Solid-state Power OFF-delay Timer  
H3CR-H  
1/16 DIN, Analog-Set Timer with  
Power-OFF Delay, Four Selectable  
Ranges  
Extended power-OFF delay timer, up to  
12 seconds, for S-type and 12 minutes  
for M-type models  
Forced resetting type provides a  
manual override of the timing function  
11-pin and 8-pin models are available  
Red LED output indicator  
Ordering Information  
TIMERS  
Timing function  
Contact type  
Power-OFF delay  
DPDT  
SPDT  
Forced resetting  
Timing units  
Available  
Available  
S-series  
(seconds)  
M-series  
(minutes)  
S-series  
(seconds)  
M-series  
(minutes)  
S-series  
(seconds)  
M-series  
(minutes)  
Terminal form  
Supply voltages  
Part number  
11-pin models  
8-pin models  
100 to 120 VAC, 200 to 240 VAC, 24 VAC/DC  
H3CR-HRL H3CR-H8L  
H3CR-H8RL  
Note: Specify both the supply voltage and time unit code (S or M) in addition to the model number when ordering.  
Example: H3CR-H8L 24 VAC/DC  
M
Time unit code  
Supply voltage  
MODEL NUMBER LEGEND  
H3CR -  
1
2
3
4
1. Classification  
H: Power OFF-delay timer  
3. Input  
None: Without reset input  
R: With reset input  
2. Configuration  
None: 11-pin socket  
8: 8-pin socket  
4. Dimensions  
L: Long-body model  
H3CR-H  
H3CR-H  
ACCESSORIES (ORDER SEPARATELY)  
Description  
Part Number  
Panel mounting  
adapters  
Fits behind panel, ideal for side by side installation. Use P3G-08 socket.  
Y92F-30  
Y92F-70  
Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G-08  
socket, Fits 65-66 mm (2.56 - 2.59 in) x 52-53 (2.04 x 2.09 in) panel cutout. Charcoal gray face  
plate measures 88 H x 58 W mm (3.46 x 2.28 in)  
Installs through panel front; timer face fits bezel, rear of timer clips to adapter. Use P3G-08  
socket, Fits 55 x 45 mm (2.17 x 1.77 in) panel cutout. Charcoal gray face plate measures 58 H  
x 50 W mm (2.28 x 1.97 in)  
Y92F-71  
Mounting Track  
DIN rail, 50 cm (1.64 ft) length, 7.3 mm (0.29 in) depth  
DIN rail, 1 m (3.28 ft) length, 7.3 mm (0.29 in) depth  
DIN rail, 1 m (3.28 ft) length, 16 mm (0.63 in) depth  
End Plate  
PFP-50N  
PFP-100N  
PFP-100N2  
PFP-M  
Spacer  
PFP-S  
Protective Cover  
Sockets  
Hard plastic cover protects against dust dirt and water: not for use with panel covers.  
Bottom surface or track mounting, top screw terminals. Use with 8-pin terminal form timer.  
Bottom surface or track mounting, top screw terminals. Use with 11- pin terminal form timer.  
Y92A-48B  
P2CF-08  
P2CF-11  
P3G-08  
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals. Use with  
8-pin terminal form timer.  
Back mounting, for use with Y92F-30 mounting adapter, bottom screw terminals. Use with  
11-pin terminal form timer.  
P3GA-11  
RANGE SELECTION  
Output indicator (red)  
Time range  
Setting  
S-series  
M-series  
minutes  
Scale range display windows  
seconds  
0.05 to 0.6  
0.1 to 1.2  
0.5 to 6  
0.6  
1.2  
6
12  
1 to 12  
Time setting knob  
(for setting power  
OFF-delay time)  
Min. power ON time  
0.1 sec  
min.  
2 sec  
min.  
Note: If the above minimum power ON time is not secured, the  
H3CR may not operate. Be sure to secure the above mini-  
mum power ON time.  
Time range  
selector (select one  
from 0.6, 1.2, 6, 12)  
Time unit display  
S-series: sec  
M-series: min  
H3CR-H  
H3CR-H  
Specifications  
Part number  
H3CR-H8L  
H3CR-H8RL  
H3CR-HRL  
Supply voltage (see  
note)  
AC  
100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz)  
24 VAC/VDC (50/60 Hz)  
AC/DC  
Operating voltage  
85% to 110% of rated supply voltage  
Power consumption  
AC  
100 to 120 VAC: 0.18 VA (100 VAC applied)  
200 to 240 VAC: 0.25 VA (200 VAC applied)  
AC/DC  
24 VAC/DC: 0.24 VA (24 VAC applied)/140 mW (24 VDC applied)  
Start, Reset, Gate inputs  
Control outputs  
ON-impedance: 1k max.  
ON residual voltage: 1 V max.  
OFF impedance: 500 k min  
Type  
DPDT relay  
SPDT relay  
DPDT relay  
Max. load  
Min. load  
5 A at 250 VAC, p.f. = 1  
10 mA at 5 VDC  
Repeat accuracy  
Setting error  
±0.3% full scale max. (±0.3% full scale max.±10 ms in ranges of 0.6 and 1.2 s)  
±5% full scale ±0.05 s max.  
Resetting system  
Instantaneous operation/ Instantaneous operation/Time-limit reset/  
Time-limit reset  
Forced reset  
Resetting time  
Indicators  
50 ms min.  
Output ON indicator (red LED)  
Materials  
Plastic case (light gray Munsell 5Y7/1)  
Panel, track, or surface depending on socket selected  
Mounting  
Connections  
Weight  
11-pin round socket  
8-pin round socket  
Approx. 120 g (4.23 oz.)  
UL/CSA/CE (EMC) (LV)  
Approvals  
Ambient temperature  
Operating  
Storage  
--10° to 55°C (14° to 131°F) with no icing  
--25° to 65°C (--13° to 149°F) with no icing  
35% to 85%  
Humidity  
Vibration  
Mechanical durability  
Malfunction durability  
Mechanical durability  
Malfunction durability  
10 to 55 Hz with 0.75-mm single amplitude each in three directions  
10 to 55 Hz with 0.5-mm single amplitude each in three directions  
2
Shock  
980 m/s (100G) each in three directions  
2
98 m/s (10G) each in three directions  
Variation due to voltage change  
±0.5% full scale max. (±0.5% full scale max. ±10 ms in ranges of 0.6 and 1.2 s)  
±2% full scale max. (±2% full scale max. ±10 ms in ranges of 0.6 and 1.2 s)  
10 million operations min. (under no load at 1,200 operations/h)  
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)  
100 M min. (at 500 VDC)  
Variation due to temperature change  
Service life  
Mechanical  
Electrical  
Insulation resistance  
Note: A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC model.  
H3CR-H  
H3CR-H  
Engineering Data  
10,000  
5,000  
1,000  
Note:  
A maximum current of 0.15 A can be switched at 125 VDC (cos = 1)  
30 VDC L/R = 7 ms  
500  
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In  
both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 10 mA at 5 VDC (failure level: P).  
250 VAC/30 VDC  
(cos = 1)  
100  
250 VAC (cos = 0.4)  
Load current (A)  
Operation  
BLOCK DIAGRAMS  
Without Reset Input (H3CR-H8L)  
Time range  
selector  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output  
circuit  
AC (DC) input  
Power failure  
detection circuit  
Indicator  
circuit  
Output  
indicator  
With Reset Input (H3CR-H8RL/-HRL)  
Time range  
selector  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output  
circuit  
AC (DC) input  
Power failure  
detection circuit  
Indicator  
circuit  
Output  
indicator  
Input circuit  
Reset input  
H3CR-H  
H3CR-H  
Timing Charts  
H3CR-H8L  
Rt  
Rt  
t
t
ON  
Power  
OFF  
Output (1 -- 3)  
Output (1 -- 4)  
Output (8 -- 6)  
(--)  
(~)  
(+)  
(~)  
Power supply  
Output (8 -- 5)  
Output  
indicator  
Lit  
Not lit  
H3CR-H8RL  
Rt  
Rt  
ON  
OFF  
t
t
Power  
0.05 s min.  
0.05 s min.  
ON (Short-circuited)  
OFF (Open)  
Reset input  
Reset  
input  
(--)  
(~)  
(+)  
(~)  
Output (8 -- 6)  
Output (8 -- 5)  
Power supply  
Output  
indicator  
Lit  
Not lit  
Note: Leave terminal 6 open. Do not use  
them as relay terminals.  
Rt  
Rt  
ON  
t
t
H3CR-HRL  
Power  
OFF  
0.05 s min.  
Reset input  
0.05 s  
min.  
Reset input  
Output (1 -- 3)  
Output (1 -- 4)  
Output (11 -- 9)  
(--)(~)  
(+)(~)  
Power supply  
Output (11 -- 8)  
Output  
Note: Leave terminal 3 open. Do not use  
them as relay terminals.  
Lit  
Not lit  
indicator  
Note: t: Set time  
Rt: Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.)  
H3CR-H  
H3CR-H  
Dimensions  
Unit: mm (inch)  
TIMERS  
H3CR-H8L  
H3CR-H8RL  
15  
78.0 (3.07)  
63.7  
48 (1.89)  
0.7  
6
48  
(1.89)  
39 dia  
(1.54)  
44.8 (1.76) x  
44.8 (1.75  
15  
78.0 (3.07)  
63.7  
48 (1.89)  
H3CR-HRL  
0.7  
6
39 dia  
(1.54)  
48  
(1.89)  
44.8 (1.76) x  
44.8 (1.75  
TRACK MOUNTING  
11-Pin models  
8-Pin models  
P2CF-08  
P2CF-11  
H3CR-HRL  
H3CR-H8L  
H3CR-H8RL  
111.7*  
109.4  
100.7*  
98.4  
2.3*  
*These dimensions vary with the kind of DIN track (reference value).  
2.3*  
H3CR-H  
H3CR-H  
PANEL MOUNTING  
11-Pin models  
8-Pin models  
P3G-08  
Y92F-30  
15  
P3GA-11  
Y92F-30  
15  
85.4  
91.4  
H3CR-H8L  
H3CR-H8RL  
H3CR-HRL  
PANEL MOUNTING ADAPTERS  
Y92F-30  
Adapter installs behind the panel. It is ideal for side by side installation. Use P3G-08 sockets  
Panel Cutout  
Panel  
+0.6  
--0  
0.5 R max.  
45  
(N)  
+0.6  
--0  
58  
(2.28)  
52  
(2.05)  
45  
Note: Recommended panel  
thickness should be 1  
to 3.2 mm.  
Y92F-70  
Panel Cutout  
Panel  
Adapter mounting hole Two, 4.5 dia.  
R0.5 max.  
65 to 66  
52 to 53  
45  
0.15  
88  
(3.46)  
76 0.2  
45 0.15  
58 (2.28)  
Note: The mounting panel thickness  
Y92F-71  
should be 1 to 3.2 mm.  
Panel  
R0.5 max.  
+0.5  
--0  
45  
58  
(2.28)  
+0.5  
--0  
68  
(2.68)  
55  
45 0.2  
43 0.2  
Note: The mounting panel thickness  
+0.2  
--0  
50  
should be 1 to 3.2 mm.  
(1.97)  
H3CR-H  
H3CR-H  
SOCKETS  
Track mounting/front connecting socket  
P2CF-08  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Eight  
M3.5 x 7.5 sems  
3
4.5  
7.8  
Surface Mounting Holes  
Two, 4.5 dia. or two, M4  
70 max.  
35.4  
(1.39)  
Two 4.5 dia.  
holes  
40 0.2  
4
50 max.  
20.3 max.  
P2CF-11  
3
4.5  
Eleven  
M3.5 x 7.5 sems  
Two, 4.5 dia. mounting holes  
40 0.2  
7.8  
35.4  
(1.39)  
70 max.  
Two 4.5 dia.  
holes  
4
50 max.  
31.2 max.  
Back mounting socket  
P3G-08  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
27 dia.  
45  
(1.77)  
4.9  
45  
(1.77)  
17  
(0.67)  
P3GA-11  
27 dia.  
45  
(1.77)  
25.6  
6.2  
45  
(1.77)  
4.5  
16.3  
(0.64)  
PROTECTIVE COVER  
Y92A-48B  
The hard plastic protective cover prevents  
accidental resetting. It also shields the front  
panel from dirt and water. The cover is  
intended for use in areas where unusual  
service conditions do not exist. The Y92A-48B  
cover cannot be used with the Y92P Panel  
Covers below.  
50.5  
(1.99)  
16 (0.63)  
overall depth  
50.5  
(1.99)  
H3CR-H  
H3CR-H  
MOUNTING TRACK AND ACCESSORIES  
PFP-100N, PFP-50N  
PFP-100N2  
16  
7.3 0.15  
4.5  
4.5  
27  
29.2  
1.5  
24  
1
27 0.15  
35 0.3  
35 0.3  
15 25  
25  
25  
25 15  
*
15 25  
25  
25  
25  
1
10  
10  
15(5)  
(see note)  
10  
10  
1,000 (500)  
(see note)  
L
Note: The values shown in parentheses are for the PFP-50N.  
PFP-M End Plate  
PFP-S Spacer  
16  
12  
10  
6.2  
5
1.8  
1
35.5 35.3  
50  
34.8  
44.3  
1.8  
11.5  
1.3  
4.8  
M4 x 8  
pan head  
screw  
10  
16.5  
Connections  
Part number  
Input terminal number  
Power supply terminal numbers  
AC (common), DC-- AC (hot), DC+  
Output terminal numbers  
COM  
Reset  
COM  
NC  
NO  
H3CR-H8L  
2
7
1
8
4
5
3
6
H3CR-H8RL  
H3CR-HRL  
1
5
4
7
2
2
7
8
5
6
10  
1
11  
4
8
3
9
Installation  
INPUT CONNECTIONS  
OUTPUT CONNECTIONS  
)
)
(H3CR-H  
-
(H3CR-H  
-
The neutral or common of the power supply is connected to  
terminal 2. Terminal 7 of H3CR-H8L/H8RL and terminal 10 of  
H3CR-HRL should be connected to the “hot” or positive of the  
power supply. Terminals 1 and 4 of H3CR-H8RL and terminals  
5 and 7 of H3CR-HRL are used for no-voltage forced resetting.  
Do not connect these terminals to power.  
Design your control circuit using the relay contacts to switch the  
load. Never switch a load with the contact that is being used  
as an input signal. The timer’s circuitry may be damaged.  
H3CR-H  
H3CR-H  
SELECTING TIME RANGES  
A time range (0 to 1.2, 0 to 3, 0 to 12, or 0 to 30) is selected for ON-  
and OFF-time using the time range selector at the lower left corner  
of the front panel, and the selected time range appears within the  
plastic frame of the time setting knob (= scale range display win-  
dows).  
TRACK MOUNTING  
Using P2CF-  
Socket  
Mounting  
The P2CF--  
Removal  
socket has two hooks that  
Pull the latch on the socket with a flat--blade  
screwdriver and remove the timer and sock-  
et as one unit.  
secure the time to the socket. Be sure to  
allow at least 20 mm (0.79 in) clearance  
above and below the socket to gain access  
to release the hooks for servicing and  
maintenance. Then clip rear of the socket  
to the track. Push the bottom onto the  
track until the latch hooks securely.  
Hook  
20 mm  
(0.79 in)  
P2CF-11  
or P2CF-08  
socket  
Using Y92F-70 and Y92F-71 Adapters  
Install the H3CR-H timer, face first, into the  
back side of the Y92F-70 or Y92F-71  
adapter so the bezel fits snuggly. Be sure  
the retaining clips at the back of the adapter  
fit into the slots on either side of the timer.  
Compress the top and bottom tabs of the  
adapter then push the adapter through the  
front side of the panel cutout. Be sure the  
tabs extend after the installation for a  
secure fit.  
Installation  
Mounting tabs  
Panel  
Retaining clips  
for timer  
To remove the timer from the adapter,  
unclip the two retaining clips at the back of  
the adapter. To remove the adapter and  
timer from the panel as a unit, compress  
the tabs behind the panel and push the unit  
out the front of the panel.  
Mounting tabs  
Precautions  
CAUTIONS  
To avoid malfunction or damage, do not change the time unit or time  
range while the timer is in operation. Be sure to turn off the power  
supply to the timer before changing any of the selections.  
WIRING PRECAUTIONS  
H3CR  
Except for the wiring of the power supply circuit, avoid laying input  
signal wires in parallel or in the same conduit with high tension or  
power lines. Use shielded wires or wiring with independent metal  
conduits for the shortest possible distance.  
Input  
terminal  
Power supply  
Never touch the input terminals while power is being applied to the  
timer to prevent electric shock.  
Use an isolation transformer for the power supply of an input device.  
Thetransformer’s primary andsecondary windings should bemutu-  
ally isolated and the secondary winding not grounded.  
Circuit  
Isolation transformer is required.  
H3CR-H  
H3CR-H  
ENVIRONMENT  
When using the Timer in an area with excess electronic noise, sepa-  
rate the Timer, wiring, and the equipment which generates the input  
ference..signals as far as possible from the noise sources. It is also  
recommended to shield the input signal wiring to prevent electronic  
interference.  
Organic solvents (such as paint thinner), as well as very acidic or  
basic solutions can damage the outer casing of the Timer  
OTHERS  
If the Timer is mounted on a control board, remove the timer from  
the control board or short-circuit the circuitry of the power board be-  
fore carrying out a voltage withstand test between the electric cir-  
cuitry and non current-carrying metal part of the Timer, to prevent  
the internal circuitry of the Timer from damage.  
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.  
OMRON ELECTRONICS, INC.  
OMRON CANADA, INC.  
One East Commerce Drive  
885 Milner Avenue  
Schaumburg, IL 60173  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC TI8  
11/97  
Specifications subject to change without notice.  
Printed in U.S.A.  

相关型号:

H3CR-H8L-120VAC-S

Analog Circuit
OMRON

H3CR-H8L-240VAC-M

Analog Circuit
OMRON

H3CR-H8L-240VAC-S

Analog Circuit
OMRON

H3CR-H8L-24VAC/DC-M

Analog Circuit
OMRON

H3CR-H8L-24VAC/DC-S

Analog Circuit
OMRON

H3CR-H8RL

Solid-state Twin Timers
OMRON

H3CR-H8RL-120VAC-M

Analog Circuit
OMRON

H3CR-H8RL-120VAC-S

Analog Circuit
OMRON

H3CR-H8RL-240VAC-M

Analog Circuit
OMRON

H3CR-H8RL-240VAC-S

Analog Circuit
OMRON

H3CR-HRL

Solid-state Twin Timers
OMRON

H3CR-HRL-120VAC-M

Analog Circuit
OMRON