Cylindrical Proximity Sensor  
E2EL  
A new series of easy--to--use models for  
standard-- and double--distance  
H Stainless steel and brass housing  
H Two housing length for each type  
H Pre--wired and Plug--in connector types  
H Short--circuit protection and reverse polarity  
protection  
Sensor 500 Ordering Information  
Note: The tables below contain part numbers for those Proximity Sensors involved in the Sensor 500 Program only. A complete listing  
of all E2EL part numbers can be found on the following pages.  
J CABLE TYPES  
Brass housing  
Item  
Part numbers  
Output  
Diameter  
Length  
Mounting  
Shielded  
Sensing  
Distance  
NPN/NO  
NPN/NC  
PNP/NO  
PNP/NC  
6.5  
M8  
30 mm  
32 mm  
30 mm  
32 mm  
41 mm  
1.5 mm  
E2EL-C1R5E1  
E2EL-C2ME1  
E2EL-X1R5E1  
E2EL-X2ME1  
E2EL-X2E1  
E2EL-X4ME1  
E2EL-X5E1  
E2EL-X8ME1  
E2EL-C1R5E2  
E2EL-C2ME2  
E2EL-X1R5E2  
E2EL-X2ME2  
E2EL-X2E2  
E2EL-C1R5F1  
E2EL-C2MF1  
E2EL-X1R5F1  
E2EL-X2MF1  
E2EL-X2F1  
E2EL-C1R5F2  
E2EL-C2MF2  
E2EL-X1R5F2  
E2EL-X2MF2  
E2EL-X2F2  
Non--shielded 2.0 mm  
Shielded 1.5 mm  
Non--shielded 2.0 mm  
Shielded 2.0 mm  
Non--shielded 4.0 mm  
Shielded 5.0 mm  
Non--shielded 8.0 mm  
M12  
M18  
E2EL-X4ME2  
E2EL-X5E2  
E2EL-X4MF1  
E2EL-X5F1  
E2EL-X4MF2  
E2EL-X5F2  
40 mm  
E2EL-X8ME2  
E2EL-X8MF1  
E2EL-X8MF2  
J PLUG TYPES  
Brass housing  
Item  
Part numbers  
Output  
Diameter/  
Connection  
Length  
Mounting  
Shielded  
Sensing  
Distance  
NPN / NO  
NPN / NC  
PNP / NO  
PNP / NC  
6.5/Plug 45 mm  
1.5 mm  
E2EL-C1R5E1-M3  
E2EL-C2ME1-M3  
E2EL-X1R5E1-M3  
E2EL-X2ME1-M3  
E2EL-X2E1-M1  
E2EL-X4ME1-M1  
E2EL-X5E1-M1  
E2EL-X8ME1-M1  
E2EL-C1R5E2-M3  
E2EL-C2ME2-M3  
E2EL-X1R5E2-M3  
E2EL-X2ME2-M3  
E2EL-X2E2-M1  
E2EL-X4ME2-M1  
E2EL-X5E2-M1  
E2EL-X8ME2-M1  
E2EL-C1R5F1-M3  
E2EL-C2MF1-M3  
E2EL-X1R5F1-M3  
E2EL-X2MF1-M3  
E2EL-X2F1-M1  
E2EL-X4MF1-M1  
E2EL-X5F1-M1  
E2EL-X8MF1-M1  
E2EL-C1R5F2-M3  
E2EL-C2MF2-M3  
E2EL-X1R5F2-M3  
E2EL-X2MF2-M3  
E2EL-X2F2-M1  
E2EL-X4MF2-M1  
E2EL-X5F2-M1  
E2EL-X8MF2-M1  
M8  
47 mm  
Non--shielded 2.0 mm  
Shielded 1.5 mm  
Non--shielded 2.0 mm  
Shielded 2.0 mm  
Non--shielded 4.0 mm  
Shielded 5.0 mm  
Non--shielded 8.0 mm  
M8/Plug  
M8  
45 mm  
47 mm  
49 mm  
M12/Plug  
M12  
M18/Plug  
M12  
53 mm  
E2EL  
E2EL  
Ordering Information  
Note: The tables below contain a complete listing of all E2EL part numbers. For information on Proximity Sensors involved in the Sensor 500  
Program refer to the previous page.  
J CABLE TYPES  
Brass housing  
Item  
Part numbers  
Output  
Diameter  
Length  
Mounting  
Shielded  
Sensing  
Distance  
NPN/NO  
NPN/NC  
PNP/NO  
PNP/NC  
6.5  
M8  
30 mm  
32 mm  
45 mm  
47 mm  
30 mm  
32 mm  
45 mm  
47 mm  
41 mm  
1.5 mm  
E2EL- C1R5E1  
E2EL- C2ME1  
E2EL- C1R5E2  
E2EL- C2ME2  
E2EL- C1R5F1  
E2EL- C2MF1  
E2EL- C1R5F2  
E2EL- C2MF2  
Non--shielded 2.0 mm  
Shielded 1.5 mm  
Non--shielded 2.0 mm  
Shielded 1.5 mm  
Non--shielded 2.0 mm  
Shielded 1.5 mm  
Non--shielded 2.0 mm  
E2EL- C1R5E1- L E2EL- C1R5E2- L E2EL- C1R5F1- L E2EL- C1R5F2- L  
E2EL- C2ME1- L  
E2EL- X1R5E1  
E2EL- X2ME1  
E2EL- C2ME2- L  
E2EL- X1R5E2  
E2EL- X2ME2  
E2EL- C2MF1- L  
E2EL- X1R5F1  
E2EL- X2MF1  
E2EL- C2MF2- L  
E2EL- X1R5F2  
E2EL- X2MF2  
E2EL- X1R5E1- L E2EL- X1R5E2- L E2EL- X1R5F1- L E2EL- X1R5F2- L  
E2EL- X2ME1- L  
E2EL- X2E1  
E2EL- X2ME2- L  
E2EL- X2E2  
E2EL- X2MF1- L  
E2EL- X2F1  
E2EL- X2MF2- L  
E2EL- X2F2  
M12  
Shielded  
Shielded  
2.0 mm  
4.0 mm  
E2EL- X4E1- D  
E2EL- X4ME1  
E2EL- X2E1- L  
E2EL- X4E1- DL  
E2EL- X4ME1- L  
E2EL- X5E1  
E2EL- X4E2- D  
E2EL- X4ME2  
E2EL- X2E2- L  
E2EL- X4E2- DL  
E2EL- X4ME2- L  
E2EL- X5E2  
E2EL- X4F1- D  
E2EL- X4MF1  
E2EL- X2F1- L  
E2EL- X4F1- DL  
E2EL- X4MF1- L  
E2EL- X5F1  
E2EL- X4F2- D  
E2EL- X4MF2  
E2EL- X2F2- L  
E2EL- X4F2- DL  
E2EL- X4MF2- L  
E2EL- X5F2  
Non--shielded 4.0 mm  
53 mm  
40 mm  
73 mm  
Shielded  
Shielded  
2.0 mm  
4.0 mm  
Non--shielded 4.0 mm  
M18  
M30  
Shielded  
Shielded  
5.0 mm  
8.0 mm  
E2EL- X8E1- D  
E2EL- X8ME1  
E2EL- X5E1- L  
E2EL- X8E1- DL  
E2EL- X8ME1- L  
E2EL- X10E1  
E2EL- X8E2- D  
E2EL- X8ME2  
E2EL- X5E2- L  
E2EL- X8E2- DL  
E2EL- X8ME2- L  
E2EL- X10E2  
E2EL- X8F1- D  
E2EL- X8MF1  
E2EL- X5F1- L  
E2EL- X8F1- DL  
E2EL- X8MF1- L  
E2EL- X10F1  
E2EL- X8F2- D  
E2EL- X8MF2  
E2EL- X5F2- L  
E2EL- X8F2- DL  
E2EL- X8MF2- L  
E2EL- X10F2  
Non--shielded 8.0 mm  
Shielded  
Shielded  
5.0 mm  
8.0 mm  
Non--shielded 8.0 mm  
Shielded 10.0 mm  
Non--shielded 15.0 mm  
Shielded 10.0 mm  
Non--shielded 15.0 mm  
40 mm  
80 mm  
E2EL- X15ME1  
E2EL- X10E1- L  
E2EL- X15ME2  
E2EL- X10E2- L  
E2EL- X15MF1  
E2EL- X10F1- L  
E2EL- X15MF2  
E2EL- X10F2- L  
E2EL- X15ME1- L E2EL- X15ME2- L E2EL- X15MF1- L E2EL- X15MF2- L  
Stainless steel housing  
Item  
Part numbers  
Diameter  
6.5  
M8  
Length  
Mounting  
Sensing  
Distance  
Output  
NPN/NO  
NPN/NC  
PNP/NO  
PNP/NC  
30 mm  
45 mm  
30 mm  
45 mm  
41 mm  
53 mm  
40 mm  
73 mm  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
Shielded  
2.0 mm  
2.0 mm  
2.0 mm  
2.0 mm  
4.0 mm  
4.0 mm  
8.0 mm  
8.0 mm  
E2EL- C2E1- DS  
E2EL-C2E1-DSL  
E2EL- X2E1- DS  
E2EL- C2E2- DS  
E2EL-C2E2-DSL  
E2EL- X2E2- DS  
E2EL- C2F1- DS  
E2EL- C2F2- DS  
E2EL- C2F1- DSL E2EL- C2F2- DSL  
E2EL- X2F1- DS E2EL- X2F2- DS  
E2EL- X2E1- DSL E2EL- X2E2- DSL E2EL- X2F1- DSL E2EL- X2F2- DSL  
E2EL- X4E1- DS E2EL- X4E2- DS E2EL- X4F1- DS E2EL- X4F2- DS  
E2EL- X4E1- DSL E2EL- X4E2- DSL E2EL- X4F1- DSL E2EL- X4F2- DSL  
E2EL- X8E1- DS E2EL- X8E2- DS E2EL- X8F1- DS E2EL- X8F2- DS  
E2EL- X8E1- DSL E2EL- X8E2- DSL E2EL- X8F1- DSL E2EL- X8F2- DSL  
M12  
M18  
2
E2EL  
E2EL  
J PLUG TYPES  
Brass housing  
Item  
Part numbers  
Output  
Diameter/  
Length Mounting  
Sensing  
Distance  
Connection  
NPN / NO  
NPN / NC  
PNP / NO  
PNP / NC  
6.5/Plug 45 mm Shielded  
1.5 mm E2EL-C1R5E1-M3  
E2EL-C1R5E2-M3  
E2EL-C2ME2-M3  
E2EL-C1R5E2-M3L  
E2EL-C2ME2-M3L  
E2EL-X1R5E2-M3  
E2EL-X2ME2-M3  
E2EL-X1R5E2-M3L  
E2EL-X2ME2-M3L  
E2EL-X1R5E2-M1  
E2EL-X2ME2-M1  
E2EL-X1R5E2-M1L  
E2EL-X2ME2-M1L  
E2EL-X2E2-M1  
E2EL-C1R5F1-M3  
E2EL-C2MF1-M3  
E2EL-C1R5F1-M3L  
E2EL-C2MF1-M3L  
E2EL-X1R5F1-M3  
E2EL-X2MF1-M3  
E2EL-X1R5F1-M3L  
E2EL-X2MF1-M3L  
E2EL-X1R5F1-M1  
E2EL-X2MF1-M1  
E2EL-X1R5F1-M1L  
E2EL-X2MF1-M1L  
E2EL-X2F1-M1  
E2EL-C1R5F2-M3  
E2EL-C2MF2-M3  
E2EL-C1R5F2-M3L  
E2EL-C2MF2-M3L  
E2EL-X1R5F2-M3  
E2EL-X2MF2-M3  
E2EL-X1R5F2-M3L  
E2EL-X2MF2-M3L  
E2EL-X1R5F2-M1  
E2EL-X2MF2-M1  
E2EL-X1R5F2-M1L  
E2EL-X2MF2-M1L  
E2EL-X2F2-M1  
M8  
47 mm Non--shielded 2.0 mm E2EL-C2ME1-M3  
54 mm Shielded 1.5 mm E2EL-C1R5E1-M3L  
56 mm Non--shielded 2.0 mm E2EL-C2ME1-M3L  
M8/Plug 45 mm Shielded  
1.5 mm E2EL-X1R5E1-M3  
M8  
47 mm Non--shielded 2.0 mm E2EL-X2ME1-M3  
54 mm Shielded  
1.5 mm E2EL-X1R5E1-M3L  
56 mm Non--shielded 2.0 mm E2EL-X2ME1-M3L  
M8/Plug 44 mm Shielded  
M12  
1.5 mm E2EL-X1R5E1-M1  
46 mm Non--shielded 2.0 mm E2EL-X2ME1-M1  
60 mm Shielded  
1.5 mm E2EL-X1R5E1-M1L  
62 mm Non--shielded 2.0 mm E2EL-X2ME1-M1L  
M12/Plug 49 mm Shielded  
M12  
2.0 mm E2EL-X2E1-M1  
4.0 mm E2EL-X4E1-DM1  
Shielded  
E2EL-X4E2-DM1  
E2EL-X4ME2-M1  
E2EL-X2E2-M1L  
E2EL-X4E2-DM1L  
E2EL-X4ME2-M1L  
E2EL-X5E2-M1  
E2EL-X4F1-DM1  
E2EL-X4MF1-M1  
E2EL-X2F1-M1L  
E2EL-X4F1-DM1L  
E2EL-X4MF1-M1L  
E2EL-X5F1-M1  
E2EL-X4F2-DM1  
E2EL-X4MF2-M1  
E2EL-X2F2-M1L  
E2EL-X4F2-DM1L  
E2EL-X4MF2-M1L  
E2EL-X5F2-M1  
Non--shielded 4.0 mm E2EL-X4ME1-M1  
60 mm Shielded  
Shielded  
2.0 mm E2EL-X2E1-M1L  
4.0 mm E2EL-X4E1-DM1L  
Non--shielded 4.0 mm E2EL-X4ME1-M1L  
M18/Plug 53 mm Shielded  
5.0 mm E2EL-X5E1-M1  
8.0 mm E2EL-X8E1-DM1  
M12  
Shielded  
E2EL-X8E2-DM1  
E2EL-X8ME2-M1  
E2EL-X5E2-M1L  
E2EL-X8E2-DM1L  
E2EL-X8ME2-M1L  
E2EL-X10E2-M1  
E2EL-X15ME2-M1  
E2EL-X10E2-M1L  
E2EL-X8F1-DM1  
E2EL-X8MF1-M1  
E2EL-X5F1-M1L  
E2EL-X8F1-DM1L  
E2EL-X8MF1-M1L  
E2EL-X10F1-M1  
E2EL-X15MF1-M1  
E2EL-X10F1-M1L  
E2EL-X8F2-DM1  
E2EL-X8MF2-M1  
E2EL-X5F2-M1L  
E2EL-X8F2-DM1L  
E2EL-X8MF2-M1L  
E2EL-X10F2-M1  
E2EL-X15MF2-M1  
E2EL-X10F2-M1L  
Non--shielded 8.0 mm E2EL-X8ME1-M1  
80 mm Shielded  
Shielded  
5.0 mm E2EL-X5E1-M1L  
8.0 mm E2EL-X8E1-DM1L  
Non--shielded 8.0 mm E2EL-X8ME1-M1L  
M30/Plug 55 mm Shielded  
10.0 mm E2EL-X10E1-M1  
M12  
Non--shielded 15.0 mm E2EL-X15ME1-M1  
80 mm Shielded  
10.0 mm E2EL-X10E1-M1L  
Non--shielded 15.0 mm E2EL-X15ME1-M1L  
E2EL-X15ME2-M1L E2EL-X15MF1-M1L E2EL-X15MF2-M1L  
Stainless steel housing  
Item  
Part numbers  
Output  
Diameter/  
Connection  
Length Mounting Sensing  
Distance  
NPN / NO  
NPN / NC  
PNP / NO  
PNP / NC  
M8/Plug 54  
Shielded 2.0 mm  
E2EL-X2E1-DM3SL  
E2EL-X2E2-DM3SL  
E2EL-X2F1-DM3SL  
E2EL-X2F2-DM3SL  
M8  
mm  
M12/Plug 49  
Shielded 4.0 mm  
Shielded 4.0 mm  
Shielded 8.0 mm  
Shielded 8.0 mm  
E2EL-X4E1-DM1S  
E2EL-X4E1-DM1SL  
E2EL-X8E1-DM1S  
E2EL-X8E1-DM1SL  
E2EL-X4E2-DM1S  
E2EL-X4E2-DM1SL  
E2EL-X8E2-DM1S  
E2EL-X8E2-DM1SL  
E2EL-X4F1-DM1S  
E2EL-X4F1-DM1SL  
E2EL-X8F1-DM1S  
E2EL-X8F1-DM1SL  
E2EL-X4F2-DM1S  
E2EL-X4F2-DM1SL  
E2EL-X8F2-DM1S  
E2EL-X8F2-DM1SL  
M12  
mm  
60  
mm  
M18/Plug 53  
M12 mm  
80  
mm  
3
E2EL  
E2EL  
Specifications  
J BRASS TYPE  
Type  
6.5  
M8  
M12  
M18  
M30  
Operating voltage  
Rated supply voltage  
Current consumption  
Sensing object  
10 to 35 VDC  
24 VDC  
max. 15 mA at 24 VDC  
Ferrous metals  
Mounting ((s)hielded,  
s
n
s
n
s
s
n
s
s
8.0  
n
s
n
15.0  
(n)on--shielded) (see note)  
Operating distance in mm  
1.5  
2.0  
1.5  
2.0  
2.0  
4.0  
4.0  
5.0  
8.0  
10.0  
Tolerance of operating distance  
±10%  
Standard target size in mm  
(L x W x H in mm, FE 37)  
6.5x6.5x1  
8x8x1  
12x12x1  
18x18x1 24x24x1  
30x30x1 45x45x1  
Differential travel  
1 % ... 15 % of operating distance  
5.0 5.0 2.0 0.6  
Max. response frequency in kHz  
1.0  
0.5  
0.3  
0.5  
0.25  
0.15  
Control output  
Type  
E2EL--... E1 type: NPN--NO  
E2 type: NPN--NC  
F1 type: PNP--NO  
F2 type: PNP--NC  
Max--Load  
200 mA  
Max--on--state  
Voltage drop  
2.5 VDC (at 200mA load current and with 2 m cable)  
Circuit protection  
Indicator  
Reverse polarity, output short--circuit  
Operating indicator (yellow LED)  
Operating: --25° to 70°C  
Ambient temperature  
Humidity  
35 to 95 % RH  
Influence of temperature  
Dielectric strength  
Electromagnetic compatibility EMC  
Vibration resistance  
Shock resistance  
± 10 % max. of Sn at 23°C in temperature range of --25° to 70°C  
1,500 VAC, 50/60 Hz for 1 min. between current carry parts and case  
EN 60947--5--2  
10 to 70 Hz, 1.5 mm double amplitude for 1 hour each in X, Y and Z directions  
300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions  
Enclosure rating  
IP 67 (EN 60947--1)  
2
Connection  
Pre--wired  
Connector  
2 m PVC--cable, 3 x 0.14 2 m PVC--cable, 3 x 0.25 mm  
2m PVC--cable, 3 x  
2
mm@  
0.5 mm  
M8 plug  
M8 plug  
M12 plug  
M12 plug  
Weight in g  
Pre--wired  
Connector  
long  
short  
long  
short  
45  
50  
48  
15  
13  
75  
70  
25  
20  
115  
100  
60  
260  
200  
155  
110  
43  
10  
8
50  
Material  
Case  
Brass  
PBTP  
Sensing face  
Note: For detailed mounting instruction please refer to Installation section.  
4
E2EL  
E2EL  
J STAINLESS STEEL TYPE  
Type  
6.5  
10 to 35 VDC  
24 VDC  
M8  
M12  
M18  
Operating voltage  
Rated supply voltage  
Current consumption  
Mounting (see note)  
Sensing object  
max. 15 mA at 24 VDC  
Shielded  
Ferrous metals  
2.0  
Operating distance in mm  
Tolerance of operating distance  
2.0  
4.0  
8.0  
±10%  
Standard target size  
(L x W x H in mm, FE 37)  
6.5x6.5x1  
8x8x1  
12x12x1  
24x24x1  
Differential travel  
1 % ... 15 % of operating distance  
4.0 4.0  
Max. response frequency in kHz  
0.6  
0.25  
Control output  
Type  
E2EL--... E1 type: NPN--NO  
E2 type: NPN--NC  
F1 type: PNP--NO  
F2 type: PNP--NC  
Max--Load  
200 mA  
Max--on--state  
Voltage drop  
2.5 VDC (at 200mA load current and with 2 m cable)  
Circuit protection  
Indicator  
Reverse polarity, output short--circuit  
Operating indicator (yellow LED)  
Operating: --25° to 70°C  
Ambient temperature  
Humidity  
35 to 95 % RH  
Influence of temperature  
Dielectric strength  
Electromagnetic compatibility EMC  
Vibration resistance  
Shock resistance  
± 10 % max. of Sn at 23°C in temperature range of --25° to 70°C  
1,500 VAC, 50/60 Hz for 1 min. between current carry parts and case  
EN 60947--5--2  
Destruction: 10 to 70 Hz, 1.5 mm double amplitude for 1 hour each in X, Y and Z directions  
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions  
Enclosure rating  
IP 67 (EN 60947--1)  
2 m PVC--cable, 3 x 0.14 mm@  
2
Connection  
Pre--wired  
Connector  
Pre--wired  
2 m PVC--cable, 3 x 0.25 mm  
M12 plug  
--  
M8 plug  
Weight in g  
long  
short  
long  
short  
45  
43  
--  
50  
48  
10  
--  
75  
70  
25  
20  
120  
105  
65  
Connector  
--  
55  
Material  
Case  
stainless steel 1.4305 / AISI 303  
PBTP  
Sensing face  
Note: For detailed mounting instruction please refer to Installation Section.  
5
E2EL  
E2EL  
Engineering Data  
J STANDARDIZED CHARACTERISTIC FOR LATERAL APPROACH  
axial aproach  
1.2  
1
standard target  
’switch-on’ curve  
switch-off’ curve  
0.8  
0.6  
lateral approach  
on  
off  
0.4  
0.2  
0
-1  
-0.8  
-0.6  
-0.4  
-0.2  
0
0.2  
0.4  
0.6  
0.8  
1
lateral distance related to radius of ’active surface’ (r/ract  
)
J OUTPUT CIRCUIT DIAGRAM AND TIMING CHART  
E2EL--XjEj  
NPN Output  
E2EL-XjFj  
PNP Output  
Brown 1  
Brown 1  
Load  
4.7 k  
Black 4 (or 2)  
Load  
Main  
circuit  
Main  
circuit  
Black 4 (or 2)  
Blue 3  
4.7 kΩ  
0 V  
Blue 3  
E2EL- XjEj  
NPN Output  
E2EL- XjFj  
PNP Output  
NC  
NO  
NC  
NO  
Yes  
No  
Sensing object  
Sensing object  
Yellow indicator  
Control output  
Yes  
No  
Lit  
Lit  
Not lit  
ON  
Yellow indicator  
Control output  
Not lit  
ON  
OFF  
OFF  
6
E2EL  
E2EL  
J PIN ARRANGEMENT AT CONNECTOR TYPES  
1. Connector M8 (viewed to plug pins)  
Output  
--  
+
2. Connector M12 (viewed to plug pins)  
NO  
NC  
2 Not  
Used  
1 (+)  
2 Output  
1 (+)  
4 Output  
4 Not Used  
3(--)  
3(--)  
Dimensions  
Note: 1. All units are in millimeters unless otherwise indicated.  
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Values in parentheses () are cumulative values  
and may exceed tolerance of ±0.4 mm.  
3. The square j in the models represents the output configuration. Refer to Ordering Information.  
Cable Types  
E2EL- C1jR5 2M, E2EL- C2j- DS  
E2EL- C2Mj  
E2EL- C2Mj- L  
E2EL- X2Mj  
E2EL- C1R5j- L 2M, E2EL- C2j- DSL  
E2EL- X1R5j 2M, E2EL- X2j- DS  
E2EL- X1R5j- L 2M, E2EL- X2j- DSL  
E2EL- X2Mj- L  
7
E2EL  
E2EL  
E2EL- X2j 2M, E2EL- X4j- D 2M, E2EL- X4j- DS  
E2EL- X4Mj  
E2EL- X2j- L 2M, E2EL- X4j- DL 2M, E2EL- X4j- DSL  
E2EL- X4Mj- L  
E2EL- X5j 2M, E2EL- X8j- D 2M, E2EL- X8j- DS  
E2EL- X5j- L 2M, E2EL- X8j- DL 2M, E2EL- X8j- DSL  
E2EL- X10j  
E2EL- X8Mj  
E2EL- X8Mj- L  
E2EL- X15Mj  
E2EL- X10j- L  
E2EL- X15Mj- L  
8
E2EL  
E2EL  
Plug Types  
E2EL- C1R5j- M3  
E2EL- C2Mj- M3  
E2EL- C1R5j- M3L  
E2EL- C2Mj- M3L  
E2EL- X1R5j- M3  
E2EL- X2Mj- M3  
E2EL- X1R5j- M3L, E2EL- X2jDM3S  
E2EL- X2Mj- M3L  
E2EL- X1R5j- M1  
E2EL- X2Mj- M1  
E2EL- X1R5j- M1L  
E2EL- X2Mj- M1L  
9
E2EL  
E2EL  
E2EL- X2j- M1, E2EL- X4j- DM1, E2EL- X4j- DM1S  
E2EL- X4Mj- M1  
E2EL- X2j- M1L, E2EL- X4j- DM1L, E2EL- X4j- DM1SL  
E2EL- X4Mj- M1L  
E2EL- X5j- M1, E2EL- X8j- DM1, E2EL- X8j- DM1S  
E2EL- X8Mj- M1  
E2EL- X5j- M1L, E2EL- X8j- DM1L, E2EL- X8j- DM1SL  
E2EL- X8Mj- M1L  
E2EL- X10j- M1  
E2EL- X15Mj- M1  
E2EL- X10j- M1L  
E2EL- X15Mj- M1L  
10  
E2EL  
E2EL  
Installation  
J CAUTION  
Item  
Examples  
Power Supply  
Do not impose an excessive voltage on the E2EL, otherwise it  
may explode or burn.  
Do not impose 24 VAC on any E2EL model, otherwise it may  
explode or burn.  
Load short--circuit  
Do not short--circuit the load, or the E2EL may explode or burn.  
The E2EL’s short--circuit protection function is valid, if the polarity  
of the supply voltage imposed is incorrect and within the rated  
voltage range.  
Wiring  
Be sure to wire the E2EL and load correctly, otherwise it may  
explode or burn.  
J CORRECT USE  
Core Tractive Force  
Installation  
Do not pull cords with the tractive force exceeding the following:  
pull force (N) = 20 x cable diameter ( mm)  
Mounting  
Power Reset Time  
The Proximity Sensor is ready to operate within 100 ms after  
power is supplied. If power supplies are connected to the  
Proximity Sensor and load respectively, be sure to supply power  
to the Proximity Sensor before supplying power to the load.  
The Proximity Sensor must not be subjected to excessive shock  
with a ha mmer when it is installed, otherwise the Proximity  
Sensor may be damaged or lose the water--resistivity.  
Power OFF  
The Proximity Sensor may output a pulse signal when it is turned  
off. Therefore, it is recommended to turn off the load before  
turning off the Proximity Sensor.  
Environment  
Water- Resistivity  
Power Supply Transformer  
Do not use the Proximity Sensor underwater, outdoors or in the  
rain.  
When using a DC power supply, make sure that the DC power  
supply has an insulated transformer. Do not use a DC power  
supply with an auto--transformer.  
Operating Environment  
Be sure to use the Proximity Sensor within operating ambient  
temperature range and do not use the Proximity Sensor outdoors  
so that its reliability and life expectancy can be maintained.  
Although the Proximity Sensor is water resistive, a cover to  
protect the Proximity Sensor from water or soluble machining oil  
is reco mmended so that its reliability and life expectancy can be  
maintained. Do not use the Proximity Sensor in an environment  
with chemical gas (e. G., strong alkaline or acid gases including  
nitric, chromic, and concentrated sulfuric acid gases).  
Sensing Object  
Metal Coating:  
The sensing distance of the Proximity Sensor vary with the metal  
coating on sensing objects.  
Wiring  
High- tension Lines  
Wiring through Metal Conduit  
If there a power or high--tension line near the cord of the  
Proximity Sensor, wire the cord through an independent metal  
conduit to prevent against Proximity Sensor damage or  
malfunctioning.  
11  
E2EL  
E2EL  
Item  
AND  
Examples  
Item  
The Sensors connected together must satisfy the  
following conditions:  
(serial  
connection)  
i + (N--1) x i = Upper--limit of control output of each  
L
Sensor  
V
S
-- N x V = Load operating voltage  
R
N =  
No. of Sensors  
V
V
=
=
Residual voltage of each Sensor  
Supply voltage  
R
S
i =  
Current consumption of the Sensor  
Load current  
i
=
L
If the MY Relay, which operate at 24 VDC, is used as a  
load for example, a maximum of two Proximity Sensors  
can be connected to the load.  
OR  
The number of Sensors connected in parallel varies with  
the Proximity Sensor model.  
(parallel  
connection)  
Effects of Surrounding Metal  
Shielded types  
Shielded types allow direct installation on metal plates in an embedded manner without performance change. A minimum distance of 3s  
is required between the active surface and a metallic surface in front of the device. (Fig. 1).  
n
For SUS shielded types the following minimum distances are required to avoid performance change (see Fig.2 and table below):  
Shielded SUS Types  
E2EL--C2j--DS  
Free zone  
0.5 mm  
0.5 mm  
1.0 mm  
2.0 mm  
E2EL--X2j--DS  
E2EL--X4j--DjS  
E2EL--X8j--DjS  
3sn  
Freezone  
3sn  
Fig.1: Shielded type (except SUS)  
Non-shielded types  
Fig.2: Shielded SUS type  
Installation of non--shielded types in metal require the minimum distances according to Fig. 3.  
3sn  
2sn  
d
3d  
Fig.3: Non- shielded type  
12  
E2EL  
E2EL  
13  
E2EL  
E2EL  
14  
E2EL  
E2EL  
15  
E2EL  
E2EL  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
R
OMRON ON--LINE  
OMRON ELECTRONICS LLC  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Global -- http://www.omron.com  
USA -- http://www.omron.com/oei  
Canada -- http://www.omron.com/oci  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. D093-E3-1  
05/01/2.5M  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

E2EL-X4F1-DS2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4F1-DSL

Cylindrical Proximity Sensor
OMRON

E2EL-X4F1-DSL2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-D

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-D2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DL

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DL2M

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1L

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1S

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DM1SL

Cylindrical Proximity Sensor
OMRON

E2EL-X4F2-DS

Cylindrical Proximity Sensor
OMRON