Y92P-48GM [OMRON]

Solid-state Multi-functional Timer;
Y92P-48GM
型号: Y92P-48GM
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Solid-state Multi-functional Timer

文件: 总22页 (文件大小:401K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HSoli3d-sCtateRMu-ltiA-functional Timer  
DIN 48 x 48-mm State-of-the-art  
Multifunctional Timer  
A wider power supply range reduces the number of timer mod-  
els kept in stock.  
A wide range of applications through six or four operating  
modes.  
Reduced power consumption.  
(Except for H3CR-A8E)  
Enables easy sequence checks through instantaneous outputs  
for a zero set value at any time range.  
Length, when panel-mounted with a Socket, of 80 mm or less.  
Time Setting Rings enable consistent settings and limit the set-  
ting range.  
Panel Covers enable various panel designs.  
PNP input models available.  
Rich variety of inputs: Start, reset, and gate functions (11-pin  
models and -AP models)  
Model Number Structure  
Model Number Legend  
H3CR-A@@@-@  
1 2 3  
4
1. Number of Pins  
3. Output  
None: Relay output (DPDT)  
None: 11-pin models  
8: 8-pin models  
2. Input Type for 11-pin Models  
S:  
E:  
Transistor output (NPN/PNP universal use)  
Relay output (SPDT) with instantaneous relay output (SP-  
DT)  
None: No-voltage input (NPN type)  
4. Suffix  
P:  
Voltage input (PNP type)  
300: Dual mode models (signal ON/OFF-delay and one-shot)  
301: Double time scale (range) models (0.1 s to 600 h)  
Solid-state Multi-functional Timer H3CR-A  
B-109  
Ordering Information  
List of Models  
11-pin Models  
Output  
Supply voltage  
Input type  
Time range  
Operating mode (see  
note 2)  
Model  
Contact  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
No-voltage input  
0.05 s to 300 h  
Six multi-modes: A, B, H3CR-A  
B2, C, D, E  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
Dual-modes: G, J  
H3CR-A-300  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
Voltage input  
Six multi-modes: A, B, H3CR-AP  
B2, C, D, E  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
No-voltage input  
0.1 s to 600 h  
0.05 s to 300 h  
H3CR-A-301  
H3CR-AS  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
Transistor (Photocou- 24 to 48 VAC (50/60 Hz)/  
pler)  
12 to 48 VDC  
8-pin Models  
Output  
Supply voltage  
Input type  
Time range  
Operating mode (see  
note 2)  
Model  
H3CR-A8  
Contact  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
No-input available 0.05 s to 300 h  
Four multi-modes: A,  
B2, E, J  
(Power supply start)  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
100 to 240 VAC (50/60 Hz)/  
100 to 125 VDC  
0.1 s to 600 h  
H3CR-A8-301  
24 to 48 VAC (50/60 Hz)/  
12 to 48 VDC  
Transistor (Photocou- 24 to 48 VAC (50/60 Hz)/  
pler) 12 to 48 VDC  
0.05 s to 300 h  
H3CR-A8S  
H3CR-A8E  
Time-limit contact and 100 to 240 VAC (50/60 Hz)/  
instantaneous contact 100 to 125 VDC  
24 to 48 VDC/VAC (50/60 Hz)  
Note: 1. Specify both the model number and supply voltage when ordering.  
Example: H3CR-A 100 to 240 VAC (50/60 Hz)/100 to 125 VDC  
Supply voltage  
2. The operating modes are as follows  
A: ON-delay  
D: Signal OFF-delay  
E: Interval  
G: Signal ON/OFF-delay  
J: One-shot  
B: Flicker OFF start  
B2: Flicker ON start  
C: Signal ON/OFF-delay  
B-110  
Solid-state Multi-functional Timer H3CR-A  
Accessories (Order Separately)  
Name/specifications  
Models  
Flush Mounting Adapter  
Y92F-30  
Y92F-73  
Y92F-74  
PFP-50N  
PFP-100N  
PFP-100N2  
PFP-M  
Mounting Track  
50 cm (l) x 7.3 mm (t)  
1 m (l) x 7.3 mm (t)  
1 m (l) x 16 mm (t)  
End Plate  
Spacer  
PFP-S  
Protective Cover  
Y92A-48B  
P2CF-08  
P2CF-08-E  
P2CF-11  
P2CF-11-E  
P3G-08  
Track Mounting/  
Front Connecting Socket  
8-pin  
8-pin, finger safe type  
11-pin  
11-pin, finger safe type  
8-pin  
Back Connecting Socket  
8-pin, finger safe type  
11-pin  
P3G-08 with Y92A-48G (see note 1)  
P3GA-11  
11-pin, finger safe type  
Setting a specific time  
Limiting the setting range  
Light gray (5Y7/1)  
Black (N1.5)  
P3GA-11 with Y92A-48G (see note 1)  
Time Setting Ring  
Y92S-27  
Y92S-28  
Panel Cover (see note 2)  
Y92P-48GL  
Y92P-48GB  
Y92P-48GM  
Y92H-7  
Medium gray (5Y5/1)  
For PL08 and PL11 Sockets  
For PF085A Socket  
Hold-down Clip (see note 3)  
Y92H-8  
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket.  
2. The Time Setting Ring and Panel Cover are sold together.  
3. Hold-down Clips are sold in sets of two.  
Specifications  
General  
Item  
H3CR-A/-AS  
A: ON-delay  
H3CR-AP  
H3CR-A8/-A8S  
H3CR-A8E  
Operating mode  
A: ON-delay (power supply start)  
B: Flicker OFF start  
B2: Flicker ON start  
C: Signal ON/OFF-delay  
D: Signal OFF-delay  
E: Interval  
B2: Flicker ON start (power supply start)  
E: Interval (power supply start)  
J: One-shot (power supply start)  
G: Signal ON/OFF-delay (Only for H3CR-A-300)  
J: One-shot (Only for H3CR-A-300)  
Pin type  
11-pin  
8-pin  
---  
Input type  
No-voltage input  
Voltage input  
Time-limit output type H3CR-A/-A8/-AP:Relay output (DPDT)  
H3CR-AS/-A8S: Transistor output (NPN/PNP universal)*  
---  
Relay output (SPDT)  
Relay output (SPDT)  
Instantaneous output  
type  
Mounting method  
DIN track mounting, surface mounting, and flush mounting  
Approved standards  
UL508, CSA C22.2 No.14, NK, Lloyds  
Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2.  
Output category according to EN60947-5-1 for Timers with Contact Outputs.  
Output category according to EN60947-5-2 for Timers with Transistor Outputs.  
*The internal circuits are optically isolated from the output. This enables universal application as NPN or PNP transistor.  
Solid-state Multi-functional Timer H3CR-A  
B-111  
Time Ranges  
Note: When the time setting knob is turned below 0until the point where the time setting knob stops, the output will operate instantaneously at  
all time range settings.  
Standard (0.05-s to 300-h) Models  
Time unit  
s (sec)  
min (min)  
0.12 to 1.2  
h (hrs)  
x10 h (10 h)  
1.2 to 12  
Full scale set- 1.2  
0.05 to 1.2  
0.3 to 3  
ting  
3
3 to 30  
12  
30  
1.2 to 12  
3 to 30  
12 to 120  
30 to 300  
Double (0.1-s to 600-h) Models  
Time unit  
s (sec)  
min (min)  
0.24 to 2.4  
h (hrs)  
x10 h (10 h)  
Full scale set- 2.4  
0.1 to 2.4  
0.6 to 6  
2.4 to 24  
6 to 60  
2.4 to 24  
6 to 60  
ting  
6
24  
60  
24 to 240  
60 to 600  
Ratings  
Rated supply voltage (see note 1)  
100 to 240 VAC (50/60 Hz)/100 to 125 VDC, 24 to 48 VAC (50/60 Hz)/12 to 48 VDC (24 to 48 VAC/VDC for H3CR-  
A8E) (see note 2)  
Operating voltage range  
Power reset  
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)  
Minimum power-opening time: 0.1 s  
No-voltage Input  
Input  
ON impedance:  
ON residual voltage:  
OFF impedance:  
Voltage Input  
1 kmax.  
1 V max.  
100 kmin.  
Max. permissible capacitance between inputs lines (terminals 6 and 7): 1,200 pF  
Load connectable in parallel with inputs (terminals 6 and 7).  
100 to 240 VAC/100 to 125 VDC  
High (logic) level: 85 to 264 VAC/85 to 137.5 VDC  
Low (logic) level:  
0 to 10 VAC/0 to 10 VDC  
24 to 48 VAC/12 to 48 VDC  
High (logic) level: 20.4 to 52.8 VAC/10.8 to 52.8 VDC  
Low (logic) level:  
0 to 2.4 VAC/0 to 1.2 VDC  
Power consumption  
H3CR-A/-A8  
100 to 240 VAC/100 to 125 VDC  
(When at 240 VAC, 60 Hz)  
Relay ON: approx. 2.0 VA (1.6 W)  
24 to 48 VAC/12 to 48 VDC  
(When at 24 VDC)  
Relay OFF: approx. 1.3 VA (1.1 W)  
Relay OFF: approx. 0.2 W  
Relay ON: approx. 0.8 W  
H3CR-AP (see note 3)  
100 to 240 VAC/100 to 125 VDC  
(When at 240 VAC, 60 Hz)  
Relay ON: approx. 2.5 VA (2.2 W)  
Relay OFF: approx. 1.8 VA (1.7 W)  
Relay OFF: approx. 0.3 W  
24 to 48 VAC/12 to 48 VDC  
(When at 24 VDC)  
Relay ON: approx. 0.9 W  
H3CR-A8E  
100 to 240 VAC/100 to 125 VDC  
(When at 240 VAC, 60 Hz)  
Relay ON/OFF: approx. 2 VA (0.9 W)  
24 to 48 VAC/VDC  
(When at 24 VDC)  
Relay ON/OFF: approx. 0.9 W  
H3CR-AS/-A8S  
24 to 48 VAC/12 to 48 VDC  
(When at 24 VDC)  
Output ON: 0.3 W Output OFF: 0.2 W  
Control outputs  
Time limit contacts:  
Transistor output:  
5 A at 250 VAC/30 VDC, 0.15 A at 125 VDC, resistive load (cosφ = 1)  
Open collector (NPN/PNP), 100 mA max. at 30 VDC max.,  
residual voltage: 2 V max.  
5 A at 250 VAC/30 VDC, 0.15 A at 125 VDC, resistive load (cosφ = 1)  
Instantaneous contact:  
Note: 1. DC ripple rate: 20% max. if the power supply incorporates a single-phase, full-wave rectifier.  
2. Each 24-to-48-VAC/12-to-48-VDC model causes an inrush current of approximately 0.85 A. Pay careful attention when attempting to turn  
ON power to such a model with non-contact output from a device such as a sensor.  
3. The values are for when the terminals 2 and 7 and terminals 10 and 6 are short-circuited, and include the consumption current of the  
input circuit.  
B-112  
Solid-state Multi-functional Timer H3CR-A  
Characteristics  
Accuracy of operating 0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)  
time  
Setting error  
Reset time  
5% FS 50 ms (see note 1)  
Min. power-opening time: 0.1 s max.  
Min. pulse width:  
0.05 s (H3CR-A/-AS)  
Reset voltage  
10% max. of rated supply voltage  
Influence of voltage  
0.2% FS max. ( 0.2% 10 ms max. in a range of 1.2 s)  
1% FS max. ( 1% 10 ms max. in a range of 1.2 s)  
Influence of tempera-  
ture  
Insulation resistance 100 Mmin. (at 500 VDC)  
Dielectric strength  
2,000 VAC (1,000 VAC for H3CR-A@S), 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-  
current-carrying metal parts)  
2,000 VAC (1,000 VAC for H3CR-A@S), 50/60 Hz for 1 min (between control output terminals and operating circuit)  
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)  
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)  
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit) for H3CR-AP  
Impulse withstand  
voltage  
3 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC  
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC/100 to  
125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and 24 to 48 VAC/VDC  
Noise immunity  
Static immunity  
Vibration resistance  
Shock resistance  
1.5 kV (between power terminals) and 600 V (between no-voltage input terminals), square-wave noise by noise sim-  
ulator (pulse width: 100 ns/1 µs, 1-ns rise)  
Malfunction: 8 kV  
Destruction: 15 kV  
Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each  
Malfunction: 10 to 55 Hz with 0.5-mm single amplitude each in 3 directions for 10 minutes each  
Destruction: 1,000 m/s2 3 times each in 6 directions  
Malfunction: 100 m/s2 3 times each in 6 directions  
Ambient temperature Operating: 10°C to 55°C (with no icing)  
Storage: 25°C to 65°C (with no icing)  
Ambient humidity  
Life expectancy  
Operating: 35% to 85%  
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)  
Electrical:  
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) (see note 2)  
EMC  
(EMI)  
EN61812-1  
Emission Enclosure:  
Emission AC Mains:  
(EMS)  
EN55011 Group 1 class A  
EN55011 Group 1 class A  
EN61812-1  
Immunity ESD:  
IEC61000-4-2:  
6 kV contact discharge (level 3)  
8 kV air discharge (level 3)  
Immunity RF-interference from AM Radio Waves:  
IEC61000-4-3:10 V/m (80 MHz to 1 GHz) (level 3)  
Immunity RF-interference from Pulse-modulated Radio Waves:IEC61000-4-3:10 V/m (900 5 MHz) (level 3)  
Immunity Conducted Disturbance: IEC61000-4-6:  
10 V (0.15 to 80 MHz) (level 3)  
2 kV power-line (level 3)  
Immunity Burst:  
IEC61000-4-4:  
2 kV I/O signal-line (level 4)  
1 kV line to line (level 3)  
Immunity Surge:  
IEC61000-4-5:  
2 kV line to ground (level 3)  
Case color  
Light gray (Munsell 5Y7/1)  
IP40 (panel surface)  
Approx. 90 g  
Degree of protection  
Weight  
Note: 1. The value is 5% FS +100 ms to 0 ms max. when the C, D, or G mode signal of the H3CR-AP is OFF.  
2. Refer to the Life-test Curve.  
Solid-state Multi-functional Timer H3CR-A  
B-113  
Life-test Curve  
10,000  
5,000  
1,000  
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosφ = 1)  
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In  
both cases, a life of 100,000 operations can be expected.  
The minimum applicable load is 10 mA (100 mA for H3CR-A8E) at  
5 VDC (failure level: P).  
30 VDC L/R = 7 ms  
500  
250 VAC/30 VDC  
(cosφ = 1)  
100  
250 VAC (cosφ = 0.4)  
Load current (A)  
B-114  
Solid-state Multi-functional Timer H3CR-A  
Connections  
Block Diagrams  
H3CR-A/AS  
Zero setting  
detection  
circuit  
AC (DC) input  
Time range/  
unit selectors  
Operating  
mode selector  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Reset input, start input, and gate input  
Input circuit  
Power-ON Output-ON  
indicator indicator  
H3CR-AP  
Zero setting  
detection  
circuit  
Time range/  
unit selectors  
Operating  
mode selector  
AC (DC) input  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Input circuit  
Start  
Power-ON Output-ON  
indicator  
indicator  
Solid-state Multi-functional Timer H3CR-A  
B-115  
H3CR-A8/A8S  
Zero setting  
detection  
circuit  
Time range/  
unit selectors  
Operating  
mode selector  
AC (DC) input  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Power-ON Output-ON  
indicator indicator  
H3CR-A8E  
Zero setting  
detection  
circuit  
Time range/  
unit selectors  
Operating  
mode selector  
AC (DC) input  
Power supply  
circuit  
Oscillation  
circuit  
Counting  
circuit  
Output circuit  
Indicator  
circuit  
Power-ON Output-ON  
indicator  
indicator  
Instantaneous  
output circuit  
I/O Functions  
Inputs (for -A/ Start  
Starts time-measurement.  
-AS models)  
Reset  
Interrupts time-measurement and resets time-measurement value. No time-measurement is made and  
control output is OFF while the reset input is ON.  
Gate  
Prohibits time-measurement.  
Outputs  
Control output  
Outputs are turned ON according to designated output mode when preset value is reached.  
Note: H3CR-AP incorporates start input only.  
B-116  
Solid-state Multi-functional Timer H3CR-A  
Terminal Arrangement  
Note: The delayed contact of conventional Timers was indicated as  
The contact symbol of the H3CR-A is indicated as  
because its operating mode is six multi-modes (four multi-modes for the H3CR-A8).  
11-pin Models  
8-pin Models  
H3CR-A/-A-300/-A-301 (Contact Output)  
H3CR-A8/-A8-301 (Contact Output)  
Power supply  
H3CR-A8S (Transistor Output)  
Power supply  
H3CR-AS (Transistor Output)  
Power supply  
Note: Terminals 1, 3, 4, and 5 are empty. Terminals 2 and 7 are the  
same as for the H3CR-A8.  
H3CR-A8E (Contact Output)  
Power supply  
Note: Terminals 1, 3, 4, and 8 are empty. Terminals 2, 5, 6, 7, and 10  
are the same as for the H3CR-A.  
H3CR-AP (Contact Output)  
Power supply  
Power supply  
Note: Terminal 5 is empty.  
Solid-state Multi-functional Timer H3CR-A  
B-117  
Input Connections  
H3CR-A/-AS  
The inputs of the H3CR-A/-AS are no-voltage (short-circuit or open) inputs.  
No-voltage Inputs  
No-contact Input  
Contact Input  
No-contact Input  
(Connection to NPN open  
collector output sensor.)  
(Connection to a voltage  
output sensor.)  
12 to 24 VDC  
(sensor power supply)  
12 to 24 VDC  
(sensor power supply)  
+
DC power  
supply  
+
DC power  
supply  
Timer  
Timer  
Timer  
Sensor  
Sensor  
5 Gate  
6 Start  
7 Reset  
5 Gate  
6 Start  
7 Reset  
5
6
7
Gate  
Start  
Reset  
2 Input (0 V)  
2
Input (0 V)  
2
Input (0 V)  
Operates with relay ON  
Operates with transistor ON  
Operates with transistor ON  
No-voltage Input Signal Levels  
No-contact 1. Short-circuit level  
input  
Transistor ON  
Residual voltage: 1 V max.  
Impedance when ON: 1 kmax.  
2. Open level  
Transistor OFF  
Impedance when OFF: 100 kmin.  
Contact  
input  
Use contacts which can adequate-  
ly switch 0.1 mA at 5 V  
B-118  
Solid-state Multi-functional Timer H3CR-A  
H3CR-AP  
The start input of the H3CR-AP is voltage input. (Voltage imposition or open)  
Voltage Inputs  
No-contact Input  
No-contact Input  
Contact Input  
(Connection to PNP open  
collector output sensor)  
(Connection to NPN open  
collector output sensor)  
12 to 24 VDC  
12 to 24 VDC  
(sensor power supply)  
(sensor power supply)  
DC power  
supply  
DC power  
supply  
+
+
Sensor  
Sensor  
Timer  
Timer  
Timer  
10 Power  
10 Power  
10 Power  
supply (+)  
supply (+)  
supply (+)  
6
Start  
6
Start  
6
Start  
7
2
Input 0V  
7
2
Input 0V  
7
2
Input 0V  
Power  
supply  
()  
Power  
supply  
()  
Power  
supply  
()  
Operates with relay ON  
Operates with PNP transistor ON  
Operates with NPN transistor ON  
Note: The input circuit is isolated from the Note: Refer to the signal levels in the fol-  
power supply circuit. Thus, an NPN  
lowing table and be aware of the  
transistor can be connected.  
minimum applicable load of the relay.  
Voltage Input Signal Levels  
No-contact 1. Transistor ON  
input  
Residual voltage: 1 V max.  
The voltage between terminals 6 and 7 must be 10.8 VDC min.  
2. Transistor OFF  
Leakage current: 0.01 mA max.  
The voltage between terminals 6 and 7 must be 1.2 VDC max.  
Contact  
input  
Use contacts that can adequately switch 0.1 mA at each oper-  
ating voltage.  
The voltage between terminals 6 and 7 with contacts ON or  
OFF must satisfy the specified value.  
