MKS2P-2AC240 [OMRON]

Power/Signal Relay, DPDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;
MKS2P-2AC240
型号: MKS2P-2AC240
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, DPDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT

光电二极管
文件: 总10页 (文件大小:2424K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Relays  
MKS  
Exceptionally Reliable General Purpose  
Relay now available with Lockable Test  
Button  
• IEC Rating of 7A 250 V AC 50/60 Hz,  
General use 100,000 cycles.  
• Mechanical indicator standard for all models.  
• Optional features include lockable test button, LED  
indicator, diode surge suppression, varistor, reverse  
polarity, and alternate wiring styles.  
• UL (RU/CRU), CE and TUV approved.  
• RoHS Compliant.  
Features  
Two-way Action Test Button (Models with Lockable Test Button)  
Relay in  
Normal Operation  
For Momentary  
Operation  
For Lock  
Operation  
Yellow  
button  
Slide the latching lever  
to the first position,  
then press the yellow  
button with an insulated  
tool to operate the  
contact.  
Slide the latching lever  
to the second position.  
(The contact is now in  
the locked position.)  
Note: The latching lever is Red for AC Coil versions and Blue for DC Coil versions.  
Model Number Structure  
Model Number Legend  
MKS@@@@@-@-@  
1 2 3 4 5  
6
7
1. Contact Form  
5. Coil Polarity  
Blank: Standard  
2:  
3:  
DPDT  
3PDT  
1:  
Reverse polarity (DC coil only)  
2. Terminals  
P: Plug-in  
6. Surge Absorption  
Blank:Standard  
3. Mechanical Indicator/Test Button  
D:  
V:  
Surge absorber diode (DC coil only)  
Surge absorber varistor (AC coil only)  
Blank:Mechanical indicator  
I:  
Mechanical indicator and lockable test button  
7. Internal Connections DPDT  
4. LED Indicator  
Blank: Standard  
Blank: Standard  
2 or 5: Non-standard connections.(Refer to “Terminal Arrange-  
ment/Internal Connection (Bottom View)”.)  
N:  
LED indicator  
8. Rated Voltage  
(Refer to “Coil Ratings”.)  
General Purpose Relays MKS  
299  
Ordering Information  
List of Models  
Type  
Terminals Contact form  
Internal connections  
(See note 3.)  
With mechanical indicator With mechanical indicator Coil ratings  
and lockable test button  
Basic  
Models  
Plug-in  
DPDT  
3PDT  
Standard  
MKS2P  
MKS2PI  
AC/DC  
AC/DC  
DC  
Non Standard  
Standard  
MKS2P-2  
MKS2PI-2  
MKS3P  
MKS3PI  
Non Standard  
MKS3P-2  
MKS3PI-2  
MKS3P-5  
MKS3PI-5  
Models with  
LED Indicator  
(See note 2.)  
DPDT  
3PDT  
Standard  
MKS2PN(1)  
MKS2PN(1)-2  
MKS3PN(1)  
MKS3PN(1)-2  
MKS3PN(1)-5  
MKS2P(1)-D  
MKS2P(1)-D-2  
MKS3P(1)-D  
MKS3P(1)-D-2  
MKS3P(1)-D-5  
MKS2PN-D  
MKS2PN-D-2  
MKS3PN-D  
MKS3PN-D-2  
MKS3PN-D-5  
MKS2P-V  
MKS2PIN(1)  
MKS2PIN(1)-2  
MKS3PIN(1)  
MKS3PIN(1)-2  
MKS3PIN(1)-5  
MKS2PI(1)-D  
MKS2PI(1)-D-2  
MKS3PI(1)-D  
MKS3PI(1)-D-2  
MKS3PI(1)-D-5  
MKS2PIN-D  
MKS2PIN-D-2  
MKS3PIN-D  
MKS3PIN-D-2  
MKS3PIN-D-5  
MKS2PI-V  
Non Standard  
Standard  
Non Standard  
Models with  
Diode  
(See note 2.)  
DPDT  
3PDT  
Standard  
Non Standard  
Standard  
Non Standard  
Models with  
LED Indicator  
and Diode  
DPDT  
3PDT  
Standard  
DC  
Non Standard  
Standard  
Non Standard  
Models with  
Varistor  
DPDT  
3PDT  
Standard  
AC  
Non Standard  
Standard  
MKS2P-V-2  
MKS3P-V  
MKS2PI-V-2  
MKS3PI-V  
Non Standard  
MKS3P-V-2  
MKS3P-V-5  
MKS2PN-V  
MKS2PN-V-2  
MKS3PN-V  
MKS3PN-V-2  
MKS3PN-V-5  
MKS3PI-V-2  
MKS3PI-V-5  
MKS2PIN-V  
MKS2PIN-V-2  
MKS3PIN-V  
MKS3PIN-V-2  
MKS3PIN-V-5  
Models with  
LED Indicator  
and Varistor  
DPDT  
3PDT  
Standard  
AC  
Non Standard  
Standard  
Non Standard  
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.  
Example: MKS2P DC48  
Rated voltage  
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.  
Refer to Terminal Arrangement and Internal Connections.  
Example: MKS3PN1-5 DC24  
Reverse coil polarity  
3. Refer to Terminal Arrangement and Internal Connections for all wiring diagrams.  
10A Sockets (Order Separately)  
Item  
Type  
Model  
Track-mounted  
Socket  
8-pin  
PF083A-E  
11-pin  
8-pin  
PF113A-E  
PF083A-D  
PF113A-D  
PFC-A1  
11-pin  
Hold-down Clip  
(For PF083A-E and PF113A-E)  
300  
General Purpose Relays MKS  
Specifications  
Ratings  
Coil Ratings  
Rated voltage  
Rated current  
Coil resistance  
Must operate  
voltage  
Must release  
voltage  
Max. voltage  
Power  
consumption  
50 Hz  
443 mA  
221 mA  
110 mA  
26.6 mA  
24.2 mA  
22.2 mA  
13.3 mA  
12.1 mA  
11.5 mA  
11.0 mA  
224 mA  
112 mA  
55.8 mA  
28.1 mA  
13.5 mA  
12.3 mA  
10.8 mA  
60 Hz  
385 mA  
193 mA  
96.3 mA  
23.1 mA  
21.0 mA  
19.3 mA  
11.6 mA  
10.5 mA  
10.0 mA  
9.6 mA  
AC  
6 V  
3.1 Ω  
80% max. of rated 30% min. of rated 110% of rated volt- Approx. 2.3 VA  
voltage  
voltage at 60 Hz age  
25% min. of rated  
voltage at 50 Hz  
at 60 Hz  
Approx. 2.7 VA  
at 50 Hz  
12 V  
13.7 Ω  
48.4 Ω  
760 Ω  
24 V  
100 V  
110 V  
120 V  
200 V  
220 V  
230 V  
240 V  
6 V  
932 Ω  
1,130 Ω  
3,160 Ω  
3,550 Ω  
4,250 Ω  
4,480 Ω  
26.7 Ω  
107 Ω  
DC  
15% min. of rated  
voltage  
Approx. 1.4 W  
12 V  
24 V  
430 Ω  
48 V  
1,710 Ω  
7,390 Ω  
8,960 Ω  
11,576 Ω  
100 V  
110 V  
125 V  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for AC rated current and  
15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.  
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.  
Contact Ratings  
Load  
Resistive load  
(cosφ = 1)  
Inductive load  
(p.f. = 0.4)  
Contact mechanism  
Contact material  
Rated load  
Single  
AgSnIn  
NO 10 A, 250 VAC  
7 A, 250 VAC  
10A, 30 VDC  
NC 5 A, 250 VAC  
5 A, 30 VDC  
Rated carry current  
10 A  
Max. switching voltage  
Max. switching current  
Max. switching capacity  
250 VAC, 250 VDC  
10 A  
NO 2,500 VA/300 W  
NC 1,250 VA/150 W  
General Purpose Relays MKS  
301  
Characteristics  
Contact resistance  
100 mΩ max.  
Operate time  
AC: 20 ms max.  
DC: 30 ms max.  
Release time  
20 ms max.(40 ms max. for built-in diode models)  
Max. operating frequency  
Mechanical: 18,000 operations/hr (no load)  
Electrical:1,800 operations/hr (at rated load)  
Insulation resistance  
Dielectric strength  
100 MΩ min. (at 500 VDC)  
2,500 VAC 50/60 Hz for 1 min. between coil and contacts  
1,000 VAC 50/60 Hz for 1 min. between contacts of same polarity and terminals of the same polarity  
2,500 VAC 50/60 Hz for 1 min. between current-carrying parts, non-current-carrying parts, and opposite  
polarity  
Insulation method  
Basic insulation  
Impulse withstand voltage  
4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave)  
3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave)  
Pollution degree  
3
Rated insulation voltage  
Vibration resistance  
250 V  
Destruction:10 to 55 Hz, 1.5 mm double amplitude  
Malfunction:10 to 55 Hz, 1.0 mm double amplitude  
Destruction:1,000 m/s2 (approx. 100 G)  
Malfunction:100 m/s2 (approx. 10 G)  
Mechanical: 5,000,000 operations min.  
Electrical:100,000 operations min.  
Shock resistance  
Life expectancy  
10 mA at 1 VDC P level: λ60=0.1 x 10-6 / ops  
Operating: –40 to 60°C (with no icing or condensation)  
Operating: 5% to 85%  
Min. permissible load  
Ambient temperature  
Ambient humidity  
Weight  
Approx. 90 g  
Note: 1. The values given above are initial values.  
2. Ambient temperature of models with LED indicator is 25 to 60°C.  
Approved Standards  
UL Recognized (File No. E41515) - - Ambient Temp. = 40°C  
IEC Standard/TUV Certification: IEC61810-1  
(Certification No. R50104853)  
Coil ratings  
Contact ratings  
Operations  
Coil ratings  
6, 12, 24, 48, N.O.  
100, 110 VDC contact 10 A, 30 V DC (Resistive)  
6, 12, 24, 100,  
110, 200, 220,  
240 VAC  
Contact ratings  
10 A, 250 V AC 50/60 Hz (Resistive) 100,000  
Operations  
6 to 110 VDC N.O.  
10 A, 250 V AC 50/60 Hz (Resistive) 100,000  
6 to 240 VAC contact 10 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
N.C.  
10 A, 250 V AC 50/60 Hz (Resistive) 100,000  
7 A, 250 V AC 50/60 Hz (General Use)  
contact 10 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
N.C.  
5 A, 250 V AC 50/60 Hz (Resistive)  
contact 5 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
100,000  
Note: 10A UL ratings are with no load on the other contact set.  
Note: Maximum carrying current per TUV Certification is 9 A when  
new MK-S relays are mounted in PF083A-E or PF113A-E  
Sockets.  
CSA Certified (File No. LR35535)  
Coil  
Number  
of Poles  
Contact ratings  
Operations  
ratings  
6 to 125 VDC  
6 to 240 VAC  
2
3
10 A, 250 V AC (Resistive)  
10 A, 30 V DC (Resistive)  
7 A, 250 V AC (General Use)  
100,000  
10 A, 250 V AC (Resistive)  
Same Polarity  
100,000  
10 A, 30 V DC (Resistive)  
Same Polarity  
7 A, 250 V AC (General Use)  
Same Polarity  
302  
General Purpose Relays MKS  
Engineering Data  
Reference Data  
Maximum Switching Power  
Rated Carry Current vs. Ambient Rated Temperature  
100  
50  
10  
30  
DC resistive load  
UL derating curve  
with NO contact  
AC resistive load  
with NO contact  
10  
5
AC inductive  
load  
(p.f. = 0.4)  
5
3
AC resistive load  
with NC contact  
DC resistive  
load with  
NC contact  
0
40  
1
10  
30  
50  
100  
300 500 1.000  
20  
0
20  
40  
60  
80  
Ambient temperature (°C)  
Switching voltage (V)  
Note: The lower limit of the ambient operating temperature for models  
with built-in operation indicators is 25°C.  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Models without Test Button  
Models with Lockable Test Button  
34.5 max.  
34.5 max.  
34.5 max.  
0.8  
52.5 max.  
34.5 max.  
0.8  
52.5 max.  
Track Mounted Sockets  
See below for Socket dimensions.  
Poles  
Finger-protection models  
Maximum carry current 10 A  
5 A  
2 poles  
PF083A-E  
PF083A-D  
PF083A  
3 poles  
PF113A-E  
PF113A-D  
PF113A  
Note: If using the PF083A or PF113A Sockets, be sure the maximum carrying current is 5 A or less. When using finger-protection sockets, make  
sure the connecting wire terminals are Y-shaped.  
General Purpose Relays MKS  
303  
PF083A-E (Conforming to EN 50022)  
PF113A-E (Conforming to EN 50022)  
Terminal Arrangement  
Terminal Arrangement  
Eight, M3.5 × 7 sems  
Eleven, M3.5 × 7 sems  
7
4
7
4
52 max.  
35.4  
52 max.  
35.4  
2
3.5  
33  
41 max.  
Mounting Holes  
Mounting Holes  
21 max.  
3.5  
2
4
34  
42.8 max.  
Two, M4 or two 4.5-dia. holes  
Two, M4 or two 4.5-dia. holes  
31 max.  
33 0.2  
33 0.2  
PF083A-D  
PF113A-D  
8
Terminal Arrangement  
Terminal Arrangemen  
8
24 22 12 14  
21  
32 24 22 12  
6
5
4
3
6
5.5  
8
7
5 4  
5.5  
27  
4
27  
4
Eight, M4 screws  
Eight, M4 screws  
9
34  
3
14  
10  
A2  
2
A1  
7
8
1
2
11  
31  
1
11  
A2 21 11 A1  
Mounting Holes  
Two, M4 or two 4.5-dia. hole  
Mounting Holes  
Two, M4 or two 4.5-dia. hol  
65  
65  
30  
30  
38  
38  
Hold-down Clips  
Mounting Height with Sockets  
PFC-A1  
(2 pieces per set)  
Three  
poles  
Two  
poles  
4.6  
87.8  
(See  
note.)  
77.8  
(See  
note.)  
84.3  
74.3  
60.8  
62  
PF083A(-E)  
PF113A(-E)  
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.  
6
4.5  
Mounting Tracks  
PFP-100N, PFP-50N  
(Conforming to EN 50022)  
PFP-100N2  
(Conforming to EN 50022)  
16  
7.3 0.15  
35 0.3  
4.5  
4.5  
27  
35 0.3  
29.2  
1.5  
24  
27 0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
**  
1
15 (5)  
10  
10  
10  
10  
1000 4  
1000 (500)*  
* The figure in parenthesis is for PFP-50N.  
** A total of twelve 25 x 4.5 elliptic holes is provided with six  
holes cut from each track end at a pitch of 10 mm.  
304  
General Purpose Relays MKS  
(Bottom View)  
Terminal Arrangement/Internal Connection  
MKS2P(I)  
MKS2P(I)-2  
MKS3P(I)  
MKS3P(I)-2  
MKS3P(I)-5  
Basic Models  
(AC/DC Coil)  
5
5
4
4
6
5
7
6
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
8
4
8
4
3
9
9
3
9
3
1
8
1
8
2
10  
10  
2
10  
2
1
11  
11  
1
11  
1
MKS2P(I)N  
MKS2P(I)N-2  
MKS3P(I)N  
MKS3P(I)N-2  
MKS3P(I)N-5  
LED Indicator Type  
(AC Coil)  
5
5
4
4
6
5
7
3
2
3
2
6
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
1
11  
MKS2P(I)N  
MKS2P(I)N-2  
MKS3P(I)N  
MKS3P(I)N-2  
MKS3P(I)N-5  
LED Indicator Type  
(DC Coil:  
Standard Polarity)  
5
5
4
4
6
6
5
7
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
1
11  
MKS2P(I)N1  
MKS2P(I)N1-2  
MKS3P(I)N1  
MKS3P(I)N1-2  
MKS3P(I)N1-5  
LED Indicator Type  
(DC Coil:  
Reverse Polarity)  
5
5
4
4
6
6
5
7
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
8
4
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
1
11  
MKS2P(I)-D  
MKS2P(I)-D-2  
MKS3P(I)-D  
MKS3P(I)-D-2  
MKS3P(I)-D-5  
Diode Type  
(DC Coil:  
5
5
4
4
Standard Polarity)  
6
6
7
5
3
2
3
2
6
7
6
7
6
7
5
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
11  
1
1
11  
1
11  
MKS2P(I)1-D  
MKS2P(I)1-D-2  
MKS3P(I)1-D  
MKS3P(I)1-D-2  
MKS3P(I)1-D-5  
Diode Type  
(DC Coil:  
5
5
4
4
Reverse Polarity)  
6
6
5
3
2
3
2
7
6
7
6
7
6
5
7
5
7
4
8
4
8
4
8
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
1
11  
General Purpose Relays MKS  
305  
MKS2P(I)N-D  
MKS2P(I)N-D-2  
MKS3P(I)N-D  
MKS3P(I)N-D-2  
MKS3P(I)N-D-5  
LED Indicator and  
Diode Type  
(DC Coil)  
5
5
4
4
6
7
6
5
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
4
8
8
4
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
11  
1
MKS2P(I)-V  
MKS2P(I)-V-2  
MKS3P(I)-V  
MKS3P(I)-V-2  
MKS3P(I)-V-5  
Varistor Type  
(AC Coil)  
5
5
4
4
6
6
3
2
3
2
6
7
6
7
5
7
6
5
7
5
7
4
8
4
8
4
8
3
3
9
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
11  
1
MKS2P(I)N-V  
MKS2P(I)N-V-2  
MKS3P(I)N-V  
MKS3P(I)N-V-2  
MKS3P(I)N-V-5  
LED Indicator and  
Varistor Type  
(AC Coil)  
5
5
4
4
6
5
7
6
3
2
3
2
6
7
6
7
6
5
7
5
7
4
8
8
4
4
8
3
9
3
9
3
9
1
8
1
8
2
10  
2
10  
2
10  
1
11  
1
11  
1
11  
Safety Precautions  
Safety Precautions for Correct Use  
Installation  
Recommend mounting MK-S Relay so that side with wiring diagram is facing down.  
Handling  
Check coil polarity when wiring LED Indicator and Diode Models.  
Test Button  
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.  
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.  
Check that the test button is released before turning ON relay circuits.  
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.  
Use an insulated tool when you operate the test button.  
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the  
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only  
the requirements for basic insulation are fulfilled.  
306  
General Purpose Relays MKS  
MEMO  
General Purpose Relays MKS  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
General Purpose Relays MKS  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY