G3VM-201G2 [OMRON]
Transistor Output SSR,;型号: | G3VM-201G2 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Transistor Output SSR, 输出元件 光电 |
文件: | 总3页 (文件大小:665K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G3VM-201G2
Ultrasensitive MOS FET Relays in 200-V Load series
for electric power saving.
MOS FET Relays
• Continuous load current of 200 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■Application Examples
■
Terminal Arrangement/Internal Connections
4
3
• Communication equipment
• Test & Measurement equipment
• Security equipment
Mold pin
mark *
OMRON logo
-201G2
Model name
932
LOT.No.
Pin 1 mark
• Amusement equipment
• Industrial equipment
1
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
• Various battery-driven devices
■List of Models
Minimum package quantity
Model
Load voltage
(peak value) *
Package type Contact form
Terminals
Surface-mounting Terminals
Number per tube Number per tape and reel
G3VM-201G2
100
-
-
1a
SOP4
200 V
(SPST-NO)
G3VM-201G2 (TR)
2,500
* The AC peak and DC value are given for the load voltage.
■Absolute Maximum Ratings (Ta = 25°C)
Item
Symbol
IF
IFP
Rating
30
1
Unit
mA
A
Measurement conditions
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
100 μs pulses, 100 pps
ΔIF/°C
VR
−0.3
5
mA/°C Ta ≥ 25°C
V
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
TJ
VOFF
IO
ΔIO/°C
IOP
125
200
200
−2.0
°C
V
mA
mA/°C Ta ≥ 25°C
A
0.6
t = 100 ms, Duty = 1/10
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
TJ
VI-O
Ta
Tstg
-
125
°C
Vrms
°C
°C
°C
1500
−40 to +85
−55 to +125
260
AC for 1 min
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
With no icing or condensation
With no icing or condensation
10 s
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum Unit
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
IO = 200 mA
IOFF = 100 μA
LED forward voltage
Reverse current
VF
IR
CT
IFT
IFC
RON
ILEAK
Coff
CI-O
RI-O
tON
1.1
-
-
-
0.1
-
-
-
1.27
-
30
-
-
5
1.4
10
-
0.2
-
8
1000
-
-
-
10
5
V
Note: 2. Turn-ON and Turn-OFF Times
μA
pF
mA
mA
Ω
nA
pF
pF
MΩ
ms
ms
IF
1
4
RL
Capacity between terminals
Trigger LED forward current
Turn-OFF LED forward current
Maximum resistance with output ON
Current leakage when the relay is open
Capacity between terminals
Capacity between I/O terminals
Insulation resistance between I/O terminals
Turn-ON time
VDD
VOUT
2
3
IF
= 0.5mA, IO = 200 mA, t < 1 s
1
VOFF = 200 V
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
IF = 0.5 mA, RL = 200 Ω,
VDD = 20 V (See note 2.)
90
0.8
108
3.5
1
IF
-
1000
-
-
90%
VOUT
10%
tON
tOFF
Turn-OFF time
tOFF
1
G3VM-201G2
MOS FET Relays
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
-
-
-
-
0.5
-
160
25
160
65
V
mA
mA
°C
IO
Ta
−20
-
■Engineering Data
LED forward current vs. LED forward voltage
LED forward current vs. Ambient temperature
Continuous load current vs. Ambient temperature
I
O
- Ta
IF
- VF
I
F
- Ta
250
200
150
100
50
50
40
30
20
10
0
100
10
1
Ta = 25°C
0
0.1
-40 -20
0
20
40
60
80 100
-40 -20
0
20
40
60
80 100
0.8
1
1.2
1.4
1.6
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Ambient temperature Ta (°C)
On-state resistance vs. Ambient temperature Trigger LED forward current vs. Ambient temperature
Continuous load current vs. On-state voltage
IO
- VON
R
ON - Ta
IFT - Ta
10
8
0.2
0.1
0
300
200
100
0
Ta = 25 °C
IO= 200 mA
IF= 0.5 mA, t < 1 s
IO= 200 mA
t < 1 s
IF= 1 mA, t < 1 s
6
4
-100
-200
-300
2
0
-40 -20
0
20
40
60
80 100
-40 -20
0
20
40
60
80 100
-1
-0.5
0
0.5
1
On-state voltage VON (V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Current leakage vs. Ambient temperature
Turn ON, Turn OFF time vs. Ambient temperature
Turn ON, Turn OFF time vs. LED forward current
ILEAK - Ta
tON, tOFF - I
F
tON, tOFF - Ta
100
10
10
VOFF =200V
10
tON
tOFF
1
1
1
0.1
0.01
0.1
tON
VDD = 20 V
RL= 200 Ω
Ta = 25 °C
VDD= 20 V
RL= 200 Ω
IF = 0.5 mA
tOFF
0.01
0.1
-40 -20
0
20
40
60
80 100
0.1
1
10
100
(mA)
-40 -20
0
20
40
60
80 100
Ambient temperature Ta (°C)
LED forward current I
F
Ambient temperature Ta (°C)
Current leakage vs. Load voltage
ILEAK - VOFF
0.5
0.4
0.3
0.2
0.1
0
Ta = 25 °C
0
50
100
150
200
Load voltage VOFF(v)
■Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP4 type
■Appearance
SOP (Small Outline Package)
SOP4
Mold pin mark *
OMRON logo
-201G2
Model name
LOT.No.
932
Pin 1 mark
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.1 g
0.2ꢀ
4.4
(Recommended Value, TOP VIEW)
0.2
3.9
2.1 max.
0.1ꢀ
6 to 6.3
1.2
0.8
0.1
0.4
0.3
0.6
0.1
0.1
0.4
7.0
2.ꢀ4
0.2ꢀ
2.ꢀ4
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K257-E1-03
1014(0613)(O)
相关型号:
©2020 ICPDF网 联系我们和版权申明