G6KU-2F-RF-S5VDC-TR09 [OMRON]

RF Relay, DPDT, Latched, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT;
G6KU-2F-RF-S5VDC-TR09
型号: G6KU-2F-RF-S5VDC-TR09
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

RF Relay, DPDT, Latched, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 30VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT

光电二极管
文件: 总8页 (文件大小:238K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G6K(U)-2F-RF(-S)  
Surface-mounting High-frequency Relay  
Surface-mounting, 1-GHz-Band,  
Miniature, DPDT, High-frequency Relay  
Superior high-frequency characteristics (at  
1 GHz), such as an isolation of 20 dB min.  
between contacts of the same polarity or 30 dB  
min. between contacts of different polarity with an  
insertion loss of 0.2 dB max.  
Miniaturized to 10.3 × 6.9 × 5.4 mm (L × W × H).  
Rated power consumption of 100 mW with high  
sensitivity.  
Single-side stable and single-winding latching  
models available.  
Models with a smaller footprint (G6K(U)-2F-RF-S)  
are available to help save space.  
RoHS Compliant  
Ordering Information  
Model Number Legend:  
G6K@-@@-@-@  
1
2
3
4
5
1. Relay Function  
None: Single-side stable  
U: Single-winding latching  
2. Contact Form  
2: DPDT  
3. Terminal Shape  
5. Ground Terminal Shape  
F:  
Surface-mounting terminals  
None: Standard  
S: Small footprint  
4. Special Function  
RF:  
High-frequency compatible  
List of Models  
Standard Models with Surface-mounting Terminals  
Classification  
Structure  
Contact form  
Rated coil voltage  
Model  
Minimum quantity  
packaged (See note.)  
Single-side stable  
Plastic sealed DPDT  
3, 4.5, 5, 12, and 24 VDC G6K-2F-RF(-S)  
3, 4.5, 5, 12, and 24 VDC G6KU-2F-RF(-S)  
300 Units/tray  
Single-winding latching  
300 Units/reel  
Note: When ordering Relays in tape packing, add “-TR03” or “-TR09” to the end of the model number. If “-TR” is not added, the Relays  
will be provided in tray packing.  
Relays per reel: 300 for “-TR03”  
900 for “-TR09”  
This specification, however, is not part of the relay model number, so it is not marked on the relay case.  
Application Examples  
• Measurement equipment  
• Communications equipment  
• Broadcasting and audio-visual equipment  
• Medical equipment  
1
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Specifications  
Contact Ratings  
Coil Ratings  
Single-side Stable Models  
Load  
Resistive load  
G6K-2F-RF(-S)  
Rated load  
125 VAC, 0.3 A  
30 VDC, 1 A  
1 GHz, 1 W (See note.)  
Rated voltage (VDC)  
Rated current (mA)  
Coil resistance ()  
3
4.5  
5
12  
24  
33.0  
91  
23.2  
194  
21.1  
237  
9.1  
4.6  
Rated carry current  
1 A  
1,315  
5,220  
Max. switching voltage  
Max. switching current  
125 VAC or 60 VDC  
1 A  
Must operate voltage 80% max. of rated voltage  
(V)  
Must release voltage 10% min. of rated voltage  
(V)  
Note: This value is for a V.SWR of 1.2 max. at the load.  
Maximum voltage (V) 150% of rated voltage  
High-frequency Characteristics (See  
Power consumption Approx. 100 mW  
(mW)  
note 3.)  
Frequency  
1 GHz  
20 dB min.  
Single-winding Latching Models  
G6KU-2F-RF(-S)  
Item  
Isolation  
Between contacts  
of the same polarity  
Rated voltage (VDC)  
Rated current (mA)  
Coil resistance ()  
3
4.5  
5
12  
24  
33.0  
91  
23.2  
194  
21.1  
237  
9.1  
4.6  
Between contacts  
of different polarity  
30 dB min.  
1,315  
5,220  
Must operate voltage 75% max. of rated voltage  
(V)  
Insertion loss  
0.2 dB max.  
V.SWR  
1.2 max.  
Must release voltage 75% max. of rated voltage  
(V)  
Maximum carry power  
Maximum switching power  
3 W (See note 4.)  
1 W (See note 4.)  
Maximum voltage (V) 150% of rated voltage  
Power consumption Approx. 100 mW  
(mW)  
Note: 1. The impedance of the measurement system is 50 .  
2. The above values are initial values.  
Note: 1. The rated current and coil resistance are measured at  
a coil temperature of 23°C with a tolerance of 10%.  
3. Contact your OMRON representative if the Relay will  
be used in applications that require high repeatability  
with high-frequency characteristics in microload re-  
gions.  
2. The operating characteristics are measured at a coil  
temperature of 23°C.  
3. The maximum voltage is the highest voltage that can  
4. These values are for a V.SWR of 1.2 max. at the load.  
be imposed on the Relay coil instantaneously.  
Characteristics  
Item  
Single-side stable models  
G6K-2F-RF(-S)  
Single-winding latching models  
G6KU-2F-RF(-S)  
Contact resistance (See note 2.)  
Operating (set) time (See note 3.)  
Release (reset) time (See note 3.)  
Minimum set/reset pulse time  
Insulation resistance (See note 4.)  
100 mmax.  
3 ms max. (approx. 1.4 ms)  
3 ms max. (approx. 1.3 ms)  
---  
3 ms max. (approx. 1.2 ms)  
3 ms max. (approx. 1.2 ms)  
10 ms  
1,000 Mmin. (at 500 VDC)  
750 VAC, 50/60 Hz for 1 min  
Dielectric  
strength  
Between coil and contacts  
Between contacts of different po- 750 VAC, 50/60 Hz for 1 min  
larity  
Between contacts of the same po- 750 VAC, 50/60 Hz for 1 min  
larity  
Between ground and coil/contacts 500 VAC, 50/60 Hz for 1 min  
Vibration resistance  
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude) and  
2
55 to 500 to 55 Hz, 300 m/s  
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude) and  
2
55 to 500 to 55 Hz, 200 m/s  
2
Shock resistance  
Endurance  
Destruction: 1,000 m/s  
Malfunction: 750 m/s  
2
Mechanical: 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)  
Electrical:  
100,000 operations min. (at a switching frequency of 1,800 operations/hour)  
Ambient temperature  
Ambient humidity  
Weight  
Operating: 40°C to 70°C (with no icing or condensation)  
Operating: 5% to 85%  
Approx. 0.95 g  
Note:  
1. The above values are initial values.  
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
3. Values in parentheses are actual values.  
4. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielectric  
strength.  
2
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Engineering Data  
G6K-2F-RF  
Agile HP 8753D  
Vector Network  
Analyzer  
50  
terminaltion  
High-frequency Characteristics  
(Isolation)  
High-frequency Characteristics  
(Insertion Loss)  
High-frequency Characteristics  
(Return Loss, V.SWR)  
G6K-2F-RF  
G6K-2F-RF  
G6K-2F-RF  
Average value (initial)  
Average value (initial)  
Average value (initial)  
0
0
0
1.8 V  
Test subject: G6K-2F-RF  
Number of Units: 5  
Test subject: G6K-2F-RF  
Number of Units: 10  
Test subject: G6K-2F-RF  
Number of Units: 10  
·
S
10  
1.7  
W
10  
R
0.1  
20  
30  
40  
50  
60  
70  
1.6  
20  
30  
40  
50  
60  
1.5  
1.4  
1.3  
1.2  
0.2  
0.3  
Return loss  
V.SWR  
0.4  
0.5  
1.1  
1.0  
70  
80  
80  
90  
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
G6K-2F-RF-S  
G6K-2F-RF-S  
G6K-2F-RF-S  
Average value (initial)  
Average value (initial)  
Average value (initial)  
0
0
1.8  
1.7  
0
V
·
S
W
R
Test subject: G6K-2F-RF-S  
Number of Units: 10  
Test subject: G6K-2F-RF-S  
Number of Units: 5  
Test subject: G6K-2F-RF-S  
Number of Units: 10  
10  
20  
30  
40  
50  
60  
70  
10  
20  
30  
40  
50  
60  
0.1  
0.2  
0.3  
1.6  
1.5  
1.4  
1.3  
1.2  
Return loss  
V.SWR  
0.4  
0.5  
80  
90  
70  
80  
1.1  
1.0  
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
0
0.5  
1
1.5  
2
2.5  
3
Frequency (GHz)  
Frequency (GHz)  
Frequency (GHz)  
Note: 1. Refer to the G6K specifications for basic specifications not shown above.  
2. Ambient temperature condition: 23°C  
3. The high-frequency characteristics depend on the mounting board. Be sure to check operation including durability in actual  
equipment before use.  
3
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
G6K-2F-RF  
G6KU-2F-RF  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
Terminal Arrangement/Internal  
Connections (Top View)  
G6K-2F-RF  
7.6  
Orientation mark  
5.4  
3.2  
8
7
6
5
4
12.8  
10.3  
0.5  
0.6  
6.9  
7.8  
1.8  
+
7
2.5  
1
2
3
5.4  
0.3  
2.5  
0.8  
0.5  
1.35  
G6KU-2F-RF  
(1.35)  
Orientation mark  
3.2  
5.4  
1.95  
8
7
6
5
11.5  
7.6  
+  
S R  
+ −  
Note: 1. Each value has a tolerance of 0.3 mm.  
2. The coplanarity of the terminals is 0.15 mm max.  
1
2
3
4
G6K-2F-RF-S  
G6KU-2F-RF-S  
Terminal Arrangement/Internal  
Connections (Top View)  
Mounting Dimensions (Top View)  
Tolerance: 0.1 mm  
0.85  
1.55  
1.5  
0.85  
G6K-2F-RF-S  
8.8  
7.6  
5.4  
Orientation mark  
G6K-2F-RF-S  
VDC  
7.8 8.6  
3.2  
8
1
7
2
6
3
5
4
1.2  
1.6  
JAPAN  
+
10.7  
10.3  
2.1  
1.8  
7.5  
7
0.6  
6.9  
G6KU-2F-RF-S  
5.4  
(1.35)  
1
0.8  
0.3  
Orientation mark  
1.8  
0.5  
1.35  
8
7
6
5
3.2  
5.4  
+  
S R  
7.6  
+ −  
1
2
3
4
Note: 1. Each value has a tolerance of 0.3 mm.  
2. The coplanarity of the terminals is 0.15 mm max.  
4
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Tape Packing Specifications (Surface-mounting Terminal Relays)  
• Add “-TR03” or “-TR09” to the end of the model number to order  
Relays in tape packing. If “-TR” is not added, the Relays will be  
provided in tray packing.  
3. Carrier Tape Dimensions  
G6K(U)-2F-RF  
5.9 0.1  
12 1.0  
4
Relays per reel: 300 for “-TR03”  
1.5+0.1 dia.  
0.1  
900 for “-TR09”  
0
1.75 0.1  
11.5 0.1  
2
0.1  
0.4 0.1  
B
A
1. Direction of Relay Insertion  
24 0.2  
13.4 0.1  
10.9 0.1  
Top tape  
(cover tape)  
0°  
3°1°  
B-B Cross Section  
B
A
4.25 0.1  
0°  
3°1°  
Carrier tape  
Embossed  
tape  
Pulling Direction  
A-A Cross Section  
G6K(U)-2F-RF  
G6K(U)-2F-RF-S  
Orientation mark  
Orientation mark  
8.5 0.1  
G6K(U)-2F-RF-S  
Pulling  
direction  
Pulling  
direction  
5.9 0.1  
12 0.1  
4
0.1  
1.5+0.1 dia.  
1.75 0.1  
0
2
0.1  
0.4 0.05  
B
A
2. Reel Dimensions  
11.5 0.1  
24 0.3  
29.5  
1
11.3 0.1  
25.5 0.5  
13 0.2 dia.  
3° max.  
21 0.8 dia.  
2
0.5  
B-B Cross Section  
B
A
3° max.  
9.2 0.1  
A
330 80  
A-A Cross Section  
R1  
Enlarged View of Section A  
5
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Recommended Soldering Method  
The thickness of cream solder to be applied should be between  
200 and 250 µm and the land pattern should be based on  
OMRON’s recommended PCB pattern.  
Recommended Conditions for IRS Method  
(Surface-mounting Terminals)  
(1) IRS Method (Mounting Solder: Lead)  
To maintain the correct soldering joint shown in the following dia-  
gram, we recommend applying solder with the soldering condi-  
tions shown on the left.  
Correct Soldering  
Incorrect Soldering  
Relay  
Soldering  
220 to  
245  
Terminal  
Solder  
Excessive  
amount of  
solder  
Insufficient  
amount of  
solder  
PCB  
Land  
180 to  
200  
Check the soldering in the actual mounting conditions before use.  
Preheating  
150  
90 to 120  
20 to 30  
Time (s)  
Note: The temperature profile indicates the temperature on the  
circuit board surface.  
(2) IRS Method (Mounting Solder: Lead-free)  
Case top panel  
(peak): 255°C max.  
Soldering  
250 max.  
230  
180  
Preheating  
150  
Relay terminal  
section  
120 max.  
30 max.  
Time (s)  
Note: The temperature profile indicates the temperature on the  
PCB.  
6
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
Safety Precautions  
For general precautions, refer to the PCB Relays Catalog (X033).  
Familiarize yourself with the precautions and glossary before  
using the G6K(U)-2F-RF.  
Claw Securing Force During Automatic  
Mounting  
During automatic insertion of Relays, be sure to set the securing  
force of each claw to the following so that the Relay’s characteris-  
tics will be maintained.  
Precautions for Correct Use  
Relay Handling  
C
Direction A: 1.96 N max.  
Direction B: 4.90 N max.  
Direction C: 1.96 N max.  
Use the Relay as soon as possible after opening the moisture-  
proof package. If the Relay is left for a long time after opening the  
moisture-proof package, the appearance may suffer and seal fail-  
ure may occur after the solder mounting process. To store the  
Relay after opening the moisture-proof package, place it into the  
original package and seal the package with adhesive tape.  
B
Secure the claws to the shaded area.  
Do not attach them to the center of the  
Relay or just one part of the Relay.  
When washing the product after soldering the Relay to a PCB,  
use a water-based solvent or alcohol-based solvent and keep the  
solvent temperature to less than 40°C. Do not put the Relay in a  
cold cleaning bath immediately after soldering.  
Coating  
Do not use silicone coating to coat the Relay when it is mounted  
to the PCB. Do not wash the PCB after the Relay is mounted  
using detergent containing silicone. Otherwise, the detergent may  
remain on the surface of the Relay.  
Environmental Conditions for Usage, Storage,  
and Transport  
Avoid direct sunlight when using, storing, or transporting the  
Relay and maintain normal temperature, humidity, and pressure  
conditions.  
Repeatability  
Contact your OMRON representative if the Relay will be used in  
applications that require high repeatability with high-frequency  
characteristics in microload regions.  
Long-term, Continuous ON Contacts  
Using the Relay in a circuit where the Relay will be ON continu-  
ously for long periods (rather than switching) can lead to unstable  
contacts because the heat generated by the coil itself will affect  
the insulation and can cause a film to develop on the contact sur-  
faces. We recommend using a latching relay (magnetic-holding  
relay) in this kind of circuit. If a single-side stable model must be  
used in this kind of circuit, we recommend adding fail-safe circuits  
in case the contact fails or the coil burns out.  
7
G6K(U)-2F-RF(-S)  
G6K(U)-2F-RF(-S)  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
Cat. No. K908-E1-02  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON RELAY & DEVICES Corporation  
Low Signal Relay Division  
Marketing & Product Engineering Department  
1110, Sugi, Yamaga-city, Kumamoto-Pref., 861-0596 Japan  
Tel: (81)968-44-4194/Fax: (81)968-44-4107  
0707  

相关型号:

G6KU-2F-RF-SDC12

High Frequency Relay
OMRON

G6KU-2F-RF-SDC24

High Frequency Relay
OMRON

G6KU-2F-RF-SDC3

High Frequency Relay
OMRON

G6KU-2F-RF-SDC4.5

High Frequency Relay
OMRON

G6KU-2F-RF-SDC5

High Frequency Relay
OMRON

G6KU-2F-RF-SDC6

High Frequency Relay
OMRON

G6KU-2F-RF-SDC9

High Frequency Relay
OMRON

G6KU-2F-RF-T

Surface Mount, 1GHz / 3 GHz Miniature DPDT, High Frequency Relay
OMRON
OMRON
OMRON
OMRON