G3RV-SR700-AAC/DC24 [OMRON]

Global standard size, low profile slim (6.2 mm width) I/O relays;
G3RV-SR700-AAC/DC24
型号: G3RV-SR700-AAC/DC24
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Global standard size, low profile slim (6.2 mm width) I/O relays

文件: 总31页 (文件大小:2878K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Slim I/O Relays  
G2RV-SR/G3RV-SR  
Global standard size, low profile  
slim (6.2 mm width) I/O relays  
G2RV-SR:  
G3RV-SR:  
• 25% lower profile than conventional products, contributing  
to a smaller control panel.  
• Push-In Plus terminal blocks reduce wiring work by 60%*  
compared to conventional screw terminals.  
• ‘Hand-free’ structure that holds an inserted flat-blade  
screwdriver to achieve easier wiring work for stranded  
wires.  
Electromechanical relays (G2RV-SR) and solid state  
relays (G3RV-SR) are available.  
• Screw terminal terminal block models are available.  
Plug-in terminal has strong mechanical pins that do not  
bend.  
* According to OMRON actual measurement data from November 2015.  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
Refer to Safety Precautions on page 20.  
Slim I/O Relay Types  
G2RV-SR series mounted relay: electromagnetic relay ......from page 2  
G3RV-SR series mounted relay: solid state relay ................from page 10  
Common matter  
Common precautions................................................................from page 20  
Common accessories (order separately).................................page 24  
1
Slim Electromechanical I/O Relay  
G2RV-SR  
Global standard size, low profile,  
slim (6.2 mm width) I/O relay  
• 25% lower profile than conventional products, contributing  
to a smaller control panel.  
Opening and closing ability with one pole 6 A slim shape.  
• Micro load products for one pole 50 mA using gold-plated  
contacts for small load switching also available.  
• Since G2RV has a transparent case, confirming the state  
of the contact with the naked eye is possible.  
Screw terminal terminal block models are available.  
Plug-in type terminal has strong mechanical pins that do  
not bend.  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
Refer to Safety Precautions on page 20.  
Features  
With latching lever  
Push-In Plus Terminal Block  
Standard model/Micro load  
(Test switch)  
Terminal x 5  
• Push-in  
• Screw  
Short bar insertion holes  
Protective cover  
(Released state)  
Operation  
display LED  
(Socket section)  
Release hole  
Release lever  
Protective cover  
(Locked condition)  
Latching lever  
(Test switch)  
Terminal (insertion) hole  
Latching lever  
(Test switch)  
• Circuit check operation  
Confirmation, reducing the inspection effort  
Mechanical  
indicator  
• Operation  
verification  
which is linked  
to the contact  
PAT  
"Foreign matter intrusion prevention structure"  
"Malfunction prevention stopper"  
Transparent case  
Relay contact  
Easy confirmation  
of the situation  
Release lever  
Relay easily  
fixed/removed  
90 mm  
Plug-in terminal  
Terminal has strong  
mechanical pins that  
do not bend.  
80 mm  
2
G2RV-SR  
Model Number Structure  
Model Number Legend  
G2RV-SR @@ @ - @ @  
(1)  
(2) (3) (4) (5) (6)  
(1) Basic model name  
G2RV: Slim I/O Relay  
(3) Terminal (wire connection)  
50: Push-In Plus Terminal  
70: Screw terminal  
(5) Contact structure  
Blank: Standard  
AP: Microloads  
(2) Sub type  
(6) Rated input voltage  
12, 24 VDC  
24, 48 VAC/VC  
SR: Slim relay + integrated low profile socket  
(4) Latching lever (test switch)  
0: Without latching lever  
1: With latching lever  
100, 110, 200, 230 VAC  
Ordering Information  
Terminal  
(Wire connection)  
Latching lever  
(Test switch)  
Classification  
Rated input voltage (V)  
Model  
12  
G2RV-SR500 DC12  
DC  
24  
G2RV-SR500 DC24  
24  
G2RV-SR500 AC/DC24  
G2RV-SR500 AC/DC48  
G2RV-SR500 AC100  
AC/DC  
48  
No  
100  
110  
200  
230  
24  
Standard  
G2RV-SR500 AC110  
AC  
G2RV-SR500 AC200  
G2RV-SR500 AC230  
DC  
G2RV-SR501 DC24  
Push-In Plus  
Terminal  
Yes  
AC/DC  
24  
G2RV-SR501 AC/DC24  
G2RV-SR500-AP DC12  
G2RV-SR500-AP DC24  
G2RV-SR500-AP AC/DC24  
G2RV-SR500-AP AC/DC48  
G2RV-SR500-AP AC100  
G2RV-SR500-AP AC110  
G2RV-SR500-AP AC200  
G2RV-SR500-AP AC230  
G2RV-SR700 DC12  
12  
DC  
24  
24  
AC/DC  
48  
Microloads  
No  
100  
110  
200  
230  
12  
AC  
DC  
24  
G2RV-SR700 DC24  
24  
G2RV-SR700 AC/DC24  
G2RV-SR700 AC/DC48  
G2RV-SR700 AC100  
AC/DC  
48  
No  
100  
110  
200  
230  
24  
Standard  
G2RV-SR700 AC110  
AC  
G2RV-SR700 AC200  
G2RV-SR700 AC230  
DC  
G2RV-SR701 DC24  
Screw terminal  
Yes  
AC/DC  
24  
G2RV-SR701 AC/DC24  
G2RV-SR700-AP DC12  
G2RV-SR700-AP DC24  
G2RV-SR700-AP AC/DC24  
G2RV-SR700-AP AC/DC48  
G2RV-SR700-AP AC100  
G2RV-SR700-AP AC110  
G2RV-SR700-AP AC200  
G2RV-SR700-AP AC230  
12  
DC  
24  
24  
AC/DC  
48  
Microloads  
No  
100  
110  
200  
230  
AC  
Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules.  
3
G2RV-SR  
Relay for Maintenance  
Model Number Legend  
G2RV-1-SI-G  
G2RV-1-S-G(-AP)  
G2RV-1 - S @ - @ - G @  
(1) (2) (3) (4) (5) (6)  
(1) No. of poles  
1: 1 pole  
(4) Contact material  
Blank: Silver alloy  
AP: Silver alloy + gold plate  
(2) Terminal  
(5) Types of relay for exchange  
G: G2RV-SR series equipped  
Relay  
S: plug-in  
(3) Latching lever (Test switch)  
Blank: Without latching lever  
I: With latching lever  
(6) Rated coil voltage  
Number: 11, 21, 48 VDC  
List of Models  
Latching  
Lever  
(Test switch)  
Rated coil  
voltage (V)  
Type  
Model  
Applicable model  
11  
G2RV-1-S-G DC11  
G2RV-1-S-G DC21  
G2RV-SR700/500 DC12V  
G2RV-SR700/500 DC24V  
G2RV-SR700/500 AC/DC24V  
G2RV-SR700/500 AC/DC48V  
G2RV-SR700/500 AC100V  
G2RV-SR700/500 AC110V  
G2RV-SR700/500 AC200V  
G2RV-SR700/500 AC230V  
G2RV-SR701/501 DC24V  
G2RV-SR701/501 AC/DC24V  
G2RV-SR700/500-AP DC12V  
G2RV-SR700/500-AP DC24V  
21  
48  
No  
DC  
DC  
DC  
Standard  
G2RV-1-S-G DC48  
Yes  
21  
11  
21  
G2RV-1-SI-G DC21  
G2RV-1-S-AP-G DC11  
G2RV-1-S-AP-G DC21  
G2RV-SR700/500-AP AC/DC24V  
G2RV-SR700/500-AP AC/DC48V  
G2RV-SR700/500-AP AC100V  
G2RV-SR700/500-AP AC110V  
G2RV-SR700/500-AP AC200V  
G2RV-SR700/500-AP AC230V  
Microload No  
48  
G2RV-1-S-AP-G DC48  
4
G2RV-SR  
Specifications  
Ratings  
Coil ratings  
Operation  
voltage  
Maximum  
allowable voltage  
Release  
voltage  
Rated current  
Power consumption  
Rated input  
voltage  
AC  
Percentage of the  
rated voltage  
DC  
Percentage of the rated voltage  
AC (VA)  
DC (mW)  
50 Hz  
60 Hz  
12 VDC  
27.2 mA  
Approx. 300 mW  
Approx. 300 mW  
24 VDC  
13.3 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
21.1 mA 22.5 mA  
13.0 mA  
Approx. 0.5 VA Approx. 300 mW  
Approx. 0.4 VA Approx. 250 mW  
8.5 mA  
7.1 mA  
7.1 mA  
7.2 mA  
7.3 mA  
9.0 mA  
7.5 mA  
7.5 mA  
7.9 mA  
7.9 mA  
5.2 mA  
80% max.*  
10% min.  
110%  
Approx. 0.8 VA  
Approx. 0.8 VA  
Approx. 1.7 VA  
Approx. 1.7 VA  
Note: The operating characteristics are measured at ambient temperature of 23°C.  
* Operating voltage will be 85% max. for upside down mounting.  
Contact ratings  
Item  
Standard (G2RV-SR700, 500, 701, 501)  
For microloads (G2RV-SR700-AP, 500-AP) *2  
Contact configuration  
SPDT  
Resistive load  
(cosφ=1)  
Inductive load  
(cosφ=0.4, L/R=7ms)  
Resistive load  
(cosφ=1)  
Load  
6 A at 250 VAC  
6 A at 30 VDC  
2.5 A at 250 VAC  
2 A at 30 VDC  
50 mA at 30 VAC  
50 mA at 36 VDC  
Rated load  
Rated carry current  
6 A  
50 mA  
Maximum switching voltage  
Maximum switching current  
440 VAC, 125 VDC  
6 A  
30 VAC, 36 VDC  
50 mA  
1,500 VA  
180 W  
500 VA  
60 W  
Maximum switching power  
Failure rate P value  
(reference value) *1  
10 mA at 5 VDC  
1 mA at 100 mVDC  
*1. P level: λ60=0.1×10-6/times  
This value is the value in switching frequency 120 operations/min.  
*2. If the gold plating layer is destroyed, the number will be the same as the standard type.  
Characteristics  
Item  
Contact resistance *  
Operate (Set) time *  
Standard (G2RV-SR700, 500, 701, 501)  
100 mΩ max.  
For microloads (G2RV-SR700-AP, 500-AP)  
20 ms max.  
AC, AC/DC: 40 ms max.  
DC: 20 ms max.  
Release time *  
Mechanical: 18,000 operations/h  
Electrical: 1,800 operations/h (rated load)  
Maximum operating frequency  
Insulation resistance  
1,000 MΩ min. (at 500 VDC)  
Between coil and contacts: 4,000VAC 50/60 Hz 1 min  
Contact between the same polarity: 1,000 VAC 50/60 Hz 1 min  
Dielectric strength  
Destruction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)  
Malfunction: 10 to 55 to 10 Hz, single amplitude 0.50 mm (double amplitude 1.0 mm)  
Vibration resistance  
Shock resistance  
Destruction: 1,000 m/s2  
Malfunction: Energized 200m/s2, Non-energized 100m/s2  
Mechanical 5,000,000 operations min.  
Endurance *  
NO contact: 70,000 operations min.  
5,000,000 operations min.  
Electrical  
NC contact: 50,000 operations min.  
Ambient operating temperature Operating: –40 to +55°C (with no icing or condensation)  
Ambient operating humidity  
Weight  
Operating: 5 to 85% RH  
Approx. 30 g  
Contact material  
Ag alloy  
Ag alloy + Au plating  
Note: Above values are initial values.  
* Value is at ambient temperature of 23°C.  
5
G2RV-SR  
Approved standards  
UL508 (file No.E41643)  
Model  
No. of poles  
Operation coil ratings  
Contact ratings  
Operations  
6 A at 250 VAC (Resistive load)  
6 A at 30 VDC (Resistive load)  
2 A at 400 VAC (Resistive  
load)*  
12 to 48 VDC  
24 to 230 VAC  
G2RV-SR series  
SPDT  
6,000  
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).  
12 mm 12 mm 12 mm  
VDE (EN 61810-1)  
Model  
No. of poles  
Operation coil ratings  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
Contact ratings  
Operations  
6 A at 250 VAC (Resistive load)  
6 A at 30 VDC (Resistive load)  
2 A at 400 VAC (Resistive  
load)*  
50,000  
50,000  
6,000  
G2RV-SR series  
SPDT  
* If the load voltage exceeds 250 VAC, please attach with a spacing of 12 mm min., or use a separate plate (XW5Z-EP12).  
12 mm 12 mm 12 mm  
Engineering Data  
Endurance curve (N.O. side)  
Switching capacity of DC resistive load  
10.0  
1000  
30 VDC resistive load  
250 VAC resistive load  
1.0  
100  
30 VDC  
resistive load  
250 VAC resistive load  
10  
0
0.1  
2
4
6
20  
60  
100  
140  
180  
220  
Opening and closing current (A)  
DC switching voltage (V)  
6
G2RV-SR  
Dimensions  
(unit: mm)  
Slim I/O Relay + socket  
Push-In Plus Terminal Block  
Models without latching lever (without test switch)  
G2RV-SR500  
G2RV-SR500-AP  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
78 max.  
Input circuit  
A1  
A2  
G2RV  
3.4  
74.5  
65.89  
Other voltage  
35.25  
18.78  
Input circuit  
(5.05)  
A1  
A2  
G2RV  
12  
14  
11  
78.77  
35.3  
90 max.  
24 VDC  
Input circuit  
12  
14  
A1  
A2  
G2RV  
11  
*
: Diode bridge  
(5.05)  
: Light emitting diode  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
12  
14  
11  
Models with latching lever (with test switch)  
G2RV-SR501  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
81 max.  
Input circuit  
A1  
A2  
G2RV  
3.4  
77.5  
65.89  
Other voltage  
Input circuit  
A1  
35.25  
18.78  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
24 VDC  
35.3  
90 max.  
Input circuit  
A1  
A2  
12  
14  
G2RV  
11  
*
: Diode bridge  
(5.05)  
: Light emitting diode  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
12  
14  
11  
7
G2RV-SR  
Screw terminal  
Models without latching lever (without test switch)  
G2RV-SR700  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
G2RV-SR700-AP  
12 VDC  
Input circuit  
A1  
78 max.  
A2  
G2RV  
3.4  
74.5  
65.89  
Other voltage  
35.18  
18.71  
Input circuit  
A1  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
35.3  
90 max.  
24 VDC  
Input circuit  
12  
14  
A1  
A2  
G2RV  
11  
*
: Diode bridge  
(5.05)  
18.71  
35.18  
51.65  
56.2  
: Light emitting diode  
6.2 max.  
12  
14  
11  
Models with latching lever (with test switch)  
G2RV-SR701  
Terminal Arrangement/Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
Input circuit  
A1  
81 max.  
77.5  
A2  
G2RV  
3.4  
Other voltage  
Input circuit  
A1  
65.89  
35.18  
18.71  
(5.05)  
A2  
G2RV  
12  
14  
11  
78.77  
24 VDC  
35.3  
90 max.  
Input circuit  
12  
14  
A1  
A2  
G2RV  
11  
*
: Diode bridge  
(5.05)  
18.71  
35.18  
51.65  
56.2  
: Light emitting diode  
6.2 max.  
12  
14  
11  
8
G2RV-SR  
Relay for maintenance  
Models without latching lever  
G2RV-1-S-G  
G2RV-1-S-AP-G  
5.2 max.  
30.5 max.  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
33 max.  
(Input circuit)  
16.2  
12  
A1 A2  
14 11  
1.8  
0.5  
2.4  
3.5  
5.04  
5.04  
22  
3
Models with latching lever (test switch)  
G2RV-1-SI-G  
5.2 max.  
30.5 max.  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
(Input circuit)  
36 max.  
12  
A1 A2  
14 11  
16.2  
0.5  
1.8  
2.4  
3.5  
5.04  
5.04  
22  
3
9
GSlim3I/ORSoVlid S-tSateRRelay  
Global standard size, low profile, slim  
(6.2 mm width) I/O solid state relay.  
• 25% lower profile than conventional products, contributing to a  
smaller control panel.  
• Optimal slim, high frequency, high-speed opening and closing  
SSR (solid state relay).  
Slim shape with a switching capacity up to 3 A (DC), and  
2 A (AC).  
• Because MOSFET is used for the outlet element for the DC  
load, opening and closing load of 100 µA to 3 A is possible.  
• Check operating status at a glance with the operating display  
LED.  
• Mounted I/O SSR (solid-state relay) uses plug-in terminals with  
strong mechanical pins that do not bend.  
For the recent information on models that have been certified  
for safety standards, refer to your OMRON website.  
Refer to Safety Precautions on page 20.  
Features  
Push-In Plus Terminal Block  
Terminal x 5  
• Push-in  
• Screw  
Short bar insertion holes  
Release hole  
Operation display LED  
(Socket section)  
Release lever  
Operation  
display LED  
(SSR section)  
Terminal (insertion) hole  
Release lever  
Relay easily  
fixed/removed  
90 mm  
Plug-in terminal  
Terminal has strong  
mechanical pins that  
do not bend.  
80 mm  
10  
G3RV-SR  
Model Number Structure  
Model Number Legend  
G3RV-SR @ @ @ - @ @  
(1)  
(2)  
(3)  
(4) (5)  
(1) Basic model name  
G3RV: Slim I/O Solid State Relay  
(4) Output voltage specification  
: AC output (triac) zero cross function available  
AL : AC output (triac) zero cross function not available  
: DC output (MOS FET)  
A
(2) Sub type  
D
SR: Slim solid relay + integrated low profile socket  
(5) Rated voltage input  
12, 24 VDC  
24, 48 VAC/VDC  
(3) Terminal (wire connection)  
500: Push-In Plus Terminal  
700: Screw terminal  
100, 110, 200, 230 VAC  
11  
G3RV-SR  
Ordering Information  
Terminal  
(wire connection)  
Applicable  
output load  
Zero cross  
function  
Rated input voltage  
(V)  
Model  
12  
G3RV-SR500-D DC12  
G3RV-SR500-D DC24  
G3RV-SR500-D AC/DC24  
G3RV-SR500-D AC/DC48  
G3RV-SR500-D AC100  
G3RV-SR500-D AC110  
G3RV-SR500-D AC200  
G3RV-SR500-D AC230  
G3RV-SR500-A DC12  
G3RV-SR500-A DC24  
G3RV-SR500-A AC/DC24  
G3RV-SR500-A AC/DC48  
G3RV-SR500-A AC100  
G3RV-SR500-A AC110  
G3RV-SR500-A AC200  
G3RV-SR500-A AC230  
G3RV-SR500-AL DC12  
G3RV-SR500-AL DC24  
G3RV-SR500-AL AC/DC24  
G3RV-SR500-AL AC/DC48  
G3RV-SR500-AL AC100  
G3RV-SR500-AL AC110  
G3RV-SR500-AL AC200  
G3RV-SR500-AL AC230  
G3RV-SR700-D DC12  
G3RV-SR700-D DC24  
G3RV-SR700-D AC/DC24  
G3RV-SR700-D AC/DC48  
G3RV-SR700-D AC100  
G3RV-SR700-D AC110  
G3RV-SR700-D AC200  
G3RV-SR700-D AC230  
G3RV-SR700-A DC12  
G3RV-SR700-A DC24  
G3RV-SR700-A AC/DC24  
G3RV-SR700-A AC/DC48  
G3RV-SR700-A AC100  
G3RV-SR700-A AC110  
G3RV-SR700-A AC200  
G3RV-SR700-A AC230  
G3RV-SR700-AL DC12  
G3RV-SR700-AL DC24  
G3RV-SR700-AL AC/DC24  
G3RV-SR700-AL AC/DC48  
G3RV-SR700-AL AC100  
G3RV-SR700-AL AC110  
G3RV-SR700-AL AC200  
G3RV-SR700-AL AC230  
DC  
24  
24  
AC/DC  
48  
DC load  
AC load  
DC load  
AC load  
Yes  
No  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
Push-In Plus Terminal  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
Screw terminal  
Yes  
100  
110  
AC  
200  
230  
12  
DC  
24  
24  
AC/DC  
48  
No  
100  
110  
AC  
200  
230  
Note: Solid wire cannot be used for Push-In Plus terminal type. Make sure to use stranded wire or stranded wire with ferrules.  
12  
G3RV-SR  
Solid state relay for maintenance  
Model Number Legend  
G3RV-@ @ S @ @  
(1) (2) (3) (4) (5)  
(1) Output voltage  
specification  
D: DC output  
(3) Terminal  
S: Plug-in type  
(4) Zero cross functions  
2: AC output  
Blank: Zero cross function available  
L: Zero cross function not available  
(2) Rated current  
02: AC output 2 A  
03: DC output 3 A  
(5) Rated input voltage  
Number: 12, 24, 48 VDC  
List of Models  
Rated  
output  
Load *  
Rated input  
voltage  
(socket)  
Insulation Operation Output Zero cross  
Model  
Applicable model  
method  
Display  
(SSR) Function  
12 VDC  
G3RV-202S DC12  
G3RV-202S DC24  
G3RV-SR700/500-A DC12V  
G3RV-SR700/500-A DC24V  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
12 VDC  
G3RV-SR700/500-A AC/DC24V  
G3RV-SR700/500-A AC/DC48V  
G3RV-SR700/500-A AC100V  
G3RV-SR700/500-A AC110V  
G3RV-SR700/500-A AC200V  
G3RV-SR700/500-A AC230V  
G3RV-SR700/500-AL DC12V  
G3RV-SR700/500-AL DC24V  
G3RV-SR700/500-AL AC/DC24V  
G3RV-SR700/500-AL AC/DC48V  
G3RV-SR700/500-AL AC100V  
G3RV-SR700/500-AL AC110V  
G3RV-SR700/500-AL AC200V  
G3RV-SR700/500-AL AC230V  
G3RV-SR700/500-D DC12V  
G3RV-SR700/500-D DC24V  
G3RV-SR700/500-D AC/DC24V  
G3RV-SR700/500-D AC/DC48V  
G3RV-SR700/500-D AC100V  
G3RV-SR700/500-D AC110V  
G3RV-SR700/500-D AC200V  
G3RV-SR700/500-D AC230V  
Yes  
G3RV-202S DC48  
2 A  
(at 100 to  
240  
Photo-  
triac  
AC  
G3RV-202SL DC12  
G3RV-202SL DC24  
VAC)  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
12 VDC  
Yes  
(green)  
No  
G3RV-202SL DC48  
G3RV-D03SL DC12  
G3RV-D03SL DC24  
24 VDC  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
110 VAC  
200 VAC  
230 VAC  
Photo-  
voltage  
coupler  
3 A  
(at 5 to  
24 VDC)  
DC  
G3RV-D03SL DC48  
* Different depending on the ambient temperature.  
For more details, refer to Load current vs. ambient rated temperature on page 16.  
13  
G3RV-SR  
Specifications  
Rating (ambient temperature 25°C)  
Input  
G3RV-SR700/500-A series  
Rated current  
Input voltage  
Rated input  
voltage  
Release  
voltage  
Operation  
voltage  
AC  
Percentage of the  
rated voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
15 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
12 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
20 mA  
10 mA  
7.5 mA  
7.5 mA  
7.3 mA  
7.3 mA  
21 mA  
11 mA  
7.5 mA  
7.7 mA  
8.6 mA  
8.6 mA  
11 mA  
6 mA  
1 V min.  
10%  
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
G3RV-SR700/500-AL series  
Rated current  
AC  
Input voltage  
Release  
voltage  
Operation  
voltage  
Rated input  
voltage  
Percentage of the  
rated voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
15 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
12 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
20 mA  
10 mA  
7.5 mA  
7.5 mA  
7.3 mA  
7.3 mA  
21 mA  
11 mA  
7.7 mA  
7.7 mA  
8.6 mA  
8.6 mA  
11 mA  
6 mA  
1 V min.  
10%  
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
G3RV-SR700/500-D series  
Rated current  
AC  
Input voltage  
Rated input  
voltage  
Operation  
voltage  
Release  
voltage  
Percentage of the  
rated voltage  
DC  
50 Hz  
60 Hz  
12 VDC  
8 mA  
10.8 V max.  
21.6 V max.  
21.6 V max.  
43.2 V max.  
90 V max.  
24 VDC  
4.5 mA  
24 VAC/VDC  
48 VAC/VDC  
100 VAC  
10.7 mA 11.1 mA 4.3 mA  
9.6 mA  
6.8 mA  
6.8 mA  
6.8 mA  
6.8 mA  
10.2 mA 6 mA  
10%  
1 V min.  
7.2 mA  
7.2 mA  
8.1 mA  
8.1 mA  
110 VAC  
99 V max.  
200 VAC  
180 V max.  
207 V max.  
230 VAC  
Output  
Item  
G3RV-SR700/500-A(L)  
G3RV-SR700/500-D  
Rated load voltage  
Load voltage range  
Load current  
100 to 240 VAC (50/60 Hz)  
75 to 264 VAC (50/60 Hz)  
5 to 24 VDC  
3 to 26.4 VDC  
0.1 to 2 A (Ambient temperature=25°C) 100 µA to 3 A (Ambient temperature=25°C)  
Inrush current resistance  
Permissible l2t; Joule integral value  
(reference value)  
30 A (60 Hz, 1 cycle)  
15A2s  
30 A (60 Hz, 1 cycle)  
9 A2 s  
400 W  
72 W  
Applied load capacity  
(Output voltage: 200 VAC)  
(Output voltage: 24 VDC)  
14  
G3RV-SR  
Characteristics  
Item  
G3RV-SR700/500-A  
G3RV-SR700/500-AL  
3 ms max.  
60 ms max.  
G3RV-SR700/500-D  
6 ms max.  
1/2 cycle of load power supply  
+1 ms max.  
Operate time  
Release time  
60 ms max.  
60 ms max.  
Output ON voltage drop  
Output ON resistance  
1.6 V (RMS) max.  
0.3 Ω max. (at 24 VDC)  
Leakage current  
5 mA max. (at 200 VAC, 50/60 Hz)  
10 µA max. (at 24 VDC)  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
100 MΩ min. (at 500 VDC)  
Between input and output 2,500 VAC 50/60 Hz 1 min  
Malfunction: 10 to 55 to 10 Hz double amplitude 0.70 mm  
300m/s2  
Storage: –30 to +100°C (with no icing or no condensation)  
Operating: –30 to +55°C (with no icing or no condensation)  
Ambient operating temperature  
Ambient operating humidity  
Weight  
45 to 85% RH  
Approx. 38 g  
2
Pollution degree  
The degree of protection by  
IEC60529  
IP20  
Rated impulse dielectric  
strength  
4.0 kV/III  
Load category  
LC-A  
DC-12  
1.5Ie 1.1Ue  
5s ON, 10s OFF, 10 cycles  
Overload current profile  
Rated insulation voltage  
240 V  
Approved standards  
UL 508 (file No.E64562)  
Model  
Input ratings  
12, 24 VDC  
24, 48 VAC/VDC  
Contact ratings  
24 VDC 3 A (resistive load) at 25°C  
G3RV-SR700/500-D series  
G3RV-SR700/500-A(L) series  
100, 110, 200, 230 VAC  
12, 24 VDC  
24, 48 VAC/DC  
240 VAC 2 A (resistive load) at 25°C  
100, 110, 200, 230 VAC  
TÜV 62314  
Model  
Input ratings  
Contact ratings  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
G3RV-SR700/500-D series  
G3RV-SR700/500-A(L) series  
24 VDC 3 A (resistive load)  
12, 24 VDC  
24, 48 VAC/VDC  
100, 110, 200, 230 VAC  
240 VAC 2 A (resistive load)  
15  
G3RV-SR  
Engineering Data  
Load current vs. ambient rated temperature  
G3RV-SR700/500-A(L) series  
Product mounting spacing 10 mm (Separate Mounting)  
Close mounting (up to 5 units *)  
5
5
4
3
2
4
3
2
1
1
0
0.2  
0
−30 −20  
−30 −20  
0
20 25 40 55 60  
80  
100  
0
20 25 40 55 60  
80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
G3RV-SR700/500-D series  
Product mounting spacing 10 mm (Separate Mounting)  
Close mounting (up to 5 units *)  
5
5
4
3
2
4
3
2
1
1
0
0.5  
0
−30 −20  
0
20 25 40 55 60  
80  
100  
−30 −20  
0
20 25 40 55 60  
80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
* When five or more are installed, install with 10 mm space between  
each.  
For details, please refer to Mounting on page 23.  
Inrush Current Resistance: Non-repetitive  
Keep the inrush current to below the inrush current resistance value (i.e., below the broken line) if it occurs repetitively.  
G3RV-SR700/500-A(L) series  
G3RV-SR700/500-D series  
40  
40  
35  
30  
35  
30  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
0
0
10  
30 50 100  
300 500 1,000 3,000 5,000  
Energized time (ms)  
10  
30 50 100  
300 500 1,000 3,000 5,000  
Energized time (ms)  
16  
G3RV-SR  
Dimensions  
(unit: mm)  
Solid state relay + socket  
Push-In Plus Terminal Block  
G3RV-SR500  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
Input circuit  
A1  
78 max.  
G3RV  
A2  
A2–  
INPUT  
3.4  
74.5  
A1+  
65.89  
13 (+)  
35.25  
18.78  
OUTPUT  
(5.05)  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
13  
78.77  
35.3  
90 max.  
24 VDC  
Input circuit  
A1  
A2  
G3RV  
A2–  
INPUT  
A1+  
(5.05)  
18.78  
35.25  
51.72  
59.71  
6.2 max.  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
13  
Other voltage  
Input circuit  
A1  
A2  
G3RV  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
13  
*
: Diode bridge  
: Light emitting diode  
17  
G3RV-SR  
Screw terminal  
G3RV-SR700  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
12 VDC  
78 max.  
Input circuit  
A1  
3.4  
74.5  
G3RV  
A2  
65.89  
35.18  
18.71  
A2–  
INPUT  
(5.05)  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
78.77  
35.3  
90 max.  
13  
24 VDC  
Input circuit  
A1  
A2  
(5.05)  
18.71  
35.18  
51.65  
56.2  
G3RV  
6.2 max.  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
13  
Other voltage  
Input circuit  
A1  
A2  
G3RV  
A2–  
INPUT  
A1+  
13 (+)  
OUTPUT  
14 (–)  
12  
14  
The information in  
parentheses in for  
a DC output.  
13  
*
: Diode bridge  
: Light emitting diode  
18  
G3RV-SR  
Solid state relay for maintenance  
Terminal Arrangement/  
Internal Connection Diagram  
(TOP VIEW)  
G3RV-D03SL  
G3RV-202S(L)  
G3RV-D03SL (input circuit)  
Input  
30.5 max.  
Load  
33 max.  
15.8  
14 13  
G3RV-202S(L) (input circuit)  
Input  
A1 A2  
1.8  
3.5  
2.4  
22  
3
5.04  
5.2 max.  
Load  
14 13  
A1 A2  
19  
G2RV-SR/G3RV-SR  
Safety Precautions  
Be sure to read the Safety Precautions for All Relays in the website at the following URL:  
www.omron247.com.  
Format of Warning Indications  
Minor burns may occasionally occur.  
Indicates a potentially hazardous situation  
which, if not avoided, will result in minor or  
moderate injury, or may result in serious  
injury or death. Additionally, there may be  
significant property damage.  
Do not touch the G3RV or the heat sink while the  
power is being supplied or immediately after the  
power supply has been turned OFF.  
WARNING  
The G3RV becomes extremely hot.  
Provide a space of at least 3 mm between the G2RV-  
SR and ground. Not doing so may result in a ground  
fault.  
Indicates a potentially hazardous situation  
which, if not avoided, may result in minor or  
moderate injury or in property damage.  
CAUTION  
Indicates supplementary comments on  
what to do or avoid doing, to use the  
product safety.  
Precautions  
for Safe Use  
Precautions for Safe Use  
Includes operating precautions to ensure  
that the product will operate properly and  
that performance and functions will not be  
adversely affected.  
Precautions  
for Correct  
Use  
Transport  
• Do not use the product if it has been dropped on the ground.  
Dropping the product may adversely affect performance.  
• Do not drop the product or subject it to abnormal vibration or shock  
during transportation or mounting. Doing so may result in  
deterioration of performance, malfunction, or failure.  
• Do not transport the product without it being packaged. Doing so  
may result in damage, malfunction, or failure.  
• Do not transport the G3RV under the following conditions. Doing  
so may result in damage, malfunction, or deterioration of  
performance characteristics.  
Meaning of Graphic Symbols for Ensuring Product Safety  
Indicates the possibility of electric shock under  
specific conditions.  
Used for general CAUTION, WARNING, or  
DANGER precautions for which there is no  
specified symbol. (This symbol is also used as  
the alerting symbol, but shall not be used in this  
meaning on the product.)  
• High temperature, high humidity conditions  
• Conditions such as temperature change that causes rapid  
condensation  
Indicates the possibility of explosion or rupture  
under specific conditions.  
• Condition where it is not packaged  
Indicates the possibility of injuries by high  
temperature under specific conditions.  
Operating and Storage Environments  
• Do not use or store the product in the following locations. Doing so  
may result in damage, malfunction, or deterioration of performance  
characteristics.  
WARNING  
Ensure that the socket is not charged during wiring and  
maintenance. Not doing so may result in electric shock.  
• Do not store in locations subject to ambient storage  
temperatures outside the range –40 to 70°C (for G2RV) and  
outside the range –30 to 100°C (for G3RV).  
• Locations subject to relative humidity outside the range 5% to  
85% (for G2RV) and outside the range 45% to 85% (for G3RV).  
• Locations subject to high temperature or high humidity.  
• Conditions such as temperature change that causes rapid  
condensation  
Do not touch the terminal section of the G2RV-SR or  
the surrounding area while the power is being  
supplied. Doing so may result in electric shock.  
CAUTION  
• Locations where corrosive gases or flammable gases are present  
• Location where rainwater or water droplets gets splashed  
• Location with splashes of water, oil, and chemicals, etc.  
• Locations with much dust, salt, and iron powder  
• Location with blockers  
Minor electrical shock may occasionally occur.  
Do not touch the G3RV terminal section (i.e., current  
carrying parts) while the power is being supplied.  
• Where static electricity or noise occurs  
The G3RV may rupture if short-circuit current flows.  
As protection against accidents due to short-circuiting,  
be sure to install protective devices, such as fuses and  
no-fuse breakers, on the power supply side.  
• Where strong electromagnetic field is generated  
• Where there is a risk of exposure to radioactivity  
• Do not use or store Sockets in environments that contain silicone  
gas, sulfidizing gas (e.g., SO2 or H2S), or organic gas, or near  
materials that contain silicone. Doing so may cause the contacts to  
be unstable or to fail.  
Minor electrical shock may occasionally occur.  
Do not touch the main circuit terminals on the G3RV  
immediately after the power supply has been turned  
OFF.  
Shock may result due to the electrical charge stored  
in the built-in snubber circuit.  
Handling <G3RV>  
• Keep the G3RV well ventilated.  
There is a risk of short-circuiting or burning due to G3RV  
overheating.  
Note: G3RV-202S(L), G3RV-SR500/700-A(L) series  
models only  
20  
G2RV-SR/G3RV-SR  
Mounting  
Precautions for Correct Use  
• Before you start wiring, please make sure that the socket is  
securely attached to the mounting rail. If the socket is unstable, it  
may come loose with a risk of injury towards the workers.  
• Please insert the flat-blade screwdriver to the bottom of the hole. If  
you do not insert the flat-blade screwdriver correctly, the cable will  
not be connected correctly.  
• Do not use or store the product in the following locations. Doing so  
may result in damage, malfunction, or deterioration of performance  
characteristics.  
• Where vibration or shock is directly transmitted to the body  
• Do not use the product where the socket could touch a solvent  
or alkaline agent.  
• When lubricant such as oil is attached to the tip of the driver, the  
driver will fall off, with a risk of injury towards the workers.  
• Do not insert short bar in the hole for wire or screw driver, it may  
cause the result of failure of pull out.  
Usage  
If insert short bar in the hole for wire or screw driver and try to pull  
out, it may cause damage for short bar or socket.  
• Please select the load within the rated range. Doing so may result  
in damage, malfunction, or failure.  
• Please use the power of the rated frequency. It may cause  
malfunction, failure, or risk of burnout.  
Push-In Plus Terminal Block  
1. Connecting Wires to the Push-In Plus Terminal Block  
Part Names of the Terminal Block  
<G3RV>  
• Install G3RV according to instructions Mounting on page 23. If you  
install in the wrong direction, abnormal heat is generated, and may  
lead to short-circuiting or burning the output element.  
• G3RV is an SSR that generates heat. Please observe the ambient  
temperature setting range of G3RV. If installing in an enclosed  
space, set a fan, and ventilate.  
Release hole  
Terminal (Insertion) hole  
• When mounting G3RV to DIN rail, firmly fit it into the groove. If it is  
not properly installed, there is a risk of it falling.  
Connecting Wires with Ferrules  
Insert the ferrule straight into the terminal block until the end strikes  
the terminal block.  
Wiring  
For the current to be applied, make sure a wire size with margin is used.  
Otherwise, excessive heat generated by the wires may cause burning  
.
Release hole  
• Do not attempt to use the wire if the coat is torn. Not doing so may  
result in electric shock.  
Terminal  
(Insertion) hole  
• Always turn OFF the power supply before performing wiring. Not  
doing so may cause electrical shock.  
Ferrules  
<G3RV>  
Connecting Stranded Wires  
• The wires of the socket for G3RV socket should not be passed  
Use the following procedure to connect the wires to the terminal block.  
(1) Hold a flat-blade screwdriver at an angle and insert it into the  
release hole.  
through the same duct as that being connected to the high-voltage  
power supply. Otherwise, inductive noise may damage the G3RV  
or cause it to malfunction.  
The angle should be between 10°and15°. If the flat-blade  
screwdriver is inserted correctly, you will feel the spring in the  
release hole respond.  
Push-In Plus Terminal Block  
• Do not wire anything to the release holes.  
(2) With the flat-blade screwdriver still inserted into the release hole,  
insert the wire into the terminal hole until it strikes the terminal  
block.  
Do not tilt or twist a flat-blade screwdriver while it is inserted into a release  
hole on the terminal block. The terminal block may be damaged  
.
(3) Remove the flat-blade screwdriver from the release hole.  
• Insert a flat-blade screwdriver into the release holes at an angle.  
The terminal block may be damaged if you insert the screwdriver  
straight in.  
Flat-blade screwdriver  
(3)  
(1)  
10 to 15°  
(3)  
• Do not allow the flat-blade screwdriver to fall out while it is inserted  
into a release hole.  
(1)  
(2)  
Stranded Wires  
Do not bend the wire past its natural bending radius or pull on it  
with excessive force. Doing so may cause the wire disconnection.  
Checking Connections  
• After insertion, pull gently on the wire to make sure that it will not  
come out (i.e., to confirm that it is held by the terminal block).  
• To prevent short circuits, insert the stripped part of a stranded  
wire or the conductive part of a ferrule until it is hidden inside the  
terminal insertion hole. (See following diagram.)  
Do not insert more than one wire into each terminal (insertion) hole  
.
• To prevent wiring materials from smoking or ignition, use the wiring  
materials given in the following table.  
Stripping length  
Ferrules  
When using  
terminal  
Ferrules  
When not using  
terminal  
Recommended Wire  
0.5 to 1.5 mm2/AWG20 to AWG16  
10 mm  
8 mm  
Note: Use Ferrules with UL certification (R/C).  
Disposal  
Do not dispose of the product by burning.  
21  
G2RV-SR/G3RV-SR  
2. Removing Wires from the Push-In Plus Terminal Block  
Use the following procedure to remove wires from the terminal block.  
The same method is used to remove stranded wires and ferrules.  
Screw Terminal  
• Screw terminal  
Applicable wire  
size  
Stripping  
length  
Wired type  
(1) Hold a flat-blade screwdriver at an angle and insert it into the  
release hole.  
(2) With the flat-blade screwdriver still inserted into the release hole,  
remove the wire from the terminal insertion hole.  
(3) Remove the flat-blade screwdriver from the release hole.  
Stranded wires, without  
ferrule  
0.5 to 1.5 mm2  
0.5 to 1.5 mm2  
0.5 to 1.5 mm2  
8 mm  
Stranded wires, with ferrule  
and plastic collar  
8 mm  
8 mm  
Flat-blade screwdriver  
Stranded wires with ferrule,  
without plastic collar  
(3)  
(1)  
10 to 15°  
Wire  
(3)  
(1)  
• Tightening Torque  
0.4 N · m  
(2)  
• Electric wiring  
Use the electric wire of specified size as shown above. The  
3. Recommended ferrules and tools  
Recommended Ferrules  
stripped wire length is 8 mm.  
Applicable  
Recommended ferrules  
Screw terminal  
Ferrules  
Conduct  
length  
wire  
Phoenix  
Contact  
product  
Weidmuller  
product  
(mm2) (AWG)  
Wago product  
(mm)  
8 mm  
0.5  
0.75  
1
20  
18  
18  
16  
8
8
8
8
AI0.5-8  
H0.5/14  
H0.75/14  
H1.0/14  
H1.5/14  
FE-0.5-8N-WH  
FE-0.75-8N-GY  
FE-1.0-8N-RD  
FE-1.5-8N-BK  
Stripping length  
AI0.75-8  
AI1-8  
<G2RV>  
1.5  
AI1.5-8  
Operating latching lever  
When operating the latching lever for G2RV-SR701/501  
series, use a 2.5 mm width flat-blade screwdriver.  
CRIMPFOX6  
CRIMPFOX6T-F PZ6 roto  
CRIMPFOX10S  
Recommended crimp  
tool  
Variocrimp4  
*1. Make sure that the outer diameter of the wire is smaller than the  
inner diameter of the insulating sleeve of the recommended  
ferrule.  
• Applicable flat-blade screwdriver  
Flat-blade screwdriver with parallel cutting edge: shaft diameter  
2.5 mm (3.0 mm max.)  
*2. Make sure that the ferrule processing dimensions conform to the  
following figure.  
Parallel cutting edge flat-blade screwdriver  
8 mm  
Shaft diameter 2.5 mm (3.0 mm max.)  
Wide flat-blade screwdriver  
8 mm  
2.1 mm max.  
Driver with a thick shaft cannot be used.  
Recommended Flat-blade Screwdriver  
Use a flat-blade screwdriver to connect and remove wires.  
Use the following flat-blade screwdriver.  
The following table is the manufacturer and format at the time in  
December 2015.  
• Always turn OFF the power supply before operating latching lever.  
• Return to its original state after using the latching lever.  
• Do not use the latching lever as a switch.  
• Operation durability of the latching lever is 100 times or more.  
• Do not keep the latching lever ON for a long period of time (24  
hours or more) in order to maintain the operation check function.  
Side  
Front  
2.5 mm dia.  
0.4 mm  
2.5 mm  
Model  
Manufacturer  
XW4Z-00B  
Omron  
Wera  
ESD0.40×2.5  
SZF 0.4×2.5  
Phoenix Contact  
0.4×2.5×75 302  
AEF.2.5×75  
210-719  
Wiha  
Facom  
Wago  
SDI 0.4×2.5×75  
Weidmuller  
22  
G2RV-SR/G3RV-SR  
<Relationship of SSR and duct (duct depth)>  
Method of operation of the latching lever  
Incorrect Example  
Countermeasure 1  
Countermeasure 2  
<Protective cover: locked> <Protective cover: disengage>  
Recommended height of the duct is  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Contact normal position  
1/2 or less of the height of the SSR  
Contact operating position (on-state)  
Duct or  
other object  
blocking  
airflow  
Airflow  
Height of SSR  
Close protective cover  
Open protective cover  
Vertical  
Direction  
Metal  
base  
SSR  
SSR  
SSR  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Duct or other object  
blocking airflow  
Do not enclose the SSR in a  
duct of the same height.  
It will interfere with the heat  
dissipation of SSR.  
Use ducts that have a  
shallow depth, to provide a place the SSR on a metal base so  
sufficient ventilation area. that it is not surrounded by the ducts.  
If the ducts cannot be made lower,  
Keep the protective cover open when using the latching lever. Move  
until the latching lever clicks to the ON position (ON state). After  
using the latching lever, in order to prevent malfunction, return the  
switch to contact normal position (OFF state), and make sure the  
protective cover is firmly closed.  
<Ventilation Outside the Control Panel>  
Be aware of airflow  
Duct or other object  
blocking airflow  
Using the latching lever  
Exhaust  
(Axial fan)  
Example: check the operation of the relay and the sequence circuit  
SSR  
SSR  
SSR  
<G3RV>  
• Since the G3RV uses electronic components, do not allow it to fall,  
vibrate, or apply shock that exceeds the criteria. Doing so may  
result in failure, malfunction, or deterioration of performance.  
• Tighten screw terminal for G3RV with a torque of 0.4 N · m. It may  
cause short-circuit failure or burning.  
Inlet  
• If the air inlet or air outlet has a filter, clean the filter regularly to  
prevent it from clogging to ensure an efficient flow of air.  
• Do not place objects that may obstruct the proper ventilation for  
outside or inside the inlet or exhaust port, and in the outside  
vicinity.  
• Please use the voltage and current suitable for the input and output  
terminal portion of G3RV. It may cause short-circuit failure or  
burning.  
Mounting  
• A heat exchanger, if used, should be located in front of the G3RV  
to ensure the efficiency of the heat exchanger.  
<The SSR Mounting Pitch (Panel Mounting)>  
Duct or other object blocking airflow  
• Please observe the ambient temperature of G3RV. The rated  
current of the G3RV is measured at an ambient temperature of  
25°C.  
60 mm min.  
10 mm min.  
SSR  
• The G3RV uses a semiconductor in the output element.  
This causes the temperature inside the control panel to increase  
due to heating resulting from the flow of electrical current through  
the load. The G3RV reliability can be increased by adding a  
ventilation fan to the control panel to dispel this heat, thus lowering  
the ambient temperature of the G3RV.  
Vertical Direction  
30 mm min.  
(It suggests that life expectancy is doubled by each 10°C reduction  
in ambient temperature.)  
80 mm min.  
EMI  
The G3RV is a Class A product (for industrial environments).  
When used in a residential environment, it may cause radio  
interference. In such case, the user may be required to take  
appropriate measures.  
* When five or more are installed, install with 10 mm space between  
each.  
23  
G2RV-SR/G3RV-SR  
For G2RV-SR/G3VR-SR  
Common Accessories (order separately)  
Ordering Information  
Short Bars  
Maximum  
energizing  
current  
No.of  
poles  
Minimum order  
(Quantity)  
Appearance  
Pitch  
Colors  
Model *  
2
PYDN-6.2-020@  
PYDN-6.2-030@  
PYDN-6.2-040@  
PYDN-6.2-100@  
PYDN-6.2-200@  
3
Red (R),  
Blue (S),  
Yellow (Y)  
6.2 mm  
4
10  
32 A  
10  
20  
Note: Use for wiring to the adjacent socket.  
* Replace the box (@) in the model number with the code for the covering color. @ color selection: R = red, S = blue, Y = yellow  
Labels  
Appearance  
Model  
Minimum order  
5 sheets  
(1 sheet/72 pieces)  
XW5Z-P2.5LB2  
Separate Plate  
Appearance  
Model  
XW5Z-EP12  
PLC interface unit  
Appearance  
I/O classification  
Common process  
Connection method  
Push-In  
Model  
P2RVC-8-I-5-1  
P2RVC-8-I-7-1  
P2RVC-8-I-5  
PNP  
For input  
Screw  
NPN  
PNP  
NPN  
Push-In  
Push-In  
P2RVC-8-O-5-1  
P2RVC-8-O-7-1  
P2RVC-8-O-5  
For output  
Screw  
Push-In  
Parts for DIN Track Mounting  
Minimum order  
(Quantity)  
Appearance  
Type  
Model  
1 m  
PFP-100N  
DIN Tracks  
0.5 m  
PFP-50N  
End Plate*  
PFP-M  
PFP-S  
10  
Spacer  
* When mounting components to DIN rail, prevent sliding using end plates (Model PFP-M).  
Refer to your OMRON website for details on PFP-@.  
24  
G2RV-SR/G3RV-SR  
Applicable Cables  
Cable  
length L  
(mm)  
Name  
Appearance  
Connecting Cables  
Applicable Connectors  
1,000  
2,000  
3,000  
5,000  
P2RV-A100C  
P2RV-A200C  
P2RV-A300C  
P2RV-A500C  
End A  
Device  
end  
End B  
PLC interface  
unit end  
Cables with Loose  
Wires  
P2RV-A@C  
8 I/O  
points  
Various devices  
L
70  
1,000  
2,000  
3,000  
5,000  
1,000  
2,000  
3,000  
5,000  
1,000  
2,000  
3,000  
5,000  
P2RV-4-100C  
P2RV-4-200C  
Cables with  
Connectors (1:4)  
P2RV-4-@C  
32 output  
points  
PLC I/O Units with MIL connectors (1:4)  
CJ1W-OD232/OD262, etc.  
P2RV-4-300C  
P2RV-4-500C  
P2RV-4-100IMC  
P2RV-4-200IMC  
P2RV-4-300IMC  
P2RV-4-500IMC  
P2RV-4-100IFC  
P2RV-4-200IFC  
P2RV-4-300IFC  
P2RV-4-500IFC  
L
L
L
300  
300  
300  
Cables with  
Connectors (1:4)  
P2RV-4-@IMC  
32 input  
points  
PLC I/O Units with MIL connectors (1:4)  
CJ1W-ID232/ID262, etc.  
Cables with  
Connectors (1:4)  
P2RV-4-@IFC  
32 input  
points  
PLC I/O Units with Fujitsu connectors (1:4)  
CJ1W-ID231/ID261, etc.  
500  
1,000  
500  
P2RV-A050C-OMR GRT1  
P2RV-A100C-OMR GRT1  
P2RV-A050IC-OMR GRT1  
P2RV-A100IC-OMR GRT1  
P2RV-A050C-OMR NX  
P2RV-A100C-OMR NX  
P2RV-A050IC-OMR NX  
P2RV-A100IC-OMR NX  
8 output  
Cables with Connectors points  
(1:1)  
Slice I/O Units (1:1)  
For inputs: GRT1-ID8-1  
For outputs: GRT1-OD8-1  
P2RV-A  
@
C-OMR GRT1 8 input  
points  
L
L
1,000  
500  
8 output  
points  
Cables with  
Connectors (1:1)  
PLC I/O Units with MIL connectors (1:1)  
For inputs: NX-ID4442  
For outputs: NX-OD4256  
1,000  
500  
P2RV-A@C-OMR NX 8 input  
points  
1,000  
25  
G2RV-SR/G3RV-SR  
Cable  
length L  
(mm)  
Name  
Appearance  
Connecting Cables  
Applicable Connectors  
500  
P2RV-050C-SCH-A  
P2RV-100C-SCH-A  
P2RV-200C-SCH-A  
P2RV-300C-SCH-A  
P2RV-500C-SCH-A  
P2RV-050C-SCH-B  
P2RV-100C-SCH-B  
P2RV-200C-SCH-B  
P2RV-300C-SCH-B  
P2RV-500C-SCH-B  
P2RV-050C-SCH-C  
P2RV-100C-SCH-C  
P2RV-200C-SCH-C  
P2RV-300C-SCH-C  
P2RV-500C-SCH-C  
P2RV-050C-SCH-D  
P2RV-100C-SCH-D  
P2RV-200C-SCH-D  
P2RV-300C-SCH-D  
P2RV-500C-SCH-D  
P2RV-050C-SIM-A  
P2RV-100C-SIM-A  
P2RV-200C-SIM-A  
P2RV-300C-SIM-A  
P2RV-500C-SIM-A  
P2RV-050C-SIM-B  
P2RV-100C-SIM-B  
P2RV-200C-SIM-B  
P2RV-300C-SIM-B  
P2RV-500C-SIM-B  
End A  
Device  
end  
End B  
PLC interface  
unit end  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
Schneider Electric PLCs with 32-point  
connectors (1:4)  
For inputs: 140 DDI 353 00  
For outputs: 140 DDO 353 00  
1,000  
2,000  
3,000  
5,000  
500  
32 output  
points  
Schneider Electric  
PLC Connecting  
Cables  
L
300  
P2RV-@C-SCH-@  
1,000  
2,000  
3,000  
5,000  
500  
16 input  
points  
Schneider Electric PLCs with  
16-point connectors (1:2)  
For inputs: BMX DDI 1602  
For outputs: BMX DDO 1602  
1,000  
2,000  
3,000  
5,000  
500  
16 output  
points  
L
300  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
Siemens PLCs with  
32-point connectors (1:4)  
For inputs: 6ES7 321-1BL00-0AA0  
For outputs: 6ES7 322-1BL00-0AA0  
1,000  
2,000  
3,000  
5,000  
32 output  
points  
L
L
L
300  
300  
300  
500  
P2RV-050C-SIM-C  
P2RV-100C-SIM-C  
P2RV-200C-SIM-C  
P2RV-300C-SIM-C  
P2RV-500C-SIM-C  
1,000  
2,000  
3,000  
5,000  
Siemens PLC  
16 input  
Siemens PLCs with  
16-point connectors (1:2)  
For inputs: 6ES7 321-1BH02-0AA0  
Connecting Cables  
points  
P2RV-@C-SIM-@  
500  
P2RV-050C-SIM-D  
P2RV-100C-SIM-D  
P2RV-200C-SIM-D  
P2RV-300C-SIM-D  
P2RV-500C-SIM-D  
P2RV-050C-SIM-E  
P2RV-100C-SIM-E  
P2RV-200C-SIM-E  
P2RV-300C-SIM-E  
P2RV-500C-SIM-E  
1,000  
2,000  
3,000  
5,000  
500  
32 input  
points  
Siemens PLCs with  
32-point connectors (1:4)  
For inputs: 6ES7 421-1BL-0AA0  
For outputs: 6ES7 422-1BL-0AA0  
1,000  
2,000  
3,000  
5,000  
32 output  
points  
26  
G2RV-SR/G3RV-SR  
PLC interface unit  
Ratings / characteristics  
Rated voltage  
Rated current  
30 VAC/DC  
0.5 A/poles, 2 A/unit  
Ambient operating  
temperature  
40 to 55°C  
Electrical schematic  
Input  
P2RVC-8-I-@-1 (PNP)  
P2RVC-8-I-5 (NPN)  
1....................8  
1....................8  
14  
14  
11  
11  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
Output  
P2RVC-8-O-@-1 (PNP)  
P2RVC-8-O-5 (NPN)  
1....................8  
1....................8  
A2  
A2  
A1  
A1  
1
2
3
4
5
6
7
8
9
10  
1
2
3
4
5
6
7
8
9
10  
27  
G2RV-SR/G3RV-SR  
Dimensions  
(unit: mm)  
PLC interface unit  
Push-IN  
P2RVC-8-I-5(-1)  
P2RVC-8-O-5(-1)  
49.60  
67.16  
12.68  
7×6.20  
29  
Screw  
P2RVC-8-I-7-1  
P2RVC-8-O-7-1  
49.60  
67.16  
12.68  
7×6.20  
29  
28  
G2RV-SR/G3RV-SR  
(Except for PLC interface unit)  
Common Accessories  
Dimensions  
(unit: mm)  
Short Bars  
PYDN-6.2-@@ (6.2 mm)  
Maximum carry  
Pitch  
No. of poles  
L (Length)  
Colors  
Model *  
current  
2
3
12.4  
18.6  
24.8  
62  
PYDN-6.2-020@  
PYDN-6.2-030@  
PYDN-6.2-040@  
PYDN-6.2-100@  
PYDN-6.2-200@  
2
1.20  
9
L
Red (R)  
Blue (S)  
Yellow (Y)  
6.2 mm  
4
32 A  
14  
10  
20  
124  
6.20  
Note: Use the Short Bars for crossover wiring within one Socket or between Sockets.  
* Replace the box (@) in the model number with the code for the covering color.  
Separate Plate  
XW5Z-EP12  
56  
12  
63  
Parts for DIN Track Mounting  
Refer to your OMRON website for details on the PFP-@.  
29  
Terms and Conditions of Sale  
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed  
part of all quotes, agreements, purchase orders, acknowledgments, price lists,  
catalogs, manuals, brochures and other documents, whether electronic or in  
writing, relating to the sale of products or services (collectively, the "Products")  
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron  
objects to any terms or conditions proposed in Buyer’s purchase order or other  
documents which are inconsistent with, or in addition to, these Terms.  
2. Prices; Payment Terms. All prices stated are current, subject to change with-  
out notice by Omron. Omron reserves the right to increase or decrease prices  
on any unshipped portions of outstanding orders. Payments for Products are  
due net 30 days unless otherwise stated in the invoice.  
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.  
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR  
INTENDED USE. Omron further disclaims all warranties and responsibility of  
any type for claims or expenses based on infringement by the Products or oth-  
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-  
gation hereunder shall be, at Omron’s election, to (i) replace (in the form  
originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying  
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of  
the non-complying Product; provided that in no event shall Omron be responsi-  
ble for warranty, repair, indemnity or any other claims or expenses regarding  
the Products unless Omron’s analysis confirms that the Products were prop-  
erly handled, stored, installed and maintained and not subject to contamina-  
tion, abuse, misuse or inappropriate modification. Return of any Products by  
Buyer must be approved in writing by Omron before shipment. Omron Compa-  
nies shall not be liable for the suitability or unsuitability or the results from the  
use of Products in combination with any electrical or electronic components,  
circuits, system assemblies or any other materials or substances or environ-  
ments. Any advice, recommendations or information given orally or in writing,  
are not to be construed as an amendment or addition to the above warranty.  
See http://www.omron247.com or contact your Omron representative for pub-  
lished information.  
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices  
sent to Buyer after deducting transportation charges, taxes and duties, and will  
be allowed only if (i) the invoice is paid according to Omron’s payment terms  
and (ii) Buyer has no past due amounts.  
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or  
the maximum legal rate, whichever is less, on any balance not paid within the  
stated terms.  
5. Orders. Omron will accept no order less than $200 net billing.  
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all  
costs involved in, obtaining any government approvals required for the impor-  
tation or sale of the Products.  
7. Taxes. All taxes, duties and other governmental charges (other than general  
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE  
imposed directly or indirectly on Omron or required to be collected directly or  
indirectly by Omron for the manufacture, production, sale, delivery, importa-  
tion, consumption or use of the Products sold hereunder (including customs  
duties and sales, excise, use, turnover and license taxes) shall be charged to  
and remitted by Buyer to Omron.  
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY  
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS  
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual  
price of the Product on which liability is asserted.  
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory  
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and  
security or payment in advance. If Buyer fails to make payment or otherwise  
comply with these Terms or any related agreement, Omron may (without liabil-  
ity and in addition to other remedies) cancel any unshipped portion of Prod-  
ucts sold hereunder and stop any Products in transit until Buyer pays all  
amounts, including amounts payable hereunder, whether or not then due,  
which are owing to it by Buyer. Buyer shall in any event remain liable for all  
unpaid accounts.  
their employees from and against all liabilities, losses, claims, costs and  
expenses (including attorney's fees and expenses) related to any claim, inves-  
tigation, litigation or proceeding (whether or not Omron is a party) which arises  
or is alleged to arise from Buyer's acts or omissions under these Terms or in  
any way with respect to the Products. Without limiting the foregoing, Buyer (at  
its own expense) shall indemnify and hold harmless Omron and defend or set-  
tle any action brought against such Companies to the extent based on a claim  
that any Product made to Buyer specifications infringed intellectual property  
rights of another party.  
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation  
unless Buyer indemnifies Omron against all related costs or expenses.  
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-  
resulting from causes beyond its control, including earthquakes, fires, floods,  
strikes or other labor disputes, shortage of labor or materials, accidents to  
machinery, acts of sabotage, riots, delay in or lack of transportation or the  
requirements of any government authority.  
sive property of Omron Companies and Buyer shall not attempt to duplicate it  
in any way without the written permission of Omron. Notwithstanding any  
charges to Buyer for engineering or tooling, all engineering and tooling shall  
remain the exclusive property of Omron. All information and materials supplied  
by Omron to Buyer relating to the Products are confidential and proprietary,  
and Buyer shall limit distribution thereof to its trusted employees and strictly  
prevent disclosure to any third party.  
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:  
a.Shipments shall be by a carrier selected by Omron; Omron will not drop ship  
except in “break down” situations.  
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and  
constitute delivery to Buyer;  
licenses regarding (i) export of products or information; (iii) sale of products to  
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of  
regulated technology or information.  
c. All sales and shipments of Products shall be FOB shipping point (unless oth-  
erwise stated in writing by Omron), at which point title and risk of loss shall  
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right  
est in the Products until the full purchase price is paid;  
d.Delivery and shipping dates are estimates only; and  
e.Omron will package Products as it deems proper for protection against nor-  
mal handling and extra charges apply to special conditions.  
and no course of dealing between Buyer and Omron shall operate as a waiver  
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder  
without Omron's written consent. (c) Law. These Terms are governed by the  
law of the jurisdiction of the home office of the Omron company from which  
Buyer is purchasing the Products (without regard to conflict of law princi-  
ples). (d) Amendment. These Terms constitute the entire agreement between  
Buyer and Omron relating to the Products, and no provision may be changed  
or waived unless in writing signed by the parties. (e) Severability. If any provi-  
sion hereof is rendered ineffective or invalid, such provision shall not invalidate  
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts  
against the amount owing in respect of this invoice. (g) Definitions. As used  
herein, “including” means “including without limitation”; and “Omron Compa-  
nies” (or similar words) mean Omron Corporation and any direct or indirect  
subsidiary or affiliate thereof.  
12. Claims. Any claim by Buyer against Omron for shortage or damage to the  
Products occurring before delivery to the carrier must be presented in writing  
to Omron within 30 days of receipt of shipment and include the original trans-  
portation bill signed by the carrier noting that the carrier received the Products  
from Omron in the condition claimed.  
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the  
Products will be free from defects in materials and workmanship for a period of  
twelve months from the date of sale by Omron (or such other period expressed  
in writing by Omron). Omron disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,  
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-  
Certain Precautions on Specifications and Use  
1. Suitability of Use. Omron Companies shall not be responsible for conformity  
with any standards, codes or regulations which apply to the combination of the  
Product in the Buyer’s application or use of the Product. At Buyer’s request,  
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-  
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the  
ratings and limitations of use which apply to the Product. This information by  
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs  
user’s programming of a programmable Product, or any consequence thereof.  
uct in combination with the end product, machine, system, or other application  
or use. Buyer shall be solely responsible for determining appropriateness of  
the particular Product with respect to Buyer’s application, product or system.  
Buyer shall take application responsibility in all cases but the following is a  
non-exhaustive list of applications for which particular attention must be given:  
and other materials is provided as a guide for the user in determining suitabil-  
ity and does not constitute a warranty. It may represent the result of Omron’s  
test conditions, and the user must correlate it to actual application require-  
ments. Actual performance is subject to the Omron’s Warranty and Limitations  
of Liability.  
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be  
interference, or conditions or uses not described in this document.  
(ii) Use in consumer products or any use in significant quantities.  
(iii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety equip-  
ment, and installations subject to separate industry or government regulations.  
(iv) Systems, machines and equipment that could present a risk to life or prop-  
erty. Please know and observe all prohibitions of use applicable to this Prod-  
uct.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Omron’s representative at any time  
to confirm actual specifications of purchased Product.  
5. Errors and Omissions. Information presented by Omron Companies has been  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors or omissions.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO  
OMRON AUTOMATION AMERICAS HEADQUARTERS • Chicago, IL USA 847.843.7900 800.556.6766 www.omron247.com  
OMRON CANADA, INC. • HEAD OFFICE  
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com  
OMRON ARGENTINA • SALES OFFICE  
Cono Sur • 54.11.4783.5300  
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE  
México DF • 52.55.59.01.43.00 • 01-800-226-6766 • mela@omron.com  
OMRON CHILE • SALES OFFICE  
Santiago • 56.9.9917.3920  
OMRON ELECTRONICS DE MEXICO • SALES OFFICE  
Apodaca, N.L. • 52.81.11.56.99.20 • 01-800-226-6766 • mela@omron.com  
OTHER OMRON LATIN AMERICA SALES  
54.11.4783.5300  
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE  
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br  
OMRON EUROPE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. +31 (0) 23 568 13 00 www.industrial.omron.eu  
Authorized Distributor:  
Controllers & I/O  
• Machine Automation Controllers (MAC) • Motion Controllers  
• Programmable Logic Controllers (PLC) • Temperature Controllers • Remote I/O  
Robotics  
• Industrial Robots • Mobile Robots  
Operator Interfaces  
• Human Machine Interface (HMI)  
Motion & Drives  
• Machine Automation Controllers (MAC) • Motion Controllers • Servo Systems  
• Frequency Inverters  
Vision, Measurement & Identification  
• Vision Sensors & Systems • Measurement Sensors • Auto Identification Systems  
Sensing  
• Photoelectric Sensors • Fiber-Optic Sensors • Proximity Sensors  
• Rotary Encoders • Ultrasonic Sensors  
Safety  
• Safety Light Curtains • Safety Laser Scanners • Programmable Safety Systems  
• Safety Mats and Edges • Safety Door Switches • Emergency Stop Devices  
• Safety Switches & Operator Controls • Safety Monitoring/Force-guided Relays  
Control Components  
• Power Supplies • Timers • Counters • Programmable Relays  
• Digital Panel Meters • Monitoring Products  
Switches & Relays  
• Limit Switches • Pushbutton Switches • Electromechanical Relays  
• Solid State Relays  
Software  
• Programming & Configuration • Runtime  
J285I-E-01 06/16  
Note: Specifications are subject to change.  
© 2016 Omron. All Rights Reserved.  
Printed in U.S.A.  
Printed on recycled paper.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY