FXPQ3115BVT1 [NXP]

I2C precision pressure sensor with altimetry;
FXPQ3115BVT1
型号: FXPQ3115BVT1
厂家: NXP    NXP
描述:

I2C precision pressure sensor with altimetry

文件: 总14页 (文件大小:523K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
Rev. 1 — 9 October 2017  
Short data sheet: technical data  
1 General description  
The FXPQ3115BV is a compact, piezoresistive, absolute pressure sensor with an I2C  
digital interface. FXPQ3115BV has a wide operating range of 20 kPa to 110 kPa. This  
sensor is ideal for inhalers, continuous positive airway pressure (CPAP) masks or  
other medical devices coming in contact with a patient's airway. The MEMS and ASIC  
die are coated with a biomedically-approved gel. The gel is a nontoxic, nonallergenic  
elastomer which meets all United States Pharmacopeia (USP) biological testing class  
VI requirements. The gel properties allow uniform pressure transmission to the MEMS  
diaphragm.  
A high resolution ADC provides fully compensated and digitized outputs for pressure in  
Pascals and temperature in °C. The compensated output is available as either barometric  
pressure in Pascals or as an altitude in meters. The internal processing in FXPQ3115BV  
removes compensation and unit conversion load from the system MCU, simplifying  
system design.  
FXPQ3115BV's advanced ASIC has multiple user programmable modes such as power  
saving, interrupt and autonomous data acquisition modes, including programmed  
acquisition cycle timing, and poll-only modes. Typical active supply current is 40 μA per  
measurement-second.  
2 Features and benefits  
Operating range: 20 kPa to 110 kPa absolute pressure  
Calibrated range: 50 kPa to 110 kPa absolute pressure  
Calibrated temperature output: −40 °C to 85 °C  
I2C digital output interface  
Fully compensated internally  
Precision ADC resulting in 1.5 Pa of effective resolution  
Direct reading  
Programmable interrupts  
Autonomous data acquisition  
Embedded 32-sample FIFO  
Data logging up to 12 days using the FIFO  
One-second to nine-hour data acquisition rate  
1.95 V to 3.6 V supply voltage, internally regulated  
1.6 V to 3.6 V digital interface supply voltage  
Operating temperature from −40 °C to +85 °C  
Pressure: 20-bit measurement (Pascals)  
20 to 110 kPa  
Temperature: 12-bit measurement (°C)  
–40 °C to 85 °C  
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
3 Applications  
Inhalers/nebulizers  
Medical tablets  
Health activity monitors  
Oxygen concentrators  
CPAP machine and mask  
Spyrometry  
4 Ordering information  
Table 1.ꢀOrdering information  
Device number Shipping  
Package  
Number of ports  
Pressure Type  
Digital  
interface  
None Single Dual Gauge Differential Absolute  
FXPQ3115BV  
Tray  
98ASA002260D  
FXPQ3115BVT1 Tape and reel 98ASA002260D  
5 Block diagram  
Figure 1.ꢀBlock diagram  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
2 / 14  
 
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
6 Pinning information  
6.1 Pinning  
FXPQ3115BV  
VDD  
1
2
3
4
8
7
6
5
SCL  
SDL  
CAP  
GND  
VDDIO  
INT1  
INT2  
Transparent top view  
Figure 2.ꢀ8-pin LGA pinout  
6.2 Pin description  
Table 2.ꢀPin description  
Symbol  
VDD  
Pin  
1
Description  
VDD power supply connection (1.95 to 3.6 V)  
External capacitor  
CAP  
2
GND  
VDDIO  
INT2  
INT1  
SDL  
3
Ground  
4
Digital interface power supply (1.62 to 3.6 V)  
Pressure interrupt 2  
5
6
Pressure interrupt 1  
7
I2C serial data  
SCL  
8
I2C serial clock  
7 Handling and board mount recommendations  
The sensor die is sensitive to light exposure. Direct light exposure through the port hole  
can lead to varied accuracy of pressure measurement. Avoid such exposure to the port  
during normal operation.  
7.1 Methods of handling  
Components can be picked from the carrier tape using either the vacuum assist or the  
mechanical type pickup heads. A vacuum assist nozzle type is most common due to its  
lower cost of maintenance and ease of operation. The recommended vacuum nozzle  
configuration should be designed to make contact with the device directly on the metal  
cover and avoid vacuum port location directly over the vent hole in the metal cover of the  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
3 / 14  
 
 
 
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
device. Multiple vacuum ports within the nozzle may be required to effectively handle the  
device and prevent shifting during movement to placement position.  
Vacuum pressure required to adequately support the component should be  
approximately 25 in Hg (85kPa). This level is typical of in-house vacuum supply.  
Pickup nozzles are available in various sizes and configurations to suit a variety of  
component geometries. To select the nozzle best suited for the specific application, it  
is recommended that the customer consult their pick and place equipment supplier to  
determine the correct nozzle. In some cases it may be necessary to fabricate a special  
nozzle depending on the equipment and speed of operation.  
Tweezers or other mechanical forms of handling that have a sharp point are not  
recommended since they can inadvertently be inserted into the vent hole of the device.  
This can lead to a puncture of the MEMS element that will render the device inoperable.  
7.2 Board mount recommendations  
Components can be mounted using solder paste stencil, screen printed or dispensed  
onto the PCB pads prior to placement of the component. The volume of solder paste  
applied to the PCB is normally sufficient to secure the component during transport to the  
subsequent reflow soldering process. Use of adhesives to secure the component is not  
recommended, but where necessary can be applied to the underside of the device.  
Solder pastes are available in variety of metal compositions, particle size and flux types.  
The solder paste consists of metals and flux required for a reliable connection between  
the component lead and the PCB pad. Flux aids the removal of oxides that may be  
present on PCB pads and prevents further oxidation from occurring during the solder  
process.  
The use of a No-Clean (NC) flux is recommended for exposed cavity components.  
Using pressure spray, wire brush, or other methods of cleaning is not recommended  
since it can puncture the MEMS device and render it unusable. If cleaning of the pcb  
is performed Water Soluble (WS) flux can be used. However, it is recommended the  
component cavity is protected by adhesive Kapton tape, vinyl cap or other means  
prior to the cleaning process. This covering will prevent damage to the MEMS device,  
contamination, and foreign materials from being introduced into device cavity as result of  
cleaning processes.  
Ultrasonic cleaning is not recommended as the frequencies can damage wire bond  
interconnections and the MEMS device.  
8 Mechanical and electrical specifications  
8.1 Absolute maximum ratings  
Absolute maximum ratings are the limits the device can be exposed to without  
permanently damaging it. Absolute maximum ratings are stress ratings only, functional  
operation at these ratings is not guaranteed. Exposure to absolute maximum ratings  
conditions for extended periods may affect device reliability.  
This device contains circuitry to protect against damage due to high static voltage  
or electrical fields. It is advised, however, that normal precautions be taken to avoid  
application of any voltages higher than maximum-rated voltages to this high-impedance  
circuit.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
4 / 14  
 
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
Table 3.ꢀMaximum ratings  
Symbol  
Pmax  
VDD  
Characteristic  
Value  
500  
Unit  
kPa  
V
Maximum applied pressure  
Supply voltage  
−0.3 to 3.6  
−0.3 to 3.6  
−0.3 to VDDIO + 0.3  
−40 to +85  
−40 to +125  
VDDIO  
VIN  
Interface supply voltage  
V
Input voltage on any control pin (SCL, SDA)  
Operating temperature range  
Storage temperature range  
V
TOP  
°C  
°C  
TSTG  
Table 4.ꢀESD and latchup protection characteristics  
Symbol  
HBM  
CDM  
Rating  
Value  
±2000  
±500  
Unit  
V
Human body model  
Charge device model  
V
Latchup current at T = 85 °C  
±100  
mA  
Caution  
This device is sensitive to mechanical shock. Improper handling can cause permanent damage to the part or  
cause the part to otherwise fail.  
Caution  
This is an ESD sensitive device. Improper handling can cause permanent damage to the part.  
msc896  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
5 / 14  
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
8.2 Mechanical characteristics  
Table 5.ꢀMechanical characteristics  
VDD = 2.5 V, T = 25 °C, over 50 kPa to 110 kPa, unless otherwise noted.  
Symbol  
Parameter  
Test conditions  
Min  
Typ  
Max  
Unit  
Pressure sensor  
PFS Measurement range  
Calibrated range  
50  
20  
––  
––  
19  
1.5  
––  
110  
110  
––  
kPa  
kPa  
Operational range  
1x oversample  
Pressure reading noise [1]  
––  
Pa RMS  
Pa RMS  
kPa  
128x oversample  
––  
––  
Pressure absolute accuracy 50 to 110 kPa over 0 °C to  
50 °C  
–0.75  
0.75  
50 to 110 kPa over −10 °C to  
70 °C  
––  
––  
±0.75  
±0.05  
––  
––  
kPa  
kPa  
Pressure relative accuracy  
Relative accuracy during  
pressure change between 70  
to 110 kPa at any constant  
temperature between −10 °C  
to 50 °C  
Relative accuracy during  
changing temperature  
––  
±0.1  
––  
kPa  
between −10 °C to 50 °C  
at any constant pressure  
between 50 kPa to 110 kPa  
Pressure/altitude resolution Barometer mode  
0.25  
0.0625  
––  
1.5  
0.3  
––  
––  
Pa  
m
[2][3][4]  
Altimeter mode  
Output data rate  
One-shot mode  
FIFO mode  
100  
––  
––  
Hz  
––  
1
Hz  
Board mount drift  
Long term drift  
After solder reflow  
After a period of 1 year  
–0.45  
–0.3  
±0.15  
±0.1  
0.45  
0.3  
kPa  
kPa  
Temperature sensor  
TFS Measurement range  
––  
–40  
––  
––  
±1  
±3  
––  
+85  
––  
°C  
°C  
°C  
°C  
Temperature accuracy  
@25 °C  
Over temperature range  
––  
––  
––  
TOP  
Operating temperature  
range  
–40  
+85  
[1] Oversample (OSR) modes internally combine and average samples to reduce noise.  
[2] Smallest bit change in register represents minimum value change in Pascals or meters. Typical resolution to signify change in altitude is 0.3 m.  
[3] Reference pressure = 101.325 kPa (sea level).  
[4] At 128x oversample ratio.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
6 / 14  
 
 
 
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
8.3 Electrical characteristics  
Table 6.ꢀElectrical characteristics  
@ VDD = 2.5 V, T = 25 °C unless otherwise noted.  
Symbol  
VDDIO  
VDD  
Parameter  
Test conditions  
Min  
1.62  
1.95  
Typ  
1.8  
Max  
3.6  
3.6  
Unit  
V
I/O supply voltage  
Operating supply voltage  
2.5  
V
IDD  
Integrated current 1 update  
per second  
Highest speed mode  
oversample = 1  
8.5  
µA  
Standard mode oversample  
= 16  
40  
265  
2
µA  
µA  
High resolution mode  
oversample = 128  
IDDMAX  
IDDSTBY  
VIH  
Max current during  
acquisition and conversion  
During acquisition/  
conversion  
mA  
Supply current drain in  
STANDBY mode  
STANDBY mode selected  
SBYB = 0  
2
µA  
Digital high level input  
voltage  
0.75  
VDDIO  
SCL, SDA  
VIL  
Digital low level input voltage —  
SCL, SDA  
0.9  
0.3  
VDDIO  
VDDIO  
VDDIO  
VDDIO  
VOH  
VOL  
VOLS  
TON  
High level output voltage  
INT1, INT2  
IO = 500 µA  
Low level output voltage  
INT1, INT2  
IO = 500 µA  
IO = 500 µA  
0.1  
0.1  
Low level output voltage  
SDA  
Turn-on time [1][2][3]  
High speed mode  
25  
60  
ms  
ms  
°C  
High resolution mode  
1000  
+85  
TOP  
Operating temperature range —  
−40  
I2C addressing  
I2C Address  
0x60  
Hex  
The device uses 7-bit addressing and does not acknowledge general call address 000 0000. Slave address has been set  
to 60h or 110 0000. 8-bit read is C1h, 8-bit write is C0h.  
[1] Time to obtain valid data from STANDBY mode to ACTIVE mode  
[2] High speed mode is achieved by setting the oversample rate of 1x.  
[3] High resolution mode is achieved by setting the oversample to 128x.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
7 / 14  
 
 
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
9 Package information  
9.1 Package dimensions  
This drawing is located at http://nxp.com/files/shared/doc/  
package_info/98ASA00260D.pdf.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
8 / 14  
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
Figure 3.ꢀCase 98ASA00260D, LGA package  
10 Soldering/landing pad information  
The LGA package is compliant with the RoHS standard.  
Note: Pin 1 index area marker does not have any internal electrical connections.  
Handling and soldering recommendations for pressure sensors are available in  
application notes AN1984 and AN3150.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
9 / 14  
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
Figure 4.ꢀRecommended PCB landing pattern  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
10 / 14  
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
11 Tape and reel specifications  
(I) Measured from centerline of sprocket hole to  
centerline of pocket.  
(II) Cumulative tolerance of 10 sprocket holes is  
±0.20.  
(III) Measured from centerline of sprocket hole to  
centerline of pocket.  
(IV) Other material available.  
Dimensions are in millimeters.  
Ao  
Bo  
Ko  
F
3.35 ± 0.10  
5.35 ± 0.10  
1.20 ± 0.10  
5.50 ± 0.10  
8.00 ± 0.10  
12.00 ± 0.10  
P1  
W
Figure 5.ꢀLGA 3 mm 5 mm embossed carrier tape dimensions  
Pin 1 Index Area  
Figure 6.ꢀDevice orientation in chip carrier  
12 Revision history  
Table 7.ꢀRevision history  
Document ID  
Release date  
Data sheet status  
Change notice  
Supercedes  
FXPQ3115BVSDS v.1 20171009  
Technical data  
n.a.  
n.a.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
11 / 14  
 
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
13 Legal information  
13.1 Data sheet status  
Document status[1][2]  
Product status[3]  
Definition  
[short] Data sheet: product preview  
Development  
This document contains certain information on a product under development.  
NXP reserves the right to change or discontinue this product without notice.  
[short] Data sheet: advance information  
[short] Data sheet: technical data  
Qualification  
Production  
This document contains information on a new product. Specifications and  
information herein are subject to change without notice.  
This document contains the product specification. NXP Semiconductors  
reserves the right to change the detail specifications as may be required to  
permit improvements in the design of its products.  
[1] Please consult the most recently issued document before initiating or completing a design.  
[2] The term 'short data sheet' is explained in section "Definitions".  
[3] The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple  
devices. The latest product status information is available on the Internet at URL http://www.nxp.com.  
limitation specifications and product descriptions, at any time and without  
notice. This document supersedes and replaces all information supplied prior  
13.2 Definitions  
to the publication hereof.  
Draft — The document is a draft version only. The content is still under  
internal review and subject to formal approval, which may result in  
Suitability for use — NXP Semiconductors products are not designed,  
authorized or warranted to be suitable for use in life support, life-critical or  
modifications or additions. NXP Semiconductors does not give any  
safety-critical systems or equipment, nor in applications where failure or  
representations or warranties as to the accuracy or completeness of  
malfunction of an NXP Semiconductors product can reasonably be expected  
information included herein and shall have no liability for the consequences  
to result in personal injury, death or severe property or environmental  
of use of such information.  
damage. NXP Semiconductors and its suppliers accept no liability for  
inclusion and/or use of NXP Semiconductors products in such equipment or  
Short data sheet — A short data sheet is an extract from a full data sheet  
applications and therefore such inclusion and/or use is at the customer’s own  
with the same product type number(s) and title. A short data sheet is  
risk.  
intended for quick reference only and should not be relied upon to contain  
detailed and full information. For detailed and full information see the  
relevant full data sheet, which is available on request via the local NXP  
Applications — Applications that are described herein for any of these  
products are for illustrative purposes only. NXP Semiconductors makes  
Semiconductors sales office. In case of any inconsistency or conflict with the  
no representation or warranty that such applications will be suitable  
short data sheet, the full data sheet shall prevail.  
for the specified use without further testing or modification. Customers  
are responsible for the design and operation of their applications and  
Product specification — The information and data provided in a  
products using NXP Semiconductors products, and NXP Semiconductors  
technical data data sheet shall define the specification of the product as  
accepts no liability for any assistance with applications or customer product  
agreed between NXP Semiconductors and its customer, unless NXP  
design. It is customer’s sole responsibility to determine whether the NXP  
Semiconductors and customer have explicitly agreed otherwise in writing.  
Semiconductors product is suitable and fit for the customer’s applications  
In no event however, shall an agreement be valid in which the NXP  
and products planned, as well as for the planned application and use of  
Semiconductors product is deemed to offer functions and qualities beyond  
customer’s third party customer(s). Customers should provide appropriate  
those described in the technical data data sheet.  
design and operating safeguards to minimize the risks associated with  
their applications and products. NXP Semiconductors does not accept any  
liability related to any default, damage, costs or problem which is based  
on any weakness or default in the customer’s applications or products, or  
the application or use by customer’s third party customer(s). Customer is  
responsible for doing all necessary testing for the customer’s applications  
13.3 Disclaimers  
Limited warranty and liability — Information in this document is believed  
and products using NXP Semiconductors products in order to avoid a  
to be accurate and reliable. However, NXP Semiconductors does not  
default of the applications and the products or of the application or use by  
give any representations or warranties, expressed or implied, as to the  
customer’s third party customer(s). NXP does not accept any liability in this  
accuracy or completeness of such information and shall have no liability  
respect.  
for the consequences of use of such information. NXP Semiconductors  
takes no responsibility for the content in this document if provided by an  
information source outside of NXP Semiconductors. In no event shall NXP  
Limiting values — Stress above one or more limiting values (as defined in  
the Absolute Maximum Ratings System of IEC 60134) will cause permanent  
Semiconductors be liable for any indirect, incidental, punitive, special or  
damage to the device. Limiting values are stress ratings only and (proper)  
consequential damages (including - without limitation - lost profits, lost  
operation of the device at these or any other conditions above those  
savings, business interruption, costs related to the removal or replacement  
given in the Recommended operating conditions section (if present) or the  
of any products or rework charges) whether or not such damages are based  
Characteristics sections of this document is not warranted. Constant or  
on tort (including negligence), warranty, breach of contract or any other  
repeated exposure to limiting values will permanently and irreversibly affect  
the quality and reliability of the device.  
legal theory. Notwithstanding any damages that customer might incur for  
any reason whatsoever, NXP Semiconductors’ aggregate and cumulative  
liability towards customer for the products described herein shall be limited  
in accordance with the Terms and conditions of commercial sale of NXP  
Semiconductors.  
Terms and conditions of commercial sale — NXP Semiconductors  
products are sold subject to the general terms and conditions of commercial  
sale, as published at http://www.nxp.com/profile/terms, unless otherwise  
agreed in a valid written individual agreement. In case an individual  
agreement is concluded only the terms and conditions of the respective  
agreement shall apply. NXP Semiconductors hereby expressly objects to  
Right to make changes — NXP Semiconductors reserves the right to  
make changes to information published in this document, including without  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
12 / 14  
 
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
applying the customer’s general terms and conditions with regard to the  
purchase of NXP Semiconductors products by customer.  
use the product without NXP Semiconductors’ warranty of the product for  
such automotive applications, use and specifications, and (b) whenever  
customer uses the product for automotive applications beyond NXP  
Semiconductors’ specifications such use shall be solely at customer’s own  
risk, and (c) customer fully indemnifies NXP Semiconductors for any liability,  
damages or failed product claims resulting from customer design and use  
of the product for automotive applications beyond NXP Semiconductors’  
standard warranty and NXP Semiconductors’ product specifications.  
No offer to sell or license — Nothing in this document may be interpreted  
or construed as an offer to sell products that is open for acceptance or  
the grant, conveyance or implication of any license under any copyrights,  
patents or other industrial or intellectual property rights.  
Export control — This document as well as the item(s) described herein  
may be subject to export control regulations. Export might require a prior  
authorization from competent authorities.  
Translations — A non-English (translated) version of a document is for  
reference only. The English version shall prevail in case of any discrepancy  
between the translated and English versions.  
Non-automotive qualified products — Unless this data sheet expressly  
states that this specific NXP Semiconductors product is automotive qualified,  
the product is not suitable for automotive use. It is neither qualified nor  
tested in accordance with automotive testing or application requirements.  
NXP Semiconductors accepts no liability for inclusion and/or use of non-  
automotive qualified products in automotive equipment or applications. In  
the event that customer uses the product for design-in and use in automotive  
applications to automotive specifications and standards, customer (a) shall  
13.4 Trademarks  
Notice: All referenced brands, product names, service names and  
trademarks are the property of their respective owners.  
NXP — is a trademark of NXP B.V.  
FXPQ3115BVSDS  
All information provided in this document is subject to legal disclaimers.  
© NXP B.V. 2017. All rights reserved.  
Short data sheet: technical data  
Rev. 1 — 9 October 2017  
13 / 14  
NXP Semiconductors  
FXPQ3115BV  
I2C precision pressure sensor with altimetry  
Contents  
1
General description ............................................ 1  
2
3
4
5
Features and benefits .........................................1  
Applications .........................................................2  
Ordering information .......................................... 2  
Block diagram ..................................................... 2  
Pinning information ............................................ 3  
Pinning ...............................................................3  
Pin description ...................................................3  
6
6.1  
6.2  
7
Handling  
and  
board  
mount  
recommendations ............................................... 3  
Methods of handling ..........................................3  
Board mount recommendations .........................4  
Mechanical and electrical specifications .......... 4  
Absolute maximum ratings ................................ 4  
Mechanical characteristics .................................6  
Electrical characteristics .................................... 7  
Package information ...........................................8  
Package dimensions ..........................................8  
Soldering/landing pad information ....................9  
Tape and reel specifications ............................11  
Revision history ................................................ 11  
Legal information ..............................................12  
7.1  
7.2  
8
8.1  
8.2  
8.3  
9
9.1  
10  
11  
12  
13  
Please be aware that important notices concerning this document and the product(s)  
described herein, have been included in section 'Legal information'.  
© NXP B.V. 2017.  
All rights reserved.  
For more information, please visit: http://www.nxp.com  
For sales office addresses, please send an email to: salesaddresses@nxp.com  
Date of release: 9 October 2017  
Document identifier: FXPQ3115BVSDS  

相关型号:

FXPS7115D4

Digital absolute pressure sensor, 40 kPa to 115 kPa
NXP

FXPS7115DI4

Digital absolute pressure sensor, 40 kPa to 115 kPa
NXP

FXPS7115DI4T1

Capacitive Sensor
NXP

FXPS7115DS4

Digital absolute pressure sensor, 40 kPa to 115 kPa
NXP

FXPS7115DS4T1

Digital absolute pressure sensor, 40 kPa to 115 kPa
NXP

FXPS7165D4

Digital absolute pressure sensor, 60 to 165 kPa
NXP

FXPS7165DI4

Digital absolute pressure sensor, 60 to 165 kPa
NXP

FXPS7165DI4T1

Digital absolute pressure sensor, 60 to 165 kPa
NXP

FXPS7165DS4

Digital absolute pressure sensor, 60 to 165 kPa
NXP

FXPS7165DS4T1

Digital absolute pressure sensor, 60 to 165 kPa
NXP

FXPS7250A4

Analog absolute pressure sensor, 20 to 250 kPa
NXP

FXPS7250A4T1

Analog absolute pressure sensor, 20 to 250 kPa
NXP