Temperature Controllers  
E5J  
Advanced PID Controller with Fuzzy Logic-Based Adaptive Tuning  
Provides Optimum Performance  
Available in 3 standard DIN sizes:  
Choose 1/4, 1/8 and 1/16 DIN  
Fuzzy adaptive tuning continually optimizes  
PID control based on current process conditions  
Field selectable sensor inputs, alarm functions  
and °F/°C scaling  
Digital inputs allow Run/Stop operation and  
external selection of multiple set points on 1/4  
and 1/8 DIN units  
Plug-in outputs on 1/4 and 1/8 DIN units provide  
field interchangeability and easy servicing  
1/4 and 1/8 DIN units offer serial communication  
options for interfacing with PLCs and other host  
devices  
Ordering Information  
1/4 and 1/8 DIN CONTROLLERS  
Order control outputs separately below; for example, E5AJ-A2HB-F with E53-R output unit. All temperature controllers with communica-  
tions capability have the designated board installed, except E5J-A2HM-F. The E5J-A2HM-F offers interchangeable communications  
boards that must be ordered separately. To order controllers marked for Celsius, drop the final "F" from the part number.  
Part Number  
Size  
Standard  
Serial communications board installed  
Communications ready  
(no board installed)  
E5AJ-A2HM-F  
RS-232C  
RS-422  
RS-485  
1/4 DIN  
1/8 DIN  
E5AJ-A2HB-F  
E5EJ-A2HB-F  
E5AJ-A2H01-F  
E5EJ-A2H01-F  
E5AJ-A2H02-F  
E5EJ-A2H02-F  
E5AJ-A2H03-F  
E5EJ-A2H03-F  
E5EJ-A2HM-F  
1/16 DIN CONTROLLERS  
Part Number  
Relay output  
E5CJ-R2HB-F  
E5CJ-R2-F  
E5CJ-R-F  
Description  
Voltage output  
E5CJ-Q2HB-F  
E5CJ-Q2-F  
Current output  
E5CJ-C2B-F  
E5CJ-C2-F  
E5CJ-C-F  
Two alarm points; one event input, heater burnout alarm (except current)  
Two alarm points; without event input  
Without alarm and event input  
E5CJ-Q-F  
CONTROL OUTPUTS FOR 1/4 AND 1/8 DIN MODELS, CURRENT TRANSFORMERS  
Description  
Feature  
Part number  
Control outputs  
SPDT relay, 5 A, 250 VAC*  
SSR, 1 A, 75 to 250 VAC  
Voltage, 12 VDC, NPN  
E53-R  
E53-S  
E53-Q  
Voltage, 24 VDC, NPN  
E53-Q3  
E53-Q4  
E53-C3  
E53-C3D  
E53-V34  
Voltage, 24 VDC, PNP  
Linear current, 4 to 20 mA DC, 600  
Linear current, 0 to 20 mA, 600 Ω  
Linear voltage, 0 to 10 VDC, 1 KΩ  
E5J  
E5J  
CONTROL OUTPUTS FOR 1/4 AND 1/8 DIN MODELS, CURRENT TRANSFORMERS(continued)  
Linear voltage, 0 to 5 VDC, 1 KΩ  
5.8 mm (0.23 in) dia. hole  
E53-V35  
E54-CT1  
E54-CT3  
Current transformers  
for heater burnout function  
12.0 mm (0.47 in) dia. hole  
*Note: If control period is less than 5 seconds, use solid state relay or voltage relay.  
COMMUNICATIONS BOARDS FOR E5AJ, E5EJ CONTROLLERS  
Output  
Write to temperature controller  
Set temperature, alarm value  
proportional band, integral time,  
rate time, event input.  
Read from temperature controller  
Set temperature, alarm value, proportional  
band, reset time, rate time, output variable  
set limits, process value  
Part number  
E53-J01  
RS-232C  
RS-422  
RS-485  
E53-J02  
E53-J03  
ACCESSORIES  
Description  
Part number  
Y92A-48N  
Y92A-49N  
Y92A-96N  
NEMA 4 covers  
For E5CJ, 1/16 DIN size  
For E5EJ, 1/8 DIN size  
For E5AJ, 1/4 DIN size  
REPLACEMENT PARTS  
Description  
Part number  
Y92F-30  
Panel mounting adapter for E5CJ, supplied with each unit  
TEMPERATURE RANGES  
Input type  
Thermocouple  
Platinum RTD  
100 Ω  
(switch selectable)  
Temperature  
range  
Type K  
Type J and L  
-100 to 850  
-100 to 1,500  
1° C/F  
Type T and U  
-199.9 to 400.0  
-199.9 to 700.0  
0.1° C/F  
Type N  
°C  
°F  
-200 to 1,300  
-300 to 2,300  
1° C/F  
-200 to 1,300  
-300 to 2,300  
1° C/F  
-199.9 to 650.0  
-199.9 to 999.9  
0.1° C/F  
Unit of measure (main  
setting and alarm  
GET THE ADVANTAGE OF ADAPTIVE TUNING USING THREE ALGORITHMS  
Omron's "J" series controllers use fuzzy  
adaptive tuning to continuously monitor  
and optimize PID constants while the  
controller operates. Three tuning  
algorithms are used to recalculate the  
PID constants within 500 ms after the  
process value stabilizes at set point:  
Step-Response Tuning  
Comparison of E5J and E5X  
Tuning Methods  
Maximum  
Set  
Omron's "X" series controllers attempt to  
optimize the PID constants by using a  
limit cycle auto-tune. Although effective in  
most applications, this method has some  
drawbacks. For example, the auto-tuning  
must induce an upset into the process in  
order to make the process oscillate four  
times. In many processes these types of  
artificial upsets are not desirable.  
Adaptive tuning controllers do not induce  
an upset; instead, they use information  
from the actual process, eliminating  
unnecessary oscillations and enabling  
quicker start-up time.  
Deviation  
immediately  
Process  
after set  
point  
Step-response  
• Step-response method  
• Disturbance tuning  
• Hunting tuning.  
Manipulated PID  
Step-Response Method  
Disturbance Tuning  
This tuning method takes place on start-  
up and after an upward set point change  
heating applications or a downward set  
point change in a cooling application.  
Step-response tuning changes mainly  
impact the proportional band.  
Stable  
range  
SP  
Another drawback of the limit cycle auto-  
tune method is that PID constants will  
only be effective so long as the same  
basic conditions that were present when  
the auto-tune took place remain constant.  
Various factors such as a load change,  
heater performance degradation or set  
point changes can cause the auto-tuned  
values to be less than optimum. The new  
adaptive tuning method, however, is  
continually monitoring the process and will  
automatically adjust the PID constants  
whe nprocess parameters (i.e., heater  
degradation, load change, etc.) vary.  
Outside stable  
range here  
Disturbance tuning  
takes place here  
Disturbance Tuning  
This tuning method takes place when the  
temperature exceeds the stable range  
between one and three times before  
settling back to set point. Changes in  
tuning are mainly made to the derivative  
(rate) time.  
Hunting Tuning  
Extreme value  
Stable  
range  
SP  
Hunting  
waveform  
monitored  
Hunting Tuning  
This tuning method takes place when the  
temperature exeeds the stable range four  
or more times before settling back to set  
point. Changes in tuning are mainly  
made to the integral (reset) time.  
PID before tuning  
PID after tuning  
2
E5J  
E5J  
Specifications  
Part number  
E5AJ  
E5EJ  
E5CJ  
Supply voltage  
Operating voltage  
Power consumption  
100 to 240 VAC, 50/60 Hz  
85% to 110% of supply voltage range  
Approx. 10 VA at 100 VAC to 14 VA at 240 VAC  
Approx 10 VA at 100 VAC to  
12 VA at 240 VAC  
Temperature input type  
Thermocouple types J, K, T, L, U, and N or platinum RTD (JPt 100/Pt100), selectable  
Event  
input  
Contact input  
No-contact input  
ON: 1 kmax., OFF: 100 kmin.  
ON: residual voltage: 3 V max.,  
OFF: Leakage current 1 mA max.  
Control  
output  
Type  
Relay  
SPST-NO, 5 A, 250 VAC using E53-R output unit  
SPST-NO, 3 A, 250 VAC  
NPN, 20 mA at 12 VDC  
(see note 1)  
Voltage  
NPN, 40 mA at 12 VDC using E53-Q output unit  
NPN, 20 mA at 24 VDC using E53-Q3 output unit  
PNP, 20 mA at 24 VDC using E53-Q4 output unit  
All offer short-circuit protection  
Current  
4-20 mA, DC, 600 max., resolution of 2,600  
4-20 mA, 600 max., resolution  
using E53-C output unit (see note 1)  
of 2,600  
Hysteresis  
Update  
time  
0.1° to 999.9° C/F in units of 0.1°C/°F during ON/OFF control action  
Output  
Display  
500 ms for pulse output  
500 ms  
Service Electrical  
100,000 operations minimum for E53-R and alarm  
10 million moperations minimum for E53-R and alarm  
life  
Mechanical  
Alarm  
output  
Number  
Two SPST-NO relay,s 3 A, 250 VAC  
Two, SPST-NO relays, 1 A, 250 VAC  
Setting range  
Thermocouple types J, K, L, N: -1999 to 9,999 °C/°F in units of 1 °C/°F  
Platinum RTD and thermocouple types T and U: -199.9 to 999.9 °C/°F in units of 0.1 °C/°F  
SPST-NO relay, 1 A, 250 VAC  
Heater  
Type  
burnout  
output  
Setting range  
0.1 to 49.9 A in units of 0.1 A  
0.0 setting disables the output  
50.0 setting turns output ON continuously  
Minimum detectable  
ON time  
200 ms; heater current is not measured when the control output is ON less than 200 ms  
Indication  
accuracy  
General  
±0.5% of set point or ±1°, whichever is greater, ±1 digit max.  
Exceptions  
Accuracy of types K, N and T thermocouples is ±2°C (3.6°F) from -100°C or below (-240°F or  
below), ±1 digit. Accuracy of type U thermocouple at any temperature is ±2°C (3.6°F), ±1 digit.  
Setting accuracy  
Display Range  
Set value coincides with the indicated value, since no relative error exists  
between both values  
-9999 to 9999 (limited by output type)  
Control  
mode  
Type  
PID with automatic fuzzy self-tuning, PID, or ON/OFF  
0.1 to 999.9 °C/°F in units of 0.1 °C/°F  
0 to 3,999 seconds in 1-second units  
0 to 3,999 seconds in 1-second units  
Pulse output: 1 to 99 seconds in 1-second units  
500 ms  
Proportional band (P)  
Reset time (I)  
Rate time (D)  
Control period  
Sampling period  
Memory protection  
Non-volatile memory  
Other  
functions  
Input shift  
Offsets input value and display to accommodate a sensor input that deviates by a  
known value.  
Thermocouple range: -999 to 9999 °C/°F  
Platinum RTD range: -99.9 to 999.9 °C/°F  
Miscellaneous  
Present value  
Upper and lower set value limits, setting protection, Normal and Reverse output  
Indicators  
15 mm (0.59 in)  
red LED digits  
14 mm (0.55 in)  
red LED digits  
9.5 mm 0.37 in)  
green LED digits  
12 mm (0.47 in)  
red LED digits  
8 mm (0.32 in)  
green LED digits  
Set value  
10.5 mm (0.41 in)  
green LED digits  
LED indicators  
Other functions  
Note: 1. If control period is less than 5 seconds, use solid state relay or voltage relay.  
Note: 2. The E53-C3 Current Output Unit cannot be used if heater burnout alarm is used.  
3
E5J  
E5J  
Specifications, continued  
Materials  
Plastic case  
Mounting  
Fits 1/4 DIN panel cutouts, Fits 1/8 DIN panel  
Fits 1/16 DIN panel cutouts, includes  
includes two panel  
mounting brackets  
cutouts, includes two  
panel mounting brackets  
Y92F-30 panel mounting adapter  
Weight  
Controller  
Approx. 360 g (12.7 oz.)  
Approx. 280 g (9.9 oz.)  
Approx. 170 g (6.0 oz.)  
Adapter 10 g (0.35 oz.)  
Mounting hardware  
Brackets 65 g (2.3 oz.)  
Brackets 65 g (2.3 oz.)  
Connections  
Plated steel screw terminals mounted on rear of unit  
Enclosure  
ratings  
Front panel  
Rear case  
Terminals  
IEC IP54, NEMA 4 with optional Y92A covers (see note)  
IEC IP20  
IEC IP00  
Approvals  
UL  
Recognized, File number E68481  
Certified, File number LR59623  
-10° to 55° C (14° to 131°F)  
-25° to 65°C (-13° to 149°F)  
35 to 85% RH  
CSA  
Ambient  
Operating  
temperature Storage  
Humidity  
Insulation resistance  
Dielectric strength  
20 Mminimum at 500 VDC, measured with an output unit installed  
2,000 VAC, 50/60 Hz for 1 minutes between terminals of different polarities  
10 to 55 Hz, 19.6 m/s2 (2 G) in X, Y, and Z directions for 2 hours each  
10 to 55 Hz, 9.8 m/s2 (1 G) in X, Y, and Z directions for 10 minutes  
294 m/s2 (30 G) in 6 directions, 3 times each  
Vibration  
Mechanical durability  
Malfunction durability  
Mechanical durability  
Malfunction durability  
Shock  
196 m/s2 (20 G) in 6 directions, 3 times each  
Note:  
Optional NEMA 4 panel covers are available for E5–J controllers:  
Y92A-96N for E5AJ, Y92A-49N for E5EJ, and Y92A-48N for E5CJ  
CURRENT TRANSFORMERS FOR E5AJ, E5EJ, E5CJ2HB-F  
Part number  
E54-CT1  
E54-CT3  
Heater current  
Dielectric strength  
Vibration resistance  
Weight  
Maximum 50 A continuous service, single-phase  
1,000 VAC  
50 Hz (approx. 10 G)  
11.5 g (0.41 oz.)  
50 g (1.8 oz.)  
Accessories included  
2 contacts, 2 plugs  
COMMUNICATIONS FOR E5AJ, E5EJ  
Protocol  
RS-232C  
RS-422  
RS-485  
Transmission method  
Maximum cable length  
Synchronization method  
Baud rate  
4-wire half duplex  
15 m (49.2 ft)  
4-wire half duplex  
500 m (1,640 ft)  
2-wire half-duplex  
500 m (1,640 ft)  
Start-stop synchronization (asynchronous method)  
1,200/2,400/4,800/9,600/19,200 bps  
ASCII (7 bits)  
Transmission code  
Write to temperature controller  
Set point, alarm value, remote/local selection, proportional band, integral time, rate time (see note)  
Read from temperature controller Process value, output value, set point, alarm value, heater current value, initial status, proportional  
band, reset time, rate time, error codes, etc. (see note)  
System limits  
Peer to peer only  
A maximum of 32 controllers can be connected to one host  
computer in serial communication  
Note:  
If E5AJ is in ON/OFF control mode or PID control mode with fuzzy self-tuning, an undefined error will result if the proportional  
band, integral time, or derivative time command is transmitted.  
4
E5J  
E5J  
Dimensions  
Unit: mm (inch)  
109.7 (4.32)  
98 (3.86)  
96 x 96  
(3.78 x 3.78 )  
E5AJ  
11.7  
112  
(4.41)  
Side-by-side mounting of  
several controllers  
Recommended panel thickness is 1 to  
8 mm (0.04 to 0.32 in).  
Panel cutout  
91 x 91  
(3.58 x 3.58)  
92  
(3.62)  
92  
(3.62)  
120 (4.72)  
min.  
92  
(3.62)  
For side-by-side mounting:  
L = 96 mm x number of units - 3.5 mm  
(3.78 in x number of units - 0.14 in)  
E5EJ  
109.7 (4.32)  
98 (3.86)  
48  
(1.89)  
11.7  
96  
(3.78)  
112  
(4.41)  
Panel cutout  
Side-by-side mounting of  
several controllers  
45  
44 (1.73)  
(1.77)  
92  
(3.62)  
92  
(3.62)  
120 (4.72)  
min.  
91  
(3.58)  
For side-by-side mounting:  
L = 48 mm x number of units - 2.5 mm  
= (1.89 in x number of units - 0.10 in)  
Recommended panel thickness is 1 to  
8 mm (0.04 to 0.32 in).  
5
E5J  
E5J  
109.2 (4.30)  
100 (3.94)  
E5CJ  
9.2  
48 x 48  
(1.89 x 1.89)  
58  
(2.28)  
Side-by-side mounting of  
Panel cutout  
several controllers  
Recommended panel thickness is 1 to 4 mm  
(0.04 to 0.16 in).  
44.8 x 44.8  
(1.76 x 1.76)  
45  
(1.77)  
Mounting bracket Y92F-30 allows close  
side-by-side mounting.  
45  
(1.77)  
60 (2.36)  
min.  
45  
(1.77)  
For side-by-side mounting:  
L = 48 mm x number of units - 2.5 mm  
= (1.89 in x number of units - 0.10 in)  
6
E5J  
E5J  
Nomenclature  
E5EJ with communications  
E5AJ without communications  
1. Process value  
display  
2. Set value  
display  
11. Stop (STOP)  
indicator  
12. Remote (RMT)  
indicator  
3. Alarm output 1  
(ALM1) indicator  
10. Output (OUT)  
indicator  
4. Alarm output 2  
(ALM2) indicator  
9. Level key  
8. Mode key  
5. Heater burnout  
(HB) indicator  
6. Up key  
7. Down key  
E5CJ without communications  
1. Process value  
display  
2. Set value  
display  
10. Output (OUT)  
indicator  
3. Alarm output 1  
(ALM1) indicator  
9. Level key  
4. Alarm output 2  
(ALM2) indicator  
5. Heater burnout  
(HB) indicator  
6. Up key  
7. Down key  
8. Mode key  
Key Description  
Key Description  
1
Process value indicator displays the present  
temperature, parameter being set and error messages.  
Set value indicator displays the set values, messages and  
output value.  
7
Down key decrements the numeric value in the display.  
Pressed for 1 second or more, the display value deceases  
by 50 units in a second until the lower-limit value has been  
reached.  
2
8
9
Mode key changes the display mode within display levels.  
3
4
5
Indicator lights when alarm output 1 is turned ON.  
Level key changes the display level when depressed for at  
least 2 seconds.  
Indicator lights when alarm output 2 is turned ON.  
Heater burnout indicator lights when a heater burnout is  
detected and stays lit until reset.  
Up key increments the numeric value in the display.  
Pressed for 1 second or more, the set value increases by  
50 units in 1 second until the upper-limit value has been  
reached.  
10  
11  
Output indicator lights when the control output is ON. It  
does not light when the output selector switch is set for a  
current output.  
6
Stop indicator lights when the temperature controller is not  
in operation.  
12. Indicator lights when the controller is in remote (on-line)  
communication mode.  
Note:  
1. E5AJ and E5EJ models without communications have a Stop  
indicator.  
2. E5CJ-2HB models have all indicators shown. E5CJ-2 models  
have OUT, ALM1 and ALM2 indicators. E5CJ-models have OUT  
indicator only.  
7
E5J  
E5J  
Connections  
E5AJ, E5EJ CONTROLLERS  
For current  
output  
For voltage  
output  
For relay  
output  
RS-232C  
RS-422  
RS-485  
100 to 240 VAC,  
50/60 Hz  
Event 1*  
4 to 20 mA  
12 VDC, 40 mA  
Control output  
Event 2*  
Note:  
*
E5AJ/E5EJ models with communica-  
tions do not have an event input.  
** Alarm output 1 is ON when the E5AJ/  
E5EJ detects a sensor abnormality or  
heater burnout.  
Alarm output 2  
Use these terminals  
when connecting a  
platinum RTD.  
Use these terminals  
when connecting a  
thermocouple.  
Alarm output 1**  
E5CJ-2B CONTROLLERS  
Two Alarm Outputs, One Event Input, Heater Burnout Alarm  
For relay  
output  
For voltage  
output  
For current  
output  
12 VDC, 20 mA  
4 to 20 mA  
100 to 240 VAC,  
50/60 Hz  
Control output  
Event 1*  
Alarm  
output 1*  
Use these terminals  
when connecting a  
platinum RTD.  
CT  
Use these terminals  
when connecting a  
thermocouple.  
Alarm output 2  
Note:  
*
Alarm output 1 is ON when the E5AJ/  
E5EJ detects a sensor abnormality or  
heater burnout.  
8
E5J  
E5J  
E5CJ-2 CONTROLLERS  
Two Alarm Outputs, No Event Input  
For relay  
output  
For voltage  
output  
For current  
output  
4 to 20 mA  
12 VDC, 20 mA  
100 to 240 VAC,  
50/60 Hz  
Control output  
Alarm  
output 1  
Use these terminals  
when connecting a  
platinum RTD.  
Use these terminals  
when connecting a  
thermocouple.  
Alarm output 2  
E5CJ-CONTROLLERS  
No Alarm Outputs, No Event Input  
For voltage  
output  
For relay  
output  
For current  
output  
12 VDC, 20 mA  
4 to 20 mA  
100 to 240 VAC,  
50/60 Hz  
Control output  
Use these terminals  
when connecting a  
platinum RTD.  
Use these terminals  
when connecting a  
thermocouple.  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC TC12  
1/99  
Specifications subject to change without notice.  
Printed in the U.S.A.  

相关型号:

E5EK-AA2-500

Analog Circuit
OMRON

E5EN

Basic-type Digital Temperature Controller
OMRON

E5EN-C3ML-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3MT-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3MT-W-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3MTD-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3MTD-W-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3QMT-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-C3YMT-500-N

Basic-type Digital Temperature Controller
OMRON

E5EN-H

Advanced Digital Temperature Controller
OMRON

E5EN-HAA2HBM-500

Advanced Digital Temperature Controller
OMRON

E5EN-HAA2HBM-W-500

Advanced Digital Temperature Controller
OMRON