buffer data has been
transferred to the flash array; SR[0] set indicates that the buffer is not available yet for
the next fill cycle. The host system may check full status for errors at any time, but it is
August 2008
Order Number: 306666-12
Datasheet
31
P30
only necessary on a block basis after BEFP exit. After the buffer fill cycle, no write
cycles should be issued to the device until SR[0] = 0 and the device is ready for the
next buffer fill.
Note: Any spurious writes are ignored after a buffer fill operation and when internal program is
proceeding.
The host programming system continues the BEFP algorithm by providing the next
group of data words to be written to the buffer. Alternatively, it can terminate this
phase by changing the block address to one outside of the current block’s range.
The Program/Verify phase concludes when the programmer writes to a different block
address; data supplied must be 0xFFFF. Upon Program/Verify phase completion, the
device enters the BEFP Exit phase.
8.4.4
8.5
BEFP Exit Phase
When SR[7] is set, the device has returned to normal operating conditions. A full status
check should be performed at this time to ensure the entire block programmed
successfully. When exiting the BEFP algorithm with a block address change, the read
mode will not change. After BEFP exit, any valid command can be issued to the device.
Program Suspend
Issuing the Program Suspend command while programming suspends the
programming operation. This allows data to be accessed from the device other than the
one being programmed. The Program Suspend command can be issued to any device
address. A program operation can be suspended to perform reads only. Additionally, a
program operation that is running during an erase suspend can be suspended to
perform a read operation (see Figure 35, “Program Suspend/Resume Flowchart” on
page 80).
When a programming operation is executing, issuing the Program Suspend command
requests the WSM to suspend the programming algorithm at predetermined points. The
device continues to output Status Register data after the Program Suspend command is
issued. Programming is suspended when Status Register bits SR[7,2] are set. Suspend
latency is specified in Section 16.0, “Program and Erase Characteristics” on page 66.
To read data from the device, the Read Array command must be issued. Read Array,
Read Status Register, Read Device Identifier, Read CFI, and Program Resume are valid
commands during a program suspend.
During a program suspend, deasserting CE# places the device in standby, reducing
active current. VPP must remain at its programming level, and WP# must remain
unchanged while in program suspend. If RST# is asserted, the device is reset.
8.6
Program Resume
The Resume command instructs the device to continue programming, and
automatically clears Status Register bits SR[7,2]. This command can be written to any
address. If error bits are set, the Status Register should be cleared before issuing the
next instruction. RST# must remain deasserted (see Figure 35, “Program Suspend/
Resume Flowchart” on page 80).
Datasheet
32
August 2008
306666-12
P30
8.7
Program Protection
When VPP = VIL, absolute hardware write protection is provided for all device blocks. If
V
PP is at or below VPPLK, programming operations halt and SR[3] is set indicating a VPP-
level error. Block lock registers are not affected by the voltage level on VPP; they may
still be programmed and read, even if VPP is less than VPPLK
.
Figure 11: Example VPP Supply Connections
VCC
VCC
VPP
VCC
VPP
VCC
VPP
PROT #
≤ 10K Ω
• Low-voltage Programming only
• Logic Control of Device Protection
• Factory Programming with VPP = VPPH
• Complete write/Erase Protection when VPP ≤ VPPLK
VCC
VCC
VCC
VCC
VPP
VPP=VPPH
VPP
• Low Voltage Programming Only
• Full Device Protection Unavailable
• Low Voltage and Factory Programming
August 2008
Order Number: 306666-12
Datasheet
33
P30
9.0
Erase Operations
Flash erasing is performed on a block basis. An entire block is erased each time an
erase command sequence is issued, and only one block is erased at a time. When a
block is erased, all bits within that block read as logical ones. The following sections
describe block erase operations in detail.
9.1
Block Erase
Block erase operations are initiated by writing the Block Erase Setup command to the address of the block to
be erased (see Section 6.0, “Command Set” on page 23). Next, the Block Erase Confirm command
is written to the address of the block to be erased. If the device is placed in standby (CE#
deasserted) during an erase operation, the device completes the erase operation before
entering standby.VPP must be above VPPLK and the block must be unlocked (see Figure 38, “Block
Erase Flowchart” on page 83).
During a block erase, the Write State Machine (WSM) executes a sequence of
internally-timed events that conditions, erases, and verifies all bits within the block.
Erasing the flash memory array changes “zeros” to “ones”. Memory array bits that are
ones can be changed to zeros only by programming the block (see Section 8.0,
“Program Operation” on page 28).
The Status Register can be examined for block erase progress and errors by reading
any address. The device remains in the Read Status Register state until another
command is written. SR[0] indicates whether the addressed block is erasing. Status
Register bit SR[7] is set upon erase completion.
Status Register bit SR[7] indicates block erase status while the sequence executes.
When the erase operation has finished, Status Register bit SR[5] indicates an erase
failure if set. SR[3] set would indicate that the WSM could not perform the erase
operation because VPP was outside of its acceptable limits. SR[1] set indicates that the
erase operation attempted to erase a locked block, causing the operation to abort.
Before issuing a new command, the Status Register contents should be examined and
then cleared using the Clear Status Register command. Any valid command can follow
once the block erase operation has completed.
9.2
Erase Suspend
Issuing the Erase Suspend command while erasing suspends the block erase operation.
This allows data to be accessed from memory locations other than the one being
erased. The Erase Suspend command can be issued to any device address. A block
erase operation can be suspended to perform a word or buffer program operation, or a
read operation within any block except the block that is erase suspended (see
Figure 35, “Program Suspend/Resume Flowchart” on page 80).
When a block erase operation is executing, issuing the Erase Suspend command
requests the WSM to suspend the erase algorithm at predetermined points. The device
continues to output Status Register data after the Erase Suspend command is issued.
Block erase is suspended when Status Register bits SR[7,6] are set. Suspend latency is
specified in Section 16.0, “Program and Erase Characteristics” on page 66.
To read data from the device (other than an erase-suspended block), the Read Array
command must be issued. During Erase Suspend, a Program command can be issued
to any block other than the erase-suspended block. Block erase cannot resume until
program operations initiated during erase suspend complete. Read Array, Read Status
Register, Read Device Identifier, Read CFI, and Erase Resume are valid commands
Datasheet
34
August 2008
306666-12
P30
during Erase Suspend. Additionally, Clear Status Register, Program, Program Suspend,
Block Lock, Block Unlock, and Block Lock-Down are valid commands during Erase
Suspend.
During an erase suspend, deasserting CE# places the device in standby, reducing
active current. VPP must remain at a valid level, and WP# must remain unchanged
while in erase suspend. If RST# is asserted, the device is reset.
9.3
9.4
Erase Resume
The Erase Resume command instructs the device to continue erasing, and
automatically clears status register bits SR[7,6]. This command can be written to any
address. If status register error bits are set, the Status Register should be cleared
before issuing the next instruction. RST# must remain deasserted (see Figure 35,
“Program Suspend/Resume Flowchart” on page 80).
Erase Protection
When VPP = VIL, absolute hardware erase protection is provided for all device blocks. If
VPP is below VPPLK, erase operations halt and SR[3] is set indicating a VPP-level error.
August 2008
Order Number: 306666-12
Datasheet
35
P30
10.0
Security Modes
The device features security modes used to protect the information stored in the flash
memory array. The following sections describe each security mode in detail.
10.1
Block Locking
Individual instant block locking is used to protect user code and/or data within the flash
memory array. All blocks power up in a locked state to protect array data from being
altered during power transitions. Any block can be locked or unlocked with no latency.
Locked blocks cannot be programmed or erased; they can only be read.
Software-controlled security is implemented using the Block Lock and Block Unlock
commands. Hardware-controlled security can be implemented using the Block Lock-
Down command along with asserting WP#. Also, VPP data security can be used to
inhibit program and erase operations (see Section 8.7, “Program Protection” on
page 33 and Section 9.4, “Erase Protection” on page 35).
The P30 device also offers four pre-defined areas in the main array that can be
configured as One-Time Programmable (OTP) for the highest level of security. These
include the four 32 KB parameter blocks together as one and the three adjacent 128 KB
main blocks. This is available for top or bottom parameter devices.
10.1.1
Lock Block
To lock a block, issue the Lock Block Setup command. The next command must be the Lock Block command
issued to the desired block’s address (see Section 6.0, “Command Set” on page 23and Figure 40,
“Block Lock Operations Flowchart” on page 85). If the Set Read Configuration Register
command is issued after the Block Lock Setup command, the device configures the RCR
instead.
Block lock and unlock operations are not affected by the voltage level on VPP. The block
lock bits may be modified and/or read even if VPP is at or below VPPLK
.
10.1.2
10.1.3
Unlock Block
The Unlock Block command is used to unlock blocks (see Section 6.0, “Command Set”
on page 23). Unlocked blocks can be read, programmed, and erased. Unlocked blocks
return to a locked state when the device is reset or powered down. If a block is in a
lock-down state, WP# must be deasserted before it can be unlocked (see Figure 12,
“Block Locking State Diagram” on page 37).
Lock-Down Block
A locked or unlocked block can be locked-down by writing the Lock-Down Block
command sequence (see Section 6.0, “Command Set” on page 23). Blocks in a lock-
down state cannot be programmed or erased; they can only be read. However, unlike
locked blocks, their locked state cannot be changed by software commands alone. A
locked-down block can only be unlocked by issuing the Unlock Block command with
WP# deasserted. To return an unlocked block to locked-down state, a Lock-Down
command must be issued prior to changing WP# to VIL. Locked-down blocks revert to
the locked state upon reset or power up the device (see Figure 12, “Block Locking State
Diagram” on page 37).
Datasheet
36
August 2008
306666-12
P30
10.1.4
Block Lock Status
The Read Device Identifier command is used to determine a block’s lock status (see
Section 12.0, “Power and Reset Specifications” on page 49). Data bits DQ[1:0] display
the addressed block’s lock status; DQ0 is the addressed block’s lock bit, while DQ1 is
the addressed block’s lock-down bit.
Figure 12: Block Locking State Diagram
Locked-
Down4,5
[011]
Hardware
Locked5
[011]
Locked
Power-Up/Reset
[X01]
WP# Hardware Control
Software
Locked
Unlocked
Unlocked
[X00]
[111]
[110]
Software Block Lock (0x60/0x01) or Software Block Unlock (0x60/0xD0)
Software Block Lock-Down (0x60/0x2F)
WP# hardware control
Notes:
1. [a,b,c] represents [WP#, DQ1, DQ0]. X = Don’t Care.
2. DQ1 indicates Block Lock-Down status. DQ1 = ‘0’, Lock-Down has not been issued
to this block. DQ1 = ‘1’, Lock-Down has been issued to this block.
3. DQ0 indicates block lock status. DQ0 = ‘0’, block is unlocked. DQ0 = ‘1’, block is
locked.
4. Locked-down = Hardware + Software locked.
5. [011] states should be tracked by system software to determine difference between
Hardware Locked and Locked-Down states.
10.1.5
Block Locking During Suspend
Block lock and unlock changes can be performed during an erase suspend. To change
block locking during an erase operation, first issue the Erase Suspend command.
Monitor the Status Register until SR[7] and SR[6] are set, indicating the device is
suspended and ready to accept another command.
Next, write the desired lock command sequence to a block, which changes the lock
state of that block. After completing block lock or unlock operations, resume the erase
operation using the Erase Resume command.
Note: A Lock Block Setup command followed by any command other than Lock Block, Unlock Block,
or Lock-Down Block produces a command sequence error and set Status Register bits SR[4]
and SR[5]. If a command sequence error occurs during an erase suspend, SR[4] and SR[5]
remains set, even after the erase operation is resumed. Unless the Status Register is cleared
using the Clear Status Register command before resuming the erase operation, possible erase
errors may be masked by the command sequence error.
August 2008
Order Number: 306666-12
Datasheet
37
P30
If a block is locked or locked-down during an erase suspend of the same block, the lock
status bits change immediately. However, the erase operation completes when it is
resumed. Block lock operations cannot occur during a program suspend. See Appendix
A, “Write State Machine” on page 86, which shows valid commands during an erase
suspend.
10.2
Selectable One-Time Programmable Blocks
Any of four pre-defined areas from the main array (the four 32-KB parameter blocks
together as one and three adjacent 128 KB main blocks) can be configured as OTP so
further program and erase operations are not allowed. This option is available for top or
bottom parameter devices.
Table 17: Selectable OTP Block Mapping
Density
Top Parameter Configuration
Bottom Parameter Configuration
blocks 258:255 (parameters)
block 254 (main)
blocks 3:0 (parameters)
block 4 (main)
256-Mbit
block 253 (main)
block 5 (main)
block 252 (main)
block 6 (main)
blocks 130:127 (parameters)
block 126 (main)
blocks 3:0 (parameters)
block 4 (main)
128-Mbit
block 125 (main)
block 5 (main)
block 124 (main)
block 6 (main)
blocks 66:63 (parameters)
block 62 (main)
blocks 3:0 (parameters)
block 4 (main)
64-Mbit
block 61 (main)
block 5 (main)
block 60 (main)
block 6 (main)
Notes:
1.
The 512-Mbit devices will have multiple die and selectable OTP areas depending on the placement of the parameter
blocks.
2.
When programming the OTP bits for a Top Parameter Device, the following upper address bits must also be driven
properly: A[Max:17] driven high (VIH) for TSOP and Easy BGA packages, and A[Max:16] driven high (VIH) for QUAD+
SCSP.
Note: Please see your local Numonyx representative for details about the Selectable OTP
implementation.
Datasheet
38
August 2008
306666-12
P30
11.0
Registers
When non-array reads are performed in asynchronous page mode only the first data is
valid and all subsequent data are undefined. When a non-array read operation occurs
as synchronous burst mode, the same word of data requested will be output on
successive clock edges until the burst length requirements are satisfied.
11.1
Read Status Register
To read the Status Register, issue the Read Status Register command at any address.
Status Register information is available to which the Read Status Register, Word
Program, or Block Erase command was issued. Status Register data is automatically
made available following a Word Program, Block Erase, or Block Lock command
sequence. Reads from the device after any of these command sequences outputs the
device’s status until another valid command is written (e.g. Read Array command).
The Status Register is read using single asynchronous-mode or synchronous burst
mode reads. Status Register data is output on DQ[7:0], while 0x00 is output on
DQ[15:8]. In asynchronous mode the falling edge of OE#, or CE# (whichever occurs
first) updates and latches the Status Register contents. However, reading the Status
Register in synchronous burst mode, CE# or ADV# must be toggled to update status
data.
The Device Write Status bit (SR[7]) provides overall status of the device. Status
register bits SR[6:1] present status and error information about the program, erase,
suspend, VPP, and block-locked operations.
Table 18: Status Register Description (Sheet 1 of 2)
Status Register (SR)
Default Value = 0x80
Program
Suspend
Status
Device Write EraseSuspend
Program
Status
Block-Locked
BEFP
Status
Erase Status
VPP Status
Status
Status
Status
DWS
7
ESS
6
ES
5
PS
4
VPPS
3
PSS
2
BLS
1
BWS
0
Bit
Name
Description
0 = Device is busy; program or erase cycle in progress; SR[0] valid.
1 = Device is ready; SR[6:1] are valid.
7
6
5
4
3
Device Write Status (DWS)
Erase Suspend Status (ESS)
Erase Status (ES)
0 = Erase suspend not in effect.
1 = Erase suspend in effect.
0 = Erase successful.
1 = Erase fail or program sequence error when set with SR[4,7].
0 = Program successful.
1 = Program fail or program sequence error when set with SR[5,7]
Program Status (PS)
VPP Status (VPPS)
0 = VPP within acceptable limits during program or erase operation.
1 = VPP < VPPLK during program or erase operation.
August 2008
Order Number: 306666-12
Datasheet
39
P30
Table 18: Status Register Description (Sheet 2 of 2)
Status Register (SR)
Default Value = 0x80
0 = Program suspend not in effect.
1 = Program suspend in effect.
2
1
Program Suspend Status (PSS)
Block-Locked Status (BLS)
0 = Block not locked during program or erase.
1 = Block locked during program or erase; operation aborted.
After Buffered Enhanced Factory Programming (BEFP) data is loaded into the
buffer:
0 = BEFP complete.
0
BEFP Status (BWS)
1 = BEFP in-progress.
Note: Always clear the Status Register prior to resuming erase operations. It avoids Status Register
ambiguity when issuing commands during Erase Suspend. If a command sequence error
occurs during an erase-suspend state, the Status Register contains the command sequence
error status (SR[7,5,4] set). When the erase operation resumes and finishes, possible errors
during the erase operation cannot be detected via the Status Register because it contains the
previous error status.
11.1.1
Clear Status Register
The Clear Status Register command clears the status register. It functions independent
of VPP. The Write State Machine (WSM) sets and clears SR[7,6,2], but it sets bits
SR[5:3,1] without clearing them. The Status Register should be cleared before starting
a command sequence to avoid any ambiguity. A device reset also clears the Status
Register.
11.2
Read Configuration Register
The Read Configuration Register (RCR) is used to select the read mode (synchronous or
asynchronous), and it defines the synchronous burst characteristics of the device. To
modify RCR settings, use the Configure Read Configuration Register command (see
Section 6.0, “Command Set” on page 23).
RCR contents can be examined using the Read Device Identifier command, and then
reading from offset 0x05 (see Section 12.0, “Power and Reset Specifications” on
page 49).
The RCR is shown in Table 19. The following sections describe each RCR bit.
Table 19: Read Configuration Register Description (Sheet 1 of 2)
Read Configuration Register (RCR)
Data
Hold
WAIT
Delay
Burst
Wrap
Read
Mode
WAIT
Polarity
Burst
Seq
CLK
Edge
RES
Latency Count
LC[2:0]
RES
RES
Burst Length
RM
15
Bit
R
WP
10
DH
9
WD
8
BS
7
CE
6
R
5
R
4
BW
3
BL[2:0]
1
14
13
12
11
2
0
Name
Description
0 = Synchronous burst-mode read
1 = Asynchronous page-mode read (default)
15
Read Mode (RM)
Reserved (R)
14
Reserved bits should be cleared (0)
Datasheet
40
August 2008
306666-12
P30
Table 19: Read Configuration Register Description (Sheet 2 of 2)
010 =Code 2
011 =Code 3
100 =Code 4
101 =Code 5
Latency Count (LC[2:0])
13:11
110 =Code 6
111 =Code 7 (default)
(Other bit settings are reserved)
0 =WAIT signal is active low
1 =WAIT signal is active high (default)
Wait Polarity (WP)
Data Hold (DH)
10
0 =Data held for a 1-clock data cycle
1 =Data held for a 2-clock data cycle (default)
9
8
7
0 =WAIT deasserted with valid data
1 =WAIT deasserted one data cycle before valid data (default)
Wait Delay (WD)
Burst Sequence (BS)
0 =Reserved
1 =Linear (default)
Clock Edge (CE)
0 = Falling edge
1 = Rising edge (default)
6
5:4
3
Reserved (R)
Reserved bits should be cleared (0)
Burst Wrap (BW)
0 =Wrap; Burst accesses wrap within burst length set by BL[2:0]
1 =No Wrap; Burst accesses do not wrap within burst length (default)
001 =4-word burst
010 =8-word burst
011 =16-word burst
111 =Continuous-word burst (default)
2:0
Burst Length (BL[2:0])
(Other bit settings are reserved)
Note: Latency Code 2, Data Hold for a 2-clock data cycle (DH = 1) WAIT must be deasserted with valid data (WD = 0).
Latency Code 2, Data Hold for a 2-cock data cycle (DH=1) WAIT deasserted one data cycle before valid data (WD = 1)
combination is not supported. Table 19, “Read Configuration Register Description” on page 40 is
shown using the QUAD+ package. For EASY BGA and TSOP packages, the table reference should be adjusted using
address bits A[16:1].
11.2.1
Read Mode
The Read Mode (RM) bit selects synchronous burst-mode or asynchronous page-mode
operation for the device. When the RM bit is set, asynchronous page mode is selected
(default). When RM is cleared, synchronous burst mode is selected.
11.2.2
Latency Count
The Latency Count (LC) bits tell the device how many clock cycles must elapse from the
rising edge of ADV# (or from the first valid clock edge after ADV# is asserted) until the
first valid data word is to be driven onto DQ[15:0]. The input clock frequency is used to
determine this value and Figure 13 shows the data output latency for the different
settings of LC. The maximum Latency Count for P30 would be Code 4 based on the Max
Clock frequency specification of 52 mhz, and there will be zero WAIT States when
bursting within the word line. Please also refer to “End of Word Line (EOWL)
Considerations” on page 46 for more information on EOWL.
Refer to Table 20, “Latency Count (LC) and Frequency Support” on page 42 for Latency
Code Settings.
August 2008
Order Number: 306666-12
Datasheet
41
P30
Figure 13: First-Access Latency Count
CLK [C]
Valid
Address
Address [A]
ADV# [V]
Code 0 (Reserved)
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
DQ15-0 [D/Q]
Code 1
(Reserved
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Code 2
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Code 3
Code 4
Code 5
Code 6
Code 7
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Valid
Output
Table 20: Latency Count (LC) and Frequency Support
Latency Count Settings
Frequency Support (MHz)
2
3
4
£ 27
£ 40
£ 52
Note: Synchronous burst read operation is currently not supported for the TSOP package.
Datasheet
42
August 2008
306666-12
P30
Figure 14: Example Latency Count Setting using Code 3
tData
0
1
2
3
4
CLK
CE#
ADV#
Address
A[MAX:0]
Code 3
High-Z
Data
D[15:0]
R103
11.2.3
WAIT Polarity
The WAIT Polarity bit (WP), RCR[10] determines the asserted level (VOH or VOL) of
WAIT. When WP is set, WAIT is asserted high (default). When WP is cleared, WAIT is
asserted low. WAIT changes state on valid clock edges during active bus cycles (CE#
asserted, OE# asserted, RST# deasserted).
11.2.3.1
WAIT Signal Function
The WAIT signal indicates data valid when the device is operating in synchronous mode
(RCR[15]=0). The WAIT signal is only “deasserted” when data is valid on the bus.
When the device is operating in synchronous non-array read mode, such as read
status, read ID, or read CFI. The WAIT signal is also “deasserted” when data is valid on
the bus.
WAIT behavior during synchronous non-array reads at the end of word line works
correctly only on the first data access.
When the device is operating in asynchronous page mode, asynchronous single word
read mode, and all write operations, WAIT is set to a deasserted state as determined
by RCR[10]. See Figure 22, “Asynchronous Single-Word Read (ADV# Latch)” on
page 59, and Figure 23, “Asynchronous Page-Mode Read Timing” on page 60.
Table 21: WAIT Functionality Table (Sheet 1 of 2)
Condition
WAIT
Notes
CE# = ‘1’, OE# = ‘X’ or CE# = ‘0’, OE# = ‘1’
CE# =’0’, OE# = ‘0’
High-Z
Active
Active
Active
1
1
1
1
Synchronous Array Reads
Synchronous Non-Array Reads
August 2008
Order Number: 306666-12
Datasheet
43
P30
Table 21: WAIT Functionality Table (Sheet 2 of 2)
Condition
WAIT
Notes
All Asynchronous Reads
All Writes
Deasserted
High-Z
1
1,2
Notes:
1.
2.
Active: WAIT is asserted until data becomes valid, then deasserts
When OE# = VIH during writes, WAIT = High-Z
11.2.4
Data Hold
For burst read operations, the Data Hold (DH) bit determines whether the data output
remains valid on DQ[15:0] for one or two clock cycles. This period of time is called the
“data cycle”. When DH is set, output data is held for two clocks (default). When DH is
cleared, output data is held for one clock (see Figure 15). The processor’s data setup
time and the flash memory’s clock-to-data output delay should be considered when
determining whether to hold output data for one or two clocks. A method for
determining the Data Hold configuration is shown below:
To set the device at one clock data hold for subsequent reads, the following condition
must be satisfied:
tCHQV (ns) + tDATA (ns) ≤ One CLK Period (ns)
tDATA = Data set up to Clock (defined by CPU)
For example, with a clock frequency of 40 MHz, the clock period is 25 ns. Assuming
tCHQV = 20 ns and tDATA = 4 ns. Applying these values to the formula above:
20 ns + 4 ns ≤ 25 ns
The equation is satisfied and data will be available at every clock period with data hold
setting at one clock. If tCHQV (ns) + tDATA (ns) >One CLK Period (ns), data hold setting of
2 clock periods must be used.
Figure 15: Data Hold Timing
CLK [C]
1 CLK
Data Hold
Valid
Output
Valid
Output
Valid
Output
D[15:0] [Q]
2 CLK
Valid
Output
Valid
Output
D[15:0] [Q]
Data Hold
11.2.5
WAIT Delay
The WAIT Delay (WD) bit controls the WAIT assertion-delay behavior during
synchronous burst reads. WAIT can be asserted either during or one data cycle before
valid data is output on DQ[15:0]. When WD is set, WAIT is deasserted one data cycle
before valid data (default). When WD is cleared, WAIT is deasserted during valid data.
Datasheet
44
August 2008
306666-12
P30
11.2.6
Burst Sequence
The Burst Sequence (BS) bit selects linear-burst sequence (default). Only linear-burst
sequence is supported. Table 22 shows the synchronous burst sequence for all burst
lengths, as well as the effect of the Burst Wrap (BW) setting.
Table 22: Burst Sequence Word Ordering
Burst Addressing Sequence (DEC)
Start
Addr.
(DEC)
Burst
Wrap
(RCR[3])
4-Word Burst
(BL[2:0] =
0b001)
8-Word Burst
(BL[2:0] = 0b010)
16-Word Burst
(BL[2:0] = 0b011)
Continuous Burst
(BL[2:0] = 0b111)
0
1
2
3
4
5
0
0
0
0
0
0
0-1-2-3
1-2-3-0
2-3-0-1
3-0-1-2
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-0
2-3-4-5-6-7-0-1
3-4-5-6-7-0-1-2
4-5-6-7-0-1-2-3
5-6-7-0-1-2-3-4
0-1-2-3-4…14-15
1-2-3-4-5…15-0
0-1-2-3-4-5-6-…
1-2-3-4-5-6-7-…
2-3-4-5-6-7-8-…
3-4-5-6-7-8-9-…
4-5-6-7-8-9-10…
5-6-7-8-9-10-11…
2-3-4-5-6…15-0-1
3-4-5-6-7…15-0-1-2
4-5-6-7-8…15-0-1-2-3
5-6-7-8-9…15-0-1-2-3-4
6-7-8-9-10…15-0-1-2-3-4-
5
6
7
0
0
6-7-0-1-2-3-4-5
7-0-1-2-3-4-5-6
6-7-8-9-10-11-12-…
7-8-9-10-11-12-13…
7-8-9-10…15-0-1-2-3-4-5-
6
14
15
0
0
14-15-0-1-2…12-13
15-0-1-2-3…13-14
14-15-16-17-18-19-20-…
15-16-17-18-19-20-21-…
0
1
2
3
4
5
6
1
1
1
1
1
1
1
0-1-2-3
1-2-3-4
2-3-4-5
3-4-5-6
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-8
0-1-2-3-4…14-15
1-2-3-4-5…15-16
2-3-4-5-6…16-17
3-4-5-6-7…17-18
4-5-6-7-8…18-19
5-6-7-8-9…19-20
6-7-8-9-10…20-21
0-1-2-3-4-5-6-…
1-2-3-4-5-6-7-…
2-3-4-5-6-7-8-…
3-4-5-6-7-8-9-…
4-5-6-7-8-9-10…
5-6-7-8-9-10-11…
6-7-8-9-10-11-12-…
2-3-4-5-6-7-8-9
3-4-5-6-7-8-9-10
4-5-6-7-8-9-10-11
5-6-7-8-9-10-11-12
6-7-8-9-10-11-12-13
7-8-9-10-11-12-13-
14
7
1
7-8-9-10-11…21-22
7-8-9-10-11-12-13…
14
15
1
1
14-15-16-17-18…28-29
15-16-17-18-19…29-30
14-15-16-17-18-19-20-…
15-16-17-18-19-20-21-…
11.2.7
Clock Edge
The Clock Edge (CE) bit selects either a rising (default) or falling clock edge for CLK.
This clock edge is used at the start of a burst cycle, to output synchronous data, and to
assert/deassert WAIT.
August 2008
Order Number: 306666-12
Datasheet
45
P30
11.2.8
Burst Wrap
The Burst Wrap (BW) bit determines whether 4-word, 8-word, or 16-word burst length
accesses wrap within the selected word-length boundaries or cross word-length
boundaries. When BW is set, burst wrapping does not occur (default). When BW is
cleared, burst wrapping occurs.
When performing synchronous burst reads with BW set (no wrap), an output delay may
occur when the burst sequence crosses its first device-row (16-word) boundary. If the
burst sequence’s start address is 4-word aligned, then no delay occurs. If the start
address is at the end of a 4-word boundary, the worst case output delay is one clock
cycle less than the first access Latency Count. This delay can take place only once, and
doesn’t occur if the burst sequence does not cross a device-row boundary. WAIT
informs the system of this delay when it occurs.
11.2.9
Burst Length
The Burst Length bit (BL[2:0]) selects the linear burst length for all synchronous burst
reads of the flash memory array. The burst lengths are 4-word, 8-word, 16-word, and
continuous word.
Continuous-burst accesses are linear only, and do not wrap within any word length
boundaries (see Table 22, “Burst Sequence Word Ordering” on page 45). When a burst
cycle begins, the device outputs synchronous burst data until it reaches the end of the
“burstable” address space.
11.2.10
End of Word Line (EOWL) Considerations
When performing synchronous burst reads with BW set (no wrap) and DH reset (1 clock
cycle), an output “delay” requiring additions clock Wait States may occur when the
burst sequence crosses its first device-row (16-word) boundary. The delay would take
place only once, and will not occur if the burst sequence does not cross a device-row
boundary. The WAIT signal informs the system of this delay when it occurs. If the burst
sequence’s start address is 4-word aligned (i.e. 0x00h, 0x04h, 0x08h, 0x0Ch) then no
delay occurs. If the start address is at the end of a 4-word boundary (i.e. 0x03h,
0x07h, 0x0Bh, 0x0Fh), the worst case delay (number of Wait States required) will be
one clock cycle less than the first access Latency Count (LC-1) when crossing the first
device-row boundary (i.e. 0x0Fh to 0x10h). Other address misalignments may require
wait states depending upon the LC setting and the starting address alignment. For
example, an LC setting of 3 with a starting address of 0xFD requires 0 wait states, but
the same LC setting of 3 with a starting address of 0xFE would require 1 wait state
when crossing the first device row boundary.
11.3
One-Time-Programmable (OTP) Registers
The device contains 17 one-time-programmable (OTP) registers that can be used to
implement system security measures and/or device identification. Each OTP register
can be individually locked.
The first 128-bit OTP Register is comprised of two 64-bit (8-word) segments. The lower
64-bit segment is pre-programmed at the Numonyx factory with a unique 64-bit
number. The other 64-bit segment, as well as the other sixteen 128-bit OTP Registers,
are blank. Users can program these registers as needed. When programmed, users can
then lock the OTP Register(s) to prevent additional bit programming (see Figure 16,
“OTP register map” on page 47).
The OTP Registers contain one-time programmable (OTP) bits; when programmed, PR
bits cannot be erased. Each OTP Register can be accessed multiple times to program
individual bits, as long as the register remains unlocked.
Datasheet
46
August 2008
306666-12
P30
Each OTP Register has an associated Lock Register bit. When a Lock Register bit is
programmed, the associated OTP Register can only be read; it can no longer be
programmed. Additionally, because the Lock Register bits themselves are OTP, when
programmed, Lock Register bits cannot be erased. Therefore, when a OTP Register is
locked, it cannot be unlocked.
.
