H3BA-X8HA [OMRON]
Solid-state Timer;型号: | H3BA-X8HA |
厂家: | OMRON ELECTRONICS LLC |
描述: | Solid-state Timer |
文件: | 总16页 (文件大小:1490K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid-state Timer
H3BA-X
Please read and understand this catalog before purchasing the products.
Please consult your OMRON representative if you have any questions or
comments. Refer to Warranty and Application Considerations (page 15),
and Safety Precautions (page 11).
Solid-state Timer with Single Time Range
and Operating Mode
• Time range: H3BA-X8HA (0.05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h)
• Operating mode: ON-delay only
• Pin type: 8-pin only
Model Number Structure
■ Model Number Legend
H3BA-@8H@
1
2
1. Series
X: Single mode/range
2. Time range
A: 0.05 s to 12 h
B: 0.3 s to 30 h
C: 0.6 s to 60 h
Ordering Information
■ List of Models
Control output
Supply voltage
110 VAC (50/60 Hz)
8-pin models
H3BA-X8HA 110 VAC
Time-limit SPDT and Instantaneous SPDT
H3BA-X8HB 110 VAC
H3BA-X8HC 110 VAC
H3BA-X8HA 220 VAC
H3BA-X8HB 220 VAC
H3BA-X8HC 220 VAC
H3BA-X8HA 24 VDC
H3BA-X8HB 24 VDC
H3BA-X8HC 24 VDC
220 VAC (50/60 Hz)
24 VDC
■ Accessories (Order Separately)
Name/specifications
Models
Protective Cover
Track Mounting/
Front Connecting Socket
Y92A-48B
P2CF-08
8-pin
Back Connecting Socket
8-pin
P3G-08
Y92H-1
Y92H-2
Hold-down Clips (See note 2.)
For PL08 Socket
For PF085A Socket
Note: Hold-down Clips are sold in sets of two.
Solid-state Timer H3BA-X
1
Specifications
■ General
Item
H3BA-X8H
Operating mode
Pin type
A: ON-delay
8-pin
Input type
---
Output type
SPDT (time-limit) and SPDT (instantaneous)
Mounting method
Approved standards
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, CCC : GB/T 14048.5 *
Conforms to EN61812-1 (Pollution degree 2 / Overvoltage category ΙΙΙ)
EMC
(EMI)
EN61812-1
Radiated Emissions:
Emission AC Mains:
(EMS)
EN 55011 class A
EN 55011 class A
EN61812-1
ESD Immunity:
EN 61000-4-2:
6 kV contact discharge,
8 kV air discharge
Radiated Radio-Frequency
Electromagnetic Field Immunity:
EN 61000-4-3: 10 V/m (80 MHz to 1 GHz AM modulation)
3 V/m (1.4 GHz to 2 GHz AM modulation)
1 V/m (2 GHz to 2.7 GHz AM modulation)
10 V/m (900 MHz Pulse modulation)
Conducted disturbances:
Burst Immunity:
EN 61000-4-6: 10 V (0.15 MHz to 80 MHz)
EN 61000-4-4:
2 kV power line
2 kV I/O signal line
2 kV common mode
1 kV differential mode
Surge Immunity:
EN 61000-4-5:
Voltage dips:
Voltage interruptions:
EN 61000-4-11
EN 61000-4-11
* CCC certification requirements
Recommended fuse
0216005 (250 VAC, 5 A) manufactured by Littelfuse
Rated operating voltage Ue
Rated operating current Ie
AC-15: Ue: 250 VAC, Ie: 3 A
AC-13: Ue: 250 VAC, Ie: 5 A
DC-13: Ue: 30 VDC, Ie: 1.5 A
Rated insulation voltage
250 V
Rated impulse withstand voltage 4 kV (at 240 VAC)
(altitude: 2,000 m max.)
Conditional short-circuit current
1,000 A
■ Time Ranges
Time unit
Model
× 0.1 s
sec
× 10 s
min
× 10 m
hrs
Full scale setting
H3BA-X8HA
H3BA-X8HB
H3BA-X8HC
12
30
60
Set time 0.05 to 1.2
0.3 to 3
1.2 to 12
3 to 30
6 to 60
12 to 120
30 to 300
60 to 600
1.2 to 12
3 to 30
6 to 60
12 to 120
30 to 300
60 to 600
1.2 to 12
3 to 30
6 to 60
0.6 to 6
2
Solid-state Timer H3BA-X
■ Ratings
Item
H3BA-X8H
Rated supply voltage
(See notes 1 and 2)
110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC
Operating voltage range
(See note 3)
85% to 110% of rated supply voltage
Power reset
Minimum power-opening time: 0.1 s
110 VAC: Approx. 3.6 VA (1.6 W)
220 VAC: Approx. 7.8 VA (1.9 W)
24 VDC: Approx. 0.9 W
Power consumption
Control outputs
Contact:
5 A at 250 VAC, resistance load (cosφ = 1)
Note: 1. DC ripple rate: 20% max.
