D6F-P0010AM2 [OMRON]
MEMS Mass Flow Sensor; MEMS质量流量传感器型号: | D6F-P0010AM2 |
厂家: | OMRON ELECTRONICS LLC |
描述: | MEMS Mass Flow Sensor |
文件: | 总6页 (文件大小:688K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MEMS Mass Flow Sensor
D6F-P
A Compact, High-performance Flow
Sensor with Dust Segregation Structure.
• Built in Dust Segregation System (DSS) with cyclone flow
structure, diverts particulates from sensor element.
• High resolution and repeatability, even at low flow rates.
• Barbed ports with connector or PCB terminals, or manifold
mount with connector versions.
• Built in voltage regulator, temperature compensation and
amplified output. Measure up to 200 LPM with a bypass setup.
• Alternative to differential pressure sensing.
• RoHS Compliant
Ordering Information
Description
Case
Calibration Gas Flow Range
(See note 1.)
Mounting
Method
Connection
Model
Flow Sensor
PBT
Air (See note 2.)
0-0.1 LPM
0-1 LPM
Flange mount
PCB terminals D6F-P0001A1
D6F-P0010A1
Connector
Manifold mount Connector
- - - - - -
D6F-P0010A2
D6F-P0010AM2
D6F-CABLE2
Cable Connector Assembly
- - -
- - -
- - -
Note: 1. Can be calibrated for different gas types. Consult your Omron representative.
2. Dry gas must not contain large particles, eg dust, oil, mist.
3. Cable Assembly “D6F-CABLE2”, used with D6F-P0010A2 and D6F-P0010AM2, is sold separately.
Specifications
■ Characteristics
Models
D6F-P0001A1
0 to 0.1 L/min.
Air
barbed fitting maximum outside dia. 4.9 mm
Lead terminal
D6F-P0010A1
0 to 1 L/min.
D6F-P0010A2
D6F-P0010AM2
Flow Range (See note 1.)
Calibration Gas (See note 2.)
Flow Port Type
manifold mount
Electrical Connection
Connector (3 wire)
Power Supply
4.75 to 9.45 VDC
Current Consumption
Operating Output Voltage
Output Voltage Limits (Min and Max.)
Accuracy and Temperature Characteristics
Repeatability (Reference (typical))
Case Material
Max. 15 mA (no load, Vcc = 5 VDC)
0.5 to 2.5 VDC
0 VDC min. and 3.1 VDC max. (Lead resistance 10 kΩ)
5% F.S. max. of detected characteristics at 25 C, within -10 to 60 °C (typical test results within ±2% F.S.)
±
°
± 1.0% F.S.
PBT
± 0.4% F.S.
Degree of Protection
IP40
Withstand Pressure
Pressure Drop (Reference (typical))
Operating Temperature
50 kPa (7 psi)
0.19 kPa
0.48 kPa
-10 to 60°C (1 LPM versions) and -33 to 75°C (0.1 LPM version) with no icing or condensation
(Storage: -40 to 80°C with no icing or condensation)
Operating Humidity
Insulation Resistance
Dielectric Strength
35 to 85% RH with no icing or condensation (Storage: 35 to 85% RH with no icing or condensation)
20 MΩ (500 VDC between lead terminal and the case)
500 VAC, 50/60 Hz for 1 minute. (Leakage current typ. Max. 1mA) between lead terminals and case.
Weight
8.5 g
8.0 g
Response Time (Reference (typical))
150 msec
Note: 1. Mass flow converted into volumetric flow rate, SLM (standard liters per minute) at 0°C, 1 atmosphere.
2. Dry gas. (must not contain large particles, dust, oil, mist)
MEMS Mass Flow Sensor D6F-P
7
■ Absolute Maximum Rating
Item
Power supply voltage
Output voltage
Symbol
Rating
10
Unit
VDC
VDC
Vcc
Vout
4.0
■ Output Voltage Characteristics
D6F-P0001A@
D6F-P0010A@
3.0
2.5
2.0
1.5
1.0
0.5
0.0
3.0
2.5
2.0
1.5
1.0
0.5
0.0
0
0
0.02
0.04
0.06
0.08
0.10
0.25
0.5
0.75
1
Flow Rate (L/min)
Flow Rate (L/min)
D6F-P0001A@
Flow Rate (LPM)
0.00
0.02
0.04
0.06
1.70 ± 0.10
0.08
2.10 ± 0.10
0.10
Output Voltage (VDC)
0.50 ± 0.10
0.90 ± 0.10
1.30 ± 0.10
2.50 ± 0.10
D6F-P0010A@
Flow Rate (LPM)
0.00
0.25
1.60 ± 0.10
0.50
2.10 ± 0.10
0.75
2.31 ± 0.10
1.00
Output Voltage (VDC)
0.50 ± 0.10
2.50 ± 0.10
Note: 1. Mass flow converted into volumetric flow rate, SLM (standard liters per minute) at 0°C, 1 atmosphere.
2. 0 to 0.5 VDC output indicates a negative flow direction.
3. Measurement condition: Power supply voltage 5 ± 0.1VDC, ambient temperature 25 ± 5 °C and ambient humidity 25 to 75% RH.
■ Repeatability. (Typical test results)
(5 Samples, D6F-P0010A@, repeated 10 times each)
1.0
0.8
0.6
0.4
0.2
0.0
-0.2
-0.4
-0.6
-0.8
-1.0
0.0
0.3
0.5
0.8
1.0
Flow Rate(lpm)
8
MEMS Mass Flow Sensor D6F-P
Dimensions
Note: All units are in millimeters unless otherwise indicated.
PCB terminals with Flange Mount
D6F-P0001A1 / D6F-P0010A1
Label: Gives model and lot numbers.
23.3
11.7
7.3
2.6 dia.
Two, 4.9 dia.
10
Two, 1.1 dia.
Two 3-dia.
through holes
XG8V-0344
13.5
4.76
2.54
Connector
0.2
14
7.6
Label
27.2
Three lands,
Dia.: 1.3
Made by OMRON
16.2
7.2
6
GND
Vcc
Three through holes
Dia.: 0.8
2.54
1.7
1.2
6
17.2
9.8
A
5.08
Vout
5.08
Detailed View of A
Recommended Dimensions
for Connector Mounting Holes
13.5
1.5
Two, R1.4
2.8 dia.
7.2
13.2
4.76
Connector with Flange Mount
D6F-P0010A2
7.3
Label: Gives model
and lot numbers.
11.7
Two, 4.9 dia.
Two, 1.1 dia.
23.3
10
2.6 dia.
Label
14
0.2
7.6
27.2
8.5
A
16.2
6
Note: 1. Use M3 or M2.6 pan screw or tapping screw
with an equal diameter for installation. And
bind tight with 0.59N·m or less torque.
1.2
8.5
1.7
13.5
1.5
17.2
3.Vcc
2.Vout
1.GND
2.8 dia.
Two, R: 1.4
13.2
2. Use an attached connector. Manufactured
by JST Mfg Co., Ltd. (Japan) for A2 and
AM2 types.
• Pressure welding connector
Socket: 03SR-3S
Detailed View of A
Wire: AWG#30
Connector with Manifold Mount
• Crimp type connector
Contact: SSH-003T-P0.2|
Wire: AWG#32 to #28
• Housing: SHR-03V-S
D6F-P0010AM2
22
18
6.7
8
0.1
*1
2
0
Two, 4-0.05 dia.
B
3. O-rings are not attached. 4mm ID tube
recommended for D6F-P0010A1 and
D6F-P0010A2 types.
3.5 dia.
1+0.1
0
27.2
0.05
14
22
A
6.4 9.6
2-C0.3
1. GND
0.1
2.7
2. Vout
3. Vcc
0.1
0.3
0.1
0.3
Detailed View of A
Label
Detailed View of B
Antirotain groove
Connector
Applicable Cable for D6F-P0010A@2 (Optional - sold separately)
part number: D6F-CABLE2
White wire
Black wire
1. GND
2. Vout
Red wire
3. Vcc
15 3
180 10
(5)
MEMS Mass Flow Sensor D6F-P
9
Packaging
TYPE D6F-P
3
1
No.
1
2
Item
Sock liner
Tray (25pcs)
Box (100 pcs)
Material
CCNB
Polyethylene
CCNB
2
3
Display seal
Application Information and Examples
■ Bidirectional Dust Segregation System
The D6F-P series has a patented dust segregation design. The flow path incorporates dual centrifugal chambers, in which particulate matter follows
in the outer path, away from the MEMS sensor chip regardless of the flow direction. Note, standard products are calibrated for unidirectional flow,
as indicated in note 3 of the “Output Characteristics” table, above. Contact Omron for bidirectional calibration options.
sensing element
Bypass Setup
HVAC Application
When used in a bypass set-up, as illustrated below, the D6F-P mass
flow sensors can measure flow rates far beyond the 1 LPM in-line rat-
ing. The pressure differential required to pull airflow through the sen-
sor can be accomplished by installing a flow restrictor between the
two ports or through the use of a flow cross in large ducts, as shown
in the HVAC application.
The D6F-P mass flow sensor is ideal for damper control in variable
air volume systems, where low flow rates are difficult to measure with
differential pressure sensors.
Note: Be sure to read the precautions and information common to all D6F sensors, contained in the Technical User’s Guide, “D6F Technical Information”
for correct use.
10
MEMS Mass Flow Sensor D6F-P
MEMO
MEMS Mass Flow Sensor D6F-P
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
10/10
Specifications subject to change without notice
Printed in USA
Cat. No. X305-E-1
MEMS Mass Flow Sensor D6F-P
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明