Contacts ON  
100-to-240-VAC and 100-to-125-VDC models: 85 to 264 VAC  
or 85 to 137.5 VDC  
24-to-48-VAC and 12-to-48-VDC models: 20.4 to 52.8 VAC or  
10.8 to 52.8 VDC  
Contacts OFF  
100-to-240-VAC and 100-to-125-VDC models: 0 to 10 VAC or  
0 to 10 VDC  
24-to-48-VAC and 12-to-48-VDC models: 0 to 2.4 VAC or 0 to  
1.2 VDC  
Solid-state Multi-functional Timer H3CR-A  
B-119  
Operation  
Timing Chart  
Note: 1. The minimum power-opening time (Rt) is 0.1 s.  
2. The minimum input pulse width (for start, reset) is 0.05 s.  
3. The letter tin the timing charts stands for the set time and tameans that the period is less than the time set.  
4. Power supply start in mode J is also possible for H3CR-A8/-A8E/-A8S/-A8-301 models.  
H3CR-A/-AS/-AP*  
*H3CR-AP model incorporates start input only.  
Operating  
mode  
Timing chart  
A: ON-delay  
t
t
Basic operation  
Power  
Start  
Power  
Start  
(see note)  
Reset  
t
Output relay (NC)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is invalid while the  
Timer is in operation.  
Power indicator  
B:  
Basic operation  
Flicker OFF  
start  
Power  
Start  
Power  
Start  
(see note)  
Reset  
t
t
t
t
Output relay (NC)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is invalid while  
Power indicator  
the Timer is in operation.  
B2:  
Flicker ON  
start  
Basic operation  
Power  
Start  
Power  
Start  
(see note)  
Reset  
t
t
t
t
Output relay (NC)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is invalid while the  
Timer is in operation.  
Power indicator  
C:  
Basic operation  
Signal ON/  
OFF-  
delay  
Power  
Start  
Power  
Start  
(see note)  
Reset  
t
t
t
t
Output relay (NC)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is valid and re-  
triggerable while the Timer is  
in operation.  
Power indicator  
B-120  
Solid-state Multi-functional Timer H3CR-A  
Operating  
mode  
Timing chart  
D:  
Basic operation  
Signal OFF-  
delay  
Power  
Start  
Power  
Start  
Reset  
(see note)  
t
Output relay (NC)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is valid and  
re-triggerable while the  
Timer is in operation.  
Power indicator  
E:  
Interval  
Basic operation  
Power  
Start  
Power  
Start  
(see note)  
Output  
t
Reset  
Output relay (NC)  
Output relay (NO)  
(Output indicator)  
Note: Start input is valid and  
re-triggerable while  
the Timer is in opera-  
tion.  
Power indicator  
G:  
Basic operation  
Signal ON/  
OFF-  
delay  
Power  
Start  
Power  
Start  
Reset  
(see note)  
Output  
t
t
t
t
Output relay (NC)  
Output relay (NO)  
(Output indicator)  
Note: Start input is valid and re-triggera-  
ble while the Timer is in operation.  
Power indicator  
J:  
Basic operation  
One-shot out-  
put  
Power  
Start  
Power  
Reset  
Start  
(see note)  
1 0.6 s  
(Fixed)  
t
Output relay (NC)  
1 0.6 s  
(Fixed)  
1 0.6 s  
(Fixed)  
Output  
Output relay (NO)  
(Output indicator)  
Note: Start input is valid and re-  
triggerable while the Timer  
is in operation.  
Power indicator  
Gate Signal Input  
t
1
t
2
ON  
OFF  
Power  
ON  
Start  
Gate  
OFF  
ON  
OFF  
ON  
OFF  
Reset  
Output  
relay  
ON  
OFF  
Note: 1. This timing chart indicates the gate input in op-  
erating mode A (ON-delay operation).  
2. The set time is the sum of t1 and t2.  
3. H3CR-AP model incorporates start input only.  
Solid-state Multi-functional Timer H3CR-A  
B-121  
H3CR-A8/-A8S  
Operating  
mode  
Timing chart  
A:  
ON-delay  
Power  
Basic operation  
Output relay  
(NC)  
Power  
Output relay  
(NO) (output  
indicator)  
t
Output  
Power  
indicator  
B2:  
Flicker ON  
start  
Power  
Basic operation  
Output relay  
(NC)  
Power  
t
Output relay  
(NO) (output  
indicator)  
t
t
t
Output  
Power  
indicator  
E:  
Interval  
Power  
Basic operation  
Output relay  
(NC)  
Power  
Output relay  
(NO) (output  
indicator)  
t
Output  
Power  
indicator  
J:  
One-shot out-  
put  
Power  
Basic operation  
Output relay  
(NC)  
1 0.6 s  
(Fixed)  
1 0.6 s  
(Fixed)  
Power  
Output relay  
(NO) (output  
indicator)  
1 0.6 s  
(Fixed)  
t
Output  
Power  
indicator  
Note: 1. The minimum power-opening time (Rt) is 0.1 s.  
2. The letter tin the timing charts stands for the set time and tameans that the period is less than the time set.  
B-122  
Solid-state Multi-functional Timer H3CR-A  
H3CR-A8E  
Operating  
mode  
Timing chart  
A:  
ON-delay  
Power  
Output relay  
(NC)  
Output relay  
(NO) (output  
indicator)  
Basic operation  
Instantaneous  
output relay (NC)  
Power  
t
Instantaneous  
output relay (NO)  
Output  
Power indicator  
B2:  
Flicker ON  
start  
Power  
Output relay  
(NC)  
Basic operation  
Output relay  
(NO) (output  
indicator)  
Power  
Instantaneous  
output relay (NC)  
t
t
t
t
Output  
Instantaneous  
output relay (NO)  
Power indicator  
E:  
Interval  
Power  
Output relay  
(NC)  
Output relay  
(NO) (output  
indicator)  
Basic operation  
Instantaneous  
output relay (NC)  
Power  
Instantaneous  
output relay (NO)  
t
Output  
Power indicator  
J:  
One-shot out-  
put  
Power  
Output relay  
(NC)  
Output relay  
(NO) (output  
indicator)  
(Fixed)  
(Fixed)  
Basic operation  
Instantaneous  
output relay (NC)  
Power  
Instantaneous  
output relay (NO)  
t
1 0.6 s  
(Fixed)  
Output  
Power indicator  
Note: 1. The minimum power-opening time (Rt) is 0.1 s.  
2. The letter tin the timing charts stands for the set time and tameans that the period is less than the time set.  
Solid-state Multi-functional Timer H3CR-A  
B-123  
Nomenclature  
Power indicator (green) (Flashes when Timer  
operates; lit when Timer stops operating)  
Operating mode display window  
Operating mode selector  
Select a mode from:  
Output indicator (orange)  
(Lit when output)  
A, B, B2, C, D, and E (H3CR-A, -AP, and -AS)  
A, B2, E and J (H3CR-A8, -A8S, and -A8E) G  
and J (H3CR-A-300)  
Scale range display windows  
Time unit display window  
Time range selector (select one  
from 1.2, 3, 12, and 30 at full  
scale; with the H3CR-A@-301,  
select from 2.4, 6, 24, or 60 at  
full scale. )  
Time unit selector (select one  
from sec, min, hrs, and 10h)  
Time setting  
knob (set time)  
B-124  
Solid-state Multi-functional Timer H3CR-A  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
H3CR-A  
H3CR-AP  
H3CR-AS  
15  
66.6  
52.3  
6
48  
0.7  
39 dia.  
44.8 x 44.8  
48  
11 pins  
H3CR-A8  
H3CR-A8S  
H3CR-A8E  
15  
66.6  
52.3  
6
0.7  
48  
39 dia.  
44.8 x 44.8  
48  
8 pins  
Dimensions with Set Ring  
16.5  
50  
42 dia.  
50  
Time Setting  
Ring  
Panel cover  
Dimensions with Front Connecting Socket  
P2CF-08-@/P2CF-11-@  
Dimensions with Back Connecting Socket  
P3G-08/P3GA-11  
81.5  
75  
81.5  
80  
15  
15  
H3CR-A  
H3CR-AS  
H3CR-AP  
H3CR-A8@  
H3CR-A  
H3CR-AS  
H3CR-AP  
+
H3CR-A8@  
+
Adapter  
98.5  
89.9*  
87.6  
100.8  
*
Adapter  
P3G-08  
P3GA-11  
Y92F-30  
Y92F-30  
(When  
Y92A-48G  
mounted)  
(When  
Y92A-48G  
mounted)  
2.3  
*
P2CF-11  
P2CF-11-E  
P2CF-08  
P2CF-08-E  
2.3  
*
*These dimensions vary with the kind of DIN track (reference value).  
Solid-state Multi-functional Timer H3CR-A  
B-125  
Application Examples (H3CR-A)  
A Mode: ON-delay  
ON-delay operation (A mode) is a basic mode.  
1. Power-ON Start/Power-OFF Reset  
The Power-ON start/Power-OFF reset operation is a standard oper-  
ating method.  
3. Control of Integrated Time with Gate  
Signal  
With a gate signal, the Power-ON start operation and Signal start  
operation can be controlled (the operation can be interrupted).  
t
Power (2 and 10)  
t
1
t1 + t2: set time  
t
2
Power (2 and 10)  
Start (2 and 6)  
Start (2 and 6)  
Reset (2 and 7)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Gate (2 and 5)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Power indicator  
Control output: NO (9 and 11)  
NO (1 and 3)  
Flashing  
Lit  
Power indicator  
Externally short-circuited  
Flashing  
Lit  
Gate signal (The operation is interrupted with the  
gate signal if the Timer detects an abnormal signal.)  
Externally  
short-circuited  
Power  
supply  
Power  
supply  
2. Signal Start/Signal Reset  
The Signal start/Signal reset operation is useful for remote control of  
the Timer.  
B/B2 Mode: Flicker  
The flicker operation in the B and B2 modes can be effectively  
applied to lamp or buzzer (ON and OFF) alarms or the monitoring of  
an intermittent operation with a display.  
Power (2 and 10)  
Start (2 and 6)  
1. Power-ON Start/Power-OFF Reset (in B  
Mode)  
Reset (2 and 7)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Power (2 and 10)  
Power indicator  
Start (2 and 6)  
Lit  
Flashing  
Lit  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Start signal (remote control possible)  
Reset signal  
(remote control possible)  
Power indicator  
Flashing  
Externally short-circuited  
Power  
supply  
(Power continuously supplied)  
Power  
supply  
B-126  
Solid-state Multi-functional Timer H3CR-A  
2. Signal Start/Signal Reset (in B Mode)  
If there is an abnormal signal, flashing starts. When the abnormal  
condition is restored, a reset signal stops the display flashing.  
2. Signal-ON-OFF Start/Instantaneous  
Operation/Time-limit Reset  
t
t
Power (2 and 10)  
Start (2 and 6)  
Power (2 and 10)  
Start (2 and 6)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Reset (2 and 7)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Power indicator  
Control output: NO (9 and 11)  
NO (1 and 3)  
Power indicator  
Lit  
Flashing  
Lit  
Start signal  
(The operation starts with the signal ON or OFF)  
Start signal  
Reset signal  
Power  
supply  
Power  
supply  
(Power continuously supplied)  
(Power continuously supplied)  
D Mode: Signal OFF-delay  
Signal OFF-delay operation (D mode) can be effectively used to keep  
a load operating for a certain period. For example, this function  
enables the cooling fan for a lamp or heater to operate for a certain  
period after the lamp or heater is switched OFF.  
C Mode: Signal ON/OFF-delay  
The Signal ON-/OFF-delay operation (C mode) is useful for the con-  
trol of distribution of products on a production line into boxes by the  
specified number or time.  
1. Power-ON Start/Instantaneous Operation/  
Time-limit Reset  
1. Power-ON Start/Instantaneous Operation/  
Time-limit Reset  
A set of these functions is useful for the operation of a machine for a  
specified period when power is ON.  
Power (2 and 10)  
Start (2 and 6)  
Power (2 and 10)  
Start (2 and 6)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Power indicator  
Lit  
Flashing  
Control output: NO (9 and 11)  
NO (1 and 3)  
Lit  
Start signal (NC to NO)  
Externally short-circuited  
Power  
supply  
Power  
supply  
Solid-state Multi-functional Timer H3CR-A  
B-127  
2. Signal Start/Instantaneous Operation/  
Time-limit Reset  
2. Signal Start/Instantaneous Operation/  
Time-limit Reset  
This function is useful for the repetitive control such as the filling of  
liquid for a specified period after each Signal start input.  
Power (2 and 10)  
Start (2 and 6)  
t
t
Power (2 and 10)  
Start (2 and 6)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Power indicator  
Control output: NO (9 and 11)  
NO (1 and 3)  
Lit  
Flashing  
Lit  
Start signal (NO to NC to NO)  
Start signal  
Power  
supply  
Power  
supply  
(Power continuously supplied)  
(Power continuously supplied)  
E Mode: Interval  
1. Power-ON Start/Instantaneous Operation/  
Time-limit Reset  
This function is useful for the operation of a machine for a specified  
period after power is ON.  
Power (2 and 10)  
Start (2 and 6)  
Control output: NC (8 and 11)  
NC (1 and 4)  
Control output: NO (9 and 11)  
NO (1 and 3)  
Externally short-circuited  
Power  
supply  
B-128  
Solid-state Multi-functional Timer H3CR-A  
Precautions (H3CR-A)  
Note: The undermentioned is common for all H3CR-A models.  
Power Supplies  
Input/Output  
For the power supply of an input device of the H3CR-A@/-A@S/-AP,  
use an isolating transformer with the primary and secondary wind-  
ings mutually isolated and the secondary winding not grounded.  
Relationship between Input and Power  
Supply Circuits (except for H3CR-A8E)  
Example: H3CR-A  
The H3CR-A (except for H3CR-A8E) uses transformerless power  
supply. When connecting a relay or transistor as an external signal  
input device, pay attention to the following points to prevent short-cir-  
cuiting due to a sneak current to the transformerless power supply. If  
a relay or transistor is connected to two or more Timers, the input ter-  
minals of those Timers must be wired properly so that they will not  
differ in phase, otherwise the terminals will be short-circuited to one  
another.  
H3CR-A  
G, S, R  
10  
2
5, 6, 7  
Input  
terminal  
Power supply  
2
Short-circuit current  
Incorrect  
H3CR-A  
Contact or transistor for  
external input signal  
Isolation transformer is required.  
Input device  
Input  
terminal  
Power supply  
The H3CR-A@/-A@S/APs power supply terminal 2 is a common ter-  
minal for input signals to the Timer. Do not disconnect the wires on  
terminal 2, otherwise the internal circuitry of the Timer will be dam-  
aged.  
Input  
terminal  
10  
5, 6, 7  
G, S, R  
Input terminal  
H3CR-A  
Correct  
Input  
terminal  
2
Power supply  
Make sure that the voltage is applied within the specified range, oth-  
erwise the internal elements of the Timer may be damaged.  
Input  
terminal  
It is impossible to provide two independent power switches as shown  
below regardless of whether or not the Timers are different in phase.  
Input  
Power supply  
terminal  
Input  
terminal  
Solid-state Multi-functional Timer H3CR-A  
B-129  
If a relay or transistor is connected to two or more Timers, the input  
terminals of those Timers must be wired properly so that they will not  
be different in phase or the terminals will be short-circuited to one  
another (refer to the figures below).  
Relationship between Input and Power  
Supply Circuits (H3CR-A@/-A@S)  
An appropriate input is applied to the input signal terminals of the  
H3CR-A@/-A@S when one of the input terminals is short-circuited  
with the common terminal (terminal 2) for the input signals. Never  
use terminal 10 as the common terminal for this purpose, otherwise  
the internal circuit of the Timer will be damaged.  
Contact or transistor for  
external input signal  
Incorrect  
10  
6
Incorrect  
H3CR-AP  
2
Power supply  
7
10  
H3CR-A  
AC or DC  
5, 6, 7  
power supply  
G, S, R  
10  
H3CR-AP  
2
Input terminal  
2
6
Short-circuit current  
7
Correct  
10  
5, 6, 7  
G, S, R  
Contact or transistor for  
external input signal  
Correct  
Input terminal  
H3CR-A  
10  
AC or DC  
power supply  
6
2
Power supply  
H3CR-AP  
7
2
Do not connect a relay or any other load between input terminals,  
otherwise the internal circuit of the Timer will be damaged due to the  
high-tension voltage applied to the input terminals.  
Short-circuit current  
10  
6
7
10  
H3CR-AP  
Ry  
H3CR-A  
AC or DC  
power supply  
5, 6, 7  
G, S, R  
2
Input terminal  
2
Input  
contact  
Common to All H3CR-A Models  
With the H3CR-AP, input wires must be as short as possible. If the  
floating capacity of wires exceeds 1,200 pF (approx. 10 m for cables  
with 120 pF/m), the operation will be affected. Pay particular atten-  
tion when using shielded cables.  
Relationship between Input and Power  
Supply Circuits (H3CR-AP)  
The H3CR-A@S transistor output is isolated from the internal cir-  
cuitry by a photocoupler. Therefore, either NPN or PNP output is  
possible.  
H3CR-AP  
AC/DC  
power  
supply  
Power supply  
circuit  
Input circuit  
Since the input circuit and the power supply circuit are configured  
independently, the input circuit can be turned ON or OFF irrespective  
of the ON/OFF state of the power supply.  
It must be noted that a voltage equivalent to the power supply voltage  
is applied to the input circuit.  
B-130  
Solid-state Multi-functional Timer H3CR-A  

相关型号:

Y92S-29

Digital Timer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-29-ND

Digital Timer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-32

Total Counter/Time Counter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-32-ND

Total Counter/Time Counter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-35

Mechatronic Analog Timer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-35-ND

Mechatronic Analog Timer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-36

Compact Economical Totalizer with High Visibility Available with Backlit LCD Display

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-37

Compact Economical Totalizer with High Visibility Available with Backlit LCD Display

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-38

LOCK KEY PEN FOR H3DS RELAYS

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S-41-200

This Compact Cam Positioner, Popular for Its Ease-of-use, Now Comes with Even Better Functions.

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S29

Digital Timer

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON

Y92S32

Total Counter/Time Counter

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
OMRON