V600-D23P66N [OMRON]

Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems;
V600-D23P66N
型号: V600-D23P66N
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems

文件: 总34页 (文件大小:3229K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Electromagnetic Coupling RFID System  
V600  
Non-contact Data Communications System  
• New compact, slim Controller with two input channels added to  
the lineup.  
• Superior environmental resistance.  
• Heat-resistant Data Carrier available (150°C max.).  
• Large memory capacity of 8 kbytes for Built-in-battery Data Car-  
riers and 254 bytes for Battery-less Data Carriers.  
• Built-in-battery Data Carriers have a battery life detecting func-  
tion.  
• Data of Battery-less Data Carriers with small memory capacity  
can be overwritten 300,000 times at normal temperatures.  
• Thin, compact, and low-cost Data Carriers are available.  
Transmission distance of 100 mm max.  
• CE marking/FCC approvals.  
Ordering Information  
Data Carriers  
Item  
Model  
Specifications/Design/Memory capacity  
Large Memory  
Capacity  
Built-in-battery Data Car- V600-D8KR12  
riers  
Rectangular compact  
65 × 40 × 15 mm  
8 Kbytes  
V600-D8KR13  
Thin rectangular  
86 × 54 × 10.3 mm  
V600-D8KR04  
Intermediate-range rectangular  
86 × 54 × 20 mm  
Battery-less Data Carri-  
ers  
Intermediate-range rectangular  
86 × 54 × 20 mm  
V600-D8KF04  
Replaceable-batteryData V600-D2KR16  
Carriers  
Compact  
65 × 40 × 5 mm  
2 Kbytes  
Small Memory  
Capacity  
Battery-less Data Carri- V600-D23P71  
ers  
Ultrathin card-type  
86 × 54 × 1.5 mm  
254 bytes  
V600-D23P72  
Thin half-size card-type  
50 × 34 × 1.5 mm  
V600-D23P66N  
V600-D23P66SP  
Rectangular  
34 × 34 × 3.5 mm  
Rectangular package with PFA  
95 × 36.5 × 6.5 mm  
V600-D23P61  
V600-D23P53  
V600-D23P54  
V600-D23P55  
Rectangular compact  
32 × 24 × 6 mm  
Round super-compact  
8 dia. × 5 mm  
Round compact  
12 dia. × 6 mm  
Round super-compact  
8 dia. × 5 mm  
Electromagnetic Coupling RFID System V600  
1
R/W Heads  
Item  
Model  
Specifications/Design  
Rectangular type  
V600-H07 (0.5 m)  
V600-H07 (2 m)  
V600-H07 (5 m)  
V600-H07 (10 m)  
Dimensions: 100 × 100 × 30 mm  
0.5-m cable  
2-m cable  
5-m cable  
10-m cable  
V600-H11 (0.5 m)  
V600-H11-R (0.5 m)  
V600-H11 (2 m)  
V600-H11 (5 m)  
V600-H11 (10 m)  
V600-H51 (0.5 m)  
V600-H51 (2 m)  
V600-H51 (5 m)  
V600-H51 (10 m)  
V600-H52 (0.5 m)  
V600-H52 (2 m)  
V600-H52 (5 m)  
V600-H52 (10 m)  
Dimensions: 53 × 40 × 23 mm  
0.5-m cable  
0.5-m cable  
2-m cable  
5-m cable  
10-m cable  
0.5-m cable  
2-m cable  
5-m cable  
10-m cable  
0.5-m cable  
2-m cable  
5-m cable  
10-m cable  
Cylinder type  
Dimensions: 22 dia. × 80 mm  
Dimensions: 22 dia. × 85 mm  
Separate-amplifier Amplifier V600-HA51 (2 m)  
73.8 × 22.6 × 36.5 mm, with 2-m cable  
73.8 × 22.6 × 36.5 mm, with 5-m cable  
73.8 × 22.6 × 36.5 mm, with 10-m cable  
12 dia. × 35 mm deep, with 2-m cable  
type  
section  
V600-HA51 (5 m)  
V600-HA51 (10 m)  
V600-HS51  
Sensor  
section  
V600-HS61  
30.5 × 18 × 10 mm, with a 2-m cable  
ID Controllers  
Item  
Model  
Specifications/Design  
DC Power Supply  
24 VDC  
Two R/W Head channels  
105 × 90 × 65 mm  
Host RS-232C, RS-422,  
and RS-485 interfaces  
V600-CA5D02  
V600-CD1D-V3  
V600-CM1D  
24 VDC  
Single R/W Head connect-  
able  
115 × 68 × 80 mm  
24-VDC, 5-VDC 2-system  
RS-232C host interface  
input  
Single R/W Head connect-  
able  
Board type  
POWER  
1
2
3
4
IN  
1
OUUT  
5
DC Power Supply  
V600-IDSC02  
V600-IDSC04  
2
3
24 VDC  
RS-232C interface  
Two R/W Heads connect-  
able  
MAOON  
No.  
X10  
DC24VV  
IINNPUT  
TEST  
ON  
HEAD1  
HEAD22  
POWWER  
1
2
3
4
INN  
1
OUT  
5
2
3
Four R/W Heads connect-  
able  
MAON  
No..  
MAON  
No.  
X10  
X10  
DC24V  
INPUT  
TEST  
ON  
TESTT  
ON  
HEAADD1  
HEAADD1  
HEAD2  
HEAD2  
2
Electromagnetic Coupling RFID System V600  
Accessories (Order Separately)  
Item  
Model  
Specifications/Design  
Extension cable for  
R/W Heads  
V600-A45  
V600-A44  
V600-A40  
V600-A41  
V600-A42  
V600-A56  
V600-A55  
V600-A50  
V600-A51  
V600-A52  
V600-A81  
Standard cable  
3-m cable  
5-m cable  
10-m cable  
20-m cable  
30-m cable  
3-m cable  
5-m cable  
10-m cable  
20-m cable  
30-m cable  
Non-water-resistant connectors  
Robotic cable  
Non-water-resistant connectors  
Holder  
For the V600-D2KR16  
*Mount with M3 flat countersunk head screws (at least two).  
V600-A84  
V600-A86  
For the V600-D23P71/D23P72  
Ultrasonic deposition can be used on the plastic container.  
Attachment  
For the V600-D23P66N  
RS-232C Cables (Order  
Connectors for ID Controllers  
Separately)  
(One Set per Unit)  
Model  
XW2Z-200S  
XW2Z-500S  
Cable length  
Compatible ID Controllers  
Model  
Name  
Compatible ID Controllers  
2 m  
5 m  
XM2A-0901  
Connector  
Plug  
V600-CD1D-V3  
V600-CM1D  
V600-CD1D-V3  
V600-CM1D  
XM2S-0911  
Connector  
Hood  
MC1.5/5-STF-3.5 RS-422/  
(made by Phoenix RS-485  
V600-CA5D02  
Contact)  
communica-  
tions  
connector  
Electromagnetic Coupling RFID System V600  
3
Specifications  
Battery-less Data Carriers with Small Memory Capacity  
Shape Ultrathin  
Card-type  
Ultrathin Rectangular Chemical- Rectangular  
Round  
Super-  
compact  
Round  
Compact  
Round  
Super-  
compact  
Half-size  
Compact  
resistant  
Compact  
Card-type  
Model  
V600-  
D23P71  
V600-  
D23P72  
V600-  
D23P66N  
V600-  
D23P66SP  
V600-  
D23P61  
V600-  
D23P53  
V600-  
D23P54  
V600-  
D23P55  
Item  
Memory capacity  
Memory type  
254 bytes  
EEPROM (non-volatile memory)  
Transmission distance Refer to “Transmission Distance Specifications for Battery-less Data Carriers with Small Memory Capacity” on  
page 10.  
Data retention time  
(after writing data)  
10 years  
10 years (40 10 years  
to 110°C)  
1 year (40 to  
150°C)  
10 years (40  
to 110°C)  
1 year (40 to  
150°C)  
Number of  
overwrites  
(per address)  
(Refer to  
separate  
item for  
Up to 0°C 800,000 times  
Up to  
400,000 times  
300,000 times  
100,000 times  
25°C  
Up to  
60°C  
ambient  
Up to  
temperature) 85°C  
Transmission error  
detection  
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)  
Ambient  
temperature storage  
For data 20 to 110°C  
−40 to 150°C 40 to 110°C 40 to 85°C  
(See note.)  
−40 to 150°C  
(See note.)  
For  
reading/  
writing  
10 to 70°C  
20 to 85°C 20 to 70°C 25 to 70°C  
25 to 85°C  
Storage temperature  
20 to 110°C  
−40 to 150°C 40 to 110°C 40 to 85°C  
(See note.)  
−40 to 150°C  
(See note.)  
Ambient humidity  
Operating: 35% to 95%  
IEC 60529: IP67  
Degree of protection  
IEC 60529:  
IP68  
IEC 60529:  
IP67  
IEC 60529: IP67  
IEC 60529:  
IP67  
10 to 2,000 Hz, 3.0-mm double amplitude, 300 m/s2 accel-  
eration for 30 min each in 3 directions (90 min total)  
10 to 2,000 Hz,  
1.5-mm double  
amplitude,  
10 to 2,000 Hz,  
1.5-mm double  
amplitude,  
Vibration resistance  
(destruction)  
10 to 2,000 Hz, 3.0-mm  
double amplitude, 300 m/s2  
acceleration for 30 min  
each in 3 directions (90 min  
total)  
150 m/s2 accel-  
eration 10  
150 m/s2 accel-  
eration 10  
times each in 3  
directions (15  
min)  
times each in 3  
directions (15  
min)  
1,000 m/s2 3 times each in 3  
directions (18 times total)  
1,000 m/s2 3 times each in 3 directions (18 times total)  
Shock resistance  
(destruction)  
500 m/s2 3  
times each in 3  
directions (18  
times total)  
500 m/s2  
3
times each in 3  
directions (18  
times total)  
Weight  
Approx. 15 g Approx. 5 g Approx 6.5 g Approx. 19 g Approx. 5.8 g Approx. 0.4 g Approx. 1.0 g Approx. 0.6 g  
Note: The 150°C heat resistance was confirmed by leaving the Unit at 150°C for 1,000 continuous hours, and by a thermal shock test consisting  
of 1,000 10°C/150°C cycles of 30 min each. No defect was found among the 22 test samples.  
4
Electromagnetic Coupling RFID System V600  
Data Carriers with Large Memory Capacity  
Shape  
Built-in-battery  
Battery-less  
Rectangular  
Replaceable-battery  
Rectangular  
Compact  
Rectangular Thin  
Rectangular  
Rectangular  
Compact with  
Replaceable Battery  
Intermediate Range Intermediate Range  
Model  
V600-D8KR12  
V600-D8KR13  
V600-D8KR04 V600-D8KF04  
V600-D2KR16  
Item  
Memory capacity  
Memory type  
8 KB  
SRAM (volatile memory)  
2 KB  
FeRAM  
SRAM  
(nonvolatile memory) (volatile memory)  
Transmission distance Refer to “Transmission Distance Specifications for Data Carriers with Large Memory Capacity (Built-in-battery/Battery-  
less/Replaceable-battery)” on page 15  
Battery life (See note  
1.)  
Refer to “Battery Life” on page 22  
--- (See note 4.)  
1,000 million  
2 years (at 25°C)  
(See note 2.)  
Number of reads/writes Unlimited  
Unlimited (Does not  
affect battery life)  
Transmission error  
detection  
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)  
Ambient  
temperature storage  
For data 40 to 70°C  
15 to 70°C  
0 to 50°C  
For  
25 to 70°C  
reading/  
writing  
Storage temperature  
Ambient humidity  
Storage humidity  
40 to 70°C  
15 to 70°C  
35% to 85%  
35% to 95%  
35% to 95%  
IEC 60529: IP67  
Degree of protection  
IEC 60529: IP50 (dust-  
proof) (See note 3.)  
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in  
X, Y, and Z directions  
Vibration resistance  
(destruction)  
10 to 150 Hz, 0.75-mm  
single amplitude, 100-  
m/s2 acceleration for  
30 min each in X, Y,  
and Z directions  
1,000 m/s2 3 times each in X, Y, and Z directions (18 times total)  
500 m/s2 3 times each 300 m/s2 3 times each  
Shock resistance  
(destruction)  
in X, Y, and Z direc-  
tions (18 times total)  
in X, Y, and Z direc-  
tions (18 times total)  
Weight  
Approx. 70 g  
Approx. 160 g  
Approx. 150 g  
Approx. 15 g  
Note: 1. A low battery detection function is built-in.  
2. The battery life is applicable for batteries used at a temperature of 25°C. Refer to “Temperature and Battery Life” on page 22 for details  
on the relationship between temperature and battery life. The lithium battery is commercially available (CR2016).  
3. The Data Carrier is dustproof when the provided battery replacement cover seal is used.  
4. Data holding time: 10 years  
Electromagnetic Coupling RFID System V600  
5
Read/Write (R/W) Heads with Built-in Amplifier  
Model  
V600-H07  
V600-H11/H11-R  
V600-H51  
V600-H52  
Item  
Oscillation frequency  
Ambient temperature  
Storage temperature  
Ambient humidity  
530 kHz  
25 to 70°C  
40 to 85°C  
35% to 95%  
35% to 95%  
10 to 60°C  
25 to 75°C  
Storage humidity  
Insulation resistance  
Dielectric strength  
Degree of protection  
50 Mmin. (at 500 VDC) between cable terminals and case  
1,000 VAC, 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)  
IEC 60529: IP67  
10 to 500 Hz, 1.0-mm single amplitude, 150 m/s2 acceleration with 3 sweeps of 11 min each in X, Y, and Z directions  
Vibration resistance  
(destruction)  
Destruction: 500 m/s2 3 times each in X, Y, and Z directions (18 times total)  
Shock resistance  
Cable length (See note 1.) Standard lengths of 0.5 m, 2 m, 5 m, and 10 m.  
Wireless transmission  
error detection  
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)  
Indicators  
Weight  
Power: green; transmission: orange  
Approx. 1 kg  
Approx. 650 g (with 10-m cable)  
(with 10-m cable)  
Note: 1. Extension cables are also available. The maximum cable length is 30.5 m for the V600-H07 and 50.5 m for the V600-H11/H51/H52.  
2. The connectors are not water-resistant.  
6
Electromagnetic Coupling RFID System V600  
Read/Write (R/W) Heads with Separate Amplifier  
Model  
Sensor section  
Amplifier section  
V600-HA51  
V600-HS51  
V600-HS61  
Item  
Oscillation frequency  
Ambient temperature  
Storage temperature  
Ambient humidity  
530 kHz  
---  
10 to 60°C  
25 to 75°C  
35% to 95%  
Insulation resistance  
Dielectric strength  
Degree of protection  
50 Mmin. (at 500 VDC) between cable terminals and case  
1,000 VAC 50/60 Hz for 1 min between cable terminals and case (Leakage current: 1 mA max.)  
IEC 60529: IP67  
10 to 2,000 Hz, 1.5-mm single amplitude, 300 m/s2 accel-  
eration with 2 sweeps of 15 min each in 3 directions  
IEC 60529: IP66  
Installed in panel  
Vibration resistance  
(destruction)  
10 to 2,000 Hz, 1.5-mm single am-  
plitude, 300-m/s2 acceleration with 2  
sweeps of 11 min each in 3 direc-  
tions  
DIN Track installa- 10 to 500 Hz, 1.0-mm single ampli-  
tude, 150-m/s2 acceleration with 3  
sweeps of 11 min each in 3 direc-  
tions  
tion  
1,000 m/s2 3 times each in 3 directions (18 times total) 500 m/s2 3 times each in 3 directions (18 times total)  
Shock resistance  
(destruction)  
Cable length Sensor to  
amplifier  
2 m (fixed)  
---  
Amplifier to ---  
Standard lengths of 2 m, 5 m, and 10 m (See note 1.)  
controller  
Wireless transmission  
error detection  
16-bit CRC in both directions (CRC: Cyclic Redundancy Check)  
Indicators  
Weight  
---  
Power: green; transmission: orange  
Approx. 650 g (with 10-m cable)  
Approx. 70 g (with 2-m cable)  
Note: 1. Extension cables are also available. The maximum cable length is 50 m for the V600-HA51. Extension cables are not available for the  
V600-HS51/HS61.  
2. The connectors are not water-resistant.  
Electromagnetic Coupling RFID System V600  
7
ID Controllers  
Series  
V600 Series  
Model  
V600-CA5D02  
V600-CD1D-V3  
V600-CM1D  
Item  
Host interface  
RS-232C, RS-422, RS-485  
2
RS-232C  
1
Possible number of R/W  
Heads  
Power supply voltage  
24 VDC  
24 VDC  
24 VDC, 5 VDC  
Acceptablepowersupply 20.4 to 26.4 VDC  
voltage  
20.4 to 26.4 VDC  
20.4 to 26.4 VDC  
4.5 to 5.5 VDC  
Power consumption  
Insulation resistance  
Dielectric strength  
15 W max.  
7.2 W max.  
24 VDC: 7.2 W max.  
5 VDC: 1.5 W max.  
50 Mmin. (at 500 VDC) between power terminals and case, between I/O terminals and case, or between the power  
supply terminals and I/O terminals  
1,000 VAC, 50/60 Hz for 1 min be-  
tween the points listed above;  
Leakage current: 10 mA max.  
1,000 VAC, 50/60 Hz for 1 min between the points listed above;  
Leakage current: 10 mA max.  
Noise immunity  
1,500-V (p-p) pulses of 100-ns to 1-µs pulse width with a 1-ns rise time  
Vibration  
Destruction --- 10 to 150 Hz, 0.3-mm double amplitude for 32 min each in X, Y, and Z direc-  
resistance  
tions  
Malfunction 10 to 150 Hz, 0.2-mm double ampli- 10 to 150 Hz, 0.2-mm double amplitude for 32 min each in X, Y, and Z direc-  
tude, 15 m/s2 acceleration 10 times for  
8 min each in 3 directions  
tions  
Destruction: 200 m/s2 3 times each in X, Y, and Z directions (18 times total)  
---  
Shock  
resistance  
Destruction ---  
150 m/s2 3 times each in X, Y, and Z  
directions (18 times total)  
Malfunction  
Ambient temperature  
Ambient humidity  
Operating conditions  
Storage temperature  
Memory back-up  
10 to 55°C  
0 to 50°C  
35% to 85% (with no condensation)  
No corrosive gases  
25 to 65°C  
15 to 70°C  
A capacitor backs up the most recent Memory backup is not available. Error details, however, can be read from the  
error data and statistical error data for personal computer when the power is turned ON.  
up to 20 days (at 25°C) after a power  
interruption.  
Diagnostic functions  
Ground  
Checks for CPU errors, memory errors, power interruptions, and transmission errors  
Ground to 100 or less.  
Degree of protection  
Weight  
IEC 60529: IP30 (panel mounted)  
Approx. 300 g  
Approx 360 g  
Approx. 180 g  
8
Electromagnetic Coupling RFID System V600  
V600-IDSC  
Series  
Model  
V600-IDSC Series  
V600-IDSC02  
V600-IDSC04  
POWER  
POWER  
1
1
IN  
2
3
4
INN  
2
3
4
1
OUT  
5
1
2
3
OUT  
5
2
3
MAON  
No..  
X10  
MAON  
No.  
MAOON  
No..  
X10  
X110  
DC244VV  
IINNPUT  
DC244VV  
IINNPUT  
TESST  
ON  
TEST  
ON  
TEST  
ON  
HEAAD1  
HEAD1  
HEAD1  
1
Item  
HEAD2  
HEAD2  
HEAD2  
2
Host interface  
RS-232C  
2
Possible number of R/W Heads  
Power supply voltage  
4
24 VDC  
Acceptable power supply voltage  
Power consumption  
19.2 to 28.8 VDC  
50 W max.  
Insulation resistance  
20 Mmin. (at 500 VDC) between power supply terminals and frame ground terminals  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 min between power supply terminals and frame ground terminals with a de-  
tected current of10 mA max.  
10 to 50 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 acceleration for 10 sweeps each in X, Y, and Z  
directions  
Vibration resistance  
147 m/s2 3 times each in X, Y, and Z directions  
Shock resistance  
Ambient temperature  
Ambient humidity  
Storage temperature  
Storage humidity  
Ground  
0 to 55°C (with no icing)  
10% to 90% (with no condensation)  
20 to 75°C (with no icing)  
10% to 90% (with no condensation)  
Ground to 100 or less.  
Installed in panel  
Approx. 700 g  
Ground to 100 or less.  
Installed in panel  
Approx. 800 g  
Construction  
Weight  
Electromagnetic Coupling RFID System V600  
9
Transmission Distance Specifications for Battery-less Data Carriers  
with Small Memory Capacity  
Recommended combinations  
Data Carrier R/W Head  
V600-D23P71 V600-H07  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
Stationary Read dis-  
tance  
Irrelevant  
10 to 70 mm (max. axi- These Data Carriers are for installa-  
al offset ±10 mm)  
tion on non-metallic surfaces only.  
Write dis-  
tance  
V600-D23P71/72  
Data Carrier  
R/W Head  
Moving  
Read dis-  
tance  
30 to 60 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Iron  
Non-metallic  
(Resin, plastic, wood, etc.)  
V600-H11/-H11-R  
Stationary Read dis-  
tance  
Irrelevant  
Irrelevant  
Irrelevant  
5 to 40 mm (max. axial  
offset ±10 mm)  
Data transmission will be impossi-  
ble if the DC is installed directly on  
a metal surface. Refer to the V600  
R/W Heads and EEPROM Data  
Carriers Operation Manual (Cat.  
No. Z128) for details.  
Write dis-  
tance  
Moving  
Read dis-  
tance  
15 to 40 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
V600-D23P72 V600-H07  
Stationary Read dis-  
tance  
10 to 50 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Moving  
Read dis-  
tance  
30 to 40 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
V600-H11/-H11-R  
Stationary Read dis-  
tance  
5 to 30 mm (max. axial  
offset ±10 mm)  
Write dis-  
tance  
Moving  
Read dis-  
tance  
15 to 30 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch  
or memory switch only with a Serial-interface Controller or ID Sensor Unit.  
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.  
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.  
10  
Electromagnetic Coupling RFID System V600  
Recommended combinations  
Data Carrier R/W Head  
V600-D23P66N V600-H07  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
5 to 45 mm (max. axial  
R/W Head  
Data Carrier  
Transmission  
time priority  
5 to 35 mm (max. axial  
offset ±10 mm)  
Iron  
Write dis-  
tance  
Irrelevant  
5 to 35 mm (max. axial  
offset ±10 mm)  
Non-metallic  
(Resin, plastic, wood, etc.)  
Moving  
Read dis-  
tance  
Transmission  
distance priority al offset ±10 mm)  
25 to 40 mm (max. axi-  
Data transmission will be impossi-  
ble if the DC is installed directly on  
a metal surface. Refer to the V600  
R/W Heads and EEPROM Data  
Carriers Operation Manual (Cat.  
No. Z128) for details.  
Transmission  
time priority  
25 to 30 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
25 to 30 mm (max. axi-  
al offset ±10 mm)  
V600-H11/-H11-R  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
5 to 30 mm (max. axial  
Transmission  
time priority  
5 to 25 mm (max. axial  
offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
5 to 25 mm (max. axial  
offset ±10 mm)  
Moving  
Read dis-  
tance  
Transmission  
distance priority al offset ±10 mm)  
15 to 25 mm (max. axi-  
Transmission  
time priority  
15 to 20 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
15 to 20 mm (max. axi-  
al offset ±10 mm)  
V600-  
D23P66SP  
V600-H07  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
5 to 40 mm (max. axial  
Transmission  
time priority  
5 to 30 mm (max. axial  
offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
5 to 30 mm (max. axial  
offset ±10 mm)  
Moving  
Read dis-  
tance  
Transmission  
distance priority al offset ±10 mm)  
20 to 40 mm (max. axi-  
Transmission  
time priority  
20 to 30 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
20 to 30 mm (max. axi-  
al offset ±10 mm)  
V600-H11/-H11-R  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
5 to 25 mm (max. axial  
Transmission  
time priority  
5 to 20 mm (max. axial  
offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
5 to 20 mm (max. axial  
offset ±10 mm)  
Moving  
Read dis-  
tance  
Transmission  
distance priority al offset ±10 mm)  
10 to 25 mm (max. axi-  
Transmission  
time priority  
10 to 20 mm (max. axi-  
al offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
10 to 20 mm (max. axi-  
al offset ±10 mm)  
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch  
or memory switch only with a Serial-interface Controller or ID Sensor Unit.  
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.  
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.  
Electromagnetic Coupling RFID System V600  
11  
Recommended combinations  
Data Carrier R/W Head  
V600-D23P61 V600-H11/-H11-R  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
2 to 19 mm (max. axial These Data Carriers can be in-  
stalled on metallic surfaces.  
Transmission  
time priority  
2 to 16 mm (max. axial  
offset ±10 mm)  
V600-D23P61  
Data Carrier  
Write dis-  
tance  
Irrelevant  
2 to 16 mm (max. axial  
offset ±10 mm)  
V600-H51  
R/W Head  
Moving  
Read dis-  
tance  
Transmission  
distance priority al offset ±10 mm)  
12 to 19 mm (max. axi-  
Iron  
Transmission  
time priority  
12 to 16 mm (max. axi-  
al offset ±10 mm)  
Iron (SC, SS)  
V600-H11  
R/W Head  
V600-D23P61  
Data Carrier  
Write dis-  
tance  
Irrelevant  
12 to 16 mm (max. axi-  
al offset ±10 mm)  
V600-H51  
Stationary Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
1 to 16 mm (max. axial  
Iron  
Transmission  
time priority  
1 to 14 mm (max. axial  
offset ±10 mm)  
Iron (SC, SS)  
The listed transmission distances  
also apply for installation on non-  
metallic surfaces. Refer to the V600  
R/W Heads and EEPROM Data  
Carriers Operation Manual (Cat.  
7 to 14 mm (max. axial  
No. Z128) for details.  
Write dis-  
tance  
Irrelevant  
1 to 14 mm (max. axial  
offset ±10 mm)  
Moving  
Read dis-  
tance  
Transmission  
distance priority offset ±10 mm)  
7 to 16 mm (max. axial  
Transmission  
time priority  
offset ±10 mm)  
Write dis-  
tance  
Irrelevant  
7 to 14 mm (max. axial  
offset ±10 mm)  
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch  
or memory switch only with a Serial-interface Controller or ID Sensor Unit.  
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.  
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.  
12  
Electromagnetic Coupling RFID System V600  
Recommended combinations  
Data Carrier R/W Head  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
0.5 to 4.0  
mm (max.  
0.5 to 4.5  
mm (max.  
V600-D23P53 V600-HS51  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority  
These Data Carriers are for flush  
mounting in metallic bases only.  
axial offset axial offset  
±2 mm)  
±1 mm)  
V600-D23P53/54  
Data Carrier  
V600-HS61  
R/W Head  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Transmission  
time priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Write dis-  
tance  
Irrelevant  
axial offset axial offset  
Iron  
±2 mm)  
±1 mm)  
Iron  
(SC, SS)  
0.5 to 4.0  
mm (max.  
0.5 to 4.5  
mm (max.  
V600-HS61  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority  
axial offset axial offset  
V600-D23P53/54  
Data Carrier  
±2 mm)  
±1 mm)  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Transmission  
time priority  
axial offset axial offset  
V600-HS51  
R/W Head  
±2 mm)  
±1 mm)  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Write dis-  
tance  
Irrelevant  
axial offset axial offset  
Iron  
Iron(SC, SS)  
±2 mm)  
±1 mm)  
0.5 to 4.0  
mm (max.  
0.5 to 4.5  
mm (max.  
V600-H52  
Stationary Read dis-  
tance  
Transmission  
distance priority  
V600-D23P53/54  
Data Carrier  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Transmission  
time priority  
V600-H52  
R/W Head  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 3.0  
mm (max.  
0.5 to 3.5  
mm (max.  
Write dis-  
tance  
Irrelevant  
Iron  
Iron(SC, SS)  
axial offset axial offset  
The listed transmission distances  
also apply for installation on non-  
metallic surfaces. Refer to the V600  
R/W Heads and EEPROM Data  
Carriers Operation Manual (Cat.  
No. Z128) for details.  
±2 mm)  
±1 mm)  
0.5 to 6.0  
mm (max.  
0.5 to 6.5  
mm (max.  
V600-D23P54 V600-HS51  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 5.5  
mm (max.  
axial offset axial offset  
±2 mm)  
0.5 to 6.0  
mm (max.  
Transmission  
time priority  
±1 mm)  
0.5 to 5.0  
mm (max.  
0.5 to 5.5  
mm (max.  
Write dis-  
tance  
Irrelevant  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 6.5  
mm (max.  
0.5 to 7.0  
mm (max.  
V600-HS61  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 5.5  
mm (max.  
0.5 to 6.0  
mm (max.  
Transmission  
time priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 5.5  
mm (max.  
0.5 to 6.0  
mm (max.  
Write dis-  
tance  
Irrelevant  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 6.5  
mm (max.  
0.5 to 7.0  
mm (max.  
V600-H52  
Stationary Read dis-  
tance  
Transmission  
distance priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 5.5  
mm (max.  
0.5 to 6.0  
mm (max.  
Transmission  
time priority  
axial offset axial offset  
±2 mm)  
±1 mm)  
0.5 to 5.5  
mm (max.  
0.5 to 6.0  
mm (max.  
Write dis-  
tance  
Irrelevant  
axial offset axial offset  
±2 mm)  
±1 mm)  
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch  
or memory switch only with a Serial-interface Controller or ID Sensor Unit.  
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.  
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.  
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.  
Electromagnetic Coupling RFID System V600  
13  
Recommended combinations  
Data Carrier R/W Head  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
V600-D23P55 V600-HS51  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 6.5 mm (max.  
These Data Carriers are for flush  
mounting in non-metallic bases  
only.  
Transmission  
time priority  
0.5 to 6.0 mm (max.  
axial offset ±2 mm)  
V600-D23P55  
Data Carrier  
Write dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 6.5 mm (max.  
Transmission  
time priority  
0.5 to 6.0 mm (max.  
axial offset ±2 mm)  
V600-HS51  
R/W Head  
V600-HS61  
(See note 4.)  
Stationary Read dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 7.0 mm (max.  
Iron  
Transmission  
time priority  
0.5 to 6.0 mm (max.  
axial offset ±2 mm)  
Non-metallic  
(Resin, plastic, wood, etc.)  
Write dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 7.0 mm (max.  
V600-D23P55  
Data Carrier  
V600-HS61  
R/W Head  
Transmission  
time priority  
0.5 to 6.0 mm (max.  
axial offset ±2 mm)  
V600-H52  
Stationary Read dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 9.0 mm (max.  
Transmission  
time priority  
0.5 to 8.5 mm (max.  
axial offset ±2 mm)  
Iron  
Non-metallic  
(Resin, plastic, wood, etc.)  
Write dis-  
tance  
Transmission  
distance priority axial offset ±2 mm)  
0.5 to 8.5 mm (max.  
Transmission  
time priority  
0.5 to 8.5 mm (max.  
axial offset ±2 mm)  
V600-D23P55  
Data Carrier  
V600-H52  
R/W Head  
Iron  
Non-metallic  
(Resin, plastic, wood, etc.)  
The transmission distance decreas-  
es considerably when flush mount-  
ed in non-metallic bases. Refer to  
the V600 R/W Heads and EEPROM  
Data Carriers Operation Manual  
(Cat. No. Z128) for details.  
Note: 1. The transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting switch  
or memory switch only with a Serial-interface Controller or ID Sensor Unit.  
2. With Parallel-interface Controllers, the mode setting is always transmission distance priority.  
3. The specifications take fluctuations in ambient temperature and slight differences between products into account.  
4. This is the transmission distance when using the V600-HS@1 and V600-HA51 combination.  
14  
Electromagnetic Coupling RFID System V600  
Transmission Distance Specifications for Data Carriers with Large  
Memory Capacity (Built-in-battery/Battery-less/Replaceable-battery)  
Recommended combinations  
Data Carrier R/W Head  
V600-D8KR12 V600-H07  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
Stationary Flush-mount- Irrelevant  
ed in metal  
10 to 50 mm (max. axi-  
al offset ±10 mm)  
R/W Head  
Metal  
Surface-  
mounted on  
metal  
10 to 60 mm (max. axi-  
al offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
25 to 50 mm (max. axi-  
al offset ±10 mm)  
Data Carrier  
Surface-mounted on metal  
Surface-  
mounted on  
metal  
25 to 60 mm (max. axi-  
al offset ±10 mm)  
Metal  
V600-H11  
Stationary Flush-mount- Irrelevant  
ed in metal  
5 to 40 mm (max. axial  
offset ±10 mm)  
Surface-  
mounted on  
metal  
5 to 45 mm (max. axial  
offset ±10 mm)  
Data Carrier  
Flush-mounted in metal  
Moving  
Flush-mount-  
ed in metal  
25 to 40 mm (max. axi-  
al offset ±10 mm)  
Metal  
Surface-  
mounted on  
metal  
25 to 45 mm (max. axi-  
al offset ±10 mm)  
The listed transmission distances  
also apply for installation on non-  
metallic surfaces. Refer to the V600  
R/W Heads and SRAM Data Carri-  
ers Operation Manual (Cat. No.  
Z127) for details.  
V600-D8KR13 V600-H07  
Stationary Flush-mount- Irrelevant  
ed in metal  
10 to 30 mm (max. axi-  
al offset ±10 mm)  
Surface-  
mounted on  
metal  
10 to 35 mm (max. axi-  
al offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
20 to 30 mm (max. axi-  
al offset ±10 mm)  
Surface-  
mounted on  
metal  
20 to 35 mm (max. axi-  
al offset ±10 mm)  
V600-H11  
Stationary Flush-mount- Irrelevant  
ed in metal  
10 to 30 mm (max. axi-  
al offset ±10 mm)  
Surface-  
mounted on  
metal  
Moving  
Flush-mount-  
ed in metal  
15 to 30 mm (max. axi-  
al offset ±10 mm)  
Surface-  
mounted on  
metal  
Electromagnetic Coupling RFID System V600  
15  
Recommended combinations  
Data Carrier R/W Head  
Installation  
Controller  
mode  
Transmission  
distance  
Condition for DC and R/W head  
installation  
V600-D8KR04 V600-H07  
(unsealed)  
Stationary Flush-mount- Irrelevant  
ed in metal  
See note1.  
The listed transmission distances  
also apply for installation on non-  
metallic surfaces. Refer to the V600  
R/W Heads and SRAM Data Carri-  
ers Operation Manual (Cat. No.  
Z127) for details.  
Surface-  
mounted on  
metal  
10 to 100 mm (max.  
axial offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
50 to 100 mm (max.  
axial offset ±10 mm)  
V600-H11  
V600-D8KF04 V600-H07  
V600-H11  
Stationary Flush-mount- Irrelevant  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
10 to 65 mm (max. axi-  
al offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
30 to 65 mm (max. axi-  
al offset ±10 mm)  
Stationary Flush-mount- Irrelevant  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
10 to 50 mm (max. axi-  
al offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
25 to 50 mm (max. axi-  
al offset ±10 mm)  
Stationary Flush-mount- Irrelevant  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
10 to 32 mm (max. axi-  
al offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
See note1.  
Surface-  
mounted on  
metal  
15 to 32 mm (max. axi-  
al offset ±10 mm)  
V600-D2KR16 V600-H11  
Stationary Flush-mount- Irrelevant  
ed in metal  
2 to 15 mm (max. axial  
offset ±10 mm) (See  
note 2.)  
Surface-  
mounted on  
metal  
2 to 15 mm (max. axial  
offset ±10 mm)  
Moving  
Flush-mount-  
ed in metal  
6 to 15 mm (max. axial  
offset ±10 mm) (See  
note 2.)  
Surface-  
mounted on  
metal  
10 to 15 mm (max. axi-  
al offset ±10 mm)  
Note: 1. When Data Carriers are flush-mounted in metal, the read/  
write distance will depend on the distance (x) between the  
side of the DC and the metal surface.  
2. Use the following method for flush mounting into a metallic  
base.  
10 mm min.  
10 mm min.  
Flush-mounted  
mm  
mm  
Flush-mounted  
Refer to the V600 R/W  
Heads and SRAM Data  
Carriers Operation Manual  
(Cat. No. Z127) for details.  
Metal  
20 mm max.  
Metal  
16  
Electromagnetic Coupling RFID System V600  
Influence of Surrounding Metal  
V600-D8KR04 Combined with V600-H07  
V600-D8KR04 Combined with V600-H11  
(Axial offset: ±0 mm)  
(Axial offset: ±0 mm)  
100  
80  
60  
40  
100  
R/W Head  
Data Carrier  
R/W Head  
Data Carrier  
50  
20  
0
0
20  
40  
60  
80  
20  
40  
60  
80  
(Above 100)  
Distance from metal surface ( ) (mm)  
(Above 100)  
Distance from metal surface ( ) (mm)  
V600-D8KF04 Combined with V600-H07  
V600-D8KF04 Combined with V600-H11  
(Axial offset: ±0 mm)  
70  
(Axial offset: ±0 mm)  
70  
60  
50  
40  
30  
60  
50  
40  
30  
R/W Head  
Data Carrier  
R/W Head  
Data Carrier  
20  
10  
20  
10  
0
20  
40  
60  
80  
100  
0
20  
40  
60  
80  
100  
(Above 100)  
(Above 100)  
Distance from metal surface ( ) (mm)  
Distance from metal surface ( ) (mm)  
Electromagnetic Coupling RFID System V600  
17  
Lower-level Communications Mode Setting (Distance/Time Priority)  
The lower-level communications mode is set with the DIP Switch or memory switch on the Serial-interface Controller (V600-CA5D02, V600-CD1D-  
V3, V600-CM1D) or ID Sensor Unit. (Refer to the Controller’s operation manual for more details on the setting.)  
Characteristic Data (Typical)  
Transmission Range  
Note: The values shown in the following graphs are in millimeters. Refer to pages 10 to 16 for details on Data Carrier and R/W Head mounting  
conditions.  
Battery-less Data Carriers with Small Memory Capacity  
V600-D23P71 & V600-H07  
V600-D23P71 & V600-H11  
Y
Y
Y
Y
80  
100  
80  
60  
40  
20  
X
60  
40  
20  
X
120 100 80 60 40 20  
0
20 40 60 80 100 120  
X
–100 –80 –60 –40 –20  
0
20  
40  
60  
80 100 X  
V600-D23P72 & V600-H07  
V600-D23P72 & V600-H11  
Y
Y
Y
Y
60  
100  
80  
60  
40  
20  
X
X
40  
20  
120  
100  
80  
60  
40  
20  
0
20 40 60 80 100 120  
X
–80  
–60  
–40  
–20  
0
20  
40  
60  
80  
80  
80  
40  
X
X
X
X
V600-D23P66N & V600-H07  
V600-D23P66N & V600-H11  
Y
Y
Y
Y
60  
80  
X
X
60  
40  
20  
40  
20  
80  
60  
40  
20  
0
20  
40  
40  
20  
60  
100 80 60 40 20  
0
20  
40  
40  
20  
60  
60  
30  
80 100 X  
V600-D23P66SP & V600-H07  
V600-D23P66SP & V600-H11  
Y
Y
Y
Y
80  
60  
X
60  
40  
20  
X
40  
20  
100 80 60 40 20  
0
20  
80 100 X  
80  
60  
40  
20  
0
20  
60  
Y
V600-D23P61 & V600-H11  
V600-D23P61 & V600-H51  
Y
Y
Y
40  
30  
X
X
30  
20  
10  
20  
10  
50 40 30 20 10  
0
10  
40  
50  
X
40  
30  
20  
10  
0
10  
30  
Write range (in transmission distance or transmission time priority mode)  
Read range (in transmission time priority mode)  
Read range (in transmission distance priority mode)  
18  
Electromagnetic Coupling RFID System V600  
V600-D23P53 & V600-HS51  
+V600-HA51  
V600-D23P53 & V600-HS61  
+V600-HA51  
V600-D23P53 & V600-H52  
Y
Y
Y
Y
Y
Y
10  
10  
10  
X
X
X
5
5
5
10  
5  
0
5
10 X  
10  
5  
0
5
10  
X
10  
5  
0
5
10 X  
V600-D23P54 & V600-HS51  
+V600-HA51  
V600-D23P54 & V600-HS61  
+V600-HA51  
V600-D23P54 & V600-H52  
Y
Y
Y
Y
Y
Y
15  
15  
15  
X
X
X
10  
5
10  
5
10  
5
X
15  
10  
5  
0
5
10  
15  
15  
10  
5  
0
5
10  
15  
X
15  
10  
5  
0
5
10  
15  
X
V600-D23P55 & V600-HS51  
+V600-HA51  
V600-D23P55 & V600-HS61  
+V600-HA51  
V600-D23P55 & V600-H52  
Y
Y
Y
Y
Y
Y
15  
15  
15  
10  
5
X
X
X
10  
5
10  
5
15  
10  
5  
0
5
10  
15  
X
15  
10  
5  
0
5
10  
15  
X
15  
10  
5  
0
5
10  
15  
X
Write range (in transmission distance or transmission time priority mode)  
Read range (in transmission time priority mode)  
Read range (in transmission distance priority mode)  
Electromagnetic Coupling RFID System V600  
19  
Built-in-battery Data Carriers with Large Memory Capacity  
V600-D8KR12 & V600-H07  
V600-D8KR12 & V600-H11  
Y
Y
Y
Y
80  
60  
X
X
60  
40  
20  
40  
20  
–100 –80 –60 –40 –20  
0
20  
40  
60  
80 100 X  
80  
60  
40  
20  
0
20  
40  
60  
80 X  
V600-D8KR13 & V600-H07  
V600-D8KR13 & V600-H11  
Y
Y
Y
Y
80  
60  
X
X
60  
40  
20  
40  
20  
100 80 60 40 20  
0
20  
40  
60  
80 100 X  
80  
60  
40  
20  
0
20  
40  
60  
80 X  
V600-D8KR04 & V600-H07  
V600-D8KR04 & V600-H11  
Y
Y
Y
Y
120  
80  
X
X
60  
40  
20  
80  
40  
160  
120  
80  
40  
0
40  
80  
120  
160 X  
100 80 60 40 20  
0
20  
40  
60  
80 100 X  
Battery-less Data Carriers with Large Memory Capacity  
V600-D8KF04 & V600-H07  
V600-D8KF04 & V600-H11  
Y
Y
Y
Y
80  
80  
X
X
60  
40  
20  
60  
40  
20  
100 80 60 40 20  
0
20  
40  
60  
80 100 X  
100 80 60 40 20  
0
20  
40  
60  
80 100 X  
Replaceable-battery Data Carriers with Large Memory Capacity  
V600-D2KR16 & V600-H11  
Y
Y
60  
X
40  
20  
80  
60  
40  
20  
0
20  
40  
60  
80 X  
Read/Write range (in transmission distance or transmission time priority mode)  
20  
Electromagnetic Coupling RFID System V600  
Communications Time  
The communications time does not depend on the model of R/W  
Head or Data Carrier, although communications times differ  
between Data Carriers with and without batteries.  
The lower-level communications time does not include the host  
communications; it is the time required for communications  
between the R/W Head and Data Carrier. The lower-level commu-  
nications time is used in the equation for the DC speed.  
The turn around time (TAT) is the total time required from the issu-  
ance of a command from the host device (for example, a host com-  
puter) until the reception of a response.  
DC Speed = (Distance travelled in the transmission range)/  
(Lower-level communications time)  
RDH1……………*  
Command  
RD001122……………*  
Response  
Lower-level communications time  
TAT (Turn Around Time)  
Lower-level Communications Time with  
Built-in-battery Data Carriers (Reference)  
1,000  
Lower-level Communications Time with  
Battery-less Data Carriers (Reference)  
(Battery-less Models Excluding V600-  
D8KF04)  
2,500  
800  
Transmission distance priority mode  
Transmission time priority mode  
(Auto) Write  
600  
2,000  
(Auto) Write  
1,500  
400  
1,000  
200  
0
(Auto) Read  
(Auto) Read  
500  
1
50  
100  
150  
200  
250 300  
Number of bytes  
0
50  
100  
150  
200  
250 300  
Calculation (Reference)  
Number of bytes  
Lower-level communications time  
(ms)  
Calculation (Reference)  
R/W  
READ  
t = 1.8 N + 48.4  
t = 4.2 N + 86.5  
Lower-level communications  
time (ms)  
WRITE  
N is the number of processing bytes.  
Distance  
priority mode  
READ  
WRITE  
READ  
WRITE  
t = 4.3 N + 64.6  
t = 8.7 N + 167.1  
t = 1.8 N + 79.0  
t = 7.1 N + 180.4  
V600-D8KF04 (Battery-less)  
1,000  
Time priority  
mode  
N is the number of processing bytes.  
800  
600  
(Auto)Write  
400  
200  
0
(Auto)Read  
1
50  
100  
150  
200  
250 300  
Number of bytes  
Calculation (Reference)  
Lower-level communications time  
(ms)  
READ  
t = 1.8 N + 168.4  
t = 4.2 N + 206.5  
WRITE  
N is the number of processing bytes.  
Electromagnetic Coupling RFID System V600  
21  
Battery Life  
The Data Carrier has a built-in lithium battery.  
The following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, and the battery life.  
V600-D8KR12 (Typical Example)  
V600-D8KR04 (Typical Example)  
V600-D8KR13 (Typical Example)  
5 years  
5 years  
5 years  
8 years  
8 years  
8 years  
Number of bytes/transmission  
Number of bytes/transmission  
Number of bytes/transmission  
Temperature and Battery Life  
V600-D2KR16  
The battery life is two years at 25°C regardless of the relationship between the number of bytes read/written and the number of transmissions.  
Examples Showing Relationship between Battery Life and Temperature  
The following table shows the standard values.  
2.5  
Temperature  
20°C  
Battery consumption rate in one year  
1%  
2%  
2
1.5  
1
30°C  
40°C  
50°C  
60°C  
4%  
8%  
16%  
32%  
70°C  
Note: If the battery is stored at 70°C and is not installed, the battery  
0.5  
life is calculated as follows:  
2 (years) × (1 - 0.32) = 1.36 years  
If the battery is stored at 25°C after one year’s storage, the bat-  
tery life will be approximately 1 year and 4 months. (The battery  
life will be shortened if the battery is used at temperatures close  
to 0°C or 50°C.)  
0
10  
20  
30  
40  
50  
Ambient temperature (˚C)  
The values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). If the battery is not installed, the  
values shown in the above table will apply.  
22  
Electromagnetic Coupling RFID System V600  
Precautions  
Data Carrier Batteries  
Built-in-battery Data Carriers  
Replaceable-battery Data Carriers  
WARNING  
WARNING  
The SRAM-type Data Carrier has a built-in lithium  
battery which may occasionally ignite, explode, and  
burn if mishandled. Do not disassemble, deform,  
heat above 212°F (100°C), or incinerate the Data  
Carrier.  
The SRAM-type Data Carrier has replaceable lithium  
batteries which may occasionally take fire, explode,  
burn, or leak liquid if mishandled. Do not deform,  
heat above 212°F (100°C), incinerate, or charge the  
batteries, or short-circuit their positive and negative  
terminals.  
Mutual Interference (Reference Values)  
Mutual Interference between R/W Heads  
When more than one set of R/W Heads are used, mutual interference between the Heads can be avoided by mounting the Heads at the specified  
distance as shown below.  
V600-H07  
V600-H11  
Facing  
Facing  
RD/WT command: 650 mm min.  
Auto command: 900 mm min.  
RD/WT command: 200 mm min.  
Auto command: 200 mm min.  
650 mm min.  
200 mm min.  
(900 mm min.)  
Side-by-side  
Side-by-side  
RD/WT command: 550 mm min.  
Auto command: 1,200 mm min.  
RD/WT command: 200 mm min.  
Auto command: 200 mm min.  
200 mm min.  
550 mm min.  
(1,200 mm min.)  
Electromagnetic Coupling RFID System V600  
23  
V600-H51  
V600-H52  
V600-HS51  
Facing: 120 mm min.  
Facing: 80 mm min.  
Facing: 80 mm min.  
V600-H51  
V600-H51  
V600-H52  
V600-H52  
V600-HS51  
V600-HS51  
80 mm min.  
120 mm min.  
80 mm min.  
Side-by-side: 100 mm min.  
Side-by-side: 80 mm min.  
Side-by-side: 80 mm min.  
80 mm min.  
80 mm min.  
100 mm min.  
V600-HS51  
V600-HS51  
V600-H51  
V600-H51  
V600-H52  
V600-H52  
V600-HS61  
Facing: 80 mm min.  
Side-by-side: 80 mm min.  
V600-HS61  
V600-HS61  
V600  
V600  
-HS61  
-HS61  
80 mm min.  
80 mm min.  
Note: If the two R/W Heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. Therefore, the  
restriction on the distance between the Heads will not be applicable.  
The commands will be received by the R/W Heads and transmission will oscillate between them.  
Mutual Interference between Proximity Sensors  
The V600-series Units use electromagnetic coupling (frequency: 530 kHz). When a V600 Unit is wired close to R/W Heads, Proximity Switches,  
and Sensors that have an oscillating frequency between 400 and 600 kHz, the Proximity Sensor may malfunction, so be sure to install the Units  
according to the distance restrictions specified in the following diagrams. Make sure to thoroughly test that the mounting positions and the fixed  
positions of the Sensors are correct before putting them into actual operation.  
Facing: 300 mm min.  
V600-H07  
Vertical/Parallel: 400 mm min.  
300 mm min.  
V600-H07  
Proximity Sensor  
Proximity Sensor  
400 mm min.  
400 mm min.  
Proximity Sensor  
V600-H07  
24  
Electromagnetic Coupling RFID System V600  
Facing: 100 mm min.  
V600-H11  
Vertical/Parallel: 100 mm min.  
100 mm min.  
V600-H11  
Proximity Sensor  
Proximity Sensor  
100 mm min.  
100 mm min.  
V600-H11  
Proximity Sensor  
V600-H51/H52  
V600-HS51  
V600-HS61  
100 mm min.  
V600-HS61  
Proximity Sensor  
Proximity Sensor  
Proximity Sensor  
100 mm min.  
100 mm min.  
Proximity Sensor  
Proximity Sensor  
Proximity Sensor  
V600-HS51  
V600-H51/52  
200 mm min.  
200 mm min.  
100 mm min.  
100 mm min.  
150 mm min.  
150 mm min.  
Proximity Sensor  
Proximity Sensor  
V600-HS61  
Proximity Sensor  
Electromagnetic Coupling RFID System V600  
25  
Mutual Interference between Data Carriers  
When more than one Data Carrier is used, mutual interference between the DCs can be avoided by making sure that they are mounted apart at  
the distances specified below.  
Reading/Writing  
V600-D23P53  
V600-D23P54  
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +  
V600-HA51  
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +  
V600-HA51  
40 mm min.  
45 mm min.  
V600-D23P55  
V600-D23P61  
R/W Head: V600-H11/-H51  
R/W Head: V600-H52, V600-HS51 + V600-HA51, V600-HS61 +  
V600-HA51  
50 mm min.  
90 mm min.  
V600-D23P66N  
R/W Head: V600-H11  
V600-D23P66SP  
R/W Head: V600-H11  
140 mm min.  
140 mm min.  
R/W Head: V600-H07  
R/W Head: 600-H07  
160 mm min.  
160 mm min.  
V600-D23P72  
R/W Head: V600-H11  
R/W Head: V600-H07  
210 mm min.  
170 mm min.  
180 mm min.  
140 mm min.  
V600-D23P71  
R/W Head: V600-H07  
290 mm min.  
210 mm min.  
26  
Electromagnetic Coupling RFID System V600  
V600-D8KR12  
R/W Head: V600-H11  
R/W Head: V600-H07  
140 mm min.  
160 mm min.  
140 mm min.  
160 mm min.  
V600-D8KR13  
R/W Head: V600-H11  
R/W Head: V600-H07  
160 mm min.  
180 mm min.  
160 mm min.  
160 mm min.  
V600-D8KR04/V600-D8KF04  
R/W Head: V600-H11  
R/W Head: V600-H07  
220 mm min.  
180 mm min.  
180 mm min.  
V600-D2KR16  
R/W Head: V600-H11  
150 mm min.  
90 mm min.  
Electromagnetic Coupling RFID System V600  
27  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Data Carriers with Large Memory Capacity  
Built-in-battery DCs  
V600-D8KR12  
V600-D8KR13  
65  
86  
0.2  
55±  
Two, 4.5-dia. mounting holes  
10  
5
10  
27  
Two, 4.5-dia. mounting holes  
10  
27  
10  
0.2  
54 44±0.2  
40 30±  
76±0.2  
Case: ABS resin  
Filler: Epoxy resin  
5
15  
8
Case: ABS resin  
Filler: Epoxy resin  
10.3  
5
V600-D8KR04  
86  
31  
5
Four, 4.5-dia. mounting holes  
0.2  
5
76±  
0.2  
54 44±  
Case: ABS resin  
Filler: Epoxy resin  
20  
10  
Replaceable-battery DCs  
V600-D2KR16  
4-R1.5  
65  
40  
R0.5  
Case: ABS resin  
5
Battery-less DCs  
V600-D8KF04  
86  
31  
Four, 4.5-dia. mounting holes  
0.2  
5
5
76±  
0.2  
54 44±  
20  
Case: ABS resin  
Filler: Epoxy resin  
10  
28  
Electromagnetic Coupling RFID System V600  
Data Carriers with Small Memory Capacity  
Battery-less DCs  
V600-D23P53  
V600-D23P54  
V600-D23P55  
V600-D23P61  
36  
0.1  
30±  
24  
0
R0.3  
12 – 0.2dia.  
R0.2  
R0.2  
0
0
8
– 0.1dia.  
8
– 0.1dia.  
24  
2-R1.0  
0
Two, 3.5-dia. mounting holes  
0
5 – 0.1  
5 – 0.1  
0
6 – 0.2  
6
2.2  
Case: ABS resin  
Filler: Epoxy resin  
Case: ABS resin  
Filler: Epoxy resin  
Case: PPS resin  
Filler: Epoxy resin  
Case: ABS resin  
Filler: Epoxy resin  
V600-D23P66N  
V600-D23P66SP  
Mounting Hole Dimensions  
2-M3  
Two, 5.5-dia.  
mounting holes  
4-R6  
Mounting Hole Dimensions  
2-M5  
34  
4-R4  
0.2  
25±  
4-R3  
34  
36.5  
0.2  
0.2  
80±  
0.2  
25±  
25±  
34 32  
Two, 3.5-dia.  
Two, 6-dia.  
Coating: PFA resin  
0.2  
6.5  
25±  
1.3  
0.1  
32  
34  
3.5±  
0.2  
80±  
2.5 max.  
Case: PPS resin  
95  
V600-D23P71  
V600-D23P72  
4-R2  
4-R2  
50  
86  
34  
54  
Case: Glass epoxy resin  
Coating: Polyurethane resin  
1.5  
Case: Glass epoxy resin  
Coating: Polyurethane resin  
1.5  
Electromagnetic Coupling RFID System V600  
29  
R/W Heads  
V600-H07  
Four, 4.5-dia.  
mounting holes  
100  
0.2  
90±  
5
5
50  
50  
Power indicator  
(green)  
25  
43  
100  
90±  
14.7 dia.  
0.2  
Transmission  
indicators  
(orange)  
Vinyl-insulated Connector  
round cord  
(6-mm dia.)  
Bushing  
10  
Case: ABS resin  
Filler: Epoxy resin  
Cable: PVC (oil-resistant)  
14  
10  
30  
20  
11  
V600-H11  
Vinyl-insulated round cord (6-mm dia.)  
Connector  
4-R1  
28  
Two, 4.5-dia. mounting holes  
Bushing  
2-R5  
Accessories: Two brackets  
for rear panel mounting  
10  
40  
14.7 dia.  
43  
5
Case: ABS resin  
Filler: Epoxy resin  
Cable: PVC (oil-resistant)  
5
27  
6
5
13  
18  
Power (green)/transmission  
(orange) indicators  
53  
20  
23  
11  
V600-H51  
V600-H52  
80  
(72)  
(66)  
62.5  
85  
(77)  
(71)  
67.5  
12  
7
43  
43  
12 dia.  
14.7 dia.  
14.7 dia.  
19.8 dia.  
Connector  
Connector  
Vinyl-insulated round cord (6-mm dia.)  
Vinyl-insulated round cord (6-mm dia.)  
M22X1  
2 lock washers  
M22X1  
Power (green)/transmission (orange) indicators  
Power (green)/transmission (orange) indicators  
2 lock nuts  
2 lock washers  
2 lock nuts  
Case: Brass  
Transmission window: ABS resin  
Filler: Epoxy resin  
Case: Brass  
Transmission window: ABS resin  
Filler: Epoxy resin  
Cable: PVC (oil-resistant)  
Cable: PVC (oil-resistant)  
V600-HS51 (Sensor Section)  
V600-HS61 (Sensor Section)  
2 lock washers  
Vinyl-insulated round cord  
(4-mm dia.)  
30.5  
4.5  
8.5  
2 lock nuts  
M12X1  
18  
Connector  
49.5  
0.1  
12±  
9.6 dia.  
13.7 dia.  
18  
13.7 dia.  
7
Connector  
49.5  
Transmission surface  
Two, 3.5x5  
mounting holes  
33  
35  
Vinyl-insulated round cord  
(4-mm dia.)  
Case: Brass  
Transmission window: ABS resin  
Filler: Epoxy resin  
Case: ABS resin  
Filler: Epoxy resin  
10  
Cable: PVC (oil-resistant)  
6.5  
Cable: PVC (oil-resistant)  
30  
Electromagnetic Coupling RFID System V600  
V600-HA51 (Amplifier Section)  
Operating indicator (orange)  
Power indicator (green)  
12.8 dia.  
22.6 22  
51.7  
5.9  
61.8  
5
(10,000)  
43  
Connector  
13.7 dia.  
8
14.7 dia.  
36.5  
23.5  
Case: ABS resin  
Filler: Epoxy resin  
Cable: PVC (oil-resistant)  
Vinyl-insulated round cord  
6-mm dia (7/0.18-mm dia.),  
8-conductor cable  
Connector  
0.2  
51.3±  
4
6.1  
35.6  
Two, 4.5-dia. mounting holes  
13.2  
ID Controllers  
V600-CA5D02 (Compact)  
Two, 4.5-dia.  
mounting holes  
105  
95  
80  
5
65  
18  
90  
80  
17.5  
5
7.5  
V600-CD1D-V3 (Compact)  
18  
68  
53  
17.5  
50  
5.5  
81  
92  
80  
Two, 4.5-dia.  
115  
V600-CM1D (Board-mounted)  
102  
92  
78  
76  
9
16.5  
21.5  
5
6
57.4  
95  
86.3  
107  
Four, 3.5-dia.  
R/W Head connector  
Electromagnetic Coupling RFID System V600  
31  
Accessories  
Holder  
V600-A81  
68  
0.1  
8-R0.5  
40±  
0.1  
24±  
20  
42  
(Four, 3.5-dia.)  
(Four, 5.5-dia.)  
Case: ABS resin  
2-R2.5  
9
3.5  
V600-A84  
Use M3 countersunk screws in the two 3.2-dia.  
mounting holes or apply ultrasonic welding.  
0.5  
99.8±  
8.5  
5
4-R3  
2.1  
24.4  
42.5  
0.5  
67.8±  
63.6  
2.1  
2.1  
2.1  
95.6  
Attachment  
V600-A86  
Material: PPS resin  
Two, 4-dia.  
4-R5.5  
0.2  
25±  
0.2  
34 15  
16  
37  
25±  
15  
34  
37  
4
3.5  
10  
Mounting Hole Dimensions  
2-M3  
0.2  
25±  
0.2  
25±  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
32  
Electromagnetic Coupling RFID System V600  
READ AND UNDERSTAND THIS DOCUMENT  
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.  
WARRANTY  
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of  
sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS  
FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT  
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY  
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S  
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO  
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
SUITABILITY FOR USE  
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF  
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate  
catalogs for OMRON's safety rated products.  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use  
of the product.  
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This  
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other  
application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the  
products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,  
and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A  
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED  
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PERFORMANCE DATA  
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of  
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of  
Liability.  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some  
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your  
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or  
proofreading errors, or omissions.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This document shall not be copied for sales or promotions without permission.  
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in  
any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.  
Cat. No. Q124-E1-03  
2007.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2007 All Rights Reserved.  

相关型号:

V600-D23P66SP

Analog Circuit
OMRON

V600-D23P71

Analog Circuit
OMRON

V600-D23P72

Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems
OMRON

V600-D2KR16

Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems
OMRON

V600-D8KF04

Non-contact Data Communications System
OMRON

V600-D8KR04

Innovative RFID Electronic Flags to Replace Mechanical Flag and Kanban Systems
OMRON

V600-D8KR12

Analog Circuit
OMRON

V600-D8KR13

Analog Circuit
OMRON

V600-D8KR16

Analog Circuit
OMRON

V600-H07

Non-contact Data Communications System
OMRON

V600-H07(2M)

Analog Circuit
OMRON

V600-H11

Non-contact Data Communications System
OMRON