2. Models other than 24-VDC H3BA-X8H models cause an inrush current. Pay careful attention when attempting to turn on power to such
models with non-contact output from a device such as a sensor.
3. 90% or higher if the Timer is used continuously at a high ambient temperature.
■ Characteristics
Item
Accuracy of operating time
Setting error
H3BA-X8H
0.3% FS max. ( 0.3% 10 ms in a range of 1.2 s)
5% FS 0.05 s max.
Reset time
Min. power-opening time: 0.1 s max.
Min. pulse-input time:
50 ms
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
0.5% FS max. ( 0.5% 10 ms in a range of 1.2 s)
2% FS max. ( 2% 10 ms in a range of 1.2 s)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal
parts
2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit
1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-X8H)
Impulse withstand voltage
Noise immunity
1 kV (between power terminals)
2 kV (between current-carrying terminal and exposed non-current-carrying metal parts,
1.5 kV for 24-VDC models)
AC models: 1.5 kV (between power terminals), and 600 V (between input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
DC models: 480 V (between power terminals), and 600 V (between input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Static immunity
Malfunction: 4 kV
Destruction: 8 kV
Vibration resistance
Shock resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions
Destruction: 1,000 m/s2 (approx. 100G) each in three directions
Malfunction: 100 m/s2 (approx. 10G) each in three directions
Operating: –10°C to 55°C (with no icing)
Ambient temperature
Storage:
–25°C to 65°C (with no icing)
Ambient humidity
Life expectancy
Operating: 35% to 85%
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)
Case color
Light gray (Munsell 5Y7/1)
IEC: IP40 (panel surface)
Approx. 95 g
Enclosure ratings
Weight
Solid-state Timer H3BA-X
3
Nomenclature
H3BA-X8H
Power Indicator (Green):
Lit when Timer operates.
PW
UP
Output Indicator (Orange):
6
Lit when Timer outputs.
8
4
2
0
10
12
Scale Range Display
Windows
min
Time Unit Selector
Select a unit from ×0.1sec,
sec, × 10sec, min, × 10min,
and hrs.
H3BA
Time setting knob (set time)
Operation
■ Block Diagrams
H3BA-X8H
AC (DC) input
Oscillation
circuit
Power supply
circuit
Counting
circuit
Output circuit
Indicator
circuit
Power-ON Output-ON
indicator indicator
Instantaneous
output circuit
4
Solid-state Timer H3BA-X
■ Basic Setting
■ Using the Setting Ring
Setting of Selector
Setting a Specific Time
The selectors can be turned clockwise and counterclockwise to
select the desired time range.
The selector has a snap mechanism that secures the selector at a
given position. Set the selector at a position at which it is secured. Do
not set it midway between two securing positions or a malfunction
could result from improper setting.
Mount the Panel Cover on the Timer, set the desired time with the
time setting knob, and place Time Setting Ring A onto the time
setting knob so that the time setting notch of Time Setting Ring A is
in the center of the reset lock position of the Panel Cover.
Time setting
Reset lock position
notch
Selection of Time Range
The desired time unit (× 0.1 sec, sec, × 10 sec, min, × 10 min, or hrs)
is displayed in the window below the time setting knob. A time range
is selected with the time range selector at the lower left corner of the
front panel, and the selected time range appears (in the window at
the lower right part) within the plastic frame of the time setting knob.
Time setting ring A Panel cover
Time setting notch
Setting position
6
4
8
2
10
0
12
min
Operating mode
display window
Example: To set the time to 10 s.
Time unit selector
Limiting the Setting Range
Example: To set a range of 10 and 20 s.
Time unit display window
Mount the Panel Cover on the Timer, set the time setting knob to 10 s
(the lower limit of the setting range), and place Time Setting Ring C
onto the time setting knob so that the stopper of Time Setting Ring C
is on the right edge of the reset lock position of the Panel cover. Next,
set the time setting knob to 20 s (the upper limit of the setting range),
place Time Setting Ring B onto the time setting knob so that the
stopper of Time Setting Ring B is on the left edge of the reset lock
position of the Panel Cover.
Setting of Time
Use the time setting knob to set the desired time.
Stopper
Reset lock position
Time setting
ring B
Time setting
ring C
Panel cover
Range
Solid-state Timer H3BA-X
5
■ Timing Chart
Note: 1. The minimum power-opening time (“Rt”) is 0.1 s.
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.
H3BA-X8H
Operating mode
A: ON-delay
Timing chart
Rt
Rt
t - a
t
t
Power 2 and 7
Output relay (NC)
8 and 5
Output relay (NO)
8 and 6
and output indicator
Output relay (NC)
1 and 4
Output relay (NO)
1 and 3
Power indicator
Basic operation
Power
t
Output
6
Solid-state Timer H3BA-X
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3BA-X8H
15
78
63.7
6
13.6
48
0.7
PW
UP
4
2
44.8 × 44.8
39 dia.
48
1
12
8 pins
Dimensions with Set Ring
16.5
50
42 dia.
50
Time setting ring
Panel cover
Dimensions with Y92F-30 Flush Mounting Adapter
Panel Cutout
Panel
P3G Back Connecting Socket
(sold separately)
+0.6
0.5 R max.
45
−0
(N)
+0.6
−0
PW
UP
45
58
52
42
48
Note: The mounting panel thickness should be 1 to 5 mm.
Dimensions with Y92F-70 Flush Mounting Adapter
Panel Cutout
Panel
Adapter mounting hole Two, 4.5 dia.
R0.5 max.
65 to 66
52 to 53
45±
0.15
PW
88
UP
76±0.2
45±0.15
58
Solid-state Timer H3BA-X
7
Dimensions with Y92F-71 Flush Mounting Adapter
Panel Cutout
Panel
R0.5 max.
+0.5
−0
56
45
PW
UP
+0.5
68
58
55
−0
45±0.2
43±0.2
Note: The mounting panel thickness
+0.2
50
−0
should be 1 to 3.2 mm.
Track Mounting
Flush Mounting
15
86.4
H3BA-X8H
H3BA-X8H
101.3
*
99
P3G-08
Y92F-30
2.3*
P2CF-08
Note: These dimensions vary with the kind of DIN track (reference
value).
■ Accessories (Order Separately)
Track Mounting/Front Connecting Socket
P2CF-08
Terminal Arrangement/
Internal Connections
(Top View)
Eight,
3
4.5
7.8
M3.5 7.5 sems
Surface Mounting Holes
Two, 4.5 dia. or two, M4
70 max.
35.4
Two, 4.5 dia.
holes
40±0.2
4
50 max.
20.3 max.
Back Connecting Socket
Terminal Arrangement/
Internal Connections
(Bottom View)
P3G-08
27 dia.
45
17
45
4.9
8
Solid-state Timer H3BA-X
Mounting Track
PFP-100N, PFP-50N
PFP-100N2
16
7.3±0.15
35±0.3
4.5
4.5
27
29.2
1.5
35±0.3
24
27±0.15
1
15 25
25
25
25 15
15 25
25
25
25
*
1
10
10
10
10
L
L
L: Length
1 m PFP-100N
50 cm PFP-50N
1 m
PFP-100N2
End Plate
PFP-M
Protective Cover
Y92A-48B
10
6.2
The protective cover protects the front panel, particularly the time
setting section, against dust, dirt, and water. It also prevents the set
value from being altered due to accidental contact with the time
setting knob.
1.8
1
35.5 35.3
50
1.8
Note: 1. The Y92A-48B Protective Cover is made of a hard plastic
and therefore it must be removed to change the timer set
value.
11.5
1.3
4.8
M4 × 8
pan head
screw
10
2. The Protective Cover cannot be mounted if the Panel Cov-
er (sold separately) is used on the Timer.
Y92A-48B
Spacer
PFP-S
16
PW
UP
12
5
34.8
44.3
16.5
Solid-state Timer H3BA-X
9
Time Setting Ring/Panel Cover
Hold-down Clip
There are two types of Panel Covers (Y92P-48GL, Y92P-48GB), all
of which are available in two colors. Use the most suitable type of
Panel Cover with the design of the scaling plate according to the
application.
Y92H-1
For PL08 Socket
Y92H-2
For PF085A Socket
When setting a given time for the Timer, use of the Y92S-27 or
Y92S-28 Time Setting Ring facilitates the time setting operation and
minimizes possible setting errors by operators.
The Time Setting Ring and Panel Cover should be used as a pair.
Setting a specific time Time Setting Ring A (Y92S-27) and Panel
Cover (Y92P-48GL, -48GB)
Limiting the setting
range
Time Setting Ring B or C (Y92S-28), and
Panel Cover (Y92P-48GL, -48GB)
Y92S-27
Time Setting A
Y92S-28
Time Setting B
Y92S-28
Time Setting C
Y92P-48GL
Light Gray
Y92P-48GB
Black
Installation
■ Terminal Arrangement
H3BA-X8H (Contact Output)
Power supply
(+)(~)
Note: The delayed contacts of conventional timers
are shown as follows:
The instantaneous contacts of conventional
timers are shown as follows:
10
Solid-state Timer H3BA-X
Safety Precautions
Warning Indications
■ Precautions for Safe Use
Please observe the following precautions for safe use of this product.
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury or in
property damage.
CAUTION
Environmental Precautions
Supplementary comments on what to
do or avoid doing, to use the product
safely.
Store the Timer within specified ratings. If the Timer has been stored
at -10°C or lower, let it stand for 3 hours or longer at room
temperature before turning ON the power supply.
Precautions for
Safe Use
Use the Timer within the specified ratings for operating temperature
and humidity.
Supplementary comments on what to
do or avoid doing, to prevent failure to
operate, malfunction or undesirable
effect on product performance.
Precautions for
Correct Use
Do not operate the Timer in locations subject to sudden or extreme
changes in temperature, or locations where high humidity may result
in condensation.
Meaning of Product Safety Symbols
Do not use the Timer in locations subject to excessive dust, corrosive
gas, or direct sunlight.
Do not use the Timer in locations subject to vibration or shock.
Extended use in such locations may result in damage due to stress.
Used to warn of the risk of electric shock under
specific conditions.
Install the Timer well away from any sources of static electricity, such
as pipes transporting molding materials, powders, or liquids.
Used to warn of the risk of minor injury caused by
high temperatures
Usage Precautions
Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
Used for general mandatory action precautions
for which there is no specified symbol.
Pay careful attention to polarity to prevent wrong connections when
wiring terminals.
Internal elements may be destroyed if a voltage outside the rated
voltage is applied.
Use to indicate prohibition when there is a risk of
minor injury from electrical shock or other source
if the product is disassembled.
Maintain voltage fluctuations in the power supply within the specified
range.
The Timer uses a transformerless power supply. Do not touch the
input terminals while the supply voltage is being applied, otherwise
an electric shock may occur.
CAUTION
Minor electric shock may occasionally occur. Do not
disassemble the product or touch the interior of the Timer.
Minor burns may occasionally occur. Do not touch the
product while power is being supplied or immediately
after power is turned OFF.
Minor fires may occasionally occur. Tighten terminal
screws to a torque of 1.08 N·m so that they do not
become loose.
Minor electric shock may occasionally occur during
operation. Install the terminal cover.
Minor electric shock, fire, or malfunction may occasionally
occur.
Do not allow metal fragments, lead wire scraps, or chips
from processing during installation to fall inside the Timer.
Solid-state Timer H3BA-X
11
Others
■ Precautions for Correct Use
When conducting a dielectric test, impulse voltage test, or insulation
resistance test between the electric circuit and non-current-carrying
metal parts of the Timer mounted to a control panel, be sure to take
the following steps. These steps will prevent the internal circuitry of
the Timer from damage that may be caused if a machine on the
control panel has an improper dielectric strength or insulation
resistance.
Changing the Setting
Do not change the time unit, time range, or operation mode while the
Timer is in operation, otherwise the Timer may malfunction.
Connecting the Operating Power
Supply
The H3BA-X8H contains a capacitor-drop power circuit. Use a
sinusoidal power supply with a commercial frequency. Do not use
power supplies with a high frequency component (such as inverter
power supplies) for Timers with 110 or 220-VAC specifications. Using
these power supplies can damage internal circuits.
1. Separate the Timer from the circuitry of the control panel by
disconnecting the socket from the Timer or wires.
2. Short-circuit all terminals of the Timer.
If any device with no-contact output, such as a proximity sensor,
photoelectric sensor, or SSR, is directly connected to the Timer,
current leakage from the device may cause Timer malfunction. Be
sure to test the device with the Timer before using the device for
actual applications.
