G2RL-1A5VDC [OMRON]
Power/Signal Relay, SPST, Momentary, 0.08A (Coil), 5VDC (Coil), 400mW (Coil), 12A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;型号: | G2RL-1A5VDC |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPST, Momentary, 0.08A (Coil), 5VDC (Coil), 400mW (Coil), 12A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT 继电器 |
文件: | 总5页 (文件大小:376K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PCB Relay
G2RL
A Power Relay with Various Models
■ High-sensitivity (250 mW) and High-capacity
(16 A) Models available.
■ Low profile: 15.7 mm max. in height
■ Conforms to VDE (EN61810-1), UL508 and
CSA22.2.
■ Meets EN60335-1 requirements for household
products.
■ Clearance and creepage distance: 10 mm/10 mm.
■ Tracking resistance: CTI>250
■ Coil Insulation system: Class F (UL1446)
RoHS Compliant
Ordering Information
Classification
Enclosure
ratings
Contact form
SPDT DPST-NO
G2RL-1 G2RL-2A
SPST-NO
G2RL-1A
DPDT
General-purpose
Flux protection
Fully sealed
G2RL-2
G2RL-1A4
G2RL-14
G2RL-2A4
G2RL-24
High-capacity
Flux protection
Fully sealed
G2RL-1A-E
G2RL-1A4-E
G2RL-1A-H
G2RL-1-E
G2RL-14-E
G2RL-1-H
---
---
---
---
---
---
High-sensitivity
Flux protection
Note: When ordering, add the rated coil voltage to the model number.
Example: G2RL-1A 12 VDC
Rated coil voltage
Model Number Legend
G2RL-@@@-@
1
2
3
4
1. Number of Poles
1: 1 pole
4. Classification
None: General purpose
2: 2 poles
2. Contact Form
None: @PDT
E:
H:
High capacity (1 pole)
High sensitivity (1 pole)
A:
@PST-NO
3. Enclosure Ratings
None: Flux protection
4:
Fully sealed
Specifications
■ Coils Ratings for General-purpose and High-capacity Models
Rated voltage
5 VDC
80.0 mA
62.5 Ω
12 VDC
33.3 mA
360 Ω
24 VDC
16.7 mA
1,440 Ω
48 VDC
8.96 mA
5,358 Ω
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
70% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Approx. 400 mW
Power consumption
Approx. 430 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
1
G2RL
G2RL
■ Coils Ratings for High-sensitivity Models
Rated voltage
5 VDC
50.0 mA
100 Ω
12 VDC
20.8 mA
576 Ω
24 VDC
10.42 mA
2,304 Ω
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
75% max. of the rated voltage
10% min. of the rated voltage
180% of rated voltage (at 23°C)
Approx. 250 mW
Power consumption
Note: The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
■ Contact Ratings
Item
Number of poles
Contact material
Load
General-purpose Models
High-capacity Models
High-sensitivity Models
1 pole
2 poles
1 pole
1 pole
Ag Alloy (Cd free)
Resistive load (cosφ=1)
Rated load
12 A at 250 VAC
12 A at 24 VDC (See
note.)
8 A at 250 VAC
16 A at 250 VAC
10 A at 250 VAC
8 A at 30 VDC (See note.) 16 A at 24 VDC (See note.) 10 A at 24 VDC
(See note.)
Rated carry current
12 A (See note.)
8 A (70°C)/5 A (85°C)
16 A (See note.)
10 A (See note.)
(See note.)
Max. switching voltage 440 VAC, 300 VDC
Max. switching current 12 A
8 A
16 A
10 A
Max. switching power
3,000 VA
2,000 VA
4,000 VA
2,500 VA
Note: Contact your OMRON representative for the ratings on fully sealed models.
■ Characteristics
Item
General-purpose
General-purpose Models
2 pole
High-sensitivity Models
(High-capacity) Models
Number of poles
1 pole
1 pole
Contact resistance
Operate (set) time
Release (reset) time
100 mΩ max.
15 ms max.
5 ms max.
Max. operating frequency Mechanical:18,000 operation/hr
Electrical:1,800 operation/hr at rated load
Insulation resistance
Dielectric strength
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 1 min between coil and 5,000 VAC, 1 min between coil and 5,000 VAC, 1 min between coil and
contacts
1,000 VAC, 1 min between con-
tacts of same polarity
contacts
contacts
2,500 VAC, 1 min between contacts 1,000 VAC, 1 min between con-
of different polarity
1,000 VAC, 1 min between contacts
of same polarity
tacts of same polarity
Impulse withstand voltage 10 kV (1.2×50 µs) between coil and contact
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2 (approx. 100 G)
Malfunction: 100 m/s2 (approx. 10 G)
Endurance (Mechanical)
Ambient temperature
20,000,000 operations (at 18,000 operations/hr)
Operating:
Storage:
–40°C to 85°C (with no icing)
–40°C to 85°C (with no icing)
Ambient humidity
Weight
5% to 85%
Approx. 12 g
Note: Values in the above table are the initial values.
■ Approved Standards
UL508 (File No. E41643)/CSA C22.2 (No. 14) (File No. LR31928)
Model
Contact form
Coil ratings
Contact ratings
G2RL-1A
G2RL-1
SPST-NO
SPDT
3 to 48 VDC
12 A at 250 VAC (General use)
12 A at 24 VDC (Resistive)
G2RL-1A-E
G2RL-1-E
G2RL-1A-H
G2RL-1-H
G2RL-2A
G2RL-2
SPST-NO
SPDT
16 A at 250 VAC (General use)
16 A at 24 VDC (Resistive)
SPST-NO
SPDT
5 to 24 VDC
3 to 48 VDC
10 A at 250 VAC (General use)
10 A at 24 VDC (Resistive)
DPST-NO
DPDT
8 A at 277 VAC (General use)
8 A at 30 VDC (Resistive)
2
G2RL
G2RL
VDE (EN61810-1) (License No. 119650)
Model
Contact form
Coil ratings
Contact ratings
G2RL-1(A)
1 pole
5, 12, 18, 22, 24, 48 VDC
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC
DC13: 2.5 A at 24 VDC, 50 ms
G2RL-1(A)-E
1 pole
5, 12, 18, 22, 24, 48 VDC
16 A at 250 VAC (cosφ=1)
16 A at 24 VDC (L/R=0 ms)
AC15: 3 A at 240 VAC (NO)
1.5 A at 240 VAC (NC)
DC13: 2.5 A at 24 VDC (NO), 50 ms
G2RL-1(A)-H
G2RL-2(A)
1 pole
5, 9, 12, 24 VDC
10 A at 250 VAC (cosφ=1)
10 A at 24 VDC (L/R=0 ms)
2 poles
5, 12, 18, 22, 24, 48 VDC
8 A at 250 VAC (cosφ=1)
8 A at 24 VDC (L/R=0 ms)
AC15: 1.5 A at 240 VAC
DC13: 2 A at 30 VDC, 50 ms
Engineering Data
Maximum Switching Capacity
G2RL-1A, G2RL-1
G2RL-1A-E, G2RL-1-E
G2RL-2A, G2RL-2
50
50
50
AC resistive load
AC resistive load
AC resistive load
10
10
5
10
5
DC resistive
load
5
DC resistive
load
DC resistive
load
1
1
1
0.5
0.5
0.5
0.1
0.1
0.1
0
5
10 20 30 50 100
5001,000
0
5
10 20 30 50 100
5001,000
0
5
10 20 30 50 100
5001,000
Switching voltage (V)
Switching voltage (V)
Switching voltage (V)
Ambient Temperature
vs Rated Carry Current
Ambient Temperature
vs Maximum Coil Voltage
250
G2RL-1A-H, G2RL-1-H
G2RL-1A-E, G2RL-1-E
AC resistive load
200
180
G2RL-1A, G2RL-1
150
130
DC resistive
load
G2RL-1A-H, G2RL-1-H
G2RL-2A, G2RL-2
100
50
0
10 20 30 40 50 60 70 80 85 90 100
Ambient temperature (°C)
Switching voltage (V)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power
voltage, not a continuous voltage.
Ambient Temperature vs
Must Operate and
Must Release Voltages
100
Sample: G2RL-14-E 24 VDC
Quantity: 5
Must operate voltage
Must release voltage
90
80
70
60
50
40
30
20
10
max.
min.
max.
min.
0
20
40
60
80
100 120
Ambient temperature (°C)
3
G2RL
G2RL
Shock Malfunction
G2RL-1 (A)-E
G2RL-2 (A)
Y
Y
1,000
1,000
NO contact
NO contact
Sample:
G2RL-14 DC12V
Sample:
G2RL-24 DC12V
Number of Relays: 5pcs
Number of Relays: 5pcs
Conditions: Shock is applied in X, Y, Z
X'
1,000
Z
X'
1,000
Z
Conditions:
Shock is applied in X, Y,
directions three times each
Z
1,000
1,000
directions three times each
with and without energizing the
Relays to check the number of
malfunctions.
with and without energizing the
Relays to check the number of
malfunctions.
150
130
Requirement:
None malfunction 100m/s2
Requirement:
None malfunction 100m/s2
1,000
X
1,000
Z'
1,000
X
1,000
NC contact
NC contact
Z'
Shock direction
Shock direction
X
Y
X'
X
X'
Y
Z
Z
1,000
Unit: m/s2
1,000
Y'
Unit: m/s2
Y'
Z'
Z'
Y'
Y'
Electrical Endurance Data
G2RL-1-E
16 A at 250 VAC (cosφ=1)
30,000 operations min.
30,000 operations min.
200,000 operation min. (normally open side operation)
10,000 operation min. (normally open side operation)
16 A at 24 VDC
8 A at 250 VAC (cosφ=0.4)
8 A at 30 VDC (L/R=7 ms)
G2RL-1
12 A at 250 VAC (cosφ=1)
12 A at 24 VDC
50,000 operations min.
30,000 operations min.
5 A at 250 VAC (cosφ=0.4)
150,000 operation min. (normally open side operation)
20,000 operation min. (normally open side operation)
5 A at 30 VDC (L/R=7 ms)
G2RL-1-H
G2RL-2
10 A at 250 VAC (cosφ=1)
100,000 operations min.
50,000 operations min.
10 A at 24 VDC
8 A at 250 VAC (cosφ=1)
30,000 operations min.
30,000 operations min.
8 A at 30 VDC
Note: The results shown reflect values measured using very severe test conditions i.e., Duty: 1 s ON/1 s OFF.
Electrical endurance will vary depending on the test conditions. Contact your OMRON representative if you require more detailed information for the
electrical endurance under your test conditions.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
G2RL-1A(-H), G2RL-1A4
(Bottom View)
Four, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
3.5
29 max.
(28.8)*
(2.5)
1
3
7.5
15.7 max.
(15.5)*
4
5
(2.3)
20
* Indicates average dimensions.
0.8
0.5
0.5
0.5
3.5
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
G2RL-1(-H), G2RL-14
(Bottom View)
Five, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
3.53.5
29 max.
(28.8)*
2
1
3
(2.5)
7.5
15.7 max.
(15.5)*
5
4
(2.3)
20
* Indicates average dimensions.
0.8
0.5
0.5
0.5
3.5
0.5
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)
5
G2RL-1A-E, G2RL-1A4-E
Six, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
3
4
1
7.5
15.7 max.
(15.5)*
6
5
8
(2.3)
20
* Indicates average dimensions.
0.8
0.5
0.5
0.5
3.5
4
G2RL
G2RL
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)
G2RL-1-E, G2RL-14-E
Eight, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
5
5
29 max.
(28.8)*
(2.5)
1
4
2
3
7.5
15.7 max.
(15.5)*
6
8
7
5
(2.3)
20
0.8
0.5
0.5
0.5
* Indicates average dimensions.
3.5
0.5
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)
5
G2RL-2A, G2RL-2A4
G2RL-2, G2RL-24
Six, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
29 max.
(28.8)*
(2.5)
4
3
1
8
7.5
15.7 max.
(15.5)*
6
5
20
(2.3)
0.8 * Indicates average dimensions.
0.5
0.5
0.5
3.5
Terminal Arrangement/
Internal Connection
(Bottom View)
Mounting Holes
(Bottom View)
Eight, 1.3 0.1 dia.
holes
12.7 max.
(12.5)*
5
5
29 max.
(28.8)*
(2.5)
2
4
1
3
7.5
15.7 max.
(15.5)*
5
8
7
6
(2.3)
20
* Indicates average dimensions.
0.8
0.5
0.5
0.5
3.5
0.5
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. X033-E1-14A
In the interest of product improvement, specifications are subject to change without notice.
相关型号:
G2RL-1ATP-E-DC12
Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 16A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
G2RL-1ATP-E-DC24
Power/Signal Relay, SPST, Momentary, 0.017A (Coil), 24VDC (Coil), 400mW (Coil), 16A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
G2RL-1ATP-E-DC48
Power/Signal Relay, SPST, Momentary, 0.009A (Coil), 48VDC (Coil), 430mW (Coil), 16A (Contact), 24VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
OMRON
G2RL-1DC12
Power/Signal Relay, SPDT, Momentary, 0.033A (Coil), 12VDC (Coil), 400mW (Coil), 12A (Contact), 300VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G2RL-2-24VDC
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON
G2RL-2-48VDC
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.009A (COIL), 48VDC (COIL), 430mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON
G2RL-2-5VDC
POWER/SIGNAL RELAY, DPDT, MOMENTARY, 0.08A (COIL), 5VDC (COIL), 400mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明