H7EC-P [OMRON]
Analog Circuit;型号: | H7EC-P |
厂家: | OMRON ELECTRONICS LLC |
描述: | Analog Circuit |
文件: | 总6页 (文件大小:90K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PC Board-Use Counter
H7E-P
Miniature Counter for PC Board Usage
■ LSI with built-in digital filter ensures
excellent noise immunity
■ Machine insertable
■ Can be mounted on 28-pin IC socket
■ Totalizing counter, time counter and
tachometer available
Ordering Information
■ TOTALIZING COUNTERS
Operating mode
Display
UP type
LCD digital, 5.1 mm (0.2 in) high
External (electrical) reset, power-OFF reset
Reset system
Number of digits
Count input
7
No-voltage (solid-state) input
No-voltage (contact, solid-state) input
Max. counting speed 1 kcps
30 cps
Mounting style
Mounts directly on PCB, or with 28-pin IC socket
Part number
H7EC-P
H7EC-LP
■ TIME COUNTER
Operating mode
Display
UP type
LCD digital, 5.1 mm (0.2 in) high
External (electrical) reset, power-OFF reset
7 (0.0 to 999999.9 h)
Reset system
Number of digits
Count input
No-voltage (contact, solid-state) input
Mounts directly on PCB, or with 28-pin IC socket
H7ET-P
Mounting style
Part number
■ DIGITAL TACHOMETERS
Operating mode
Display
UP type
LCD digital, 5.1 mm (0.2 in) high
Reset system
Automatic (No external or manual reset)
4
Number of digits
Count input
5
No-voltage (solid-state) input
1 kcps
DC voltage input
Max. counting speed
Applicable encoder resolution
Max. revolutions displayed
Mounting style
10 kcps
1 pulse/rev
60 pulses/rev
10,000 rpm
1,000 rps
Mounts directly on PCB, or with 28-pin IC socket
Part number
H7ER-P
H7ER-VP
H7ER-V2P
■ ACCESSORIES
Connecting socket
Description
Part number
XR2A-2801-N
28-pin (standard quality)
H7E-P
H7E-P
Specifications
■ RATINGS
Supply voltage
3 VDC
Operating voltage range
Current consumption
90 to 110% of supply voltage
Models H7EC-❑P and H7ER-P: 20 µA max. (at 3 VDC, 25°C/77°F)
Model H7ET-❑❑P: 15 µA max. (at 3 VDC, 25°C/77°F)
Input*
DC Voltage input:
4.5 to 30 VDC at "High" (logic) level
0 to 2 VDC at "Low" (logic) level
(input impedance: approx. 4.7 kΩ)
No-voltage input:
Maximum short-circuit impedance: 10 kΩ max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 500 kΩ min.
Max. counting speed**
H7EC-P (1 kcps): Minimum signal width 0.5 ms
H7EC-LP (30 cps): Minimum signal width 16.7 ms
H7ER-P, -VP (1 kcps): Minimum signal width 0.5 ms
H7ER-V2P (10 kcps): Minimum signal width 0.05 ms
Reset time
External reset types: 20 ms
Power-OFF type reset time: 100 ms (with 0 V residual voltage at power OFF)
Gate time (H7ER only)
1 second
* The maximum voltages allowed on the input, count or gate terminals are as follows:
No-voltage models: 3 VDC
DC voltage models: 30 VDC
** ON/OFF ratio 1:1
Approved by the following standards
UL
CSA
CE (EMC)
■ CHARACTERISTICS
Noise immunity
Vibration
±200 V between input terminals with square-wave noise applied by noise simulator
Mechanical durability: 10 to 55 Hz; 0.75 mm (0.03 in) double amplitude
Malfunction durability: 10 to 55 Hz; 0.3 mm (0.02 in) double amplitude
Mechanical durability: Approx. 30 G
Shock
Malfunction durability: Approx. 10 G
Ambient temperature
Operating: -10° to 55°C (14° to 131°F)
Storage: -25° to 65°C (-13° to 149°F)
Humidity
Weight
35 to 85% RH
Approx. 20 g (1.25 oz)
2
H7E-P
H7E-P
Dimensions
Unit: mm (inch)
33.02
5.08
0.6
5.08
Eight straight PCB
terminals
3.3
0.5
17.3 (0.68)
Detailed drawing
of straight
0.6
0.3
PCB terminal
max.
t=0.3
Base
3.3
0.6
Mounting footprint
Eight 0.8-dia
holes*
2.54
8.2
Area occupied by counter
(0.88)
22.4
2.54
8
3.58
15.24
3.58
32.1
44.8 (1.76)
15.24
5.08
5.08
5.9
5.9
33.02
0.3
Note: Mounting hole dimensions conform to the pin
pitch of a standard 28-pin IC socket.
*When machine inserting the H7E❑-❑P, the mounting
holes must be 1.2 mm diameter.
3
H7E-P
H7E-P
Connections
■ H7EC-P, H7EC-PL, H7ET-P
■ H7ER-P, H7ER-VP, H7ER-V2P
Use a diode (Di) having a forward voltage as small as possible
(0.1 V max. at IF of 1 mA). Determine the ratio of R1 to R2 in
accordance with the forward voltage of the diode to be used.
Be aware that when the supply voltage of power source E has
dropped to less than the voltage of the backup circuit, the
battery discharges. To protect the circuit against a momentary
power failure, an aluminum electrolyte capacitor can also be
used in place of a battery, as shown below:
Power supply
All H7E❑-❑P models require a 3 VDC external power source.
When designing a circuit, plan the power wiring connections to
be within 50 mm (1.97 in). Refer to the connection diagrams
above for proper wiring polarity.
The life expectancy of a battery power source can be calcu-
lated by the following formula:
t = 1000 A/lc
where,
t: life expectancy of battery (h)
A: battery capacity (mAh)
lc: current consumed by H7E❑-❑P (µA)
When the capacitor is used, its backup time can be calculated
by the following formula*:
Voltage division of power source circuit
When necessary, the voltage from the battery may be divided
by resistances:
t = C(V1 -V2)/lc
where,
t: Backup time (s)
C: Capacitance (µF)
V1: Supply voltage before power failure (V)
V2: Minimum operating voltage of H7E❑-❑P (V)
lc: H7E❑-❑P current consumption (µA)
* In all applications which require the counter to maintain the
accumulated display for a longer time, increase the capaci-
tance to an appropriate value.
When doing so, however, ensure that the following equation
balances:
Input connection
Contact input
E (V) x R2 / (R1 + R2) = 3V
Allow a current high enough to flow through R1 so that the
H7E❑-❑P receives adequate current.
C is a film capacitor, of about 0.1 µF, and is intended to absorb
noise superposed from the power lines.
Keep wiring between the H7E❑-❑P and R2 as short as
possible, within 50 mm (1.97 in).
Backup circuit for protection against power failure
4
H7E-P
H7E-P
■ SOLID-STATE INPUT OF OPEN-COLLECTOR TRANSISTOR
By open-collector transistor
By TTL or C-MOS IC
Use a transistor for input that satisfies the following conditions:
Collector breakdown voltage ≥ (Circuit voltage) x 1.2
Leakage current < 5 µA
Amplification factor (hFE)≥ 50
Use diode (Di) having a forward voltage as small as possible
(0.1 V max. at IF of 20 µA).
Operations
PCB counter power source
Wiring
Wiring polarity must be carefully observed in order to prevent
permanent damage to the counter. The 28-pin socket has no
provision for preventing the insertion of the counter in a
reversed position. Exercise caution when inserting the counter
in the socket, to prevent reversed polarity.
Do not route the count, gate or reset input wiring in the vicinity
of, or in parallel to the wiring of high-voltage or inductive load
circuits (such as motors and relays). Also, keep the wiring as
short as possible.
Replacing battery
To prevent unwanted reset when replacing the battery, connect
the new battery before disconnecting the old one. Otherwise,
the voltage supplied to the counter circuit drops, causing the
present count value to reset.
When designing the circuit board, providing two extra terminals
for battery connection will make the switch much simpler. See
the schematic diagram below:
5
H7E-P
H7E-P
■ GENERAL INFORMATION
The terminals are solder-plated. Finish soldering the terminals
within 5 seconds, at a solder iron tip temperature of 250°±10°C
(482°F±50°F). Since the counter is not flux-tight, do not use
flux when soldering. Avoid automatic and dip soldering.
Manually solder the counter onto a PC board, and avoid
cleaning as much as possible.
When mounting the counter on a PC board with components
which consume higher current than the counter, place the
counter in the vicinity of the power supply. Avoid placing the
counter in a circuit with power-consuming components. Above
all, never place the count input circuit in a circuit common to
power-consuming components.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches, divide by 25.4.
OMRON ELECTRONICS, INC.
One East Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC CN4A
6/98/26M
Specifications subject to change without notice.
Printed in the U.S.A.
6
相关型号: