D4V-8104Z [OMRON]
Small Limit Switch;型号: | D4V-8104Z |
厂家: | OMRON ELECTRONICS LLC |
描述: | Small Limit Switch |
文件: | 总8页 (文件大小:346K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Small Limit Switch
D4V
Compact Vertical Models Sized for Asian
Standards
• Compact new design approximately 1/3 the size of OMRON
vertical Limit Switches.
• Structure enables the terminal section to be fully opened for
easy wiring.
• RoHS complaint.
• Degree of protection: IP65
Model Number Structure
■ Model Number Legend
D4V-81@@Z
1
1. Actuator type
04: Roller lever
12: Roller plunger
22: Crossroller plunger
66: Coil spring
07: Rod lever
08: Adjustable roller lever
11: Push plunger
69: Wire spring
Ordering Information
■ List of Models
Actuator type
Model
Roller lever
Rod lever
D4V-8104Z
D4V-8107Z
Adjustable roller lever
D4V-8108Z
Push plunger
Roller plunger
D4V-8111Z
D4V-8112Z
Crossroller plunger
Coil spring
D4V-8122Z
D4V-8166Z
Wire spring
D4V-8169Z
Note: Metallic roller levers and metallic variable roller levers can also be manufactured.
Small Limit Switch D4V
1
Specifications
■ Certified Standards
■ Characteristics
Certification body
Standard
File No.
Degree of protection
IP65
CCC
GB14048.5
Consult your OMRON
representative for
details.
Durability
(See note 3.)
Mechanical 10,000,000 operations min.
UL (See note.)
UL508,
CSA C22.2 No. 14
Electrical
300,000 operations min.
(5 A at 250 VAC, resistive load)
TÜV
IEC60947-5-1
Operating speed
5 mm to 0.5 m/s
Operating
frequency
Mechanical 120 operations/min
Note: Certification equivalent to CSA C22.2 No. 14 has been
Electrical
30 operations/min
obtained from UL.
Insulation resistance
Contact resistance
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1 min
■ Ratings
Dielectric
strength
Between
terminalsof
the same
polarity
Rated
voltage
(V)
Non-inductive load (A)
Inductive load (A)
Resistive load Lamp load
Inductive load Motor load
NC
NO
NC
NO
NC
NO
NC
NO
Between
current-
1,500 VAC, 50/60 Hz for 1 min
125 VAC
250 VAC
5
5
1.5
1
0.7
0.5
3
3
2
1.5
1
0.8
carrying
metal parts
and ground
12 VDC
24 VDC
5
5
3
3
4
4
3
3
125 VDC
250 VDC
0.4
0.4
0.2
0.2
---
---
---
---
---
---
Rated insulation voltage 250 V
(Ui)
Note: 1. The above current ratings are for steady-state current.
Pollution degree
(application environment)
3 (EN 60947-5-1)
2. Inductive load has a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
Short-circuit protection
device
10-A fuse, gG or gI (IEC 269)
3. Lamp load has an inrush current of 10 times the steady-
state current.
Conditional short-circuit 100 A (EN 60947-5-1)
current
4. Motor load has an inrush current of 6 times the steady-state
current.
Rated open thermal
current (lth)
5 A (EN 60947-5-1)
Inrush current NC
NO
24 A max.
12 A max.
Electric shock protection Class I
class
Rated frequency
50/60 Hz
■ Ratings for Safety Standard
Vibration
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
Certification
resistance
(See note 4.)
Shock
Destruction 1,000 m/s2 (free position) min.
CCC (GB14048.5), TÜV (EN60947-5-1)
resistance
Malfunction 300 m/s2 (operation limit position) min.
(See note 4.)
Category and rating
Ambient operating
temperature range
−20°C to 60°C (with no icing)
AC-12: 250 VAC at 5 A, resistive load
DC-12: 125 VDC at 0.4 A, resistive load
Ambient operating
humidity range
90% max.
UL (UL508, CSA C22.2 No. 14)
Weight
Approx. 130 to 190 g
Ratings
Note: 1. The above values are initial values.
5 A, 250 VAC
0.4 A, 125 VDC
2. The above characteristics may vary depending on the
model. Contact your OMRON representative for further
details.
3. Durability values are calculated at an operating temperature
of 5°C to 35°C, and an operating humidity of 40% to 70%.
4. Except for the coil spring model and wire spring model
2
Small Limit Switch D4V
Nomenclature
■ Structure
■ Contact Form
Za
Resin roller
Lever
(NO) 4
3 (NO)
2 (NC)
(NC) 1
Head
4
NO
1
3
NO
2
Cover
NC
NC
Built-in Switch
Connector
Engineering Data
Electrical Durability: cos φ = 1
(Ambient temperature: 5°C to 35°C; ambient humidity: 40% to 70%)
Operating frequencies: 30 operations/min
1,000
125 VAC, cos φ = 1
500
0
1
2
3
4
5
6
Switching current (A)
Small Limit Switch D4V
3
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Roller Lever
Rod Lever
D4V-8104Z
D4V-8107Z
42.8±0.8
39.6±0.8
18-dia. × 6.2
5.7
2.6 dia. × 125.1
35.6±
0.8
34.4±0.8
(See note.)
Four, M5,
P=0.8,
Depth:
(See note.)
Four, M5,
P=0.8,
Depth:
M4 (length: 10),
hexagonal hole
7.5 min.
115 max.
7.5 min.
Three, M3,
P=0.5
R30
Three, M3,
P=0.5
M6 (length: 6),
hexagonal hole
18.3
18.3
M4
12.5
12.5
(125.3)
(length: 13),
hexagonal
hole
56±0.2
56±
0.2
64
64
Four, 4.2-dia
mounting holes
4
(14.3)
Four, 4.2-dia
mounting holes
4
(14.3)
(10.5)
(3.45)
7.2
(10.5)
(3.45)
7.2
14.7
21
±
0.2
21
±
0.2
14.7
25.4
25.4
27.8
27.8
37.5±0.8
Note: Resin Roller
Note: Stainless steel
Adjustable Roller Lever
Push Plunger
D4V-8108Z
D4V-8111Z
Four, M5,
6.6 dia. (See note.)
R0.2
46.5±0.8
41.6±0.8
18-dia. × 6.2
10.4
P=0.8,
Depth:
7.5 min.
PT
(See note.)
Four, M5,
3-M3*P0.5
P=0.8,
Depth:
7.5 min.
M4 (length: 10),
hexagonal hole
18.7
OP
Adjustable
up to R30
to R75
Three, M3,
P=0.5
M6
18.3
(length: 6),
(113.4)
56±0.2
12.5
hexagonal
hole
64
56±0.2
64
Four, 4.2-dia
mounting holes
4
(14.3)
(10.5)
7.2
(3.45) 21
±0.2
14.7
25.4
4
Four, 4.2-dia
mounting holes
(14.3)
27.8
(10.5)
(3.45)
7.2
Note: Stainless steel
21
±0.2
14.7
25.4
27.8
Note: Resin Roller
44.7±0.8
Roller Plunger
Crossroller Plunger
D4V-8112Z
D4V-8122Z
12.4-dia. × 3.9
(See note.)
10.4
10.4
Four, M5,
P=0.8
Four, M5,
P=0.8,
PT
12.4 dia. × 3.9 (See note.)
PT
Depth:
7.5 min.
Depth:
7.5 min.
Three, M3, P=0.5
Three, M3, P=0.5
OP
OP
18.7
18.7
(113.4)
(113.4)
64
56±0.2
64
56±0.2
Four, 4.2-dia
mounting holes
Four, 4.2-dia
mounting holes
4
(10.5)
(3.45)
(14.3)
4
(10.5)
(3.45)
(14.3)
7.2
7.2
21
±0.2
14.7
25.4
21
±0.2
14.7
25.4
27.8
27.8
Note: Stainless steel
Note: Stainless steel
4
Small Limit Switch D4V
Coil Spring
Wire Spring
D4V-8166Z
D4V-8169Z
PT
3 dia.
1.2 dia.
(See note.)
(See note.)
83.5
41.1
Four, M5,
P=0.8,
Depth: 7.5 min.
5.8 dia.
Four, M5,
P=0.8,
Depth:
100
Three, M3,
P=0.5
Three, M3, P=0.5
40
7.5 min.
13.6
(176)
(177)
64
56±0.2
56±0.2
64
Four, 4.2-dia
mounting holes
4
(14.3)
Four, 4.2-dia
mounting holes
4
(10.5)
(3.45)
(14.3)
(10.5)
(3.45)
7.2
7.2
21
±
0.2
14.7
25.4
21
±
0.2
14.7
25.4
27.8
27.8
Note: The range for operation is between
the tip of the rod and 1/3 of the length
of the actuator.
Note: The range for operation is between
the tip of the rod and 1/3 of the length
of the actuator.
Note: Unless otherwise specified, the tolerances are ±0.4 mm for the above dimensions for each model.
Operating Characteristics
Model D4V-8104Z D4V-8107Z D4V-8108Z D4V-8111Z D4V-8112Z D4V-8122Z D4V-8166Z D4V-8169Z
Operating characteristics
Operating force
Release force
OF max.
RF min.
PT max.
OT min.
MD max.
TT min.
OP
5.88 N
0.49 N
20°
75°
10°
5.88 N
0.69 N
20°
75°
10°
7.84 N
0.49 N
20°
75°
10°
9.8 N
2.94 N
1.5 mm
4 mm
9.8 N
2.94 N
1.5 mm
4 mm
9.8 N
2.94 N
1.5 mm
4 mm
0.88 N
---
0.88 N
---
Pretravel
30 mm
---
30 mm
---
Overtravel
Movement differential
Total travel
1.2 mm
5.5 mm
1.2 mm
5.5 mm
1.2 mm
5.5 mm
---
---
95°
---
95°
---
95°
---
---
---
Operating position
26 0.8 mm 37 0.8 mm 37 0.8 mm
---
---
Note: The operating characteristics of the D4V-8107 are measured with a lever length of 30 mm. The operating characteristics of the D4V-8108
are measured with a lever length of R30.
Small Limit Switch D4V
5
Precautions
Applicable Terminals
The following solderless terminals can be used.
■ Precautions for Correct Use
(Do not use fork or any other type of terminals, otherwise an
accidental disconnection resulting in a ground fault may result.)
Wiring
Terminal with insulated grip
Wiring Procedure
6.4 max.
6.4 max.
1. Loosen the cover mounting screws and remove the cover.
2. Run the wiring through the rubber connector on the cover and
then press-fit the solderless terminals. (The following solderless
terminals are available.)
3. After inserting the solderless terminal into the Switch, tighten the
14 max.
14 max.
terminal screws securely.
3.0 to 3.7 dia.
3.0 to 3.7 dia.
4. Mount the cover. (Make sure that the rubber connector is securely
pressed into the cover slot.)
5. Tighten the three screws evenly. (The optimum tightening torque
for each screw is 0.49 to 0.59 N·m.)
Appropriate Tightening Torque
If screws are too loose, they can lead to an early malfunction of the
Switch, so ensure that all screws are tightened using the correct
torque.
Cover mounting screw
Cover
No.
Type
Appropriate
tightening
torque
1
2
3
4
5
Head mounting screw
0.49 to 0.59 N·m
0.49 to 0.59 N·m
2.45 to 2.94 N·m
0.49 to 0.59 N·m
Cover mounting screw
Lever mounting screw
Terminal screw (M3)
Rubber connector
Terminals
Switch mounting screw (M4 Allen-head bolt) 2.45 to 2.94 N·m
Applicable Lead Wires
Note: In particular, when changing the direction of the Head, make
sure that all screws are tightened again to the correct torque.
Be careful not to allow any foreign substance to enter the
Switch.
Wire name
Applicable wire
Number of Conductor Finished
conductors
size
outside
diameter
0.75 mm2
Vinyl cabtire cord (VCTF) 2 conductors
3 conductors
Round,
6 to 9 dia.
4 conductors
1
0.75 mm2
Vinyl cabtire cable (VCT) 2 conductors
600-V vinyl-insulated
sheath cable (VVF)
2 conductors 1 dia.,
3
1.2 dia.,
1.6 dia.
Note: Do not use wires containing silicone, otherwise a contact failure
4
may result.
2
5
6
Small Limit Switch D4V
Mounting
1. Front Surface Mounting
2. Rear Surface Mounting
1. Through-hole Panel Mounting
Mounting Hole Diagram
Four, 5.5 dia. holes
M5 mounting
bolt
Mounting Hole Diagram
Four, 4.5 dia. holes
M4 mounting nut
56±0.3
M4 mounting bolt
56±0.3
21±0.3
21±0.3
Spring washer
All units are in millimeters
unless otherwise indicated.
Spring washer
All units are in millimeters
unless otherwise indicated.
Note: The tap screws for the body are M5, P=0.8, with a minimum
depth of 7.5 mm. Use bolts with a length of the panel thickness
t + 7 mm or less.
2. Tap Panel Mounting
Mounting Hole Diagram
Others
Four, M4 tapped holes
(P=0.7)
• Do not use the Limit Switch outdoors, otherwise the Limit Switch
M4 mounting bolt
Spring washer
will be damaged by rust or ozone.
56±0.2
• The Limit Switch is not suitable in places exposed to the spray of
rainwater, seawater, or oily water. Contact your OMRON
representative if such specifications are required.
21±0.2
All units are in millimeters
unless otherwise indicated.
• If high-sealing performance is required along with shielded wiring
or conduit wiring, use the D4C or WL.
Using the Switch
Changing the Actuator Mounting
Position
Changing the Head Direction
(D4V-8104Z, D4V-8107Z, D4V-8108Z)
By loosening one screw (black) at a time, the head can be changed
at 90° increments in any of the four directions.
(D4V-8104Z, D4V-8108Z, D4V-8107Z)
By loosening the Allen-head bolt on the actuator lever, the position of
the actuator can be set anywhere within the 360°.
Rotation screw
(black)
Operation
• Operate the coil spring and wire spring models between the tip of
the actuator and 1/3 the length of the actuator and parallel to the
direction of operation.
Loosen the
Allen-head
bold.
• Handling the bottom of the actuator or excessively pushing in the
tip may lead to bending damage, deformation, malfunction, and
deterioration of service life.
• Contact bouncing, chattering, or telegraphing may occur.
Take steps so that incorrect signals are not detected on the circuit
side if doing so will cause problems with the application.
Note: Telegraphing refers to the phenomenon of the actuator being
used and bouncing back after the operating body has passed,
and moving to the operation point on the opposite side, which
causes the contact to operate.
Small Limit Switch D4V
7
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C139-E1-01
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022/Fax: (81)75-344-7107
Printed in Japan
0306-2M (0306) (O)