E5L-A100-200 [OMRON]

Electronic Thermostat E5L; 电子温控器E5L
E5L-A100-200
型号: E5L-A100-200
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Electronic Thermostat E5L
电子温控器E5L

电子
文件: 总12页 (文件大小:977K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
New Product  
Electronic Thermostat  
E5L  
Ideal for Simple Built-in Control.  
• A high switching capacity of 10 A at 250 VAC enables  
direct load switching.  
• A sensor is provided to enable immediate application.  
• Sockets with finger protection (PTF14A-E) or without  
finger protection (PTF14A) can be used.  
• Simple operation and settings. Even simpler with digital  
models.  
Model Number Structure  
Model Number Legend  
E5L-@@  
1 2  
1. Setting and Indication Methods  
A: Analog setting, no display  
C: Digital setting, display  
2. Set temperature  
30-20  
0-50  
:
:
:
30 to +20°C  
0 to +50°C  
0-100  
0 to +100°C  
100-200 : +100 to +200°C  
Ordering Information  
Electronic Thermostats  
E5L-A@  
Control  
output  
Size  
Type  
Control method  
Model  
E5L-A -30-20  
E5L-A 0-50  
45 × 35 mm  
Plug-in  
ON/OFF operation  
Relay  
E5L-A 0-100  
E5L-A 100-200  
E5L-C@  
Control  
output  
Size  
Type  
Control method  
Model  
E5L-C -30-20  
E5L-C 0-100  
E5L-C 100-200  
45 × 35 mm  
Plug-in  
ON/OFF operation  
Relay  
Note: The E5L-C is not available with a set temperature range of 0 to 50°C.  
Options (Order Separately)  
Sockets  
Type  
Model  
PTF14A  
PTF14A-E  
Front-connecting Socket  
1
E5L  
Ratings and Characteristics  
Ratings  
Item  
Power supply voltage  
Operating voltage range 85% to 110% of the rated supply voltage  
Model  
E5L-A@  
E5L-C@  
100 to 240 VAC, 50/60 Hz  
Power consumption  
Inputs  
Approx. 3 VA  
Element-interchangeable thermistor  
ON/OFF control  
Control method  
Control output  
Setting method  
Indication method  
SPDT contacts, 250 VAC, 10 A, cosφ = 1 (resistive load) SPST-NO contacts, 250 VAC, 10 A, cosφ = 1 (resistive load)  
Analog setting  
No display  
Digital settings using keys on front panel  
LCD digital display (character height: 12 mm)  
Setting protection (key protection)  
Input shift  
Direct/reverse operation  
Other functions  
Ambient temperature  
Ambient humidity  
10 to 55°C (with no icing or condensation)  
25% to 85%  
Storage temperature  
25°C to 65°C (with no icing or condensation)  
Note: Do not use the output from an Inverter as the power supply.  
Characteristics  
Item  
Model  
E5L-A@  
E5L-C@  
(1°C + 1 digit) max.*  
(1°C + 1 digit) max.*  
Indication accuracy  
Setting accuracy  
---  
---  
30 to 20°C models: Approx. 0.5 to 2.5°C (variable)  
0 to 50°C models: Approx. 0.5 to 4°C (variable)  
0 to 100°C models: Approx. 0.5 to 4°C (variable)  
100 to 200°C models: Approx. 0.7 to 4°C (variable)  
Hysteresis  
1 to 9°C (in increments of 1°C)  
Repeat accuracy  
1% FS max.  
---  
---  
Minimum scale  
(standard scale)  
30 to 20°C models and 0 to 50°C models: 5°C  
0 to 100°C models and 100 to 200°C models: 10°C  
Influence of temperature  
Influence of voltage  
Sampling period  
---  
((1% of PV or 2°C, whichever is greater) +1 digit) max.  
---  
---  
2 s  
Insulation resistance  
100 Mmax. (at 500 VDC)  
2,300 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, between power supply  
terminals and input terminals, between power supply terminals and output terminals, and between input terminals  
and output terminals)  
Dielectric strength  
Vibration (malfunction)  
Vibration (destruction)  
Shock (malfunction)  
Shock (destruction)  
Frequency of 10 to 55 Hz, 0.5-mm double amplitude for 10 min each in X, Y, and Z directions  
Frequency of 10 to 55-Hz, 0.75-mm double amplitude for 2 h each in X, Y, and Z directions  
147 m/s2, 3 times each in 6 directions  
294 m/s2, 3 times each in 6 directions  
100 m/s2, 3 times each in 6 directions  
Electrical life expectancy  
(control output relay)  
100,000 operations min (at maximum applicable load)  
Memory protection  
Weight (Thermostat)  
Degree of protection  
Approved standards  
Conformed standards  
---  
Approx. 80 g (Thermostat only)  
Front panel: IP40, Terminals: IP00  
Non-volatile memory (100,000 write operations)  
---  
EN 61010-1 (IEC 61010-1), Pollution Degree 2, Overvoltage Category II  
EMI:  
EN61326-1  
Radiated EMI:  
EN55011 Group1 ClassA  
EN55011 Group1 ClassA  
EN61326-1  
Conducted EMI:  
EMS:  
Electrostatic discharge immunity:  
Electromagnetic field strength immunity:  
Burst noise immunity:  
Conducted disturbance immunity:  
Surge immunity:  
EN61000-4-2  
EMC Directives  
EN61000-4-3  
EN61000-4-4  
EN61000-4-6  
EN61000-4-5  
Voltage dip and power interruption immunity: EN6100-4-11  
* The accuracy of the accessory thermistor is not included.  
2
E5L  
External Connections  
E5L-A@  
E5L-C@  
Control output*  
*
Control output  
250 VAC, 10 A  
250 VAC, 10 A  
Element-  
Element-  
interchangeable  
Thermistor  
interchangeable  
Thermistor  
Input power supply: 100 to 240 VAC  
* Control outputs: Terminals 8 and 12  
Input power supply: 100 to 240 VAC  
* Control output Heating load: Terminals 8 and 12  
Cooling load: Terminals 4 and 12  
Use the keys on the front panel to set direct/reverse operation.  
Be careful of the cooling load contacts, because they will be electrically  
charged even when the E5L input power supply is OFF.  
Note: For thermistor wiring, separate the input power supply and load lines as much as possible to avoid the influence of inductive noise.  
Nomenclature  
E5L-A@  
Operation Indicator  
Output status  
Operation  
indicator  
Heating load  
Cooling load  
OFF  
Lit red.  
Not lit.  
ON  
Hysteresis  
OFF  
ON  
adjuster (DIFF.)  
Operation indicator  
Temperature dial  
Operation Indicator: ON  
E5L-C@  
Output status  
Operation  
indicator  
Operation indicator  
Set value indicator  
Protection indicator  
Reverse  
Process value  
and set value  
display  
Direct operation  
operation  
Lit  
ON  
ON  
Not lit  
OFF  
OFF  
Set Value Indicator: SV  
Lit when the set value is displayed.  
Setting Protection Indicator:  
Lit when setting protection is set.  
Mode Key  
Down Key  
Up Key  
Dimensions  
Thermostats  
E5L-A@  
(Unit: mm)  
35  
(4.6)  
64  
6.4  
45  
75.0  
E5L-C@  
35  
64  
6.4  
45  
70.4  
3
E5L  
Wiring Connection Sockets (Order Separately)  
Terminal  
Arrangement and  
Internal Connections  
Mounting Hole  
Dimensions  
Dimensions  
PTF14A  
PTF14A-E Socket with Finger Protection  
(TOP VIEW)  
(TOP VIEW)  
Two, 4.5 x 6  
mounting holes  
Two, 4.5 x 6  
0.2  
0.2  
7
Note: Can be mounted to  
3.4  
3.4  
7
mounting holes  
a DIN Track.  
14, M3.5 x 8  
Sems screws  
14, M3.5 x 8  
Sems screws  
4
8
3
7
2
6
1
5
0.3  
78.5 max.  
35.4  
78.5 max.  
68  
35.5  
12 11 10  
14  
9
13  
0.2  
36  
45.5 max.  
8
30 max.  
45.5 max.  
8
33 max.  
Two, M4 or  
4.5-dia. holes  
Accessories  
E52-THE-E5L Element-interchangeable Thermistor  
Included with the following models: 30 to 20°C, 0 to 50°C, and 0 to  
100°C.  
Temperature Range  
Temperature  
range  
Color  
code  
Nominal  
resistance  
Thermistor  
Lead wires  
constant  
Color code  
PVC cable (12/0.18)  
(5.5-dia.)  
30 to 20°C  
0 to 100°C*  
Blue  
6 k(0°C)  
6 k(0°C)  
3,390 K  
3,390 K  
Heat-resistant  
PVC cable  
Black  
10  
0.55 kΩ  
(200°C)  
100 to 200  
°
C
Yellow  
4,300 K  
PTFE  
30  
30  
500  
Note: PVC cable is heat resistant from  
40 to 105  
40 to 250  
C applications.  
°
C.  
Included with 100 to 200°C Models.  
PTFE cable is heat resistant from  
°
°
C.  
* Use a 0 to 100  
°C thermistor for 0 to 50  
Color code  
PTFE cable (7/0.2)  
5-dia. max.  
Tolerance  
10  
Measured temperature  
30 to 100°C  
Tolerance  
2°C max.  
15  
60  
30  
500  
100 to 200°C  
Measured temperature 2% max.  
Mounting Brackets (Two)  
Temperature Sensors (Order Separately)  
E52-THE5A, E52-THE6D, and E52-THE6F Temperature Sensors can be ordered separately. For details, refer to an OMRON Web site.  
4
E5L  
Operating the E5L-C@  
Power ON  
Temperature Input Shift  
Direct/Reverse  
Operation  
Setting Protection  
Press the  
Press the  
Press the  
for at least 3 s.  
Key  
Press the  
Key  
and  
for at least 1 s.  
Keys  
and  
Keys  
for at least 3 s.  
for at least 1 s.  
Process value  
Set temperature  
display  
Process value  
display  
Press the  
Key for at least 3 s.  
Press the  
and  
Keys for at least 1 s.  
Control stops.  
Press the  
Key  
for less than 1 s.  
Set  
temperature  
Press the  
Key  
for less than 1 s.  
Hysteresis  
Press the  
Key  
for less than 1 s.  
Set temperature  
Setting the Temperature Input Shift  
1. Press the  
Key to enter the Set Temperature Mode.  
1. Press the  
Key for at least 3 s to enter the Temperature Input  
Shift Mode.  
2. Press the  
and Keys to set the temperature. The display  
will continue to change for as long as the key is held down.  
2. Press the  
and Keys to set the value. Each time the key is  
Note: The default setting is the lowest temperature in the range.  
pressed, the setting will change by 1°C. The setting will not  
continue to change as the key is held down. The key must be  
released after each change.  
Setting the Hysteresis  
The input shift can be set from 9 to 9°C, in increments of 1°C.  
1. Press the  
Key to enter the Hysteresis Mode.  
Note: 1. The default setting is 0°C.  
2. Press the  
and Keys to set the value. Each time the key is  
2. The control output turns OFF while this setting is being  
made.  
pressed, the setting will change by 1°C. The setting will not  
continue to change even if the key is held down. The key must be  
released after each change. The hysteresis can be set from 1 to  
9°C, in increments of 1°C.  
Tempera-  
ture dis-  
play  
Thermistormeasured  
Input shift display  
temperature  
Note: The default setting is 1°C.  
Hysteresis  
Display  
(No shift)  
25°C  
25°C  
34°C  
16°C  
+1°C  
(+9°C shift)  
(-9°C shift)  
25°C  
25°C  
+5°C  
+9°C  
Setting Direct or Reverse Operation  
Reverse Operation (Heating Control) Direct Operation (Cooling Control)  
1. Press the  
Selection Mode.  
2. Press the and  
Key for at least 3 s to enter the Direct/Reverse  
Hysteresis (1°C set)  
Hysteresis (1°C set)  
Power ON  
Power ON  
Keys to set the value. Direct operation can  
Key, and reverse operation can be set  
be set by pressing the  
by pressing the Key.  
OFF  
OFF  
Note: 1. The default setting is for reverse operation.  
2. The control output turns OFF while this setting is being  
made.  
Set temperature:  
65°C  
Set temperature  
example: -5°C  
Example:  
64°C  
4°C  
Direct/reverse operation  
Display  
Reverse operation  
Direct operation  
5
E5L  
Setting Protection  
1. Setting Protection (Process Value Display)  
Press the  
and  
Keys simultaneously while the process  
value is being displayed to change to the setting protection state.  
2. Setting Protection (Set Temperature Display)  
From the Setting Protection (process value display) Mode, press  
the  
and  
Keys simultaneously to change to the setting  
protection (set temperature display) state.  
3. From the Setting Protection (set temperature display) Mode, press  
the  
and  
Keys simultaneously to return to the process  
value display with no setting protection.  
Display example  
Display  
Process value display  
Set temperature display  
Note: 1. Setting protection disables key operations to prevent the  
settings from being changed accidentally.  
while protection is in effect.  
will be lit  
2. Protection will be maintained even when the power supply  
is turned OFF and ON.  
Error Displays and Causes  
E5L-A@  
When a thermistor disconnection occurs, the built-in relay operates at the OFF side (when NO contacts are used).  
NO contacts  
(Terminal numbers 8 and 12)  
* Heating load  
NC contacts  
(Terminal numbers 4 and 12)  
* Cooling load  
Thermistor  
Disconnection  
Short-circuit  
OFF  
OFF  
ON  
ON  
E5L-C@  
When an error occurs, the display shows the error code. Take the necessary measures, referring to the following table.  
Display  
Meaning  
Overflow  
Cause  
Control output  
Reverse operation: OFF  
Direct operation: ON  
The process value is higher than the set  
temperature range.  
FFF (lit)  
The process value is lower than the set  
temperature range  
Reverse operation: ON  
Direct operation: OFF  
--- (lit)  
Underflow  
Thermistor short-  
circuited  
Reverse operation: OFF  
Direct operation: OFF  
FFF (flashing)  
The thermistor is short-circuited.  
Thermistor  
disconnected  
Reverse operation: OFF  
Direct operation: OFF  
--- (flashing)  
E11 (lit)  
The thermistor is disconnected.  
The thermostat has failed.  
Memory error  
OFF  
Note: 1. Errors are not displayed while settings are being changed, except for memory errors. The control output status will be as shown in the  
above table while the set temperature or hysteresis is being set. The control output will be OFF while the temperature input shift or direct/  
reverse operation setting is being set. Key operations will be possible when an error occurs, except for a memory error.  
2. The setting protection indicator (  
) and set value indicator ("SV") will be continued even when settings are protected, except when a  
memory error occurs.  
6
E5L  
Safety Precautions  
CAUTION  
Precautions for Safe Use  
Do not touch the terminals while power is being supplied.  
Doing so may occasionally result in minor injury due to  
electric shock.  
Be sure to observe the following precautions to prevent failure to  
operate, malfunction, or adverse effects on the performance and  
functions of the Thermostat. Not doing so may occasionally result in  
unexpected events.  
1. The Product is designed for indoor use only.  
Do not use the Product outdoors or in any of the following  
locations.  
Do not allow pieces of metal, wire clippings, or fine metallic  
shavings or filings from installation to enter the Product.  
Doing so may occasionally result in electric shock, fire, or  
malfunction.  
Locations directly subject to heat radiated from heating  
equipment  
Locations subject to water or oil  
Locations subject to direct sunlight  
Locations subject to dust or corrosive gas (in particular, sulfide  
gas and ammonia gas)  
Do not use the Product where subject to flammable or  
explosive gas. Otherwise, minor injury from explosion may  
occasionally occur.  
Locations subject to sudden or extreme temperature changes  
Locations subject to icing or condensation  
Locations subject to vibration or shock  
Never disassemble, modify, or repair the Product or touch  
any of the internal parts. Minor electric shock, fire, or  
malfunction may occasionally occur.  
2. Use and store the Product within the rated temperature and  
humidity ranges. Provide forced cooling if required.  
3. To allow heat to escape, do not block the area around the  
Product.  
If the output relays are used past their life expectancy,  
contact fusing or burning may occasionally occur. Always  
consider the application conditions and use the output  
relays within their rated load and electrical life expectancy.  
The life expectancy of output relays varies considerably  
with the output load and switching conditions.  
4. Be sure to wire the Product properly with the correct terminal  
polarity.  
5. Use the specified size of crimped terminals for wiring (M3.5, width  
of 6.8 mm or less). To connect bare wires to the terminals, use  
copper wires with a gauge of AWG24 to AWG14 (equal to a  
cross-sectional area of 0.205 to 2.081 mm2). (The stripping length  
is 5 to 6 mm.) Do not connect more than two wires or two crimp  
terminals to one terminal. When connecting two wires, they must  
be of the same size and type.  
Tighten the terminal screws to between 0.74 and 0.90 N·m.  
Loose screws may occasionally result in fire.  
6. Do not connect anything to terminals that are not used.  
7. Allow as much space as possible between the Thermostat and  
devices that generate powerful high frequencies or surges.  
Separate the wiring to the Thermostat from high-voltage or high-  
current lines, and do not place the wiring to the Thermostat in  
parallel with or in the same wiring paths as power lines.  
8. Use this Product within the rated load and power supply  
specifications.  
Set the parameters and wiring of the Product so that they  
are suitable for the system being controlled. Unexpected  
operation may occasionally result in property damage or  
accidents.  
A malfunction in the Product may occasionally make  
control operations impossible or prevent alarm outputs,  
resulting in property damage. To maintain safety in the  
event of malfunction of the Product, take appropriate safety  
measures, such as installing a monitoring device on a  
separate line.  
9. Turn ON the power supply at least 30 minutes prior to starting  
control operations.  
10. A switch or circuit breaker must be provided close to the  
Thermostat. The switch or circuit breaker must be within easy  
reach of the operator, and must be marked as a disconnecting  
means for the Thermostat.  
11. Do not use paint thinner or similar solvents to clean the  
Thermostat. Use standard grade alcohol.  
12. Design the system (e.g., the control panel) considering the 2.5  
second of delay between turning ON the Thermostat and  
stabilization of the Thermostat's output.  
7
E5L  
Precautions for Correct Use  
Mounting the Thermostat  
1. Using the PTF14A Socket or PTF14A-E Socket with Finger  
Protection, mount the Thermostat to the bracket that is provided.  
(4.6)  
(4.6)  
(98.6)  
(98.6)  
E5L+PTF14A  
E5L+PTF14A-E  
2. The structure does not allow the case to be removed. Do not apply  
excessive force when mounting the Thermostat.  
Settings  
1. E5L-A@ Temperature Dial  
The temperature dial has some backlash. To adjust the  
temperature more accurately, turn the dial clockwise when  
adjusting the temperature.  
Do not change the setting of the temperature dial more than 20  
times.  
Do not attempt to turn the dial past the range of the setting scale.  
Applying excessive force may damage the Thermostat.  
2. E5L-A@ Hysteresis Dial  
This dial can be used to set hysteresis for the ON/OFF operation.  
Turn the dial clockwise to reduce the hysteresis and  
counterclockwise to increase the hysteresis. Increase the  
hysteresis to extend the life of the relay by preventing relay  
chattering caused by the control output turning ON and OFF  
frequently.  
Do not change the setting of the temperature dial more than 20  
times.  
Mounting the Thermistor  
Select a location for the temperature sensor of the thermistor  
where the temperature distribution of sensing objects will not be  
changed by installation.  
Insert the temperature sensor as far in as possible.  
When measuring fluid temperature, the thermistor should be  
installed against the current. Before mounting, take factors such as  
the bending moment of inertia and vibration into consideration.  
Do not apply mechanical force to the temperature-sensing part of  
the thermistor.  
The E52-THE@@ Thermistor can be used for applications that  
require metal protective tubing. Consult with your OMRON  
representative.  
Other Precautions  
Do not use the E5L-C@ if the front sheet is peeling or torn.  
Use appropriate tools to disassemble the Thermostat for disposal.  
8
MEMO  
9
MEMO  
10  
Warranty and Application Considerations  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or  
other period if specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,  
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER  
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET  
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,  
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON  
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE  
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,  
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE  
MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of  
products in the customer's application or use of the products.  
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will  
be used.  
Know and observe all prohibitions of use applicable to this product.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON  
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR  
SYSTEM.  
Disclaimers  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a  
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application  
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with  
your OMRON representative at any time to confirm actual specifications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
IL 60173-5302 U.S.A.  
OMRON Corporation  
Authorized Distributor:  
Industrial Automation Company  
Control Devices Division H.Q.  
Analog Controller Division  
Shiokoji Horikawa, Shimogyo-ku,  
Kyoto, 600-8530 Japan  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
OMRON ASIA PACIFIC PTE. LTD.  
Tel: (81) 75-344-7080/Fax: (81) 75-344-7149  
2-2-1 Nishikusatsu, Kusatsu-shi,  
Shiga, 525-0035 Japan  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark, Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  
Tel: (81) 77-565-5216/Fax: (81) 77-565-5568  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69-2132 JD Hoofddorp  
The Netherlands  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
© OMRON Corporation 2009 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
Printed in Japan  
0309 (0309)  
OMRON Industrial Automation Global: www.ia.omron.com  
Cat. No. H162-E1-01  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY