G6K-2P-TR-DC5 [OMRON]

Power/Signal Relay;
G6K-2P-TR-DC5
型号: G6K-2P-TR-DC5
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay

文件: 总10页 (文件大小:1056K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
GLow6SigKnal Relay  
• Compact fourth generation design, offers excellent board  
space savings.  
• Available in 2.54 and 3.2 mm coil-contact terminal spacing.  
• “-Y” models meet 2.5 kV Bellcore surge requirements.  
• Conforms to FCC Part 68.  
Terminal design based on Omron’s successful G6S relay.  
• Available in PCB through-hole, SMT gullwing and SMT  
“inside-Lterminals.  
• UL recognized / CSA certified.  
• Available in single coil latching.  
• RoHS Compliant.  
RC  
Ordering Information  
To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5).  
Terminal  
Contact form  
Model  
Non-latching  
2.54 mm spacing  
Non-latching  
3.2 mm coil-contact  
terminal spacing  
Single coil latching  
3.2 mm coil-contact  
terminal spacing  
Gullwing  
DPDT  
G6K-2F  
G6K-2F-Y  
G6KU-2F-Y  
Inside “L”  
G6K-2G  
G6K-2P  
G6K-2G-Y  
G6K-2P-Y  
G6KU-2G-Y  
G6KU-2P-Y  
PCB through-hole  
When ordering tape packing (surface mount versions), add “-TR” to the model number (e.g., G6K-2G-TR-DC5)  
Specifications  
Contact Data  
Load  
Resistive load (cosφ=1)  
0.3 A at 125 VAC  
1 A at 30 VDC  
Ag (Au clad)  
Rated load  
Contact material  
Max. carry current  
1 A  
Max. operating voltage  
Max. operating current  
Max. switching capacity  
Min. permissible load (See note)  
125 VAC, 60 VDC  
1 A  
37.5 VA, 30W  
10 μA at 10 mVDC  
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary  
depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions.  
Low Signal Relay G6K  
53  
Coil Data  
G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P)  
G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y)  
Rated voltage Rated current Coil resistance  
(VDC) (mA) (Ω)  
Pick-up voltage  
Dropout voltage  
% of rated value  
10% min.  
Maximum voltage Powerconsumption  
(mW)  
3
33.0  
23.2  
21.1  
17.6  
11.3  
9.1  
91  
80% max.  
150% max.  
Approx. 100  
@ 23°C to 70°C  
4.5  
5
194  
237  
341  
795  
1,315  
5,220  
6
9
12  
24  
4.6  
G6KU- 3.2 mm spacing, single coil latching (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y)  
Rated voltage Rated current Coil resistance  
(VDC) (mA) (Ω)  
Set-up voltage  
Reset voltage  
% of rated value  
75% min.  
Maximum voltage Powerconsumption  
(mW)  
3
33.0  
23.2  
21.1  
17.6  
11.3  
9.1  
91  
75% max.  
150% max.  
Approx. 100  
@ 23°C to 70°C  
4.5  
5
194  
237  
341  
795  
1,315  
5,220  
6
9
12  
24  
4.6  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.  
2. The operating characteristics are measured at a coil temperature of 23°C unless otherwise specified.  
3. Pick-up voltage will vary with temperature  
4. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously.  
Characteristics  
Contact resistance (See note 1)  
Operate (set) time (See note 2)  
Release (set) time (See note 2)  
Insulation resistance (See note 3)  
Dielectric strength  
100 mΩ max.  
3 ms max. (Approx. 1.4 ms - standard. Approx. 1.2 ms - latching)  
3 ms max. (Approx. 1.3 ms - standard. Approx. 1.2 ms - latching)  
1,000 MΩ min. (at 500 VDC)  
1,500 VAC for 1 minute between coil contacts  
1,000 VAC for 1 minute between contacts of different poles  
750 VAC for 1 minute between contacts of the same pole  
2,500 V, (2 x 10 μs) between coil and contacts.  
(Conforms to Bellcore specifications)  
Surge withstand voltage “-Y’ versions  
Standard versions  
1,500 V, (10 x 160 μs) between coil and contacts / contacts of different and same polarity.  
(Conforms to FCC Part 68)  
Vibration  
Shock  
Mechanical durability 10 to 55 Hz; 5.0 mm double amplitude  
Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude  
1,000 m/s2 (approx. 100G)  
750 m/s2 (approx. 75G)  
Mechanical durability  
Malfunction durability  
Ambient temperature  
Humidity  
-40°C to 70°C with no icing or condensation  
5 to 85% RH  
Service life  
Mechanical  
Electrical  
50,000,000 operations min. (at 36,000 operations per hour)  
100,000 operations min. at rated load (at 1,800 operations per hour)  
Approx. 0.7 g  
Weight  
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method.  
2. Values in parentheses are typical values unless otherwise stated.  
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength.  
4. Data shown are of initial value.  
54  
Low Signal Relay G6K  
Characteristic data  
Maximum Switching Capacity  
Ambient Temperature vs.  
Maximum Coil Voltage  
Ambient Temperature vs.  
Switching Current  
AC resistive load  
DC resistive load  
Ambient temperature (°C)  
Ambient temperature (°C)  
Rated operating voltage (V)  
Note: The maximum coil voltage refers to the maxi-  
mum value in a varying range of operating  
power voltage, not a continuous voltage.  
Ambient Temperature vs. Must  
Electrical Service Life  
Ambient Temperature vs. Must  
Operate or Must Release Voltage  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Set or Must Reset Voltage  
G6KU-2G (F/P)-Y  
Max. estimated value  
Max. estimated value  
30 VDC resistive load  
Ambient temperature: 23°C  
Switching frequency:  
1,800 operations/hour  
125 VAC resistive load  
Ambient temperature: 23°C  
Switching frequency:  
1,800 operations/hour  
Operate voltage  
Release voltage  
Ambient temperature (°C)  
Ambient temperature (°C)  
Rated operating current (A)  
Electrical Service Life  
Shock Malfunction  
Electrical Service Life  
(Contact Resistance) (See note.)  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(with Must Operate and Must  
Release Voltage) (See note.)  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Energized  
NO  
Sample: G6K-2G  
Sample: G6K-2G  
contact  
Not  
energized  
Number of Relays: 10  
Number of Relays: 10  
NC  
contact  
Test conditions: 1 A resistive load at  
30 VDC with an operation rate of 50%  
Switching frequency: 1,800 operations/h  
Test conditions: 1 A resistive load  
at 30 VDC with an operation rate of 50%  
Switching frequency: 1,800 operations/h  
Must operate  
Contact resistance  
Shock direction  
Unit: m/s 2  
Sample: G6K-2G  
Number of Relays: 10  
Must release  
Conditions: Shock is applied in X, Y, and Z di  
rections three times each with and with  
out energizing the Relays to check the  
number of contact malfunctions.  
Operating frequency (x103operations)  
3
Operating frequency (x10 operations)  
Note: The tests were conducted at an  
ambient temperature of 23°C.  
Note: The tests were conducted at an  
ambient temperature of 23°C.  
Low Signal Relay G6K  
55  
Mutual Magnetic Interference  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Mutual Magnetic Interference  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Contact Reliability Test (See note.)  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
NO  
Sample: G6K-2G  
Initial stage  
Test  
contact  
NC  
Number of Relays: 10  
Initial stage  
Test  
Test conditions: 10 mA resistive load at  
10 mVDC with an operation rate of 50 %  
Switching frequency: 7,200 operations/h  
contact  
Sample  
Sample  
Not energized  
Not energized  
Average value  
Test  
Average value  
Initial stage  
Initial stage  
Test  
Sample  
Sample  
Energized  
Energized  
Average value  
Average value  
Operating frequency (x103operations)  
Note 1: The test was conducted at an ambient temperature of 23°C.  
2: The contact resistance data are periodically measured reference values and are not values from each monitoring operation.  
Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check  
operation under the actual operating conditions before use.  
External Magnetic Interference  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Average value)  
(Average value)  
(Average value)  
Sample: G6K-2G  
Number of Relays: 10  
Sample: G6K-2G  
Number of Relays: 10  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
Sample: G6K-2G  
Number of Relays: 10  
Must operate voltage  
Must release voltage  
External magnetic field (A/m)  
External magnetic field (A/m)  
External magnetic field (A/m)  
High-frequency Characteristics High-frequency Characteristics High-frequency Characteristics  
(Isolation)  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Insertion Loss)  
G6K-2G (F/P), G6K-2G (F/P)-Y  
(Return Loss)  
G6K-2G (F/P),G6K-2G (F/P)-Y  
(Average value)  
(Average value)  
(Average value)  
0
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
1.4  
Sample: G6K-2G  
Sample: G6K-2G  
Number of Relays: 10  
Number of Relays: 10  
10  
20  
30  
40  
50  
60  
70  
80  
1.35  
1.3  
0.1  
1.25  
1.2  
0.2  
0.3  
0.4  
0.5  
Return loss  
1.15  
1.1  
1.05  
1
Sample: G6K-2G  
Number of Relays: 10  
V.SWR  
1
10  
100  
1
10  
100  
1
10  
100  
Frequency (MHz)  
Frequency (MHz)  
Frequency (MHz)  
Note: 1. The tests were conducted at an ambient temperature of 23°C.  
2. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics including  
endurance in the actual machine before use.  
56  
Low Signal Relay G6K  
Must Operate and Must Release Must Operate and Must Release  
Vibration Resistance  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Time Distribution (See note.)  
Bounce Time Distribution (See note.)  
G6K-2G (F/P) , G6K-2G (F/P)-Y  
G6K-2G (F/P), G6K-2G (F/P)-Y  
Sample: G6K-2G  
Must operate  
bounce time  
Must release  
bounce time  
Must operate  
Number of Relays:  
50  
Must release time  
Must operate voltage  
Must release voltage  
Sample: G6K-2G  
Number of Relays: 50  
After test  
Time (ms)  
Time (ms)  
Note: The tests were conducted at an ambient temperature of 23°C.  
Approvals  
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C  
Contact form  
Coil rating  
3 to 24 VDC  
Contact ratings  
Number of test operations  
6,000  
DPDT  
1 A at 30 VDC (Resistive)  
0.5 A at 60 VDC (Resistive)  
0.3 A at 125 VAC (General Use)  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6K-2F  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Top View) Terminal Arrangement/  
G6K-2G  
G6K-2P  
Internal Connections  
(Top View)  
Tolerance: 0.1 mm  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Bottom View)  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: 0.1 mm  
Eight, 0.8-dia. holes  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Low Signal Relay G6K  
57  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6K-2F-Y  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
G6K-2G-Y  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Bottom View) Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: 0.1 mm  
G6K-2P-Y  
Eight,  
0.8-dia. holes  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
G6KU-2F-Y  
G6KU-2G-Y  
G6KU-2P-Y  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
Mounting Dimensions (Bottom View) Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Tolerance: 0.1 mm  
Eight, 0.8-dia. holes  
Orientation mark  
Note: Each value has a tolerance of 0.3 mm.  
58  
Low Signal Relay G6K  
Packaging Information  
Tube packing  
Standard nomenclature  
50 pcs per anti-static tube  
900 pcs per reel  
2 reels per box  
Tape packing  
(SMT versions, only)  
When ordering, add “TR” before the rated coil voltage (e.g., G6K-2G-TR-DC5).  
Note: TR is not part of the relay model number and will not be marked on the relay.  
Order in box multiples  
(see details below)  
Relays in tube packing are arranged so that the orientation mark of each Relay is on the left side.  
Be sure to reference Relay orientation when mounting the Relay to the PCB.  
Orientation of Relays  
Stopper (gray)  
Stopper (green)  
Tube length: 520 mm (stopper not included)  
No. of Relays per Tube: 50  
Tape and Reel Dimensions (Surface Mount Models)  
Tape type: ETX7200 (EIAJ - Electronic Industrial Association of Japan)  
Reel type: RPM-16D (EIAJ, 330 mm diameter)  
Relays per reel: 900  
3. Carrier Tape Dimensions  
G6K-2F, G6K-2F-Y, G6KU-2F-Y  
1. Direction of Relay Insertion  
Orientation mark  
Top tape  
(cover tape)  
Pulling  
direction  
Carrier tape  
Emboss  
tape  
G6K-2G, G6K-2G-Y, G6KU-2G-Y  
2. Reel Dimensions  
Low Signal Relay G6K  
59  
Recommended Soldering Method  
Temperature indicates the surface temperature of the PCBs.  
IRS Method (for surface mounting terminal models)  
(1) IRS Method (Mounting Solder: Lead)  
(2) IRS Method (Mounting Solder: Lead-free)  
Upper surface of case (peak):  
255˚C max.  
Soldering  
250 max.  
Soldering  
230  
220 to  
245  
180  
180 to  
200  
Preheating  
150  
Relay  
terminal  
section  
Preheating  
150  
120 max.  
30 max.  
Time (s)  
20 to 30  
90 to 120  
Note: The temperature profile indicates the  
temperature of the relay terminal  
section.  
Time (s)  
The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern.  
In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side.  
Correct Soldering  
Incorrect Soldering  
Relay  
Insufficient  
amount of  
solder  
Excessive  
amount of  
solder  
Terminal  
Solder  
PCB  
Land  
Visually check that the Relay is properly soldered.  
Precautions  
Correct Use  
Handling  
Do not unpack the relay until mounting it.  
Environmental Conditions During Operation,  
Storage, and Transportation  
It is best to keep the relay in its packaging in a controlled environ-  
ment until it is ready for mounting.  
Soldering  
Solder: JIS Z3282, H63A or equivalent  
If the Relay is stored for a long time in an adverse environment with  
high temperature, high humidity, organic gases, or sulfide gases, sul-  
fide or oxide films will form on the contact surfaces. These films may  
result in unstable contact, contact problems, or functional problems.  
Therefore, operate, store, or transport the product under specified  
environmental conditions.  
Soldering temperature: Approx. 250°C (260°C if the DWS method is  
used)  
Soldering time: Approx. 5 s max. (approx. 2 s for the first time and  
approx. 3 s for the second time if the DWS method is used)  
Be sure to make a molten solder level adjustment so that the solder  
will not overflow on the PCB.  
Latching Relay Mounting  
Make sure that the vibration or shock that is generated from other  
devices, such as relays in operation, on the same panel and imposed  
on the Latching Relay does not exceed the rated value, otherwise the  
Latching Relay that has been set may be reset or vice versa. The  
Latching Relay is reset before shipping. If excessive vibration or  
shock is imposed, however, the Latching Relay may be set acciden-  
tally. Be sure to apply a reset signal before use.  
Claw Securing Force During Automatic  
Mounting  
During automatic insertion of Relays, make sure to set the securing  
force of each claw to the following so that the Relays characteristics  
will be maintained.  
Maximum Allowable Voltage  
The maximum allowable voltage of the coil can be obtained from the  
coil temperature increase and the heat-resisting temperature of coil  
insulating sheath material. (Exceeding the heat-resisting tempera-  
ture may result in burning or short-circuiting.) The maximum allow-  
able voltage also involves important restrictions which include the  
following:  
Direction A: 1.96 N  
Direction B: 4.90 N  
Direction C: 1.96 N  
60  
Low Signal Relay G6K  
Must not cause thermal changes in or deterioration of the insulating  
material.  
Must not cause damage to other control devices.  
Must not cause any harmful effect on people.  
Must not cause fire.  
Therefore, be sure to use the maximum allowable voltage as speci-  
fied in the catalog.  
As a rule, the rated voltage must be applied to the coil. A voltage  
exceeding the rated value, however, can be applied to the coil pro-  
vided that the voltage is less than or equal to the maximum allowable  
voltage. It must be noted that continuous voltage application to the  
coil will cause a coil temperature increase which may affect charac-  
teristics such as electrical life and coil insulation.  
Coating  
The Relay mounting on the PCB may be coated or washed but do not  
apply silicone coating or detergent containing silicone, otherwise the  
silicone coating or detergent may remain on the surface of the Relay.  
PCB Mounting  
If two or more Relays are closely mounted with the long sides of the  
Relays facing each other and soldering is performed with infrared  
radiation, the solder may not be properly exposed to the infrared  
rays. Be sure to keep the proper distance between adjacent Relays  
as shown below to insure formation of good solder joints.  
G6K-2G  
2 mm min.  
G6K-2F  
2.7 mm min.  
Two or more Relays may be mounted as closely as desired with the  
short sides of the Relays facing each other.  
Low Signal Relay G6K  
61  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
Low Signal Relay G6K  

相关型号:

G6K-2P-TR-DC6

Power/Signal Relay
OMRON

G6K-2P-TR-DC9

Power/Signal Relay
OMRON

G6K-2P-TR24VDC

Power/Signal Relay, DPDT, Momentary, 24VDC (Coil), 1A (Contact), 30VDC (Contact), AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-TR5VDC

Power/Signal Relay, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y

Surface Mounting Relay with the World’s Smallest Mounting Area and a Height of Only 5.2 mm
OMRON

G6K-2P-Y-4.5VDC

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-5VDC

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-DC24

Power/Signal Relay, DPDT, Momentary, 0.005A (Coil), 24VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-DC3

Power/Signal Relay, DPDT, Momentary, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-DC4.5

Power/Signal Relay, DPDT, Momentary, 0.023A (Coil), 4.5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-DC5

Power/Signal Relay, 2 Form C, DPDT, Momentary, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6K-2P-Y-DC9

Power/Signal Relay, DPDT, Momentary, 0.011A (Coil), 9VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON