H3BA-X8HA [OMRON]

Solid-state Timer;
H3BA-X8HA
型号: H3BA-X8HA
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Solid-state Timer

文件: 总16页 (文件大小:1490K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Solid-state Timer  
H3BA-X  
Please read and understand this catalog before purchasing the products.  
Please consult your OMRON representative if you have any questions or  
comments. Refer to Warranty and Application Considerations (page 15),  
and Safety Precautions (page 11).  
Solid-state Timer with Single Time Range  
and Operating Mode  
• Time range: H3BA-X8HA (0.05 s to 12 h),  
H3BA-X8HB (0.3 s to 30 h),  
H3BA-X8HC (0.6 s to 60 h)  
• Operating mode: ON-delay only  
• Pin type: 8-pin only  
Model Number Structure  
Model Number Legend  
H3BA-@8H@  
1
2
1. Series  
X: Single mode/range  
2. Time range  
A: 0.05 s to 12 h  
B: 0.3 s to 30 h  
C: 0.6 s to 60 h  
Ordering Information  
List of Models  
Control output  
Supply voltage  
110 VAC (50/60 Hz)  
8-pin models  
H3BA-X8HA 110 VAC  
Time-limit SPDT and Instantaneous SPDT  
H3BA-X8HB 110 VAC  
H3BA-X8HC 110 VAC  
H3BA-X8HA 220 VAC  
H3BA-X8HB 220 VAC  
H3BA-X8HC 220 VAC  
H3BA-X8HA 24 VDC  
H3BA-X8HB 24 VDC  
H3BA-X8HC 24 VDC  
220 VAC (50/60 Hz)  
24 VDC  
Accessories (Order Separately)  
Name/specifications  
Models  
Protective Cover  
Track Mounting/  
Front Connecting Socket  
Y92A-48B  
P2CF-08  
8-pin  
Back Connecting Socket  
8-pin  
P3G-08  
Y92H-1  
Y92H-2  
Hold-down Clips (See note 2.)  
For PL08 Socket  
For PF085A Socket  
Note: Hold-down Clips are sold in sets of two.  
Solid-state Timer H3BA-X  
1
Specifications  
General  
Item  
H3BA-X8H  
Operating mode  
Pin type  
A: ON-delay  
8-pin  
Input type  
---  
Output type  
SPDT (time-limit) and SPDT (instantaneous)  
Mounting method  
Approved standards  
DIN track mounting, surface mounting, and flush mounting  
UL508, CSA C22.2 No.14, CCC : GB/T 14048.5 *  
Conforms to EN61812-1 (Pollution degree 2 / Overvoltage category ΙΙΙ)  
EMC  
(EMI)  
EN61812-1  
Radiated Emissions:  
Emission AC Mains:  
(EMS)  
EN 55011 class A  
EN 55011 class A  
EN61812-1  
ESD Immunity:  
EN 61000-4-2:  
6 kV contact discharge,  
8 kV air discharge  
Radiated Radio-Frequency  
Electromagnetic Field Immunity:  
EN 61000-4-3: 10 V/m (80 MHz to 1 GHz AM modulation)  
3 V/m (1.4 GHz to 2 GHz AM modulation)  
1 V/m (2 GHz to 2.7 GHz AM modulation)  
10 V/m (900 MHz Pulse modulation)  
Conducted disturbances:  
Burst Immunity:  
EN 61000-4-6: 10 V (0.15 MHz to 80 MHz)  
EN 61000-4-4:  
2 kV power line  
2 kV I/O signal line  
2 kV common mode  
1 kV differential mode  
Surge Immunity:  
EN 61000-4-5:  
Voltage dips:  
Voltage interruptions:  
EN 61000-4-11  
EN 61000-4-11  
* CCC certification requirements  
Recommended fuse  
0216005 (250 VAC, 5 A) manufactured by Littelfuse  
Rated operating voltage Ue  
Rated operating current Ie  
AC-15: Ue: 250 VAC, Ie: 3 A  
AC-13: Ue: 250 VAC, Ie: 5 A  
DC-13: Ue: 30 VDC, Ie: 1.5 A  
Rated insulation voltage  
250 V  
Rated impulse withstand voltage 4 kV (at 240 VAC)  
(altitude: 2,000 m max.)  
Conditional short-circuit current  
1,000 A  
Time Ranges  
Time unit  
Model  
× 0.1 s  
sec  
× 10 s  
min  
× 10 m  
hrs  
Full scale setting  
H3BA-X8HA  
H3BA-X8HB  
H3BA-X8HC  
12  
30  
60  
Set time 0.05 to 1.2  
0.3 to 3  
1.2 to 12  
3 to 30  
6 to 60  
12 to 120  
30 to 300  
60 to 600  
1.2 to 12  
3 to 30  
6 to 60  
12 to 120  
30 to 300  
60 to 600  
1.2 to 12  
3 to 30  
6 to 60  
0.6 to 6  
2
Solid-state Timer H3BA-X  
Ratings  
Item  
H3BA-X8H  
Rated supply voltage  
(See notes 1 and 2)  
110 VAC (50/60 Hz), 220 VAC (50/60 Hz), 24 VDC  
Operating voltage range  
(See note 3)  
85% to 110% of rated supply voltage  
Power reset  
Minimum power-opening time: 0.1 s  
110 VAC: Approx. 3.6 VA (1.6 W)  
220 VAC: Approx. 7.8 VA (1.9 W)  
24 VDC: Approx. 0.9 W  
Power consumption  
Control outputs  
Contact:  
5 A at 250 VAC, resistance load (cosφ = 1)  
Note: 1. DC ripple rate: 20% max.  
2. Models other than 24-VDC H3BA-X8H models cause an inrush current. Pay careful attention when attempting to turn on power to such  
models with non-contact output from a device such as a sensor.  
3. 90% or higher if the Timer is used continuously at a high ambient temperature.  
Characteristics  
Item  
Accuracy of operating time  
Setting error  
H3BA-X8H  
0.3% FS max. ( 0.3% 10 ms in a range of 1.2 s)  
5% FS 0.05 s max.  
Reset time  
Min. power-opening time: 0.1 s max.  
Min. pulse-input time:  
50 ms  
Influence of voltage  
Influence of temperature  
Insulation resistance  
Dielectric strength  
0.5% FS max. ( 0.5% 10 ms in a range of 1.2 s)  
2% FS max. ( 2% 10 ms in a range of 1.2 s)  
100 MΩ min. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and exposed non-current-carrying metal  
parts  
2,000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit  
1,000 VAC, 50/60 Hz for 1 min between contacts not located next to each other (750 VAC for H3BA-X8H)  
Impulse withstand voltage  
Noise immunity  
1 kV (between power terminals)  
2 kV (between current-carrying terminal and exposed non-current-carrying metal parts,  
1.5 kV for 24-VDC models)  
AC models: 1.5 kV (between power terminals), and 600 V (between input terminals),  
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)  
DC models: 480 V (between power terminals), and 600 V (between input terminals),  
square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)  
Static immunity  
Malfunction: 4 kV  
Destruction: 8 kV  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions  
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in three directions  
Destruction: 1,000 m/s2 (approx. 100G) each in three directions  
Malfunction: 100 m/s2 (approx. 10G) each in three directions  
Operating: –10°C to 55°C (with no icing)  
Ambient temperature  
Storage:  
–25°C to 65°C (with no icing)  
Ambient humidity  
Life expectancy  
Operating: 35% to 85%  
Mechanical: 10 million operations min. (under no load at 1,800 operations/h)  
Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h)  
Case color  
Light gray (Munsell 5Y7/1)  
IEC: IP40 (panel surface)  
Approx. 95 g  
Enclosure ratings  
Weight  
Solid-state Timer H3BA-X  
3
Nomenclature  
H3BA-X8H  
Power Indicator (Green):  
Lit when Timer operates.  
PW  
UP  
Output Indicator (Orange):  
6
Lit when Timer outputs.  
8
4
2
0
10  
12  
Scale Range Display  
Windows  
min  
Time Unit Selector  
Select a unit from ×0.1sec,  
sec, × 10sec, min, × 10min,  
and hrs.  
H3BA  
Time setting knob (set time)  
Operation  
Block Diagrams  
H3BA-X8H  
AC (DC) input  
Oscillation  
circuit  
Power supply  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Power-ON Output-ON  
indicator indicator  
Instantaneous  
output circuit  
4
Solid-state Timer H3BA-X  
Basic Setting  
Using the Setting Ring  
Setting of Selector  
Setting a Specific Time  
The selectors can be turned clockwise and counterclockwise to  
select the desired time range.  
The selector has a snap mechanism that secures the selector at a  
given position. Set the selector at a position at which it is secured. Do  
not set it midway between two securing positions or a malfunction  
could result from improper setting.  
Mount the Panel Cover on the Timer, set the desired time with the  
time setting knob, and place Time Setting Ring A onto the time  
setting knob so that the time setting notch of Time Setting Ring A is  
in the center of the reset lock position of the Panel Cover.  
Time setting  
Reset lock position  
notch  
Selection of Time Range  
The desired time unit (× 0.1 sec, sec, × 10 sec, min, × 10 min, or hrs)  
is displayed in the window below the time setting knob. A time range  
is selected with the time range selector at the lower left corner of the  
front panel, and the selected time range appears (in the window at  
the lower right part) within the plastic frame of the time setting knob.  
Time setting ring A Panel cover  
Time setting notch  
Setting position  
6
4
8
2
10  
0
12  
min  
Operating mode  
display window  
Example: To set the time to 10 s.  
Time unit selector  
Limiting the Setting Range  
Example: To set a range of 10 and 20 s.  
Time unit display window  
Mount the Panel Cover on the Timer, set the time setting knob to 10 s  
(the lower limit of the setting range), and place Time Setting Ring C  
onto the time setting knob so that the stopper of Time Setting Ring C  
is on the right edge of the reset lock position of the Panel cover. Next,  
set the time setting knob to 20 s (the upper limit of the setting range),  
place Time Setting Ring B onto the time setting knob so that the  
stopper of Time Setting Ring B is on the left edge of the reset lock  
position of the Panel Cover.  
Setting of Time  
Use the time setting knob to set the desired time.  
Stopper  
Reset lock position  
Time setting  
ring B  
Time setting  
ring C  
Panel cover  
Range  
Solid-state Timer H3BA-X  
5
Timing Chart  
Note: 1. The minimum power-opening time (“Rt”) is 0.1 s.  
2. The letter “t” in the timing charts stands for the set time and “t–a” means that the period is less than the time set.  
H3BA-X8H  
Operating mode  
A: ON-delay  
Timing chart  
Rt  
Rt  
t - a  
t
t
Power 2 and 7  
Output relay (NC)  
8 and 5  
Output relay (NO)  
8 and 6  
and output indicator  
Output relay (NC)  
1 and 4  
Output relay (NO)  
1 and 3  
Power indicator  
Basic operation  
Power  
t
Output  
6
Solid-state Timer H3BA-X  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
H3BA-X8H  
15  
78  
63.7  
6
13.6  
48  
0.7  
PW  
UP  
4
2
44.8 × 44.8  
39 dia.  
48  
1
12  
8 pins  
Dimensions with Set Ring  
16.5  
50  
42 dia.  
50  
Time setting ring  
Panel cover  
Dimensions with Y92F-30 Flush Mounting Adapter  
Panel Cutout  
Panel  
P3G Back Connecting Socket  
(sold separately)  
+0.6  
0.5 R max.  
45  
0  
(N)  
+0.6  
0  
PW  
UP  
45  
58  
52  
42  
48  
Note: The mounting panel thickness should be 1 to 5 mm.  
Dimensions with Y92F-70 Flush Mounting Adapter  
Panel Cutout  
Panel  
Adapter mounting hole Two, 4.5 dia.  
R0.5 max.  
65 to 66  
52 to 53  
45±  
0.15  
PW  
88  
UP  
76±0.2  
45±0.15  
58  
Solid-state Timer H3BA-X  
7
Dimensions with Y92F-71 Flush Mounting Adapter  
Panel Cutout  
Panel  
R0.5 max.  
+0.5  
0  
56  
45  
PW  
UP  
+0.5  
68  
58  
55  
0  
45±0.2  
43±0.2  
Note: The mounting panel thickness  
+0.2  
50  
0  
should be 1 to 3.2 mm.  
Track Mounting  
Flush Mounting  
15  
86.4  
H3BA-X8H  
H3BA-X8H  
101.3  
*
99  
P3G-08  
Y92F-30  
2.3*  
P2CF-08  
Note: These dimensions vary with the kind of DIN track (reference  
value).  
Accessories (Order Separately)  
Track Mounting/Front Connecting Socket  
P2CF-08  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Eight,  
3
4.5  
7.8  
M3.5 7.5 sems  
Surface Mounting Holes  
Two, 4.5 dia. or two, M4  
70 max.  
35.4  
Two, 4.5 dia.  
holes  
40±0.2  
4
50 max.  
20.3 max.  
Back Connecting Socket  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
P3G-08  
27 dia.  
45  
17  
45  
4.9  
8
Solid-state Timer H3BA-X  
Mounting Track  
PFP-100N, PFP-50N  
PFP-100N2  
16  
7.3±0.15  
35±0.3  
4.5  
4.5  
27  
29.2  
1.5  
35±0.3  
24  
27±0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
*
1
10  
10  
10  
10  
L
L
L: Length  
1 m PFP-100N  
50 cm PFP-50N  
1 m  
PFP-100N2  
End Plate  
PFP-M  
Protective Cover  
Y92A-48B  
10  
6.2  
The protective cover protects the front panel, particularly the time  
setting section, against dust, dirt, and water. It also prevents the set  
value from being altered due to accidental contact with the time  
setting knob.  
1.8  
1
35.5 35.3  
50  
1.8  
Note: 1. The Y92A-48B Protective Cover is made of a hard plastic  
and therefore it must be removed to change the timer set  
value.  
11.5  
1.3  
4.8  
M4 × 8  
pan head  
screw  
10  
2. The Protective Cover cannot be mounted if the Panel Cov-  
er (sold separately) is used on the Timer.  
Y92A-48B  
Spacer  
PFP-S  
16  
PW  
UP  
12  
5
34.8  
44.3  
16.5  
Solid-state Timer H3BA-X  
9
Time Setting Ring/Panel Cover  
Hold-down Clip  
There are two types of Panel Covers (Y92P-48GL, Y92P-48GB), all  
of which are available in two colors. Use the most suitable type of  
Panel Cover with the design of the scaling plate according to the  
application.  
Y92H-1  
For PL08 Socket  
Y92H-2  
For PF085A Socket  
When setting a given time for the Timer, use of the Y92S-27 or  
Y92S-28 Time Setting Ring facilitates the time setting operation and  
minimizes possible setting errors by operators.  
The Time Setting Ring and Panel Cover should be used as a pair.  
Setting a specific time Time Setting Ring A (Y92S-27) and Panel  
Cover (Y92P-48GL, -48GB)  
Limiting the setting  
range  
Time Setting Ring B or C (Y92S-28), and  
Panel Cover (Y92P-48GL, -48GB)  
Y92S-27  
Time Setting A  
Y92S-28  
Time Setting B  
Y92S-28  
Time Setting C  
Y92P-48GL  
Light Gray  
Y92P-48GB  
Black  
Installation  
Terminal Arrangement  
H3BA-X8H (Contact Output)  
Power supply  
(+)(~)  
Note: The delayed contacts of conventional timers  
are shown as follows:  
The instantaneous contacts of conventional  
timers are shown as follows:  
10  
Solid-state Timer H3BA-X  
Safety Precautions  
Warning Indications  
Precautions for Safe Use  
Please observe the following precautions for safe use of this product.  
Indicates a potentially hazardous  
situation which, if not avoided, may  
result in minor or moderate injury or in  
property damage.  
CAUTION  
Environmental Precautions  
Supplementary comments on what to  
do or avoid doing, to use the product  
safely.  
Store the Timer within specified ratings. If the Timer has been stored  
at -10°C or lower, let it stand for 3 hours or longer at room  
temperature before turning ON the power supply.  
Precautions for  
Safe Use  
Use the Timer within the specified ratings for operating temperature  
and humidity.  
Supplementary comments on what to  
do or avoid doing, to prevent failure to  
operate, malfunction or undesirable  
effect on product performance.  
Precautions for  
Correct Use  
Do not operate the Timer in locations subject to sudden or extreme  
changes in temperature, or locations where high humidity may result  
in condensation.  
Meaning of Product Safety Symbols  
Do not use the Timer in locations subject to excessive dust, corrosive  
gas, or direct sunlight.  
Do not use the Timer in locations subject to vibration or shock.  
Extended use in such locations may result in damage due to stress.  
Used to warn of the risk of electric shock under  
specific conditions.  
Install the Timer well away from any sources of static electricity, such  
as pipes transporting molding materials, powders, or liquids.  
Used to warn of the risk of minor injury caused by  
high temperatures  
Usage Precautions  
Install a switch or circuit breaker that allows the operator to  
immediately turn OFF the power, and label it to clearly indicate its  
function.  
Used for general mandatory action precautions  
for which there is no specified symbol.  
Pay careful attention to polarity to prevent wrong connections when  
wiring terminals.  
Internal elements may be destroyed if a voltage outside the rated  
voltage is applied.  
Use to indicate prohibition when there is a risk of  
minor injury from electrical shock or other source  
if the product is disassembled.  
Maintain voltage fluctuations in the power supply within the specified  
range.  
The Timer uses a transformerless power supply. Do not touch the  
input terminals while the supply voltage is being applied, otherwise  
an electric shock may occur.  
CAUTION  
Minor electric shock may occasionally occur. Do not  
disassemble the product or touch the interior of the Timer.  
Minor burns may occasionally occur. Do not touch the  
product while power is being supplied or immediately  
after power is turned OFF.  
Minor fires may occasionally occur. Tighten terminal  
screws to a torque of 1.08 N·m so that they do not  
become loose.  
Minor electric shock may occasionally occur during  
operation. Install the terminal cover.  
Minor electric shock, fire, or malfunction may occasionally  
occur.  
Do not allow metal fragments, lead wire scraps, or chips  
from processing during installation to fall inside the Timer.  
Solid-state Timer H3BA-X  
11  
Others  
Precautions for Correct Use  
When conducting a dielectric test, impulse voltage test, or insulation  
resistance test between the electric circuit and non-current-carrying  
metal parts of the Timer mounted to a control panel, be sure to take  
the following steps. These steps will prevent the internal circuitry of  
the Timer from damage that may be caused if a machine on the  
control panel has an improper dielectric strength or insulation  
resistance.  
Changing the Setting  
Do not change the time unit, time range, or operation mode while the  
Timer is in operation, otherwise the Timer may malfunction.  
Connecting the Operating Power  
Supply  
The H3BA-X8H contains a capacitor-drop power circuit. Use a  
sinusoidal power supply with a commercial frequency. Do not use  
power supplies with a high frequency component (such as inverter  
power supplies) for Timers with 110 or 220-VAC specifications. Using  
these power supplies can damage internal circuits.  
1. Separate the Timer from the circuitry of the control panel by  
disconnecting the socket from the Timer or wires.  
2. Short-circuit all terminals of the Timer.  
If any device with no-contact output, such as a proximity sensor,  
photoelectric sensor, or SSR, is directly connected to the Timer,  
current leakage from the device may cause Timer malfunction. Be  
sure to test the device with the Timer before using the device for  
actual applications.  
If voltages other than the rated voltage is applied, the internal  
components may be damaged. The internal element (varistor) will be  
damaged if a voltage of higher than 100 VAC is applied to the 24-  
VDC line.  
Before using the Timer to switch inductive loads, be sure to connect  
a surge absorbing element to the Timer in order to prevent the Timer  
from malfunction and damage. A diode is an example of a surge  
absorbing element for DC circuits and a surge absorber is an  
example of a surge absorbing element for AC circuits.  
Connect the power supply voltage through a relay or switch in such a  
way that the voltage reaches a fixed value immediately or the Timer  
may not be reset or a timer error could result.  
Do not leave the Timer in time-up condition for a month or longer in  
places with high temperatures, otherwise the internal parts, such as  
an electrolytic capacitor, of the Timer may be damaged. Use the  
Timer with an appropriate relay so that the Timer will not be left in  
time-up condition for a long time.  
A DC power supply can be connected if its ripple factor is 20% or  
less and the mean voltage is within the rated operating voltage range  
of the Timer.  
If the Timer is mounted in contact with a mounting surface, the  
service life of internal parts may be shortened. Provide at least 10  
mm between the Timer and the mounting surface to prolong the  
service life of the Timer.  
Operating Time Setting  
When setting the operating time, do not turn the setting knob beyond  
its scale range. For precise time setting, conduct operation tests by  
adjusting the setting knob.  
When the Timer is reset right after the Timer goes into time-up  
condition, be sure to provide the Timer with an appropriate circuit  
configuration considering the resetting time of the Timer so that a  
sequential error will not result.  
The accuracy of the operating time of the Analog Timer is indicated  
by the percentage value on the basis of the full-scale time. The  
absolute fluctuation value will not be improved by changing the time  
setting. Therefore, when selecting the model, be sure that the  
application will be able to use a time setting as close as the full-scale  
time setting of the Timer.  
The Timer uses the constant value read method. Be careful when  
changing the set value because the output of the Timer will be ON  
when the set value coincides with the count value.  
Be sure that the casing of the Timer is free from organic solvents,  
such as paint thinner and benzene, strong acid, and alkali solvents,  
which will damage the casing.  
Note: It is impossible to connect more than two Timers in parallel.  
12  
Solid-state Timer H3BA-X  
When using the US08, be sure to use 10.5-dia. max. multi-conductor  
cable or 3-dia. max. insulated stranded wire for wiring.  
Mounting  
When the Y92F-30, Y92F-70 or Y92F-71 Flush Mounting Adapter is  
used, just insert the Timer into the square panel hole. If the panel  
coating is too thick and the hooks do not click, spread open the  
hooks appropriately to the left and right after inserting the Timer to  
the hole.  
Surface Mounting  
There is no particular restriction on surface mounting directions, but  
be sure that the Timer is securely mounted horizontally.  
Spread open the hooks to the left and right.  
Panel  
P2CF Socket  
When mounting the Timer vertically with the P2CF Socket, consider  
the movable hooks and be sure that there is a 20-mm space on each  
of the upper and lower parts of the Socket.  
The illustration is an ex  
ample with the Y92F-70.  
Duct  
Hook  
Spread open the hooks to the left and right.  
P2CF-08  
Dismounting  
Surface Mounting with P2CF  
Panel  
PL Socket  
1. Secure the Socket to the panel surface with screws and insert the  
F-shaped hook into the sockets.  
2. Connect the Timer to the Socket and press the tip of each hook  
Panel Mounting  
by hand.  
Loosen the screws of the Flush Mounting Adapter, spread open the  
hooks, and remove the Mounting Adapter.  
Panel Mounting  
When the Y92F-30, Y92F-70, Y92F-71 Mounting Adapter is used,  
press the hook inwards with the thumb and index finger of both  
hands, and press the Timer towards the front side.  
When the Y92F-30 Flush Mounting Adapter is used, insert the Timer  
into the square hole from the front side of the panel and put on the  
Flush Mounting Adapter from the rear side of the Timer. Press the  
Flush Mounting Adapter so that the space between the Flush  
Mounting Adapter and the panel is reduced as much as possible,  
and secure the Flush Mounting Adapter with screws.  
Panel  
Screw  
Y92F-30  
Solid-state Timer H3BA-X  
13  
14  
Solid-state Timer H3BA-X  
Read and Understand this Catalog  
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have  
any questions or comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year  
(or other period if specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,  
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER  
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET  
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS  
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON  
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE  
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,  
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE  
MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the  
product in the customer's application or use of the product.  
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will  
be used.  
Know and observe all prohibitions of use applicable to this product.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON  
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR  
SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with  
your OMRON representative at any time to confirm actual specifications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a  
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application  
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.  
OMRON Corporation  
Tokyo, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69-2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
IL 60173-5302 U.S.A.  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2013 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  
CSM_1_4_1018  
Cat. No. L126-E1-01  
0313 (O)  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY