New Product
Switch Mode Power Supply
(15/30/60/90/120/180/240/480-W Models)
S8VS
60/90/120/180/240/480-W Models
New Models with Indication
MonitorandSimpleFunctions
for Easy System
Commissioning
• New 90-W models with indication monitor that
conform to UL Class 2 Output standards.
• New models with screwless terminal blocks
and indication monitor.
• Status displayed on 3-digit, 7-segment display.
• Safety standards:
UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1
EN 50178 (= VDE 0160)
EN 60950-1 (= VDE 0805 Teil 1)
• Input conditions: DC input is also possible from 80 to 370 VDC
(Not compliant with EC Directives and other safety standards.)
15/30-W Models
Compact, Thin Power Supplies
That Mount Just About Anywhere
to Contribute to Control Panel
Downsizing
• Compact and thin: 22.5 × 85 × 96.5 mm (W × H × D).
• Three mounting directions
(standard, horizontal, facing horizontal).
• Mounting directly to the panel is possible.
• Safety standards:
UL 508/60950-1,
CSA C22.2 No.107.1/60950-1,
EN 50178 (= VDE 0160),
EN 60950-1 (= VDE 0805 Teil 1)
• Input conditions: DC input is also possible from 80 to 370 VDC
(Not compliant with EC Directives and other safety standards.)
Features Common to All Models
• Mount to DIN Rail.
• Complies with SEMI F47-0706 (200-VAC input).
• RoHS-compliant.
Refer to Safety Precautions for All Power Supplies and Safety
Precautions on page 32.
!
1
S8VS
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below.
S8VS- @@@@@@@@-@
1
2
3 4 5
6
1. Power Ratings
015: 15 W
030: 30 W
4. Alarm output
None: Sinking (Emitter COM) *
P:
Sourcing (Collector COM)
060: 60 W
Note: No alarm output possible with 60-W models.
* Both sinking and sourcing outputs are available for 480-W models.
090: 90 W
120: 120 W
180: 180 W
240: 240 W
480: 480 W
5. UL Class 2 Output Standards (UL 1310)
None: Does not conform. *
S:
Conforms.
* 15-W, 30-W, and 60-W models conform to Class 2 output standards
(UL 1310).
Note: The S option is available only for 90-W models.
2. Output voltage
05: 5 V
12: 12 V
24: 24 V
6. Terminal Block Form
None: Screw terminal block
F:
Screwless terminal block
3. Indication monitor
None: Without indication monitor (standard model)
A:
B:
With indication monitor (maintenance forecast monitor)
With indication monitor (total run time monitor)
BE: With indication monitor but without alarm output (total run
time monitor)
Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.
2
S8VS
Ordering Information
List of Models
Note: For details on normal stock models, contact your nearest OMRON representative.
Models without Indication Monitor (Standard Models)
UL Class 2
Model number
Model number
Power ratings
Input voltage
Output voltage
5 V
Output current
2.0 A
Output standards
(screw terminal block)
(screwless terminal block)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
S8VS-01505 *1
S8VS-01512
S8VS-01524
S8VS-03005 *2
S8VS-03012
S8VS-03024
S8VS-06024
S8VS-09024
S8VS-09024S
S8VS-12024
S8VS-18024
S8VS-24024
15 W
12 V
24 V
5 V
1.2 A
0.65 A
4.0 A
2.5 A
1.3 A
2.5 A
---
30 W
12 V
24 V
100 to 240 VAC
(allowable range:
85 to 264 VAC or
80 to 370 VDC
*3)
60 W
90 W
S8VS-06024-F
S8VS-09024-F
S8VS-09024S-F
S8VS-12024-F
S8VS-18024-F
S8VS-24024-F
3.75 A
Yes
---
120 W
180 W
240 W
5 A
24 V
7.5 A
10 A
---
---
20 A
Peak current 30 A
(200 VAC)
480 W
100 to 240 VAC
---
S8VS-48024
S8VS-48024-F
*1. The output capacity of the S8VS-01505 is 10 W.
*2. The output capacity of the S8VS-03005 is 20 W.
*3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Models with Indication Monitor (Maintenance Forecast Monitor)
Output
voltage
Alarm
UL Class 2
Model number
Model number
Power ratings Input voltage
Output current
2.5 A
output *2
Output standards (screw terminal block) (screwless terminal block)
60 W
---
Sinking
Sinking
Sourcing
Sourcing
Sinking
Sourcing
Sinking
Sourcing
Sinking
Sourcing
Yes
---
S8VS-06024A
S8VS-09024A
S8VS-09024AS
S8VS-09024AP
S8VS-09024APS
S8VS-12024A
S8VS-12024AP
S8VS-18024A
S8VS-18024AP
S8VS-24024A
S8VS-24024AP
S8VS-06024A-F
S8VS-09024A-F
S8VS-09024AS-F
S8VS-09024AP-F
S8VS-09024APS-F
S8VS-12024A-F
S8VS-12024AP-F
S8VS-18024A-F
S8VS-18024AP-F
S8VS-24024A-F
S8VS-24024AP-F
Yes
---
90 W
3.75 A
100 to 240
VAC
Yes
---
(allowable
range: 85 to
264 VAC or 80
to 370 VDC
*1)
120 W
180 W
240 W
5 A
---
24 V
---
7.5 A
10 A
---
---
---
20 A
Peak current 30 A
(200 VAC)
100 to 240
VAC
Sinking/
sourcing
480 W
---
S8VS-48024A
S8VS-48024A-F
*1. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*2. In the Alarm output column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.
Models with Indication Monitor (Total Run Time Monitor)
Output
voltage
Alarm
UL Class 2
Model number
Model number
Power ratings Input voltage
Output current
2.5 A
output *2
Output standards (screw terminal block) (screwless terminal block)
60 W
---
---
Yes
---
S8VS-06024B
S8VS-09024BE
S8VS-09024BES
S8VS-09024B
S8VS-09024BS
S8VS-09024BP
S8VS-09024BPS
S8VS-12024BE
S8VS-12024B
S8VS-12024BP
S8VS-18024BE
S8VS-18024B
S8VS-18024BP
S8VS-24024BE
S8VS-24024B
S8VS-24024BP
S8VS-06024B-F
S8VS-09024BE-F
S8VS-09024BES-F
S8VS-09024B-F
S8VS-09024BS-F
S8VS-09024BP-F
S8VS-09024BPS-F
S8VS-12024BE-F
S8VS-12024B-F
S8VS-12024BP-F
S8VS-18024BE-F
S8VS-18024B-F
S8VS-18024BP-F
S8VS-24024BE-F
S8VS-24024B-F
S8VS-24024BP-F
---
Yes
---
Sinking
Sinking
Sourcing
Sourcing
---
90 W
3.75 A
Yes
---
100 to 240
VAC
Yes
---
(allowable
range: 85 to
264 VAC or 80
to 370 VDC)
*1
120 W
180 W
5 A
Sinking
Sourcing
---
---
24 V
---
---
7.5 A
10 A
Sinking
Sourcing
---
---
---
---
240 W
480 W
Sinking
Sourcing
---
---
20 A
Peak current 30 A
(200 VAC)
100 to 240
VAC
Sinking/
sourcing
---
S8VS-48024B
S8VS-48024B-F
*1. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
*2. In the Alarm output column, “sinking” indicates an emitter COM and “sourcing” indicates a collector COM.
Note: Refer to pages 24 to 25 for the options that available.
3
S8VS
Specifications
Ratings/Characteristics
Power ratings
15 W
12 V
30 W
12 V
Item
Output voltage
5 V
24 V
83% typical
80% typical
5 V
74% typical
74% typical
24 V
85% typical
86% typical
With 100-VAC input 74% typical
With 200-VAC input 73% typical
79% typical
78% typical
81% typical
80% typical
Efficiency
Voltage *1
100 to 240 VAC (allowable range: 85 to 264 VAC, 80 to 370 VDC *5)
Frequency *1
50/60 Hz (47 to 450 Hz)
With 100-VAC input 0.45 A max., 0.34 A typical
0.9 A max., 0.66 A typical
0.6 A max., 0.4 A typical
Current
With 200-VAC input 0.25 A max., 0.22 A typical
Power factor
---
Input
Harmonic current regulation
Conforms to EN61000-3-2
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Leakage current
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Inrush current *2
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
−10% to 15% (with V.ADJ)
60 mV max. 70 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
60 mV max.
60 mV max.
90 mV max.
150 mV max.
Load variation influence
(rated input voltage)
2.0% max. (5 V), 1.5% max. (12 V, 24 V), (with rated input, 0 to 100% load)
Output
Temperature variation influence
0.05%/°C max.
With 100-VAC input 580 ms typical
530 ms typical
360 ms typical
27 ms typical
134 ms typical
600 ms typical
400 ms typical
28 ms typical
134 ms typical
500 ms typical
360 ms typical
31 ms typical
174 ms typical
560 ms typical
380 ms typical
22 ms typical
123 ms typical
560 ms typical
400 ms typical
31 ms typical
140 ms typical
Startup time
(at rated I/O) *2
With 200-VAC input 340 ms typical
With 100-VAC input 39 ms typical
With 200-VAC input 187 ms typical
Output hold time
(at rated I/O) *2
Overload protection *2
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Overvoltage protection *2
Output voltage indication
Yes *4
No
Output current indication
No
Peak-hold current indication
Maintenance forecast monitor indication
No
No
Additional Maintenance forecast monitor output
No
functions
Total run time monitor indication
No
Total run time monitor output
Undervoltage alarm indication
Undervoltage alarm output
Parallel operation
No
Yes (color: red)
No
No
Models with 24-V output: Possible for up to 2 Power Supplies (with external diode)
Models with 5- or 12-V output: Not possible
Series operation
Operating ambient temperature
Storage temperature
Refer to the derating curve in Engineering Data. (with no icing or condensation)
−25 to 65°C
Operating ambient humidity
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
100 MΩ min. (between all outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Output indicator
Other
Conducted
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
Emissions
EMI
Radiated Emissions Conforms to EN61204-3 EN55011 Class B
EMS
Conforms to EN61204-3 high severity levels
UL Listed: UL508 (Listing, Class2 Output: Per 1310)
UL UR: UL60950-1 (Recognition)
Approved standards
cUL: CSA C22.2 No.107.1 (Class2 Output: Per CSA C22.2 No.223)
cUR: CSA C22.2 No.60950-1
EN/VDE: EN50178 (=VDE0160), EN60950-1 (=VDE0805 Teil1)
SEMI
F47-0706 (With 200-VAC input)
Weight
160 g max.
180 g max.
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal
temperature of the Power Supply may result in ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 18 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range. When adjusting
the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
4
S8VS
Power ratings
Type
60 W
90 W
Maintenance
forecast monitor
Total run time
monitor
Maintenance
forecast monitor
Total run time
monitor
Item
Standard
Standard
With 100-VAC input 84% typical
With 200-VAC input 83% typical
83% typical
85% typical
83% typical
84% typical
83% typical
85% typical
Efficiency
Voltage *1
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11)
Frequency *1
50/60 Hz (47 to 450 Hz)
With 100-VAC input 1.7 A max., 1.3 A typical
1.7 A max., 1.3 A typical
2.3 A max., 1.9 A typical 2.3 A max., 1.9 A typical
1.4 A max., 1.0 A typical 1.4 A max., 1.2 A typical
Current
With 200-VAC input 1.0 A max., 0.68 A typical 1.0 A max., 0.78 A typical
Power factor
---
Input
Harmonic current regulation
Conforms to EN61000-3-2
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Leakage current
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Inrush current *2
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
−10% to 15% (with V. ADJ) (The voltage cannot be adjusted for the S8VS-09024@@@S-@.)
70 mV max.
90 mV max.
250 mV max.
150 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence (rated input voltage) 1.5% max. (with rated input, 0 to 100% load)
Temperature variation influence 0.05%/°C max.
Output
With 100-VAC input 620 ms typical
With 200-VAC input 400 ms typical
With 100-VAC input 34 ms typical
With 200-VAC input 158 ms typical
460 ms typical
290 ms typical
33 ms typical
154 ms typical
460 ms typical
300 ms typical
28 ms typical
132 ms typical
660 ms typical
420 ms typical
28 ms typical
136 ms typical
Startup time
(at rated I/O) *2
Output hold time
(at rated I/O) *2
Overload protection *2
105% to 160% of rated load current (101% to 110% of rated load current for the S8VS-09024@@@S-@), inverted L voltage drop, intermittent, automatic reset
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
Maintenance forecast monitor indication
Yes
No
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
No
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
*
5
No
Yes (selectable)
No
Yes (transistor output),
30 VDC max., 50 mA max. *9
Additional Maintenance forecast monitor output
functions
No
No
No
No
Total run time monitor indication *5
Yes (selectable)
No
No
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA max. *9
Total run time monitor output *5
Undervoltage alarm indication *5
Undervoltage alarm output terminals
Parallel operation
No
No
No
Yes (selectable)
Yes (selectable)
Yes (transistor output), 30 VDC max., 50 mA max. *9
Series operation
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25 to 65°C
Operating ambient temperature
Storage temperature
Operating ambient humidity
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA)
Dielectric strength
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
Insulation resistance
Vibration resistance
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
Shock resistance
Output indicator
150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A and based on FCC Class A, Conforms to EN61204-3
EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Conducted
Emissions
Other
EMI
Radiated
Emissions
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A, Conforms to EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B
EMS
Conforms to EN61204-3 high severity levels
UL: UL 508 (Listing)
UL Listed (S8VS-09024@@@S-@ only.): UL 508 (Listing, Class 2
Output: Per UL1310),
UL UR: UL 60950-1 (Recognition),
cUL: CSA C22.2 No.107.1,
cUL (S8VS-09024-@@@S-@ only): CSA C22.2 No.107.1 (Class 2
Output: Per CSA C22.2 No. 223),
cUR: CSA C22.2 No.60950-1,
EN/VDE: EN 50178 (= VDE 0160),
EN 60950-1 (= VDE 0805 Teil 1)
UL: UL 508 (Listing; Class 2 Output: Per UL1310), UL UR: UL
60950-1 (Recognition),
cUL: CSA C22.2 No.107.1 (Class 2 Output: Per CSA C22.2 No.
223),
cUR: CSA C22.2 No.60950-1,
EN/VDE: EN 50178 (= VDE 0160), EN 60950-1
(= VDE 0805 Teil 1)
Approved standards *11
KOSHA S Mark *10
KOSHA S Mark *10
SEMI *11
F47-0706 (With 200-VAC input)
330 g max.
Weight
490 g max.
*1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in
ignition or burning.
*2. For a cold start at 25°C. Refer to Engineering Data on page 18 for details.
*3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than +15% of the voltage adjustment range (by more than +10% for 240-W models with indication monitor).
When adjusting the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged.
*4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.
*5. Displayed on 7-segment LED. (character height: 8 mm)
*6. Resolution of output voltage indication: 0.1 V, Precision of output voltage indication: 2% (percentage of output voltage value, 1 digit)
*7. Resolution of output current indication: 0.1 A; Precision of output current indication: 5% F.S. 1 digit max. (specified by rated output voltage)
*8. Resolution of peak-hold current indication: 0.1 A; Precision of peak-hold current indication: 5% F.S. 1 digit max. (specified by rated output voltage);
Signal width required for peak-hold current: 20 ms
*9. A Type and B Type: Sinking, AP Type and BP Type: Sourcing, BE Type: No alarm output.
*10. S8VS-06024A, S8VS-09024A/AP, S8VS-12024A/AP, S8VS-18024A/AP, and S8VS-24024A/AP only
*11. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
5
S8VS
Power ratings
Type
120 W
180 W
Maintenance
forecast monitor
Total run time
monitor
Maintenance
forecast monitor
Total run time
monitor
Item
Standard
Standard
With 100-VAC input 84% typical
With 200-VAC input 87% typical
83% typical
85% typical
85% typical
88% typical
85% typical
87% typical
Efficiency
Voltage *1
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC *11)
Frequency *1
50/60 Hz (47 to 63 Hz)
With 100-VAC input 1.9 A max., 1.5 A typical
2.9 A max., 2.2 A typical
1.6 A max., 1.1 A typical
Current
1.1 A max.,
With 200-VAC input
1.1 A max., 0.72 A typical
0.71 A typical
Power factor
0.9 min.
Input
Harmonic current regulation
Conforms to EN61000-3-2
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Leakage current
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Inrush current *2
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
−10% to 15% (with V.ADJ)
60 mV max.
130 mV max.
50 mV max.
180 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence
(rated input voltage)
1.5% max. (with rated input, 0 to 100% load)
Output
Temperature variation influence
0.05%/°C max.
With 100-VAC input 550 ms typical
650 ms typical
520 ms typical
56 ms typical
56 ms typical
570 ms typical
470 ms typical
58 ms typical
62 ms typical
580 ms typical
490 ms typical
70 ms typical
70 ms typical
Startup time
(at rated I/O) *2
With 200-VAC input 400 ms typical
With 100-VAC input 52 ms typical
With 200-VAC input 54 ms typical
Output hold time
(at rated I/O) *2
Overload protection *2
105% to 160% of rated load current, inverted L voltage drop, automatic reset
Yes
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
No
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable) No
Maintenance forecast monitor indication *5 No
No
Yes (transistor
output), 30 VDC
max., 50 mA max.
*9
Yes (transistor
output), 30 VDC
max., 50 mA max.
*9
Maintenance forecast monitor output
Total run time monitor indication *5
Total run time monitor output *5
No
No
No
No
No
No
No
No
Additional
functions
Yes (selectable)
Yes (selectable)
Yes (transistor
output), 30 VDC
max., 50 mA max.
*9
Yes (transistor
output), 30 VDC
max., 50 mA max.
*9
Undervoltage alarm indication *5
No
No
No
Yes (selectable)
No
No
Yes (selectable)
Yes (transistor output), 30 VDC max.,
50 mA max. *9
Yes (transistor output), 30 VDC max.,
50 mA max. *9
Undervoltage alarm output terminals
Parallel operation
Series operation
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25 to 65°C
Operating ambient temperature
Storage temperature
Operating ambient humidity
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection
current for models with indication monitor: 20 mA
Dielectric strength
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
Insulation resistance
Vibration resistance
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
Shock resistance
Output indicator
150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Other
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A and based on FCC Class A, Conforms to EN61204-3
EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Conducted
Emissions
EMI
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A, Conforms to EN61204-3 EN55011 Class B *11
Standard models: Conforms to EN61204-3 EN55011 Group 1 Class B
Radiated Emissions
EMS
Conforms to EN61204-3 high severity levels
UL Listed: UL 508 (Listing),
UL UR: UL 60950-1 (Recognition),
cUL: CSA C22.2 No. 107.1,
cUR: CSA C22.2 No. 60950-1,
Approved standards *11
EN/VDE: EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)
KOSHA S Mark *10
SEMI *11
F47-0706 (200-VAC input)
Weight
550 g max.
850 g max.
Note: Refer to page 5 for notes 1 to 11.
6
S8VS
Power ratings
Type
240 W
480 W
Maintenance
forecast monitor
Total run time
monitor
Maintenance
forecast monitor
Total run time
monitor
Item
Standard
Standard
With 100-VAC input 85% typical
With 200-VAC input 88% typical
85% typical
89% typical
Efficiency
Voltage *1
100 to 240 VAC (allowable range: 85 to 264 VAC or 80 to 370 VDC
50/60 Hz (47 to 63 Hz)
*11)
100 to 240 VAC (allowable range: 85 to 264 VAC)
Frequency *1
With 100-VAC input 3.8 A max., 2.9 A typical
7.4 A max., 5.8 A typical
3.9 A max., 2.8 A typical
0.95 min.
Current
With 200-VAC input 2.0 A max., 1.5 A typical
Power factor
0.9 min.
Input
Harmonic current regulation
Conforms to EN61000-3-2
With 100-VAC input 0.5 mA max.
With 200-VAC input 1.0 mA max.
Leakage current
With 100-VAC input 17.5 A max., 14 A typical
With 200-VAC input 35 A max., 28 A typical
Inrush current *2
Voltage adjustment range *3
Ripple noise voltage (at rated I/O)
Input variation influence
−10% to 15% (with V.ADJ)
−10% to 15% (with V.ADJ)
140 mV max.
160 mV max.
310 mV max.
0.5% max. (at 85- to 264-VAC input, 100% load)
Load variation influence
(rated input voltage)
1.5% max. (with rated input, 0 to 100% load)
Output
Temperature variation influence
0.05%/°C max.
With 100-VAC input 540 ms typical
510 ms typical
510 ms typical
46 ms typical
46 ms typical
460 ms typical
340 ms typical
37 ms typical
41 ms typical
Startup time
(at rated I/O) *2
With 200-VAC input 230 ms typical
With 100-VAC input 64 ms typical
With 200-VAC input 64 ms typical
Output hold time
(at rated I/O) *2
Overload protection *2
105% to 160% of rated load current, inverted L voltage drop, automatic reset
Yes
Overvoltage protection *2, *4
Output voltage indication *5
Output current indication *5
Peak-hold current indication *5
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
No
No
No
Yes (selectable) *6
Yes (selectable) *7
Yes (selectable) *8
Yes (selectable)
Maintenance forecast monitor indication *5 No
No
No
Yes (transistor output),
30 VDC max., 50 mA
max. *9
Yes (transistor
output), 30 VDC
max., 50 mA max.
Maintenance forecast monitor output
Total run time monitor indication *5
Total run time monitor output *5
No
No
No
No
No
Additional
functions
Yes (selectable)
No
No
Yes (selectable)
Yes (transistor output),
30 VDC max., 50 mA
max.
Yes (transistor output),
30 VDC max., 50 mA
max. *9
*9
Undervoltage alarm indication *5
No
No
No
Yes (selectable)
No
No
Yes (selectable)
Yes (transistor output), 30 VDC max.,
50 mA max. *9
Yes (transistor output), 30 VDC max.,
50 mA max. *9
Undervoltage alarm output terminals
Parallel operation
Series operation
Yes for up to 2 Power Supplies (with external diode)
Refer to the derating curve in . (with no icing or condensation)
−25 to 65°C
Operating ambient temperature
Storage temperature
Operating ambient humidity
25% to 85% (Storage humidity: 25% to 90%)
3.0 kVAC for 1 min. (between all inputs and outputs/alarm outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)
Dielectric strength
1.0 kVAC for 1 min. (between all outputs/ alarm outputs and PE terminals; detection current for standard 240-W and 480-W
models: 30 mA, detection current for 240-W models with indication monitor: 20 mA)
500 VAC for 1 min. (between all outputs and alarm outputs; detection current: 20 mA)
Insulation resistance
Vibration resistance
100 MΩ min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 VDC
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions: 240 W
10 to 150 Hz, 0.35-mm single amplitude (3 G max.) for 80 min each in X, Y, and Z directions: 480 W
Shock resistance
Output indicator
150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Yes (color: green)
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A and based on FCC Class A, Conforms to
EN61204-3 EN55011 Class B *11
Conforms to EN61204-3 EN55011 Class A and based on FCC
Class A
Conforms to EN61204-3 EN55011 Class B *11
Other
Conducted
Emissions
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B and based on FCC Class A
EMI
Models with indication monitor: Conforms to EN61204-3
EN55011 Class A, Conforms to EN61204-3 EN55011 Class B
Conforms to EN61204-3 EN55011 Class A
Conforms to EN61204-3 EN55011 Class B *11
Radiated Emissions *11
Standard models: Conforms to EN61204-3 EN55011 Group 1
Class B
EMS
Conforms to EN61204-3 high severity levels
UL Listed: UL 508 (Listing),
UL UR: UL 60950-1 (Recognition),
cUL: CSA C22.2 No.107.1,
cUR: CSA C22.2 No. 60950-1,
Approved standards *11
EN/VDE: EN 50178 (=VDE 0160), EN 60950-1 (=VDE 0805 Teil 1)
KOSHA S Mark *10
SEMI *11
F47-0706 (200-VAC input)
1,150 g max.
Weight
1,700 g max.
Note: Refer to page 5 for notes 1 to 11.
7
S8VS
Connections
Block Diagrams
S8VS-015@@ (15 W)
Undervoltage
indicator
Fuse:
3.15 A
AC (L)
+V
INPUT
DC output
−V
Noise filter
AC (N)
Inrush
current
protection
Rectifier/
smoothing
circuit
Smoothing
circuit
Rectifier
Drive
control
circuit
Voltage
detection circuit
Overcurrent
detection circuit
Overvoltage
detection circuit
Photocoupler
S8VS-030@@ (30 W)
Undervoltage
indicator
Fuse:
4.0 A
AC (L)
+V
INPUT
DC output
−V
Noise filter
AC (N)
Inrush
current
protection
Rectifier/
smoothing
circuit
Smoothing
circuit
Rectifier
Drive
control
circuit
Voltage
detection circuit
Overcurrent
detection circuit
Overvoltage
detection circuit
Photocoupler
8
S8VS
S8VS-06024A-@ (60 W)
S8VS-06024B-@ (60 W)
Display circuit
Switch
Arithmetic
operation circuit
Fuse
6.3 A
Rectifier/smoothing circuit
+V
AC (L)
INPUT
Noise filter
DC OUTPUT
−V
AC (N)
Inrush
current
Rectifier/
smoothing
circuit
Rectifier
Rectifier/smoothing circuit
protection
circuit
Drive control
circuit
Overcurrent
circuit
Current detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
S8VS-06024-@ (60 W)
Fuse
6.3 A
AC (L)
+V
INPUT
Noise filter
DC OUTPUT
AC (N)
−V
Inrush current
protection
circuit
Smooth-
ing
Rectifier/smoothing circuit
Rectifier
circuit
Drive control
circuit
Overcurrent
circuit
Current detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
9
S8VS
S8VS-09024A@-@ (90 W)
S8VS-09024B@-@ (90 W)
S8VS-09024BE-@ (90 W)
S8VS-09024A@S-@ (90 W)
S8VS-09024B@S-@ (90 W)
S8VS-09024BES-@ (90 W)
Sinking type
(S8VS-09024A-@, S8VS-09024B-@,
S8VS-09024AS-@, S8VS-09024BS-@)
Sourcing type
(S8VS-09024AP-@, S8VS-09024BP-@,
S8VS-09024APS-@, S8VS-09024BPS-@)
Type with no alarm output
(S8VS-09024BE-@, S8VS-09024BES-@)
Display circuit
Switch
Alarm
DC Low
Arithmetic
operation circuit
Yrs/kh
Common
Rectifier/smoothing circuit
Photocoupler
Fuse 8.0 A
AC (L)
+V
INPUT
DC OUTPUT
Noise filter
AC (N)
−V
Rectifier/
smoothing
circuit
Inrush current
protection
circuit
Rectifier/smoothing circuit
Rectifier
Drive control
circuit
Overcurrent
circuit
Current detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
S8VS-09024-@ (90 W)
S8VS-09024S-@ (90 W)
Fuse
8.0 A
AC (L)
+V
INPUT
Noise filter
DC OUTPUT
AC (N)
−V
Inrush current
protection
circuit
Smooth-
Rectifier/smoothing circuit
Rectifier
ing
circuit
Drive control
circuit
Overcurrent
circuit
Current detection
circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
10
S8VS
S8VS-12024A@-@ (120 W)
S8VS-12024B@-@ (120 W)
S8VS-12024BE-@ (120 W)
Sinking type
(S8VS-12024A-@, S8VS-12024B-@)
Sourcing type
(S8VS-12024AP-@ S8VS-12024BP-@)
Type with no alarm output
(S8VS-12024BE-@)
Display circuit
Switch
Alarm
DC Low
Arithmetic
operation circuit
Yrs/kh
Common
Rectifier/smoothing circuit
Photocoupler
Fuse 5.0 A
AC (L)
+V
INPUT
AC (N)
DC OUTPUT
Noise filter
−V
Rectifier Harmonic current
suppression circuit
Inrush current Smoothing
protection circuit
Rectifier/smoothing circuit
(Power factor improvement) circuit
Drive control
circuit
Voltage
detection circuit
Overcurrent
circuit
Overvoltage
detection circuit
Photocoupler
f
S8VS-12024-@ (120 W)
Fuse
5.0 A
AC (L)
+V
INPUT
DC OUTPUT
Noise filter
AC (N)
−V
Rectifier
Harmonic current
Inrush current Smoothing
Rectifier/smoothing circuit
suppression circuit
circuit
protection
circuit
(Power factor improvement)
Drive control
circuit
Voltage
detection circuit
Overcurrent
detection circuit
Overvoltage
detection circuit
Photocoupler
11
S8VS
S8VS-18024A@-@ (180 W)
S8VS-18024B@-@ (180 W)
S8VS-18024BE-@ (180 W)
Sinking type
(S8VS-18024A-@, S8VS-18024B-@)
Sourcing type
(S8VS-18024AP-@, S8VS-18024BP-@)
Type with no alarm output
(S8VS-18024BE-@)
Display circuit
Switch
Alarm
DC Low
Arithmetic
operation circuit
Yrs/kh
Common
Rectifier/smoothing circuit
Photocoupler
Fuse 6.3 A
AC (L)
+V
DC OUTPUT
INPUT
AC (N)
Noise filter
−V
Rectifier/smoothing circuit
Rectifier Harmonic current
suppression circuit
Inrush current Smoothing
protection
circuit
(Power factor improvement) circuit
Drive control
circuit
Overcurrent
detection circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
S8VS-18024-@ (180 W)
Fuse
6.3 A
AC (L)
+V
INPUT
DC OUTPUT
Noise filter
AC (N)
−V
Rectifier
Harmonic current
Smoothing
circuit
Inrush current
protection
circuit
Rectifier/smoothing circuit
suppression circuit
(Power factor improvement)
Drive control
circuit
Overcurrent
detection circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
12
S8VS
S8VS-24024A@-@ (240 W)
S8VS-24024B@-@ (240 W)
S8VS-24024BE-@ (240 W)
Sinking type
(S8VS-24024A-@, S8VS-24024B-@)
Sourcing type
(S8VS-24024AP-@, S8VS-24024BP-@)
Type with no alarm output
(S8VS-24024BE-@)
Display circuit
Switch
Alarm
DC Low
Arithmetic
operation circuit
Yrs/kh
Common
Rectifier/smoothing circuit
Photocoupler
+V
+V
Fuse 8.0 A
AC (L)
INPUT
AC (N)
DC OUTPUT
Noise filter
−V
−V
Rectifier/smoothing circuit
Rectifier Harmonic current
suppression circuit
Inrush current Smoothing
protection
circuit
(Power factor improvement) circuit
Drive control
circuit
Overcurrent
Voltage
detection circuit
detection circuit
Overvoltage
detection circuit
Photocoupler
S8VS-24024-@ (240 W)
Fuse
8.0 A
AC (L)
+V
INPUT
DC OUTPUT
Noise filter
AC (N)
−V
Rectifier Harmonic current
Inrush current
Smoothing
circuit
Rectifier/smoothing circuit
suppression circuit
protection
(Power factor improvement) circuit
Drive control
circuit
Overcurrent
detection circuit
Voltage
detection circuit
Overvoltage
detection circuit
Photocoupler
13
S8VS
S8VS-48024-@ (480 W)
S8VS-48024A-@ (480 W)
S8VS-48024B-@ (480 W)
+V
+V
+V
Fuse 12A
AC (L)
INPUT
Noise filter
DC OUTPUT
−V
−V
−V
AC (N)
Inrush
Rectifier/
smoothing circuit
Rectifier Harmonic current
suppression
Smoothing
circuit
current
protection
circuit
(power factor
improvement)
Overvoltage
detection circuit
Control
circuit
Drive circuit
Voltage
detection circuit
Arithmetic
operation
circuit
Current
detection circuit
Overcurrent
circuit
Rectifier/
smoothing
circuit
Auxiliary power
supply circuit
S8VS-48024A/B
DC LOW
Yrs/kh
Display
circuit
Switch
Photocoupler
Alarm Output Connections
90, 120, 180, and 240 W (Sinking type)
11 Undervoltage
Undervoltage
12 Maintenance
forecast time or
total run time
Maintenance
forecast time or
total run time
13 Common
90, 120, 180, and 240 W (Sourcing type)
13 Common
Undervoltage
11 Undervoltage
Maintenance
forecast time or
total run time
12 Maintenance
forecast time or
total run time
480 W
12
Undervoltage
Undervoltage
11
14
Maintenance
forecast time or
total run time
Maintenance
forecast time or
total run time
13
14
S8VS
Construction and Nomenclature
Nomenclature
15-W, 30-W Models
S8VS-015@@/S8VS-030@@
1
No.
1
Name
Function
Input terminals (L), (N)
Connect the input lines to these terminals. *1
Connect the ground line to this terminal. *2
Connect the load lines to these terminals.
Lights while a direct current (DC) output is ON.
2
Protective Earth terminal (PE)
DC Output terminals (−V), (+V)
Output indicator (DC ON: Green)
2
4
3
4
5
Undervoltage indicator (DC LOW: Red) Lights when a drop is detected in the output voltage.
Output voltage adjuster (V.ADJ) Use to adjust the voltage.
5
6
6
*1. The fuse is located on the (L) side. For a DC input, connect the positive voltage to the L terminal.
*2. This is the protective earth terminal specified in the safety standards. Always ground this terminal.
3
Note: The S8VS-01505 is shown above.
15
S8VS
Nomenclature
No.
Name
Function
60-W Models
Input terminals
(L), (N)
Connect the input lines to these
1
Standard Model
S8VS-06024
Models with Indication Monitor
S8VS-06024@
terminals. *1
Protective Earth
terminal (PE)
Connect the ground line to this
2
3
4
5
6
terminal. *2
1
2
1
2
DC Output terminals
(−V), (+V)
Connect the load lines to these
terminals.
Output indicator
(DC ON: Green)
Lights while a direct current (DC)
output is ON.
6
7
8
Output voltage
adjuster (V.ADJ)
Use to adjust the voltage. *3
4
5
4
5
Indicates the measurement or set
value.
Main display (Red) *4
3
33
Lights up when the output voltage is
indicated. Blinks during setup of
undervoltage alarm value.
V
A
Note: The S8VS-06024A is shown above.
90-W/120-W Models
Lights up during indication of output
current.
Standard Models
S8VS-09024/S8VS-0924S/
S8VS-12024
Models with Indication Monitor
S8VS-09024@@@/
S8VS-09024@@@S/S8VS-12024@@@
Lights up during indication of peak
hold current.
Apk
Operation
7
indicator
(Orange) *4
Lights up during indication of
maintenance forecast monitor.
Yrs Blinks during setup of maintenance
forecast monitor setting. (S8VS-
@@@24A@@)
1
2
1
2
Lights up during indication of total
6
7
run time monitor. Blinks during setup
8
9
kh
10
of total run time monitor. (S8VS-
@@@24B@@)
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
4
5
12
4
5
8
9
Mode Key *4
Up Key *5
Use the Up Key to change to the
setting mode or to increase the set
value.
3
3
1113
Note: The S8VS-12024A is shown above.
180-W Models
Use the Down Key to change to the
setting mode or to decrease the set
value.
10 Down Key *5
Undervoltage
Standard Model
S8VS-18024
Models with Indication Monitor
S8VS-18024@@@
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
2
1
2
1
output
11
terminal (DC
Low)
Maintenance
Forecast
output
6
7
Output when the set value for
maintenance is reached (transistor
Alarm
10
8
9
terminal(Yrs) OFF).
outputs
*7
12 *5, *6
Totalruntime
4
5
4
5
12
output
Output when the set value for total
terminal (kh) run time is reached (transistor OFF).
*8
3
11 13 3
Common
terminal
Common terminal for terminals 11
and 12.
13
Note: The S8VS-18024A is shown above.
*1. The fuse is located on the (L) side. For a DC input, connect the
positive voltage to the L terminal.
240-W Models
Standard Model
S8VS-24024
Models with Indication Monitor
S8VS-24024@@@
*2. This is the protective earth terminal specified in the safety
standards. Always ground this terminal.
*3. The output voltage cannot be adjusted for the
S8VS-09024@@@S.
*4. S8VS-@@@24A@@/B@@/BE@ only.
1
2
1
2
*5. S8VS-@@@24A@@/B@@ only (except the S8VS-06024@).
*6. Both sinking and sourcing outputs are available.
*7. S8VS-@@@24A@@ only (excluding S8VS-06024A).
*8. S8VS-@@@24B@@ only (excluding S8VS-06024B).
6
7
10
8
9
4
5
12
4
5
3
1113 3
Note: The S8VS-24024A is shown above.
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
16
S8VS
No.
Name
Function
480-W Models
AC Input terminals
(L), (N)
Connect the input lines to these
Standard Model
S8VS-48024
1
terminals. *1
Protective Earth
terminal (PE)
Connect the ground line to this
2
3
4
5
6
terminal. *2
1
2
DC Output terminals
(−V), (+V)
Connect the load lines to these
terminals.
Output indicator
(DC ON: Green)
Lights while a direct current (DC)
output is ON.
Output voltage adjuster
(V.ADJ)
Use to adjust the voltage.
Indicates the measurement or set
value.
Main display (Red) *3
Lights up when the output voltage is
indicated. Blinks during setup of
undervoltage alarm value.
4
5
V
A
3
Lights up during indication of output
current.
Models with Indication Monitor
S8VS-48024@
Lights up during indication of peak
hold current.
Apk
Operation
indicator
Lights up during indication of
maintenance forecast monitor.
Yrs Blinks during setup of maintenance
forecast monitor setting. (S8VS-
48024A)
7
1
2
(Orange) *3
6
Lights up during indication of total
7
run time monitor. Blinks during setup
of total run time monitor. (S8VS-
kh
48024B)
9
Use the Mode Key to change the
indicated parameter or reset the
peak hold current value.
10
8
8
9
Mode Key *3
Up Key *3
4
5
16
15
Use the Up Key to change to the
setting mode or to increase the set
value.
3
14 13 12 11
Use the Down Key to change to the
setting mode or to decrease the set
value.
Note: The illustration shows the S8VS-48024A model.
10 Down Key *3
Undervoltage
* The terminal arrangement is the same for models with screwless
terminal blocks and standard models.
output terminal
(DC Low)
11
Output when a drop is detected in
the output voltage (voltage drop =
transistor OFF).
(Emitter side)
Undervoltage
output terminal
(DC Low)
12
(Collector side)
Maintenance
Forecast
Output when the set value for
output terminal maintenance is reached (transistor
(Yrs) *4
OFF).
Alarm
outputs
*3
(Emitter side)
13
Total run time
output terminal Output when the set value for total
(kh) *5
(Emitter side)
run time is reached (transistor OFF).
Maintenance
Forecast
Output when the set value for
output terminal maintenance is reached (transistor
(Yrs) *4
(Collector side)
OFF).
14
Total run time
output terminal Output when the set value for total
(kh) *5
(Collector side)
run time is reached (transistor OFF).
15,
16
NC (Not connected)
*1. The fuse is located on the (L) side. It is NOT user replaceable.
*2. This is the protective earth terminal specified in the safety standards.
Always ground this terminal.
*3. S8VS-48024A/B only.
*4. S8VS-48024A only.
*5. S8VS-48024B only.
17
S8VS
Engineering Data
Derating Curve
15 W <S8VS-015@@>
120
60, 90, 120, 180, 240, and 480 W
120
1
100
100
80
1
*
80
60
40
*1
*2
60
40
*3
20
0
20
0
−20 −10
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
−20 −10
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
* Using side mounting bracket for right-side mounting (excluding
240-W models). UL certification conditions do not apply if the side
mounting bracket is used.
Note: 1. Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply in areas outside the derating
curve (i.e., the area shown by shading A in the above
graph).
*1 Standard mounting
*2 Face-up mounting
*3 Horizontal mounting
30 W <S8VS-03005/S8VS-03012>
120
2. If there is a derating problem, use forced air-cooling.
3. When using a 480-W model at an input voltage of 95 VAC
or less, derate the load by at least 80%.
4. DC Inputs
100
1
If the input voltage is less than 100 VDC, reduce the load
given in the above derating curve by at least the following
factor.
60-W models: 0.9 max.
90-W models: 0.85 max.
80
60
40
*1
*2
120-W/180-W/240-W models: 0.8 max.
20
0
−20 −10
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
*1 Standard mounting
*2 Face-up mounting/Horizontal mounting
30 W <S8VS-03024>
120
100
1
80
60
40
*1
*2
20
0
−20 −10
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
*1 Standard mounting
*2 Face-up mounting/Horizontal mounting
Note: 1. Internal parts may occasionally deteriorate or be damaged.
Do not use the Power Supply in areas outside the derating
curve (i.e., the area shown by shading A in the above
graph).
2. If there is a derating problem, use forced air-cooling.
3. Provide a space of at least 20 mm when using standard
mounting and horizontal mounting. If 20 mm is not available,
make sure that the space is at least 10 mm. In this case,
reduce the corresponding derating curve by 5°C.
4. DC Inputs
If the input voltage is less than 100 VDC, reduce the load
given in the above derating curve by at least the following
factor.
S8VS-03005: 0.7 max.
S8VS-03012/03024: 0.85 max.
18
S8VS
Mounting
15 and 30 W
Overload Protection
The load and the power supply are automatically protected from
overcurrent damage by this function.
Face-up mounting with DIN rail
Overload protection is activated if the output current rises above
105% of the rated current.
Standard mounting with DIN rail
When the output current returns within the rated range overload
protection is automatically cleared.
15-W/30-W Models
60-W/90-W Models
Face-up mounting with S82Y-VS30P
Standard mounting with S82Y-VS30P
Note: The Side-mounting Bracket can be mounted from either side.
Intermittent
operation
Intermittent operation
0
50
100
0
50
100
Output current (%)
Output current (%)
The values shown in the above diagrams are for reference only.
120-W/180-W/240-W/480-W Models
Horizontal mounting with S82Y-VS30P*
S82Y-VS30P
Side with label
0
50
100
Output current (%)
The values shown in the above diagrams are for reference only.
Note: 1. Improper mounting will interfere with heat dissipation and
may occasionally result in deterioration or damage of
internal parts. Use the Product within the derating curve for
the mounting direction that is used. Do not use the Power
Supply mounted in any way not shown above.
Note: 1. Internal parts may occasionally deteriorate or be damaged
if a short-circuited or overcurrent state continues during
operation.
2. Internal parts may possibly deteriorate or be damaged if the
Power Supply is used for applications with frequent inrush
current or overloading at the load end. Do not use the Power
Supply for such applications.
2. Use a mounting bracket (S82Y-VS30P, sold separately)
when the Product is mounted horizontally.
3. Heat dissipation will be adversely affected. When the
Product is mounted facing horizontally, always place the
side with the label facing horizontally.
Peak Output Current (S8VS-48024@ only)
The peak current must satisfy the following conditions.
Input voltage range: 200 to 240 VAC
Peak current value: 30 A max.
4. Use PFP-M End Plates on the top and bottom of the Power
Supply when mounting horizontally on a DIN rail.
Peak current pulse width: 2 s max.
Cycle: 60 s min.
60, 90, 120, 180, 240, and 480 W
Note: 1. Two seconds after the peak current is reached, the peak
current limiting function operates to stop the peak current
flow.
Upper
Upper
Correct
Incorrect
2. It takes 60 seconds for the peak current to be able to flow
again.
3. The peak current limiting function prevents the peak current
from flowing at 100 to 120 VAC.
Peak current limit
Peak current
condition
60 s min.
Standard mounting
Face-up mounting
2 s
Note: Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts.
It may also result in failure of the maintenance forecast monitor
function. Use the standard mounting method only.
Overcurrent
protection point
Output current
0 A
19
S8VS
Overvoltage Protection
Undervoltage Alarm Function (Indication and
Output) (S8VS-@@@24A@@/S8VS-@@@24B@@/
S8VS-@@@24BE@ Only)
Consider the possibility of an overvoltage and design the system so
that the load will not be subjected to an excessive voltage even if the
feedback circuit in the Power Supply fails. If an excessive voltage that
is approximately 130% of the rated voltage (but approximately 110%
of the rated voltage for the S8VS-09024@@@S) or more is output, the
output voltage is shut OFF. Reset the input power by turning it OFF
for at least three minutes and then turning it back ON again.
When output voltage drop is detected, an alarm (a01) and lowest
output voltage value are indicated alternately. The preset value of
detection voltage can be changed in the setting mode.
(From 18.5 to 27.5 V in 0.1-V steps. The value is fixed at 20.0 V for
the S8VS-06024A/S8VS-06024B.)
Further, an output (undervoltage output terminal (DC LOW)) to an
external device is given from the transistor to notify of the error
(excluding S8VS-06024A/S8VS-06024B/S8VS-@@@24BE@).
(Output voltage drop = OFF, i.e., no continuity at the undervoltage
output terminal (DC LOW).)
Example: Outputting an Alarm When the Voltage Output by the
S8VS-09024A@@ Drops to the Set Value (19.0 V) or Lower
Overvoltage protection
operating
+30%
(approx.)
+15%
Variable range
Rated output
:
voltage
In the case that the
output voltage drops
−10%
below the set value (19.0 V)
and an alarm is issued
Note: 1. Operation begins after about three seconds since the AC
power is supplied.
2. The alarm is not indicated in the setting mode.
0 V
3. Press the
(Mode Key (8)) after the output voltage is
The values shown in the above diagram is for reference only.
restored, to reset alarm indication.
4. The undervoltage alarm function may also operate when an
interruption in AC input is not restored within 20 ms.
5. The undervoltage alarm function monitors the output
terminal voltage of the Power Supply. To check the voltage
accurately, measure the voltage at the load end.
Note: Do not turn ON the power again until the cause of the
overvoltage has been removed.
Inrush Current, Startup Time, Output Hold Time
AC input
Input ON
Input OFF
AC input
voltage
Detection value
of Undervoltage
alarm
Output
voltage
Inrush current on input application
Undervoltage
output
AC input
current
Main display
Operation
mode
Lowest value of
output voltage
Voltage indication
96.5%
90%
Note: Operation begins after about three seconds since the AC
power is supplied.
Output
voltage
Hold time
(20 ms min.)
Startup time (1,000 ms max.)
Undervoltage Alarm Indication
LED (DC LOW: red) lights to warn of output voltage drop.
Detection voltage is set to approx. 80% (75 to 90%) of the rated output
voltage.
Note: This function monitors the voltage at the power supply output
terminals. To check actual voltage, measure voltage on the
load side.
20
S8VS
Dimensions
Power Supplies with Screw Terminal Blocks
Note: All units are in millimeters unless otherwise indicated.
S8VS-015@@ (15 W)
S8VS-030@@ (30 W)
Five, M3.5 terminal
screws with square 10.4
washers
8
4.8
(Sliding: 10 max.)
35.2
85
4
4.8
10.2
(Sliding: 10 max.)
96.4
Rail stopper
22.5
Note: The illustration is the S8VS-03024 model.
Five, M4 terminal screws
with square washers
S8VS-06024 (60 W)
S8VS-06024A (60 W)
11.2
10
7
97.1
S8VS-06024B (60 W)
35.4
95
74
1
40
4.5
(Sliding: 15 max.)
108.3
Rail stopper
Note: The illustration is the S8VS-06024A model.
S8VS-09024 (90 W) /S8VS-09024S (90 W) /S8VS-12024 (120 W)
S8VS-09024A@ (90 W) /S8VS-09024A@S (90 W) /S8VS-12024A@ (120 W)
S8VS-09024B@ (90 W) /S8VS-09024B@S (90 W) /S8VS-12024B@ (120 W)
S8VS-09024BE (90 W) /S8VS-09024BES (90 W) /S8VS-12024BE (120 W)
Five, M4 terminal screws
with square washers
10
10.9
7
110.3
115
94
35.4
1
50
4.5
121.2
(Sliding: 15 max.)
Rail stopper
Screwless block (2.5-mm pitches)
Note: The illustration is the S8VS-12024A model.
Seven, M4 terminal screws
with square washers
S8VS-18024 (180 W)
8.7
10
7
S8VS-18024A@ (180 W)
S8VS-18024B@ (180 W)
S8VS-18024BE (180 W)
116.6
35.4
94
115
1
75
4.5
125.3
(Sliding: 15 max.)
Rail stopper
Screwless block (2.5-mm pitches)
Note: The illustration is the S8VS-18024A model.
21
S8VS
Seven, M4 terminal screws
with square washers
S8VS-24024 (240 W)
S8VS-24024A@ (240 W)
S8VS-24024B@ (240 W)
S8VS-24024BE (240 W)
100
7
7.6
117.6
94
35.4
115
10
1
4.5 (Sliding: 15 max.)
50
125.2
Rail stopper
Rail stopper
Screwless block (2.5-mm pitches)
Note: The illustration shows the S8VS-24024A model.
Nine, M4 terminal screws with square washers
S8VS-48024 (480 W)
S8VS-48024A (480 W)
S8VS-48024B (480 W)
127.2
123.8
150
7
115
115
93
35.4
10
70
4.5 (Sliding: 15 max.)
Rail stopper
Rail stopper
Screwless block (2.5-mm pitches)
Note: The illustration shows the S8VS-48024A model.
Power Supplies with Screwless Terminal Blocks
S8VS-06024-F (60 W)
S8VS-06024A-F (60 W)
10.2
97.1
10
S8VS-06024B-F (60 W)
77.4
95
35.4
1
40
Rail stopper
4.5 (Sliding: 15 max.)
107.3
Note: The illustration shows the S8VS-06024-F model.
S8VS-09024-F (90 W) /S8VS-09024S-F (90 W) /S8VS-12024-F (120 W)
S8VS-09024A@-F (90 W) /S8VS-09024A@S-F (90 W ) /S8VS-12024A@-F (120 W)
S8VS-09024B@-F (90 W) /S8VS-09024B@S-F (90 W) /S8VS-12024B@-F (120 W)
S8VS-09024BE-F (90 W) /S8VS-09024BES-F (90 W) /S8VS-12024BE-F (120 W)
10
10
110.3
35.4
97.3
115
1
50
4.5 (Sliding: 15 max.)
120.3
Rail stopper
Note: The illustration shows the S8VS-12024-F model.
22
S8VS
S8VS-18024-F (180 W)
7.7
10
116.6
S8VS-18024A@-F (180 W)
S8VS-18024B@-F (180 W)
S8VS-18024BE-F (180 W)
35.4
97.3
115
1
75
Rail stopper
4.5 (Sliding: 15 max.)
124.3
Note: The illustration shows the S8VS-18024-F model.
S8VS-24024-F (240 W)
100
6.7
10
117.6
S8VS-24024A@-F (240 W)
S8VS-24024B@-F (240 W)
S8VS-24024BE-F (240 W)
35.4
97.3
115
10
1
4.5 (Sliding: 15 max.)
Rail stopper
124.3
50
Rail stopper
Note: The illustration shows the S8VS-24024-F model.
S8VS-48024-F (480 W)
S8VS-48024A-F (480 W)
S8VS-48024B-F (480 W)
127.2
122.9
150
96.3
35.4
115
10
4.5 (Sliding: 15 max.)
Rail stopper
70
Rail stopper
Note: The illustration shows the S8VS-48024-F model.
23
S8VS
DIN Rail (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
PFP-100N
PFP-50N
Mounting Rail (Material: Aluminum)
0.15
7.3
4.5
0.3
0.15
27
35
15 25
10
25
25
25
10
15(5) *
* Values in parentheses are for the PFP-50N.
1
1,000 (500) *
PFP-100N2
Mounting Rail (Material: Aluminum)
16
4.5
0.3
35
27 24
29.2
1.5
15 25
10
25
25
25 15
10
1
1,000
PFP-M
End Plate
10
6.2
1.8
M4×8 pan-
head screw
1
35.5
50
35.5
1.8
11.5
1.3
4.8
10
M4 spring washer
Note: If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from
aluminum abrasion.
Terminal Block Cover (Order Separately)
Terminal Block Cover model
Applicable models and locations
S8VS-15W
S8VS-30W
S82Y-VS-C2P-S
S8VS-60W input side
S8VS-90W input side
S8VS-120W input side
S8VS-180W input side
S8VS-240W input side
S8VS-480W input/output side
S82Y-VS-C3P
S8VS-60W output side
S8VS-90W output side
S8VS-120W output side
S82Y-VS-C2P-M
S82Y-VS-C4P
S8VS-180W output side
S8VS-240W output side
24
S8VS
Mounting Brackets
Name
Model
Side-mounting Bracket (for 15- and 30-W models)
Side-mounting Bracket (for 60-, 90-, and 120-W models)
Side-mounting Bracket (for 180-W models)
S82Y-VS30P
S82Y-VS10S
S82Y-VS15S
S82Y-VS20S
S82Y-VS10F
Side-mounting Bracket (for 240-W models)
Front-mounting Bracket (for 60-, 90-, 120-, 180-, and 240-W models) *
Note: Brackets cannot be used for 480-W models.
* Two required to mount a 240-W model.
Type
Model
Dimensions
Appearance
0.5
7.1
0.1
109.4
3.5 dia.
85.4
28
15
34
3.5
Side-mounting Bracket
(For 15-, 30-W models)
S82Y-VS30P
22.5
15
15
93.6
t = 0.8
Left-side mounting Right-side mounting
0.1
4.5 dia.
0.1
60
80
Side-mounting Bracket
(For 60-, 90-, 120-W
models)
S82Y-VS10S
0.1
55
35
13
64
t = 2.0
Left-side mounting
4.5 dia. 0.1
60 0.1
80
Side-mounting Bracket
(For 180-W models)
S82Y-VS15S
55 0.1
78
47.5
89
t = 2.0
*Right-side mounting also possible.
Left-side mounting
0.1
4.5 dia.
80
Side-mounting Bracket
(For 240-W models)
S82Y-VS20S
0.1
13
55
78
60
114
t = 2.0
*Right-side mounting also possible.
(For 60-, 90-, 120-,
180-W types)
(For 240-W type)
41
4.5 dia. 0.1
Front-mounting Bracket
(For 60-, 90-, 120-, 180-,
and 240-W models)
S82Y-VS10F
35 0.1
7.3
10
40
50
*Use two S82Y-VS10F
brackets for the 240-W type.
25
S8VS
Display and Alarm Output Functions and Operating Procedures
S8VS-@@@24A@@ models (with display monitor) can display the output voltage, output current, peak hold current, or maintenance forecast
monitor time. S8VS-@@@24B@@/S8VS-@@@24BE@ models (with display monitor) can display the output voltage, output current, peak hold
current, or total run time.
Mode Change
Power-ON
Model indication
Operation mode
Press and hold
Up key U or Down Key D
for three seconds or more.
Press Mode key
hold for three seconds or more.
Or no key operation for 30 seconds or more.
and
Setting mode
Note: No setting mode is provided for the S8VS-06024@.
Operation Mode
Various states of the Power Supply are indicated.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Models with Total Run Time Monitor (S8VS-@@@24B@@/
S8VS-@@@24BE@)
Output voltage
Output voltage
(Voltage output by Power Supply is
monitored and displayed.)
(Voltage output by Power Supply is
monitored and displayed.)
Output current
Output current
(Current output by Power Supply is
monitored and displayed.)
(Current output by Power Supply is
monitored and displayed.)
Peak hold current (See note 1.)
(Maximum current output by Power Supply is
recorded and displayed.)
Peak hold current
(Maximum current output by Power Supply is
recorded and displayed.)
Maintenance forecast monitor
Total run time monitor
Note: 1. The peak hold current starts measuring the current 3 seconds after the Power Supply is started. Inrush current is thus not measured.
2. For the factory setting, the output voltage will be displayed when the power supply is first turned ON. Thereafter, the output voltage will
be indicated in the same display when shutting down.
Setting Mode (Except for S8VS-06024@)
Set various parameters of the Power Supply.
Models with Maintenance Forecast Monitor (S8VS-@@@24A@@)
Models with Total Run Time Monitor (S8VS-@@@24B@@/S8VS-@@@24BE@)
Operation Mode
Operation Mode
Press 3 seconds or more or no key
pressed for 30 seconds or more.
Press 3 seconds or more or no key
pressed for 30 seconds or more.
or
o r
Press 3 seconds
or more.
Press 3 seconds
or more.
*
18.5 to 20.0 to 27.5 (V)
*
/
/
/
Undervoltage
detected
Undervoltage
detected
18.5 to 20.0 to 27.5 (V)
0.1-V steps
0.1-V steps
*
*
/
Maintenance
forecast
Total run
time
0.0 to 0.5 to 5.0 (y)
1 to 50 to 150 ( × 1000 h)
0.5-year steps
1,000-hour steps
* Factory settings are in reverse
type.
* Factory settings are in
reverse type.
Note: 1. Press and hold the (9) Up Key U or (10) Down Key D for two seconds or more to increase or decrease the value rapidly.
2. The S8VS-06024@ is not provided with the setting mode and its parameters are fixed at the shipment setting.
26
S8VS
Peak Hold Current Reset
The peak value of the output current (i.e., the peak hold current) can
Multiple Alarms
When two or more different alarms occur at the same time
be reset on the display.
Operation
Mode
Operation mode
Key Press 3 seconds or more.
Undervoltage
alarm
Reset
The indication shifts
(See note.)
(See note.)
alternately in the direction
of the arrow every 2 s.
2 seconds (Peak hold current will be displayed
Maintenance
forecast
monitor
2 seconds after it is reset.)
Peak hold current
value measurement
starts
Note: The peak hold current value is not reset in the setting mode.
Undervoltage Alarm Indication
This indicator lights when the output voltage lowers.
* When undervoltage alarm is indicated: Press
load indication
Key → output
When the maintenance forecast monitor or overheat alarm is
indicated: Press
Note: 1. The above displays are for models with a maintenance
forecast monitor (S8VS-@@@24A@@).
Key → undervoltage alarm indication
Operation
Mode
Undervoltage occurs.
Undervoltage
alarm
*
Output voltage lower limit
*This indicator alternately
displays alarm (
) and
Output
current
the output voltage lower
limit.
Peak-hold
current
Maintenance
forecast
monitor
Note: 1. When the voltage is restored to the set value or higher and
the Key is pressed at the a01 display to return to the
output current display, the a01 alarm will be cleared and the
normal output display will return.
2. The above displays are for models with a maintenance
forecast monitor (S8VS-@@@24A@@).
27
S8VS
Self-Diagnostics Function
Numbers in the following table indicate the number used in Nomenclature on pages 15 and 17.
Setting after
restoration
(6) Main display
Description
Output status
Restoration method
Automatic reset.
Noise detected in voltage or
current
No change
No change
---
Maintenance
forecast output
terminal (Yrs) turns
OFF.
Overheated
Automatic reset.
No change
h\t
e01
Undervoltage
output terminal (DC
LOW) turns OFF.
Undervoltage alarm set value
memory error
Press and hold the Up Key U (9) or Down
Key D (10) for three seconds and check
the set value of the corresponding point.
Shipment setting or
value set in the
The set value must return to the shipment setting mode again
setting
Maintenance
forecast output
terminal (Yrs) turns
OFF or total run
time output terminal
(kh) turns OFF.
Memory error of alarm set value
of maintenance forecast monitor
or total run time monitor
e02
Undervoltage
output terminal (DC
LOW) turns OFF.
Maintenance
Turn the AC input OFF then ON again.
Other memory error
forecast output
terminal (Yrs) turns dealer.
OFF or total run
If the Product is not reset, contact the
No change
e03
time output terminal
(kh) turns OFF.
Undervoltage
output terminal (DC
LOW) turns OFF.
Maintenance
forecast output
terminal (Yrs) turns dealer.
OFF or total run
time output terminal
(kh) turns OFF.
Turns the AC input OFF then ON again.
If the Product is not reset, contact the
e04,
e05
Hardware error
(S8VS-48024A/B only)
No change
Note: 1. External noise is probable as a cause of “---”, “e01”, “e02”, “e03”, “e04”, and “e05” errors.
2. Operation out of the derating curve area, ventilation error, and incorrect mounting direction are probable as a cause of “h\t” error.
3. If the “h\t” error state continues for more than three hours, the maintenance forecast monitor function becomes invalid. The Yrs output
(Maintenance forecast output terminal (Yrs)) will remain OFF (no continuity).
Replace the power supply if this condition occurs even if the output is correct, as internal parts may be deteriorated.
4. The “h\t” error detection function is only for the S8VS-@@@24A@@.
28
S8VS
Indication and Output
Maintenance Forecast (S8VS-@@@24A@@)
When the Product is purchased, “ful” will be indicated. As
electrolytic capacitors deteriorate, indication changes to “hlf” (Refer
to page 30). “ful” will be indicated for the maintenance forecast
display for approximately one month after the Power Supply is first
turned ON. The accumulated value will then be displayed depending
on the ambient conditions thereafter. (However, the “hlf” indication
may not appear, depending on the usage environment and the set
value for maintenance forecast.)
Displays when the maintenance forecast has reached the set value.
Operation
Mode
The maintenance forecast
has reached the set value.
Maintenance
forecast
monitor
(See note.)
S8VS-06024A:
Remaining time
until replacement
After the remaining time to maintenance is reduced to less than two
years, indication automatically changes to a value, which decreases
from “1.5” to “1.0” to “0.5” to “0.0” (year) as the running hours
increase. If the remaining time becomes less than 0.5 year, an alarm
(a02) and “0.0” are indicated alternately.
Output
voltage
Note: This indicator alternately
displays alarm (
)
and the maintenance
time until replacement.
S8VS-09024A@@/S8VS-12024A@,
S8VS-18024A@/S8VS-24024A@/S8VS-48024A:
Output
current
If the maintenance forecast setting L (which can be set arbitrarily from
0.0 to 5.0 years in 0.5-year steps) is set to a value larger than two
years, the indication automatically changes to a value (L - 0.5) after
the remaining time to maintenance is reduced to the set years, and an
alarm (a02) and the remaining time are indicated alternately.
If the setting is less than 2.0 years, the indication changes to a value
(1.5) after the remaining time becomes less than two years, and after
the remaining time becomes less than the set time, an alarm (a02)
and the remaining time (L - 0.5) are indicated alternately.
Peak-hold
current
If the alarm (a02) and a numeric value are indicated alternately, a
transistor (maintenance forecast output terminal (Yrs)) will turn OFF
to indicate the need for maintenance. (The transistor turns OFF when
the maintenance forecast time is reached, i.e., there will be no
continuity at the maintenance forecast output terminal.)
In the case that the
remaining time is
reduced to smaller
than 0.5 year and an
alarm is issued.
Note: 1. The remaining time to maintenance is based on continuous
operation, not including the time when the power supply is
turned OFF.
2. “ful” will be indicated until approximately one month of
time is accumulated to estimate the speed of deterioration
and the output will remain ON (continuity at the
maintenance forecast output terminal (Yrs)).
3. For details on the display, refer to Relationship between
Indicated Values and Output of Set Values under
Maintenance Forecast Monitor Function on page 30.
29
S8VS
Maintenance Forecast Monitor Function
The Power Supply is equipped with electrolytic capacitors.
The electrolyte inside the electrolytic capacitor penetrates the sealing
rubber and evaporates as time passes since it is manufactured, which
causes deterioration of characteristics such as decreasing the
capacitance, etc.
The maintenance forecast monitor function shows an approximate
period left for maintenance of the Power Supply due to deterioration
of electrolytic capacitors. When the period left for maintenance that
the power supply forecasts reaches the set value, an alarm is
indicated and an output signal is triggered.
Due to this deterioration of the characteristics of the electrolytic
capacitor, the Power Supply decreases its performance as time
passes.
Use this function to know the approximate replacement timing of the
Power Supply.
Note: The maintenance forecast monitor function indicates an
approximate period left for maintenance, based on
deterioration of the electrolytic capacitor. It does not predict
failures caused by other reasons.
Relationship between Indicated Values and Output of Set Values
L: Maintenance forecast set value (See note.) In case of setting L between 2.5 and 5.
0.0 to 5.0, 0.5 steps
Initial capacity
(L−0.5)
"1.0" is displayed on the main display for the
duration that the maintenance forecast up to
replacement satisfies the condition 1.0 ≤ T < 1.5.
Capacity level
at replacement
5.0
2.5
2.0
1.5
1.0
0.5
0
Capacity of Capacitor
Main display
T: Maintenance time
until replacement
L=2.5
L=0.5
Maintenance forecast monitor output
The numerical value
decreases with time.
Note: This function can be set only on the S8VS-09024A@@, S8VS-12024A@, S8VS-18024A@, S8VS-24024A@, and S8VS-48024A.
Principle of Operation
Reference Values (15-W to 480-W Models)
The deterioration speed of the electrolytic capacitor varies
considerably according to the ambient temperature. (Generally the
speed follows “Rule of Two for every 10°C”; for every 10°C increase
in temperature the rate of degradation doubles according to
Arrhenius’s equation.) The S8VS-@@@24A@@ monitors the
temperature inside the power supply, and calculates the amount of
deterioration according to the running hours and inside temperature.
Judging by this amount of deterioration, the power supply will give the
alarm indication and output when the period left for maintenance
reaches the set value.
Item
Value
Definition
MTBF stands for Mean Time
Between Failures, which is
15 W to 240 W: calculated according to the
135,000 hr min. probability of accidental device
480 W:
Reliability
(MTBF)
failures, and indicates reliability of
devices.
Therefore, it does not necessarily
represent the life of the Product.
60,000 hr min.
The life expectancy indicates
average operating hours under the
ambient temperature of 40°C and a
load rate of 50%. Normally this is
determined by the life expectancy of
the built-in aluminum electrolytic
capacitor.
Note: 1. Due to degradation of internal electronic parts, replace the
power supply approximately 15 years after purchase even if
indication and output of maintenance forecast monitor are
not issued.
Life
expectancy
10 yr min.
2. The maintenance forecast is accelerated or decelerated
according to operating conditions. Periodically check
indication.
3. Acceleration or deceleration of the maintenance forecast
may cause the output to repeatedly go ON/OFF.
Only the S8VS-09024A@@, S8VS-12024A@, S8VS-
18024A@, S8VS-24024A@, and S8VS-48024A are
equipped with output.
Note: The maintenance forecast is the service life (the power
supply’s internal temperature is monitored at all times) of the
internal electrolytic capacitor in actual operating conditions,
and varies according to the customer’s operating conditions.
15 years is taken as the maximum period of the maintenance
forecast.
4. The accuracy of the maintenance forecast function may be
adversely affected by applications in which the AC input is
frequently turned ON/OFF.
30
S8VS
Time Chart
Models with Total Run Time Monitor
(S8VS-@@@24B@@/S8VS-@@@24BE@)
Total run time
S8VS-06024B
50 kh
The accumulated value of the operating time of the Power Supply is
displayed as the total run time. 0 (kh) will be displayed initially after
purchase and then the display will advance in 1-kh steps as the
operating time accumulates. The S8VS-06024B, however, does not
have an alarm function (setting, display, or output).
S8VS-09024B@@/S8VS-09024BE@/
S8VS-12024B@/S8VS-12024BE/
S8VS-18024B@/S8VS-18024BE/
0 kh
S8VS-24024B@/S8VS-24024BE/S8VS-48024B
The display will appear when the set value for the total run time has
been reached.
AC input
Alarm output
Set value = 50 kh
(See note.)
Operation mode
* Setting is possible for the following models only:
S8VS-09024B@@, S8VS-09024BE@, S8VS-12024B@,
S8VS-12024BE, S8VS-18024B@, S8VS-18024BE,
S8VS-24024B@, S8VS-24024BE, S8VS-48024B
Note: 1. The total run time does not include the time that the Power
Supply is OFF.
Total run time set value reached.
Total run time
2. The total run time measures the total time that power is
being supplied and is not related in any way to deterioration
in the electrolytic capacitor built into the Power Supply or to
the effects of the ambient temperature.
(See note.)
Total run time
Note: The alarm (a02)
and the total run
time will be
displayed
Output
voltage
alternately.
Output
current
Peak hold
current
The accumulated value of the operating time of the Power Supply is
displayed as the total run time. 0 (kh) will be displayed initially after
purchase and then the display will advance in 1-kh steps as the
operating time accumulates. When the total run time reaches the
alarm set value, the alarm (a02) and the total run time will be
displayed alternately and a transistor (total run time output terminal
(kh)) will output the status externally.
(Alarm set value reached = OFF, i.e., no continuity at the total run time
output terminal (kh))
The alarm set value can be changed in the setting mode.
The S8VS-09024BE@, S8VS-12024BE, S8VS-18024BE, and S8VS-
24024BE do not have an alarm output.
Example: Alarm Displays When a Total Run Time Set Value of
88 kh Is Reached
Note: The total run time cannot be reset. To clear the alarm, change
the alarm set value to a value higher than the value displayed
for the total run time.
31
S8VS
Safety Precautions
!CAUTION
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or
repair the Product or touch the interior of the
Product.
Wiring
• Connect the ground completely. A protective earthing terminal
stipulated in safety standards is used. Electric shock or malfunction
may occur if the ground is not connected completely.
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
Minor burns may occasionally occur. Do not touch
the Product while power is being supplied or
immediately after power is turned OFF.
• Do not apply more than 100-N force to the terminal block when
tightening it.
• Be sure to remove the sheet covering the Product for machining
before power-ON so that it does not interfere with heat dissipation.
• When wiring a screwless terminal block, do not insert more than
one wire into a single terminal.
• When using a screwless terminal block, connect or disconnect the
I/O wire to each terminal while inserting an appropriate tool, such
as a flat-blade screwdriver, into the tool insertion hole. Make sure
that the wire is securely connected to the terminal after wiring. Do
not insert wires into the tool insertion holes.
If a wire is not inserted far enough or if it is loose, electric shock,
fire, or equipment failure may occur. Strip the wires according to
specifications. Insert an appropriate tool, such as a flat-blade
screwdriver, into the tool insertion hole, insert the wire until the
stripped portion is no longer visible, and then remove the tool.
Make sure that the wires are securely connected to the terminal
block after wiring. Never insert wires into the tool insertion holes.
Fire may occasionally occur. Tighten terminal screws
to the specified torque (15- and 30-W models: 0.8 to
1.0 N·m/60-, 90-,120-, 180-, 240-, and 480-W models:
1.08 N·m).
Minor injury due to electric shock may occasionally
occur. Do not touch the terminals while power is
being supplied. Always close the terminal cover after
wiring.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal
or conductors or any clippings or cuttings resulting
from installation work to enter the Product.
Wire hole
Precautions for Safe Use
Mounting
• Take adequate measures to ensure proper heat dissipation to
increase the long-term reliability of the Product. Be sure to allow
convection in the atmosphere around devices when mounting. Do
not use in locations where the ambient temperature exceeds the
range of the derating curve.
3.7 mm
• When cutting out holes for mounting, make sure that cuttings do
not enter the interior of the Products.
Tool insertion hole
• Use the following material for the wires to be connected to the
S8VS to prevent smoking or ignition caused by abnormal loads.
*1
Recommended Wire Type
15-W and 30-W Models
Model
Stranded wire
Solid wire
AWG18 to 14
AWG18 to 16
*1. Convection of air
*2. 20 mm min.
S8VS-03005
(0.9 to 2.0 mm2)
(0.9 to 1.1 mm2)
*2
*1
AWG20 to 14
AWG20 to 16
Other models
(0.5 to 2.0 mm2)
(0.5 to 1.1 mm2)
15-W and 30-W Models
• Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts. Use
the Product within the derating curve for the mounting direction that
is used.
• Use a mounting bracket when the Product is mounted facing
horizontally.
• Heat dissipation will be adversely affected. When the Product is
mounted facing horizontally, always place the side with the label
facing upward.
60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models
Recommended wire size
Model
Input
terminals
Output
terminals
Alarmoutput
terminals
S8VS-06024@
AWG14 to 20 ---
(Crosssection:
0.517 to
S8VS-
09024@@@@
2.081 mm2)
• Operate the Power Supply within a range that is 5°C less than the
values in the derating curve in Engineering Data on page 18 if the
Power Supply is used with an installation spacing of 10 mm min.
(20 mm max.) on the left and right.
AWG14 to 18
(Crosssection:
0.823 to
S8VS-
12024@@@
AWG14 to 20
(Crosssection:
0.517 to
AWG18 to 28
(Cross
section:0.081
to 0.823 mm2)
(Wires to be
stripped:
2.081 mm2)
2.081 mm2)
AWG14 to 16
(Crosssection:
1.309 to
60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models
• Improper mounting will interfere with heat dissipation and may
occasionally result in deterioration or damage of internal parts. Use
the standard mounting method only.
• The internal parts may occasionally deteriorate and be broken due
to adverse heat radiation. Do not loosen the screw on the side face
of the main body.
S8VS-
18024@@@
2.081 mm2)
9 to 10 mm)
S8VS-
24024@@@
AWG14
AWG 14 to 16
(Crosssection:
1,309 to
(Crosssection:
2.081 mm2)
S8VS-48024@
2,081 mm2)
32
S8VS
• Strip I/O wires for 11 mm when using a screwless terminal block.
* The rated current for output terminals is 10 A per terminal. Be sure
to use multiple terminals simultaneously for current that exceeds
the terminal rating. When applying a current of 10 A or more, use at
least two terminals each for the positive and negative wires.
1
2
60-, 90-, 120-,
180-, 240-W
Models
Installation Environment
6
7
• Do not use the Power Supply in locations subject to shocks or
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration
source.
8
9
10
• Install the Power Supply well away from any sources of strong,
high-frequency noise and surge.
4
5
12
(Yrs/kh)
Operating Life
• The life of a Power Supply is determined by the life of the
electrolytic capacitors used inside. Here, Arrhenius Law applies,
i.e., the life will be cut in half for each rise of 10°C or the life will be
doubled for each drop of 10°C. The life of the Power Supply can
thus be increased by reducing its internal temperature.
3
11
13
(DC LOW) (COMMON)
480-W Models
Ambient Operating and Storage Environments
1
2
• Store the Power Supply at a temperature of −25 to 65°C and a
humidity of 25% to 90%.
• Do not use the Power Supply in areas outside the derating curve
otherwise, internal parts may occasionally deteriorate or be
damaged.
• Use the Power Supply at a humidity of 25% to 85%.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive
gases may enter the interior of Products.
6
7
9
10
8
4
5
16
15
3
12 11
14 13
S8VS-@@@24A@@ Models only
(DC LOW)
(Yrs/kh)
Satisfy the following conditions when storing the Power Supply for
long periods of time to maintain its remaining service life function.
When storing for more than three months, store within an ambient
temperature range of −25 to +30°C and the humidity range of 25% to
70%.
Overcurrent Protection
• Internal parts may possibly deteriorate or be damaged if a
short-circuited or overcurrent state continues during operation.
• Internal parts may possibly deteriorate or be damaged if the Power
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
Periodic Check for Models with Indication
Monitor Except 60-W Models
It may take from several years to more than 10 years under general
operating conditions for the power supply to output the maintenance
forecast monitor alarm (S8VS-@@@24A@@). The total run time
monitor (S8VS-@@@24B@@/S8VS-@@@24BE@) may be a similar
number of years as the maintenance forecast monitor according to
some settings. During operation over an extended period of time,
periodically check if the maintenance forecast monitor output (Yrs) or
total run time monitor output (kh) is correctly functioning by the
following procedure.
• The DC ON indicator (green) flashes if the overload protection
function operates.
Alarm Output for Models with Indication Monitor
Except 60-W and BE Models
When using the alarm output, sufficiently consider the maximum
ratings, residual voltage, and leakage current.
Transistor output:
Sinking for S8VS-24A@/@@@24B@ models
Sourcing for S8VS-@@@24AP@/@@@24BP@
models
1. Select the operation mode.
2. Check that the output (Yrs/kh) is turned ON (with continuity).
3. In the operation mode, press and hold the Down Key D (10) and
the Mode Key M (8) simultaneously for at least three seconds.
The main display (6) changes to “a02.”
An inactive output (Yrs/kh) (no continuity) in the “a02” indication
indicates the correct function.
4. Release keys to return to the regular state.
Sinking/Sourcing for S8VS-48024A/B models
30 VDC max., 50 mA max.
ON residually voltage:2 V max.
OFF leakage current: 0.1 mA max.
Charging a Battery
If you connect a battery as the load, install overcurrent control and
Note: DC output stays ON during the periodical check.
overvoltage protection circuits.
33
S8VS
However, use the lower of the two maximum rated output currents
as the current to the loads.)
Output Voltage Adjuster (V.ADJ)
• The output voltage adjuster (V.ADJ) may possibly be damaged if it
is turned with unnecessary force. Do not turn the adjuster with
excessive force.
+V
+V
INPUT
−V
• After completing output voltage adjustment, be sure that the output
capacity or output current does not exceed the rated output
capacity or rated output current.
0 V
+V
INPUT
15-W, 30-W Models
−V
−V
• If the output voltage is set to a value less than −10%, the
undervoltage alarm function may operate.
• Depending on the model, internal circuits may be damaged due to
startup failure when the power is turned ON if loads such as a
servomotor or operational amplifier may operate in series.
Therefore, connect bypass diodes (D1, D2) as shown in the
following figure.
If the list of models that support series connection of outputs says
that an external diode is not required, an external diode is also not
required for positive/negative outputs.
60-W, 90-W, 120-W, 180-W, 240-W, and 480-W Models
• If the detection voltage of the undervoltage alarm function is at the
factory setting and the output voltage is set to a value of 20 V or
less, the undervoltage alarm function may operate.
DIN Rail Mounting
To mount the Block on a DIN Rail, hook portion (A) of the Block onto
the rail and press the Block in direction (B).
+V
INPUT
D1
−V
(A)
+V
INPUT
D2
−V
(B)
To dismount the Block, pull down portion (C) with a flat-blade
screwdriver and pull out the Block.
• Use the following information as a guide to the diode type, dialectic
strength, and current.
• Type: Schottky barrier diode
• Dielectric strength (VRRM): Twice the rated Power Supply output
voltage or higher
• Forward current (IF): Twice the rated Power Supply output
current or higher
30 mm min.
Parallel Operation
The Product is not designed for parallel operation.
(C)
Track stopper
Series Operation
(24-V Model)
Incorrect
AC (L)
+V
Two power supplies can be connected in series.
AC (N)
−V
Correct
AC (L)
AC (N)
+V
AC (L)
+V
−V
AC (N)
−V
AC (L)
AC (N)
+V
Backup Operation
−V
•
Backup operation can be performed. Backup operation provides
protection by using an extra Power Supply even if the output
current is sufficient with one Power Supply. If one of the Power
Supplies fails, the second Power Supply still provides sufficient
power.
Note: 1. The diode is connected as shown in the figure. If the load is
short-circuited, a reverse voltage will be generated inside
the Power Supply. If this occurs the Power Supply may
possibly deteriorate or be damaged. Always connect a
diode as shown in the figure.
A
D1
Select a diode having the following ratings.
+V
Type
Dielectric strength (VRRM) Twice the rated output voltage or above
Forward current (IF) Twice the rated output current or above
Schottky Barrier diode
−V
B
D2
+V
2. Although Products having different specifications can be
connected in series, the current flowing through the load
must not exceed the smaller rated output current.
−V
Use the same model for Power Supplies A and B.
• Use a load capacity that can be supplied by either Power Supply A
or Power Supply B alone.
3. Serial operation is not possible with 5-V and 12-V models.
Making Positive/Negative Outputs
• If backup operation is used, be sure to connect a diode to both
Power Supply A and Power Supply B as shown in the above figure
so that the backup Power Supply is not affected by a failed Power
Supply.
Use the following information as a guide to the diode type, dialectic
strength, and current.
• The outputs are floating outputs (i.e., the primary circuits and
secondary circuits are separated). You can therefore make
positive and negative outputs by using two Power Supplies.
You can make positive and negative outputs with any of the
models.
If positive and negative outputs are used, connect Power Supplies
of the same model as in the following figure. (Combinations with
different output capacities or output voltages can be made.
34
S8VS
• Type: Schottky barrier diode
• Dielectric strength (VRRM): Rated Power Supply output voltage or
higher
• Forward current (IF): Twice the rated Power Supply output
current or higher
• Increase the output voltage setting of Power Supply A and Power
Supply B by the drop in the forward voltage (VF) of diodes D1 and
D2.
Also, the diodes will cause a power loss equivalent to the Power
Supply output current (IOUT) times the diode forward voltage (VF).
Therefore, cooling measures must be implemented so that the
temperature of the diodes decreases to the catalog value or lower.
• Because of the load power and power loss due to the diodes, do
not exceed the rated power of one Power Supply (rated output
voltage x rated output current).
In Case There Is No Output Voltage
The possible cause for no output voltage may be that the overcurrent
or overvoltage protection has operated. The internal protection may
operate if a large amount of surge voltage such as a lightening surge
occurs while turning ON the power supply.
In case there is no output voltage, please check the following points
before contacting us:
• Checking overload protected status:
Check whether the load is in overload status or is short-circuited.
Remove wires to load when checking.
• Checking overvoltage or internal protection:
Turn the power supply OFF once, and leave it OFF for at least
3 minutes. Then turn it ON again to see if this clears the condition.
Audible Noise at Power ON
(120-W, 180-W, 240-W, and 480-W Models)
A harmonic current suppression circuit is built into the Power Supply.
This circuit can create noise when the input is turned ON, but it will
last only until the internal circuits stabilize and does not indicate any
problem in the Product.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
35
MEMO
36
Read and Understand this Catalog
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have
any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year
(or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with
your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
OMRON Corporation
Tokyo, JAPAN
Industrial Automation Company
Authorized Distributor:
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
© OMRON Corporation 2002 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Printed in Japan
0312
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
CSM_5_2_0312
Cat. No. T026-E1-08
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明