TXD3XGGI2C00041G [OPLINK]

Transceiver with Digital Diagnostics;
TXD3XGGI2C00041G
型号: TXD3XGGI2C00041G
厂家: OPLINK COMMUNICATIONS INC.    OPLINK COMMUNICATIONS INC.
描述:

Transceiver with Digital Diagnostics

文件: 总9页 (文件大小:921K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Multi-rate 10-Gigabit DWDM 40km XFP  
Transceiver with Digital Diagnostics  
TXD3XGGI2xx  
Pb  
Product Description  
TheTXD3XGGI2xx DWDM XFP multi-rate fiber optic transceivers with digital  
diagnostics monitoring functionality provide a quick and reliable interface  
for 40km 10Gbps DWDM applications. The diagnostic functions, alarm and  
warning features as described in the XFP Multi-Source Agreement (MSA)  
are provided via standard I2C serial interface. The transceivers are compliant  
with the XFP Multi-Source Agreement and are designed to support SONET/  
SDH, 10G Ethernet, and 10G Fiber Channel data rates from 9.95Gb/s to  
11.09Gb/s.  
Each transceiver utilizes an electro-absorption modulator integrated laser  
with an operating wavelength in full compliance with 100GHz (0.8nm)  
spacing per the ITU-grid. The transceivers satisfy Class I Laser Safety  
requirements in accordance with the U.S. FDA/CDRH and international IEC-  
60825 standards.  
Features  
The transceivers connect to standard 30-pad XFP connectors for hot plug  
capability. This allows the system designer to make configuration changes  
or maintenance by simply plugging in different types of transceivers  
without removing the power supply from the host system.  
Lead Free Design & Fully RoHS Compliant  
Compliant with XFP MSA  
Compliant with OC-192/STM-64  
Compliant with ITU-T G.709  
The transmitter and receiver DATA interfaces are AC coupled Current Mode  
Logic (CML). LV-TTL Transmitter Disable control input and Loss of Signal  
output interfaces are also provided.  
Support DWDM 10G Ethernet Applications  
Support 10G Fiber Channel Applications  
Digital Diagnostics Monitoring  
Temperature-stabilized EML Transmitter  
Low Power Consumption  
The transceivers operate from +3.3V and +5.0V power supplies over a  
operating case temperature range of -5°C to +70°C (Commercial), -5°C to  
+85°C (Extended), or -40°C to +85°C (Industrial).  
Wide Case Operating Temperature Range  
Transmission Distance up to 40km  
Absolute Maximum Ratings  
Parameter  
Symbol  
Minimum  
Maximum  
Units  
TST  
Storage Temperature  
- 40  
+ 85  
°C  
Commercial  
Extended  
Industrial  
- 5  
- 5  
+ 70  
+ 85  
+ 85  
+ 3.6  
+ 6.0  
85  
Operating Case Temperature 1  
TOP  
°C  
- 40  
- 0.2  
- 0.2  
0
VCC  
VCC  
3
5
Supply Voltage  
V
Operating Relative Humidity 2  
%
V
RH  
VIN  
V CC  
Input Voltage  
1
0
Case temperature is measured on top side of XFP module.  
Non condensing  
2
S0330. Rev.04. (web) 2013-01-09  
TXD3XGGI2xx  
(Over Operating Case Temperature Range)  
Transmitter Performance Characteristics  
Parameter  
Operating Data Rate  
Symbol  
Minimum  
Typical  
Maximum  
Units  
B
PO  
9.95  
- 1.0  
-
-
-
-
-
11.09  
+ 3.0  
- 45.0  
-
Gb/s  
dBm  
dBm  
dB  
Average Optical Output Power (50% duty cycle)  
Transmitter OFF Power  
POFF  
ER  
Extinction Ratio @ 9.95Gb/s to 10.7Gb/s  
Center Wavelength 1  
8.2  
λC  
See Ordering Information Table  
nm  
Spectral Width (-20dB) 2  
Δλ20  
SMSR  
RIN  
refT  
-
30  
-
-
-
-
-
-
-
-
-
1.0  
-
nm  
Side Mode Suppression Ratio  
Relative Intensity Noise  
dB  
- 130  
- 27  
0.3  
0.1  
2.0  
2.5  
dB/Hz  
dB  
Reflectance Tolerance  
-
20 kHz – 80 MHz  
JG20K  
JG4M  
-
UIpp  
UIpp  
3
Jitter Generation  
4 MHz – 80 MHz  
@ 9.95Gb/s (10-12 BER)  
@ 11.09Gb/s (10-4 BER)  
-
-
4
Dispersion Penalty  
DP  
dB  
-
Optical Output Eye  
Compliant with GR253-CORE, IEEE 803.3ae , and ITU-T G.959  
1 BOL: +/-0.05nm from ITU grid. EOL: +/-0.1nm from ITU grid.  
2 Measured with OSA and 0.1nm resolution bandwidth.  
3 Jiꢀer generation is compliant with GR-253 and G.8251.  
(Over Operating Case Temperature Range)  
Receiver Performance Characteristics  
Parameter  
Operating Data Rate  
Symbol  
Minimum  
Typical  
Maximum  
Units  
9.95  
-
11.09  
B
Gb/s  
nm  
Wavelength of Operation  
λ
1260  
-
-
-
-
-
-
-
-
1570  
- 16.0  
- 19.0  
-
@ 9.95Gb/s (10-12 BER)  
Receiver Sensitivity  
-
Pmin  
dBm  
dBm  
dBm  
@ 11.09Gb/s (10-4 BER)  
-
+ 0.5  
-
Maximum Input Power  
PMAX  
Plos+  
Plos-  
-
Increasing Light Input  
LOS Thresholds  
- 16.0  
-
Decreasing Light Input  
- 28.0  
0.5  
-
LOS Hysteresis  
-
dB  
dB  
Receiver Reflectance  
-
- 27  
Laser Safety: All transceivers are Class I Laser  
Oplink Communications, Inc.  
products per FDA/CDRH and IEC-60825 standards.  
They must be operated under specified operating  
conditions.  
This product complies with  
21 CFR 1040.10 and 1040.11  
Meets Class I Laser Safety Requirements  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
2
TXD3XGGI2xx  
Electrical Interface (Over Operating Case Temperature Range)  
Parameter  
Differential Impedance  
Symbol  
Minimum  
Typical  
Maximum  
Units  
Zd  
-
100  
-
Ω
Vpp, diff_in  
Vpp, diff_out  
Differential Input Voltage Swing  
Differential Output Voltage Swing  
Output Rise/Fall Time (20 to 80%)  
120  
-
820  
mV  
mV  
ps  
340  
550  
850  
T /Tf  
24  
-
-
-
-
-
-
0.8  
r
VIL  
VIH  
VOL  
VOH  
- 0.3  
TX_Dis, P_Down/RST  
V
V
2.0  
VCC + 0.3  
0.4  
0
XFP Interrupt, Mod_NR, RX_LOS  
host_VCC - 0.5  
host_VCC + 0.3  
(Over Operating Case Temperature Range)  
Electrical Power Supply Characteristics  
Parameter  
Power Supply Voltage  
Symbol  
Minimum  
Typical  
Maximum  
Units  
VCC3  
VCC5  
ICC3  
3.13  
3.3  
3.47  
5.25  
750  
500  
3.5  
V
4.75  
5.0  
-
-
-
-
-
-
-
-
Supply Current  
mA  
ICC5  
Power Dissipation  
PW  
W
W
PDW  
1.5  
P_Down Power Dissipation  
XFP Transceiver Electrical Pad Layout  
Host Board Connector Pad Layout  
GND  
30 GND  
29 TD+  
28 TD-  
1
GND  
TD+  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
1
GND  
V
5
2
EE  
2
V
5
EE  
Mod_DeSel  
Interrupt  
TX_Dis  
3
TD-  
3
Mod_DeSel  
Interrupt  
TX_Dis  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
GND  
4
GND  
4
GND  
5
GND  
5
V
5
RefCLK-  
RefCLK+  
GND  
6
CC  
RefCLK-  
RefCLK+  
6
V
5
cc  
GND  
7
7
GND  
V
3
8
CC  
GND  
Toward  
Bezel  
Toward  
ASIC  
8
V
V
3
3
cc  
V
3
V
2
9
CC  
CC  
V
2
cc  
9
cc  
SCL  
TP_Down/RS  
10  
11  
12  
13  
14  
15  
P_Down/RST  
10  
11  
12  
13  
14  
15  
SCL  
SDA  
V
2
CC  
V
2
cc  
SDA  
Mod_Abs  
Mod_NR  
RX_LOS  
GND  
GND  
RD+  
RD-  
GND  
RD+  
RD-  
Mod_Abs  
Mod_NR  
RX_LOS  
GND  
GND  
GND  
Bottom of XFP Board  
(as viewed thru top of board)  
Top of XFP Board  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
3
TXD3XGGI2xx  
Module Pin Description  
Pin  
Logic  
Symbol  
Description  
1
Module Ground  
-
GND  
VEE5  
2
3
4
-
Optional -5.2V Power Supply (Not Required)  
LVTTL-I  
Mod_DeSel  
Module De-select; When held low allows module to respond to 2-wire serial interface  
Interrupt; Indicates presence of an important condition which can be read over the 2-wire serial  
Interface  
LVTTL-O  
Interrupt  
5
LVTTL-I  
TX_Dis  
VCC5  
Transmitter Disable; Turns off transmitter laser output  
+5V Power Supply  
6
-
7
-
GND  
VCC3  
Module Ground  
8
-
+3.3V Power Supply  
9
-
LVTTL-I/O  
LVTTL-I/O  
LVTTL-O  
LVTTL-O  
LVTTL-O  
-
VCC3  
+3.3V Power Supply  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
SCL  
2-Wire Serial Interface Clock  
2-Wire Serial Interface Data Line  
Indicates Module is not present. Grounded in the Module  
Module Not Ready; Indicating Module Operational Fault  
Receiver Loss Of Signal Indicator  
Module Ground  
SDA  
Mod_Abs  
Mod_NR  
RX_LOS  
GND  
GND  
RD-  
-
Module Ground  
CML-O  
CML-O  
-
Receiver Inverted Data Output  
Receiver Non-Inverted Data Output  
Module Ground  
RD+  
GND  
VCC2  
-
Nor Used  
Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire  
serial interface must be functional in the low power mode.  
21  
LVTTL-I  
P_Down/RST  
Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface,  
equivalent to a power cycle.  
22  
23  
24  
25  
26  
27  
28  
29  
30  
-
VCC2  
GND  
Not Used  
-
PECL-I  
PECL-I  
-
Module Ground  
RefCLK+  
RefCLK-  
GND  
Reference Clock Non-Inverted Input (Not Required)  
Reference Clock Inverted Input (Not Required)  
Module Ground  
-
GND  
Module Ground  
CML-I  
CML-I  
-
TD-  
Transmitter Inverted Data Input  
Transmitter Non-Inverted Data Input  
Module Ground  
TD+  
GND  
S0330. Rev.04. (web) 2013-01-09  
4
Oplink Communications, Inc  
TXD3XGGI2xx  
Host Board Termination & Coupling  
50Ω line  
TD+  
CML  
INPUTS  
50Ω line  
50Ω line  
TD-  
RD+  
CML  
OUTPUTS  
1µH coil or  
ferrite inductor  
50Ω line  
RD-  
8, 9  
+3.3V  
+5.0V  
+
0.1  
10  
0.1  
0.1  
ASIC/  
SerDes  
XFP  
1µH coil or  
+3.3V  
ferrite inductor  
+3.3V  
6
+
0.1  
10  
R
+3.3V  
R
SCL, SDA,  
R
Mod_Abs, Mod_NR,  
Interrupt, RX_LOS  
R: 4.7 to 10kΩ  
All caps are in units of µF  
Application Notes  
Electrical Interface: All signal interfaces are compliant with  
the XFP MSA specification. The high speed DATA interface is  
differential AC-coupled internally and can be directly connected  
to a 3.3V SERDES IC.  
be added to the Mod_NR. The Mod_NR output pin is an open  
collector and must be pulled to Host_Vcc on the host board.  
P_Down/RST: The negative edge of Reset Function signal  
initiates a complete module reset.  
RX_LOS: The Loss of Signal circuit monitors the level of the  
incoming optical signal and generates a logic HIGH when an  
insufficient photocurrent is produced.  
