G2RL-1-E12VDC [OMRON]

Power/Signal Relay, SPDT, Momentary, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
G2RL-1-E12VDC
型号: G2RL-1-E12VDC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, SPDT, Momentary, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 16A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总5页 (文件大小:376K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PCB Relay  
G2RL  
A Power Relay with Various Models  
High-sensitivity (250 mW) and High-capacity  
(16 A) Models available.  
Low profile: 15.7 mm max. in height  
Conforms to VDE (EN61810-1), UL508 and  
CSA22.2.  
Meets EN60335-1 requirements for household  
products.  
Clearance and creepage distance: 10 mm/10 mm.  
Tracking resistance: CTI>250  
Coil Insulation system: Class F (UL1446)  
RoHS Compliant  
Ordering Information  
Classification  
Enclosure  
ratings  
Contact form  
SPDT DPST-NO  
G2RL-1 G2RL-2A  
SPST-NO  
G2RL-1A  
DPDT  
General-purpose  
Flux protection  
Fully sealed  
G2RL-2  
G2RL-1A4  
G2RL-14  
G2RL-2A4  
G2RL-24  
High-capacity  
Flux protection  
Fully sealed  
G2RL-1A-E  
G2RL-1A4-E  
G2RL-1A-H  
G2RL-1-E  
G2RL-14-E  
G2RL-1-H  
---  
---  
---  
---  
---  
---  
High-sensitivity  
Flux protection  
Note: When ordering, add the rated coil voltage to the model number.  
Example: G2RL-1A 12 VDC  
Rated coil voltage  
Model Number Legend  
G2RL-@@@-@  
1
2
3
4
1. Number of Poles  
1: 1 pole  
4. Classification  
None: General purpose  
2: 2 poles  
2. Contact Form  
None: @PDT  
E:  
H:  
High capacity (1 pole)  
High sensitivity (1 pole)  
A:  
@PST-NO  
3. Enclosure Ratings  
None: Flux protection  
4:  
Fully sealed  
Specifications  
Coils Ratings for General-purpose and High-capacity Models  
Rated voltage  
5 VDC  
80.0 mA  
62.5  
12 VDC  
33.3 mA  
360 Ω  
24 VDC  
16.7 mA  
1,440 Ω  
48 VDC  
8.96 mA  
5,358 Ω  
Rated current  
Coil resistance  
Must operate voltage  
Must release voltage  
Max. voltage  
70% max. of the rated voltage  
10% min. of the rated voltage  
180% of rated voltage (at 23°C)  
Approx. 400 mW  
Power consumption  
Approx. 430 mW  
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.  
1
G2RL  
G2RL  
Coils Ratings for High-sensitivity Models  
Rated voltage  
5 VDC  
50.0 mA  
100  
12 VDC  
20.8 mA  
576 Ω  
24 VDC  
10.42 mA  
2,304 Ω  
Rated current  
Coil resistance  
Must operate voltage  
Must release voltage  
Max. voltage  
75% max. of the rated voltage  
10% min. of the rated voltage  
180% of rated voltage (at 23°C)  
Approx. 250 mW  
Power consumption  
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.  
Contact Ratings  
Item  
Number of poles  
Contact material  
Load  
General-purpose Models  
High-capacity Models  
High-sensitivity Models  
1 pole  
2 poles  
1 pole  
1 pole  
Ag Alloy (Cd free)  
Resistive load (cosφ=1)  
Rated load  
12 A at 250 VAC  
12 A at 24 VDC (See  
note.)  
8 A at 250 VAC  
16 A at 250 VAC  
10 A at 250 VAC  
8 A at 30 VDC (See note.) 16 A at 24 VDC (See note.) 10 A at 24 VDC  
(See note.)  
Rated carry current  
12 A (See note.)  
8 A (70°C)/5 A (85°C)  
16 A (See note.)  
10 A (See note.)  
(See note.)  
Max. switching voltage 440 VAC, 300 VDC  
Max. switching current 12 A  
8 A  
16 A  
10 A  
Max. switching power  
3,000 VA  
2,000 VA  
4,000 VA  
2,500 VA  
Note: Contact your OMRON representative for the ratings on fully sealed models.  
Characteristics  
Item  
General-purpose  
General-purpose Models  
2 pole  
High-sensitivity Models  
(High-capacity) Models  
Number of poles  
1 pole  
1 pole  
Contact resistance  
Operate (set) time  
Release (reset) time  
100 mmax.  
15 ms max.  
5 ms max.  
Max. operating frequency Mechanical:18,000 operation/hr  
Electrical:1,800 operation/hr at rated load  
Insulation resistance  
Dielectric strength  
1,000 Mmin. (at 500 VDC)  
5,000 VAC, 1 min between coil and 5,000 VAC, 1 min between coil and 5,000 VAC, 1 min between coil and  
contacts  
1,000 VAC, 1 min between con-  
tacts of same polarity  
contacts  
contacts  
2,500 VAC, 1 min between contacts 1,000 VAC, 1 min between con-  
of different polarity  
1,000 VAC, 1 min between contacts  
of same polarity  
tacts of same polarity  
Impulse withstand voltage 10 kV (1.2×50 µs) between coil and contact  
Vibration resistance  
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
Shock resistance  
Destruction: 1,000 m/s2 (approx. 100 G)  
Malfunction: 100 m/s2 (approx. 10 G)  
Endurance (Mechanical)  
Ambient temperature  
20,000,000 operations (at 18,000 operations/hr)  
Operating:  
Storage:  
–40°C to 85°C (with no icing)  
–40°C to 85°C (with no icing)  
Ambient humidity  
Weight  
5% to 85%  
Approx. 12 g  
Note: Values in the above table are the initial values.  
Approved Standards  
UL508 (File No. E41643)/CSA C22.2 (No. 14) (File No. LR31928)  
Model  
Contact form  
Coil ratings  
Contact ratings  
G2RL-1A  
G2RL-1  
SPST-NO  
SPDT  
3 to 48 VDC  
12 A at 250 VAC (General use)  
12 A at 24 VDC (Resistive)  
G2RL-1A-E  
G2RL-1-E  
G2RL-1A-H  
G2RL-1-H  
G2RL-2A  
G2RL-2  
SPST-NO  
SPDT  
16 A at 250 VAC (General use)  
16 A at 24 VDC (Resistive)  
SPST-NO  
SPDT  
5 to 24 VDC  
3 to 48 VDC  
10 A at 250 VAC (General use)  
10 A at 24 VDC (Resistive)  
DPST-NO  
DPDT  
8 A at 277 VAC (General use)  
8 A at 30 VDC (Resistive)  
2
G2RL  
G2RL  
VDE (EN61810-1) (License No. 119650)  
Model  
Contact form  
Coil ratings  
Contact ratings  
G2RL-1(A)  
1 pole  
5, 12, 18, 22, 24, 48 VDC  
12 A at 250 VAC (cosφ=1)  
12 A at 24 VDC (L/R=0 ms)  
AC15: 3 A at 240 VAC  
DC13: 2.5 A at 24 VDC, 50 ms  
G2RL-1(A)-E  
1 pole  
5, 12, 18, 22, 24, 48 VDC  
16 A at 250 VAC (cosφ=1)  
16 A at 24 VDC (L/R=0 ms)  
AC15: 3 A at 240 VAC (NO)  
1.5 A at 240 VAC (NC)  
DC13: 2.5 A at 24 VDC (NO), 50 ms  
G2RL-1(A)-H  
G2RL-2(A)  
1 pole  
5, 9, 12, 24 VDC  
10 A at 250 VAC (cosφ=1)  
10 A at 24 VDC (L/R=0 ms)  
2 poles  
5, 12, 18, 22, 24, 48 VDC  
8 A at 250 VAC (cosφ=1)  
8 A at 24 VDC (L/R=0 ms)  
AC15: 1.5 A at 240 VAC  
DC13: 2 A at 30 VDC, 50 ms  
Engineering Data  
Maximum Switching Capacity  
G2RL-1A, G2RL-1  
G2RL-1A-E, G2RL-1-E  
G2RL-2A, G2RL-2  
50  
50  
50  
AC resistive load  
AC resistive load  
AC resistive load  
10  
10  
5
10  
5
DC resistive  
load  
5
DC resistive  
load  
DC resistive  
load  
1
1
1
0.5  
0.5  
0.5  
0.1  
0.1  
0.1  
0
5
10 20 30 50 100  
5001,000  
0
5
10 20 30 50 100  
5001,000  
0
5
10 20 30 50 100  
5001,000  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
Ambient Temperature  
vs Rated Carry Current  
Ambient Temperature  
vs Maximum Coil Voltage  
250  
G2RL-1A-H, G2RL-1-H  
G2RL-1A-E, G2RL-1-E  
AC resistive load  
200  
180  
G2RL-1A, G2RL-1  
150  
130  
DC resistive  
load  
G2RL-1A-H, G2RL-1-H  
G2RL-2A, G2RL-2  
100  
50  
0
10 20 30 40 50 60 70 80 85 90 100  
Ambient temperature (°C)  
Switching voltage (V)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the maximum  
value in a varying range of operating power  
voltage, not a continuous voltage.  
Ambient Temperature vs  
Must Operate and  
Must Release Voltages  
100  
Sample: G2RL-14-E 24 VDC  
Quantity: 5  
Must operate voltage  
Must release voltage  
90  
80  
70  
60  
50  
40  
30  
20  
10  
max.  
min.  
max.  
min.  
0
20  
40  
60  
80  
100 120  
Ambient temperature (°C)  
3
G2RL  
G2RL  
Shock Malfunction  
G2RL-1 (A)-E  
G2RL-2 (A)  
Y
Y
1,000  
1,000  
NO contact  
NO contact  
Sample:  
G2RL-14 DC12V  
Sample:  
G2RL-24 DC12V  
Number of Relays: 5pcs  
Number of Relays: 5pcs  
Conditions: Shock is applied in X, Y, Z  
X'  
1,000  
Z
X'  
1,000  
Z
Conditions:  
Shock is applied in X, Y,  
directions three times each  
Z
1,000  
1,000  
directions three times each  
with and without energizing the  
Relays to check the number of  
malfunctions.  
with and without energizing the  
Relays to check the number of  
malfunctions.  
150  
130  
Requirement:  
None malfunction 100m/s2  
Requirement:  
None malfunction 100m/s2  
1,000  
X
1,000  
Z'  
1,000  
X
1,000  
NC contact  
NC contact  
Z'  
Shock direction  
Shock direction  
X
Y
X'  
X
X'  
Y
Z
Z
1,000  
Unit: m/s2  
1,000  
Y'  
Unit: m/s2  
Y'  
Z'  
Z'  
Y'  
Y'  
Electrical Endurance Data  
G2RL-1-E  
16 A at 250 VAC (cosφ=1)  
30,000 operations min.  
30,000 operations min.  
200,000 operation min. (normally open side operation)  
10,000 operation min. (normally open side operation)  
16 A at 24 VDC  
8 A at 250 VAC (cosφ=0.4)  
8 A at 30 VDC (L/R=7 ms)  
G2RL-1  
12 A at 250 VAC (cosφ=1)  
12 A at 24 VDC  
50,000 operations min.  
30,000 operations min.  
5 A at 250 VAC (cosφ=0.4)  
150,000 operation min. (normally open side operation)  
20,000 operation min. (normally open side operation)  
5 A at 30 VDC (L/R=7 ms)  
G2RL-1-H  
G2RL-2  
10 A at 250 VAC (cosφ=1)  
100,000 operations min.  
50,000 operations min.  
10 A at 24 VDC  
8 A at 250 VAC (cosφ=1)  
30,000 operations min.  
30,000 operations min.  
8 A at 30 VDC  
Note: The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.  
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the  
electrical endurance under your test conditions.  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
G2RL-1A(-H), G2RL-1A4  
(Bottom View)  
Four, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
3.5  
29 max.  
(28.8)*  
(2.5)  
1
3
7.5  
15.7 max.  
(15.5)*  
4
5
(2.3)  
20  
* Indicates average dimensions.  
0.8  
0.5  
0.5  
0.5  
3.5  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
G2RL-1(-H), G2RL-14  
(Bottom View)  
Five, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
3.53.5  
29 max.  
(28.8)*  
2
1
3
(2.5)  
7.5  
15.7 max.  
(15.5)*  
5
4
(2.3)  
20  
* Indicates average dimensions.  
0.8  
0.5  
0.5  
0.5  
3.5  
0.5  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
(Bottom View)  
5
G2RL-1A-E, G2RL-1A4-E  
Six, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
29 max.  
(28.8)*  
(2.5)  
3
4
1
7.5  
15.7 max.  
(15.5)*  
6
5
8
(2.3)  
20  
* Indicates average dimensions.  
0.8  
0.5  
0.5  
0.5  
3.5  
4
G2RL  
G2RL  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
(Bottom View)  
G2RL-1-E, G2RL-14-E  
Eight, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
5
5
29 max.  
(28.8)*  
(2.5)  
1
4
2
3
7.5  
15.7 max.  
(15.5)*  
6
8
7
5
(2.3)  
20  
0.8  
0.5  
0.5  
0.5  
* Indicates average dimensions.  
3.5  
0.5  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
(Bottom View)  
5
G2RL-2A, G2RL-2A4  
G2RL-2, G2RL-24  
Six, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
29 max.  
(28.8)*  
(2.5)  
4
3
1
8
7.5  
15.7 max.  
(15.5)*  
6
5
20  
(2.3)  
0.8 * Indicates average dimensions.  
0.5  
0.5  
0.5  
3.5  
Terminal Arrangement/  
Internal Connection  
(Bottom View)  
Mounting Holes  
(Bottom View)  
Eight, 1.3 0.1 dia.  
holes  
12.7 max.  
(12.5)*  
5
5
29 max.  
(28.8)*  
(2.5)  
2
4
1
3
7.5  
15.7 max.  
(15.5)*  
5
8
7
6
(2.3)  
20  
* Indicates average dimensions.  
0.8  
0.5  
0.5  
0.5  
3.5  
0.5  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
Cat. No. X033-E1-14A  
In the interest of product improvement, specifications are subject to change without notice.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY