G6KU-2F-RF-T-TR09DC3 [OMRON]
RF Relay,;型号: | G6KU-2F-RF-T-TR09DC3 |
厂家: | OMRON ELECTRONICS LLC |
描述: | RF Relay, |
文件: | 总7页 (文件大小:856K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
Surface-mounting, 1-GHz-Band/
3-GHz-Band, Miniature, DPDT,
High-frequency Relay
• Superior high-frequency characteristics (at 1 GHz), such as an isolation of
20 dB min. between contacts of the same polarity or 30 dB min. between
contacts of different polarity with an insertion loss of 0.2 dB max.
• Miniaturized to 10.3 × 6.9 × 5.4 mm (L × W × H).
• Rated power consumption of 100 mW with high sensitivity
• Single-side stable and single-winding latching models available.
• Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.
• New G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.
RoHS Compliant
■Model Number Legend
G6K@-@@-@-@
■Application Examples
• Communications equipment
• Broadcasting and audio-visual equipment
• Test & measurement equipment
• Medical equipment
G
㧢
—
— —
—
—
1
2 3
4
5
K
U
1. Relay Function
4. Special Function
None: Single-side stable
U: Single-winding latching
RF: High-frequency compatible
2
F
R
F
5. Terminal Shape
None: Standard
2. Number of poles/
Contact Form
S: Small footprint
S
,
2: 2-pole/ DPDT (2c)
T: Compatible with 3 GHz
T
3. Terminal Shape
■Ordering Information
●Standard Models with Surface-mounting Terminals
Standard Specifications
Relay Function
Single-side stable
Enclosure rating
Fully sealed
Contact form
Model
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
G6K-2F-RF
G6KU-2F-RF
DPDT
(2c)
300 pcs/tray
300 or 900 pcs/reel
Single-winding latching
Board space-saving model
Relay Function
Single-side stable
Enclosure rating
Contact form
Model
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
G6K-2F-RF-S
G6KU-2F-RF-S
DPDT
(2c)
300 pcs/tray
300 or 900 pcs/reel
Fully sealed
Single-winding latching
Compatible with 3 GHz
Relay Function
Single-side stable
Enclosure rating
Fully sealed
Contact form
Model
Rated coil voltage
3, 4.5, 5, 12, 24 VDC
3, 4.5, 5, 12, 24 VDC
Minimum packing unit
G6K-2F-RF-T
G6KU-2F-RF-T
DPDT
(2c)
300 pcs/tray
300 or 900 pcs/reel
Single-winding latching
Note 1. Please add the coil rated voltage (V) to the model number when ordering.
Example: G6K-2F-RF DC3
In addition, the delivered product and its package will be marked with voltage specification as "@@ VDC".
Note 2. When ordering Relays in tape packing, add "-TR03" or "-TR09" to the end of the model number.
Example: G6K-2F-RF-TR03 DC3
Relays per reel: 300 pcs for -TR03
: 900 pcs for -TR09
This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If "-TR03" or "-TR09" is not added to the end of the
model number, the Relays will be provided in tray packing.)
1
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
■Ratings
●Coil: Single-side Stable (G6K-2F-RF(-S, -T))
Must operate voltage Must release voltage Maximum voltage
Power consumption
Item
Rated current
(mA)
Coil resistance
(V)
(V)
(V)
(Ω)
(mW)
Rated voltage
3 VDC
ꢀ of rated voltage
33.0
23.2
21.1
9.1
91
194
237
1,315
5,220
4.5 VDC
5 VDC
12 VDC
24 VDC
80ꢀ max.
10ꢀ min.
150ꢀ
Approx. 100
4.6
●Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T))
Must set voltage
(V)
Must reset voltage
(V)
ꢀ of rated voltage
Maximum voltage
(V)
Item
Rated current
(mA)
Coil resistance
Power consumption
(mW)
(Ω)
Rated voltage
3 VDC
33.0
23.2
21.1
9.1
91
194
237
1,315
5,220
4.5 VDC
5 VDC
12 VDC
24 VDC
75ꢀ max.
75ꢀ max.
150ꢀ
Approx. 100
4.6
Note 1. The rated current and coil resistance are measured at a coil temperature of 23•C with a tolerance of 10ꢀ.
Note 2. The operating characteristics are measured at a coil temperature of 23•C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
●Contacts
●High-frequency Characteristics *1
Item
Load
Resistive load
Model G6K(U)-2F-RF(-S, -T)
G6K
(
U
)
-2F-RF-T
125 VAC, 0.3 A
30 VDC, 1 A
1 GHz, 1 W *
Item
Frequency
1GHz
3GHz
G
㧢
Rated load
Between
contacts of
the same
polarity
Between
contacts of
different
polarity
K
U
20 dB min.
18 dB min.
25 dB min.
Rated carry current
Max. switching voltage
Max. switching current
1 A
125 VAC or 60 VDC
1A
Isolation
2
F
R
F
*
This value is for a V.SWR of 1.2 max. at the load.
30 dB min.
Insertion loss
V.SWR
Maximum carry power
0.2 dB max.
1.2 max.
3W *2
0.6 dB max.
1.4 max.
S
,
T
Maximum switching power
1W *2
Note 1. The impedance of the measurement system is 50 Ω.
Note 2. The above values are initial values.
*1.
Contact your OMRON representative if the Relay will be used in an
application that requires high repeatability in high-frequency
characteristics for the microload region. (Such applications include
testing and measurement equipment and ATE applications.)
These values are for a V.SWR of 1.2 max. at the load.
*2.
■Characteristics
Relay Function
Model
Single-side stable models
G6K-2F-RF(-S, -T)
Single-winding latching models
G6KU-2F-RF(-S, -T)
Item
Contact resistance *1
Operating (set) time *2
Release (reset) time *2
Minimum set/reset pulse time
Insulation resistance *3
Between coil and
contacts
100 mΩ max.
3 ms max. (approx. 1.4 ms)
3 ms max. (approx. 1.3 ms)
3 ms max. (approx. 1.2 ms)
3 ms max. (approx. 1.2 ms)
10 ms
---
1,000 MΩ min. (at 500 VDC)
750 VAC, 50/60 Hz for 1 min
Between contacts of
different polarity
Between contacts of the
same polarity
Between ground and
coil/contacts
750 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
500 VAC, 50/60 Hz for 1 min
Dielectric
strength
Destruction
Malfunction
Destruction
Malfunction
Mechanical
Electrical
10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s2
10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s2
1,000 m/s2
750 m/s2
50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
100,000 operations min. (at a switching frequency of 1,800 operations/hour)
-40•C to 70•C (with no icing or condensation)
5ꢀ to 85ꢀ
Vibration
resistance
Shock
resistance
Durability
Ambient operating temperature
Ambient operating humidity
Weight
Approx. 0.95 g
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. Values in parentheses are actual values.
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
2
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
■Engineering Data
G6K-2F-RF
Agile HP 8753D
Vector Network
Analyzer
50Ω
terminaltion
HP8753D
●High-frequency Characteristics
(Isolation) *1, *2
●High-frequency Characteristics
(Insertion Loss) *1, *2
●High-frequency Characteristics
(Return Loss, V.SWR) *1, *2
G6K-2F-RF
G6K-2F-RF
G6K-2F-RF
Average value (initial)
Average value (initial)
Average value (initial)
0
0
V
·
S
W
R
1.8
1.7
0
Test subject: G6K-2F-RF
Number of Relays: 10 pcs
Test subject: G6K-2F-RF
Test subject: G6K-2F-RF
Number of Relays: 10 pcs
Number of Relays: 5 pcs
10
10
0.1
20
30
40
50
60
70
1.6
1.5
1.4
1.3
1.2
20
30
0.2
0.3
40
50
60
Return loss
V.SWR
0.4
0.5
80
90
1.1
1.0
70
80
G
㧢
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
K
U
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-S
G6K-2F-RF-S
G6K-2F-RF-S
Average value (initial)
Average value (initial)
Average value (initial)
2
F
R
F
0
0
V
·
S
W
R
1.8
1.7
0
Test subject: G6K-2F-RF-S
Number of Relays: 10 pcs
Test subject: G6K-2F-RF-S
Number of Relays: 10 pcs
Test subject: G6K-2F-RF-S
Number of Relays: 5 pcs
10
20
30
40
50
60
70
10
20
30
40
50
60
0.1
0.2
0.3
1.6
1.5
1.4
1.3
1.2
S
,
T
Return loss
V.SWR
0.4
0.5
80
90
1.1
1.0
70
80
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
0
0.5
1
1.5
2
2.5
3
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
G6K-2F-RF-T
G6K-2F-RF-T
G6K-2F-RF-T
Average value (initial)
Average value (initial)
Average value (initial)
V
·
S
W
R
0
0.0
0
2.6
2.4
N.O.
N.C.
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
N.O.
N.C.
Test subject: G6K-2F-RF-T
Number of Relays: 5 pcs
10
20
30
40
50
60
70
10
20
30
40
50
60
0.2
0.4
0.6
2.2
2.0
1.8
1.6
1.4
Return loss
V.SWR
0.8
1.0
70
80
1.2
1.0
80
90
0
1
2
3
4
5
6
0
1
2
3
4
5
6
0
1
2
3
4
5
6
Frequency (GHz)
Frequency (GHz)
Frequency (GHz)
Note. Refer to the G6K specifications for basic specifications not shown above.
*1. Ambient temperature condition: 23•C
*2. The high-frequency characteristics depend on the mounting board.
Be sure to check operation including durability in actual equipment before use.
3
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
■Dimensions
(Unit: mm)
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
Standard Specifications
G6K-2F-RF
G6KU-2F-RF
G6K-2F-RF
7.6
Orientation mark
5.4
3.2
8
7
6
5
4
12.8
10.3
−
+
0.5
0.6
6.9
7.8
1.8
7
2.5
1
2
3
5.4
0.3
2.5
0.8
0.5
1.35
G6KU-2F-RF
(1.35)
Orientation mark
3.2
5.4
1.95
8
7
6
5
11.5
7.6
− +
S R
+ −
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
Note:Check carefully the coil polarity of the Relay.
Mounting Dimensions (Top View)
Terminal Arrangement/
Internal Connections
(Top View)
Board space-saving model
G6K-2F-RF-S
Tolerance: 0.1 mm
0.85
1.55
1.5
0.85
G6KU-2F-RF-S
G6K-2F-RF-S
Orientation mark
8.8
7.6
G
㧢
5.4
G6K-2F-RF-S
K
U
7.8 8.6
3.2
1.2
VDC
8
7
2
6
3
5
4
JAPAN
1.6
−
+
2
F
R
F
10.7
10.3
0.6
2.1
7.5
1.8
7
1
6.9
G6KU-2F-RF-S
Orientation mark
S
,
5.4
(1.35)
0.8
0.3
1
1.8
T
0.5
1.35
8
7
6
5
3.2
5.4
− +
S R
7.6
+ −
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
Note:Check carefully the coil polarity of the Relay.
Mounting Dimensions (Top View)
Tolerance: 0.1 mm
Terminal Arrangement/
Internal Connections
(Top View)
Compatible with 3 GHz
G6K-2F-RF-T
0.85
0.5
0.85
G6KU-2F-RF-T
G6K-2F-RF-T
7.6
Orientation mark
5.4
3.2
G6K-2F-RF-T
VDC
7.8
8.6
8
7
2
6
3
5
4
30Y1YH
1.1
JAPAN
4-1.15
4.8
1.35
G6K-2F-RF-T
VDC
12
−
+
2.2
2.2
1
10.7
10.3
7
10.8
1.1
6.9
4.8
G6KU-2F-RF-T
Orientation mark
0.6
5.4
2.2 2.2
(2.45)
0.3
1.35
14-0.8
8
7
6
5
− +
0.5
1.35
S R
3.2
5.4
7.6
+ −
1
2
3
4
Note 1. Each value has a tolerance of 0.3 mm.
Note 2. The coplanarity of the terminals is 0.15 mm max.
Note:Check carefully the coil polarity of the Relay.
4
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
■Tape Packing Specifications (Surface-mounting Terminal Relays)
• Add “×-TR03” or “-TR09” to the end of the model number to order Relays in tape packing.
If “-TR” is not added, the Relays will be provided in tray packing.
Relays per reel: -TR03 300 pcs
-TR09 900 pcs
Minimun ordering unit:-TR03 300 pcs
-TR09 900 pcs
1. Direction of Relay Insertion
Top tape
(cover tape)
Carrier tape
Embossed tape
Pulling Direction
G6K(U)-2F-RF
G6K(U)-2F-RF-S(-T)
Orientation mark
Orientation mark
Pulling
direction
Pulling
direction
G
㧢
K
U
2. Reel Dimensions
2
F
R
F
1
29.5
25.5
0.5
0.2 dia.
13
0.8 dia.
21
0.5
2
S
,
A
T
330 80
R1
Enlarged View of Section A
3. Carrier Tape Dimensions
G6K(U)-2F-RF
G6K(U)-2F-RF-S(-T)
0.1
5.9
0.1
5.9
1.0
12
0.1
0.1
12
4
0.1
1.5㧗0.1 dia.
4
1.5㧗0.1 dia.
0
0.1
0.1
1.75
11.5
0
0.1
0.1
0.1
0.1
1.75
11.5
2
0.4
0.1
2
0.05
0.4
B
B
A
A
0.2
24
0.3
24
0.1
13.4
0.1
11.3
0.1
10.9
ޓ
0°
3°
-1°
3° max.
B-B Cross Section
B
B-B Cross Section
B
A
A
0.1
4.25
0.1
3° max.
9.2
ޓ
3°−1°
0°
A-A Cross Section
A-A Cross Section
0.1
8.5
5
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
■G6K(U)-2F-RF(-S, -T) Recommended Soldering Method
●Recommended Conditions for IRS Method (Surface-mounting Terminals)
• The thickness of cream solder to be applied should be
(1) IRS Method (Mounting Solder: Lead)
between 200 and 250 μm and the land pattern should be
based on OMRON’s recommended PCB pattern.
• To maintain the correct soldering joint shown in the following
diagram, we recommend applying solder with the soldering
conditions shown on the left.
Soldering
220~
245
Correct Soldering
Incorrect Soldering
180~
200
Relay
Terminal
Land
PCB
Preheating
150
Heel fillet is
formed
Solder
Insufficient amount of solder
Excessive amount of solder
Check the soldering in the actual mounting conditions before use.
90㨪120
20㨪30
Time (s)
(The temperature profile indicates the temperature on the circuit board surface.)
(2) IRS Method (Mounting Solder: Lead-free)
Case top panel (peak):
255°C max.
G
㧢
Soldering
250 max.
230
K
U
180
2
F
R
F
Preheating
120 max.
150
Relay terminal
section
S
,
T
30 max.
Time (s)
(The temperature profile indicates the temperature on the PCB.)
■Safety Precautions
●For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product
Data Book.
Correct Use
●Relay Handling
●Claw Securing Force During Automatic Mounting
• During automatic insertion of Relays, be sure to set the
securing force of each claw to the following so that the Relay’s
characteristics will be maintained.
• Use the Relay as soon as possible after opening the
moistureproof package. If the Relay is left for a long time after
opening the moisture-proof package, the appearance may
suffer and seal failure may occur after the solder mounting
process. To store the Relay after opening the moisture-proof
package, place it into the original package and seal the
package with adhesive tape.
• When washing the product after soldering the Relay to a PCB,
use a water-based solvent or alcohol-based solvent and keep
the solvent temperature to less than 40•C. Do not put the
Relay in a cold cleaning bath immediately after soldering.
C
B
Direction A: 1.96 N max.
Direction B: 4.90 N max.
Direction C: 1.96 N max.
Secure the claws to the shaded area. Do not attach them to the center of
the Relay or just one part of the Relay.
●Environmental Conditions for Usage, Storage, and
Transport
• Avoid direct sunlight when using, storing, or transporting the
Relay and maintain normal temperature, humidity, and
pressure conditions.
●Coating
• Do not use silicone coating to coat the Relay when it is
mounted to the PCB. Do not wash the PCB after the Relay is
mounted using detergent containing silicone. Otherwise, the
detergent may remain on the surface of the Relay.
●Long-term, Continuous ON Contacts
●Repeatability
• Using the Relay in a circuit where the Relay will be ON
continuously for long periods (rather than switching) can lead
to unstable contacts because the heat generated by the coil
itself will affect the insulation and can cause a film to develop
on the contact surfaces. We recommend using a latching relay
(magnetic-holding relay) in this kind of circuit. If a single-side
stable model must be used in this kind of circuit, we
recommend adding fail-safe circuits in case the contact fails or
the coil burns out.
• Contact your OMRON representative if the Relay will be used
in an application that requires high repeatability in
high-frequency characteristics for the microload region. (Such
applications include testing and measurement equipment and
ATE applications.)
6
G6K(U)-2F-RF(-S, -T)
Surface-mounting High-frequency Relay
G
㧢
K
U
2
F
R
F
S
,
T
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K242-E1-02
0214(0207)(O)
7
相关型号:
G6KU-2F-RF-TR03DC3
RF Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6KU-2F-RF-TR09DC12
RF Relay, DPDT, Latched, 0.009A (Coil), 12VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6KU-2F-RF-TR09DC3
RF Relay, DPDT, Latched, 0.033A (Coil), 3VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON
G6KU-2F-RF-TR09DC5
RF Relay, DPDT, Latched, 0.021A (Coil), 5VDC (Coil), 100mW (Coil), 1A (Contact), 60VDC (Contact), 1000MHz, DC Input, AC/DC Output, Surface Mount-Straight, ROHS COMPLIANT
OMRON