E2S-Q13 [OMRON]

Analog Circuit;
E2S-Q13
型号: E2S-Q13
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Analog Circuit

文件: 总10页 (文件大小:210K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Subminiature Rectangular Inductive Prox  
E2S  
World’s Smallest Square Sensor with  
Built-in Amplifier  
H 5.5 x 5.5 mm type allows smaller,  
space-saving machines and devices  
H High response frequency (1 kHz) for fast  
machine processes  
H Long sensing distance:  
(E2S-j1, 1.6 mm) (E2S-j2, 2.5 mm)  
H Models with different oscillating  
frequency are available to reduce mutual  
interference  
Ordering Information  
JDC 2-WIRE  
Part number  
Operation status  
NO (Normally open) See Note.  
E2S--W11  
E2S--Q11  
E2S--W21  
Type  
Sensing surface  
Sensing distance  
NC (Normally closed)  
E2S--W12  
E2S--Q12  
E2S--W22  
E2S--Q22  
Front face  
End face  
Front face  
End face  
1.6 mm  
(0.06 in)  
Unshielded  
2 5 mm  
.
(0.10 in)  
E2S--Q21  
JDC 3-WIRE  
Part number  
Operation status  
NO (Normally open)  
See Note.  
Output  
configuration  
Type  
Sensing surface  
Sensing distance  
NC (Normally closed)  
Front face  
End face  
Front face  
End face  
Front face  
End face  
Front face  
End face  
E2S--W13  
E2S--Q13  
E2S--W23  
E2S--Q23  
E2S--W15  
E2S--Q15  
E2S--W25  
E2S--Q25  
E2S--W14  
E2S--Q14  
E2S--W24  
E2S--Q24  
E2S--W16  
E2S--Q16  
E2S--W26  
E2S--Q26  
1.6 mm  
(0.06 in)  
NPN  
PNP  
2.5 mm  
(0.10 in)  
Unshielded  
1.6 mm  
(0.06 in)  
2.5 mm  
(0.10 in)  
Note: Models with different oscillating frequency are available (NO only). These model numbers take the form of E2S--jjjB  
(e.g., E2S--W11B).  
2
E2S  
E2S  
JACCESSORIES  
Mounting Brackets  
Appearance  
Part number  
Y92E-C1R6  
Note  
Provided with E2S-j1jj  
Y92E-C2R5  
Provided with E2S-j2jj  
Y92E-D1R6  
Y92E-D2R5  
Optional bracket for E2S-j1jj  
Optional bracket for E2S-j2jj  
Specifications  
JRATINGS/CHARACTERISTICS  
DC 2-Wire Models  
Part number  
E2S--W11  
E2S--W12  
E2S--Q11  
E2S--Q12  
E2S--W21  
E2S--W22  
E2S--Q21  
E2S--Q22  
Sensor type  
Sensing surface  
Type  
Inductive  
Front face  
Unshielded  
End face  
Front face  
End face  
Power supply voltage  
(operating voltage range)  
12 to 24 V DC, ripple (p--p): 10% max., (10 to 30 V DC)  
Detectable object type  
Sensing distance  
Setting distance  
Ferrous metal (refer to Engineering Data for non-ferrous metals)  
1.6 mm ¦ 15% (0.06 in)  
0 to 1.2 mm (0.05 in)  
2.5 mm ¦ 15% (0.10 in)  
0 to 1.9 mm (0.07 in)  
Iron, 15 x 15 x 1 mm  
Standard target object  
Differential travel  
Operating status (with  
target object approaching)  
Iron, 12 x 12 x 1 mm  
10% max. of sensing distance  
jj1 models: NO  
jj2 models: NC Refer to Output Circuits and Timing Charts for details  
Control output  
Switching 3 to 50 mA DC max.  
capacity  
Residual 3.0 V max. with a load current of 50 mA and a cable length of 1 m  
voltage  
Leakage current  
0.8 mA max.  
Temperature influence  
¦ 15% max. of sensing distance at 23_C (73.4_F) in temperature range of --25_C to 70_C  
(--13_F to 158_F)  
Voltage influence  
¦ 2.5% max. of sensing distance in rated voltage range ¦ 10%  
Response frequency  
(See Note.)  
1 kHz min.  
Circuit protection  
Indicator  
Reverse polarity connection and surge absorber  
jj1 models: Operation indicator (red) Setting indicator (green)  
jj2 models: Operation indicator (red)  
Material  
Case  
Polyallylate resin  
Mounting  
Mounting bracket supplied  
Pre-wired standard length: 1 m (39.37 in)  
Approx. 10 g (0.35 oz)  
Connection method  
Weight (packed state)  
Enclosure rating  
IEC60529 IP67  
(This table continues on the next page.)  
3
E2S  
E2S  
Specifications Table -- continued from previous page  
Part number  
E2S--W11  
E2S--W12  
E2S--Q11  
E2S--Q12  
E2S--W21  
E2S--W22  
E2S--Q21  
E2S--Q22  
Ambient  
Operating -- 2 5 _C to 70_C (--13_F to 158_F) with no icing or condensation  
Storage -- 4 0 _C to 85_C (--40_F to 185_F) with no icing or condensation  
Operating 35% to 90% (with no condensation)  
Storage 35% to 95% (with no condensation)  
temperature  
Ambient humidity  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s@(1640 ft/s ) 3 times each in X, Y, and Z direction  
2
Insulation resistance  
Dielectric strength  
50 Mmin. (at 500 V DC) between current carry parts and case  
1,000 V AC, 50/60 Hz for 1 min between current carry parts and case  
Note: The response frequencies of the DC switching components are average values obtained by measuring in sequence a line-up of  
standard sensing objects. The space between any adjacent sensing objects was twice the width of a single sensing object and the  
setting distance was half the maximum sensing distance.  
DC 3-Wire Models  
Part number  
E2S--W13 E2S--Q13 E2S--W23 E2S--Q23 E2S--W15 E2S--Q15 E2S--W25 E2S--Q25  
E2S--W14 E2S--Q14 E2S--W24 E2S--Q24 E2S--W16 E2S--Q16 E2S--W26 E2S--Q26  
Sensor type  
Setting surface  
Type  
Inductive  
Front face End face  
Unshielded  
Front face End face  
Front face End face  
Front face End face  
Power supply voltage  
(operating voltage range)  
12 to 24 V DC, ripple (p--p): 10% max., (10 to 30 V DC)  
Current consumption  
Detectable object type  
Sensing distance  
13 mA max. at 24 VDC with no load  
Ferrous metal (refer to Engineering Data for non-ferrous metals)  
1.6 mm ¦ 15%  
0 to 1.2 mm  
2.5 mm ¦ 15%  
0 to 1.9 mm  
1.6 mm ¦ 15%  
0 to 1.2 mm  
2.5 mm ¦ 15%  
0 to 1.9 mm  
Setting distance  
Standard sensing object  
Differential travel  
Iron, 12 x 12 x 1 mm  
10% max. of sensing distance  
Iron, 15 x 15 x 1 mm  
Iron, 12 x 12 x 1 mm  
Iron, 15 x 15 x 1 mm  
Operating status (with  
jj3 models: NO  
jj3 models: NO  
jj4 models: NC  
sensing object approaching) jj4 models: NC  
Refer to Output Circuits and Timing Charts for  
details  
Refer to Output Circuits and Timing Charts for  
details  
Control output  
Control output  
Switching  
capacity  
NPN open collector output 50 mA max.  
(30 V DC max.)  
PNP open collector output 50 mA max.  
(30 V DC max.)  
Residual  
voltage  
1.0 V max. with a load current of 50 mA and a cable length of 1 m  
Temperature influence  
¦ 15% max. of sensing distance at 23_C (73.4_F) in temperature range of --25_C to 70_C  
(--13_F to 158_F)  
Voltage influence  
¦ 2.5% max. of sensing distance in rated voltage range ¦ 10%  
Response frequency (SeeNote.) 1 kHz min.  
Circuit protection  
Indicator  
Material  
Reverse polarity connection and surge absorber  
Operation indicator (orange)  
Polyallylate resin  
Case  
Mounting  
Mounting bracket supplied  
Connection method  
Pre-wired standard length: 1 m (39.37 in)  
Approx. 10 g (0.35 oz)  
IEC60529 IP67 [JEM IP67 (water-tight)]  
Weight (packed state)  
Degree of protection  
(This table continues on the next page.)  
4
E2S  
E2S  
Part number  
E2S--W13 E2S--Q13 E2S--W23 E2S--Q23 E2S--W15 E2S--Q15 E2S--W25 E2S--Q25  
E2S--W14 E2S--Q14 E2S--W24 E2S--Q24 E2S--W16 E2S--Q16 E2S--W26 E2S--Q26  
Ambient  
Operating  
Storage  
-- 2 5 _C to 70_C (--13_F to 158_F) with no icing or condensation  
-- 4 0 _C to 85_C (--40_F to 185_F) with no icing or condensation  
35% to 90%  
temperature  
Ambient humidity Operating  
Storage  
35% to 95% (with no condensation)  
Vibration resistance  
Shock resistance  
Destruction: 10 to 50 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions  
2
Destruction: 500 m/s@(1640 ft/sec ) 3 times each in X, Y, and Z direction  
Insulation resistance  
Dielectric strength  
50 Mmin. (at 500 V DC) between current carry parts and case  
1,000 V AC, 50/60 Hz for 1 min. between current carry parts and case  
Note: The response frequencies of the DC switching components are average values obtained by measuring in sequence a line-up of  
standard sensing objects. The space between any adjacent sensing objects was twice the width of a single sensing object and the  
setting distance was half the maximum sensing distance.  
Operation  
JOUTPUT CIRCUITS AND TIMING CHARTS  
DC 2-Wire Models  
Operation  
status  
Part number  
Timing charts  
Output circuits  
NO  
E2S--W11  
E2S--W21  
E2S--Q11  
E2S--Q22  
Setting position  
Unstable  
Sensing  
zone  
Non-sensing zone  
Stable  
sensing zone  
Proximity  
Sensor  
Sensing  
object  
0
100  
80  
(TYP)  
(%)  
Setting  
ON  
OFF  
Rated sensing  
distance  
indicator  
(green)  
brown  
Blue  
Operation  
indicator  
(red)  
Load  
ON  
OFF  
ON  
+V  
Main  
Control  
circuit  
output  
OFF  
Sensing zone  
Non-sensing zone  
NC  
E2S--W12  
E2S--W22  
E2S--Q12  
E2S--Q22  
Proximity  
Sensor  
0V  
The load can be connected both +V side and 0 V side  
Sensing  
object  
0
(%)  
100  
Rated sensing  
distance  
Operation  
ON  
OFF  
ON  
indicator  
(red)  
Control  
output  
OFF  
5
E2S  
E2S  
DC 3-Wire Models  
Operation  
status  
Output  
configuration  
Part number Timing charts  
Output circuits  
Yes  
No  
ON  
OFF  
ON  
NO  
NPN  
E2S--W13  
Target object  
E2S--W23  
brown  
+V  
E2S--Q13  
Output transistor(load)  
E2S--Q23  
Load  
Black  
(See note)  
Main  
OFF  
Output transistor(orange)  
Target object  
circuit  
Output  
Yes  
NC  
NO  
E2S--W14  
E2S--W24  
E2S--Q14  
E2S--Q24  
No  
Blue  
0V  
ON  
OFF  
ON  
OFF  
Output transistor(load)  
Output transistor(orange)  
Note: Maximum load current: 50 mA  
Yes  
No  
ON  
OFF  
ON  
OFF  
PNP  
E2S W15  
E2S--W25  
E2S--Q15  
E2S--Q25  
Target object  
brown  
+V  
Output transistor(load)  
Output transistor(orange)  
Black  
Main  
circuit  
(See note)  
0V  
Load  
Yes  
NC  
E2S--W16  
E2S--W26  
E2S--Q16  
E2S--Q26  
Target object  
No  
Blue  
ON  
OFF  
ON  
OFF  
Output transistor(load)  
Output transistor(orange)  
Note: Maximum load current: 50 mA  
Engineering Data  
JOPERATING RANGE (TYPICAL)  
E2S-W1j  
E2S-W2j  
E2S-Q1j  
E2S-Q2j  
4
4
Y
Y
X
X
3
2
3
2
1
0
1
0
-
3-  
-2  
-1  
0
1
2
3
4
4
- 4  
- 3  
- 2  
- 1  
0
1
2
3
4
Distance Y(mm)  
Distance Y(mm)  
E2S- Q1jSensing head  
E2S- Q2j Sensing head  
E2S- W1jSensing head  
E2S- W2jSensing head  
JSENSING OBJECT SIZE AND MATERIAL VS. SENSING DISTANCE (TYPICAL)  
E2S-W1j  
E2S-Q1j  
E2S-W2j  
E2S-Q2j  
4
2
d
Iron  
X
1.5  
3
SUS  
Iron  
SUS  
1
2
1
0
Brass  
Brass  
Copper  
Aluminum  
0.5  
Copper  
t=1mm  
X
Aluminum  
0
10  
20  
30  
40  
50  
10  
20  
30  
40  
50  
60  
Side length of target object d (mm)  
Side length of target object d (mm)  
6
E2S  
E2S  
Dimensions  
Unit: mm (inch)  
JE2S-W1j  
JE2S-Q1j  
With Mounting Bracket  
With Mounting Bracket  
3.2  
(0.13)  
3.2  
(0.13)  
R1  
R1  
2.6  
12.3 (0.48)  
3 (0.12)  
(0.10)  
Sensing  
surface  
3 (0.12)  
Sensing  
surface  
4.2 dia.  
R1.6  
R1.6  
R1.6  
5.5  
5.5  
(0.22)  
R1.6  
(0.22)  
Operation  
3.2  
4.2 dia.  
3.2  
(0.13)  
2.9 dia. Vinyl- insulated  
Operation  
(0.13)  
2.9 dia. Vinyl- insulated  
round cable, 2 / 3 cores  
3 (0.12)  
Indicator (orange)  
Indicator (orange)  
3 (0.12)  
round cable, 2 / 3 cores  
1
1
5
(conductor sectional area:  
5
(conductor sectional area:  
2
(0.20)  
7
2
0.14 mm , Insulator diameter:  
0.9 dia.); standard length: 1m  
0.14 mm , Insulator diameter:  
(0.20)  
7
0.9 dia.); standard length: 1m  
(0.28)  
(0.28)  
5
5
(0.20)  
(0.20)  
13.4 (0.53)  
14.9 (0.59)  
13.4 (0.53)  
14.9 (0.59)  
19 (0.75)  
1
1
19 (0.75)  
JE2S-W2j  
JE2S-Q2j  
With Mounting Bracket  
With Mounting Bracket  
3.2  
7.8  
(0.13)  
(0.31)  
3.2  
Four, R1  
R1.6  
R1  
(0.13)  
Operation Indicator (orange)  
1
Sensing surface  
7 dia.  
3.2  
Sensing surface  
(0.13)  
R1.6  
3.2  
(0.13)  
11.6  
(0.46)  
8
8
(0.31)  
(0.31)  
Two, R1.6  
R1.6  
8
8 (0.31)  
2.9 dia. Vinyl- insulated  
(0.31)  
2.9 dia. Vinyl- insulated  
round cable, 2 / 3 cores  
3.2  
10.1  
round cable, 2 / 3 cores  
Operation Indicator  
(orange)  
(0.13)  
(0.40)  
3.2  
(conductor sectional area:  
(conductor sectional area:  
2
(0.13)  
1
0.14 mm , Insulator diameter:  
3.2  
2
0.14 mm , Insulator diameter:  
0.9 dia.); standard length: 1m  
(0.13)  
0.9 dia.); standard length: 1m  
7.8  
3.2  
3.6  
(0.31)  
(0.12)  
(0.14)  
14.5 (0.57)  
3.3- dia. vinyl- insulated  
3.3- dia. mounting hole  
4.1  
20 (0.79)  
(0.16)  
3
11.5 (0.45)  
8
(0.12)  
(0.31)  
7.4  
(0.29)  
18.5 (0.73)  
23 (0.91)  
15.5 (0.61)  
3
(0.12)  
7
E2S  
E2S  
JMOUNTING BRACKET  
Y92E-C1R6  
Y92E-C2R5  
2.4-dia. screw depth 2 min.  
2.5  
2.5  
2
5.7  
0.4 (0.02)  
10.8 (0.43)  
Tow, R0.7  
17.5  
8.1  
2.3  
M3 screw  
dia. 2.4 screw  
depth 3 min.  
(0.32)  
(0.09)  
(0.69)  
depth 8 min.  
2.3  
(0.09)  
0.4  
3.1 dia. 11.3 (0.44)  
(
11.5 (0.45)  
2
2
0.4  
(0.02)  
Mounting Holes  
3
M3  
(0.12)  
Material: Stainless steel (SUS304)  
Mounting Holes  
Note: Provided with E2S-j2jj  
Material: Stainless steel (SUS304)  
Note: Provided with E2S-j1jj  
Y92E-E1R6  
Y92E-D2R5  
Two, R1.6  
22.4 (0.88)  
16 (0.63)  
Four, R1  
3.2  
3.2  
7.8  
5
7
1
3.2  
1
(0.31)  
(0.28)  
3
3
R1.6  
17.4 (0.69)  
Four, R1  
R1.6  
5
3.2  
Two, R1.6  
8
7
0.9  
(0.04)  
Two, M3  
5.6  
5.3  
Two, M3  
0.2  
(0.01)  
17 (0.67)  
0.3  
(0.28)  
(0.01)  
5
12  
(0.20)  
(0.47)  
Material: Stainless steel (SUS304) Mounting Holes  
Material: Stainless steel (SUS304)  
Mounting Holes  
8
E2S  
E2S  
Precautions  
JTO AVOID DAMAGE TO THE SENSOR JMUTUAL INTERFERENCE  
Do not impose any voltage exceeding the rated voltage on  
the Sensor. Do not impose AC voltage on models that oper-  
ate with DC.  
Be sure to space the two sensors at a distance greater then that  
shown in the table to prevent mutual interference.  
Do not short-circuit the load connected to the Sensor. Load  
short-circuit protection operates with correct power-supply  
and polarity in the rated voltage range.  
Front Surface Sensing Type  
A
B
The load must be connected to the Sensor in operation.  
When supplying power to the Sensor, make sure that the  
polarity of the power is correct.  
Make sure to connect a proper load to the Sensor in opera-  
tion, or it may be damaged.  
Do not use the Sensor in explosive or ignitable gas environ-  
ments.  
End Surface Sensing Type  
B
Do not disassemble, repair, or modify the product.  
A
JEFFECTS OF SURROUNDING METALS  
Unit: mm (inch)  
Provide a minimum distance as shown in the table below  
between the Sensor and the surrounding metal.  
Two Sensors with the Same Frequency  
Front Surface Sensing Type  
Model  
E2S-W(Q)1j  
E2S-W(Q)2j  
A
B
(Not Exceeding The Height of The Sensor Head)  
50 (1.97)  
75 (2.95)  
20 (0.79)  
25 (0.98)  
Sensing surface  
Sensing surface  
Proximity  
A
Two Sensors with Different Frequencies  
B
C
C
sensor  
Model  
A
B
E2S-W(Q)1j  
E2S-W(Q)2j  
40 (1.57)  
50 (1.97)  
55 (0.22)  
8 (0.31)  
Proximity sensor  
Model  
E2S--W1j  
A
0
B
C
Power Reset Time  
8 (0.31)  
2 (0.079)  
The Sensor is ready to detect objects in 100 ms after the Sensor  
is turned on. If the Sensor is connected to an independent power  
supply separately from the load, be sure to turn on the sensor  
first.  
E2S--W2j  
15 (0.59)  
10 (0.39)  
Top End Surface Sensing Type  
Power OFF  
A single pulse may output from the Sensor when the power  
supply is turned off. It is recommended that the load and load line  
are turned off first.  
B
A
B
Power Transformer  
Use only an insulated transformer for the DC power supply. Do  
not use an autotransformer (single-winding variable-voltage).  
C
Model  
E2S--Q1j  
A
B
C
2 (0.079)  
8 (0.31) 3 (0.12)  
JWIRING  
Separating from High-Tension Lines  
E2S--Q2j  
15 (0.59) 10 (0.39) 3 (0.12)  
Use Metal Conduit.  
If a standard switching regulator is used, be sure to ground the  
FG (frame ground) and G (ground) terminals to prevent Sensor  
malfunction due to the switching noise of the regulator.  
Pass cable through separate metal conduits to prevent  
malfunctioning and damage due to positioning proximity-sensor  
leads alongside power lines or motor lines. The same precaution  
applies to the DC type.  
Do not pull cables with tensile strength exceeding 30 N (6.7 lbf).  
9
E2S  
E2S  
JMOUNTING  
JENVIRONMENT  
Mounting Conditions  
Water Resistance  
Do not use the Sensor in water, in the rain, or outdoors.  
Do not stride the Sensor with a hammer or any other tool during  
the installation of the Sensor, or the Sensor will lose its  
water-resistant properties.  
To ensure stable operation and long sensor life, do not operate  
the sensor outside the rated temperature range or in outside  
conditions.  
Tightening Torque  
Although the proximity sensor has a water-resistant conditions,  
reliability and product life can be further enhanced by installing a  
cover to prevent water splashing directly on the sensor. Avoid  
operating the sensor in an atmosphere containing chemical  
reagents, strong alkalis, or acids (citric acid, chromic acid, hot  
concentrated sulfuric acid).  
Do not tighten the E2S-W(Q)j2 mounting screws to a torque  
exceeding 0.7 NSm (0.52 ft/lbf).  
JMAINTENANCE AND INSPECTION  
To ensure long-term stable operation, periodically subject the  
proximity sensor to the same checks as all other control  
instruments.  
Conduct the following checks.  
Check the mounting position of the sensor relative to the  
detected object. Check for displacement, looseness, and  
deformation.  
Check for looseness, defective contact, and discontinuities in  
the wiring and terminals.  
Check for attached or accumulated metal powder.  
Check for abnormal operating temperature and ambient tem-  
perature.  
If the sensor has a setting display lamp, check that the lamp  
operates correctly.  
Never disassemble or repair the sensor.  
10  
E2S  
E2S  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
R
OMRON ON--LINE  
OMRON ELECTRONICS LLC  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Global -- http://www.omron.com  
USA -- http://www.omron.com/oei  
Canada -- http://www.omron.com/oci  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. CEDSAX4  
11/01  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

E2S-Q131M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q13B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q14

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q141M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q14B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q15

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q151M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q15B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q16

Analog Circuit
OMRON

E2S-Q161M

Inductive Sensor, 1.6mm Min, 1.6mm Max, 50mA, Rectangular
OMRON

E2S-Q16B

Miniature Square Inductive Proximity Sensor
OMRON

E2S-Q21

Analog Circuit
OMRON