Digital Fiber Sensors
E3X-DA-S
An Extensive of Standard Functions
to Support the World's Highest Level of
Stable Detection.
• "GIGA RAY" Giga Power Lighting Element to create a wide variety
of value.
• Power turning to easily set the optimum light level.
• Active Thereshold Control (ATC) reduces incorrect operation due to
dust, oil, or other influences.
• Automatic Power Control (APC) is always enabled to stabilize
emitter power with high accuracy.
Ordering Information
Amplifier Units [Dimensions➜page 23]
Applicable wire-saving connector
(sold separately)
Model
Connecting
method
Type
Appearance
NPN output
PNP output
Type
Model
Pre-wired
(2 m)
E3X-DA21-S 2M
E3X-DA51-S 2M
---
---
Standard
models
Master
connector
E3X-CN21
E3X-CN22
Wire-saving
connector ✽
E3X-DA7-S
E3X-DA9-S
Slave
connector
Pre-wired
(2 m)
E3X-DA21R-S 2M
E3X-DA7R-S
E3X-DA51R-S 2M
E3X-DA9R-S
---
---
Ultra-long-term
APC models
Master
connector
E3X-CN21
E3X-CN22
Wire-saving
connector ✽
Slave
connector
Pre-wired
(2 m)
E3X-DA21F-S 2M
E3X-DA7F-S
E3X-DA51F-S 2M
E3X-DA9F-S
---
---
High-speed
response
models
Master
connector
E3X-CN11
E3X-CN12
Wire-saving
connector ✽
Slave
connector
✽ An Wire-saving connector sold separately is required.
1
E3X-DA-S
Wire-saving connector (sold separately) Protection stickers attached [Dimensions➜page 25]
Type
Appearance
Cable length
No. of conductors
Model
Master connector
4
E3X-CN21
Slave connector
Master connector
Slave connector
2
3
1
E3X-CN22
E3X-CN11
E3X-CN12
2 m
Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support
only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.
Accessories (sold separately)
Mounting Brackets [Dimensions➜page 26]
End Plate [Dimensions➜page 26]
Appearance Model
Appearance
Model
Quantity
Quantity
E39-L143
1
PFP-M
1
Product Overview
}: Strong point of the model {: Provided ---: Not provided
Types
Standard models
Ultra-long-term APC models
High-speed response models
Connecting
method
Wire-saving
connector
Wire-saving
Pre-wired
Wire-saving
Pre-wired
Pre-wired
connector
connector
E3X-DA21-S
E3X-DA51-S
E3X-DA7-S
E3X-DA9-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA7R-S
E3X-DA9R-S
E3X-DA21F-S
E3X-DA51F-S
E3X-DA7F-S
E3X-DA9F-S
Models
Item
External input
1 input
---
1 input
---
---
Input/output
Output
2 outputs
1 output and 1 APC alarm output
1 output
Sensing distance
with E32-T11R
280 to 2,000 mm
(Depends on response time)
140 to 1,000 mm
(Depends on response time)
280 mm
(Only Super-high-speed Mode)
Sensing distance
with E32-D11R
100 to 840 mm
(Depends on response time)
50 to 420 mm
(Depends on response time)
100 mm
(Only Super-high-speed Mode)
Performance
Giga Power
(GIGA RAY)
}
{
{
(Margin: × 160)
High-speed
response
{
(80 μs)
{
(80 μs)
}
(46 μs)
Power tuning
{
{
{
Automatic power
control (APC)
}
{
{
(Ultra-long-term APC)
Timer
ATC
{
{
{
{
{
{
{
{
{
Function
Key lock
Easy key lock
(switchable)
---
{
{
APC margin
display
---
---
{
---
Slow-motion display
---
{
2
E3X-DA-S
Ratings and Specifications
Amplifier Units
Type
Standard models
Ultra-long-term APC models
E3X-DA -S (@: 21/51/7/9)
High-speed response models
Item
Model
E3X-DA@-S (@: 21/51/7/9)
Red,4-element LED (625 nm)
@
R
E3X-DA@F-S (@: 21/51/7/9)
Light source
(wavelength)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Normal mode
: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
Power consumption
Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control output /
APC alarm output
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max.
External input ✽1
No-voltage input (contact / transistor) ✽2
---
Protection circuits
Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Super-high-
NPN output: Operate: 46
PNP output: Operate: 51
μ
s, Reset: 48
s, Reset: 53
μ
s
s
Operate or reset: 80 μs
Operate or reset: 250 μs
speed Mode ✽3
μ
μ
High-speed
Mode
Re-
sponse
time
Standard Mode Operate or reset: 1 ms
---
---
High-resolution
Operate or reset: 4 ms
Mode
Tough Mode
Sensitivity setting
Power tuning
Operate or reset: 16 ms
Teaching or manual method
Light emission power and reception gain, digital control method
Switchable between Single-edge and Double-edge Detection Modes.
Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms.
Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms
Differential
detection
Automatic
power control
(APC)
Always enabled.
High-speed control of emission current
Wide-range APC for the E3X-DA
@R-S
Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer
Timer
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1-s increments)
ATC
Provided
APC margin
display
---
---
Provided
---
Func-
tions
Slow-motion
display
Provided
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting
settings
Select from initial reset (factory defaults) or user reset (saved settings).
Mutual
interference
prevention
Possible for up to 10 units ✽4
---
ECO Mode ✽5
Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF).
External input
setting ✽1
Select from teaching operations, power tuning, zero reset, emitter OFF, or
ATC start.
---
Select from output for each channel,
---
Output setting
area output, or self-diagnosis.
Operation indicator for
Operation indicator for
channel 1(orange)
APC alarm output indicator (orange) Power tuning indicator (orange)
Operation indicator for
channel 1(orange)
channel 1(orange)
Operation indicator for
channel 2(orange)
Indicator
✽1. Only for Pre-wired models.
✽2. The following details apply to inputs.
Contact input (relay or switch)
Non-contact input (transistor)
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
NPN
PNP
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
✽3. The communications function and mutual interference prevention function are disabled if detection is set to Super-high-speed mode.
✽4. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units
and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units.
✽5. For the E3X-DA@-S (@: 21/51/7/9), the rated sensing distance is approximately 1/2 and the incident level is approximately 1/3 of the normal
levels when ECO mode is enabled.
3
E3X-DA-S
Item
Model
E3X-DA@-S (@: 21/51/7/9)
E3X-DA@R-S (@: 21/51/7/9)
E3X-DA@F-S (@: 21/51/7/9)
Digital display
Display orientation
Key lock
Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 17.)
Switching between normal / reversed display is possible.
Key lock
Key lock / Easy key lock.
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Maximum connectable
Units
16 (The ambient temperature specification depends on the number of connected units.)
Operating: Groups of 1 to 2 Amplifiers: −25 to 55°C
Groups of 3 to 10 Amplifiers: −25 to 50°C
Groups of 11 to 16 Amplifiers: −25 to 45°C
Ambient temperature
range
Storage: −30 to 70°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
20 MΩ min. (at 500 VDC)
1,000 VAC at 50/60 Hz for 1 minute
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Destruction: 500 m/s2 for 3 times each in X, Y and Z directions
IEC 60529 IP50 (with Protective Cover attached)
Pre-wired (standard length 2 m) or Wire-saving connector
Pre-wired models: Approx. 100 g, Wire-saving connector models: Approx. 55 g
Polybutylene terephthalate (PBT)
Degree of protection
Connection method
Weight (packed state)
Case
Materials
Cover
Polycarbonate (PC)
Accessories
Instruction Manual
Wire-saving connectors
Item
Model
E3X-CN21/22/11
E3X-CN12
Rated current
Rated voltage
2.5 A
50 V
20 mΩ max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor
resistance of the cable.)
Contact resistance
No. of insertions
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.)
Housing
Contacts
Polybutylene terephthalate (PBT)
Materials
Phosphor bronze / gold-plated nickel
Weight (packed state)
Approx. 55 g
Approx. 25 g
4
E3X-DA-S
Sensing Distance
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Screw-shaped model
Sensing distance (unit: mm)
Sensing
Size
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T21R 2M
Tough mode
method
mode
speed mode
M3
Straight
450
2,000
2,000
2,800
4,000 ✽
110
300
1,400
1,400
2,000
3,400
80
250
150
700
700
60
Right angle
E32-T11N 2M
E32-T11R 2M
E32-TC200 2M
E32-T11L 2M
E32-C31N 2M
E32-D21R 2M
E32-C31 2M
1,000
1,000
1,550
2,700
50
280
280
400
700
14
Through-
beam
models
M4
Straight
Right angle
Straight
1,000
1,740
46
M3
M4
140
100
60
40
16
330
240
150
60
100
40
44
E32-D211R 2M
E32-D11N 2M
E32-C11N 2M
E32-D11R 2M
E32-DC200 2M
E32-CC200 2M
E32-D11L 2M
140
100
16
840
600
350
350
350
600
600
800
240
320
240
400
400
520
100
100
100
180
180
220
Reflective
models
Right angle
Straight
780
560
840
600
M6
1,400
1,400
1,820
1,000
1,000
1,300
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Flat model
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
E32-T15XR 2M
Tough mode
mode
speed mode
Standard
Small
2,000
450
750
170
750
170
840
140
200
40
1,400
300
550
120
550
120
600
100
140
28
1,000
700
150
260
50
280
60
100
20
100
20
100
16
24
4
Top view
Side view
Flat view
Top view
Side view
Flat view
E32-T25XR 2M
E32-T15YR 2M
E32-T25YR 2M
E32-T15ZR 2M
E32-T25ZR 2M
E32-D15XR 2M
E32-D25XR 2M
E32-D15YR 2M
E32-D25YR 2M
E32-D15ZR 2M
E32-D25ZR 2M
250
450
100
450
100
350
60
Through-
beam
models
Standard
Small
Standard
Small
260
50
Standard
Small
240
40
Standard
Small
100
16
52
Reflective
models
10
Standard
Small
200
40
140
28
100
16
52
24
4
10
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Cylindrical model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
Tough mode
mode
speed mode
φ1
φ3
E32-T223R 2M
E32-T12R 2M
E32-T24R 2M
E32-T14LR 2M
E32-D22B 2M
E32-D32 2M
450
2,000
170
750
140
330
140
700
70
300
1,400
120
550
100
240
100
500
52
250
150
700
50
60
280
20
Top view
Through-
beam
models
1,000
100
450
60
φ1
Side view
Top view
Side view
φ3
260
40
100
16
44
φ1.5
φ2
150
60
100
40
E32-D22R 2M
E32-D32L 2M
E32-D24R 2M
E32-D14LR 2M
16
90
8
Reflective
models
φ3
300
30
200
20
φ2
φ6
220
160
100
60
28
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Model equipped with sleeve
Sensing distance (unit: mm)
Sensing
High-resolution
mode
Standard
mode
High-speed Super-high-
Sleeve size
method
Mounting size
Model
Tough mode
mode
speed mode
φ0.25 × 5
E32-T333-S5 1M
E32-T33 1M
35
150
450
2,000
14
25
110
300
1,400
10
20
12
50
8
20
60
280
2
φ3
Through-
beam
models
φ0.5 × 40
90
250
1,000
6
φ0.9 × 40
M3
M4
φ2
E32-TC200F4R 2M
E32-TC200BR 2M
E32-D331 2M
150
700
4
φ1.2 × 90
φ0.5 × 15
φ0.8 × 15
φ1.2 × 40
φ2.5 × 90
φ3
E32-D33 2M
70
50
30
20
8
Reflective
models
M3
M6
E32-DC200F4R 2M
E32-DC200BR 2M
140
840
100
600
60
40
16
100
350
240
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
5
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Movable section (Flexibility)
Sensing distance (unit: mm)
Sensing
Type
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
Tough mode
method
mode
speed mode
M3
M4
E32-T21 2M
E32-T11 2M
680
2,500
680
480
1,800
480
400
220
900
220
900
900
170
40
90
360
90
Screw-shaped
model
1,350
400
1,350
1,350
300
60
Through-
Cylindrical
beam
φ1.5
φ3
Standard
Small
M3
E32-T22B 2M
E32-T12B 2M
E32-T15XB 2M
E32-T25XB 2M
E32-D21 2M
model
2,500
2,500
500
1,800
1,800
360
360
360
70
models
Flat model
140
100
16
Screw-shaped
model
M4
E32-D21B 2M
E32-D11 2M
300
220
140
350
60
90
40
M6
840
600
240
40
100
16
Reflective
φ1.5
φ3
Standard
Small
E32-D22B 2M
E32-D221B 2M
E32-D15XB 2M
E32-D25XB 2M
140
100
Cylindrical
models
model
300
220
140
350
100
90
40
840
600
240
60
100
30
Flat model
240
170
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Heat-resistance model
Sensing distance (unit: mm)
Sensing
method
Operating
temperature
High-resolution
mode
Standard
mode
High-speed Super-high-
Lens
Model
E32-T51R 2M
E32-T51R 2M + E39-F1
Tough mode
mode
speed mode
---
1,600
4,000 ✽
4,000 ✽
2,800
4,000 ✽
4,000 ✽
840
1,100
4,000 ✽
4,000 ✽
2,000
4,000 ✽
4,000 ✽
600
800
560 225
100°C
150°C
Lens
4,000 ✽
4,000 ✽
1,500
4,000 ✽
4,000 ✽
450
3,900
4,000 ✽
1,000
2,300
4,000 ✽
300
1,500
4,000 ✽
400
High-power lens E32-T51R 2M + E39-F16
---
E32-T51 2M
Lens
E32-T51 2M + E39-F1-33
1,400
4,000 ✽
120
Through-
beam
models
High-power lens E32-T51 2M + E39-F16
E32-T54 2M
---
E32-T81R-S 2M
E32-T61-S 2M
1,000
1,680
4,000 ✽
1,680
4,000 ✽
670
720
550
360
140
200°C
350°C
1,200
4,000 ✽
1,200
4,000 ✽
480
900
4,000 ✽
600
240
Lens
---
E32-T61-S 2M + E39-F1
E32-T61-S 2M
4,000 ✽
1,800
240
900
600
High-power lens E32-T61-S 2M + E39-F16
E32-D51R 2M
4,000 ✽
280
4,000 ✽
190
3,100
80
100°C
150°C
200°C
350°C
400°C
E32-D51 2M
1,120
420
800
450
320
144
Reflective
models
---
E32-D81R 2M
E32-D61 2M
E32-D73 2M
300
180
120
54
420
300
180
120
54
280
200
120
80
36
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Chemical-resistance / Oil-resistance model
Sensing distance (unit: mm)
Sensing
Type
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T12F 2M
Tough mode
method
mode
4,000 ✽1
speed mode
φ5
φ7.2
φ5
4,000 ✽1
4,000 ✽1
4,000 ✽1
4,000 ✽1
4,000 ✽1
4,000 ✽1
1,600
E32-T11F 2M
2,600
1,000
E32-T51F 2M
4,000 ✽1
3,600
1,000
1,800
2,800
800
1,800
700
200
360
Heat-resistance model
Through-
beam
models
φ5
Side view
E32-T14F 2M
E32-T11U 2M
1,400
500
900
M4
2,500
1,350
Chemical-resistance cable
M4
E32-T11NU 2M
E32-D12F 2M
E32-D14F 2M
1,440
--- ✽2
--- ✽2
1,040
320
800
190
80
520
130
60
200
60
Right angle Chemical-resistance cable
φ6
φ7
Reflective
Side view
models
140
20
M6
E32-D11U 2M
840
600
350
240
100
Chemical-resistance cable
✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
✽2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Vacuum-resistance model
Sensing distance (unit: mm)
Sensing Operating ambient
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T51V 1M
Tough mode
method
temperature
120°C
mode
speed mode
720
3,780
580
520
2,700
420
400
260
100
520
70
Top view
Through-
beam
E32-T51V 1M + E39-F1V
E32-T54V 1M
2,000
250
1,360
200
models
Right angle
200°C
E32-T84SV 1M
1,760
1,250
950
640
260
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
6
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Long distance / Dust resistance (High-power),
Detection through gaps (Narrow vision field)
Sensing distance (unit: mm)
Sensing
method
Sensing direction /
Lens type
High-resolution
mode
Standard
mode
High-speed Super-high-
Type
Model
E32-T17L 10M
E32-T14 2M
E32-T11N 2M + E39-F1
Tough mode
mode
speed mode
8,000
1,800
2,000
3,600
2,000
3,600
200
Top view
Side view
High-power
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,450
4,000 ✽2
4,000 ✽2
2,350
4,000 ✽2
4,000 ✽2
2,300
4,000 ✽2
4,000 ✽2
2,300
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,000
4,000 ✽2
4,000 ✽2
1,680
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,040
4,000 ✽2
4,000 ✽2
1,680
4,000 ✽2
4,000 ✽2
1,640
4,000 ✽2
4,000 ✽2
1,640
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
720
4,000 ✽2
4,000 ✽2
1,200
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
800
4,000 ✽2
4,000 ✽2
1,400
4,000 ✽2
4,000 ✽2
1,320
4,000 ✽2
4,000 ✽2
1,320
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
550
4,000 ✽2
4,000 ✽2
900
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
500
High-power
(integrated unit)
Ultrahigh-power E32-T11N 2M + E39-F16
High-power E32-T11R 2M + E39-F1
Ultrahigh-power E32-T11R 2M + E39-F16
Side view
E32-T11R 2M + E39-F2
E32-TC200 2M + E39-F1
High-power
4,000 ✽2
4,000 ✽2
900
3,000
4,000 ✽2
320
Ultrahigh-power E32-TC200 2M + E39-F16
Side view
E32-TC200 2M + E39-F2
E32-T11 2M + E39-F1
High-power
4,000 ✽2
4,000 ✽2
860
1,860
4,000 ✽2
320
Ultrahigh-power E32-T11 2M + E39-F16
Through-
beam
models
Side view
E32-T11 2M + E39-F2
E32-T11U 2M + E39-F1
High-power
(with lens unit)
High-power
4,000 ✽2
4,000 ✽2
860
1,860
4,000 ✽2
320
Ultrahigh-power E32-T11U 2M + E39-F16
Side view
E32-T11U 2M + E39-F2
E32-T11NU 2M + E39-F1
High-power
2,600
4,000 ✽2
1,000
2,800
1,000
1,800
140
Ultrahigh-power E32-T11NU 2M + E39-F16
High-power E32-T81R-S 2M + E39-F1
Ultrahigh-power E32-T81R-S 2M + E39-F16
2,700
4,000 ✽2
360
Side view
E32-T81R-S 2M + E39-F2
E32-T61-S 2M + E39-F1
High-power
4,000 ✽2
4,000 ✽2
600
1,800
3,100
240
Ultrahigh-power E32-T61-S 2M + E39-F16
Side view
Top view
Side view
E32-T61-S 2M + E39-F2
E32-T22S 2M
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,800
2,500
1,000
700
Narrow vision field
(aperture angle: 4
°)
E32-T24S 2M
3,500
2,600
1,740
Reflective
models
High-power
Top view
E32-D16 2M
40 to 2,800
40 to 2,000
40 to 1,400
40 to 900
40 to 480
✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Minute object detection (Small-spot model)
Sensing distance (unit: mm)
Sensing Spot diameter
Focal length
(mm)
High-resolution
mode
Standard
mode
High-speed Super-high-
mode speed mode
Model
Tough mode
method
(mm)
φ
0.1 to 0.6
(Variable)
6 to 15
E32-C42 1M + E39-F3A
E32-C42 1M + E39-F17
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm
φ
0.3 to 1.6
10 to 30
(Variable)
5
7
E32-C42S 1M
Spot diameter of 0.1 mm at 5 mm
Spot diameter of 0.1 mm at 7 mm
Spot diameter of 0.2 mm at 17 mm
Spot diameter of 0.5 mm at 7 mm
Spot diameter of 0.5 mm at 17 mm
φ0.1
φ0.2
φ0.5
E32-C41 1M + E39-F3A-5
E32-C41 1M + E39-F3B
E32-C31 2M + E39-F3A-5
E32-C31 2M + E39-F3B
17
7
Reflective
models
17
Spot diameter of 6 mm at 50 mm
Sensing distance in all mode (40 to 100 mm)
φ6
50
E32-L15 2M
φ4
0 to 20
E32-C31 2M + E39-F3C
Spot diameter of 4 mm max. at 0 to 20 mm
Parallel light
E32-C11N 2M + E39-F18
E32-CC200 2M + E39-F18
Spot diameter of 3 mm at 50 mm
Spot diameter of 3 mm at 50 mm
φ3
50
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Area-sensing (Area beam)
Sensing distance (unit: mm)
Sensing
Area range
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T16PR 2M
Tough mode
mode
speed mode
Side view
Flat view
3,100
2,750
4,000 ✽
2,200
2,000
3,400
1,700
1,120
440
380
680
Through-
11 mm
beam
E32-T16JR 2M
E32-T16WR 2M
1,500
2,600
960
models
30 mm
11 mm
1,700
Side view
Reflective
models
E32-D36P1 2M
700
500
300
200
90
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
7
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection without background interference (Convergent-reflective)
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
E32-L16-N 2M ✽
E32-L24S 2M ✽
E32-L25L 2M ✽
E32-L24L 2M ✽
Tough mode
mode
speed mode
Standard
Small
0 to 15
0 to 12
Flat view
0 to 4
Reflective
models
Top view
Flat view
5.4 to 9 (center 7.2)
2 to 6 (center 4)
---
✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection of transparent objects (Retro-reflective)
Sensing distance (unit: mm)
Sensing
Type
High-resolution
Standard
mode
High-speed Super-high-
Model
Tough mode
method
mode
mode
speed mode
Square
Small
E32-R16 5M + E39-R1 (attached) ✽1
E32-R21 2M + E39-R3 (attached) ✽1
E32-C31 2M + E39-F3R+E39-RP37 ✽1
E32-C31 2M + E39-F3R+E39-RSP1 ✽1
150 to 1,500
10 to 250
Retrore-
flective
models
250
450
200
300
---
Film detection ✽2
100
✽1. When using a highly reflective object, light reflected from the object may affect the sensor.
✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens
Unit. Be sure to check operation in advance.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
FPD / Semiconductor / Solar battery industry
Sensing distance (unit: mm)
Sensing
method
Operating
temperature
High-resolution
mode
Standard
mode
High-speed Super-high-
Application
Model
E32-L16-N 2M ✽
E32-L16-N 2M ✽
E32-A08 2M ✽
E32-A08H2 3M ✽
E32-A09 2M
Tough mode
mode
speed mode
Glass detection
0 to 15
0 to 12
0 to 12
---
70°C
0 to 15
10 to 20
10 to 20
15 to 38
15 to 38
20 to 30
Glass substrate
alignment
300°C
70°C
---
---
Reflective
models
Glass substrate
mapping
150°C
300°C
60°C
E32-A09H 2M
E32-A09H2 2M
E32-L11FP 5M
E32-L12FS 5M
E32-L11FS 5M
E32-A03 2M
---
---
8 to 20 mm from end of lens (recommended: 11 mm)
8 to 20 mm from end of lens (recommended: 11 mm)
8 to 20 mm from end of lens (recommended: 11 mm)
WET process
70°C
85°C
3,220
3,220
1,280
1,280
2,300
2,300
920
1,780
1,780
680
1,200
1,200
450
500
500
200
200
Through-
beam
models
E32-A03-1 2M
E32-A04 2M
Wafer mapping
70°C
E32-A04-1 2M
920
680
450
✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Liquid-level detection model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
mode speed mode
Pipe diameter
No limit
Model
E32-D36T 5M ✽1, ✽2
E32-L25T 2M
Tough mode
Applicable pipe: Transparent (no restriction on diameter)
Mounted to pipe
Wet
Reflective
models
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,
recommended pipe wall thickness: 1 mm
φ8 to 10 mm
---
E32-D82F1 4M ✽1
Wet model
✽1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
✽2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
8
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Screw-shaped model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
E32-T21R 2M
Tough mode
mode
speed mode
M3
Straight
220
1,000
1,000
1,400
2,000
55
160
700
700
1,000
1,700
40
130
75
350
350
500
870
23
30
140
140
200
350
7
Right angle
E32-T11N 2M
E32-T11R 2M
E32-TC200 2M
E32-T11L 2M
E32-C31N 2M
E32-D21R 2M
E32-C31 2M
500
530
760
1,350
25
Through-
beam
models
M4
Straight
Right angle
Straight
M3
M4
70
50
30
20
8
165
70
120
50
75
50
22
E32-D211R 2M
E32-D11N 2M
E32-C11N 2M
E32-D11R 2M
E32-DC200 2M
E32-CC200 2M
E32-D11L 2M
30
20
8
420
390
420
700
700
910
300
280
300
500
500
650
175
175
170
300
300
400
120
160
120
200
200
260
50
50
50
90
90
110
Reflective
models
Right angle
Straight
M6
Fiber Unit
Flat model
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
Tough mode
mode
speed mode
Standard
Small
E32-T15XR 2M
E32-T25XR 2M
E32-T15YR 2M
E32-T25YR 2M
E32-T15ZR 2M
E32-T25ZR 2M
E32-D15XR 2M
E32-D25XR 2M
E32-D15YR 2M
E32-D25YR 2M
E32-D15ZR 2M
E32-D25ZR 2M
1,000
220
370
85
700
160
270
60
530
350
75
130
25
130
25
120
20
26
5
140
30
50
10
50
10
50
8
Top view
Side view
Flat view
Top view
Side view
Flat view
130
210
50
210
50
170
30
40
8
Through-
beam
models
Standard
Small
Standard
Small
370
85
270
60
Standard
Small
420
70
300
50
Standard
Small
100
20
70
12
2
Reflective
models
14
Standard
Small
100
20
70
40
8
26
5
12
2
14
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Cylindrical model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
Tough mode
mode
speed mode
φ1
φ3
E32-T223R 2M
E32-T12R 2M
E32-T24R 2M
E32-T14LR 2M
E32-D22B 2M
E32-D32 2M
220
1,000
85
160
700
60
130
75
350
25
30
140
10
50
8
Top view
Through-
beam
models
530
50
φ1
Side view
Top view
Side view
φ3
370
70
270
50
210
30
130
20
φ1.5
φ2
160
70
120
50
75
50
22
8
E32-D22R 2M
E32-D32L 2M
E32-D24R 2M
E32-D14LR 2M
30
20
Reflective
models
φ3
350
35
250
26
150
15
100
10
45
4
φ2
φ6
110
80
45
30
14
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Model equipped with sleeve
Sensing distance (unit: mm)
Sensing
High-resolution
mode
Standard
mode
High-speed Super-high-
Sleeve size
method
Mounting size
Model
Tough mode
mode
speed mode
φ0.25 × 5
E32-T333-S5 1M
E32-T33 1M
17
75
12
55
10
6
25
4
10
30
140
0.8
4
φ3
Through-
beam
models
φ0.5 × 40
45
130
530
3
φ0.9 × 40
M3
M4
φ2
E32-TC200F4R 2M
E32-TC200BR 2M
E32-D331 2M
220
1,000
7
160
700
5
75
φ1.2 × 90
φ0.5 × 15
350
2
φ0.8 × 15
φ1.2 × 40
φ2.5 × 90
φ3
E32-D33 2M
35
25
16
10
Reflective
models
M3
M6
E32-DC200F4R 2M
E32-DC200BR 2M
70
50
30
20
8
420
300
170
120
50
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
9
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Movable section (Flexibility)
Sensing distance (unit: mm)
Sensing
Type
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
Tough mode
method
mode
speed mode
M3
M4
φ1.5
φ3
Standard
Small
M3
E32-T21 2M
E32-T11 2M
340
1,250
340
240
900
240
900
900
180
50
200
110
450
110
450
450
85
45
180
45
180
180
35
8
Screw-shaped
model
680
200
680
680
150
30
Through-
Cylindrical
beam
E32-T22B 2M
E32-T12B 2M
E32-T15XB 2M
E32-T25XB 2M
E32-D21 2M
model
1,250
1,250
250
models
Flat model
70
20
Screw-shaped
model
M4
E32-D21B 2M
E32-D11 2M
150
110
300
50
70
45
20
50
8
M6
420
170
30
120
20
Reflective
models
φ1.5
φ3
Standard
Small
E32-D22B 2M
E32-D221B 2M
E32-D15XB 2M
E32-D25XB 2M
70
Cylindrical
model
150
110
300
85
70
45
20
50
15
420
170
50
120
30
Flat model
120
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Heat-resistance model
Sensing distance (unit: mm)
Sensing
method
Operating
temperature
High-resolution
mode
Standard
mode
High-speed Super-high-
Lens
Model
E32-T51R 2M
E32-T51R 2M + E39-F1
Tough mode
mode
speed mode
110
760
1,400
200
700
2,600
60
---
800
4,000 ✽
4,000 ✽
1,400
4,000 ✽
4,000 ✽
420
560
3,900
4,000 ✽
1,000
3,400
4,000 ✽
300
425
280
100°C
150°C
Lens
2,900
4,000 ✽
760
1,900
3,600
500
High-power lens E32-T51R 2M + E39-F16
---
E32-T51 2M
Lens
E32-T51 2M + E39-F1-33
2,660
4,000 ✽
230
1,150
4,000 ✽
150
Through-
beam
models
High-power lens E32-T51 2M + E39-F16
E32-T54 2M
---
E32-T81R-S 2M
E32-T61-S 2M
500
360
280
180
70
200°C
350°C
840
4,000 ✽
600
4,000 ✽
450
300
120
900
120
1,500
40
Lens
---
E32-T61-S 2M + E39-F1
E32-T61-S 2M
3,400
2,200
300
840
600
450
High-power lens E32-T61-S 2M + E39-F16
E32-D51R 2M
4,000 ✽
330
4,000 ✽
240
4,000 ✽
135
3,900
95
100°C
150°C
200°C
350°C
400°C
E32-D51 2M
560
400
230
160
72
Reflective
models
---
E32-D81R 2M
E32-D61 2M
E32-D73 2M
210
150
90
60
27
210
150
90
60
27
140
100
60
40
18
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Chemical-resistance / Oil-resistance model
Sensing distance (unit: mm)
Sensing
Type
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T12F 2M
Tough mode
method
mode
speed mode
φ5
φ7.2
φ5
4,000 ✽1
3,500
4,000 ✽1
3,000
2,000
800
E32-T11F 2M
2,500
2,000
1,300
900
520
E32-T51F 2M
2,500
700
1,800
500
1,400
350
100
180
Heat-resistance model
Through-
beam
models
φ5
Side view
E32-T14F 2M
E32-T11U 2M
400
680
250
450
M4
1,250
900
Chemical-resistance cable
M4
E32-T11NU 2M
E32-D12F 2M
E32-D14F 2M
720
--- ✽2
--- ✽2
520
160
70
400
95
260
65
100
30
Right angle Chemical-resistance cable
φ6
φ7
Reflective
Side view
models
40
30
10
M6
E32-D11U 2M
420
300
170
120
50
Chemical-resistance cable
✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
✽2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Vacuum-resistance model
Sensing distance (unit: mm)
Sensing Operating ambient
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T51V 1M
Tough mode
method
temperature
120°C
mode
speed mode
360
1,890
290
260
1,350
210
200
130
680
100
320
50
260
35
Top view
Through-
beam
E32-T51V 1M + E39-F1V
E32-T54V 1M
1,000
130
models
Right angle
200°C
E32-T84SV 1M
880
630
480
130
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
10
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Long distance / Dust resistance (High-power),
Detection through gaps (Narrow vision field)
Sensing distance (unit: mm)
Sensing
method
Sensing direction /
Lens type
High-resolution
mode
Standard
mode
High-speed Super-high-
Type
Model
E32-T17L 10M
E32-T14 2M
E32-T11N 2M + E39-F1
Tough mode
mode
speed mode
4,000
900
Top view
Side view
High-power
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
725
4,000 ✽2
4,000 ✽2
1,170
4,000 ✽2
4,000 ✽2
1,150
4,000 ✽2
4,000 ✽2
1,150
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
500
4,000 ✽2
4,000 ✽2
840
20,000 ✽1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
520
4,000 ✽2
4,000 ✽2
840
4,000 ✽2
4,000 ✽2
820
4,000 ✽2
4,000 ✽2
820
20,000 ✽1
3,400
3,700
4,000 ✽2
3,700
4,000 ✽2
400
4,000 ✽2
4,000 ✽2
700
10,000
High-power
(integrated unit)
2,250
2,400
4,000 ✽2
2,400
4,000 ✽2
250
970
Ultrahigh-power E32-T11N 2M + E39-F16
High-power E32-T11R 2M + E39-F1
Ultrahigh-power E32-T11R 2M + E39-F16
1,800
970
1,800
100
Side view
E32-T11R 2M + E39-F2
E32-TC200 2M + E39-F1
High-power
2,600
4,000 ✽2
450
1,500
4,000 ✽2
160
Ultrahigh-power E32-TC200 2M + E39-F16
Side view
E32-TC200 2M + E39-F2
E32-T11 2M + E39-F1
High-power
3,600
4,000 ✽2
660
2,300
4,000 ✽2
430
930
Ultrahigh-power E32-T11 2M + E39-F16
2,300
160
Through-
beam
models
Side view
E32-T11 2M + E39-F2
E32-T11U 2M + E39-F1
High-power
(with lens unit)
High-power
3,600
4,000 ✽2
660
2,300
4,000 ✽2
430
930
Ultrahigh-power E32-T11U 2M + E39-F16
2,300
160
Side view
E32-T11U 2M + E39-F2
E32-T11NU 2M + E39-F1
High-power
2,600
4,000 ✽2
2,000
4,000 ✽2
2,100
3,600
280
1,300
3,300
1,300
2,300
180
500
Ultrahigh-power E32-T11NU 2M + E39-F16
High-power E32-T81R-S 2M + E39-F1
Ultrahigh-power E32-T81R-S 2M + E39-F16
1,300
520
2,650
4,000 ✽2
360
4,000 ✽2
4,000 ✽2
600
900
Side view
E32-T81R-S 2M + E39-F2
E32-T61-S 2M + E39-F1
70
High-power
3,400
4,000 ✽2
450
2,200
3,900
300
900
Ultrahigh-power E32-T61-S 2M + E39-F16
1,500
120
Side view
Top view
Side view
E32-T61-S 2M + E39-F2
E32-T22S 2M
3,500
2,500
1,900
1,300
1,250
870
500
Narrow vision field
(aperture angle: 4
°)
E32-T24S 2M
2,400
1,750
350
Reflective
models
High-power
Top view
E32-D16 2M
40 to 1,400
40 to 1,000
40 to 700
40 to 450
40 to 240
✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Minute object detection (Small-spot model)
Sensing distance (unit: mm)
Sensing Spot diameter
Focal length
(mm)
High-resolution
mode
Standard
mode
High-speed Super-high-
mode speed mode
Model
Tough mode
method
(mm)
φ
0.1 to 0.6
(Variable)
6 to 15
E32-C42 1M + E39-F3A
E32-C42 1M + E39-F17
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm
φ
0.3 to 1.6
10 to 30
(Variable)
5
7
E32-C42S 1M
Spot diameter of 0.1 mm at 5 mm
Spot diameter of 0.1 mm at 7 mm
Spot diameter of 0.2 mm at 17 mm
Spot diameter of 0.5 mm at 7 mm
Spot diameter of 0.5 mm at 17 mm
φ0.1
φ0.2
φ0.5
E32-C41 1M + E39-F3A-5
E32-C41 1M + E39-F3B
E32-C31 2M + E39-F3A-5
E32-C31 2M + E39-F3B
17
7
Reflective
models
17
Spot diameter of 6 mm at 50 mm
Sensing distance in all mode (40 to 100 mm)
φ6
50
E32-L15 2M
φ4
0 to 20
E32-C31 2M + E39-F3C
E32-C11N 2M + E39-F18
Spot diameter of 4 mm max. at 0 to 20 mm
Parallel light
Spot diameter of 3 mm at 50 mm
Spot diameter of 3 mm at 50 mm
φ3
50
E32-CC200 2M
+
E39-F18
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Area-sensing (Area beam)
Sensing distance (unit: mm)
Sensing
Area range
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
E32-T16PR 2M
Tough mode
mode
speed mode
Side view
Flat view
1,550
1,370
2,000
1,100
980
840
560
480
850
220
190
340
Through-
11mm
beam
E32-T16JR 2M
E32-T16WR 2M
750
models
30mm
1,700
1,300
Side view
Reflective
11mm
E32-D36P1 2M
350
250
150
100
45
models
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
11
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Detection without background interference (Convergent-reflective)
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
Size
Model
E32-L16-N 2M ✽
E32-L24S 2M ✽
E32-L25L 2M ✽
E32-L24L 2M ✽
Tough mode
mode
speed mode
Standard
Small
0 to 15
0 to 12
Flat view
0 to 4
Reflective
models
Top view
Flat view
5.4 to 9 (center 7.2)
2 to 6 (center 4)
---
✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Detection of transparent objects (Retro-reflective)
Sensing
Type
High-resolution
mode
Standard
mode
High-speed Super-high-
Model
Tough mode
method
mode
speed mode
Square
Small
E32-R16 5M + E39-R1 (attached) ✽1
E32-R21 2M + E39-R3 (attached) ✽1
E32-C31 2M + E39-F3R+E39-RP37 ✽1
E32-C31 2M + E39-F3R+E39-RSP1 ✽1
150 to 1,500
10 to 250
150
Retrore-
flective
models
250
600
200
300
100
150
50
75
Film detection ✽2
225
✽1. When using a highly reflective object, light reflected from the object may affect the sensor.
✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens
Unit. Be sure to check operation in advance.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
FPD / Semiconductor / Solar battery industry
Sensing distance (unit: mm)
Sensing
method
Operating
temperature
High-resolution
mode
Standard
mode
High-speed Super-high-
Application
Model
E32-L16-N 2M ✽
E32-L16-N 2M ✽
E32-A08 2M ✽
E32-A08H2 3M ✽
E32-A09 2M
Tough mode
mode
speed mode
Glass detection
0 to 15
0 to 15
0 to 12
70°C
0 to 12
Glass substrate
alignment
10 to 20
10 to 20
15 to 38
15 to 38
20 to 30
300°C
70°C
Reflective
models
Glass substrate
mapping
150°C
300°C
60°C
E32-A09H 2M
E32-A09H2 2M
E32-L11FP 5M
E32-L12FS 5M
E32-L11FS 5M
E32-A03 2M
8 to 20 mm from end of lens (recommended: 11 mm)
8 to 20 mm from end of lens (recommended: 11 mm)
8 to 20 mm from end of lens (recommended: 11 mm)
WET process
70°C
85°C
1,610
1,610
640
1,150
1,150
460
890
890
340
340
600
600
225
225
250
250
100
100
Through-
beam
models
E32-A03-1 2M
E32-A04 2M
Wafer mapping
70°C
E32-A04-1 2M
640
460
✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Liquid-level detection model
Sensing distance (unit: mm)
Sensing
method
Sensing
direction
High-resolution
mode
Standard
mode
High-speed Super-high-
mode speed mode
Pipe diameter
No limit
Model
E32-D36T 5M ✽
Tough mode
Applicable pipe: Transparent (no restriction on diameter)
Mounted to pipe
Wet
Reflective
models
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,
recommended pipe wall thickness: 1 mm
φ8 to 10mm
---
E32-L25T 2M
E32-D82F1 4M ✽
Wet model
✽ If a high level of light is received, perform power tuning to reduce the amount of light that is received.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
12
E3X-DA-S
I/O Circuit Diagrams
NPN Output
Operation
Operation
selector
Model
mode
Timing charts
Output circuit
ch1/
ch2
Incident light
No incident light
E3X-DA21-S
Display
Operation indicator
(orange) ch2
Operation indicator
(orange)
ON
OFF
ON
OFF
Operate
Reset
Brown
Black
LIGHT ON
(L-ON)
Opera-
tion
indicator
(orange)
ch1
Light-ON
Output transistor
Load
Load
Photo-
Control output
Orange
Load
(e.g., relay)
electric
Sensor
main
ch1
12 to
24 VDC
E3X-DA21-S
E3X-DA21R-S
E3X-DA21F-S
(Between brown and black (orange) leads)
Control output
Pink
circuit
ch2 ✽1
ch1/
ch2
Incident light
No incident light
External
Operation indicator
(orange)
ON
OFF
ON
input ✽2
Blue
DARK ON
(D-ON)
Dark-ON
Light-ON
Dark-ON
Output transistor
OFF
✽1. For the E3X-DA21R-S, this is the APC alarm output.
This output does not exist on the E3X-DA21F-S.
✽2. This input does not exist the E3X-DA21F-S.
Operate
Reset
Load
(e.g., relay)
(Between brown and black (orange) leads)
ch1/
ch2
Incident light
No incident light
E3X-DA7-S
Operation indicator
Operation indicator
(orange)
ON
OFF
ON
Display
(orange) ch2
Brown
LIGHT ON
(L-ON)
Opera-
tion
indicator
(orange)
ch1
Output transistor
Load
Black
OFF
Operate
Reset
Photo-
Control output Load
Load
(e.g., relay)
electric
Sensor
main
ch1
Orange
12 to
24 VDC
E3X-DA7-S
E3X-DA7R-S
E3X-DA7F-S
(Between brown and black (orange) leads)
Control output
ch2
✽
circuit
ch1/
ch2
Incident light
No incident light
Blue
Operation indicator
(orange)
ON
OFF
ON
DARK ON
(D-ON)
Output transistor
OFF
Operate
Reset
(Between brown and black (orange) leads)
✽ For the E3X-DA7R-S, this is the APC alarm output.
This output does not exist on the E3X-DA7F-S.
Load
(e.g., relay)
PNP Output
Model
Operation
mode
Operation
selector
Timing charts
Output circuit
ch1/
ch2
Incident light
No incident light
E3X-DA51-S
Operation indicator (orange) ch2
Display
Operation indicator
(orange)
ON
OFF
ON
Brown
LIGHT ON
(L-ON)
Opera-
Light-ON
Dark-ON
Light-ON
Dark-ON
External
Output transistor
tion
input ✽2
Pink
OFF
indicator
Control output
ch1
Operate
Reset
(orange)
ch1
Load
(e.g., relay)
Photo-
electric
Sensor
main
Black
12 to
24 VDC
E3X-DA51-S
E3X-DA51R-S
E3X-DA51F-S
(Between blue and black (orange) leads)
Control output
Orange
ch2 ✽1
Load
circuit
ch1/
ch2
Incident light
No incident light
Load
Blue
Operation indicator
(orange)
ON
OFF
ON
DARK ON
(D-ON)
Output transistor
OFF
✽1. For the E3X-DA51R-S, this is the APC alarm output.
This output does not exist on the E3X-DA51F-S.
✽2. This input does not exist the E3X-DA51F-S.
Operate
Reset
Load
(e.g., relay)
(Between blue and black (orange) leads)
ch1/
ch2
Incident light
No incident light
E3X-DA9-S
Operation indicator (orange) ch2
Operation indicator
(orange)
Display
ON
OFF
ON
OFF
Operate
Reset
Brown
LIGHT ON
(L-ON)
Opera-
tion
indicator
(orange)
ch1
Output transistor
Photo-
electric
Sensor
main
Control output
Black
Load
(e.g., relay)
ch1
12 to
24 VDC
E3X-DA9-S
E3X-DA9R-S
E3X-DA9F-S
(Between blue and black (orange) leads)
Control output
Orange
ch2
✽
circuit
Load
ch1/
ch2
Incident light
No incident light
Load
Blue
Operation indicator
(orange)
ON
OFF
ON
DARK ON
(D-ON)
Output transistor
OFF
✽ For the E3X-DA9R-S, this is the APC alarm output.
This output does not exist on the E3X-DA9F-S.
Operate
Reset
(Between blue and black (orange) leads)
Load
(e.g., relay)
Note: 1. Operation with area settings is as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2. Timing Charts for Timer Settings (T: Set Time)
ON delay
OFF delay
One-shot
ON delay and OFF delay
Incident light
Incident light
Incident light
Incident light
No incident light
No incident light
No incident light
No incident light
T2
T1
T1
T2
T
T
T
T1: ON-delay set time
T2: OFF-delay set time
T1 and T2 can be set separately.
ON
OFF
ON
ON
ON
ON
L-ON
D-ON
L-ON
L-ON
L-ON
OFF
OFF
OFF
T
T
T
ON
ON
ON
D-ON
D-ON
D-ON
OFF
OFF
OFF
OFF
13
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings,
etc.
Operation Keys
Function setting
UP
Lock lever
Locks the fiber.
operations
DOWN
MODE
Channel Selector
Operation Indicator
(ch2) (orange)
Operation Indicator
(ch1) (orange)
ON when output is ON.
Note: Nomenclature and operating procedures for the E3X-
DA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on
pages 19 and 20.
Use to select the channel to display and set.
ON when output is ON.
Mode Selector
Use to select SET or RUN Mode.
OFF when output is OFF. OFF when output is OFF.
Operating Procedure
1
Setting the Operation Mode
To restore the default
✽
DOWN
MODE
Press
both
for 3 s.
power setting:
The operation mode is set in SET Mode.
➜Refer to 5. Setting Functions on page 16.
✽ Press the DOWN Key
right after pressing
the MODE Key.
PTUN
OFF
Set the Channel Selector Switch to the desired channel
before making any adjustments or settings.
"OFF" will flash twice.
2
Adjusting the Power (RUN Mode)
Incident level
Threshold
The current incident light level can be adjusted near the
power tuning target value (default: 2,000).
This restores the default
setting.
✽ Confirm that the MODE Key setting is PTUN (power tuning). The
✽ Setting Errors
default setting is PTUN.
➜Refer to 5. Setting Functions on page 16.
An error has occurred if one of the following displays appears after
the progress bar is displayed.
✽ If power tuning is executed while SHS is selected for the detection
function, the minimum power will be set.
Display
Error
Action
Flashes twice
Over Error
The power will not
be tuned. The power
can be increased up
to approximately 5
times the incident
light value.
The incident light
level is too low
for the power
tuning target
value.
Incident level
Threshold (default)
Set the SET/RUN Mode
Selector Switch to RUN.
PTUN
PTUN
OVER
RUN
(Factory-set to RUN)
Bottom Error
The power will be
turned to the
minimum level. The
power can be
decreased down to
approximately
Flashes twice
The incident light
level is too high
for the power
tuning target
value.
MODE
3 s
BOTM
1/20th the incident
light value.
PTUN
Progress bar
Release the key after
the progress bar is
displayed.
3
Setting Thresholds Manually (RUN Mode)
Display changes after
specific time.
A threshold can be set manually. A threshold can also
be adjusted manually after teaching to fine-tune it.
Power tuning
target value
Light level
Threshold (default)
Set the Mode Selector
Switch to RUN.
Incident level
Threshold
RUN
This completes the
adjustment.
(Factory-set to RUN)
UP
DOWN
Increases threshold.
Decreases threshold.
✽ Even if the display method is changed, the threshold will appear
on the sub-display when the key is pressed.
14
E3X-DA-S
4
Teaching the Threshold (SET Mode)
✽ There are five methods that can be used for teaching, as described
below. Use the method most suitable for the application.
✽ Two-point teaching, positioning teaching, and automatic teaching
can be performed in RUN Mode.
For operating procedures, refer to the Instruction Manual provided
with the product.
4-3. Teaching a Reflective Fiber Unit without a Workpiece
You can set the threshold to above the incident light level without
a workpiece by the percentage set for the teaching level.
➜Refer to 5. Setting Functions on page 16.
✽ An error has occurred if OVER or LO is displayed on the
sub-display. If that occurs, repeat the operation from the beginning.
Incident level
Threshold
Set the SET/RUN Mode
Selector Switch to SET.
SET
4-1. Setting the Threshold at Maximum Sensitivity
The threshold can be set to the maximum sensitivity.
This is useful when the longest detection distance is
required.
UP
DOWN
Press
either
for 1 s.
With no workpiece:
Incident level
Threshold
Set the SET/RUN Mode
TECH
----
Selector Switch to SET.
SET
"----" will be displayed.
UP
DOWN
Press
either
UP
DOWN
With no workpiece:
Press
either
for 3 s.
for 3 s.
FULL
Threshold
The threshold that
was set will flash twice.
RFCT
Threshold
The threshold that
was set will flash twice.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Incident level
Threshold
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Incident level
Threshold
4-4. Two-point Teaching
4-5. Positioning Teaching
4-2. Teaching a Through-beam Fiber Unit without a Workpiece
You can set the threshold to below the incident light level
without a workpiece by the percentage set for the teaching
level.
Two points in the following figures are detected, and
the intermediate point of the light levels for the
two points is set as the threshold.
➜Refer to 5. Setting Functions on page 16.
Incident level
Threshold
Incident level
Threshold
Set the SET/RUN Mode
Set the SET/RUN Mode
Selector Switch to SET.
Selector Switch to SET.
SET
SET
UP
DOWN
Press
either
for 1 s.
With a workpiece:
For positioning
teaching, place the
workpiece where
you want to
UP
DOWN
Press
either
With no workpiece:
for 1 s.
TECH
----
Workpiece
position it.
TECH
----
"----" will be displayed.
"----" will be displayed.
RUN
To RUN
With no workpiece:
For positioning
teaching, place the
workpiece where
you want to
UP
DOWN
Press
either
for 1 s.
THRU
Threshold
Threshold
The threshold that
was set will flash twice.
position it.
2PNT
Threshold
Threshold
The threshold that
was set will flash twice.
Incident level
This completes the
setting procedure.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Incident level
15
E3X-DA-S
5
Setting Functions (SET Mode)
✽ The function transition boxes show the default settings.
✽ More functions may be displayed depending on the detailed settings.
➜Refer to 4. Teaching the
Threshold on page 15.
Moving between Functions
Teaching
0. Operation mode
(To set the operation mode)
1. Detection
(To change response speed and
3. Teaching level
(To change the teaching level)
2. Timer
(To use the timer setting)
Set the SET/RUN Mode
Selector Switch to SET.
SET
detection precision)
11. External input memory
(Refer to the Instruction Manual
provided with the sensor.)
4. ATC setting
(To change the ATC setting)
MODE
10. External input
9. Output setting
8. ECO Mode
7. Display orientation
6. Display switch
5. MODE Key
(To change functions controlled
(To change outputs for
(To set the ECO Mode)
(To change the display method)
(To change the function of the
(To reverse the orientation of
MODE Key during operation)
the display.)
using the external input)
channel 2)
Set the SET/RUN Mode
Selector Switch to RUN.
RUN
When the
settings have
been completed
Functions
UP
DOWN
Use the UP and DOWN Keys to change the settings.
Function ✽
Setting (display)
Description
➜Refer to 1. Setting the Operation Mode on page 14.
Light ON:
, Dark ON:
0. Operation mode
1. Detection ✽
Super-high-speed:
High-resolution:
, High-speed:
, Tough: , Differential operation:
, Standard:
,
Used to change the response speed or detection precision.
Used to set the edge to be detected.
Differential edge
(differential operation
selected)
Single edge:
, Double edge:
Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms:
Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms:
,
Differential time
Used to set the differential response time.
Timer disabled:
ON-delay timer:
, OFF-delay timer:
, One-shot timer:
,
2. Timer
Used to enable or disable timers.
ON-delay + OFF-delay timer:
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments,
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments
Time
(timer enabled)
Used to change timer settings when timers are enabled.
The timer can be set from 1 to 5,000 ms.
Used to change the threshold setting when teaching a
Through-beam Fiber Unit without a workpiece or teaching
a Reflective Fiber Unit without a workpiece.
3. Teaching level
Setting range:
to
4. ATC setting
ATC enabled:
No setting:
, ATC disabled:
Used to enable or disable the ATC function.
Setting at Power-ON
(ATC ON)
, ATC start processing:
,
Used to set the processing to be performed when the
power is turned ON.
Power tuning and ATC start processing:
Executes power tuning:
Executes a zero reset:
Automatic teaching:
,
Used to change the function of the MODE Key during RUN
operation.
5. MODE Key ✽
, Two-point teaching:
, ATC start:
,
Used to set target values during power tuning.
➜Refer to 2. Adjusting the Power on page 14.
Power tuning target value
(performing power tuning)
Setting range: 100 to 3,900 (increments of 100)
Maximum power :
✽ The detection settings and MODE Key settings are the same for channel 1 and channel 2.
Other functions can be set separately for each channel.
16
E3X-DA-S
Function
Setting (display)
Description
Used to display the incident light level and the
threshold.
Incident level Threshold
% incident level Threshold
Used to display the incident light level as a percentage of
the threshold and the threshold.
Used to display the peak and bottom levels of incident
light within a set time. (Updated every 2 s.)
Fixed interval
PEAK
L-PE
BOTM
D-BT
Use to display the incident light peak level and no incident
light bottom level. (Refreshed when output turns ON or OFF.)
6. Display switch
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red, OFF: Green)
Detection status
Used to display the current incident light level and the peak
incident light level. Display changes at a fixed interval.
Fixed interval
Current incident
level
PEAK
Current incident Peak incident
level level
Used to display the incident light level and the channel
(unit number).
Incident level Channel (unit number)
7. Display orientation
Normal display:
, Up/down reversed display:
Used to reverse the orientation of the display.
Used to enable or disable the ECO mode.
8. ECO Mode
Lit degital display:
OFF:
, Dimmed degital display:
,
Used to change the output details for channel 2.
This setting will be disabled if the detection function is set
to DIFF (i.e., differential operation) and the output will be
used for an alarm output.
Each channel:
Output when the incident light level is between two thresholds:
Self-diagnosis output:
,
9. Output setting
10. External input
,
Through-beam, no-workpiece teaching:
Reflective, no-workpiece teaching:
Two-point teaching:
Power tuning:
,
Used to change the functions to be controlled using the
external input.
(Refer to the Instruction Manual provided with the sensor.)
,
, Automatic teaching:
, Zero reset:
,
,
Light OFF:
, ATC start:
Write results to EEPROM:
,
11. External input
Used to set writing the results.
Do not write results to EEPROM:
memory
(Refer to Instruction Manual provided with the product.)
17
E3X-DA-S
6
Convenient Functions
6-1. Setting the Digital Display to Zero (Zero Reset)
6-3. Resetting Settings (Initial Reset or User Reset)
The incident light level on the main display can be set to 0.
The incident light level and the threshold will both be
shifted. This is useful when you want to set the reference
display to zero.
All settings can be returned to the factory defaults or to
user-saved settings.
Set the SET/RUN Mode
UP
DOWN
Press
both
for 5 s.
Selector Switch to SET.
SET
✽ Change the function to 0RST (zero reset) with the MODE Key.
The default setting is PTUN.
➜Refer to 5. Setting Functions on page 16.
RST
INIT
RST
USER
Set the SET/RUN Mode
MODE
UP
DOWN
Selector Switch to RUN.
3 s
RUN
MODE
MODE
Factory setting
USER
YES?
USER
NO?
To return to original value for incident light level:
Set the SET/RUN Mode
✽1
DOWN
MODE
Press
Selector Switch to RUN.
both
RUN
UP
DOWN
for 3 s.
MODE
MODE
Factory setting
Perform user reset.
Operation canceled.
6-2. Locking the Keys (Key Lock)
(The steps within the dotted lines can be used if settings have
been saved by the user.)
All key operations can be disabled.
Set the SET/RUN Mode
✽2
UP
MODE
Press
both
INIT
NO?
INIT
YES?
Selector Switch to RUN.
for 3 s.
RUN
Factory setting
LOC
ON
UP
DOWN
MODE
MODE
“LOC ON” will flash twice
and key operations will be
disabled.
Operation canceled.
Settings initialized.
To release the lock:
Saving User Settings
The current settings can be saved.
✽2
Set the SET/RUN Mode
UP
MODE
Press
both
Selector Switch to RUN.
RUN
for 3 s.
Set the SET/RUN Mode
UP
MODE
Press
both
Factory setting
Selector Switch to SET.
for 5 s.
SET
LOC
“LOC OFF” will flash twice
and key operations will be
enabled.
OFF
SAVE
YES?
SAVE
NO?
✽ If a key is pressed while key operations are locked, “LOC ON” will
flash twice on the display to
UP
DOWN
MODE
MODE
indicate that key operations have
been disabled.
The current settings are saved.
Operation canceled.
✽1. Press the DOWN Key right after pressing the MODE Key.
✽2. Press the UP Key right after pressing the MODE Key.
18
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@R-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings, etc.
Operation Keys
UP
Lock lever
Locks the fiber.
Function setting
DOWN
MODE
operations
Easy key lock Selector
Select to lock or unlock settings.
Operation Indicator APC alarm output
(orange)
indicator (orange)
ON when output is ON.
OFF when output is OFF.
Mode Selector
Use to select SET or RUN Mode.
ON when output is ON.
OFF when output is OFF.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@R-S.
Margin
Margin
APC
APC
Initial status
1
Locking the Keys (Easy Key Lock)
Before shipment, all key operation except for the MODE
Keys can be disabled.
APC margin
Set the Easy Key Lock
Set the SET/RUN Mode
displayed in
Selector Switch to Locked .
Selector Switch to RUN.
decrements of 10%
Locked
RUN
(Factory-set to RUN)
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Margin
APC
Unlocking
APC margin of less
than 10%
Set the Easy Key Lock
The display switches
every second.
Set the SET/RUN Mode
Selector Switch to Unlocked .
Selector Switch to RUN.
Unlocked
ALAT
APC
RUN
(Factory-set to RUN)
Margin
APC
2
Displaying the APC Margin
Displaying the APC margin can be useful for planning
maintenance. When the APC margin is 0%,
APC alarm output will turn ON, and the APC alarm output
indicator will light regardless of the operation of the APC
margin display.
APC margin is 0%.
The display switches
every 0.5 s.
END
APC
Set the Easy Key Lock
Set the SET/RUN Mode
Selector Switch to Locked .
Selector Switch to RUN.
Locked
RUN
Press the MODE Key
or press nothing for 10 s.
MODE
(Factory-set to RUN)
MODE
Press the MODE Key to
display the following for 10 s.
Incident level
Threshold
The display will return
to the normal display.
19
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@F-S (@: 21/51/7/9)
Main Display (Red)
Incident level, function, etc.
Sub-Display (Green)
Threshold, function settings, etc.
Operation Keys
UP
Lock lever
Locks the fiber
Function setting
DOWN
MODE
operations
Easy key lock Selector
Select to lock or unlock settings.
Operation Indicator
(orange)
ON when output is ON.
OFF when output is OFF.
Power tuning
indicator (orange)
ON when setting is ON.
OFF when setting is OFF.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@F-S.
"A" is displayed when
the output is ON or until
approximately 10 s
A
1
Locking the Keys (Easy Key Lock)
has elapsed. (Key
operations will not be
accepted in the status.)
Before shipment, all key operation except for the MODE
Keys can be disabled.
STAT
"STAT" will be displayed
and the slow-motion
display will start.
Set the Easy Key Lock
Set the SET/RUN Mode
Selector Switch to Locked .
Selector Switch to RUN.
Locked
RUN
(Factory-set to RUN)
Incident level
Incident level
Incident level
Threshold
Threshold
Threshold
The incident level in
intervals of 17 µs
will be displayed
for approximately 20 s
every 160 ms
(between 0.5 ms before
ON to 1.5 ms after ON).
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Unlocking
Set the Easy Key Lock
Set the SET/RUN Mode
Selector Switch to Unlocked .
Selector Switch to RUN.
Unlocked
RUN
(Factory-set to RUN)
2
Displaying the Change of the incident level
Press the MODE Key,
or wait for the slow-motion
display to end.
MODE
Changes of the incident level for high-speed workpiece
detection can be displayed. This enables checking the
margin level of light received and the workpiece ON time
in slow motion.
Output ON time Unit: µs
Set the Easy Key Lock
The output ON time will
be displayed.
Set the SET/RUN Mode
Selector Switch to Locked .
Selector Switch to RUN.
Locked
RUN
(Factory-set to RUN)
END
END will be displayed.
Incident level
Threshold
Turn OFF the output or
convey the workpieces.
Incident level
Threshold
MODE
The display will return to
Press the MODE key.
the normal display.
The following will be displayed
if the ON time exceeds 1,500 µs.
The following will be displayed
if the change in the light amount is low. ✽
Error
Display
✽ This may also be displayed when detecting
a workpiece with a small change in light amount
or a slow workpiece of 1,500 µs or longer.
OVER
US
NON
DETC
20
E3X-DA-S
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor.
WARNING
Precautions for Correct Use
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
CAUTION
The sensor is ready to detect within 200 ms after the power supply is
turned ON. If the sensor and load are connected to separate power
supplies, be sure to turn ON the sensor first.
Time may be required for the incident level to stabilize after the power
supply is turned ON.
Do not use the sensor with voltage in excess of the
rated voltage. Excess voltage may result in
malfunction or fire.
Never use the sensor with an AC power supply.
Otherwise, explosion may result.
Operation at Power OFF
A pulse may be output when the power supply is turned OFF. Turn
OFF the power supply to the load or the load line before turning OFF
the power supply to the sensor.
Mutual Interference Protection Function
Precautions for Safe Use
Mutual interference prevention is enabled if Amplifier Units are
connected together. It is also enabled in the same way if E3X-DA-S-
series Units and E3C-LDA-series Units are used together.
The following precautions must be observed to ensure safe operation
of the sensor.
1. Do not use the sensor in an environment where explosive or
flammable gas is present.
2. Do not use the sensor in a location subject to splattering with
water, streams, oils, or chemicals.
3. Do not attempt to disassemble, repair, or modify the sensor.
4. Do not apply voltages or currents that exceed the rated range to
the sensor.
Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave connector into the Amplifier Unit until it
clicks into place.
5. Do not use the sensor in an ambient atmosphere or environment
that exceeds the ratings.
6. Wire the power supply correctly, including the polarity.
7. Connect the load correctly.
8. Do not short-circuit the load at both ends.
9. Do not use the sensor if the case is damaged.
10.Dispose of the sensor as industrial waste.
11.Do not use the sensor in locations subject to direct sunlight.
Insert
2. Attach the protective seals (provided as accessories) to the sides
of master and slave connectors that are not connected.
Seal
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit away from the other unit.
2. After the Amplifier Unit has been separated, press down on the
lever on the connector and remove it. (Do not attempt to remove a
connector without first separating the Amplifier Unit from the other
Units.)
Press down
Lever
Remove
21
E3X-DA-S
Adding and Removing Amplifier Units
Adding Amplifier Units
Fibers with E39-F9 Attachment
1. Mount the Amplifier Units one at a time onto the DIN track.
Fiber Unit
9 mm
13 mm
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Click into place
9 mm
13 mm
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Note: 1. The specifications for ambient temperature will vary
according to the number of Amplifier Units used together.
For details, ➜refer to Ambient temperature range on
page 4.
Protective cover
Unlocked
Locked
2. Always turn OFF the power supply before joining or
separating Amplifier Units.
Mounting the End Plate (PFP-M)
Use an End Plate if the Amplifier Unit might move due to vibration.
Note: 1. To maintain the fiber properties, confirm that the lock is
released before removing the fibers.
2. Be sure to lock or unlock the lock lever within an ambient
temperature range between −10°C and 40°C.
Adjusting
Mutual Interference Protection Function
The values that appear on the digital display may fluctuate somewhat
due to light from other sensors. If this occurs, you can stabilize
detection by setting a threshold that is close to half way between the
incident levels with and without a sensing object.
End Plate
Fiber Connection
The E3X Amplifier Unit has a lock lever for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
Output Short-circuits
OVER/CUR will flash on the display if the output short-circuit
protection function operates due to a load short-circuit in a control
output. If this occurs, check the load connections.
1. Connecting Fibers
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Protective cover
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Lock lever
Unlocked
Locked
Insertion position
Others
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Fiber insertion mark
Fiber
Mobile Console
9 mm
The E3X-MC11-SV2 Mobile Console does not currently support the
new Tough Mode and ON-delay + OFF-delay timer. You also cannot
use the E3X-MC-S.
Note: Do not pull on the fiber, apply pressure on it, or otherwise
subject it to excessive force when it is attached to the
Amplifier Unit. (Use a force of 0.3 N·m max.)
Communications Unit
Use an E3X-DRT21-S Version 3 Communications Unit. This is not
supported for the E3X-DA@R-S and E3X-DA@F-S (@: 21/51/7/9).
22
E3X-DA-S
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Amplifier Units
Pre-wired Models
E3X-DA21-S
E3X-DA51-S
Digital Display Area
✽1. The indicators are as follows:
Indicator ✽1
E3X-DA21-S
E3X-DA51-S
Operation indicator
(2 ch)
15.6
35.25
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
100
E3X-DA21R-S
E3X-DA51R-S
APC alarm output
indicator
6.3
E3X-DA21F-S
E3X-DA51F-S
Power tuning
indicator
Operation indicator (1ch)
Main display
Sub-display
DIN track mounting
4.3
141.1
180°
101.45
Vinyl-insulated round cable
Standard length: 2 m ✽2
322
(9)
4.5
Multiple connection diagram
12.5
End Plate
5.65
3.4
(sold separately)
PFP-M
L
Hole for optical communications
Two, 2.4 dia.
18.7
(36.2)
(21.3)
700
Center of DIN track
DIN track
(sold separately)
PFP-@N
10
10
The number of expansion
L (mm)
10
20
1
2
3
30
4
40
Fiber Attachment mounted (E39-F9)
5
50
6
7
60
70
100
8
80
9
90
10
100
With Mounting Bracket Attached
4.3
141.1
180°
101.45
Vinyl-insulated round cable
Standard length: 2 m ✽2
322
(9)
4.5
12.5
5.65
3.4
Two, 2.4 dia.
Two, 3.2 dia.
Holes
Hole for optical communications
4.3
18.7
16
700
10.3
(9.4)
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Mounting Holes
3.4
4.4
2-M3
16
28.1
16
✽2. The cable specifications are as follows:
Fiber Attachment mounted (E39-F9)
E3X-DA21-S
4 dia. cable / 5 conductors
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
4 dia. cable / 3 conductors
E3X-DA21F-S
E3X-DA51F-S
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the
Amplifier Units if they are mounted side by side.
23
E3X-DA-S
Wire-saving connector Models
E3X-DA7-S
E3X-DA9-S
Digital Display Area
✽1. The indicators are as follows:
Indicator ✽1
E3X-DA7-S
E3X-DA9-S
Operation indicator
(2 ch)
15.6
35.25
E3X-DA7R-S
E3X-DA7R-S
E3X-DA9R-S
APC alarm output
indicator
E3X-DA9R-S
E3X-DA7F-S
6.3
Sub-display
10
E3X-DA7F-S
E3X-DA9F-S
Power tuning
indicator
Operation indicator (1ch)
4.3
Main display
E3X-DA9F-S
DIN track mounting
141.1
8.1
180°
101.45
Dia. A ✽2
32
(9)
4.5
12.95
5.65
3.4
Hole for optical communications
Two, 2.4 dia.
18.7
Multiple connection diagram
(36.2)
(21.3)
End Plate
700
(sold separately)
PFP-M
L
Center of DIN track
DIN track
(sold separately)
PFP-@N
10
10
The number of expansion
L (mm)
10
Fiber Attachment mounted (E39-F9)
1
2
20
3
30
4
40
5
50
6
60
7
70
10
8
80
9
10
90
100
With Mounting Bracket Attached
4.3
141.1
8.1
180°
101.45
Dia. A ✽2
32
(9)
4.5
12.95
5.65
3.4
Two, 3.2 dia.
Holes
18.7
Hole for optical communications
Two, 2.4 dia.
4.3
(9.4)
16
700
10.3
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Mounting Holes
3.4
4.4
2-M3
✽2. The cable diameters are as follows:
E3X-CN21 (4 conductors)
E3X-CN22 (2 conductors) 4.0 dia.
E3X-CN11 (3 conductors)
16
28.1
16
Fiber Attachment mounted (E39-F9)
E3X-CN12 (1 conductor) 2.6 dia.
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier
Units if they are mounted side by side.
24
E3X-DA-S
Wire-saving connector
Master connector
E3X-CN21
2,000+50
0
Edge of amplifier
(7)
✽
✽ E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector
E3X-CN22
2,000+50
0
Edge of amplifier
(7)
✽
✽ E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Master connector
E3X-CN11
2,000+50
0
Edge of amplifier
(7)
✽
✽ Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector
E3X-CN12
2,000+50
0
Edge of amplifier
(7)
✽
✽ Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
25
E3X-DA-S
Accessories (sold separately)
Mounting Brackets
E39-L143
34.8
22
2.5
3
(10.3)
16
Mounting Holes
7.3
5.3
2-M3
26.8
7
Two, 3.2 dia.
±0.1
16
3
16
3
Four, R1.7
10.3 10 max.
7
3.4
Material: Stainless steel (SUS304)
1
3.4
1
End Plate
PFP-M
50
M4×8
11.5
panhead screw
10
M4 spring washer
4.8
6.2
10
1
1.3
1.8
35.5
35.3
1.8
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
26
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
OMRON Corporation
Tokyo, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
Sensor Business Unit
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
© OMRON Corporation 2010 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Printed in Japan
(0510)
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
CSM_1_1_0510
Cat. No. E396-E1-02