H3CR-FN48-125DC [OMRON]
Solid-state Twin Timers; 固态双定时器型号: | H3CR-FN48-125DC |
厂家: | OMRON ELECTRONICS LLC |
描述: | Solid-state Twin Timers |
文件: | 总23页 (文件大小:521K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HSoli3d-sCtateRTwi-nFTimers
DIN 48 × 48-mm Twin Timers
• Wide power supply ranges of 100 to 240 VAC and 48 to
125 VDC respectively.
• ON- and OFF-times can be set independently and so
combinations of long ON- or OFF-time and short OFF- or ON-
time settings are possible.
• Fourteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h
depending on the model to be used.
• Models with a flicker ON start or flicker OFF start are available.
• Easy sequence checks through instantaneous outputs for a
zero set value at any time range.
• Length, when panel-mounted with a Socket, of 80 mm or less.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
H3CR - F @ @ - @ @
1
2
3
4
5
1. Classification
F: Twin timers
2. Configuration
None: 11-pin socket
8: 8-pin socket
3. Twin Timer Mode
5. Supply Voltage
100-240AC: 100 to 240 VAC
24AC/DC: 24 VAC/VDC
None: Flicker OFF start
N:
Flicker ON start
12DC:
12 VDC
4. Time Range
None: 0.05 s to 30 h models
300: 1.2 s to 300 h models
48-125DC: 48 to 125 VDC
Ordering Information
■ List of Models
Operating
modes
Supply
voltage
0.05 s to 30 h models
1.2 s to 300 h models
11-pin models
8-pin models
H3CR-F8 100-240AC
H3CR-F8 24AC/DC
H3CR-F8 12DC
11-pin models
H3CR-F-300 100-240AC
H3CR-F-300 24AC/DC
H3CR-F-300 12DC
8-pin models
H3CR-F8-300 100-240AC
H3CR-F8-300 24AC/DC
H3CR-F8-300 12DC
Flicker OFF
start
100 to 240 VAC
24 VAC/DC
12 VDC
H3CR-F 100-240AC
H3CR-F 24AC/DC
H3CR-F 12DC
48 to 125 VDC
H3CR-F 48-125DC
H3CR-FN 100-240AC
H3CR-FN 24AC/DC
H3CR-FN 12DC
H3CR-F8 48-125DC
H3CR-F8N 100-240AC
H3CR-F8N 24AC/DC
H3CR-F8N 12DC
H3CR-F-300 48-125DC
H3CR-FN-300 100-240AC
H3CR-FN-300 24AC/DC
H3CR-FN-300 12DC
H3CR-F8-300 48-125DC
H3CR-F8N-300 100-240AC
H3CR-F8N-300 24AC/DC
H3CR-F8N-300 12DC
Flicker ON start 100 to 240 VAC
24 VAC/DC
12 VDC
48 to 125 VDC
H3CR-FN 48-125DC
H3CR-F8N 48-125DC
H3CR-FN-300 48-125DC
H3CR-F8N-300 48-125DC
Note: Specify both the model number and supply voltage when ordering.
Example: H3CR-F 100-240AC
Supply voltage
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
1
H3CR-F
■ Accessories (Order Separately)
Name/specifications
Models
Flush Mounting Adapter
Y92F-30
Y92F-73
Y92F-74
PFP-50N
PFP-100N
PFP-100N2
PFP-M
Mounting Track
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
End Plate
Spacer
PFP-S
Protective Cover
Y92A-48B
P2CF-08
P2CF-08-E
P2CF-11
P2CF-11-E
P3G-08
Track Mounting/
Front Connecting Socket
8-pin
8-pin, finger safe type
11-pin
11-pin, finger safe type
8-pin
Back Connecting Socket
8-pin, finger safe type
11-pin
P3G-08 with Y92A-48G (See note 1)
P3GA-11
11-pin, finger safe type
For PL08 and PL11 Sockets
For PF085A Socket
P3GA-11 with Y92A-48G (See note 1)
Hold-down Clip (See note 2)
Y92H-7
Y92H-8
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket.
2. Hold-down Clips are sold in sets of two.
Specifications
■ General
Item
Operating mode
Pin type
H3CR-F
Flicker OFF start
11-pin
H3CR-F8
H3CR-FN
Flicker ON start
11-pin
H3CR-F8N
8-pin
8-pin
Operating/Reset method
Output type
Time-limit operation/Time-limit reset or self-reset
Relay output (DPDT)
Mounting method
Approved standards
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.
■ Time Ranges
0.05 s to 30 h Models
Time unit
s (sec)
×10 s (10 sec)
1.2 to 12
min (min)
0.12 to 1.2
h (hrs)
Setting
1.2
3
0.05 to 1.2
0.3 to 3
3 to 30
0.3 to 3
1.2 to 12
3 to 30
12
30
1.2 to 12
3 to 30
12 to 120
30 to 300
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
1.2 s to 300 h Models
Time unit
1.2
×10 s (10 sec)
1.2 to 12
×10 min (10 min)
1.2 to 12
h (hrs)
×10 h (10 hrs)
1.2 to 12
3 to 30
Setting
0.12 to 1.2
0.3 to 3
3
3 to 30
3 to 30
12
30
12 to 120
30 to 300
12 to 120
30 to 300
1.2 to 12
3 to 30
12 to 120
30 to 300
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
2
H3CR-F
■ Ratings
Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC
Operating voltage range
Power reset
85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models
Minimum power-opening time: 0.1 s
Power consumption
100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC
24 VAC/VDC:
approx. 2 VA (1.7 W) at 24 VAC
approx. 1 W at 24 VDC
48 to 125 VDC: approx. 1.5 W at 125 VDC
12 VDC: approx. 1 W at 12 VDC
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
Control outputs
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
■ Characteristics
Accuracy of operating
time
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 1.2 and 3 s)
Setting error
5% FS 50 ms max.
Reset time
0.1 s max.
Reset voltage
Influence of voltage
10% max. of rated voltage
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 1.2 and 3 s)
Influence of temperature 1% FS max. ( 1% FS 10 ms max. in ranges of 1.2 and 3s)
Insulation resistance
Dielectric strength
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand
voltage
3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC
1 kV for 12 VDC, 24 VAC/DC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to
125 VDC
1.5 kV for 12 VDC, 24 VAC/DC
Noise immunity
Static immunity
Vibration resistance
Shock resistance
1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
400 V for 12 VDC
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s2 three times each in six directions
Malfunction: 98 m/s2 three times each in six directions
Ambient temperature
Operating: −10°C to 55°C (with no icing)
Storage:
−25°C to 65°C (with no icing)
Ambient humidity
Life expectancy
Operating: 35% to 85%
Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)
EMC
(EMI)
EN61812-1
Emission Enclosure:
Emission AC Mains:
(EMS)
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
Immunity ESD:
IEC61000-4-2:
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900 5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
Immunity Burst:
Immunity Surge:
IEC61000-4-4:
IEC61000-4-5:
2 kV line to ground (level 3)
Case color
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 100 g
Degree of protection
Weight
Note: Refer to the Life-test Curve.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
3
H3CR-F
■ Life-test Curve
10,000
5,000
1,000
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
30 VDC L/R = 7 ms
500
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
250 VAC/30 VDC
(cosφ = 1)
100
250 VAC (cosφ = 0.4)
Load current (A)
Connections
■ Block Diagrams
Zero setting
detection
circuit
ON indicator OFF indicator
Indicator
circuit
ROM
RAM
Clock
Output
circuit
Power supply
circuit
Time range/unit
selectors
One-chip microcomputer
AC (DC) input
■ I/O Functions
Inputs
---
Outputs
Control output
Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob.
■ Terminal Arrangement
H3CR-F8
H3CR-F8
H3CR-F
H3CR-FN
NH3CR-F8-300
H3CR-F8N-300
H3CR-F-300
H3CR-FN-300
(+)(~)
Power supply
Power supply
Note: Leave terminals 5, 6, and 7 open.
Do not use them as relay terminals.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
4
H3CR-F
Operation
■ Timing Chart
tON: ON set time
tOFF: OFF set time
Operating mode
Flicker OFF start
Timing chart
0.1 s min.
ON
OFF
Power
t
OFF
t
ON
tOFF
t
ON
t
OFF
tOFF
Lit
Not lit
ON
indicator
Lit
Not lit
OFF
indicator
ON
OFF
Output
NO
ON
OFF
Output
NC
Flicker ON start
0.1 s min.
ON
Power
OFF
tON
tOFF
tON
tOFF
tON
tOFF
Lit
ON
indicator
Not lit
Lit
OFF
indicator
Not lit
ON
Output
NO
OFF
ON
Output
NC
OFF
Note: 1. The reset time requires a minimum of 0.1 s.
2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance
of the Timer.
Nomenclature
OFF indicator (green)
OFF-time unit display window
Lit when the output is OFF.
OFF-time unit selector (select one from sec.
10 s, min., and hrs, or from 10 s, 10 min, hrs,
and 10 h)
ON indicator (orange)
Lit when the output is ON.
Scale range display
windows
ON-time setting knob (with orange pointer)
For ON-time setting
OFF-time setting knob (with green pointer)
For OFF-time setting
Time range selector (select one
from 1.2, 3, 12, and 30 at full
scale)
ON-time unit display window
For both ON-time and OFF-time.
ON-time unit selector (select one
from sec, 10 s, min, and hrs, or from
10 s, 10 min, hrs, and 10 h)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
5
H3CR-F
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3CR-F
66.6
52.3
17.4
5.7
H3CR-FN
48
0.7
6
H3CR-F-300
H3CR-FN-300
44.8 × 44.8
37 dia.
14 dia.
48
R1.3
11 pins
17.4
5.7
66.6
52.3
H3CR-F8
H3CR-F8N
48
0.7
6
H3CR-F8-300
H3CR-F8N-300
37 dia.
14 dia.
44.8 × 44.8
48
R1.3
8 pins
Dimensions with Front Connecting Socket
P2CF-08-@/P2CF-11-@
Dimensions with Back Connecting Socket
P3G-08/P3GA-11
81.5
80
81.5
75
17.4
17.4
H3CR-F
H3CR-FN
H3CR-F8
H3CR-F8N
92.3*
90.0
103.2*
100.9
H3CR-F
H3CR-FN
H3CR-F8
H3CR-F8N
P3GA-11
P3G-08
Y92F-30
Y92F-30
(When
(When
2.3*
2.3*
Y92A-48G
mounted)
Y92A-48G
mounted)
P2CF-11
P2CF-11-E
P2CF-08
P2CF-08-E
*These dimensions vary with the kind of DIN track (reference value).
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
6
HSoli3d-sCtateRSta-r-Gdelta Timers
DIN 48 × 48-mm Star-delta Timer
• A wide star-time range (up to 120 seconds) and star-delta
transfer time range (up to 0.5 seconds).
Model Number Structure
■ Model Number Legend
H3CR - G 8 @ L @
1
2 3 4 5
5. Supply Voltage
100-120AC: 100 to 120 VAC
200-240AC: 200 to 240 VAC
1. Classification
G: Star-delta timer
2. Configuration
8: 8-pin socket
3. Outputs
None: Star-delta operation contact
E:
Star-delta operation contact
and instantaneous contact
4. Dimensions
L: Long-body model
Ordering Information
■ List of Models
Outputs
Supply voltage
100 to 120 VAC
200 to 240 VAC
100 to 120 VAC
200 to 240 VAC
8-pin models
Time-limit contact
H3CR-G8L 100-120AC
H3CR-G8L 200-240AC
H3CR-G8EL 100-120AC
H3CR-G8EL 200-240AC
Time-limit contact and instantaneous contact
Note: Specify both the model number and supply voltage when ordering.
Example: H3CR-G8L 100-120AC
Supply voltage
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
7
H3CR-G
Accessories (Order Separately)
Name/specifications
Models
Flush Mounting Adapter
Y92F-30
Y92F-70
Y92F-71
PFP-50N
PFP-100N
PFP-100N2
PFP-M
Mounting Track
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
End Plate
Spacer
PFP-S
Protective Cover
Y92A-48B
P2CF-08
P2CF-08-E
P3G-08
Track Mounting/
Front Connecting Socket
8-pin
8-pin, finger safe type
8-pin
Back Connecting Socket
8-pin, finger safe type
Setting a specific time
Limiting the setting range
Light gray (5Y7/1)
Black (N1.5)
P3G-08 with Y92A-48G (See note 1)
Time Setting Ring
Y92S-27
Y92S-28
Panel Cover (See note 2)
Y92P-48GL
Y92P-48GB
Y92P-48GM
Y92H-1
Medium gray (5Y5/1)
For PL08 and PL11 Sockets
For PF085A Socket
Hold-down Clip (See note 3)
Y92H-2
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket.
2. The Time Setting Ring and Panel Cover are sold together.
3. Hold-down Clips are sold in sets of two.
Specifications
■ General
Item
H3CR-G8L
H3CR-G8EL
Star-delta timer with instantaneous output
Functions
Pin type
Star-delta timer
8-pin
Operating/Reset method
Output type
Time-limit operation/Self-reset
Time-limit: SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Time-limit:
SPST-NO (star operation circuit)
SPST-NO (delta operation circuit)
Instantaneous: SPST-NO
Mounting method
DIN track mounting, surface mounting, and flush mounting
Approved standards
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.
■ Time Ranges
Time unit
Star operation time ranges
Full scale setting
6
0.5 to 6 s
12
60
120
1 to 12 s
5 to 60 s
10 to 120 s
Star-delta transfer time
Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
8
H3CR-G
■ Ratings
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)
Operating voltage range
Power reset
85% to 110% of rated supply voltage
Minimum power-opening time: 0.5 s
Power consumption
100 to 120 VAC: approx. 6 VA (2.6 W) at 120 VAC
200 to 240 VAC: approx. 12 VA (3.0 W) at 240 VAC
Control outputs
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
Note: 1. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
2. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
■ Characteristics
Accuracy of operating
time
0.2% FS max.
Setting error
5% FS 50 ms max.
25% FS + 5 ms max.
Accuracy of Star-delta
transfer time
Reset voltage
10% max. of rated voltage
0.2% FS max.
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
1% FS max.
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand
voltage
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
Noise immunity
Static immunity
1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Vibration resistance
Shock resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s2 three times each in six directions
Malfunction: 294 m/s2 three times each in six directions
Ambient temperature
Operating: −10°C to 55°C (with no icing)
Storage:
−25°C to 65°C (with no icing)
Ambient humidity
Life expectancy
Operating:
35% to 85%
Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (See note)
EMC
(EMI)
EN61812-1
Emission Enclosure:
Emission AC Mains:
(EMS)
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
Immunity ESD:
IEC61000-4-2:
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900 5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
Immunity Burst:
Immunity Surge:
IEC61000-4-4:
IEC61000-4-5:
2 kV line to ground (level 3)
Case color
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Degree of protection
Weight
H3CR-G8L: approx. 110 g; H3CR-G8EL: approx. 130 g
Note: Refer to the Life-test Curve.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
9
H3CR-G
■ Life-test Curve
10,000
5,000
1,000
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
30 VDC L/R = 7 ms
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
500
250 VAC/30 VDC
(cosφ = 1)
100
250 VAC (cosφ = 0.4)
Load current (A)
Connections
■ Block Diagrams
H3CR-G8L
Star
Star-delta
transfer time
selector
operation
time range
selector
Star operation
time
oscillation
circuit
Star
Star-delta
transfer time
oscillation
circuit
Star-delta
transfer time
counting
circuit
Power
supply
circuit
operation
time counting
circuit
AC input
Star operation
Delta operation
Output
circuit
Star
operation
indicator
Indicator
circuit
Delta
operation
indicator
H3CR-G8EL
Star
Star-delta
transfer time
selector
operation
time range
selector
Star operation
time
oscillation
circuit
Star
Star-delta
transfer time
oscillation
circuit
Star-delta
transfer time
counting
circuit
Power
supply
circuit
Star operation
Delta operation
operation
time counting
circuit
AC input
Output
circuit
Star
operation
indicator
Indicator
circuit
Delta
operation
indicator
Instantaneous
output circuit
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
10
H3CR-G
■ I/O Functions
Inputs
---
Outputs
Control output
If the time reaches the value set with the time setting knob, the star operation output will be turned OFF
and there will be delta operation output after the set star-delta transfer time has elapsed.
■ Terminal Arrangement
H3CR-G8L
H3CR-G8EL
Star
operation
contact
Delta
operation
contact
Star
operation
contact
Delta
operation
contact
Instantaneous contact
Note: Leave terminals 1, 3, and 4 open.
Note: Leave terminal 4 open. Do not use
Do not use them as relay terminals.
them as relay terminals.
Operation
■ Timing Chart
t1: Star operation time setting
t2: Star-delta transfer time
Model
Timing chart
0.5 s min.
H3CR-G8L/-G8EL
ON
OFF
Power (2 − 7)
ON
OFF
Instantaneous output
(1 − 3) (-E models)
t1
ON
OFF
t2
Star operation
output (8 − 5)
ON
OFF
Delta operation
output (8 − 6)
Lit
Not lit
Star operation indicator
Delta operation indicator
Lit
Not lit
Nomenclature
Star operation
indicator (green)
Delta operation
indicator (orange)
Time unit display
(sec is fixed)
Scale range display
windows
Time setting knob (for setting
star operation time)
Star-delta transfer time selector
(select one from 0.05 s, 0.1 s,
0.25 s, and 0.5 s)
Star operation time range selector
(select one from 6, 12, 60, and 120
at full scale)
Star-delta transfer time display window
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
11
H3CR-G
Dimensions
Note: All units are in millimeters unless otherwise indicated.
(78.0)
63.7
15
6
48
0.7
44.8 × 44.8
39 dia.
48
8 pins
Dimensions with Set Ring
16.5
50
42 dia.
50
Time setting ring
Panel cover
Dimensions with Front Connecting Socket
P2CF-08-@
Dimensions with Back Connecting Socket
P3G-08
92.9
15
86.4
H3CR-G8@L
99
101.3*
H3CR-
G8@L
P3G-08
Y92F-30
(When
Y92A-48G
mounted)
2.3*
P2CF-08
P2CF-08-E
*These dimensions vary with the kind of DIN track (reference value).
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
12
HSoli3d-sCtateRPow-eHr OFF-delay Timers
DIN 48 × 48-mm Power OFF-delay Timer
• Long power OFF-delay times;
S-series: up to 12 seconds,
M-series: up to 12 minutes.
• Models with forced-reset input are available.
• 11-pin and 8-pin models are available.
Model Number Structure
■ Model Number Legend
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for
availability.
H3CR - H @ @ L @ @
1
2
3
4
5
6
6. Time Range
1. Classification
H: Power OFF-delay timer
2. Configuration
3. Input
5. Supply Voltage
100-120AC: 100 to 120 VAC
200-240AC: 200 to 240 VAC
S:
0.05 to 12 s
None: Without reset input
M:
0.05 to 12 min
R:
With reset input
48DC:
48 VDC
4. Dimensions
None: 11-pin socket
100-125DC: 100 to 125 VDC
8:
8-pin socket
L:
Long-body model
■ List of Models
Input Output Supply voltage
S-series
M-series
11-pin models
8-pin models
11-pin models
8-pin models
Without DPDT 100 to 120 VAC ---
H3CR-H8L 100-120AC S ---
H3CR-H8L 200-240AC S
H3CR-H8L 24AC/DC S
H3CR-H8L 48DC S
H3CR-H8L 100-120AC M
H3CR-H8L 200-240AC M
H3CR-H8L 24AC/DC M
H3CR-H8L 48DC M
reset
input
200 to 240 VAC
24 VAC/DC
48 VDC
100 to 125 VDC
H3CR-H8L 100-125DC S
H3CR-H8L 100-125DC M
With
reset
input
100 to 120 VAC H3CR-HRL 100-120AC S ---
200 to 240 VAC H3CR-HRL 200-240AC S
H3CR-HRL 100-120AC M ---
H3CR-HRL 200-240AC M
H3CR-HRL 24AC/DC M
H3CR-HRL 48DC M
24 VAC/DC
48 VDC
H3CR-HRL 24AC/DC S
H3CR-HRL 48DC S
100 to 125 VDC H3CR-HRL 100-125DC S
SPDT 100 to 120 VAC ---
H3CR-HRL 100-125DC M
H3CR-H8RL 100-120AC S ---
H3CR-H8RL 100-120AC M
H3CR-H8RL 200-240AC M
H3CR-H8RL 24AC/DC M
H3CR-H8RL 48DC M
200 to 240 VAC
24 VAC/DC
H3CR-H8RL 200-240AC S
H3CR-H8RL 24AC/DC S
H3CR-H8RL 48DC S
48 VDC
100 to 125 VDC
H3CR-H8RL 100-125DC S
H3CR-H8RL 100-125DC M
Note: Specify the model number, supply voltage, and time range (S or M) when ordering.
Example: H3CR-H8L 100-120AC S
Time range
Supply voltage
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
13
H3CR-H
■ Accessories (Order Separately)
Name/specifications
Models
Flush Mounting Adapter
Y92F-30
Y92F-70
Y92F-71
PFP-50N
PFP-100N
PFP-100N2
PFP-M
Mounting Track
50 cm (l) × 7.3 mm (t)
1 m (l) × 7.3 mm (t)
1 m (l) × 16 mm (t)
End Plate
Spacer
PFP-S
Protective Cover
Y92A-48B
P2CF-08
P2CF-08-E
P2CF-11
P2CF-11-E
P3G-08
Track Mounting/
Front Connecting Socket
8-pin
8-pin, finger safe type
11-pin
11-pin, finger safe type
8-pin
Back Connecting Socket
8-pin, finger safe type
11-pin
P3G-08 with Y92A-48G (See note 1)
P3GA-11
11-pin, finger safe type
For PL08 and PL11 Sockets
For PF085A Socket
P3GA-11 with Y92A-48G (See note 1)
Hold-down Clip (See note 2)
Y92H-1
Y92H-2
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket.
2. Hold-down Clips are sold in sets of two.
Specifications
■ General
Item
H3CR-H8L
H3CR-H8RL
H3CR-HRL
Operating/Reset method
Instantaneous operation/Time-limit Instantaneous operation/Time-limit reset/Forced reset
reset
Pin type
8-pin
11-pin
Input type
---
No-voltage
Output type
Relay output (DPDT)
Relay output (SPDT)
Relay output (DPDT)
Mounting method
Approved standards
DIN track mounting, surface mounting, and flush mounting
UL508, CSA C22.2 No.14, NK, Lloyds
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.
Output category according to EN60947-5-1.
■ Time Ranges
Time unit
S-series
s (sec)
M-series
min (min)
Setting
0.6
1.2
6
0.05 to 0.6
0.12 to 1.2
0.6 to 6
12
1.2 to 12
0.1 s min.
3 s min.
Min. power ON time
2 s min.
Time-up operation repeat period
Forced-reset repeat period
3 s min.
Note: 1. If the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time.
2. Do not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions
(H3CR-H) on page 8 for details.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
14
H3CR-H
■ Ratings
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC (50/60 Hz), 48 VDC,
100 to 125 VDC
Operating voltage range
85% to 110% of rated supply voltage
ON-impedance: 1 kΩ max.
ON residual voltage: 1 V max.
No-voltage input (See note 3.)
OFF impedance:
500 kΩ min.
Power consumption
100 to 120 VAC: approx. 0.23 VA (0.22 W) at 120 VAC
200 to 240 VAC: approx. 0.35 VA (0.3 W) at 240 VAC
24 VAC/DC:
approx. 0.17 VA (0.15 W) at 24 VAC
approx. 0.1 W at 24 VDC
48 VDC:
approx. 0.18 W at 48 VDC
100 to 125 VDC: approx. 0.5 W at 125 VDC
Control outputs
Contact output: 5 A at 250 VAC/30 VDC, resistive load (cosφ = 1)
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model.
2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details.
3. For contact input, use contacts which can adequately switch 1 mA at 5 V.
■ Characteristics
Accuracy of operating
time
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s)
Setting error
5% FS 50 ms max.
Operation start voltage
Influence of voltage
30% max. of rated voltage
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s)
Influence of temperature 1% FS max. ( 1% FS 10 ms max. in ranges of 0.6 and 1.2 s)
Insulation resistance
Dielectric strength
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
Impulse withstand
voltage
3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;
1 kV for 24 VAC/DC, 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to
240 VAC, 100 to 125 VDC;
1.5 kV for 24 VAC/DC, 48 VDC
Noise immunity
1.5 kV (between power terminals) and 600 V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 μs, 1-ns rise); 1 kV (between power terminals) for 48 VDC
Static immunity
Malfunction: 8 kV, Destruction:15 kV
Vibration resistance
Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s2 three times each in six directions
Shock resistance
Malfunction: 98 m/s2 three times each in six directions
Ambient temperature
Operating: −10°C to 55°C (with no icing),
Storage:
−25°C to 65°C (with no icing)
Ambient humidity
Life expectancy
Operating: 35% to 85%
Mechanical: 10 million operations min. (under no load at 1,200 operations/h)
Electrical:
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note)
EMC
(EMI)
EN61812-1
Emission Enclosure:
Emission AC Mains:
(EMS)
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
Immunity ESD:
IEC61000-4-2:
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900 5 MHz) (level 3)
Immunity Conducted Disturbance: IEC61000-4-6:
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
Immunity Burst:
Immunity Surge:
IEC61000-4-4:
IEC61000-4-5:
2 kV line to ground (level 3)
Case color
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 120 g
Degree of protection
Weight
Note: Refer to the Life-test Curve.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
15
H3CR-H
■ Life-test Curve
10,000
5,000
1,000
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)
30 VDC L/R = 7 ms
500
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC for H3CR-H8L/-HRL
and 100 mA at 5 VDC for H3CR-H8RL (failure level: P).
250 VAC/30 VDC
(cosφ = 1)
100
250 VAC (cosφ = 0.4)
Load current (A)
Connections
■ Block Diagrams
Without Reset Input (H3CR-H8L)
Time range/
unit selector
Power supply
circuit
Oscillation
circuit
Counting
circuit
Output
circuit
AC (DC) input
Power failure
detection circuit
Indicator
circuit
Output
indicator
With Reset Input (H3CR-H8RL/-HRL)
Time range/
unit selector
Power supply
AC (DC) input
Oscillation
circuit
Counting
circuit
Output
circuit
circuit
Indicator
circuit
Output
indicator
Power failure
detection circuit
Reset input
Input circuit
■ I/O Functions
Inputs
Reset
Turns off the control output and resets the elapsed time.
Outputs
Control output
Operates instantaneously when the power is turned on and time-limit resets when the set time is up
after the power is turned off.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
16
H3CR-H
■ Terminal Arrangement
Note: DC models, including 24 VAC/DC models, have polarity.
8-pin Models
Without Reset Input (H3CR-H8L)
With Reset Input (H3CR-H8RL)
Reset
input
Power supply
Power supply
Note: Leave terminal 3 open. Do not use
them as relay terminals.
11-pin Model
With Reset Input (H3CR-HRL)
Reset input
Power supply
Note: Leave terminal 6 open. Do not use
them as relay terminals.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
17
H3CR-H
Operation
■ Timing Chart
t:
Set time
Rt: Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.)
If the power ON time is less than this value, the Timer may not operate (i.e., output may not turn ON).
Model
H3CR-H8L
Timing chart
Rt
Rt
t
t
ON
Power
(See note)
OFF
Output (1 − 3)
Output (1 − 4)
Output (8 − 6)
Output (8 − 5)
Lit
Not lit
Output
indicator
H3CR-H8RL
Rt
Rt
ON
t
t
Power
(See note)
OFF
0.05 s min.
0.05 s min.
ON (Short-circuited)
OFF (Open)
Reset input
Output (8 − 6)
Output (8 − 5)
Lit
Not lit
Output
indicator
Rt
H3CR-HRL
Rt
ON
OFF
t
t
Power
(See note)
0.05 s min.
0.05 s
min.
Reset input
Output (1 − 3)
Output (1 − 4)
Output (11 − 9)
Output (11 − 8)
Lit
Not lit
Output
indicator
Note: If the power is turned ON until the set time is up, the timer will be retriggered.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
18
H3CR-H
Nomenclature
Output indicator (red)
Scale range display windows
Time setting knob (for setting
power OFF-delay time)
Time range selector (select
one from 0.6, 1.2, 6, and 12 at
full scale)
Time unit display
S-series: sec
M-series: min
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3CR-H8L
H3CR-H8RL
15
6
78.0
63.7
48
0.7
48
39 dia.
44.8 × 44.8
8 pins
H3CR-HRL
15
6
78.0
63.7
48
0.7
44.8 × 44.8
48
39 dia.
11 pins
Dimensions with Front Connecting Socket
P2CF-08-@/P2CF-11-@
Dimensions with Back Connecting Socket
P3G-08/P3GA-11
92.9
91.4
92.9
86.4
15
15
H3CR-H8@L
H3CR-HRL
101.3*
99
112.2*
109.9
2.3*
H3CR-
H8@L
H3CR-HRL
P3GA-11
P3G-08
Y92F-30
Y92F-30
(When
Y92A-48G
mounted)
(When
Y92A-48G
mounted)
2.3*
P2CF-08
P2CF-08-E
P2CF-11
P2CF-11-E
*These dimensions vary with the kind of DIN track (reference value).
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
19
H3CR-H
Safety Precautions (H3CR-H)
Note: The undermentioned is common for all H3CR-H models.
■ Power Supplies
The H3CR-H has a large inrush current; provide sufficient power
supply capacity. If the power supply capacity is too small, there may
be delays in turning ON the output.
■ Wiring
The H3CR-H has a high impedance circuit. Therefore, the H3CR-H
may not be reset if the H3CR-H is influenced by inductive voltage. In
order to eliminate any influence of inductive voltage, the wires
connected to the H3CR-H must be as short as possible and should
not be installed alongside power lines. If the H3CR-H is influenced by
inductive voltage that is 30% or more of the rated voltage, connect a
CR filter with a capacitance of approximately 0.1 μF and a resistance
of approximately 120 Ω or a bleeder resistor between the power
supply terminals. If there is any residual voltage due to current
leakage, connect a bleeder resistor between the power supply
terminals.
With the H3CR-H@RL, for the power supply of an input device, use
an isolating transformer, of which the primary and secondary
windings are mutually isolated and the secondary winding is not
grounded.
Correct
H3CR-H@RL
Input terminal
10, 7*
2, 2*
4*, 7
Power supply
■ Operation
1*, 5
An interval of 3 s minimum is required to turn on the H3CR-H after
the H3CR-H is turned off. If the H3CR-H is turned on and off
repeatedly with an interval of shorter than 3 s, abnormal heating or
burning may occur in internal elements.
:H3CR-H8RL
*
3 s min.
Isolation transformer is required.
Power
Input device
Incorrect
H3CR-H@RL
Output
state 1
10, 7*
4*, 7
1*, 5
Input
terminal
Power
supply
2, 2*
Output
state 2
After the forced reset function of the H3CR-H is activated, an interval
of 3 s minimum is required to activate the forced reset function again.
If the forced reset function is activated repeatedly with an interval of
shorter than 3 s, the internal parts of the H3CR-H may deteriorate
and the H3CR-H may malfunction.
:H3CR-H8RL
*
Input device
Isolation
transformer
Power
3 s min.
3 s min.
■ Input/Output (H3CR-H@RL)
Reset
input
An appropriate input is applied to the input signal terminal of the
Timer when the input terminal for the input signal is short-circuited.
Do not attempt to connect any input terminal to any terminal other
than the input terminal or to apply voltage across other than the
specified input terminals or the internal circuits of the Timer may be
damaged.
Output
If it is required that the output be turned on repeatedly with an
interval of shorter than 3 s, consider use of the H3CR-A in mode D
(signal OFF-delay).
The H3CR-H@RL uses transformerless power supply. When
connecting a relay or transistor as an external signal input device,
pay attention to the following points to prevent short-circuiting due to
a sneak current to the transformerless power supply.
■ Others
If the H3CR-H is dropped or experiences some other kind of shock,
because a latching relay is used for output, contacts may be reversed
or go into a neutral state. If the H3CR-H is dropped, reconfirm correct
operation.
If input is made simultaneously from one input contact or a transistor
to the H3CR-H and a Timer whose common input terminals are used
as power terminals, such as the H3CR-A, a short-circuit current will
be generated. Either input through isolated contacts, or isolate the
power supply for one of the Timers.
H3CR-H@RL
10, 7*
4*,
7
2, 2*
1*, 5
Short-circuit current
G. S. R.
5
10
2
7
6
H3CR-A
*: H3CR-H8RL
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
20
Safety Precautions for All Timers
Refer to the Safety Precautions for individual Timers for precautions specific to each Timer.
• Normal operation may not be possible in locations subject to
!WARNING
sulfidizing gas, such as in sewer systems or waste incinerators.
OMRON does not market any Timers or other control devices for
operation in atmospheres containing sulfidizing gas. Seal the Timer
so that sulfidizing gas will not enter it. If sealing is not possible,
OMRON does provide special Timers with improved resistance to
sulfidizing gas. Ask your OMRON representative for details.
The following Timers contain lithium batteries that are
not explosion proof.
1. Timers with Built-in Batteries: H5L
The Timer contains a lithium battery, which may occasionally
ignite or rupture. Do not disassemble, deform under pressure,
heat to 100°C or higher, or incinerate the Timer.
Power Supply
• Be sure that the voltage applied is within the specified range,
2. Timers with Replaceable Batteries: Y92S-20 (for H5CN-M)
The battery may occasionally rupture, ignite, or leak fluid. Do
not short the positive and negative terminals. Do not charge,
disassemble, deform under pressure, or throw the battery into a
fire. If a non-specified battery is used, the battery may leak fluid
or rupture, occasionally resulting in equipment failure or minor
injury. Use only the specified battery.
otherwise the internal elements of the Timer may be damaged.
• Install a switch or circuit breaker that allows the operator to
immediately turn OFF the power, and label it to clearly indicate its
function.
• Maintain voltage fluctuations
in the power supply within
the specified range.
Allowable
Voltage Range
!CAUTION
The following Timers contain lithium batteries that are
explosion proof.
• Use a commercial power supply for the power supply voltage input
to models with AC inputs.
Inverters with an output frequency of 50/60 Hz are available, but
the rise in the internal temperature of the Timer may result in
ignition or burning. Do not use an inverter output for the power
supply of the Timer.
• The Timers listed below cannot be directly turned ON and OFF by
using an AC 2-wire proximity sensor to turn the Timer's power
supply ON and OFF.
Timers with Built-in Batteries:H5BR, H5AN-4DM, H5S, H5F, and
H4KV
The Timer contains a lithium battery, which may occasionally
ignite or rupture. Do not disassemble, deform under pressure,
heat to 100°C or higher, or incinerate the Timer.
Use the following countermeasure when using an AC 2-wire
proximity sensor with the Timer. (The power supply circuit in the
Timer uses half-wave rectification. Only a half AC wave is supplied
to the proximity sensor, which may cause operation to be unstable.)
■ Precautions for Safe Use
Operating Environment
Applicable Models
H3Y, H3YN, H3RN, H3CA-8, RD2P, and H3CR(-A, -A8, -AP, -F, and
-G)
• Use the Timer within the ratings specified for ambient operating
temperature and ambient operating humidity for each model.
• Store the Timer with the specified temperature range for each
model. If the Timer has been stored at a temperature of less than
−10°C, allow the Timer to stand at room temperature for at least 3
hours before using it.
Countermeasure
Wire through a relay and use the relay contacts to turn the power
supply ON and OFF.
Confirm the stability of operation after making the connections.
• Use the Timer within the performance specified for water and oil
exposure for each model.
• Install protective measures (such as earth leakage breakers, wiring
breakers, or fuses) on the power supply side according to any
applicable laws or regulations.
• Do not use the Timer in locations subject to shock and vibration.
Long-term usage in such locations may damage the Timer due to
stress.
Magnetic contactors generate a shock of 1,000 to 2,000 m/s2 when
switching a load. When mounting to DIN Track, separate magnetic
contactors from the Timer so that the Timer is not subjected to
vibration and shock. Use anti-vibration rubber.
• Do not use the Timer in locations subject to excessive dust,
corrosive gases, or direct sunlight.
• Do not use organic solvents (such as paint thinner or benzine),
strong alkalis, or strong acids because they will damage the
external finish of the Timer.
• Separate the input devices, input wiring, and Timer as far as
possible from sources of noise and power lines carrying noise.
• When using the Timer in environments subject to large amounts of
static electricity (e.g., pipes carrying molding materials, powders, or
fluid materials), separate the Timer as far as possible from the
sources of static electricity.
• Do not remove the external case from the Timer.
• Do not use the Timer in locations where condensation may occur
due to high humidity or sudden temperature changes.
Condensation inside the Timer may result in malfunction or
damage to Timer elements.
• The life of internal parts may be reduced if Timers are mounted in
close proximity to each other.
• Resin and rubber parts (e.g., rubber packing) may deteriorate,
shrink, or harden depending on the operating environment (e.g.,
subjected to corrosive gases, ultraviolet light, or high
temperatures). We recommend periodic inspection and
replacement.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
C-1
Correctly Handling Input Signals
Other Precautions
• Confirm that you have the correct model before using it.
Malfunction due to noise may occur if input wiring is placed in the
same duct or conduit as power lines or high-voltage lines. Separate
input wiring from power lines and wire them in a separate system.
Also, use shielded cables, use metal conduits, and keep wiring
distances as short as possible.
• Be sure that all terminals are wired correctly.
• Always test the output status with a tester before using a Timer with
a built-in keep relay (e.g., the H3CR-H and H3DE-H). Shock
resulting from dropping the Timer during transport or handling may
cause the output contacts to reverse or to be in a neutral status.
• Leaving the Timer with outputs ON at a high temperature for a long
time may hasten the degradation of internal parts (such as
electrolytic capacitors). Use the Timer in combination with relays
and avoid leaving the Timer with the output turned ON for an
extended period of time (e.g., for more than a month).
Timers with Relays
• Do not connect a load that exceeds contact ratings, such as the
switching capacity (contact voltage or contact current). Insulation
faults, contact welding, contact faults, and other failures to achieve
specified performance may occur and the relay may be damaged or
may burn.
Reference Example (Use the Timer as shown below.)
• Continued use with deteriorated performance may ultimately result
in insulation breakdown between circuits or relay burning. The life
of the built-in relay is greatly affected by switching conditions.
Before using the Timer, test operation under actual application
conditions and confirm that the switching frequency presents no
problems in performance.
X2/b
T/a
X1/a
X1/a
X
Auxiliary relay
(e.g., MY Relays)
T
X1
X2
• Electrical life depends on the type of load, switching frequency, and
ambient environment. Observe the following precautions when
using the Timer. When switching a DC load, contact transfer may
cause the contacts to stick or may cause contact failure. Confirm
applicability and consider using a surge absorbing element. When
switching at high frequencies, heat generated by arcing may cause
contacts to melt or may cause metal corrosion. Consider
connecting an arc absorbing element, reducing the switching
frequency, or lowering the humidity.
• Be sure that only a qualified worker (e.g., an electrical engineer)
performs electrical work for the Timer.
• The surge current depends on the type of load, which also affects
contact switching frequency and the number of operations. Check
the rated current and the surge current, and design the circuits with
sufficient margin.
Resistive load Solenoid load
Motor load
Incandescent
lamp load
Rated current
10 to 20 times 5 to 10 times
10 to 20 times
the rated
current
the rated
current
the rated
current
Sodium light
loads
Capacitor
loads
Transformer
loads
Mercury light
loads
1 to 3 times the 20 to 40 times 5 to 15 times
rated load
1 to 3 times the
the rated load the rated load rated load
• Arcing when switching and relay heating may result in ignition or
explosion. Do not use the Timer in atmospheres subject to
inflammable or explosive gases.
• Contact faults may occur. Do not use the Timer in atmospheres
subject to sulfidizing gas, chloride gas, or silicon gas.
• The switching capacity for DC voltage loads is lower than that for
AC voltage loads.
Timers with Non-contact Outputs
• Short faults or open faults may occur due to destruction of the
output element. Do not use the Timer for a load that exceeds the
rated output current.
• Short faults or open faults may occur due to destruction of the
output element from reverse electromotive force. When using the
Timer for a DC inductive load, always connect a diode as a
countermeasure against reverse electromotive force.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
http://www.ia.omron.com/
C-2
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the product.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission.
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
2007.3
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.