E2K-X15MY12M [OMRON]

Inductive Sensor, 13.5mm Min, 16.5mm Max, 200mA, Cylindrical;
E2K-X15MY12M
型号: E2K-X15MY12M
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Inductive Sensor, 13.5mm Min, 16.5mm Max, 200mA, Cylindrical

传感器 换能器
文件: 总7页 (文件大小:451K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Cylindrical Proximity Sensor  
E2K-X  
CSM_E2K-X_DS_E_3_1  
General-purpose Threaded Sensor  
That Detects Metals and Non-metals  
Alike  
• Detects both metallic and nonmetallic objects (water, oil, glass,  
plastic, etc.).  
• Three choices of threaded cylinder sizes for easy installation: M12,  
M18, and M30.  
• Fixed sensing distance requires no sensitivity adjustment.  
Be sure to read Safety Precautions on  
page 5.  
Ordering Information  
Sensors  
Model  
Operation mode  
Appearance  
Sensing distance  
Output configuration  
NO  
NC  
DC 3-wire, NPN  
AC 2-wire  
E2K-X4ME1 2M  
E2K-X4MY1 2M  
E2K-X8ME1 2M  
E2K-X8MY1 2M  
E2K-X15ME1 2M  
E2K-X15MY1 2M  
E2K-X4ME2 2M  
E2K-X4MY2 2M  
E2K-X8ME2 2M  
E2K-X8MY2 2M  
E2K-X15ME2 2M  
E2K-X15MY2 2M  
M12  
M18  
M30  
4 mm  
8 mm  
15 mm  
Unshielded  
DC 3-wire, NPN  
AC 2-wire  
DC 3-wire, NPN  
AC 2-wire  
Accessories (Order Separately)  
Mounting Brackets  
Refer to Y92@ for details.  
1
E2K-X  
Ratings and Specifications  
E2K-X4ME@,  
E2K-X4MY@  
E2K-X8ME@,  
E2K-X8MY@  
E2K-X15ME@,  
E2K-X15MY@  
Item  
Model  
Sensing distance  
Set distance *1  
4mm 10%  
8 mm 10%  
0 to 5.6 mm  
15 mm 10%  
0 to 10 mm  
0 to 2.8 mm  
Differential travel  
Detectable object  
4% to 20% of sensing distance  
Conductors and dielectrics  
Standard sensing object  
Response frequency  
Grounded metal plate: 50 × 50 × 1 mm  
E Models: 100 Hz, Y Models: 10 Hz  
E Models: 12 to 24 VDC (10 to 30 VDC)  
Power supply voltage*2  
(operating voltage range) Y Models: 100 to 220 VAC (90 to 250 VAC)  
Current consumption  
Leakage current  
E Models: 15 mA max.  
Y Models: 2.2 mA max. (Refer to page 4.)  
E Models: 200 mA max.*2, Y Models: 10 to 200 mA  
Load current  
Control  
output  
Residual voltage E Models: 1 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on page 4.  
Indicators  
E Models: Detection indicator (red), Y Models: Operation indicator (red)  
Operation mode  
(with sensing object  
approaching)  
E1/Y1 Models: NO  
E2/Y2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 4 for details.  
Protection circuits  
E Models: Reverse polarity protection, Surge suppressor, Y Models: Surge suppressor  
Ambient temperature  
range  
Operating/Storage: 10 to 55°C  
(with no icing or condensation)  
Operating/Storage: 25 to 70°C (with no icing or condensation)  
Ambient humidity range  
Temperature influence  
Operating/Storage: 35% to 95% (with no condensation)  
20% max. of sensing distance at 23°C in the operating temperature range  
E Models: 2% max. of sensing distance at rated voltage at rated voltage 20%  
Y Models: 2% max. of sensing distance at rated voltage at rated voltage 10%  
Voltage influence  
Insulation resistance  
Dielectric strength  
50 Mmin. (at 500 VDC) between current-carrying parts and case  
E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Vibration resistance  
Shock resistance  
Degree of protection  
Connection method  
Weight (packed state)  
Case  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 3 times each in X, Y, and Z directions  
IP66 (IEC), in-house standards: oil-resistant  
Pre-wired Models (Standard cable length: 2 m)  
Approx. 65 g  
Approx. 145 g  
Approx. 205 g  
Heat-resistant ABS  
Materi-  
Sensing surface  
als  
Clamping nuts  
Accessories  
Polyacetal  
Tightening tool, Instruction Manual  
Instruction manual  
*1. The above values are sensing distances for the standard sensing object. Refer to Engineering Data on page 3 for other materials.  
*2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC 20% (average value) can be used.  
2
E2K-X  
Engineering Data (Typical)  
Sensing Area (Grounded Metal Plate)  
E2K-X4M  
18  
16  
E2K-X15M  
14  
Y
X
12  
10  
Standard sensing  
object Grounded  
metal plate  
50 × 50 × 1 mm  
8
6
E2K-X8M  
E2K-X4M  
4
2
0
5 20 15 10 5  
0
5
10 15 20 25  
Distance  
E2K-X4M Sensing  
Y (mm)  
E2K-X8M Sensing Head  
E2K-X15M Sensing Head  
Influence of Sensing Object Size and Material  
E2K-X4M  
E2K-X8M  
E2K-X15M  
5
10  
25  
d ×  
d
d ×  
d ×  
d
d
t = 3 mm  
t = 3 mm  
t = 3 mm  
X
X
X
Grounded metal  
Grounded metal  
4
3
2
1
20  
8
Grounded metal  
6
15  
10  
5
Non-grounded metal  
Glass  
Non-grounded metal  
Non-grounded metal  
4
2
Glass  
Phenol  
Acryl  
Phenol  
Acryl  
Glass  
Phenol  
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Sensing Object Thickness and Material vs. Sensing Distance  
E2K-X4M  
E2K-X8M  
E2K-X15M  
10  
5
25  
50 ×  
50  
t
X
4
8
20  
Grounded metal  
Grounded metal  
50 ×  
50 ×  
50  
50  
t
t
X
X
Grounded metal  
3
2
1
6
4
2
15  
10  
5
Non-grounded metal  
Glass  
Non-grounded metal  
Non-grounded metal  
Glass  
Phenol  
Phenol  
Glass  
Acryl  
Phenol  
Acryl  
0
5
10  
15  
20  
25  
5
10  
15  
20  
25  
0
0
5
10  
15  
20  
25  
Thickness of sensing object: t (mm)  
Thickness of sensing object: t (mm)  
Thickness of sensing object: t (mm)  
3
E2K-X  
Leakage Current  
E2K-X@MY  
2.0  
Residual Output Voltage  
E2K-X@MY@  
at 100 VAC  
E2K-X@MY@  
at 200 VAC  
120  
240  
Residual output voltage  
100  
Residual output voltage  
200  
160  
120  
80  
ON  
ON  
1.5  
80  
Protective resistance  
mA  
V
V
AC  
60  
power,  
50/60Hz  
V
VL  
VL  
(OFF)  
200 VAC  
100 VAC  
1.0  
40  
A
A
20  
40  
0
Residual  
Load  
Voltage  
Residual  
Load Voltage  
OFF  
200  
Load current (mA)  
OFF  
0
3
0
100  
200  
300  
3
5
10  
20 30  
50  
100  
5
10  
20 30  
50  
100 200  
Power supply voltage (V)  
Load current (mA)  
I/O Circuit Diagrams  
DC 3-Wire Models  
Operation  
Model  
Timing chart  
Output circuit  
mode  
Present  
Sensing object  
Not present  
Load (between brown  
and black leads)  
Operate  
Reset  
High  
Brown  
E2K-X4ME1  
E2K-X8ME1  
E2K-X15ME1  
+V  
NO  
100 Ω  
4.7 kΩ  
Output voltage (between  
black and blue leads)  
Low  
Load  
Proximity  
Sensor  
main  
ON  
*1  
Black  
Detection indicator (red)  
OFF  
*2  
2.2 Ω  
Output  
circuit  
Tr  
Present  
Sensing object  
Blue  
Not present  
Operate  
Reset  
0 V  
Load (between brown  
and black leads)  
E2K-X4ME2  
E2K-X8ME2  
E2K-X15ME2  
*1. Load current: 200 mA max.  
NC  
High  
*2. When a transistor is connected.  
Output voltage (between  
black and blue leads)  
Low  
ON  
Detection indicator (red)  
OFF  
AC 2-Wire Models  
Operation  
Model  
Timing chart  
Output circuit  
mode  
Sensing object  
Load  
Present  
Not present  
Operate  
Reset  
E2K-X4MY1  
E2K-X8MY1  
E2K-X15MY1  
NO  
Brown  
Load  
ON  
Operation indicator (red)  
Proximity  
Sensor  
main  
OFF  
circuit  
Blue  
Present  
Not present  
Operate  
Reset  
Sensing object  
Load  
E2K-X4MY2  
E2K-X8MY2  
E2K-X15MY2  
NC  
ON  
Operation indicator (red)  
OFF  
4
E2K-X  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Sensing Objects  
The maximum sensing distance will decrease if the sensing object is  
a non-grounded metal object or dielectric object.  
Sensing Object Material  
The E2K-X can detect almost any type of object. The sensing  
distance of the E2K-X, however, will vary with the electrical  
characteristics of the object, such as the conductance and  
inductance of the object, and the water content and capacity of the  
object. The maximum sensing distance of the E2K-X will be  
obtained if the object is made of grounded metal.  
There are objects that cannot be detected indirectly. Therefore, be  
sure to test the E2K-X in a trial operation with the objects before  
using the E2K-X in actual applications.  
Precautions for Correct Use  
Do not use this product under ambient conditions that exceed the  
ratings.  
Design  
Ambient Environment  
The Sensor may malfunction if subjected to water, oil, chemicals, or  
condensation by falsely detecting these as sensing objects.  
The E2K-X15M is highly sensitive to inductive objects and can thus  
be affected even by small quantities of water drops.  
Effects of a High-frequency Electromagnetic Field  
The E2K-X may malfunction if there is an ultrasonic washer, high-  
frequency generator, transceiver, or inverter nearby.  
For major measures, refer to Noise of Warranty and Limitations of  
Liability for Photoelectric Sensors.  
Influence of Surrounding Objects  
If the Sensor is embedded in metal, maintain at least the following  
distances between the Sensor and the metal. The Sensor is also  
affected by other materials, such as resins. Separate the Sensor from  
other materials by the same distance as for metal.  
Mounting  
Do not tighten the nut with excessive force. Always use washers when  
tightening the nuts and do not exceed the torque in the following table.  
l
m
d dia.  
n
Model  
Torque  
*
Metal object  
Be sure to ground.  
E2K-X4M  
E2K-X8M  
E2K-X15M  
0.78 N·m  
* Be sure to ground the metal object, otherwise Sensor operation will not be  
stable.  
2 N·m  
Note: A special tightening tool is provided with the E2K-X4M@@. Always use  
Influence of Surrounding Metal (Unit: mm)  
this tool to tighten the nuts.  
Model  
Dimension  
l
d
m
8
n
E2K-X4M  
E2K-X8M  
E2K-X15M  
Miscellaneous  
20  
10  
50  
12  
25  
60  
Organic Solvents  
The Sensor has a case made of heat-resistant ABS resin. Be sure  
that the case is free from organic solvents or solutions containing  
organic solvents.  
If a mounting bracket is used, be sure that at least the following  
distances are maintained.  
Influence of Surrounding Metal  
(Unit: mm)  
G
Model  
Dimension  
G
H
E2K-X4M  
E2K-X8M  
20  
10  
30  
H
E2K-X15M  
Mutual Interference  
When installing Sensors face-to-face or side-by-side, ensure that the  
minimum distances given in the following table are maintained.  
B
A
Mutual Interference  
(Unit: mm)  
Model  
Dimension  
A
B
E2K-X4M  
E2K-X8M  
E2K-X15M  
80  
70  
150  
300  
110  
200  
5
E2K-X  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
E2K-X4ME@  
E2K-X4MY@  
E2K-X8ME@  
E2K-X8MY@  
80  
80  
4
29 dia.  
24  
21 dia.  
17  
60  
60  
4
20  
Indicator *2  
20  
Indicator *2  
4 4  
10.7 dia.  
16.6 dia.  
*1  
*1  
M12 × 1  
Two clamping nuts  
Two washers  
M18 × 1  
Two clamping nuts  
Two washers  
*1. E Models: 4-dia. vinyl-insulated round cable with 3 conductors  
(Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm),  
Standard length: 2 m  
Y Models: 4-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),  
Standard length: 2 m  
*1. E Models: 6-dia. vinyl-insulated round cable with 3 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
*2. E Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
*2. E Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
Mounting Hole Dimensions  
E2K-X15ME@  
E2K-X15MY@  
Model  
F (mm)  
+0.5  
0
E2K-X4ME@  
E2K-X4MY@  
E2K-X8ME@  
E2K-X8MY@  
E2K-X15ME@  
E2K-X15MY@  
12.5  
18.5  
30.5  
dia.  
dia.  
dia.  
+0.5  
0
F
+0.5  
0
80  
42 dia.  
36  
60  
10  
5
5
Indicator *2  
28.1 dia.  
*1  
M30 × 1.5  
Two clamping nuts  
Two washers  
*1. E Models: 6-dia. vinyl-insulated round cable with 3 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),  
Standard length: 2 m  
*2. E Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
6
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2008.11  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Right Reserved.  

相关型号:

E2K-X4ME1

Analog Circuit
OMRON

E2K-X4ME1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X4ME12M

Inductive Sensor, 3.6mm Min, 4.4mm Max, 200mA, Cylindrical
OMRON

E2K-X4ME2

Analog Circuit
OMRON

E2K-X4ME22M

Inductive Sensor, 3.6mm Min, 4.4mm Max, 200mA, Cylindrical
OMRON

E2K-X4MF1

Analog Circuit
OMRON

E2K-X4MF1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X4MF12M

Inductive Sensor, 0mm Min, 2.8mm Max, Cylindrical
OMRON

E2K-X4MF22M

Inductive Sensor, 0mm Min, 2.8mm Max, Cylindrical
OMRON

E2K-X4MY1-2M

General-purpose Threaded Capacitive Sensor
OMRON

E2K-X4MY12M

Inductive Sensor, 3.6mm Min, 4.4mm Max, 200mA, Cylindrical
OMRON

E2K-X4MY2

Analog Circuit
OMRON