D4CC-1060 [OMRON]
Snap Acting/Limit Switch, SPDT, Momentary, Wire Terminal, Center Roller Lever Actuator, Panel Mount;型号: | D4CC-1060 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Snap Acting/Limit Switch, SPDT, Momentary, Wire Terminal, Center Roller Lever Actuator, Panel Mount 开关 光电二极管 |
文件: | 总12页 (文件大小:363K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Slim Connector-Ready Limit Switches
D4CC
Compact, Enclosed Limit Switch
ꢀ Connector-ready for quick replacement
ꢀ New center roller lever model for
compact installation and gang
mounting
ꢀ Triple-seal construction meets UL
Types 3, 4, and 13
ꢀ Panel-mount types available
ꢀ Microchange™ connector cordsets
available
ꢀ UL/CSA approvals
Ordering Information
ꢀ LIMIT SWITCHES
Actuator
Part Number
1 A at 125 VAC
D4CC-1001
D4CC-1002
D4CC-1003
D4CC-1010
D4CC-1024
D4CC-1031
D4CC-1032
D4CC-1033
D4CC-1041
D4CC-1042
D4CC-1043
D4CC-1050
D4CC-1060
1 A at 30 VDC
D4CC-3001
D4CC-3002
D4CC-3003
D4CC-3010
D4CC-3024
D4CC-3031
D4CC-3032
D4CC-3033
D4CC-3041
D4CC-3042
D4CC-3043
D4CC-3050
D4CC-3060
Pin plunger
Roller plunger
Cross roller plunger
Bevel plunger
Low operating force roller lever
Sealed plunger
Sealed roller plunger
Sealed cross roller plunger
Panel mount pin plunger
Panel mount roller plunger
Panel mount cross roller plunger
Plastic rod
Center roller lever
MicroChange–Reg TM Woodhead Industries
Part Numbers for LED Models:
AC: Substitute a number 2 for the number 1 in the Part Number. Example: D4CC-2001
DC: Substitute a number 4 for the number 3 in the Part Number. Example: D4CC-4001
2
D4CC
D4CC
ꢀ ACCESSORIES
Description
Part number
For AC limit switches
For DC limit switches
2 m (6.56 ft) cable length
5 m (16.40 ft) cable length
2 m (6.56 ft) cable length
5 m (16.40 ft) cable length
For D4CC-ꢀ001
XS2F-A421-D90-A
XS2F-A421-G90-A
XS2F-D421-D80-A
XS2F-D421-G80-A
D4CC-P001
Connector cordsets,
with straight connector,
4-conductor
Panel mounting adapters to replace standard size
(WL) limit switches with D4CC
For D4CC-ꢀ002
D4CC-P002
For D4CC-ꢀ020
D4CC-P020
Construction
Specifications
ꢀ RATINGS
Rated voltage
Non-inductive load (A)
Resistive load Lamp load
Inductive load (A)
Inductive load
Inrush current (A)
Motor load
NC
1 A
1 A
NO
1 A
1 A
NC
1 A
1 A
NO
NC
1 A
1 A
NO
1 A
1 A
NC
1 A
1 A
NO
NC
5 A
NO
125 VAC
30 VDC
0.7 A
1 A
1 A
1 A
2.5 max.
Note: 1. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
2. Lamp loads have an inrush current of 10 times the steady-state current.
3. Motor loads have an inrush current of 6 times the steady-state current.
3
D4CC
D4CC
ꢀ CHARACTERISTICS
Enclosure ratings
UL
Types 3, 4 and 13
NEMA
IEC 144
Types 1, 3, 3R, 4, 5, 6, 12 and 13
IP67
Mechanical life
10,000,000 operations min.
-10°C to 70°C (14°F to 158°F)
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Approx. 50 G
Ambient operating temperature
Vibration
Shock
Malfunction durability
Malfunction durability
Mechanical durability
Approx. 100 G
ꢀ OPERATING CHARACTERISTICS
Legend: OF = Operating Force (max.); RF = Reset Force (min.); OT = Overtravel (min.); PT = Pretravel
MD = Movement Differential (max.); TT = Total Travel; OP = Operating Position
Part number
OF max.
RF min.
OT min.
PT max.
MD max.
TT
OP
D4CC-ꢀ001
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
1.8 mm
(0.07 in)
15.7 ±1 mm
(0.62 ±0.04 in)
D4CC-ꢀ002
D4CC-ꢀ003
D4CC-ꢀ010
D4CC-ꢀ024
D4CC-ꢀ031
D4CC-ꢀ032
D4CC-ꢀ033
D4CC-ꢀ041
D4CC-ꢀ042
D4CC-ꢀ043
D4CC-ꢀ050
D4CC-ꢀ060
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
1.8 mm
(0.07 in)
28.5 ±1 mm
(1.12 ±0.04 in)
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
1.8 mm
(0.07 in)
28.5 ±1 mm
(1.12 ±0.04 in)
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
1.8 mm
(0.07 in)
28.5 ±1 mm
(1.12 ±0.04 in)
0.58 kg
(20.46 oz)
0.15 kg
(5.29 oz)
50°
10°+3°
3°
10°+3°
—
1.8 kg
(63.49 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
24.9 ±1 mm
(0.98 ±0.04 in)
1.8 kg
(63.49 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
34.3 ±1 mm
(1.35 ±0.04 in)
1.8 kg
(63.49 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
34.3 ±1 mm
(1.35 ±0.04 in)
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
31.2 ±1 mm
(1.23 ±0.04 in)
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
36.8 ±1 mm
(1.45 ±0.04 in)
1.2 kg
(42.33 oz)
0.45 kg
(15.87 oz)
3 mm
(0.12 in)
1.8 mm
(0.07 in)
0.2 mm
(0.008 in)
5 mm
(0.20 in)
36.8 ±1 mm
(1.45 ±0.04 in)
0.15 kg
(5.29 oz)
—
—
15°
—
—
—
—
—
0.68 kg
(23.99 oz)
0.15 kg
(5.29 oz)
50°
10°+3°
3°
4
D4CC
D4CC
Engineering Data
ꢀ ELECTRICAL SERVICE LIFE
ꢀꢀꢀCONTACT RATINGS
NEMA B300
ꢀꢀꢀCONTACT RESISTANCE
100 mΩ
ꢀꢀꢀELECTRICAL APPROVALS
UL Recognized, File No. E76675
CSA Certified, File No. LR45746
Note: Approvals pending for DC types
Switching current (mA)
Operation
ꢀ CONTACT FORM
Connector pin
AC type
DC type
Dimensions
Unit: mm (inch)
ꢀ LIMIT SWITCHES
Plunger Switches
D4CC- 001
ꢀ
5
ꢀ
ꢀ
D4CC
D4CC
Roller Plunger Switches
D4CC- 002
ꢀ
Cross Roller Plunger Switches
D4CC- 003
Bevel Plunger Switches
D4CC- 010
6
ꢀ
ꢀ
D4CC
D4CC
Unit: mm (inch)
Roller Lever Switches
D4CC- 024
ꢀ
Sealed Plunger Switches
D4CC- 031
Sealed Roller Plunger Switches
D4CC- 032
7
ꢀ
ꢀ
D4CC
D4CC
Sealed Cross Roller Plunger Switches
D4CC- 033
ꢀ
Panel-Mount Pin Plunger Switches
D4CC- 041
Panel-Mount Roller Plunger Switches
D4CC- 042
8
ꢀ
ꢀ
D4CC
D4CC
Unit: mm (inch)
Panel-Mount Cross Roller Switches
D4CC- 043
ꢀ
Plastic Rod Switches
D4CC- 050
Center Roller Lever Switches
D4CC- 060
9
D4C-P001 (For D4CC- 001)
ꢀ
D4C-P002 (For D4CC- 002)
ꢀ
D4CC
D4CC
ꢀ CONNECTOR CABLES
Y96E-44SA
ꢀ
(AC)
Y96E-44SD
ꢀ
(DC)
AC Type
DC Type
ꢀ SPECIAL MOUNTING PLATES
: Four hexagonal flat head bolts (M5 x 0.8,
h: 10) and two hexagonal head
bolts (M5 x 0.8, length: 15) are included.
*All the holes with 5.2+0.2/0 dia. must be used
with M5 x 10 hexagonal head bolts.
**All the M5-tapped holes must be used with M5
hexagonal flat head bolts.
10
D4CC
D4CC
Unit: mm (inch)
D4C-P020 (For D4CC- 020)
ꢀ
Note: Four hexagonal flat head bolts (M5 x 0.8,
length: 10) and two hexagonal head
bolts (M5 x 0.8, length: 15) are included.
*All the holes with 5.2+0.2/0 dia. must be used
with M5 x 10 hexagonal head bolts.
**All the M5-tapped holes must be used with M5
hexagonal flat head bolts.
11
D4CC
D4CC
Installation
ꢀ MOUNTING HOLES
ꢀ OPERATION
Secure the switch to the mounting panel with M5 hexagonal head
bolts and washers with a tightening torque of 50 to 60 kg•cm
(34.4 to 41.3 in•lbs).
The method and frequency of operation, the shape of the cam
and dog, and the overtravel value have a significant influence on
the service life and precision of a D4CC Limit Switch. For this
reason, the dog angle must be 30° max.; the surface roughness
of the dog must be 6.3 microns max.; and, the hardness of the
dog must be about Hv450.
To allow the plunger actuator to travel properly, adjust the
position of the pin, roller, or bevel plunger with the dog or cam
stroke so that the plunger is displaced to the groove part of the
plunger (correct setting position) properly.
ꢀ GANG MOUNTING SWITCHES
A maximum of six switches can be gang mounted. In this case,
the convex part of the gang-mount guide on a switch must fit into
the concave part of the guide on another switch as shown in the
figure. A mounting panel with a thickness of 6 mm min. should be
used.
To allow the roller lever actuator to travel properly, adjust the
position of the lever with the dog or cam stroke so that the
arrowhead of the lever is positioned between the two convex
markers as shown. The arrowhead indicates the proper stroke
travel.
The D4CC is designed so that gang mounted switches are
physically secure to one another.
Secure the head of a D4CC Limit Switch with a tightening torque
of 3.5 to 4.5 kg•cm (2.4 to 3.1 in•lbs) after changing the position
of the head.
12
D4CC
D4CC
To allow the center roller lever actuator to travel properly, adjust
the position of the lever with the dog or cam stroke so that part A
(the convex part) of the lever is positioned in the convex part of
the head.
ꢀ ENVIRONMENT
Avoid using D4CC Limit Switches in steamy places or where
subject to hot water (70°C or higher).
ꢀ SPECIAL MOUNTING PLATE
The D4CC is a SPDT limit switch for standard loads. The WLA_
cannot be replaced with a D4CC Limit Switch since the WLA_
contacts are normally open.
There is no difference in dimension between the mounting holes
of the WL and those of the D4CC. The D4CC is, however, thinner
than the WL model. Thus space can be saved if WL Limit
Switches are replaced with D4CC Limit Swithces mounted on
Special Mounting Plates.
Refer to the following figure to set the stroke of a D4CC Limit
Switch mounted on a panel.
The bottom of the enclosed switch at the cable outlet is resin-
molded. Secure the cable at a point 5 cm from the switch bottom
to prevent exertion of excess force on the cable.
Turn screw B clockwise by hand to secure it with part C so that
part C is covered with scerw B until the width of A is nearly zero.
If the tightening force is not enough, the screw can be loosened
by vibration. Do not use pliers to tighten the screw, or the
connector could be broken. Always tighten the screw securely
by hand.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
OMRON ON-LINE
OMRON CANADA, INC.
885 Milner Avenue
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice.
Printed in the U.S.A.
相关型号:
D4CC-2001
Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Pin Plunger Actuator, Panel Mount
OMRON
D4CC-2002
Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Roller Plunger Actuator, Panel Mount
OMRON
D4CC-2031
Snap Acting/Limit Switch, SPDT, Momentary, 4.8mm, Wire Terminal, Sealed Pin Plunger Actuator, Panel Mount
OMRON
D4CC-2032
Snap Acting/Limit Switch, SPDT, Momentary, 3.8mm, Wire Terminal, Sealed Roller Plunger Actuator, Panel Mount
OMRON
D4CC-2050
Snap Acting/Limit Switch, SPDT, Momentary, Wire Terminal, Plastic Rod Actuator, Panel Mount
OMRON
D4CC-2060
Snap Acting/Limit Switch, SPDT, Momentary, Wire Terminal, Center Roller Lever Actuator, Panel Mount
OMRON
D4CC-3001
Snap Acting/Limit Switch, SPDT, Momentary, 1A, 30VDC, 4.8mm, Wire Terminal, Pin Plunger Actuator, Panel Mount
OMRON
D4CC-3002
Snap Acting/Limit Switch, SPDT, Momentary, 1A, 30VDC, 4.8mm, Wire Terminal, Roller Plunger Actuator, Panel Mount
OMRON
D4CC-3050
Snap Acting/Limit Switch, SPDT, Momentary, 1A, 30VDC, Wire Terminal, Plastic Rod Actuator, Panel Mount
OMRON
D4CC-3060
Snap Acting/Limit Switch, SPDT, Momentary, 1A, 30VDC, Wire Terminal, Center Roller Lever Actuator, Panel Mount
OMRON
©2020 ICPDF网 联系我们和版权申明