E2K-L26MC12M [OMRON]
Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid;型号: | E2K-L26MC12M |
厂家: | OMRON ELECTRONICS LLC |
描述: | Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid |
文件: | 总5页 (文件大小:361K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Liquid Level Sensor
E2K-L
CSM_E2K-L_DS_E_4_2
Liquid Level Sensor That Is
Unaffected by the Color of the Pipe or
Liquid
• Mount to bypass pipes.
• Fit a wide range of pipe diameters: 8 to 11 mm or 12 to 26 mm
• Built-in Amplifiers to save space.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 3.
Ordering Information
Sensors [Refer to Dimensions on page 4.]
Sensing method
Applicable pipe diameters
Appearance
Output configuration/Operation mode
Model
8 to 11 mm
E2K-L13MC1 2M
Capacitive
NPN open-collector output
NO
12 to 26 mm
E2K-L26MC1 2M
1
E2K-L
Ratings and Specifications
Item
Model
E2K-L13MC1
E2K-L26MC1
Materials
Size
Non-metal
8 to 11 mm
Diame-
ter
Applicable
pipes
12 to 26 mm
1.5 mm max.
Thick-
ness
1 mm max.
Detectable object
Repeat accuracy
Differential travel
Liquid *
0.2 mm max.
(Reference value, varies with pipe 0.6 to 5 mm
0.3 to 3 mm
size and liquid.)
Power supply voltage
(operating voltage range)
12 to 24 VDC (10.8 to 30 VDC), ripple (p-p): 10% max.
Current consumption
12 mA max.
Load current
100 mA max.
Control output
Residual voltage 1 V max. (Load current: 100 mA, Cable length: 2 m)
Sensing liquid position
Indicators
Indented mark position (For details, refer to Technical Guide (Operational version).)
Detection indicator (orange)
Ambient temperature range
Ambient humidity range
Operating: 0 to 55°C (with no icing or condensation), Storage: −10 to 65°C (with no icing or condensation)
Operating/Storage: 25% to 85% (with no condensation)
4 mm of detection level at 23°C in the temperature range of 0 to 55°C (with pure water or 20% saline
solution)
( 6 mm for E2K-L13MC1 with pure water and a pipe diameter of 8 mm)
Temperature influence
Voltage influence
0.5 mm of detection level at the rated voltage in rated voltage 10% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
IP66 (IEC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Pre-wired Models (Standard cable length: 2 m)
Approx. 70 g
Case, Cover
Materials
Heat-resistant ABS
Cable clamp
NBR
Accessories
Two bands, Four slip-proof tubes, Instruction manual
* Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application.
1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive
sensor.
2. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe
are too thick
3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall
Engineering Data (Reference Value)
Influence of Temperature and Sensing Liquid Level
E2K-L13MC1
E2K-L26MC1
6
6
Pipe diameter: 11, Liquid: Pure water
Pipe diameter: 26, Liquid: Pure water
Pipe diameter: 11, Liquid: Saline solution
Pipe diameter: 8, Liquid: Pure water
Pipe diameter: 8, Liquid: Saline solution
Pipe diameter: 26, Liquid: Saline solution
Pipe diameter: 12, Liquid: Pure water
Pipe diameter: 12, Liquid: Saline solution
4
2
4
2
10
20
0
10
0
0
-10
0
30
40
50 60
−10
20
30
40
50 60
Temperature (°C)
Temperature (°C)
−2
−2
−4
−4
−6
6
−
2
E2K-L
I/O Circuit Diagrams
Operation mode
Model
Timing chart
Output circuit
Brown
+V
Present
None
Load
Liquid level
Black
*
Main
circuit
E2K-L13MC1
E2K-L26MC1
Load (between brown
and black leads)
Operate
Reset
ON
NO
Detection indicator
(orange)
Blue
0 V
OFF
* Load current: 100 mA max.
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Mutual Interference
(Unit: mm)
Distance
Model
D *
E
F
E2K-L13MC1
E2K-L26MC1
25
30
10
10
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the
* Also, always adjust the bottom Sensor first because adjusting the bottom
Sensor may affect the detection level of the top Sensor.
ratings.
● Mounting
● Design
Mounting
Influence of Surrounding Objects
Mount the Sensor securely to the pipe using the enclosed two bands
and four slip-proof tubes (two tubes used for each band) as shown in
the following diagram.
When mounting the Sensor, be sure the entire Sensor is tight against
the pipe along the sensing surface.
When mounting the Sensor, maintain at least the distances in the
following diagrams from surrounding metal objects or other
conductors to prevent the Sensor from being affected by objects other
than the sensing object.
Pipe
Sensor
Pipe
Sensitivity
adjuster
Detection
indicator
Sensor
A
Face-to-face
B
Liquid level
Set
position
(indented
mark)
C
Bands
Slip-proof tubes
On One Side
On Both Sides
Side View
Front View
Influence of Surrounding Objects
(Unit: mm)
Distance
Pipe
Sensor
A
B
C
Model
E2K-L13MC1
E2K-L26MC1
5
0
45
40
25
Mutual Interference
When installing Sensors in series, in parallel, or face-to-face, ensure
that the minimum distances given in the following table are
maintained.
Bands
Slip-proof tubes
Top View
D
F
E
In Series
In Parallel
Face-to-face
3
E2K-L
● Wiring
● Operating Environment
Power Supply
Ambient Atmosphere
• If the load and Sensor are connected to different power supplies,
always turn ON the Sensor power first.
• Switching noise can cause operating mistakes if a commercial
switching regulator is used. When using a switching regulator,
always ground the frame ground terminal and the ground terminal.
• Although the Sensor is water resistance, it is a capacitive sensor
and should not be used where it will come into direct contact with
liquids, such as water or cutting oil.
• The life of the Sensor will be shorten by rapid changes in
temperature even within the ambient operating temperature range.
Do not use the Sensor in locations subject to rapid temperature
changes.
● Miscellaneous
Drift will occur when the power supply is turned ON. If the specific
inductive capacity of the sensing liquid is low, the detection level may
increase by 2 to 3 mm during the 20 minutes required from the time
the power supply is turned ON until operation stabilizes.
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E2K-L13MC1
20
5
R6.5
R17.5
24
11
Mounting holes
1.5
Detection
indicator
(orange)
6
43 41 33
4
4.5
5
1
Sensitivity
adjuster
Sensing surface
3.5
6
6.5
* 2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
E2K-L26MC1
20
5
R13
R17.5
Mounting holes
33
11
Sensitivity
adjuster
Detection
indicator
(orange)
6
4.5
1.5
2
34 32 24
3
1
Sensing surface
3.5
6.5
6
* 2.9-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.14 mm2,
Insulator diameter: 0.9 mm), Standard length: 2 m
4
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.