G2RL-1-E-HADC12 [OMRON]
Power/Signal Relay, SPDT, Momentary, 12VDC (Coil), 16A (Contact), 300VDC (Contact), AC/DC Output, Through Hole-Straight Mount,;型号: | G2RL-1-E-HADC12 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPDT, Momentary, 12VDC (Coil), 16A (Contact), 300VDC (Contact), AC/DC Output, Through Hole-Straight Mount, 光电二极管 继电器 |
文件: | 总6页 (文件大小:964K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G2RL
PCB Power Relay
Low Profile Power Relay
with 15.7 mm height, ideal for
incorporation in miniature
equipments
• A wide variety of single pole, double pole, high-capacity (16 A)
type and high-sensitivity type (250 mW) Relays are available.
• Low profile; 15.7 mm max. in height.
• Conforms to VDE (EN61810-1), UL508 and CSA22.2.
• IEC/EN 60335-1 conformed. (-HA Model)
• Satisfies ambient operating temperature requirement of 85°C
and 105°C (-CV Model).
• Clearance and creepage distance: 8 mm / 8 mm min.
• Coil insulation system: Class F (UL1446).
RoHS Compliant
■Model Number Legend
■Application Examples
• Home appliances
• OA equipments
G
2
R
L
G2RL-@@@-@-@-@
— — —
—
—
—
1 2 3
4
5
6
• Industrial machinery
1. Number of poles
4. Classification
None : Standard
1
: 1 pole
2
: 2 pole
E
H
: High-capacity
: High-sensitivity
2. Contact Form
None : SPDT (1c)
5. Special Requirement
A
: SPST-NO (1a)
None : Standard
CV : 16 A, pinning 5 mm,: switching at 105°C
3. Enclosure rating
None : Flux protection
6. Market Code
4
: Sealed
None : General purpose
HA : Home Appliance according to IEC/EN60335-1
■Ordering Information
Terminal Shape
Market Code
Classification
Standard
Contact form
Enclosure rating
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Flux protection
Sealed
Model
G2RL-1A
G2RL-1A4
G2RL-1
G2RL-14
G2RL-2A
G2RL-2A4
G2RL-2
G2RL-24
G2RL-1A-E
G2RL-1A4-E
G2RL-1-E
G2RL-14-E
G2RL-1A-E-CV
G2RL-1A-H
G2RL-1-H
Rated coil voltage Minimum packing unit
SPST-NO (1a)
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
5 VDC
12 VDC
24 VDC
48 VDC
General
purpose
SPST-NO (1a)
SPDT (1c)
PCB terminals
20 pcs/tube
High-capacity
SPST-NO (1a)
High-sensitivity
Standard
SPDT (1c)
DPST-NO (2a)
DPDT (2c)
SPST-NO (1a)
SPDT (1c)
12 VDC
24 VDC
Flux protection
G2RL-2A-HA
G2RL-2-HA
G2RL-1A-E-HA
G2RL-1-E-HA
Home
Appliance
High-capacity
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A DC5
Rated coil voltage
However, the notation of the coil voltage on the product case will be marked as @@VDC.
Note 2. Place your order in tube (20 pcs/tube) units.
Note 3. Contact your OMRON sales representative for sealed models.
1
G2RL
PCB Power Relay
■Ratings
●Coil
Item
Must operate voltage Must release voltage
Max. voltage
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(V)
(V)
(V)
(Ω)
Rated voltage
% of rated voltage
5 VDC
12 VDC
24 VDC
48 VDC
12 VDC
24 VDC
80.0
33.3
16.7
8.96
20.8
10.42
62.5
360
1,440
5,358
576
Approx. 400
Standard
70% max.
75% max.
130%
(at 85°C)
10% min.
Approx. 430
Approx. 250
High-
sensitivity
2,304
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
Classification
Model
Standard type (resistive load)
High-capacity type (resistive load) High-sensitivity type (resistive load)
G2RL-1A-E (-CV) G2RL-1-E G2RL-1A-H G2RL-1-H
Single
Ag-alloy (Cd free)
16 A at 250 VAC
Item
G2RL-1A
G2RL-1
G2RL-2A
G2RL-2
Contact type
Contact material
12 A at 250 VAC
8 A at 250 VAC
Rated load
10 A at 250 VAC (See note)
12 A at 24 VDC (See note)
8 A at 30 VDC (See note)
16 A at 24 VDC (See note)
8 A (70°C)/5 A (85°C) (See
note)
Rated carry current
12 A (See note)
16 A (See note)
10 A (See note)
Max. switching voltage
Max. switching current
440 VAC, 300 VDC
G
2
R
L
12 A
8 A
16 A
10 A
Failure rate (P level)
(reference value*)
40 mA at 24 VDC
*
This value was measured at a switching frequency of 120 operations/min.
Note: Contact your OMRON representative for the ratings on sealed models.
■Characteristics
Classification
Standard type
High-capacity type
High-sensitivity type
Item
Number of poles
1-pole
2-pole
1-pole
Contact resistance *1
Operate (set) time
100 mΩ max.
15 ms max.
Release (reset) time
Insulation resistance *2
5 ms max.
1,000 M
Ω min.
Between coil and
contacts
5,000 VAC, 50/60 Hz for 1min
Between contacts
of the same
polarity
Dielectric
strength
1,000 VAC, 50/60 Hz for 1min
Between contacts
of different polarity
Impulse withstand voltage
−
2,500 VAC, 50/60 Hz for 1min
10 kV (1.2 x 50 μs)
−
Destruction
Malfunction
Destruction
Malfunction
Mechanical
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
Vibration
resistance
Shock
resistance
Energized: 100 m/s2, De-energized: 100 m/s2
20,000,000 operations (at 18,000 operations/hr)
G2RL-1(A)-E:
30,000 operations at 250 VAC, 16 A
30,000 operations at 24 VDC, 16 A G2RL-1(A)-H:
G2RL-1A-E-CV:
50,000 operations at 250 VAC, 16 A
at 105°C
G2RL-1(A):
50,000 operations at 250 VAC, 12 A
30,000 operations at 24 VDC, 12 A
G2RL-2(A):
30,000 operations at 250 VAC, 8 A
30,000 operations at 30 VDC, 8 A
Durability
Electrical *3
(resistive load)
50,000 operations at 250 VAC, 10 A
-40°C to 85°C (with no icing or condensation)
Ambient operating temperature
-40°C to 105°C (with no icing or condensation) by G2RL-1A-E-CV
5% to 85% (with no icing or condensation)
Approx. 12 g
Ambient operating humidity
Weight
Note. Values in the above table are the initial values at 23°C.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric strength using a 500 VDC ohmmeter.
*3. 1,800 operations per hour.
2
G2RL
PCB Power Relay
■Engineering Data
●Maximum Switching Capacity
G2RL-1A, G2RL-1
G2RL-1A-E, G2RL-1-E
G2RL-2A, G2RL-2
50
50
50
AC resistive load
AC resistive load
AC resistive load
10
5
10
5
10
5
DC resistive
load
DC resistive
load
DC resistive
load
1
1
1
0.5
0.5
0.5
0.1
0.1
0.1
0
5
10 20 30 50 100
5001,000
0
5
10 20 30 50 100
5001,000
0
5
10 20 30 50 100
5001,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
●High-sensitivity type
●Ambient Temperature vs. Rated
●Ambient Temperature vs. Maximum
G2RL-1A-H, G2RL-1-H
Carry Current
Coil Voltage
20
250
50
G2RL-1A-E, G2RL-1-E
AC resistive load
16
15
200
G
2
R
L
10
5
180
G2RL-1A, G2RL-1
G2RL-1A-E-CV
12
150
130
DC resistive
G2RL-1A-H, G2RL-1-H
10
load
110
100
8
1
Other type
G2RL-2A, G2RL-2
5
0.5
50
0.1
0
10 20 30 40 50 60 70
8085 90 100 105 110
0
10 20 30 40 50 60 70 80 85 90 100
Ambient temperature (°C)
0
5
10 20 30 50 100
5001,000
Ambient temperature (°C)
Switching voltage (V)
Note. The maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
●Ambient Temperature vs. Must
Operate and Must Release Voltages
100
Sample:
G2RL-14-E 24 VDC
Number of relays: 5 pcs
Must operate voltage
Must release voltage
90
80
70
60
50
40
30
20
10
max.
X
min.
max.
X
min.
0
20
40
60
80
100 120
Ambient temperature (°C)
3
G2RL
PCB Power Relay
●Shock Malfunction
G2RL-1 (A)-E
G2RL-2 (A)
Y
1,000
Y
1,000
NO contact
NO contact
Sample: G2RL-14 12 VDC
Number of Relays: 5 pcs
Test conditions: Shock is applied
in ±±, ±ꢀ, and ±ꢁ directions three
times each with without energizing
the Relays to check the number of
malfunctions.
Sample: G2RL-24 12 VDC
Number of Relays: 5 pcs
Test conditions: Shock is applied
in ±±, ±ꢀ, and ±ꢁ directions three
times each with without energizing
the Relays to check the number of
malfunctions.
X'
1,000
Z
X'
1,000
Z
1,000
1,000
150
130
Requirement: None malfuction
Requirement: None malfuction
1,000
X
1,000
X
1,000
100 m/s2
1,000
Z'
100 m/s2
NC contact
NC contact
Z'
Shock direction
Shock direction
X
X'
X
X'
Y
Y
Z
Z
1,000
Y'
1,000
Y'
Unit: m/s2
Unit: m/s2
Z'
Z'
Y'
Y'
■Electrical Endurance Data (Reference Value)
8 A 250 VAC (cosφ=0.4) 200,000 operation min. (N.O.)
G2RL-1-E
8 A 30 VDC (L/R=7 ms)
10,000 operation min. (N.O.)
5 A 250 VAC (cosφ=0.4) 150,000 operation min. (N.O.)
G2RL-1
5 A 30 VDC (L/R=7 ms)
10,000 operation min. (N.O.)
8 A 250 VAC (cosφ=1)
30,000 operation min.
10,000 operation min.
G
2
R
L
G2RL-2
8 A 30 VDC
Pilot duty (A300), 250 VAC 250,000 operation min.
Pilot duty (A300), 125 VAC 150,000 operation min.
G2RL-1A-E
Note. The results shown reflect values at ambient temperature 23°C. Electrical endurance will vary depending on the test conditions.
Contact your OMRON representative if you require more detailed information for the electrical endurance under your test condition.
■Dimensions (Unit: mm)
G2RL-1A, G2RL-1A4, G2RL-1A-H
PCB Mounting Holes
(Bottom View)
3.5
Terminal Arrangement/
Internal Connections
(Bottom View)
Four, 1.3-dia. holes
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
3
7.5
15.7 max.
(15.5)*
5
4
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
* Average value
G2RL-1, G2RL-14, G2RL-1-H
PCB Mounting Holes
(Bottom View)
3.5 3.5
Terminal Arrangement/
Internal Connections
(Bottom View)
Five, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
2
3
7.5
15.7 max.
(15.5)*
5
4
(2.3)
20
(No coil polarity)
0.5
0.5
0.8
3.5
0.5
0.5
* Average value
G2RL-1A-E (-HA), G2RL-1A4-E, G2RL-1A-E-CV
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
5
Six, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
3
4
7.5
15.7 max.
(15.5)*
6
5
8(No coil polarity)
(2.3)
20
0.5
0.5
0.8
3.5
0.5
* Average value
4
G2RL
PCB Power Relay
G2RL-1-E (-HA), G2RL-14-E
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
Eight, 1.3-dia. holes (Bottom View)
5
5
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
2
3
4
5
7.5
15.7 max.
(15.5)*
8
7
6
(2.3)
20
(No coil polarity)
0.5
0.5
0.5
0.5
0.8
0.8
0.8
3.5
0.5
0.5
0.5
0.5
* Average value
G2RL-2A (-HA), G2R-2A4
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
5
Six, 1.3-dia. holes
(2.5)
12.7 max.
(12.5)*
29 max.
(28.8)*
1
3
4
7.5
15.7 max.
(15.5)*
8
6
5
(2.3)
20
(No coil polarity)
0.5
3.5
* Average value
G2RL-2 (-HA), G2R-24
G
2
R
L
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
Eight, 1.3-dia. holes (Bottom View)
5
5
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
1
2
3
4
5
7.5
15.7 max.
(15.5)*
8
7
6
(2.3)
20
(No coil polarity)
0.5
3.5
0.5
* Average value
■Approved Standards
• The approval rating values for overseas standards are different from the performance values determined individually. Confirm
the values before use.
UL Recognized:
CSA Certified:
(File No. 41643)
(File No. LR31928)
Number of test
operations
Model
Contact form
Coil ratings
Contact ratings
G2RL-1A
SPST-NO (1a)
12 A, 250 VAC (General Use) 40°C
12 A, 24 VDC (Resistive) 40°C
16 A, 250 VAC (General Use) 40°C
16 A, 24 VDC (Resistive) 40°C
16 A, 250 VAC (Resistive) 105°C
10 A, 250 VAC (General Use) 40°C
10 A, 24 VDC (Resistive) 40°C
100,000
50,000
G2RL-1
SPDT (1c)
G2RL-1A-E (-HA)
G2RL-1-E (-HA)
G2RL-1A-E-CV
G2RL-1A-H
SPST-NO (1a)
SPDT (1c)
100,000
50,000
SPST-NO (1a)
SPST-NO (1a)
SPDT (1c)
3 to 48 VDC
100,000
50,000
G2RL-1-H
G2RL-2A (-HA)
G2RL-2 (-HA)
DPST-NO (2a)
DPDT (2c)
8 A, 277 VAC (General Use) 40°C
8 A, 30 VDC (Resistive) 40°C
100,000
5
G2RL
EN/IEC, VDE Certified
PCB Power Relay
(Certificate No. 119650)
Number of test
operations
Model
G2RL-1A
Contact form
SPST-NO (1a)
SPDT (1c)
Coil ratings
Contact ratings
12 A, 250 VAC (cos
φ=1) 85°C
12 A, 24 VDC (L/R=0 ms) 85°C
100,000
6,000
AC15: 3 A at 240 VAC at room temperature
DC13: 2.5 A at 24 VDC, 50ms at room temperature
G2RL-1
16 A, 250 VAC (cos
φ
=1) 85°C
30,000
15,000
G2RL-1A-E (-HA)
SPST-NO (1a)
16 A, 24 VDC (L/R=0 ms) 85°C
AC15: 3 A at 240 VAC (NO) at room temperature,
1.5 A at 240V AC (NC) at room temperature
DC13: 2.5 A at 24 VDC (NO), 50ms at room temperature
G2RL-1-E (-HA)
G2RL-1A-E-CV
SPDT (1c)
6,000
3 to 48 VDC
SPST-NO (1a)
16 A, 250 VAC (cos
10 A, 250 VAC (cos
10 A, 250 VAC (cos
φ=1) 105°C
φ=1) 85°C
φ=1) 40°C
100,000
50,000
100,000
50,000
30,000
15,000
G2RL-1A-H
G2RL-1-H
SPST-NO (1a)
SPDT (1c)
10 A, 24 VDC (L/R=0 ms) 85°C
8 A, 250 VAC (cos =1) 85°C
φ
G2RL-2A (-HA)
G2RL-2 (-HA)
DPST-NO (2a)
DPDT (2c)
8 A, 30 VDC (L/R=0 ms) 85°C
AC15: 1.5 A at 240VAC at room temperature
DC13: 2 A at 30 VDC, 50ms at room temperature
6,000
Creepage distance
8 mm min.
8 mm min.
IIIa
Clearance distance
Insulation material group
Type of insulation coil-contact circuit
open contact circuit
Reinforced
Micro disconnection
G
2
R
L
Rated Insulation voltage
Pollution degree
250 V
3 (Flux protection / Sealed)
250 V / 400 V (Flux protection)
III
Rated voltage system
Over voltage category
Category of protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed)
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
Glow wire according to IEC 60335-1
Tracking Index of relay base
PTI 250 V min. (housing parts)
■Precautions
• Please refer to “PCB Relays Common Precautions” for correct use.
● Cleaning
Correct Use
• The G2RL model is flux-resistant with two sealing holes on the
case. Thus, do not clean the Relay by boiling or soaking in
water. Consult your Omron sales representative for sealed
type Relay.
● Mounting Position Compared to G2R Model
• Although the G2RL model and the G2R model are both low
profile Relays, their characteristics such as switching capacity
are different. Be sure to check operation under the actual
operating conditions before use.
●
Using Relays in an Atmosphere Containing Corrosive Gas
• Do not use Relays in an atmosphere containing corrosive gas
(sulfuric or organic gas).Otherwise, connection failure due to
corrosion on the contact surface may lead to functional faults.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J117-E1-09
0316(0207)(O)
6
相关型号:
G2RL-1-E12VDC
Power/Signal Relay, SPDT, Momentary, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-1-E24VDC
Power/Signal Relay, SPDT, Momentary, 0.17A (Coil), 24VDC (Coil), 400mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-1-EDC48
Power/Signal Relay, SPDT, Momentary, 0.009A (Coil), 48VDC (Coil), 430mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-1-EDC5
Power/Signal Relay, SPDT, Momentary, 0.08A (Coil), 5VDC (Coil), 400mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-1-HDC5
Power/Signal Relay, SPDT, Momentary, 0.05A (Coil), 5VDC (Coil), 250mW (Coil), 10A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-14-12VDC
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.033A (COIL), 12VDC (COIL), 400mW (COIL), 12A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON
G2RL-14-5VDC
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.08A (COIL), 5VDC (COIL), 400mW (COIL), 12A (CONTACT), 24VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明