NCP1205P2G [ONSEMI]
Single Ended PWM Controller Featuring QR Operation and Soft Frequency Foldback; 单端PWM控制器配备的QR操作和软频率折返型号: | NCP1205P2G |
厂家: | ONSEMI |
描述: | Single Ended PWM Controller Featuring QR Operation and Soft Frequency Foldback |
文件: | 总17页 (文件大小:268K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NCP1205
Single Ended PWM
Controller Featuring QR
Operation and Soft
Frequency Foldback
The NCP1205 combines a true Current Mode Control modulator
and a demagnetization detector to ensure full Discontinuous
Conduction Mode in any load/line conditions and minimum drain
voltage switching (Quasi−Resonant operation, also called critical
conduction operation). With its inherent Variable Frequency Mode
(VFM), the controller decreases its operating frequency at constant
peak current whenever the output power demand diminishes.
Associated with automatic multiple valley switching, this unique
architecture guarantees minimum switching losses and the lowest
power drawn from the mains when operating at no−load conditions.
Thus, the NCP1205 is optimal for applications targeting the newest
International Energy Agency (IEA) recommendations for standby
power.
http://onsemi.com
MARKING
DIAGRAM
8
PDIP−8
N SUFFIX
CASE 626
1205P
AWL
YYWWG
8
1
1
14
PDIP−14
P SUFFIX
CASE 646
The internal High−Voltage current source provides a reliable
NCP1205P2
AWLYYWWG
14
16
charging path for the V capacitor and ensures a clean and short
CC
startup sequence without deteriorating the efficiency once off.
The continuous feedback signal monitoring implemented with an
Overcurrent fault Protection circuitry (OCP) makes the final design
rugged and reliable. The PDIP−14 offers an adjustable version of the
OVP threshold via an external resistive network.
1
1
16
SOIC−16
D SUFFIX
CASE 751B
NCP1205DG
AWLYWW
Features
• Natural Drain Valley Switching for Lower EMI and Quasi−Resonant
Operation (QR)
1
1
• Smooth Frequency Foldback for Low Standby and Minimum Ripple
A
= Assembly Location
= Wafer Lot
= Year
= Work Week
= Pb−Free Package
at Light−Load
WL
YY, Y
WW
G
• Adjustable Maximum Switching Frequency
• Internal 200 ns Leading Edge Blanking on Current Sense
• 250 mA Sink and Source Driver
• Wide Operating Voltages: 8.0 to 30 V
• Wide UVLO Levels: 7.2 to 15 V Typical
• Auto−Recovery Internal Short−Circuit Protection (OCP)
• Integrated 3.0 mA Typ Startup Source
• Current Mode Control
• Adjustable Overvoltage Level
• Pb−Free Packages are Available*
ORDERING INFORMATION
†
Device
Package
Shipping
NCP1205P
PDIP−8
50 Units/Rail
50 Units/Rail
NCP1205PG
PDIP−8
(Pb−Free)
NCP1205P2
PDIP−14
25 Units/Rail
25 Units/Rail
Applications
• High Power AC/DC Adapters for Notebooks, etc.
• Offline Battery Chargers
NCP1205P2G
PDIP−14
(Pb−Free)
• Power Supplies for DVD, CD Players, TVs, Set−Top Boxes, etc.
• Auxiliary Power Supplies (USB, Appliances, etc.)
NCP1205DR2
SOIC−16 2500/Tape & Reel
NCP1205DR2G
SOIC−16 2500/Tape & Reel
(Pb−Free)
†For information on tape and reel specifications,
including part orientation and tape sizes, please
refer to our Tape and Reel Packaging Specifications
Brochure, BRD8011/D.
*For additional information on our Pb−Free strategy and soldering details, please
download the ON Semiconductor Soldering and Mounting Techniques
Reference Manual, SOLDERRM/D.
© Semiconductor Components Industries, LLC, 2006
1
Publication Order Number:
October, 2006 − Rev. 7
NCP1205/D
NCP1205
PIN CONNECTIONS
HV
NC
NC
16
1
2
3
4
5
6
7
15 NC
HV
NC
NC
1
2
3
4
5
6
7
14
14
V
NC
Demag
FB
13 V
CC
CC
Drive
Isense
GND
NC
13
12
11
10
9
Demag
FB
Drive
Isense
GND
NC
12
11
10
9
HV
Demag
FB
V
CC
1
2
3
4
8
7
6
5
Drive
Isense
GND
Ct
Ct
OVP
NC
OVP
NC
Ct
NC
8
NC
8
PDIP−14
PDIP−8
SOIC−16
PIN FUNCTION DESCRIPTION
Pin No.
PDIP−8 PDIP−14 SOIC−16
Pin Name
Function
Startup rail
Description
Connected to the rectified HV rail, this pin provides a
1
2
3
4
1
3
4
5
1
4
5
6
HV
charging path to V bulk capacitor.
CC
Demag
FB
Zero primary−current
detection
This pin ensures the restart of the main switcher when
operating in free−run.
Feedback signal to
control the PWM
This level modulates the peak current level in free−running
operation and modulates the frequency in VFM operation.
Ct
Timing capacitor
By adding a capacitor from Ct to the ground, the user selects
the minimum/maximum operating frequency.
5
10
6
11
7
GND
OVP
The IC’s ground
−
NA
Overvoltage input
By applying a 2.8 V typical level on this pin, the IC is
permanently latched−off until V falls below UVLO .
CC
L
6
7
8
11
12
13
12
13
14
Isense
Drv
The primary−current
sensing pin
This pin senses the primary current via an external shunt
resistor.
This pin drives the
external switcher
The IC is able to deliver or absorb 250 mA peak currents
while delivering a clamped driving signal.
V
CC
Powers the IC
A positive voltage up to 30 V maximum can be applied upon
this pin before the IC stops.
1. PDIP−14 has different pinouts. Please see Pin Connections.
2. Pin 2, 7, 8, 9 and 14 are nonconnected on PDIP−14.
3. Pin 2, 3, 8, 9, 10, 15 and 16 are nonconnected on SOIC−16.
http://onsemi.com
2
NCP1205
R2 D2
150 1N4148
D6
L2
+
+
1N5819
10 mH
C1
C14
5 V
22 mF
10 mF
C10
+
+
C11
470 mF
4x1N4007
10 V
100 mF
10 V
R5
15
* R10
15 k
D7
5.1 V
R8
22 k
M2
MTD1N60E
R4
10
1
2
8
7
6
5
Universal Input
IC4
NCP1205P
3
4
SFH6156−2
R1
560
C12
1 nF
R6
4.7 k
R3
3.3
C13
1.5 nF Y1
* Please refer to the application information section regarding this element.
Figure 1. Typical Application Example for PDIP−8 Version
+
R2 D2
C1
10 mF
15
1N4148
D6
1N5819
L2
10 mH
+
C14
5 V
33 mF/35 V
* R10
15 k
C10
4x1N4007
+
+
C11
470 mF
10 V
47 mF
10 V
R5
15
NCP1205P2
R8
22 k
D7
4.3 V
M2
1
2
3
4
5
6
7
14
13
12
11
10
9
MTD1N60E
IC4
R4
6.8
Universal Input
SFH6156−2
R1
560
8
R6
2.7 k
R3
3.3
C12
1 nF
* Please refer to the application information section regarding this element.
Figure 2. Typical Application Example for PDIP−14 Version
http://onsemi.com
3
NCP1205
Startup
UVLO = 15 V
H
HV
1
2
3
4
8
7
6
5
V
CC
UVLO = 7.2 V
L
Last Pulse of Demag
Internal V
CC
after 4 ms
Internal Regulator
DRV
DEMAG ?
Rf
Demag
FB
Internal Clamp
V
err
Max = 3 V
V
err
Min = 10 mV
Clock
−
Ri
+
Flip−Flop
I
R
Q
sense
1/3
D
Driver
+
−
2.5 V
Current Comparator
Ct
GND
200 ns L.E.B
Over Current
Protection (OCP)
V(−) < 1.5 V
1 V
+
−
V
T
Feedback
CO
V
err
= f (V )
off
err
Max T = f (Ct)
off
Lasts more than 128 ms?
−−> Protection Circuitry
+
−
OVP
18 k
+
−
2.8 V
Figure 3. Internal Circuit Architecture for PDIP−8 Version
http://onsemi.com
4
NCP1205
V
CC
Pin 13
Startup
UVLO = 15 V
H
UVLO = 7.2 V
L
HV
NC
1
2
14
Internal V
CC
Last Pulse of Demag
Internal Regulator
after 4 ms
13 V
CC
3
12 DRV
DEMAG ?
Rf
Demag
Internal Clamp
V
err
Max = 3 V
V
err
Min = 10 mV
Clock
OVP
−
+
Ri
Flip−Flop
4
11 I
R
Q
FB
sense
1/3
D
Driver
+
−
2.5 V
Current Comparator
5
6
10
9
Ct
GND
NC
200 ns L.E.B
OVP
Over Current
Protection (OCP)
V(−) < 1.5 V
1 V
V
T
Feedback
CO
NC
NC
V
err
7
8
= f (V )
+
−
off
err
Max T = f (Ct)
off
+
−
Lasts more than 128 ms?
−−> Protection Circuitry
OVP
18 k
+
2.8 V
−
2.0 k
Figure 4. Internal Circuit Architecture for PDIP−14 Version
http://onsemi.com
5
NCP1205
MAXIMUM RATINGS
Pin No.
Value
PDIP−8 PDIP−14 SOIC−16
Min
Max
Rating
Symbol
Unit
V
Power Supply Voltage
8
13
14
V
in
−
30
Thermal Resistance Junction−to−Air
PDIP−8
PDIP−14
SOIC−16
−
−
−
−
−
−
−
−
−
R
−
−
100
100
145
°C/W
q
JA
Operating Junction Temperature Range
Maximum Junction Temperature
−
−
−
−
−
−
T
−
−
−25 to +125
°C
°C
J
T
150
Jmax
Storage Temperature Range
ESD Capability, HBM Model
ESD Capability, Machine Model
Demagnetization Pin Current
−
−
−
T
−
−
−
−
−60 to +150
2.0
°C
kV
V
stg
All Pins
All Pins
2
All Pins
All Pins
3
All Pins
All Pins
4
−
−
−
200
−5.0/+10
mA
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
ELECTRICAL CHARACTERISTICS (For typical values T = 25°C, for min/max values T = −25°C to +125°C, Max T = 150°C,
A
J
J
V
CC
= 12 V unless otherwise noted.)
Pin No.
PDIP−8 PDIP−14 SOIC−16
Characteristics
Symbol
Min
Typ
Max
Unit
Demagnetization Block
Input Threshold Voltage (V
increasing)
2
2
2
3
3
3
4
4
4
Vth
50
65
30
85
mV
mV
V
pin2
Hysteresis (V
decreasing)
V
H
−
−
pin2
Input Clamp Voltage
High State (I
Low State (I
= 3.0 mA)
= −3.0 mA)
VC
VC
8.0
−0.9
10
−0.7
12
−0.5
pin2
pin2
H
L
Demag Propagation Delay
No Demag Signal Activation
−
−
2
2
−
−
3
3
−
−
4
4
−
100
−
300
4.0
10
350
8.0
−
ns
ms
pF
ns
−
Internal Input Capacitance at 1.0 V
Demag Propagation Delay with 22 kW External Resistor
Feedback Path
C
−
pin2
−
100
370
480
Input Impedance at V = 3.0 V
3
3
−
−
−
4
4
−
−
−
5
5
−
−
−
Zin
AV
−
−
50
−3.0
2.5
−
−
kW
−
FB
Internal Error Amplifier Closed Loop Gain
Internal Built−In Offset Voltage for Error Detection
Error Amplifier Level of VCO Take Over
CL
V
ref
2.2
−
2.8
−
V
−
−
1.0
V
Internal Divider from Internal Error Amp, Pin to Current
Setpoint
−
3.0
−
−
Fault Detection Circuitry
Internal Over Current Level
−
−
−
−
6
−
−
−
−
−
−
−
−
−
7
WL
−
−
−
1.5
128
1.0
100
2.8
−
−
V
ms
s
L
Fault Time Duration to Latch Activation @ Ct = 1.0 ηF
Over Current Latchoff Phase @ Ct = 1.0 ηF
−
−
−
Hysteresis when V goes back into Regulation
−
−
−
mV
V
FB
Overvoltage Protection Threshold for PDIP−14 and
SOIC−16 versions
OVP1
2.5
3.1
Current Sense Comparator
Input Bias Current @ 1.0 V
6
6
6
11
11
11
12
12
12
I
−
0.02
1.0
−
mA
V
IB
Maximum Current Setpoint
Minimum Current Setpoint
V
0.9
225
1.1
285
cl
V
min
250
mV
http://onsemi.com
6
NCP1205
ELECTRICAL CHARACTERISTICS (continued) (For typical values T = 25°C, for min/max values T = 25°C to +125°C,
A
J
Max T = 150°C, V = 12 V unless otherwise noted.)
J
CC
Pin No.
PDIP−8 PDIP−14 SOIC−16
Characteristics
Symbol
Min
Typ
Max
Unit
Current Sense Comparator (continued)
Propagation Delay from Current Detection to Gate OFF
State
6
6
11
11
12
12
T
T
−
−
200
200
250
ns
ns
del
Leading Edge Blanking (LEB)
−
leb
Frequency Modulator
Minimum Frequency Operation @ Ct = 1.0 ηF and
4
4
5
5
6
6
F
−
0
−
kHz
kHz
min
V
CC
= 30 V
Maximum Frequency Operation @ Ct = 1.0 ηF and
= 30 V
F
max
90
110
125
V
CC
Minimum Ct Charging Current (Note 4)
Maximum Ct Charging Current (Note 4)
Discharge Time @ Ct = 1.0 ηF
4
4
4
5
5
5
6
6
6
I
min
−
280
−
0
−
420
−
mA
mA
ns
Ct
I
Ct
max
350
500
−
Drive Output
Output Voltage Rise Time @ C = 1.0 ηF (DV = 10 V)
7
7
12
12
12
12
13
13
13
12
t
−
−
30
30
13
−
50
50
16
0.5
ns
ns
V
L
r
Output Voltage Fall Time @ C = 1.0 ηF (DV = 10 V)
t
f
L
Clamped Output Voltage @ V = 30 V (Note 5)
7
V
V
11
−
CC
DRV
DRV
Voltage Drop on the Stage @ V = 10 V (Note 5)
12
V
CC
Undervoltage Lockout
Startup Threshold (V Increasing)
8
8
13
13
14
14
UVLO
13.5
6.5
15
16.5
8.0
V
V
CC
H
Minimum Operating Voltage (V Decreasing)
UVLO
7.2
CC
L
Startup Current Source
Maximum Voltage, Pin 1 Grounded
1
1
1
1
1
1
1
1
1
1
1
1
−
−
−
−
−
−
450
500
3.0
32
−
−
V
V
Maximum Voltage, Pin 1 Decoupled (470 mF)
Startup Current Source Flowing through Pin 1
Leakage Current in Offstate @ Vpin 1 = 500 V
2.3
−
4.8
70
mA
mA
Device Current Consumption
V
V
V
less than UVLO
8
8
8
8
13
13
13
13
14
14
14
14
−
−
−
−
−
−
1.5
1.2
3.0
−
1.8
3.0
4.0
−
mA
mA
mA
mA
CC
CC
CC
H
= 30 V and Fsw = 2.0 kHz, C = 1.0 ηF
L
= 30 V and Fsw = 125 kHz, C = 1.0 ηF
−
L
Startup Current to V Capacitor
1.4
CC
4. Typical capacitor swing is between 0.5 V and 3.5 V.
5. Guaranteed by design, T = 25°C.
J
http://onsemi.com
7
NCP1205
420
400
380
360
340
320
125
120
115
110
105
100
300
280
95
90
−50
0
50
100
150
−50
0
50
100
150
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 5. Ct Charging Current versus
Temperature
Figure 6. Switching Frequency @ Ct = 1 nF
versus Temperature
16.5
16
1100
1050
1000
15.5
15
14.5
950
900
14
13.5
−50
0
50
100
150
−50
0
50
100
150
TEMPERATURE (°C)
TEMPERATURE (°C)
Figure 7. Startup Threshold versus
Temperature
Figure 8. Maximum Current Setpoint versus
Temperature
8
7.75
7.5
7.25
7
6.75
6.5
−50
0
50
TEMPERATURE (°C)
100
150
Figure 9. Minimum Operating Voltage versus
Temperature
http://onsemi.com
8
NCP1205
APPLICATION INFORMATION
Introduction
nominal output power, the circuit implements a traditional
current−mode SMPS whose peak current setpoint is given
by the feedback signal. However, rather than keeping the
switching frequency constant, each cycle is initiated by the
end of the primary demagnetization. The system therefore
operates at the boundary between Discontinuous
Conduction Mode (DCM) and Continuous Conduction
Mode (CCM). Figure 10 details this terminology:
By implementing a unique smooth frequency reduction
technique, the NCP1205 represents a major leap toward
low−power Switchmode Power Supply (SMPS) integrated
management. The circuit combines free−running operation
with minimum drain−source switching (so−called valley
switching), which naturally reduces the peak current stress
as well as the ElectroMagnetic Interferences (EMI). At
L > Lc
I
L
Not 0 at
Turn ON
I
P
0
L = Lc
L < Lc
OFF
ON
I
L(avg)
0 Before
Turn ON
Borderline
D/Fs
0
Dead−Time
Time
Figure 10. Defining the Conduction Mode, Discontinuous, Continuous and Borderline
When the output power demands decreases, the natural
switching frequency raises. As a natural result, switching
losses also increase and degrade the SMPS efficiency. To
overcome this problem, the maximum switching frequency
of the NCP1205 is clamped to typically 125 kHz. When the
free running mode (also called Borderline Control Mode,
BCM) reaches this clamp value, an internal
Voltage−Controlled Oscillator (VCO) takes over and starts
to decrease the switching frequency: we are in Variable
Frequency Mode (VFM). Please note that during this
transition phase, the peak current is not fixed but is still
decreasing because the output power demand does. At a
given state, the peak current reaches a minimum peak
(typically 250 mV/Rsense), and cannot go further down: the
switching frequency continues its decrease down to a
possible minimum of 0 Hz (the IC simply stops switching).
During normal free−running operation and VFM, the
controller always ensures single or multiple drain−source
valley switching. We will see later on how this is internally
implemented.
The FLYBACK operation is mainly defined through a
simple formula:
1
2
2
Pout + · Lp · Ip · Fsw
(eq. 1)
With:
Lp the primary transformer inductance (also called the
magnetizing inductance)
Ip the peak current at which the MOSFET is turned off
Fsw the nominal switching frequency
To adjust the transmitted power, the PWM controller can
play on the switching frequency or the peak current setpoint.
To refine the control, the NCP1205 offers the ability to play
on both parameters either altogether on an individual basis.
http://onsemi.com
9
NCP1205
In order to clarify the device behavior, we can distinguish the
Detailed Description
following simplified operating phases:
The following sections describe the internal behavior of
the NCP1205.
1. The load is at its nominal value. The SMPS operates in
borderline conduction mode and the switching
frequency is imposed by the external elements (Vin,
Lp, Ip, Vout). The MOSFET is turned on at the
minimum drain−source level.
Free−Running Operation
As previously said, the operating frequency at nominal load
is dictated by the external elements. We can split the different
switching sections in two separated instants. In the following
text we use the internal error voltage, Verr. This level is
elaborated in Figure 13. Verr is linked to VFB (pin 4) by the
following formula:
2. The load starts to decrease and the free−running
frequency hits the internal clamp.
3. The frequency can no longer naturally increase
because of the clamp. The frequency is now controlled
by the internal VCO but remains constant. The peak
current finds no other option that diminishing to satisfy
equation (1).
4. The peak current has reached the internal minimum
ceiling level and is now frozen for the remaining
cycles.
Verr + 10 * 3 · V
(eq. 2)
FB
ON time: The ON time is given by the time it takes to
reach the peak current setpoint imposed by the level on FB
pin (pin 4). Since this level is internally divided by three, the
peak setpoint is simply:
1
Ipk +
· Verr
(eq. 3)
5. To further reduce the transmitted power (V goes up),
FB
3 · Rsense
the VCO decreases the switching frequency. In case of
output overshoot, the VCO could decrease the
frequency down to zero. When the overshoot has gone,
The rising slope of the peak current is also dependent on
the inductance value and the rectified DC input voltage by:
dIL
dt
Vin
DC
Lp
V
FB
diminishes again and the IC smoothly resumes its
+
(eq. 4)
operation.
By combining both equations, we obtain the ON time
definition:
Lp
Vin
Lp · V
ERR
· 3 · Rsense
ton +
· Ip +
(eq. 5)
Advantages of the Method
By implementing the aforementioned control scheme, the
NCP1205 brings the following advantages:
• Discontinuous only operation: in DCM, the Flyback is
a first order system (at low frequencies) and thus
naturally eases the feedback loop compensation.
• A low−cost secondary rectifier can be used due to
smooth turn−off conditions.
Vin
DC
DC
OFF time: The time taken by the demagnetization of the
transformer depends on the reset voltage applied at the
switch opening. During the conduction time of the
secondary diode, the primary side of the transformer
undergoes a reflected voltage of: [Np/Ns . (Vf + Vout)]. This
voltage applied on the primary inductance dictates the time
needed to decrease from Ip down to zero:
• Valley switching ensures minimum switching losses
brought by Coss and all the parasitic capacitances.
• By folding back the switching frequency, you turn the
system into Pulse Duration Modulation. This method
prevents from generating uncontrolled output ripple as
with hysteretic controllers.
Lp
toff +
Np
Ns
ƪ
· (Vout ) Vf)ƫ
(eq. 6)
Lp · Verr
· Ip +
Np
Ns
ƪ
· (Vout ) Vf)ƫ · 3 · Rsense
By adding ton + toff, we obtain the natural switching
frequency of the SMPS operating in Borderline Conduction
Mode (BCM):
• By letting you control the peak current value at which
the frequency goes down, you ensure that this level is
low enough to avoid transformer acoustic noise
generation even at audible frequencies.
ȱ
ȳ
Verr · Lp
3 · Rsense
1
DC
1
)
ton ) toff +
·
ȧVin
ȧ
· (Vout ) Vf)ƫ
Np
Ns
ƪ
Ȳ
ȴ
(eq. 7)
http://onsemi.com
10
NCP1205
If we now enter this formula into a spreadsheet, we can easily plot the switching frequency versus the output power demand:
250000
Transition
BCM to VFM
200000
150000
100000
Fmax
Fmax
50000
0
V
CO
Action
5
0
10
15
20
OUTPUT POWER (W)
Figure 11. A Typical Behavior of Free Running Systems
with a Smooth Frequency Foldback with the NCP1205
The typical above diagram shows how the frequency
the VCO frequency decreases with a typical small−signal
slope of −175 kHz/mV @ Verr = 500 mV down to
zero (typically at FB ≈ 3.3 V). The demagnetization
synchronization is however kept when the Toff expands.
The maximum switching frequency can be altered by
adjusting the Ct capacitor on pin 5. The 125 kHz maximum
operation ensures that the fundamental component stays
external from the international EMI CISPR−22
specification beginning.
moves with the output power demand. The components used
for the simulation were: Vin = 300 V, Lp = 6.5 mH,
Vout = 10 V, Np/Ns = 12.