Figure 16: OTP register map
0x109
128-bit Protection Register 16
(User-Programmable)
0x102
0x91
128-bit Protection Register 1
(User-Programmable)
0x8A
0x89
Lock Register 1
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
0x88
64-bit Segment
(User-Programmable)
0x85
0x84
128-Bit Protection Register 0
64-bit Segment
(Factory-Programmed)
0x81
0x80
Lock Register 0
15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
11.3.1
Reading the OTP registers
The OTP registers can be read from any address. To read the OTP Register, first issue
the Read Device Identifier command at any address to place the device in the Read
Device Identifier state (see Section 6.0, “Command Set” on page 23). Next, perform a
read operation using the address offset corresponding to the register to be read.
Table 13, “Device Identifier Information” on page 27 shows the address offsets of the
OTP Registers and Lock Registers. PR data is read 16 bits at a time.
August 2008
Order Number: 306666-12
Datasheet
47
P30
11.3.2
Programming the OTP Registers
To program any of the OTP Registers, first issue the Program OTP Register command at
the parameter’s base address plus the offset to the desired OTP Register (see Section
6.0, “Command Set” on page 23). Next, write the desired OTP Register data to the
same OTP Register address (see Figure 16, “OTP register map” on page 47).
The device programs the 64-bit and 128-bit user-programmable OTP Register data 16
bits at a time (see Figure 41, “Protection Register Programming Flowchart” on
page 86). Issuing the Program OTP Register command outside of the OTP Register’s
address space causes a program error (SR[4] set). Attempting to program a locked
OTP Register causes a program error (SR[4] set) and a lock error (SR[1] set).
Note:
When programming the OTP bits in the OTP registers for a Top Parameter Device,
the following upper address bits must also be driven properly: A[Max:17] driven high
(VIH) for TSOP and Easy BGA packages, and A[Max:16] driven high (VIH) for QUAD+
SCSP.
11.3.3
Locking the OTP Registers
Each OTP Register can be locked by programming its respective lock bit in the Lock
Register. To lock a OTP Register, program the corresponding bit in the Lock Register by
issuing the Program Lock Register command, followed by the desired Lock Register
data (see Section 6.0, “Command Set” on page 23). The physical addresses of the Lock
Registers are 0x80 for register 0 and 0x89 for register 1. These addresses are used
when programming the lock registers (see Table 13, “Device Identifier Information” on
page 27).
Bit 0 of Lock Register 0 is already programmed during the manufacturing process at the
“factory”, locking the lower, pre-programmed 64-bit region of the first 128-bit OTP
Register containing the unique identification number of the device. Bit 1 of Lock
Register 0 can be programmed by the user to lock the user-programmable, 64-bit
region of the first 128-bit OTP Register. When programming Bit 1 of Lock Register 0, all
other bits need to be left as ‘1’ such that the data programmed is 0xFFFD.
Lock Register 1 controls the locking of the upper sixteen 128-bit OTP Registers. Each of
the 16 bits of Lock Register 1 correspond to each of the upper sixteen 128-bit OTP
Registers. Programming a bit in Lock Register 1 locks the corresponding 128-bit OTP
Register.
Caution:
After being locked, the OTP Registers cannot be unlocked.
Datasheet
48
August 2008
306666-12
P30
12.0
Power and Reset Specifications
12.1
Power-Up and Power-Down
Power supply sequencing is not required if VPP is connected to VCC or VCCQ. Otherwise
VCC and VCCQ should attain their minimum operating voltage before applying VPP.
Power supply transitions should only occur when RST# is low. This protects the device
from accidental programming or erasure during power transitions.
12.2
Reset Specifications
Asserting RST# during a system reset is important with automated program/erase
devices because systems typically expect to read from flash memory when coming out
of reset. If a CPU reset occurs without a flash memory reset, proper CPU initialization
may not occur. This is because the flash memory may be providing status information,
instead of array data as expected. Connect RST# to the same active low reset signal
used for CPU initialization.
Also, because the device is disabled when RST# is asserted, it ignores its control inputs
during power-up/down. Invalid bus conditions are masked, providing a level of memory
protection.
Table 23: Reset Specifications
Num
Symbol
Parameter
RST# pulse width low
Min
Max
Unit
Notes
P1
tPLPH
100
-
-
25
25
-
ns
1,2,3,4
1,3,4,7
1,3,4,7
1,4,5,6
1,4,5,6
RST# low to device reset during erase
P2
P3
tPLRH
RST# low to device reset during program
VCC Power valid to RST# de-assertion (high) 130nm
-
µs
60
300
tVCCPH
V
CC Power valid to RST# de-assertion (high) 65nm
-
Notes:
1.
2.
3.
4.
5.
6.
7.
These specifications are valid for all device versions (packages and speeds).
The device may reset if tPLPH is < tPLPH MIN, but this is not guaranteed.
Not applicable if RST# is tied to Vcc.
Sampled, but not 100% tested.
When RST# is tied to the VCC supply, device will not be ready until tVCCPH after VCC ≥ VCCMIN
When RST# is tied to the VCCQ supply, device will not be ready until tVCCPH after VCC ≥ VCCMIN
Reset completes within tPLPH if RST# is asserted while no erase or program operation is executing.
.
.
August 2008
Order Number: 306666-12
Datasheet
49
P30
Figure 17: Reset Operation Waveforms
P1
P2
P2
P3
R5
VIH
VIL
(
A) Reset during
RST# [P]
RST# [P]
RST# [P]
VCC
read mode
Abort
Complete
R5
(B) Reset during
VIH
VIL
program or block erase
P1
≤ P2
Abort
Complete
R5
(C) Reset during
VIH
VIL
program or block erase
P1
≥ P2
VCC
0V
(D) VCC Power-up to
RST# high
12.3
Power Supply Decoupling
Flash memory devices require careful power supply de-coupling. Three basic power
supply current considerations are 1) standby current levels, 2) active current levels,
and 3) transient peaks produced when CE# and OE# are asserted and deasserted.
When the device is accessed, many internal conditions change. Circuits within the
device enable charge-pumps, and internal logic states change at high speed. All of
these internal activities produce transient signals. Transient current magnitudes depend
on the device outputs’ capacitive and inductive loading. Two-line control and correct
de-coupling capacitor selection suppress transient voltage peaks.
Because Numonyx Multi-Level Cell (MLC) flash memory devices draw their power from
VCC, VPP, and VCCQ, each power connection should have a 0.1 µF ceramic capacitor to
ground. High-frequency, inherently low-inductance capacitors should be placed as close
as possible to package leads.
Additionally, for every eight devices used in the system, a 4.7 µF electrolytic capacitor
should be placed between power and ground close to the devices. The bulk capacitor is
meant to overcome voltage droop caused by PCB trace inductance.
Datasheet
50
August 2008
306666-12
P30
13.0
Maximum Ratings and Operating Conditions
13.1
Absolute Maximum Ratings
Warning:
Stressing the device beyond the “Absolute Maximum Ratings” may cause permanent
damage. These are stress ratings only.
Table 24: Maximum Ratings
Parameter
Maximum Rating
Notes
Temperature under bias
Storage temperature
Voltage on any signal (except VCC, VPP and VCCQ)
VPP voltage
–40 °C to +85 °C
–65 °C to +125 °C
–0.5 V to +4.1 V
–0.2 V to +10 V
–0.2 V to +2.5 V
–0.2 V to +4.1 V
100 mA
1
1,2,3
VCC voltage
1
1
4
VCCQ voltage
Output short circuit current
Notes:
1.
Voltages shown are specified with respect to VSS. Minimum DC voltage is –0.5 V on input/output signals and –0.2 V on
VCC, VCCQ, and VPP. During transitions, this level may undershoot to –2.0 V for periods less than 20 ns. Maximum DC
voltage on VCC is VCC + 0.5 V, which, during transitions, may overshoot to VCC + 2.0 V for periods less than 20 ns.
Maximum DC voltage on input/output signals and VCCQ is VCCQ + 0.5 V, which, during transitions, may overshoot to
VCCQ + 2.0 V for periods less than 20 ns.
2.
3.
Maximum DC voltage on VPP may overshoot to +11.5 V for periods less than 20 ns.
Program/erase voltage is typically 1.7 V – 2.0 V. 9.0 V can be applied for 80 hours maximum total, to any blocks for
1000 cycles maximum. 9.0 V program/erase voltage may reduce block cycling capability.
4.
Output shorted for no more than one second. No more than one output shorted at a time.
13.2
Operating Conditions
Note: Operation beyond the “Operating Conditions” is not recommended and extended exposure
beyond the “Operating Conditions” may affect device reliability.
Table 25: Operating Conditions
Symbol
Parameter
Min
Max
Units
Notes
TC
Operating Temperature
VCC Supply Voltage
–40
+85
2.0
3.6
3.6
3.6
9.5
80
°C
1
3
VCC
1.7
CMOS inputs
TTL inputs
1.7
VCCQ
I/O Supply Voltage
2.4
V
VPPL
VPPH
tPPH
VPP Voltage Supply (Logic Level)
Factory word programming VPP
Maximum VPP Hours
0.9
8.5
VPP = VPPH
VPP = VPPL
VPP = VPPH
VPP = VPPH
-
Hours
Cycles
2
Main and Parameter Blocks
Main Blocks
100,000
-
Block
Erase
Cycles
-
-
1000
2500
Parameter Blocks
Notes:
1.
2.
3.
T
C = Case Temperature.
In typical operation VPP program voltage is VPPL
.
40Mhz burst operation on the TSOP package has a min Vcc value of 1.85V. Please refer to the latest Specification Update
regarding synchronous burst operation with the TSOP package
August 2008
Order Number: 306666-12
Datasheet
51
P30
14.0
Electrical Specifications
14.1
DC Current Characteristics
Table 26: DC Current Characteristics (Sheet 1 of 2)
CMOS
TTL Inputs
Inputs
(VCCQ
2.4 V - 3.6
V)
=
(VCCQ
1.7 V - 3.6
V)
=
Sym
Parameter
Unit
Test Conditions
Notes
Typ
Max
Typ
Max
VCC = VCCMax
VCCQ = VCCQMax
VIN = VCCQ or VSS
ILI
Input Load Current
-
±1
-
±2
µA
µA
1
Output
VCC = VCCMax
VCCQ = VCCQMax
VIN = VCCQ or VSS
ILO
Leakage
Current
DQ[15:0],
-
±1
-
±10
WAIT
64-Mbit
20
30
35
75
20
30
35
75
VCC = VCCMax
VCCQ = VCCQMax
CE# = VCCQ
RST# = VCCQ (for ICCS
RST# = VSS (for ICCD
WP# = VIH
128-Mbit
256-Mbit
512-Mbit
ICCS
ICCD
,
VCC Standby,
Power Down
µA
1,2
)
55
115
230
55
200
400
)
110
110
Asynchronous Single-
Word f = 5 MHz (1 CLK)
14
9
16
10
14
9
16
10
mA
mA
1-Word Read
Page-Mode Read
f = 13 MHz (5 CLK)
4-Word Read
BL = 4W
13
15
17
21
16
19
22
23
36
26
20
30
55
110
17
19
21
26
19
23
26
28
51
33
35
75
115
230
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
36
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
51
mA
mA
mA
mA
mA
mA
mA
mA
Average
VCC
VCC = VCCMax
CE# = VIL
OE# = VIH
Inputs: VIL or
VIH
BL = 8W
Synchronous Burst
f = 40 MHz
ICCR
Read
1
BL = 16W
BL = Cont.
BL = 4W
Current
BL = 8W
Synchronous Burst
f = 52MHz
BL = 16W
BL = Cont.
VPP = VPPL, pgm/ers in progress
VPP = VPPH, pgm/ers in progress
1,3,5
1,3,5
ICCW,
ICCE
VCC Program Current,
VCC Erase Current
mA
26
33
64-Mbit
128-Mbit
256-Mbit
512-Mbit
20
35
VCC Program Suspend
30
75
ICCWS, Current,
CE# = VCCQ; suspend in
progress
µA
1,3,4
ICCES
VCC Erase
55
200
400
Suspend Current
110
IPPS,
VPP Standby Current,
IPPWS, VPP Program Suspend Current,
0.2
5
0.2
5
µA
VPP = VPPL, suspend in progress
1,3
1,3
VPP Erase Suspend Current
IPPES
IPPR
VPP Read
2
0.05
8
15
0.10
22
2
0.05
8
15
0.10
22
µA
VPP = VPPL
VPP = VPPL, program in progress
VPP = VPPH, program in progress
IPPW
VPP Program Current
mA
Datasheet
52
August 2008
306666-12
P30
Table 26: DC Current Characteristics (Sheet 2 of 2)
CMOS
TTL Inputs
Inputs
(VCCQ
2.4 V - 3.6
V)
=
(VCCQ
1.7 V - 3.6
V)
=
Sym
Parameter
Unit
Test Conditions
Notes
Typ
Max
Typ
Max
0.05
8
0.10
22
0.05
8
0.10
22
VPP = VPPL, erase in progress
IPPE
VPP Erase Current
mA
V
PP = VPPH, erase in progress
Notes:
1.
2.
3.
4.
5.
All currents are RMS unless noted. Typical values at typical VCC, TC = +25 °C.
ICCS is the average current measured over any 5 ms time interval 5 µs after CE# is deasserted.
Sampled, not 100% tested.
ICCES is specified with the device deselected. If device is read while in erase suspend, current is ICCES plus ICCR
ICCW, ICCE measured over typical or max times specified in Section 16.0, “Program and Erase
Characteristics” on page 66.
.
14.2
DC Voltage Characteristics
Table 27: DC Voltage Characteristics
(1)
CMOS Inputs
(VCCQ = 1.7 V – 3.6 V)
TTL Inputs
(VCCQ = 2.4 V – 3.6 V)
Sym
Parameter
Unit
Test Condition
Notes
Min
Max
Min
Max
VIL
Input Low Voltage
Input High Voltage
0
0.4
0
0.6
V
V
2
VIH
VCCQ – 0.4 V
VCCQ
2.0
VCCQ
VCC = VCCMin
VCCQ = VCCQMin
IOL = 100 µA
VOL
Output Low Voltage
Output High Voltage
-
0.1
-
-
0.1
-
V
V
VCC = VCCMin
VCCQ = VCCQMin
IOH = –100 µA
VOH
VCCQ – 0.1
VCCQ – 0.1
VPPLK
VLKO
VPP Lock-Out Voltage
VCC Lock Voltage
-
0.4
-
0.4
V
V
V
3
1.0
0.9
-
-
1.0
0.9
-
-
VLKOQ
VCCQ Lock Voltage
Notes:
1.
2.
3.
Synchronous read mode is not supported with TTL inputs.
VIL can undershoot to –0.4 V and VIH can overshoot to VCCQ + 0.4 V for durations of 20 ns or less.
VPP ≤ VPPLK inhibits erase and program operations. Do not use VPPL and VPPH outside their valid ranges.
August 2008
Order Number: 306666-12
Datasheet
53
P30
15.0
AC Characteristics
15.1
AC Test Conditions
Figure 18: AC Input/Output Reference Waveform
VCCQ
Input VCCQ/2
Test Points
VCCQ/2 Output
0V
IO_REF.WMF
Note: AC test inputs are driven at VCCQ for Logic "1" and 0 V for Logic "0." Input/output timing begins/ends at VCCQ/2. Input rise
and fall times (10% to 90%) < 5 ns. Worst case speed occurs at VCC = VCCMin.
Figure 19: Transient Equivalent Testing Load Circuit
Device
Out
Under Test
CL
Notes:
1.
2.
See the following table for component values.
Test configuration component value for worst-case speed conditions.
CL includes jig capacitance.
3.
.
Table 28: Test Configuration Component Value For Worst Case Speed Conditions
Test Configuration
CCQMin Standard Test
CL (pF)
V
30
Figure 20: Clock Input AC Waveform
R201
VIH
CLK [C]
VIL
R202
R203
Datasheet
54
August 2008
306666-12
P30
15.2
Capacitance
Table 29: Capacitance
Parameter
Signals
Min
Typ
Max
Unit
Condition
Notes
Address, Data,
CE#, WE#, OE#,
RST#, CLK, ADV#,
WP#
Typ temp = 25 °C,
Max temp = 85 °C,
VCC = (0 V - 2.0 V),
VCCQ = (0 V - 3.6 V),
Discrete silicon die
Input Capacitance
Output Capacitance
2
2
6
4
7
5
pF
pF
1,2,3
Data, WAIT
Notes:
1.
Capacitance values are for a single die; for 2-die and 4-die stacks, multiply the capacitance values by the number of
dies in the stack.
2.
3.
Sampled, but not 100% tested.
Silicon die capacitance only; add 1 pF for discrete packages.
15.3
AC Read Specifications
Table 30: AC Read Specifications for 64/128- Mbit Densities (Sheet 1 of 2)
Num
Symbol
Parameter
Min
Max
Unit
Notes
Asynchronous Specifications
R1
R2
R3
R4
R5
R6
R7
R8
R9
tAVAV
tAVQV
tELQV
tGLQV
tPHQV
tELQX
tGLQX
tEHQZ
tGHQZ
Read cycle time
85
-
-
85
85
25
150
-
ns
ns
ns
ns
ns
ns
ns
ns
ns
Address to output valid
CE# low to output valid
OE# low to output valid
-
-
1,2
1
RST# high to output valid
CE# low to output in low-Z
OE# low to output in low-Z
CE# high to output in high-Z
OE# high to output in high-Z
-
0
0
-
1,3
1,2,3
-
24
24
-
1,3
Output hold from first occurring address, CE#, or
OE# change
R10
tOH
0
-
ns
R11
R12
R13
R15
tEHEL
tELTV
tEHTZ
tGLTV
CE# pulse width high
20
-
-
ns
ns
ns
ns
ns
ns
1
CE# low to WAIT valid
CE# high to WAIT high-Z
OE# low to WAIT valid
OE# low to WAIT in low-Z
OE# high to WAIT in high-Z
17
20
17
-
-
1,3
1
-
R16
R17
tGLTX
tGHTZ
0
-
1,3
20
Latching Specifications
R101
R102
R103
R104
R105
R106
tAVVH
tELVH
tVLQV
tVLVH
tVHVL
tVHAX
Address setup to ADV# high
CE# low to ADV# high
10
10
-
-
-
ns
ns
ns
ns
ns
ns
ADV# low to output valid
ADV# pulse width low
85
-
1
10
10
9
ADV# pulse width high
Address hold from ADV# high
-
-
1,4
August 2008
Order Number: 306666-12
Datasheet
55
P30
Table 30: AC Read Specifications for 64/128- Mbit Densities (Sheet 2 of 2)
Num
Symbol
Parameter
Min
Max
Unit
Notes
R108
R111
tAPA
tphvh
Page address access
-
25
-
ns
ns
1
RST# high to ADV# high
30
Clock Specifications
-
-
52
40
-
MHz
MHz
ns
R200
R201
fCLK
CLK frequency
CLK period
TSOP
TSOP
19.2
25
5
tCLK
1,3,5,6
-
ns
R202
R203
tCH/CL
CLK high/low time
CLK fall/rise time
-
ns
tFCLK/RCLK
-
3
ns
Synchronous Specifications(5,6)
R301
R302
R303
R304
R305
R306
R307
R311
R312
tAVCH/L
tVLCH/L
tELCH/L
tCHQV / tCLQV
tCHQX
Address setup to CLK
ADV# low setup to CLK
CE# low setup to CLK
CLK to output valid
9
9
-
-
ns
ns
ns
ns
ns
ns
ns
ns
ns
1
9
-
-
17
-
Output hold from CLK
Address hold from CLK
CLK to WAIT valid
3
1,7
1,4,7
1,7
1
tCHAX
10
-
-
tCHTV
17
-
tCHVL
CLK Valid to ADV# Setup
WAIT Hold from CLK
3
tCHTX
3
-
1,7
Notes:
1.
See Figure 18, “AC Input/Output Reference Waveform” on page 54 for timing measurements and max
allowable input slew rate.
2.
3.
4.
5.
6.
7.
OE# may be delayed by up to tELQV – tGLQV after CE#’s falling edge without impact to tELQV.
Sampled, not 100% tested.
Address hold in synchronous burst mode is tCHAX or tVHAX, whichever timing specification is satisfied first.
Please see the latest P30 Spec Update for synchronous burst operation with the TSOP package.
Synchronous read mode is not supported with TTL level inputs.
Applies only to subsequent synchronous reads.
Table 31: AC Read Specifications for 256/512-Mbit Densities (Sheet 1 of 3)
Num
Symbol
Parameter
Speed
Min
Max
Unit
Notes
Asynchronous Specifications
VCC = 1.8 V – 2.0
85
88
95
-
-
-
V
VCC = 1.7 V – 2.0
V
R1
R2
tAVAV
Read cycle time
ns
256/512-Mb TSOP
packages
VCC = 1.8 V – 2.0
V
85
88
95
VCC = 1.7 V – 2.0
V
tAVQV
Address to output valid
-
ns
256/512-Mb TSOP
packages
-
Datasheet
56
August 2008
306666-12
P30
Table 31: AC Read Specifications for 256/512-Mbit Densities (Sheet 2 of 3)
Num
Symbol
Parameter
Speed
Min
Max
Unit
Notes
VCC = 1.8 V – 2.0
V
-
85
VCC = 1.7 V – 2.0
R3
tELQV
CE# low to output valid
-
-
88
95
ns
V
256/512-Mb TSOP
packages
R4
R5
R6
R7
R8
R9
tGLQV
tPHQV
tELQX
tGLQX
tEHQZ
tGHQZ
OE# low to output valid
-
-
25
150
-
ns
ns
ns
ns
ns
ns
1,2
1
RST# high to output valid
CE# low to output in low-Z
OE# low to output in low-Z
CE# high to output in high-Z
OE# high to output in high-Z
0
0
-
1,3
1,2,3
-
24
24
-
1,3
Output hold from first occurring address, CE#, or OE#
change
R10
tOH
0
-
ns
R11
R12
R13
R15
tEHEL
tELTV
tEHTZ
tGLTV
CE# pulse width high
20
-
-
ns
ns
ns
ns
ns
ns
1
CE# low to WAIT valid
CE# high to WAIT high-Z
OE# low to WAIT valid
OE# low to WAIT in low-Z
OE# high to WAIT in high-Z
17
20
17
-
-
1,3
1
-
R16
R17
tGLTX
tGHTZ
0
-
1,3
20
Latching Specifications
R101
R102
tAVVH
tELVH
Address setup to ADV# high
CE# low to ADV# high
10
10
-
-
ns
ns
V
CC = 1.8 V – 2.0
-
-
-
85
88
95
V
VCC = 1.7 V – 2.0
V
R103
tVLQV
ADV# low to output valid
ns
1
256/512-Mb TSOP
packages
R104
R105
R106
R108
R111
tVLVH
tVHVL
tVHAX
tAPA
ADV# pulse width low
ADV# pulse width high
Address hold from ADV# high
Page address access
10
10
9
-
-
ns
ns
ns
ns
ns
-
1,4
1
-
25
-
tphvh
RST# high to ADV# high
30
Clock Specifications
-
-
52
40
-
MHz
MHz
ns
1,3,5,6
R200
R201
fCLK
CLK frequency
CLK period
TSOP Package
TSOP Package
19.2
25
5
tCLK
-
ns
R202
R203
tCH/CL
CLK high/low time
CLK fall/rise time
-
ns
tFCLK/RCLK
-
3
ns
Synchronous Specifications(5,6)
August 2008
Order Number: 306666-12
Datasheet
57
P30
Table 31: AC Read Specifications for 256/512-Mbit Densities (Sheet 3 of 3)
Num
R301
Symbol
tAVCH/L
Parameter
Address setup to CLK
Speed
Min
Max
Unit
Notes
9
9
-
-
ns
ns
ns
ns
ns
ns
ns
ns
ns
R302
R303
R304
R305
R306
R307
R311
R312
tVLCH/L
tELCH/L
tCHQV / tCLQV
tCHQX
ADV# low setup to CLK
CE# low setup to CLK
CLK to output valid
1
9
-
-
17
-
Output hold from CLK
Address hold from CLK
CLK to WAIT valid
3
1,7
1,4,7
1,7
1
tCHAX
10
-
-
tCHTV
17
-
tCHVL
CLK Valid to ADV# Setup
WAIT Hold from CLK
3
tCHTX
3
-
1,7
Notes:
1.
See Figure 18, “AC Input/Output Reference Waveform” on page 54 for timing measurements and max
allowable input slew rate.
2.
3.
4.
5.
6.
7.
OE# may be delayed by up to tELQV – tGLQV after CE#’s falling edge without impact to tELQV.
Sampled, not 100% tested.
Address hold in synchronous burst mode is tCHAX or tVHAX, whichever timing specification is satisfied first.
Please see the latest P30 Spec Update for synchronous burst operation with the TSOP package.
Synchronous read mode is not supported with TTL level inputs.
Applies only to subsequent synchronous reads.
Table 32: AC Read Specification differences for 65nm
Num
Symbol
Parameter
Min
Max
Unit
Notes
Asynchronous Specifications
100
110
-
-
ns
ns
ns
ns
ns
ns
ns
ns
2
2
R1
R2
tAVAV
tAVQV
tELQV
Read cycle time
TSOP
TSOP
TSOP
TSOP
100
110
100
110
100
110
2
Address to output valid
2
-
-
2
R3
CE# low to output valid
tVLQV
2
1,2
2
R103
ADV# low to output valid
Notes:
1.
See Figure 18, “AC Input/Output Reference Waveform” on page 54 for timing measurements and
max allowable input slew rate.
2.
This is the recommended specification for all new designs supporting both 130nm and 65nm lithos, or for new designs
that will use the 65nm lithography.
Datasheet
58
August 2008
306666-12
P30
Figure 21: Asynchronous Single-Word Read (ADV# Low)
R1
R2
Address [A]
ADV#
R3
R8
CE# [E}
R4
R9
OE# [G]
R15
R17
WAIT [T]
R7
R6
Data [D/Q]
R5
RST# [P]
Note: WAIT shown deasserted during asynchronous read mode (RCR[10]=0, Wait asserted low).
Figure 22: Asynchronous Single-Word Read (ADV# Latch)
R1
R2
Address [A]
A[1:0][A]
R101
R105
R106
ADV#
CE# [E}
OE# [G]
WAIT [T]
R3
R8
R4
R9
R15
R17
R7
R6
R10
Data [D/Q]
Note: WAIT shown deasserted during asynchronous read mode (RCR[10]=0, Wait asserted low).
August 2008
Order Number: 306666-12
Datasheet
59
P30
Figure 23: Asynchronous Page-Mode Read Timing
R1
R2
A[Max:2] [A]
A[1:0]
R101
R105
R106
ADV#
CE# [E]
R3
R8
R4
R10
OE# [G]
R15
R17
WAIT [T]
R7
R9
R108
DATA [D/Q]
Note: WAIT shown deasserted during asynchronous read mode (RCR[10]=0, Wait asserted low).
Figure 24: Synchronous Single-Word Array or Non-array Read Timing
R301
R306
CLK [C]
R2
Address [A]
R101
R104
R106
R105
ADV# [V]
R303
R102
R3
R8
CE# [E]
OE# [G]
WAIT [T]
R7
R9
R15
R307
R304
R17
R312
R4
R305
Data [D/Q]
1.
2.
WAIT is driven per OE# assertion during synchronous array or non-array read, and can be configured to assert either
during or one data cycle before valid data.
This diagram illustrates the case in which an n-word burst is initiated to the flash memory array and it is terminated by
CE# deassertion after the first word in the burst.
Datasheet
60
August 2008
306666-12
P30
Figure 25: Continuous Burst Read, Showing An Output Delay Timing
R301
R302
R306
R304
R304
R304
CLK [C]
Address [A]
ADV# [V]
R2
R101
R106
R105
R303
R102
R3
CE# [E]
OE# [G]
R15
R307
R304
R312
WAIT [T]
R4
R7
R305
R305
R305
R305
Data [D/Q]
Notes:
1.
WAIT is driven per OE# assertion during synchronous array or non-array read, and can be configured to assert either
during or one data cycle before valid data.
At the end of Word Line; the delay incurred when a burst access crosses a 16-word boundary and the starting address is
not 4-word boundary aligned.
2.
Figure 26: Synchronous Burst-Mode Four-Word Read Timing
R302
R301
R306
CLK [C]
Address [A]
ADV# [V]
R2
R101
A
R105
R102
R106
R303
R3
R8
CE# [E]
OE# [G]
WAIT [T]
R9
R15
R17
R307
R4
R304
R305
Q0
R7
R304
R10
Data [D/Q]
Q1
Q2
Q3
Note: WAIT is driven per OE# assertion during synchronous array or non-array read. WAIT asserted during initial latency and
deasserted during valid data (RCR[10] = 0, Wait asserted low).
August 2008
Order Number: 306666-12
Datasheet
61
P30
15.4
AC Write Specifications
Table 33: AC Write Specifications
Num
W1
Symbol
tPHWL
Parameter
Min
Max
Unit
Notes
RST# high recovery to WE# low
CE# setup to WE# low
150
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
1,2,3
1,2,3
1,2,4
W2
tELWL
0
W3
tWLWH
tDVWH
tAVWH
tWHEH
tWHDX
tWHAX
tWHWL
tVPWH
tQVVL
WE# write pulse width low
Data setup to WE# high
Address setup to WE# high
CE# hold from WE# high
Data hold from WE# high
Address hold from WE# high
WE# pulse width high
50
W4
50
W5
50
W6
0
1,2
W7
0
W8
0
W9
20
1,2,5
W10
W11
W12
W13
W14
W16
VPP setup to WE# high
200
1,2,3,7
1,2,3,7
VPP hold from Status read
WP# hold from Status read
WP# setup to WE# high
WE# high to OE# low
0
tQVBL
0
200
tBHWH
tWHGL
tWHQV
0
1,2,9
WE# high to read valid
tAVQV + 35
1,2,3,6,10
Write to Asynchronous Read Specifications
W18 tWHAV WE# high to Address valid
Write to Synchronous Read Specifications
0
-
ns
1,2,3,6,8
W19
W20
tWHCH/L
tWHVH
WE# high to Clock valid
WE# high to ADV# high
19
19
-
-
ns
ns
1,2,3,6,10
Write Specifications with Clock Active
W21
W22
tVHWL
tCHWL
ADV# high to WE# low
Clock high to WE# low
-
-
20
20
ns
ns
1,2,3,11
Notes:
1.
2.
3.
4.
Write timing characteristics during erase suspend are the same as write-only operations.
A write operation can be terminated with either CE# or WE#.
Sampled, not 100% tested.
Write pulse width low (tWLWH or tELEH) is defined from CE# or WE# low (whichever occurs last) to CE# or WE# high
(whichever occurs first). Hence, tWLWH = tELEH = tWLEH = tELWH
.
5.
Write pulse width high (tWHWL or tEHEL) is defined from CE# or WE# high (whichever occurs first) to CE# or WE# low
(whichever occurs last). Hence, tWHWL = tEHEL = tWHEL = tEHWL).
6.
7.
8.
tWHVH or tWHCH/L must be met when transitioning from a write cycle to a synchronous burst read.
VPP and WP# should be at a valid level until erase or program success is determined.
This specification is only applicable when transitioning from a write cycle to an asynchronous read. See spec W19 and
W20 for synchronous read.
When doing a Read Status operation following any command that alters the Status Register, W14 is 20 ns.
Add 10 ns if the write operation results in a RCR or block lock status change, for the subsequent read operation to reflect
this change.
9.
10.
11.
These specs are required only when the device is in a synchronous mode and clock is active during address setup phase.