If voltages other than the rated voltage is applied, the internal
components may be damaged. The internal element (varistor) will be
damaged if a voltage of higher than 100 VAC is applied to the 24-
VDC line.
Before using the Timer to switch inductive loads, be sure to connect
a surge absorbing element to the Timer in order to prevent the Timer
from malfunction and damage. A diode is an example of a surge
absorbing element for DC circuits and a surge absorber is an
example of a surge absorbing element for AC circuits.
Connect the power supply voltage through a relay or switch in such a
way that the voltage reaches a fixed value immediately or the Timer
may not be reset or a timer error could result.
Do not leave the Timer in time-up condition for a month or longer in
places with high temperatures, otherwise the internal parts, such as
an electrolytic capacitor, of the Timer may be damaged. Use the
Timer with an appropriate relay so that the Timer will not be left in
time-up condition for a long time.
A DC power supply can be connected if its ripple factor is 20% or
less and the mean voltage is within the rated operating voltage range
of the Timer.
If the Timer is mounted in contact with a mounting surface, the
service life of internal parts may be shortened. Provide at least 10
mm between the Timer and the mounting surface to prolong the
service life of the Timer.
Operating Time Setting
When setting the operating time, do not turn the setting knob beyond
its scale range. For precise time setting, conduct operation tests by
adjusting the setting knob.
When the Timer is reset right after the Timer goes into time-up
condition, be sure to provide the Timer with an appropriate circuit
configuration considering the resetting time of the Timer so that a
sequential error will not result.
The accuracy of the operating time of the Analog Timer is indicated
by the percentage value on the basis of the full-scale time. The
absolute fluctuation value will not be improved by changing the time
setting. Therefore, when selecting the model, be sure that the
application will be able to use a time setting as close as the full-scale
time setting of the Timer.
The Timer uses the constant value read method. Be careful when
changing the set value because the output of the Timer will be ON
when the set value coincides with the count value.
Be sure that the casing of the Timer is free from organic solvents,
such as paint thinner and benzene, strong acid, and alkali solvents,
which will damage the casing.
Note: It is impossible to connect more than two Timers in parallel.
12
Solid-state Timer H3BA-X
When using the US08, be sure to use 10.5-dia. max. multi-conductor
cable or 3-dia. max. insulated stranded wire for wiring.
■ Mounting
When the Y92F-30, Y92F-70 or Y92F-71 Flush Mounting Adapter is
used, just insert the Timer into the square panel hole. If the panel
coating is too thick and the hooks do not click, spread open the
hooks appropriately to the left and right after inserting the Timer to
the hole.
Surface Mounting
There is no particular restriction on surface mounting directions, but
be sure that the Timer is securely mounted horizontally.
Spread open the hooks to the left and right.
Panel
P2CF Socket
When mounting the Timer vertically with the P2CF Socket, consider
the movable hooks and be sure that there is a 20-mm space on each
of the upper and lower parts of the Socket.
The illustration is an ex
ample with the Y92F-70.
Duct
Hook
Spread open the hooks to the left and right.
P2CF-08
■ Dismounting
Surface Mounting with P2CF
Panel
PL Socket
1. Secure the Socket to the panel surface with screws and insert the
F-shaped hook into the sockets.
2. Connect the Timer to the Socket and press the tip of each hook
Panel Mounting
by hand.
Loosen the screws of the Flush Mounting Adapter, spread open the
hooks, and remove the Mounting Adapter.
Panel Mounting
When the Y92F-30, Y92F-70, Y92F-71 Mounting Adapter is used,
press the hook inwards with the thumb and index finger of both
hands, and press the Timer towards the front side.
When the Y92F-30 Flush Mounting Adapter is used, insert the Timer
into the square hole from the front side of the panel and put on the
Flush Mounting Adapter from the rear side of the Timer. Press the
Flush Mounting Adapter so that the space between the Flush
Mounting Adapter and the panel is reduced as much as possible,
and secure the Flush Mounting Adapter with screws.
Panel
Screw
Y92F-30
Solid-state Timer H3BA-X
13
14
Solid-state Timer H3BA-X
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year
(or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the
product in the customer's application or use of the product.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
OMRON Corporation
Tokyo, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
© OMRON Corporation 2013 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
CSM_1_4_1018
Cat. No. L126-E1-01
0313 (O)
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明