The red line indicates where the maximum frequency is
clamped. At this time, the VCO takes over and decreases the
switching frequency to the minimum value.
VCO Operation
The VCO is controlled from the Verr voltage. For Verr
levels above 1.0 V, the VCO frequency remains unchanged
at 125 kHz. As soon as Verr starts to decrease below 1.0 V,
The following drawing explains the philosophy behind
the idea:
Internal V
err
3 V
V
Frequency
CO
BCM Mode
Peak current
can change
is Fixed at 130 kHz
1 V
0.75 V
V
CO
Frequency
can Decrease
Peak Current is Fixed
Figure 12. When the Power Demand goes Low, the Peak Current is Frozen and the Frequency Decreases
http://onsemi.com
11
NCP1205
Zero Crossing Detector
given point, the demag activity on the auxiliary
winding becomes too low to be detected. To avoid
any restart problem, the NCP1205 features an
internal 4.0 ms timeout delay. This timeout runs
after each demag pulse. If within 4.0 ms further to
a demag pulse no activity is detected, an internal
signal is combined with the VCO to actually
restart the MOSFET (synchronized with Ct).
To detect the zero primary current, we make use of an
auxiliary winding. By coupling this winding to the primary,
we have a voltage image of the flux activity in the core.
Figure 10 details the shape of the signal in BCM (L = Lc).
The auxiliary winding for demagnetization needs to
be wired in Forward mode. However, the application
note describes an alternative solution showing how to wire
the winding in Flyback as well. As Figure 13 depicts, when
the MOSFET closes, the auxiliary winding delivers
(Naux/Np . Vin). At the switch opening, we couple the
auxiliary winding to the main output power winding and
thus deliver: (−Naux/Ns . Vout). When DCM occurs, the
ringing also takes place on the auxiliary winding. As soon
as the level crosses−up the internal reference level
(65 mV), a signal is internally sent to restart the MOSFET.
Three different conditions can occur:
Error Amplifier and Fault Detection
The NCP1205 features an internal error amplifier solely
used to detect an overcurrent problem. The application
assumes that all the error gain associated with the precise
reference level is located on the secondary side of the SMPS.
Various solutions can be purposely implemented such as the
TL431 or a dedicated circuit like the MC33341. In the
NCP1205, the internal OPAMP is used to create a virtual
ground permanently biased at 2.5 V (Figure 14), an internal
reference level. By monitoring this virtual ground further
called V(−), we have the possibility to confirm the good
behavior of the loop. If by any mean the loop is broken
(shorted optocoupler, open LED etc.) or the regulation
cannot be reached (true output short−circuit), the OPAMP
network is adjusted in order to no longer be able to ensure
the 2.5 V virtual point V(−). If V(−) passes down the 1.5 V
level (e.g. output shorted) for a time longer than 128 ms, then
the pulses are stopped for 8 x 128 ms. The IC enters a kind
of burst mode with bunch of pulses lasting 128 ms and
repeating every 8 x 128 ms. If the loop is restored within the
8 x 128 ms period, then the pulses are back again on the
1. In BCM, every time the 65 mV line is crossed, the
switch is immediately turned−on. By accounting
for the internal Demag pin capacitance (10−15 pF
typical), you can introduce a fixed delay, which,
combined to the propagation delay, allows to
precisely restart in the drain−source valley
(minimum voltage to reduce capacitive losses).
2. When the IC enters VFM, the VCO delivers a
pulse which is internally latched. As soon as the
demagnetization pulse appears, the logic restarts
the MOSFET.
3. As can be seen from Figure 13, the parasitic
oscillations on the drain are subject to a natural
damping, mainly imputed to ohmic losses. At a
output drive (synchronized with UVLO ).
H
Drain Level
Valley
Switching
Possible Demag
65 mV
0 V
2
Auxiliary Level
4 ms
I
P
= 0
Restart when Demag is too low
750.0 U 754.0 U 758.0 U
762.0 U
766.0 U
Figure 13. Core Reset Detection is done through an Auxiliary Winding Operated in Forward
http://onsemi.com
12
NCP1205
Monitor
Rf
150 k
V
fb
V
V
= 3 V
= 5 mV
HIGH
LOW
Ri
50 k
V(−)
2R
−
+
Current
Setpoint
3
1
6
2
+
V
fb
+
V1
2.5 V
R
+
−
OCP
Circuitry
7
5
+
V
low
1.5 V
Figure 14. This Typical Arrangement Allows for an Easy Fault Detection Management
To illustrate how the system reacts to a variable FB level,
we have entered the above circuit into a SPICE simulator
and observed the output waveforms. When FB is within
regulation, the error flag is low. However, as soon as FB
leaves its normal operating area, the OPAMP can no longer
keep the V(−) point and either goes to the positive top or
down to zero: the error flag goes high.
connected from ground to pin 5. In normal VFM operation,
this timing capacitor serves as the VCO capacitor and the
error management circuit is transparent. As soon as an error
is detected (error flag goes high), an internal switch routes
Ct to the 128 ms generator. As a first effect, the switching
frequency is no longer controlled by the VCO (if the error
appears during VFM) and the system is relaxed to natural
BCM. The capacitor now ramps up and down to be further
divided and finally create the 128 ms delay.
Because of the large amount of delay necessary for this
128 ms operation, the capacitor used for the timing is Ct,
6.500
FB
Regulation Area
4.500
2.500
Virtual Point
1.5 V
OCP Condition
500.0 M
Error Flag
1.000 M
3.000 M
5.000 M
7.000 M
9.000 M
Figure 15. By Monitoring the Internal Virtual Ground, the System can Detect the Presence of a Fault
http://onsemi.com
13
NCP1205
As soon as the system recovers from the error, e.g. FB is
Overvoltage Detection (OVP)
back within its regulation area, the IC operation comes back
to normal.
On the PDIP−14 and the SOIC−16 versions, an OVP pin
allows to shutdown the controller as soon as the level on this
pin exceeds 2.8V, as detailed in Figure 16. In lack of
switching pulses, the Vcc capacitor is no longer refreshed by
the auxiliary supply and slowly discharges toward ground.
When the Vcc level crosses UVLOL, a new startup sequence
occurs. If the OVP has gone, the converter resumes its
operation.
To avoid any system thermal runaway, another internal
8 x 128 ms delay is combined with the previous 128 ms. It
works as follows: the 128 ms delay is provided to account for
any normal transients that engender a temporary loss of
feedback (FB goes toward ground). However, when the
128 ms period is actually over (the feedback is definitively
lost) the IC stops the output driving pulses for a typical
period of 8 x 128 ms. During this mode, the rest of the
functions are still activated. For instance, in lack of pulses,
the self−supplied being no longer provided, the startup
source turns on and off (when reaching the corresponding
+
−
OVP
Latched
OVP
7
1
8
2 k
2
18 k
+
2.8 V
UVLO and UVLO levels), creating an hiccup waveform
L
H
on the Vcc line. As soon as the feedback condition is
restored, the 8 x 128 ms is interrupted and, in synchronism
with the Vcc line, the IC is back to normal. The following
diagrams show how this mechanism takes place when FB is
down to zero (optocoupler opened) or up to Vcc
(optocoupler shorted). If we assume that the error is
permanently present, then a burst mode takes place with a
128/8 x 128 = 12.5% duty−cycle. The real transmitted
power is thus:
Figure 16. In the PDIP−8 Version, the OVP Pad is not
Pinned Out and is Available with PDIP−14 Devices
Only
Protecting Pin 1 Against Negative Spikes
As any CMOS controller, NCP1205 is sensitive to
negative voltages that could appear on it’s pins. To avoid any
adverse latch−up of the IC, we strongly recommend
inserting a 15 k resistor in series with pin 1 and the
high−voltage rail, as shown in Figures 17 and 18. This 15 k
resistor prevents from adversely latching the controller in
case of negative spikes appearing on the bulk capacitor
during the power−off sequence. Please note that this resistor
does not dissipate any continuous power and can therefore
be of low power type. Two 8.2 k can also be wired in series
to sustain the large DC voltage present on the bulk.
1
2
2
· Lp · Ip · Fsw · Duty
BURST
Pout
+
BURST
http://onsemi.com
14
NCP1205
OVP detected on Pin 6
V
CC
UVLO
UVLO
H
L
Drive
Unit V Reaches UVLO
CC
L
Figure 17. When the VCC Voltage Goes Above the
Maximum Value, the Device Enters Safe Burst Mode
V
CC
Arbitrary V Representation
CC
UVLO
UVLO
H
L
Drive
8 x 128 ms maximum if loop does not
recover
V(−)
3.5 V
1.5 V
Loop Recovers
Here
128 ms
Figure 18. When the Internal V(−) Passes Below 1.5 V, the IC
Senses a Short−Circuit Event
http://onsemi.com
15
NCP1205
PACKAGE DIMENSIONS
PDIP−8
N SUFFIX
CASE 626−05
ISSUE L
NOTES:
1. DIMENSION L TO CENTER OF LEAD WHEN
FORMED PARALLEL.
8
5
2. PACKAGE CONTOUR OPTIONAL (ROUND OR
SQUARE CORNERS).
3. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
−B−
1
4
MILLIMETERS
INCHES
MIN
DIM MIN
MAX
10.16
6.60
4.45
0.51
1.78
MAX
0.400
0.260
0.175
0.020
0.070
A
B
C
D
F
9.40
6.10
3.94
0.38
1.02
0.370
0.240
0.155
0.015
0.040
F
−A−
NOTE 2
L
G
H
J
2.54 BSC
0.100 BSC
0.76
0.20
2.92
1.27
0.30
3.43
0.030
0.008
0.115
0.050
0.012
0.135
K
L
C
7.62 BSC
0.300 BSC
M
N
−−−
0.76
10
_
1.01
−−−
0.030
10
_
0.040
J
−T−
SEATING
PLANE
N
M
D
K
G
H
M
M
M
0.13 (0.005)
T A
B
PDIP−14
CASE 646−06
ISSUE P
NOTES:
1. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
2. CONTROLLING DIMENSION: INCH.
3. DIMENSION L TO CENTER OF LEADS WHEN
FORMED PARALLEL.
4. DIMENSION B DOES NOT INCLUDE MOLD FLASH.
5. ROUNDED CORNERS OPTIONAL.
14
1
8
7
B
INCHES
MILLIMETERS
A
F
DIM
A
B
C
D
F
MIN
MAX
0.770
0.260
0.185
0.021
0.070
MIN
18.16
6.10
3.69
0.38
1.02
MAX
19.56
6.60
4.69
0.53
1.78
0.715
0.240
0.145
0.015
0.040
L
N
C
G
H
J
K
L
M
N
0.100 BSC
2.54 BSC
0.052
0.008
0.115
0.290
−−−
0.095
0.015
0.135
0.310
10
1.32
0.20
2.92
7.37
−−−
0.38
2.41
0.38
3.43
7.87
10
−T−
SEATING
PLANE
J
_
_
K
0.015
0.039
1.01
D 14 PL
H
G
M
M
0.13 (0.005)
http://onsemi.com
16
NCP1205
PACKAGE DIMENSIONS
SOIC−16
D SUFFIX
CASE 751B−05
ISSUE J
NOTES:
1. DIMENSIONING AND TOLERANCING PER ANSI
Y14.5M, 1982.
−A−
2. CONTROLLING DIMENSION: MILLIMETER.
3. DIMENSIONS A AND B DO NOT INCLUDE
MOLD PROTRUSION.
4. MAXIMUM MOLD PROTRUSION 0.15 (0.006)
PER SIDE.
5. DIMENSION D DOES NOT INCLUDE DAMBAR
PROTRUSION. ALLOWABLE DAMBAR
PROTRUSION SHALL BE 0.127 (0.005) TOTAL
IN EXCESS OF THE D DIMENSION AT
MAXIMUM MATERIAL CONDITION.
16
9
8
−B−
P 8 PL
M
S
B
0.25 (0.010)
1
MILLIMETERS
INCHES
MIN
0.386
G
DIM MIN
MAX
MAX
0.393
0.157
0.068
0.019
0.049
A
B
C
D
F
9.80
3.80
1.35
0.35
0.40
10.00
4.00 0.150
1.75 0.054
0.49 0.014
1.25 0.016
F
R X 45
K
_
G
J
1.27 BSC
0.050 BSC
C
0.19
0.10
0
0.25 0.008
0.25 0.004
0.009
0.009
7
−T−
SEATING
PLANE
K
M
P
R
J
7
0
_
_
_
_
M
5.80
0.25
6.20 0.229
0.50 0.010
0.244
0.019
D
16 PL
M
S
S
0.25 (0.010)
T B
A
ON Semiconductor and
are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice
to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages.
“Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All
operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights
nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications
intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should
Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates,
and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death
associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal
Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT:
N. American Technical Support: 800−282−9855 Toll Free
USA/Canada
Europe, Middle East and Africa Technical Support:
Phone: 421 33 790 2910
Japan Customer Focus Center
Phone: 81−3−5773−3850
ON Semiconductor Website: www.onsemi.com
Order Literature: http://www.onsemi.com/orderlit
Literature Distribution Center for ON Semiconductor
P.O. Box 5163, Denver, Colorado 80217 USA
Phone: 303−675−2175 or 800−344−3860 Toll Free USA/Canada
Fax: 303−675−2176 or 800−344−3867 Toll Free USA/Canada
Email: orderlit@onsemi.com
For additional information, please contact your local
Sales Representative
NCP1205/D
相关型号:
NCP1207ADR2G
0.5 A SWITCHING CONTROLLER, 200 kHz SWITCHING FREQ-MAX, PDSO8, HALOGEN AND LEAD FREE, SOIC-8
ROCHESTER
NCP1207APG
0.5A SWITCHING CONTROLLER, 200kHz SWITCHING FREQ-MAX, PDIP8, HALOGEN AND LEAD FREE, PLASTIC, DIP-8
ROCHESTER