Datasheet
62
August 2008
306666-12
P30
Figure 27: Write-to-Write Timing
W5
W8
W5
W8
Address [A]
W2
W6
W2
W6
CE# [E}
W3
W9
W3
WE# [W]
OE# [G]
W4
W7
W4
W7
Data [D/Q]
W1
RST# [P]
Figure 28: Asynchronous Read-to-Write Timing
R1
R2
W5
W8
Address [A]
R3
R8
R9
CE# [E}
R4
OE# [G]
W2
W3
W6
WE# [W]
R15
R17
WAIT [T]
R7
R6
W7
R10
W4
Data [D/Q]
RST# [P]
Q
D
R5
Note: WAIT deasserted during asynchronous read and during write. WAIT High-Z during write per OE# deasserted.
August 2008
Order Number: 306666-12
Datasheet
63
P30
Figure 29: Write-to-Asynchronous Read Timing
W5
W8
R1
Address [A]
ADV# [V]
W2
W6
R10
CE# [E}
WE# [W]
OE# [G]
WAIT [T]
W3
W18
W14
R15
R17
R4
R2
R3
R8
W4
W7
R9
Data [D/Q]
RST# [P]
D
Q
W1
Figure 30: Synchronous Read-to-Write Timing
Latency Count
R301
R302
R306
CLK [C]
R2
W5
R101
W18
Address [A]
R105
R102
R106
R104
ADV# [V]
R303
R11
R13
R3
W6
CE# [E]
OE# [G]
R4
R8
W21
W22
W21
W22
W2
W8
W15
W3
W9
WE#
R16
R307
R304
R312
WAIT [T]
R7
R305
W7
Q
D
D
Data [D/Q]
Note: WAIT shown deasserted and High-Z per OE# deassertion during write operation (RCR[10]=0, Wait asserted low). Clock is
ignored during write operation.
Datasheet
64
August 2008
306666-12
P30
Figure 31: Write-to-Synchronous Read Timing
R302
R301
R2
CLK
W5
W8
R306
R106
Address [A]
R104
R303
ADV#
W6
W2
R11
CE# [E}
W18
W19
W20
W3
WE# [W]
OE# [G]
WAIT [T]
R4
R15
R3
R307
W7
R304
R305
R304
W4
D
Q
Q
Data [D/Q]
RST# [P]
W1
Note: WAIT shown deasserted and High-Z per OE# deassertion during write operation (RCR[10]=0, Wait asserted low).
August 2008
Order Number: 306666-12
Datasheet
65
P30
16.0
Program and Erase Characteristics
Table 34: Program and Erase Specifications
VPPL
Typ
VPPH
Typ
Num
Symbol
Parameter
Units
Notes
Min
Max
Min
Max
Conventional Word Programming
Single word - 130nm
Single word - 65nm
Single cell
-
-
-
90
150
30
200
456
60
-
-
-
85
150
30
190
456
60
Program
Time
W200
tPROG/W
µs
1
1
Buffered Programming
W200
W251
tPROG/W
tBUFF
Single word
-
-
90
440
200
880
-
-
85
190
680
Program
Time
µs
µs
32-word buffer
340
Buffered Enhanced Factory Programming
W451
W452
tBEFP/W
Single word
BEFP Setup
n/a
n/a
n/a
n/a
n/a
n/a
-
10
-
-
-
1,2
1
Program
tBEFP/Setup
5
Erasing and Suspending
W500
W501
W600
W601
W602
tERS/PB
tERS/MB
tSUSP/P
tSUSP/E
tERS/SUSP
32-KByte Parameter
128-KByte Main
Program suspend
Erase suspend
-
-
-
-
-
0.4
1.2
20
2.5
4.0
25
25
-
-
-
-
-
-
0.4
1.0
20
2.5
4.0
25
25
-
Erase Time
s
1
Suspend
Latency
20
20
µs
Erase to Suspend
500
500
1,3
Notes:
1.
Typical values measured at TC = +25 °C and nominal voltages. Performance numbers are valid for all speed versions. Excludes system
overhead. Sampled, but not 100% tested.
2.
3.
Averaged over entire device.
W602 is the typical time between an initial block erase or erase resume command and the a subsequent erase suspend
command. Violating the specification repeatedly during any particular block erase may cause erase failures.
Datasheet
66
August 2008
306666-12
P30
17.0
Ordering Information
17.1
Discrete Products
Figure 32: Decoder for Discrete P30
T E 2 8 F 6 4 0 P 3 0 B 8 5
Access Speed
Package Designator
85 ns
TE = 56-Lead TSOP, leaded
JS = 56-Lead TSOP, lead-free
RC = 64-Ball Easy BGA, leaded
PC = 64-Ball Easy BGA, lead-free
Parameter Location
B = Bottom Parameter
T = Top Parameter
Product Line Designator
28F = Intel® Flash Memory
Product Family
P30 = Intel StrataFlash® Embedded Memory
VCC = 1.7 – 2.0 V
VCCQ = 1.7 – 3.6 V
Device Density
640 = 64-Mbit
128 = 128-Mbit
256 = 256-Mbit
Table 35: Valid Combinations for Discrete Products
64-Mbit
128-Mbit
256-Mbit
TE28F640P30B85
TE28F640P30T85
JS28F640P30B85
JS28F640P30T85
RC28F640P30B85
RC28F640P30T85
PC28F640P30B85
PC28F640P30T85
TE28F128P30B85
TE28F128P30T85
JS28F128P30B85
JS28F128P30T85
RC28F128P30B85
RC28F128P30T85
PC28F128P30B85
PC28F128P30T85
TE28F256P30B95
TE28F256P30T95
JS28F256P30B95
JS28F256P30T95
RC28F256P30B85
RC28F256P30T85
PC28F256P30B85
PC28F256P30T85
August 2008
Order Number: 306666-12
Datasheet
67
P30
17.2
SCSP Products
Figure 33: Decoder for SCSP P30
R D 4 8 F 4 0 0 0 P 0 Z B Q 0
Package Designator
RD = Intel® SCSP, leaded
Device Details
PF = Intel® SCSP, lead-free
RC = 64-Ball Easy BGA, leaded
PC = 64-Ball Easy BGA, lead-free
TE = 56-Lead TSOP, leaded
JS = 56-Lead TSOP, lead-free
0 = Original version of the product
(refer to the latest version of the
datasheet for details)
Ballout Designator
Q = QUAD+ ballout
0 = Discrete ballout
Group Designator
48F = Flash Memory only
Flash Density
0 = No die
2 = 64-Mbit
Parameter, Mux Configuration
B = Bottom Parameter, Non Mux
T = Top Parameter, Non Mux
3 = 128-Mbit
4 = 256-Mbit
I/O Voltage, CE# Configuration
Z = Individual Chip Enable(s)
V = Virtual Chip Enable(s)
VCC = 1.7 V – 2.0 V
Product Family
P = Intel StrataFlash® Embedded Memory
0 = No die
VCCQ = 1.7 V – 3.6 V
Note: For 512-Mbit only, “B” is used for both top and bottom Parameter/Mux configurations.
Table 36: Valid Combinations for Dual- Die Products
64-Mbit
128-Mbit
256-Mbit
512-Mbit*
RD48F2000P0ZBQ0
RD48F2000P0ZTQ0
PF48F2000P0ZBQ0
PF48F2000P0ZTQ0
RD48F3000P0ZBQ0
RD48F3000P0ZTQ0
PF48F3000P0ZBQ0
PF48F3000P0ZTQ0
RD48F4000P0ZBQ0
RD48F4000P0ZTQ0
PF48F4000P0ZBQ0
PF48F4000P0ZTQ0
RD48F4400P0VBQ0
PF48F4400P0VBQ0
RC48F4400P0VB00
PC48F4400P0VB00
TE48F4400P0VB00
JS48F4400P0VB00
Note: * The “B” parameter is used for both “top” and “bottom” options in the 512-Mbit density.
Datasheet
68
August 2008
306666-12
P30
Appendix A Supplemental Reference Information
A.1
Common Flash Interface Tables
The Common Flash Interface (CFI) is part of an overall specification for multiple
command-set and control-interface descriptions. This appendix describes the database
structure containing the data returned by a read operation after issuing the Read CFI
command (see Section 6.0, “Command Set” on page 23). System software can parse
this database structure to obtain information about the flash device, such as block size,
density, bus width, and electrical specifications. The system software will then know
which command set(s) to use to properly perform flash writes, block erases, reads and
otherwise control the flash device.
A.1.1
CFI Structure Output
The CFI database allows system software to obtain information for controlling the flash
device. This section describes the device’s CFI-compliant interface that allows access to
CFI data.
CFI data are presented on the lowest-order data outputs (DQ7-0) only. The numerical
offset value is the address relative to the maximum bus width supported by the device.
On this family of devices, the CFI table device starting address is a 10h, which is a word
address for x16 devices.
For a word-wide (x16) device, the first two CFI-structure bytes, ASCII “Q” and “R,”
appear on the low byte at word addresses 10h and 11h. This CFI-compliant device
outputs 00h data on upper bytes. The device outputs ASCII “Q” in the low byte (DQ7-0
)
and 00h in the high byte (DQ15-8).
At CFI addresses containing two or more bytes of information, the least significant data
byte is presented at the lower address, and the most significant data byte is presented
at the higher address.
In all of the following tables, addresses and data are represented in hexadecimal
notation, so the “h” suffix has been dropped. In addition, since the upper byte of word-
wide devices is always “00h,” the leading “00” has been dropped from the table
notation and only the lower byte value is shown. Any x16 device outputs can be
assumed to have 00h on the upper byte in this mode.
Table 37: Summary of CFI Structure Output as a Function of Device and Mode
Hex
Hex
Code
51
52
59
ASCII
Value
"Q"
"R"
"Y"
Device
Offset
00010:
00011:
00012:
Device Addresses
August 2008
Order Number: 306666-12
Datasheet
69
P30
Table 38: Example of CFI Structure Output of x16- Devices
Word Addressing:
Byte Addressing:
Offset
AX–A0
Hex Code
Value
Offset
AX–A0
Hex Code
D7–D0
51
52
59
P_IDLO
P_IDLO
P_IDHI
...
Value
D15–D0
00010h
00011h
00012h
00013h
00014h
00015h
00016h
00017h
00018h
...
0051
0052
0059
P_IDLO
P_IDHI
PLO
"Q"
"R"
"Y"
00010h
00011h
00012h
00013h
00014h
00015h
00016h
00017h
00018h
...
"Q"
"R"
"Y"
PrVendor
ID #
PrVendor
TblAdr
AltVendor
ID #
PrVendor
ID #
ID #
PHI
...
A_IDLO
A_IDHI
...
...
A.1.2
CFI Structure Overview
The CFI command causes the flash component to display the Common Flash Interface
(CFI) CFI structure or “database.” The structure sub-sections and address locations are
summarized below.
Table 39: CFI Structure
Description(1)
Offset
Sub-Section Name
00001-Fh Reserved
Reserved for vendor-specific information
Command set ID and vendor data offset
Device timing & voltage information
Flash device layout
00010h
0001Bh
00027h
CFI query identification string
System interface information
Device geometry definition
Vendor-defined additional information specific
to the Primary Vendor Algorithm
P(3)
Primary Intel-specific Extended Query Table
Notes:
1.
Refer to the CFI Structure Output section and offset 28h for the detailed definition of offset address as a function of device
bus width and mode.
2.
3.
BA = Block Address beginning location (i.e., 08000h is block 1’s beginning location when the block size is 32-KWord).
Offset 15 defines “P” which points to the Primary Numonyx-specific Extended CFI Table.
A.1.3
Read CFI Identification String
The Identification String provides verification that the component supports the
Common Flash Interface specification. It also indicates the specification version and
supported vendor-specified command set(s).
Table 40: CFI Identification
Hex
Offset Length
Description
Query-unique ASCII string “QRY“
Add. Code Value
3
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
1A:
10h
--51
--52
--59
--01
--00
--0A
--01
--00
--00
--00
--00
"Q"
"R"
"Y"
2
2
2
2
Primary vendor command set and control interface ID code.
16-bit ID code for vendor-specified algorithms
Extended Query Table primary algorithm address
13h
15h
17h
19h
Alternate vendor command set and control interface ID code.
0000h means no second vendor-specified algorithm exists
Secondary algorithm Extended Query Table address.
0000h means none exists
Datasheet
70
August 2008
306666-12
P30
Table 41: System Interface Information
Hex
Code
--17
Offset
Length
Description
Add.
1B:
Value
1.7V
1Bh
1
V
CC logic supply minimum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 BCD volts
1Ch
1Dh
1Eh
1
1
1
VCC logic supply maximum program/erase voltage
1C:
1D:
1E:
--20
--85
--95
2.0V
8.5V
9.5V
bits 0–3 BCD 100 mV
bits 4–7 BCD volts
V
PP [programming] supply minimum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 HEX volts
VPP [programming] supply maximum program/erase voltage
bits 0–3 BCD 100 mV
bits 4–7 HEX volts
“n” such that typical single word program time-out = 2n μ-sec
“n” such that typical max. buffer write time-out = 2n μ-sec
“n” such that typical block erase time-out = 2n m-sec
“n” such that typical full chip erase time-out = 2n m-sec
“n” such that maximum word program time-out = 2n times typical
“n” such that maximum buffer write time-out = 2n times typical
“n” such that maximum block erase time-out = 2n times typical
“n” such that maximum chip erase time-out = 2n times typical
1Fh
20h
21h
22h
23h
24h
25h
26h
1
1
1
1
1
1
1
1
1F:
20:
21:
22:
23:
24:
25:
26:
--08 256μs
--09 512μs
--0A
--00
1s
NA
--01 512μs
--01 1024μs
--02
--00
4s
NA
August 2008
Order Number: 306666-12
Datasheet
71
P30
A.1.4
Device Geometry Definition
Table 42: Device Geometry Definition
Offset
27h
Length
Description
Code
See table below
“n” such that device size = 2n in number of bytes
Flash device interface code assignment:
1
27:
28:
"n" such that n+1 specifies the bit field that represents the flash
device width capabilities as described in the table:
7
6
5
4
3
2
1
x16
9
0
x8
8
28h
2
—
15
—
—
14
—
—
13
—
—
12
—
x64
11
x32
10
--01
x16
64
—
—
—
—
29:
2A:
2B:
2C:
--00
--06
--00
“n” such that maximum number of bytes in write buffer = 2n
2
1
2Ah
2Ch
Number of erase block regions (x) within device:
1. x = 0 means no erase blocking; the device erases in bulk
2. x specifies the number of device regions with one or
more contiguous same-size erase blocks.
See table below
3. Symmetrically blocked partitions have one blocking region
Erase Block Region 1 Information
bits 0–15 = y, y+1 = number of identical-size erase blocks
bits 16–31 = z, region erase block(s) size are z x 256 bytes
4
4
4
2Dh
31h
35h
2D:
2E:
2F:
30:
31:
32:
33:
34:
35:
36:
37:
38:
See table below
See table below
See table below
Erase Block Region 2 Information
bits 0–15 = y, y+1 = number of identical-size erase blocks
bits 16–31 = z, region erase block(s) size are z x 256 bytes
Reserved for future erase block region information
Address
64-Mbit
128-Mbit
256-Mbit
–B
–T
–B
–T
–B
–T
27:
28:
29:
2A:
2B:
2C:
2D:
2E:
2F:
30:
31:
32:
33:
34:
35:
36:
37:
38:
--17
--01
--00
--06
--00
--02
--03
--00
--80
--00
--3E
--00
--00
--02
--00
--00
--00
--00
--17
--01
--00
--06
--00
--02
--3E
--00
--00
--02
--03
--00
--80
--00
--00
--00
--00
--00
--18
--01
--00
--06
--00
--02
--03
--00
--80
--00
--7E
--00
--00
--02
--00
--00
--00
--00
--18
--01
--00
--06
--00
--02
--7E
--00
--00
--02
--03
--00
--80
--00
--00
--00
--00
--00
--19
--01
--00
--06
--00
--02
--03
--00
--80
--00
--FE
--00
--00
--02
--00
--00
--00
--00
--19
--01
--00
--06
--00
--02
--FE
--00
--00
--02
--03
--00
--80
--00
--00
--00
--00
--00
Datasheet
72
August 2008
306666-12
P30
A.1.5
Numonyx-Specific Extended CFI Table
Table 43: Primary Vendor-Specific Extended CFI
Offset(1)
Hex
Length
Description
P = 10Ah
(Optional flash features and commands)
Add. Code Value
(P+0)h
(P+1)h
(P+2)h
(P+3)h
(P+4)h
(P+5)h
(P+6)h
(P+7)h
(P+8)h
3
Primary extended query table
Unique ASCII string “PRI“
10A
10B:
10C:
10D:
10E:
10F:
110:
111:
--50
--52
--49
--31
--34
--E6
--01
--00
"P"
"R"
"I"
"1"
"4"
1
1
4
Major version number, ASCII
Minor version number, ASCII
Optional feature and command support (1=yes, 0=no)
bits 11–29 are reserved; undefined bits are “0.” If bit 31 is
“1” then another 31 bit field of Optional features follows at
the end of the bit–30 field.
112: See table below
bit 0 Chip erase supported
bit 1 Suspend erase supported
bit 2 Suspend program supported
bit 3 Legacy lock/unlock supported
bit 4 Queued erase supported
bit 5 Instant individual block locking supported
bit 6 Protection bits supported
bit 7 Pagemode read supported
bit 8 Synchronous read supported
bit 9 Simultaneous operations supported
bit 10 Extended Flash Array Blocks supported
bit 0 = 0
bit 1 = 1
bit 2 = 1
bit 3 = 0
bit 4 = 0
bit 5 = 1
bit 6 = 1
bit 7 = 1
bit 8 = 1
bit 9 = 0
bit 10 = 0
No
Yes
Yes
No
No
Yes
Yes
Yes
Yes
No
No
See
table
below
bit 30 CFI Link(s) to follow
bit 30
bit 31
bit 31 Another "Optional Features" field to follow
(P+9)h
1
2
Supported functions after suspend: read Array, Status, Query
Other supported operations are:
bits 1–7 reserved; undefined bits are “0”
bit 0 Program supported after erase suspend
Block status register mask
bits 2–15 are Reserved; undefined bits are “0”
bit 0 Block Lock-Bit Status register active
bit 1 Block Lock-Down Bit Status active
bit 4 EFA Block Lock-Bit Status register active
bit 5 EFA Block Lock-Down Bit Status active
VCC logic supply highest performance program/erase voltage
bits 0–3 BCD value in 100 mV
bits 4–7 BCD value in volts
113:
--01
bit 0 = 1
114:
115:
Yes
(P+A)h
(P+B)h
--03
--00
bit 0 = 1
Yes
Yes
No
No
1.8V
bit 1 = 1
bit 4 = 0
bit 5 = 0
(P+C)h
(P+D)h
1
1
116:
--18
VPP optimum program/erase supply voltage
117:
--90
9.0V
bits 0–3 BCD value in 100 mV
bits 4–7 HEX value in volts
Discrete
512-Mbit
Address
112:
–B
–T
–-
–B
die 1 (B) die 2 (T) die 1 (T) die 2 (B)
--40 --00 --40 --00
–T
–-
--00
--00
August 2008
Order Number: 306666-12
Datasheet
73
P30
Table 44: Protection Register Information
Offset(1)
Length
P = 10Ah
Hex
Add. Code Value
Description
(Optional flash features and commands)
Number of Protection register fields in JEDEC ID space.
“00h,” indicates that 256 protection fields are available
Protection Field 1: Protection Description
This field describes user-available One Time Programmable
(OTP) Protection register bytes. Some are pre-programmed
with device-unique serial numbers. Others are user
programmable. Bits 0–15 point to the Protection register Lock
byte, the section’s first byte. The following bytes are factory
pre-programmed and user-programmable.
(P+E)h
1
4
118: --02
2
(P+F)h
(P+10)h
(P+11)h
(P+12)h
119: --80
11A: --00
80h
00h
11B: --03 8 byte
11C: --03 8 byte
bits 0–7 = Lock/bytes Jedec-plane physical low address
bits 8–15 = Lock/bytes Jedec-plane physical high address
bits 16–23 = “n” such that 2n = factory pre-programmed bytes
bits 24–31 = “n” such that 2n = user programmable bytes
(P+13)h
(P+14)h
(P+15)h
(P+16)h
(P+17)h
(P+18)h
(P+19)h
(P+1A)h
(P+1B)h
(P+1C)h
10
Protection Field 2: Protection Description
Bits 0–31 point to the Protection register physical Lock-word
address in the Jedec-plane.
Following bytes are factory or user-programmable.
bits 32–39 = “n” ∴ n = factory pgm'd groups (low byte)
bits 40–47 = “n” ∴ n = factory pgm'd groups (high byte)
bits 48–55 = “n” \ 2n = factory programmable bytes/group
bits 56–63 = “n” ∴ n = user pgm'd groups (low byte)
11D: --89
11E: --00
11F: --00
120: --00
89h
00h
00h
00h
0
0
0
16
0
16
--00
--00
--00
121:
122:
123:
124: --10
--00
125:
126:
∴
bits 64–71 = “n” n = user pgm'd groups (high byte)
n
∴
bits 72–79 = “n” 2 = user programmable bytes/group
--04
Table 45: Burst Read Information
Offset(1)
Hex
Length
Description
P = 10Ah
(Optional flash features and commands)
Add. Code Value
(P+1D)h
1
Page Mode Read capability
127: --03 8 byte
bits 0–7 = “n” such that 2n HEX value represents the number of
read-page bytes. See offset 28h for device word width to
determine page-mode data output width. 00h indicates no
read page buffer.
Number of synchronous mode read configuration fields that
follow. 00h indicates no burst capability.
Synchronous mode read capability configuration 1
Bits 3–7 = Reserved
(P+1E)h
(P+1F)h
1
1
128: --04
129: --01
4
4
bits 0–2 “n” such that 2n+1 HEX value represents the
maximum number of continuous synchronous reads when
the device is configured for its maximum word width. A value
of 07h indicates that the device is capable of continuous
linear bursts that will output data until the internal burst
counter reaches the end of the device’s burstable address
space. This field’s 3-bit value can be written directly to the
Read Configuration Register bits 0–2 if the device is
configured for its maximum word width. See offset 28h for
word width to determine the burst data output width.
Synchronous mode read capability configuration 2
Synchronous mode read capability configuration 3
Synchronous mode read capability configuration 4
(P+20)h
(P+21)h
(P+22)h
1
1
1
12A: --02
12B: --03
12C: --07
8
16
Cont
Datasheet
74
August 2008
306666-12
P30
Table 46: Partition and Erase Block Region Information
Offset(1)
P = 10Ah
See table below
Address
Description
Bot
Top
Bottom
Top
(Optional flash features and commands)
Len
Number of device hardware-partition regions within the device.
x = 0: a single hardware partition device (no fields follow).
x specifies the number of device partition regions containing
one or more contiguous erase block regions.
1
12D:
12D:
(P+23)h (P+23)h
Table 47: Partition Region 1 Information
Offset(1)
P = 10Ah
See table below
Address
Description
Bot
12E:
12F
130:
131:
132:
Top
Bottom
(P+24)h (P+24)h
Top
(Optional flash features and commands)
Len
2
Data size of this Parition Region Information field
(P+25)h (P+25)h (# addressable locations, including this field)
12E
12F
130:
131:
132:
Number of identical partitions within the partition region
2
1
(P+26)h (P+26)h
(P+27)h (P+27)h
(P+28)h (P+28)h Number of program or erase operations allowed in a partition
bits 0–3 = number of simultaneous Program operations
bits 4–7 = number of simultaneous Erase operations
(P+29)h (P+29)h Simultaneous program or erase operations allowed in other partitions while a
partition in this region is in Program mode
bits 0–3 = number of simultaneous Program operations
bits 4–7 = number of simultaneous Erase operations
(P+2A)h (P+2A)h Simultaneous program or erase operations allowed in other partitions while a
partition in this region is in Erase mode
1
1
1
133:
134:
135:
133:
134:
135:
bits 0–3 = number of simultaneous Program operations
bits 4–7 = number of simultaneous Erase operations
(P+2B)h (P+2B)h Types of erase block regions in this Partition Region.
x = 0 = no erase blocking; the Partition Region erases in bulk
x = number of erase block regions w/ contiguous same-size
erase blocks. Symmetrically blocked partitions have one
blocking region. Partition size = (Type 1 blocks)x(Type 1
block sizes) + (Type 2 blocks)x(Type 2 block sizes) +…+
(Type n blocks)x(Type n block sizes)
August 2008
Order Number: 306666-12
Datasheet
75
P30
Table 48: Partition Region 1 Information (continued)
Offset(1)
P = 10Ah
See table below
Address
Description
Bot
Top
136:
137:
138:
139:
13A:
13B:
13C:
Bottom
Top
(Optional flash features and commands)
Len
4
(P+2C)h (P+2C)h Partition Region 1 Erase Block Type 1 Information
(P+2D)h (P+2D)h bits 0–15 = y, y+1 = # identical-size erase blks in a partition
(P+2E)h (P+2E)h
(P+2F)h (P+2F)h
(P+30)h (P+30)h
(P+31)h (P+31)h
136:
137:
138:
139:
13A:
13B:
13C:
bits 16–31 = z, region erase block(s) size are z x 256 bytes
Partition 1 (Erase Block Type 1)
Block erase cycles x 1000
2
1
(P+32)h (P+32)h Partition 1 (erase block Type 1) bits per cell; internal EDAC
bits 0–3 = bits per cell in erase region
bit 4 = internal EDAC used (1=yes, 0=no)
bits 5–7 = reserve for future use
(P+33)h (P+33)h Partition 1 (erase block Type 1) page mode and synchronous mode capabilities
defined in Table 10.
1
6
13D:
13D:
bit 0 = page-mode host reads permitted (1=yes, 0=no)
bit 1 = synchronous host reads permitted (1=yes, 0=no)
bit 2 = synchronous host writes permitted (1=yes, 0=no)
bits 3–7 = reserved for future use
Partition Region 1 (Erase Block Type 1) Programming Region Information
(P+34)h (P+34)h
(P+35)h (P+35)h
(P+36)h (P+36)h
(P+37)h (P+37)h
(P+38)h (P+38)h
(P+39)h (P+39)h
13E:
13F:
140:
141:
142:
143:
144:
145:
146:
147:
148:
149:
14A:
bits 0–7 = x, 2^x = Programming Region aligned size (bytes)
bits 8–14 = Reserved; bit 15 = Legacy flash operation (ignore 0:7)
bits 16–23 = y = Control Mode valid size in bytes
13E:
13F:
140:
141:
142:
143:
144:
145:
146:
147:
148:
149:
14A:
bits 24-31 = Reserved
bits 32-39 = z = Control Mode invalid size in bytes
bits 40-46 = Reserved; bit 47 = Legacy flash operation (ignore 23:16 & 39:32)
(P+3A)h (P+3A)h Partition Region 1 Erase Block Type 2 Information
(P+3B)h (P+3B)h bits 0–15 = y, y+1 = # identical-size erase blks in a partition
(P+3C)h (P+3C)h bits 16–31 = z, region erase block(s) size are z x 256 bytes
(P+3D)h (P+3D)h
(P+3E)h (P+3E)h
(P+3F)h (P+3F)h
4
Partition 1 (Erase Block Type 2)
Block erase cycles x 1000
2
1
(P+40)h (P+40)h Partition 1 (erase block Type 2) bits per cell; internal EDAC
bits 0–3 = bits per cell in erase region
bit 4 = internal EDAC used (1=yes, 0=no)
bits 5–7 = reserve for future use
(P+41)h (P+41)h Partition 1 (erase block Type 2) page mode and synchronous mode capabilities
defined in Table 10.
1
6
14B:
14B:
bit 0 = page-mode host reads permitted (1=yes, 0=no)
bit 1 = synchronous host reads permitted (1=yes, 0=no)
bit 2 = synchronous host writes permitted (1=yes, 0=no)
bits 3–7 = reserved for future use
Partition Region 1 (Erase Block Type 2) Programming Region Information
(P+42)h (P+42)h
(P+43)h (P+43)h
(P+44)h (P+44)h
(P+45)h (P+45)h
(P+46)h (P+46)h
(P+47)h (P+47)h
14C:
14D:
14E:
14F:
150:
151:
bits 0–7 = x, 2^x = Programming Region aligned size (bytes)
bits 8–14 = Reserved; bit 15 = Legacy flash operation (ignore 0:7)
bits 16–23 = y = Control Mode valid size in bytes
14C:
14D:
14E:
14F:
150:
151:
bits 24-31 = Reserved
bits 32-39 = z = Control Mode invalid size in bytes
bits 40-46 = Reserved; bit 47 = Legacy flash operation (ignore 23:16 & 39:32)
Datasheet
76
August 2008
306666-12
P30
Table 49: Partition and Erase Block Region Information
Address
64-Mbit
128-Mbit
256-Mbit
–B
–T
–B
–T
–B
–T
12D:
12E:
12F:
130:
131:
132:
133:
134:
135:
136:
137:
138:
139:
13A:
13B:
13C:
13D:
13E:
13F:
140:
141:
142:
143:
144:
145:
146:
147:
148:
149:
14A:
14B:
14C:
14D:
14E:
14F:
150:
151:
--01
--24
--00
--01
--00
--11
--00
--00
--02
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--3E
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--01
--24
--00
--01
--00
--11
--00
--00
--02
--3E
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--01
--24
--00
--01
--00
--11
--00
--00
--02
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--7E
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--01
--24
--00
--01
--00
--11
--00
--00
--02
--7E
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--01
--24
--00
--01
--00
--11
--00
--00
--02
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--FE
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--01
--24
--00
--01
--00
--11
--00
--00
--02
--FE
--00
--00
--02
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
--03
--00
--80
--00
--64
--00
--02
--03
--00
--80
--00
--00
--00
--80
August 2008
Order Number: 306666-12
Datasheet
77
P30
Table 50: CFI Link Information
Offset(1)
Length
Hex
Description
P = 10Ah
(Optional flash features and commands)
CFI Link Field bit definitions
Add.
152:
153:
154:
155:
Code
Value
(P+48)h
(P+49)h
(P+4A)h
(P+4B)h
4
Bits 0–9 = Address offset (within 32Mbit segment) of referenced CFI table
Bits 10–27 = nth 32Mbit segment of referenced CFI table
Bits 28–30 = Memory Type
Bit 31 = Another CFI Link field immediately follows
CFI Link Field Quantity Subfield definitions
Bits 0–3 = Quantity field (n such that n+1 equals quantity)
Bit 4 = Table & Die relative location
See table below
See table below
(P+4C)h
1
156:
Bit 5 = Link Field & Table relative location
Bits 6–7 = Reserved
Discrete
512-Mbit
Address
–B
–-
–T
–-
–B
–T
die 1 (B)
--10
--20
--00
--00
die 2 (T)
die 1 (T)
--10
--20
--00
--00
die 2 (B)
--FF
--FF
--FF
--FF
152:
153:
154:
155:
156:
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--FF
--10
--10
--FF
Datasheet
78
August 2008
306666-12
P30
A.2
Flowcharts
Figure 34: Word Program Flowchart
WORD PROGRAM PROCEDURE
Bus
Operation
Start
Command
Comments
Program Data = 0x40
Setup Addr = Location to program
Write
Write
Read
Write 0x40,
Word Address
(Setup)
Data = Data to program
Data
Addr = Location to program
Write Data,
Word Address
(Confirm)
None
None
Status register data
Program
Suspend
Loop
Read Status
Register
Check SR[7]
1 = WSM Ready
0 = WSM Busy
Idle
No
Suspend?
Yes
0
SR[7] =
1
Repeat for subsequent Word Program operations.
Full Status Register check can be done after each program, or
after a sequence of program operations.
Full Status
Check
(if desired)
Write 0xFF after the last operation to set to the Read Array
state.
Program
Complete
FULL STATUS CHECK PROCEDURE
Read Status
Register
Bus
Command
Operation
Comments
Check SR[3]:
1 = VPP Error
Idle
Idle
None
None
1
1
1
VPP Range
Error
SR[3] =
0
Check SR[4]:
1 = Data Program Error
Program
Error
Check SR[1]:
1 = Block locked; operation aborted
SR[4] =
0
Idle
None
If an error is detected, clear the Status Register before
continuing operations - only the Clear Staus Register
command clears the Status Register error bits.
Device
Protect Error
SR[1] =
0
Program
Successful
August 2008
Order Number: 306666-12
Datasheet
79
P30
Figure 35: Program Suspend/Resume Flowchart
PROGRAM SUSPEND / RESUME PROCEDURE
Bus
Operation
Start
Command
Comments
Read Status
Write 70h
Read
Data = 70h
Write
Write
Status Addr = Block to suspend(BA)
Program Data = B0h
Suspend Addr = X
Program Suspend
Write B0h
Any Address
Status register data
Initiate a read cycle to update Status
register
Addr = Suspended block (BA)
Read
Read Status
Register
Check SR.7
Standby
Standby
1 = WSM ready
0 = WSM busy
0
0
SR.7 =
1
Check SR.2
1 = Program suspended
0 = Program completed
Program
Completed
SR.2 =
1
Read
Array
Data = FFh
Addr = Block address to read (BA)
Write
Read
Write
Read Array
Write FFh
Read array data from block other than
the one being programmed
Read Array
Data
Program Data = D0h
Resume Addr = Suspended block (BA)
Done
No
Reading
Yes
Program Resume
Read Array
Write FFh
Write D0h
Any Address
Program
Resumed
Read Array
Data
PGM_SUS.WMF
Datasheet
80
August 2008
306666-12
P30
Figure 36: Buffer Program Flowchart
Bus
Operation
Command
Comments
Data = E8H
Write to
Buffer
Write
Read
Addr = Block Address
Start
SR.7 = Valid
Addr = Block Address
Device
Check SR.7
1 = Device WSM is Busy
0 = Device WSM is Ready
Use Single Word
Supports Buffer
Standby
No
Programming
Writes?
Yes
Data = N-1 = Word Count
N = 0 corresponds to count = 1
Addr = Block Address
Write
(Notes1, 2)
Set Timeout or
Loop Counter
Write
(Notes3, 4)
Data = Write Buffer Data
Addr = Start Address
Get Next
Target Address
Write
(Notes5, 6)
Data = Write Buffer Data
Addr = Block Address
Issue Write to Buffer
Command E8h and
Block Address
Program
Confirm
Data = D0H
Addr = Block Address
Write
Read
Status register Data
CE# and OE# low updates SR
Addr = Block Address
Read Status Register
(at Block Address)
Check SR.7
1 = WSM Ready
0 = WSM Busy
No
Standby
Timeout
or Count
Expired?
0 = No
Is WSM Ready?
SR.7 =
1. Word count values on DQ0-DQ7 are loaded into the Count
register. Count ranges for this device are N = 0000h to 0001Fh.
2. The device outputs the status register when read.
3. Write Buffer contents will be programmed at the device start
address or destination flash address.
Yes
1 = Yes
Write Word Count,
Block Address
4. Align the start address on a Write Buffer boundary for
maximum programming performance(i.e., A4–A0 of the start
address = 0).
Write Buffer Data,
Start Address
5. The device aborts the Buffered Program command if the
current address is outside the original block address.
6. The Status register indicates an "improper command
sequence" if the Buffered Program command is aborted. Follow
this with a Clear Status Register command.
X = X + 1
Write Buffer Data,
Block Address
X = 0
Full status check can be done after all erase and write
sequences complete. Write FFh after the last operation to reset
the device to read array mode.
No
No
Abort Bufferred
Program?
X = N?
Yes
Yes
Write Confirm D0h
and Block Address
Write to another
Block Address
Buffered Program
Aborted
Read Status Register
No
Suspend
Program
Loop
Yes
0
Suspend
Program
SR.7 =?
Full Status
Check if Desired
1
Yes
Another Buffered
Programming?
No
Program Complete
August 2008
Order Number: 306666-12
Datasheet
81
P30
Figure 37: BEFP Flowchart
BUFFERED ENHANCED FACTORY PROGRAMMING (BEFP) PROCEDURE
Setup Phase
Program & Verify Phase
Exit Phase
Read
Status Reg.
Read
Status Reg.
Start
VPP applied
Block Unlocked
No (SR[7]=0)
BEFP
Exited?
No (SR[0]=1)
Data Stream
Ready?
Yes (SR[0]=0)
Yes (SR[7]=1)
Write 80h @
1st Word Address
Initialize Count:
X = 0
Full Status Check
Procedure
Write D0h @
1st Word Address
Write Data @ 1st
Word Address
Program
Complete
BEFP Setup delay
Increment Count:
X = X+1
Read
Status Reg.
N
Check
X = 32?
Yes (SR[7]=0)
Y
BEFP Setup
Done?
Read
No (SR[7]=1)
Status Reg.
No (SR[0]=1)
Check VPP, Lock
errors (SR[3,1])
Program
Done?
Yes (SR[0]=0)
Exit
N
Last
Data?
Y
Write 0xFFFF,
Address Not within
Current Block
BEFP Setup
BEFP Program & Verify
BEFP Exit
Operation Comments
Bus
State
Bus
State
Bus
State
Operation
Comments
Operation
Comments
Unlock
Block
Status
Register
Data = Status Register Data
Address = 1st Word Addr.
Status
Register
Data = Status Register Data
Address = 1st Word Addr.
Read
Write
VPPH applied to VPP
Read
Write
(Note 1)
BEFP
Setup
Data = 0x80 @ 1st Word
Address
Data = 0x80 @ 1st Word
Address1
Check SR[0]:
0 = Ready for Data
1 = Not Ready for Data
Check
Exit
Status
Check SR[7]:
0 = Exit Not Completed
1 = Exit Completed
Data Stream
Ready?
Standby
Standby
Standby
BEFP
Confirm
Write
Read
Initialize
Count
Repeat for subsequent blocks ;
X = 0
Status
Register
Data = Status Register Data
Address = 1st Word Addr.
After BEFP exit, a full Status Register check can
determine if any program error occurred;
Write
(note 2)
Load
Buffer
Data = Data to Program
Address = 1st Word Addr.
BEFP
Setup
Done?
Check SR[7]:
0 = BEFP Ready
1 = BEFP Not Ready
Standby
Standby
Increment
Count
See full Status Register check procedure in the
Word Program flowchart.
Standby
Standby
Read
X = X+1
X = 32?
Yes = Read SR[0]
No = Load Next Data Word
Error
Condition
Check
If SR[7] is set, check:
SR[3] set = VPP Error
SR[1] set = Locked Block
Buffer
Full?
Write 0xFF to enter Read Array state.
Status
Register
Data = Status Reg. Data
Address = 1st Word Addr.
Check SR[0]:
0 = Program Done
1 = Program in Progress
Program
Done?
Standby
Last
Data?
No = Fill buffer again
Yes = Exit
Standby
Write
Exit Prog & Data = 0xFFFF @ address
Verify Phase not in current block
NOTES:
1. First-word address to be programmed within the target block must be aligned on a write -buffer boundary.
2. Write-buffer contents are programmed sequentially to the flash array starting at the first word address (WSM internally increments addressing).
Datasheet
82
August 2008
306666-12
P30
Figure 38: Block Erase Flowchart
BLOCK ERASE PROCEDURE
Bus
Operation
Start
Command
Comments
Block
Erase
Setup
Data = 0x20
Addr = Block to be erased (BA)
Write
Write
Read
Write 0x20,
Block Address
(Block Erase)
Erase Data = 0xD0
Confirm Addr = Block to be erased (BA)
Write 0xD0,
Block Address
(Erase Confirm)
None
None
Status Register data.
Suspend
Erase
Loop
Read Status
Register
Check SR[7]:
1 = WSM ready
0 = WSM busy
Idle
No
Suspend
Erase
0
Yes
SR[7] =
1
Repeat for subsequent block erasures.
Full Status register check can be done after each block erase
or after a sequence of block erasures.
Full Erase
Status Check
(if desired)
Write 0xFF after the last operation to enter read array mode.
Block Erase
Complete
FULL ERASE STATUS CHECK PROCEDURE
Read Status
Register
Bus
Command
Operation
Comments
Check SR[3]:
1 = VPP Range Error
Idle
Idle
Idle
None
None
None
1
VPP Range
Error
SR[3] =
0
Check SR[4,5]:
Both 1 = Command Sequence Error
1,1
1
Command
Sequence Error
Check SR[5]:
1 = Block Erase Error
SR[4,5] =
0
Check SR[1]:
1 = Attempted erase of locked block;
erase aborted.
Block Erase
Error
Idle
None
SR[5] =
0
Only the Clear Status Register command clears SR[1, 3, 4, 5].
If an error is detected, clear the Status register before
attempting an erase retry or other error recovery.
1
Block Locked
Error
SR[1] =
0
Block Erase
Successful
August 2008
Order Number: 306666-12
Datasheet
83
P30
Figure 39: Erase Suspend/Resume Flowchart
ERASE SUSPEND / RESUME PROCEDURE
Bus
Operation
Start
Command
Comments
Read Status
Write 70h
Any Address
Read
Data = 70h
Write
Write
Status Addr = Any device address
Data = B0h
Addr = Same partition address as
Erase
Suspend
above
Erase Suspend
Write B0h
Any Address
Status register data. Toggle CE# or
OE# to update Status register
Addr =X
Read
Read Status
Register
Check SR.7
Standby
1 = WSM ready
0 = WSM busy
0
0
SR.7 =
1
Check SR.6
1 = Erase suspended
0 = Erase completed
Standby
Write
Erase
Completed
SR.6 =
1
Read Array Data = FFh or 40h
or Program Addr = Block to program or read
Read or
Write
Read array or program data from/to
block other than the one being erased
Read
Program
Read or
Program ?
Read Array
Data
Program
Loop
Program Data = D0h
Resume Addr = Any address
No
Write
Done?
Yes
Erase Resume
Read Array
Write D0h
Write FFh
Any Address
Any Addres
Erase
Resumed
Read Array
Data
Read Status
Write 70h
Any Address
ERAS_SUS.WMF
Datasheet
84
August 2008
306666-12
P30
Figure 40: Block Lock Operations Flowchart
LOCKING OPERATIONS PROCEDURE
Bus
Operation
Start
Command
Comments
Lock Setup
Write 60h
Block Address
Lock
Setup
Data = 60h
Addr = Block to lock/unlock/lock-down (BA)
Write
Write
Lock,
Unlock, or
Lockdown
Data = 01h (Lock block)
D0h (Unlock block)
Lock Confirm
Write 01,D0,2Fh
Block Address
2Fh (Lockdown block)
Confirm Addr = Block to lock/unlock/lock-down (BA)
Read ID Plane
Write 90h
Write
(Optional)
Read ID Data = 90h
Plane
Addr = Block address offset+2 (BA+2)
Read
(Optional)
Block Lock Block Lock status data
Status Addr = Block address offset+2 (BA+2)
Read Block Lock
Status
Confirm locking change on DQ , DQ0.
(See Block Locking State Transitions Table
for valid combinations.)
1
Standby
(Optional)
Locking
No
Change?
Yes
Read
Array
Data = FFh
Addr = Block address (BA)
Write
Read Array
Write FFh
Any Address
Lock Change
Complete
LOCK_OP.WMF
August 2008
Order Number: 306666-12
Datasheet
85
P30
Figure 41: Protection Register Programming Flowchart
PROTECTION REGISTER PROGRAMMING PROCEDURE
Bus
Operation
Start
Command
Comments
Program Data = 0xC0
PR Setup Addr = First Location to Program
Write
Write 0xC0,
PR Address
(Program Setup)
(Confirm Data)
Protection Data = Data to Program
Program Addr = Location to Program
Write
Read
Write PR
Address & Data
None
None
Status Register Data.
Read Status
Register
Check SR[7]:
1 = WSM Ready
0 = WSM Busy
Idle
Program Protection Register operation addresses must be
within the Protection Register address space. Addresses
outside this space will return an error.
0
SR[7] =
1
Repeat for subsequent programming operations.
Full Status
Check
(if desired)
Full Status Register check can be done after each program, or
after a sequence of program operations.
Write 0xFF after the last operation to set Read Array state.
Program
Complete
FULL STATUS CHECK PROCEDURE
Read Status
Register Data
Bus
Operation
Command
Comments
Check SR[3]:
1 =VPP Range Error
Idle
Idle
Idle
None
1
1
1
SR[3] =
0
VPP Range Error
Check SR[4]:
1 =Programming Error
None
None
Check SR[1]:
1 =Block locked; operation aborted
SR[4] =
0
Program Error
Only the Clear Staus Register command clears SR[1, 3, 4].
If an error is detected, clear the Status register before
attempting a program retry or other error recovery.
Register Locked;
Program Aborted
SR[1] =
0
Program
Successful
A.3
Write State Machine
Figure 42 through Figure 47 show the command state transitions (Next State Table)
based on incoming commands. Only one partition can be actively programming or
erasing at a time. Each partition stays in its last read state (Read Array, Read Device
ID, Read CFI or Read Status Register) until a new command changes it. The next WSM
state does not depend on the partition’s output state.
Datasheet
86
August 2008
306666-12
P30
Figure 42: Write State Machine—Next State Table (Sheet 1 of 6)
Command Input to Chip and resulting Chip Next State
BE Confirm,
Buffered
Enhanced
P/E
Resume,
ULB,
Clear
Status
Register (5)
Lock, Unlock,
Lock-down,
CR setup (4)
Buffered
Program
(BP)
BP / Prg /
Erase
Suspend
Read
Word
Program (3,4)
Erase
Setup (3,4)
Read
Status
Read
ID/Query
(2)
Current Chip
State (7)
Factory Pgm
Array
Setup (3, 4)
Confirm (8)
(FFH)
(10H/40H)
(E8H)
(20H)
(80H)
(D0H)
(B0H)
(70H)
(50H)
(90H, 98H)
(60H)
Program
Setup
Erase
Setup
Lock/CR
Setup
Ready
Ready
Ready
BP Setup
BEFP Setup
Ready
(Unlock
Block)
Lock/CR Setup
Ready (Lock Error)
Ready (Lock Error)
Setup
OTP
Busy
OTP Busy
Word Program Busy
Word
Setup
Program Busy
Word Program Busy
Busy
Program
Suspend
Word
Program
Word
Program
Busy
Word Program Suspend
Word Program Suspend
Suspend
BP Load 1
BP Load 2
Setup
BP Load 1
BP Confirm if Data load into Program Buffer is complete; Else BP Load 2
BP Load 2
BP
BP
Confirm
Ready (Error)
Ready (Error)
BP Busy
BP Busy
BP Busy
BP Suspend
Ready (Error)
Erase Busy
BP Busy
BP Suspend
BP
Suspend
BP Suspend
Ready (Error)
BP Busy
Setup
Erase Busy
Erase
Suspend
Erase Busy
Busy
Erase
Word
Program
Setup in
Erase
Lock/CR
Setup in
Erase
BP Setup in
Erase
Suspend
Erase
Suspend
Erase Suspend
Erase Suspend
Suspend
Erase Busy
Suspend
Suspend
August 2008
Order Number: 306666-12
Datasheet
87
P30
Figure 43: Write State Machine—Next State Table (Sheet 2 of 6)
Chip
Command Input to Chip and resulting
Next State
BE Confirm,
Buffered
Enhanced
Factory Pgm
Setup (3, 4)
P/E
Resume,
ULB,
Confirm (8)
Clear
Status
Register (5)
Lock, Unlock,
Lock-down,
CR setup (4)
Buffered
Program
(BP)
BP / Prg /
Erase
Suspend
Read
Word
Program (3,4)
Erase
Setup (3,4)
Read
Status
Read
ID/Query
(2)
Current Chip
State (7)
Array
(FFH)
(10H/40H)
(E8H)
(20H)
(80H)
(D0H)
(B0H)
(70H)
(50H)
(90H, 98H)
(60H)
Word Program Busy in Erase Suspend
Setup
Word
Program
Word Program Busy in Erase Suspend
Word Program Busy in Erase Suspend Busy
Word Program Suspend in Erase Suspend
Busy
Suspend in
Erase
Suspend
Word
Program in
Erase
Word
Program
Busy in
Erase
Suspend
Word Program Suspend in Erase Suspend
Suspend
Suspend
BP Load 1
BP Load 2
Setup
BP Load 1
BP Confirm if Data load into Program Buffer is complete; Else BP Load 2
BP Load 2
BP Busy in
Erase
Suspend
BP in Erase
Suspend
BP
Confirm
Erase Suspend (Error)
Ready (Error in Erase Suspend)
BP Suspend
in Erase
BP Busy in Erase Suspend
BP Busy in Erase Suspend
BP Busy
Suspend
BP Busy in
Erase
Suspend
BP
Suspend
BP Suspend in Erase Suspend
BP Suspend in Erase Suspend
Erase
Suspend
(Unlock
Block)
Lock/CR Setup in Erase
Suspend
Erase Suspend (Lock Error)
Ready (Error)
Erase Suspend (Lock Error [Botch])
Ready (Error)
BEFP
Loading
Buffered
Setup
Enhanced
Factory
Data (X=32)
Program
BEFP
Mode
BEFP Program and Verify Busy (if Block Address given matches address given on BEFP Setup command). Commands treated as data. (7)
Busy
Datasheet
88
August 2008
306666-12
P30
Figure 44: Write State Machine—Next State Table (Sheet 3 of 6)
Chip
Command Input to Chip and resulting
Next State
Lock
Block
Confirm (8) Confirm
Lock-Down
OTP
Setup (4)
Write RCR
Block Address
Illegal Cmds or
BEFP Data (1)
Block
WSM
Operation
Completes
Current Chip
State (7)
(8)
9
Confirm
(?WA0)
(8)
(C0H)
(01H)
(2FH)
(03H)
(XXXXH)
(all other codes)
OTP
Setup
Ready
Ready
Ready
(Lock
Error)
Ready
(Lock
Block)
Ready
(Lock Down
Blk)
Ready
(Set CR)
N/A
Lock/CR Setup
Ready (Lock Error)
Setup
OTP Busy
OTP
Busy
Ready
N/A
Word Program Busy
Word Program Busy
Setup
Ready
Busy
Word
Program
Word Program Suspend
BP Load 1
Suspend
Setup
BP Load 2
Ready (BP Load 2 BP Load 2
BP Load 1
BP Confirm if
Data load into
Program Buffer is
complete; ELSE
BP Load 2
N/A
BP Confirm if Data load into Program Buffer is
complete; ELSE BP load 2
BP Load 2
Ready
BP
Ready (Error)
(Proceed if
unlocked or lock
error)
BP
Confirm
Ready (Error)
Ready (Error)
BP Busy
BP Busy
BP Suspend
Ready (Error)
Erase Busy
Ready
N/A
BP
Suspend
Setup
Busy
Ready
Erase
Suspend
Erase Suspend
N/A
August 2008
Order Number: 306666-12
Datasheet
89
P30
Figure 45: Write State Machine—Next State Table (Sheet 4 of 6)
Chip
Command Input to Chip and resulting
Next State
Lock
Block
Confirm (8) Confirm
Lock-Down
OTP
Setup (4)
Write RCR
Block Address
Illegal Cmds or
BEFP Data (1)
Block
WSM
Operation
Completes
(8)
9
Current Chip
State (7)
Confirm
(?WA0)
(8)
(C0H)
(01H)
(2FH)
(03H)
(XXXXH)
(all other codes)
Word Program Busy in Erase Suspend
Setup
NA
Word Program Busy in Erase Suspend Busy
Busy
Erase Suspend
Word
Program in
Erase
Suspend
Word Program Suspend in Erase Suspend
BP Load 1
Suspend
N/A
Setup
BP Load 2
Ready (BP Load 2 BP Load 2
BP Load 1
BP Confirm if
Data load into
Program Buffer is
complete; Else
BP Load 2
BP Confirm if Data load into Program Buffer is
complete; Else BP Load 2
N/A
Ready
BP Load 2
BP in Erase
Suspend
BP
Ready (Error)
(Proceed if
unlocked or lock
error)
Ready (Error in Erase Suspend)
Ready (Error)
Confirm
BP Busy in Erase Suspend
Erase Suspend
BP Busy
BP
Suspend
BP Suspend in Erase Suspend
Erase
Suspend Suspend
(Lock
Error)
Erase
Erase
Erase
Suspend
Lock/CR Setup in Erase
Suspend
Erase Suspend (Lock Error)
Suspend
(Set CR)
N/A
(Lock
Block)
(Lock Down
Block)
Ready (BEFP
Ready (Error)
Loading Data)
Ready (Error)
Buffered
Enhanced
Factory
Program
Mode
Setup
BEFP Program and Verify Busy (if Block Address
given matches address given on BEFP Setup
command). Commands treated as data. (7)
BEFP
Busy
Ready
Ready
BEFP Busy
Datasheet
90
August 2008
306666-12
P30
Figure 46: Write State Machine—Next State Table (Sheet 5 of 6)
Output Next State Table
Output
Command Input to Chip and resulting
Mux Next State
BE Confirm,
Buffered
P/E
Clear
Status
Register (5)
Lock, Unlock,
Lock-down,
Word
Program
Setup (3,4)
Program/
Erase
Suspend
Read
Erase
Enhanced
Factory Pgm
Setup (3, 4)
Read
Status
Read
ID/Query
Resume,
BP Setup
(E8H)
(2)
Array
Setup (3,4)
Current chip state
CR setup (4)
ULB Confirm
(8)
(FFH)
(10H/40H)
(20H)
(30H)
(D0H)
(B0H)
(70H)
(50H)
(90H, 98H)
(60H)
BEFP Setup,
BEFP Pgm & Verify
Busy,
Erase Setup,
OTP Setup,
BP: Setup, Load 1,
Load 2, Confirm,
Word Pgm Setup,
Word Pgm Setup in
Erase Susp,
Status Read
BP Setup, Load1,
Load 2, Confirm in
Erase Suspend
Lock/CR Setup,
Lock/CR Setup in
Erase Susp
Status Read
Status
Read
OTP Busy
Ready,
Erase Suspend,
BP Suspend
BP Busy,
Word Program
Busy,
Erase Busy,
BP Busy
Output mux
does not
change.
Read Array
Status Read
Output does not change.
Status Read
Status Read
ID Read
BP Busy in Erase
Suspend
Word Pgm
Suspend,
Word Pgm Busy in
Erase Suspend,
Pgm Suspend In
Erase Suspend
August 2008
Order Number: 306666-12
Datasheet
91
P30
Figure 47: Write State Machine—Next State Table (Sheet 6 of 6)
Output Next State Table
Output
Command Input to Chip and resulting
Mux Next State
Lock
Block
Confirm (8) Confirm
Lock-Down
OTP
Setup (4)
Write CR
Illegal Cmds or
BEFP Data (1)
Block Address
(?WA0)
Block
WSM
(8)
Confirm
(8)
Operation
Completes
Current chip state
(C0H)
(01H)
(2FH)
(03H)
(FFFFH)
(all other codes)
BEFP Setup,
BEFP Pgm & Verify
Busy,
Erase Setup,
OTP Setup,
BP: Setup, Load 1,
Load 2, Confirm,
Word Pgm Setup,
Word Pgm Setup in
Erase Susp,
Status Read
BP Setup, Load1,
Load 2, Confirm in
Erase Suspend
Lock/CR Setup,
Lock/CR Setup in
Erase Susp
Array
Read
Status Read
Status Read
Output does
not change.
OTP Busy
Ready,
Erase Suspend,
BP Suspend
BP Busy,
Word Program
Busy,
Erase Busy,
BP Busy
Status
Read
Output does not
change.
Output does not change.
Array Read
BP Busy in Erase
Suspend
Word Pgm
Suspend,
Word Pgm Busy in
Erase Suspend,
Pgm Suspend In
Erase Suspend
Notes:
1.
"Illegal commands" include commands outside of the allowed command set (allowed commands: 40H [pgm], 20H [erase],
etc.)
2.
3.
4.
If a "Read Array" is attempted from a busy partition, the result will be invalid data. The ID and CFI data are located at
different locations in the address map.
1st and 2nd cycles of "2 cycles write commands" must be given to the same partition address, or unexpected results will
occur.
To protect memory contents against erroneous command sequences, there are specific instances in a multi-cycle
command sequence in which the second cycle will be ignored. For example, when the device is program suspended and an
erase setup command (0x20) is given followed by a confirm/resume command (0xD0), the second command will be
ignored because it is unclear whether the user intends to erase the block or resume the program operation.
The Clear Status command only clears the error bits in the status register if the device is not in the following modes: WSM
running (Pgm Busy, Erase Busy, Pgm Busy In Erase Suspend, OTP Busy, BEFP modes).
BEFP writes are only allowed when the status register bit #0 = 0, or else the data is ignored.
5.
6.
Datasheet
92
August 2008
306666-12
P30
7.
The "current state" is that of the "chip" and not of the "partition"; Each partition "remembers" which output (Array, ID/CFI
or Status) it was last pointed to on the last instruction to the "chip", but the next state of the chip does not depend on
where the partition's output mux is presently pointing to.
8.
9.
Confirm commands (Lock Block, Unlock Block, Lock-Down Block, Configuration Register) perform the operation and then
move to the Ready State.
WA0 refers to the block address latched during the first write cycle of the current operation.
August 2008
Order Number: 306666-12
Datasheet
93
P30
Appendix B Conventions - Additional Information
B.1
Conventions
VCC:
Signal or voltage connection
VCC
0x:
0b:
:
Signal or voltage level
Hexadecimal number prefix
Binary number prefix
SR[4]:
A[15:0]:
A5:
Denotes an individual register bit.
Denotes a group of similarly named signals, such as address or data bus.
Denotes one element of a signal group membership, such as an individual address bit.
Bit:
Binary unit
Byte:
Eight bits
Word:
Kbit:
Two bytes, or sixteen bits
1024 bits
KByte:
KWord:
Mbit:
1024 bytes
1024 words
1,048,576 bits
1,048,576 bytes
1,048,576 words
MByte:
MWord:
B.2
Acronyms
BEFP:
CUI:
MLC:
OTP:
PLR:
PR:
Buffer Enhanced Factory Programming
Command User Interface
Multi-Level Cell
One-Time Programmable
Protection Lock Register
Protection Register
RCR:
RFU:
SR:
Read Configuration Register
Reserved for Future Use
Status Register
WSM:
Write State Machine
Datasheet
94
August 2008
306666-12
P30
B.3
Nomenclature
A group of bits, bytes, or words within the flash memory array that erase
simultaneously. The P30 has two block sizes: 32 KByte and 128 KByte.
Block :
An array block that is usually used to store code and/or data. Main blocks are larger
than parameter blocks.
Main block :
Parameter block :
An array block that may be used to store frequently changing data or small system
parameters that traditionally would be stored in EEPROM.
A device with its parameter blocks located at the highest physical address of its
memory map.
Top parameter device :
A device with its parameter blocks located at the lowest physical address of its
memory map.
Bottom parameter device :
B.4
Additional Documentation
Order/Document
Document/Tool
Number
309045
308291
300783
290667
P30 Family Specification Update
Schematic Review Checklist for Numonyx™ StrataFlash® Embedded Memory (P30)
Using Numonyx™ Flash Memory: Asynchronous Page Mode and Synchronous Burst Mode
Numonyx™ StrataFlash® Memory (J3) Datasheet
Migration Guide for Numonyx™ StrataFlash® Memory (J3) to Numonyx™ StrataFlash® Embedded
Memory (P30/P33) Application Note 812
306667
Numonyx™ StrataFlash® Memory (P30) to Numonyx™ StrataFlash® Embedded Memory (P33)
Conversion Guide Application Note 867
314750
290737
306669
Numonyx™ StrataFlash® Synchronous Memory (K3/K18) Datasheet
Migration Guide for Numonyx™ StrataFlash® Synchronous Memory (K3/K18) to Numonyx™
StrataFlash® Embedded Memory (P30) Application Note 825
290701
290702
252802
298161
253418
296514
297833
298136
Numonyx™ Wireless Flash Memory (W18) Datasheet
Numonyx™ Wireless Flash Memory (W30) Datasheet
Numonyx™ Flash Memory Design for a Stacked Chip Scale Package (SCSP)
Numonyx™ Flash Memory Chip Scale Package User’s Guide
Numonyx™ Wireless Communications and Computing Package User's Guide
Numonyx™ Small Outline Package Guide
Numonyx™ Flash Data Integrator (Numonyx™ FDI) User Guide
Numonyx™ Persistent Storage Manager (Numonyx™ PSM) User Guide
Migration Guide for Spansion* S29GLxxxN to Numonyx™ StrataFlash® Embedded Memory (P30/P33)
Application Note 813
306668
Note: Contact your local Numonyx or distribution sales office or visit Numonyx’s World Wide Web home page at http://
www.numonyx.com for technical documentation, tools, or the most current information on Numonyx™ Flash Memory.
August 2008
Order Number: 306666-12
Datasheet
95
P30
Appendix C Revision History
Revision Date
Revision
Description
April 2005
-001
Initial Release
Revised discrete memory maps in Section 1.4, “Memory Maps” on
page 6
Added memory maps for 512-Mbit top parameter devices in Section 1.4,
“Memory Maps” on page 6
Fixed size of Programming Region for 256-Mbit to be 8-Mbit in Section 1.4,
“Memory Maps” on page 6 and Section 8.0, “Program Operation”
on page 28
August 2005
-002
Removed power supply sequencing requirement in Section 12.1, “Power-Up
and Power-Down” on page 49
Updated conditions for Table 29, “Capacitance” on page 55
Updated CFI table in Appendix A, “Common Flash Interface Tables”
Added note to Table 14, “Device ID codes” on page 27 for stacked
Device ID codes
September 2005
-003
Synchronous burst read operation is currently not supported for the TSOP package
Updated 512-Mbit Easy BGA Ball Height (symbol A1) in Figure 2, “Easy BGA
Mechanical Specifications” on page 10
November 2005
February 2006
-004
-005
Updated read access speed for 265M TSOP package
Removed all references to 1 Gigabit.
•
•
•
Added 52 MHz capabilities,
Added TSOP Package information for 512 Mb throughout the document,
Added Section 1.3, “Virtual Chip Enable Description” on
page 6,
•
•
•
•
Modified figures in Section 4.1, “Dual-Die Configurations” on
page 20,
April 2006
-006
Modified Table 5, “512-Mbit Top and Bottom Parameter
Memory Map (Easy BGA and QUAD+ SCSP)” on page 8,
Modified Notes 5 & 6 to Reset Specifications table in Section 12.2,
“Reset Specifications” on page 49,
Added additional note on 512 Mb capability in Table 17, “Selectable
OTP Block Mapping” on page 38.
•
Updated the following tables to 52 MHz: Table 30, “AC Read
Specifications for 64/128- Mbit Densities” on page 55 and
Table 31, “AC Read Specifications for 256/512-Mbit
Densities” on page 56.
May 2006
May-2006
-007
-008
•
Added notes 1, 2, and 3 to Table 29, “Capacitance” on page 55.
•
•
•
•
•
•
Correct typos and add clarifications
Enabled specific burst operation on TSOP packages.
Updated device commands table.
Updaed description on synchronous burst operation.
Added EOWL description.
June - 2007
-009
Updated flowcharts
•
•
Updated for 65nm lithography
Added W602 - Erase to Suspend
November 2007
November 2007
-010
11
•
•
Applied Numonyx branding.
Corrected single word (65 nm) program time from 125 (typ) and 150 (max) to
150 (typ) and 456 (max) in Table 34, “Program and Erase
Specifications” on page 66.
August 2008
12
Datasheet
96
August 2008
306666-12
相关型号:
PC28F640P33BF60D
Numonyx® P33-65nm Flash Memory 128-Mbit, 64-Mbit Single Bit per Cell (SBC)
NUMONYX
©2020 ICPDF网 联系我们和版权申明