Module Behavior During P_Down and RST: During execution  
of a reset (t_init) or while held in Power Down mode, a module  
may be unable to determine the correct value for Mod_NR and  
RX_LOS. These outputs as well as all interrupt related flags,  
except completion of Reset flag, shall be disregarded by the  
host. When the module completes a Reset and is not in Power  
Down mode, the module must represent the correct value of  
both signals on its outputs before posting a completion of reset  
interrupt to the host.  
TX_Dis: When theTX Disable pin is at logic HIGH, the transmitter  
optical output is disabled. (less than -45dBm).  
P_Down: The Power Down Function pin, when held High by  
the host, places the module in the standby (Low Power) mode  
with a maximum power dissipation of 1.5W. This protects hosts  
which are not capable of cooling higher power modules which  
may be accidentally inserted.The module’s 2-wire serial interface  
and all laser safety functions must be fully functional in this low  
power mode. During P_Down, the module shall still support the  
completion of reset Interrupt, as well as maintain functionality  
of the variable power supply.  
At no time shall a module cause spurious assertion of the  
Interrupt pin. When a host initially applies power to a module  
with the P_Down/RST signal asserted, a module comes up in  
power down mode. The module shall only assert the Interrupt  
signal pin to inform the host it has completed a reset. The  
completion of reset flag shall be the only interrupt source flag  
set during power down mode. The host is expected to clear this  
interrupt before releasing the module from the power down  
mode. The transition from power down mode to normal mode  
will trigger a reset of the module and result in a 2nd module reset  
and a 2nd reset completion interrupt to the host.  
Mod_NR:The Mod_NR is an output pin that when High, indicates  
that the module has detected a condition that renders transmitter  
and or receiver data invalid, shall consist of logical OR of the  
following signals:  
• Transmit Signal Conditioner Loss of Lock  
• Transmitter Laser Fault  
Power Supply and Grounding: The power supply line should  
be well-filtered. All 0.1μF power supply bypass capacitors should  
be as close to the transceiver module as possible.  
• Receiver Signal Conditioner Loss of Lock  
Other conditions deemed valuable to the detection of fault may  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
5
TXD3XGGI2xx  
Package Outline  
DIMENSION IN MILLIMETERS  
NOTES: UNLESS OTHERWISE  
SPECIFIED  
Ordering Information  
Oplink can provide a remarkable range of customized optical solutions. For detail, please contact Oplink’s Sales and Mar-  
keting for your requirements and ordering information (510) 933-7200 or Sales@oplink.com.  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Color  
Model Name  
Operating Temperature  
Distance  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
TXD3XGGI2C00061G  
TXD3XGGI2C00060G  
TXD3XGGI2C00059G  
TXD3XGGI2C00058G  
TXD3XGGI2C00057G  
TXD3XGGI2C00056G  
TXD3XGGI2C00055G  
TXD3XGGI2C00054G  
TXD3XGGI2C00053G  
TXD3XGGI2C00052G  
TXD3XGGI2C00051G  
TXD3XGGI2C00050G  
TXD3XGGI2C00049G  
TXD3XGGI2C00048G  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
1528.77  
1529.55  
1530.33  
1531.12  
1531.90  
1532.68  
1533.47  
1534.25  
1535.04  
1535.82  
1536.61  
1537.40  
1538.19  
1538.98  
196.1  
196  
61  
60  
59  
58  
57  
56  
55  
54  
53  
52  
51  
50  
49  
48  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
195.9  
195.8  
195.7  
195.6  
195.5  
195.4  
195.3  
195.2  
195.1  
195.0  
194.9  
194.8  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
6
TXD3XGGI2xx  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Model Name  
Operating Temperature  
Distance  
Color  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
Commercial  
TXD3XGGI2C00047G  
TXD3XGGI2C00046G  
TXD3XGGI2C00045G  
TXD3XGGI2C00044G  
TXD3XGGI2C00043G  
TXD3XGGI2C00042G  
TXD3XGGI2C00041G  
TXD3XGGI2C00040G  
TXD3XGGI2C00039G  
TXD3XGGI2C00038G  
TXD3XGGI2C00037G  
TXD3XGGI2C00036G  
TXD3XGGI2C00035G  
TXD3XGGI2C00034G  
TXD3XGGI2C00033G  
TXD3XGGI2C00032G  
TXD3XGGI2C00031G  
TXD3XGGI2C00030G  
TXD3XGGI2C00029G  
TXD3XGGI2C00028G  
TXD3XGGI2C00027G  
TXD3XGGI2C00026G  
TXD3XGGI2C00025G  
TXD3XGGI2C00024G  
TXD3XGGI2C00023G  
TXD3XGGI2C00022G  
TXD3XGGI2C00021G  
TXD3XGGI2C00020G  
TXD3XGGI2C00019G  
TXD3XGGI2C00018G  
TXD3XGGI2C00017G  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
- 5°C to +70°C  
1539.77  
1540.56  
1541.35  
1542.14  
1542.94  
1543.73  
1544.53  
1545.32  
1546.12  
1546.92  
1547.72  
1548.51  
1549.32  
1550.12  
1550.92  
1551.72  
1552.52  
1553.33  
1554.13  
1554.94  
1555.75  
1556.55  
1557.36  
1558.17  
1558.98  
1559.79  
1560.61  
1561.42  
1562.23  
1563.05  
1563.86  
194.7  
194.6  
194.5  
194.4  
194.3  
194.2  
194.1  
194.0  
193.9  
193.8  
193.7  
193.6  
193.5  
193.4  
193.3  
193.2  
193.1  
193.0  
192.9  
192.8  
192.7  
192.6  
192.5  
192.4  
192.3  
192.2  
192.1  
192.0  
191.9  
191.8  
191.7  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Color  
Model Name  
Operating Temperature  
Distance  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
TXD3XGGI2E00061G  
TXD3XGGI2E00060G  
TXD3XGGI2E00059G  
TXD3XGGI2E00058G  
TXD3XGGI2E00057G  
TXD3XGGI2E00056G  
TXD3XGGI2E00055G  
TXD3XGGI2E00054G  
TXD3XGGI2E00053G  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
1528.77  
1529.55  
1530.33  
1531.12  
1531.90  
1532.68  
1533.47  
1534.25  
1535.04  
196.1  
196  
61  
60  
59  
58  
57  
56  
55  
54  
53  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
195.9  
195.8  
195.7  
195.6  
195.5  
195.4  
195.3  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
7
TXD3XGGI2xx  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Model Name  
Operating Temperature  
Distance  
Color  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
Extended  
TXD3XGGI2E00052G  
TXD3XGGI2E00051G  
TXD3XGGI2E00050G  
TXD3XGGI2E00049G  
TXD3XGGI2E00048G  
TXD3XGGI2E00047G  
TXD3XGGI2E00046G  
TXD3XGGI2E00045G  
TXD3XGGI2E00044G  
TXD3XGGI2E00043G  
TXD3XGGI2E00042G  
TXD3XGGI2E00041G  
TXD3XGGI2E00040G  
TXD3XGGI2E00039G  
TXD3XGGI2E00038G  
TXD3XGGI2E00037G  
TXD3XGGI2E00036G  
TXD3XGGI2E00035G  
TXD3XGGI2E00034G  
TXD3XGGI2E00033G  
TXD3XGGI2E00032G  
TXD3XGGI2E00031G  
TXD3XGGI2E00030G  
TXD3XGGI2E00029G  
TXD3XGGI2E00028G  
TXD3XGGI2E00027G  
TXD3XGGI2E00026G  
TXD3XGGI2E00025G  
TXD3XGGI2E00024G  
TXD3XGGI2E00023G  
TXD3XGGI2E00022G  
TXD3XGGI2E00021G  
TXD3XGGI2E00020G  
TXD3XGGI2E00019G  
TXD3XGGI2E00018G  
TXD3XGGI2E00017G  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
- 5°C to +85°C  
1535.82  
1536.61  
1537.40  
1538.19  
1538.98  
1539.77  
1540.56  
1541.35  
1542.14  
1542.94  
1543.73  
1544.53  
1545.32  
1546.12  
1546.92  
1547.72  
1548.51  
1549.32  
1550.12  
1550.92  
1551.72  
1552.52  
1553.33  
1554.13  
1554.94  
1555.75  
1556.55  
1557.36  
1558.17  
1558.98  
1559.79  
1560.61  
1561.42  
1562.23  
1563.05  
1563.86  
195.2  
195.1  
195.0  
194.9  
194.8  
194.7  
194.6  
194.5  
194.4  
194.3  
194.2  
194.1  
194.0  
193.9  
193.8  
193.7  
193.6  
193.5  
193.4  
193.3  
193.2  
193.1  
193.0  
192.9  
192.8  
192.7  
192.6  
192.5  
192.4  
192.3  
192.2  
192.1  
192.0  
191.9  
191.8  
191.7  
52  
51  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Color  
Model Name  
Operating Temperature  
Distance  
Industrial  
Industrial  
Industrial  
Industrial  
TXD3XGGI2I00061G  
TXD3XGGI2I00060G  
TXD3XGGI2I00059G  
TXD3XGGI2I00058G  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
1528.77  
1529.55  
1530.33  
1531.12  
196.1  
196  
61  
60  
59  
58  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
195.9  
195.8  
Oplink Communications, Inc  
S0330. Rev.04. (web) 2013-01-09  
8
TXD3XGGI2xx  
Center  
Wavelength  
(nm)  
ITU  
Frequency  
(THz)  
Wavelength  
Reference  
Latch  
Color  
Model Name  
Operating Temperature  
Distance  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
Industrial  
TXD3XGGI2I00057G  
TXD3XGGI2I00056G  
TXD3XGGI2I00055G  
TXD3XGGI2I00054G  
TXD3XGGI2I00053G  
TXD3XGGI2I00052G  
TXD3XGGI2I00051G  
TXD3XGGI2I00050G  
TXD3XGGI2I00049G  
TXD3XGGI2I00048G  
TXD3XGGI2I00047G  
TXD3XGGI2I00046G  
TXD3XGGI2I00045G  
TXD3XGGI2I00044G  
TXD3XGGI2I00043G  
TXD3XGGI2I00042G  
TXD3XGGI2I00041G  
TXD3XGGI2I00040G  
TXD3XGGI2I00039G  
TXD3XGGI2I00038G  
TXD3XGGI2I00037G  
TXD3XGGI2I00036G  
TXD3XGGI2I00035G  
TXD3XGGI2I00034G  
TXD3XGGI2I00033G  
TXD3XGGI2I00032G  
TXD3XGGI2I00031G  
TXD3XGGI2I00030G  
TXD3XGGI2I00029G  
TXD3XGGI2I00028G  
TXD3XGGI2I00027G  
TXD3XGGI2I00026G  
TXD3XGGI2I00025G  
TXD3XGGI2I00024G  
TXD3XGGI2I00023G  
TXD3XGGI2I00022G  
TXD3XGGI2I00021G  
TXD3XGGI2I00020G  
TXD3XGGI2I00019G  
TXD3XGGI2I00018G  
TXD3XGGI2I00017G  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
- 40°C to +85°C  
1531.90  
1532.68  
1533.47  
1534.25  
1535.04  
1535.82  
1536.61  
1537.40  
1538.19  
1538.98  
1539.77  
1540.56  
1541.35  
1542.14  
1542.94  
1543.73  
1544.53  
1545.32  
1546.12  
1546.92  
1547.72  
1548.51  
1549.32  
1550.12  
1550.92  
1551.72  
1552.52  
1553.33  
1554.13  
1554.94  
1555.75  
1556.55  
1557.36  
1558.17  
1558.98  
1559.79  
1560.61  
1561.42  
1562.23  
1563.05  
1563.86  
195.7  
195.6  
195.5  
195.4  
195.3  
195.2  
195.1  
195.0  
194.9  
194.8  
194.7  
194.6  
194.5  
194.4  
194.3  
194.2  
194.1  
194.0  
193.9  
193.8  
193.7  
193.6  
193.5  
193.4  
193.3  
193.2  
193.1  
193.0  
192.9  
192.8  
192.7  
192.6  
192.5  
192.4  
192.3  
192.2  
192.1  
192.0  
191.9  
191.8  
191.7  
57  
56  
55  
54  
53  
52  
51  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
Red  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
40km  
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu-  
nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements  
of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc.  
© 2013, Oplink Communications, Inc.  
S0330. Rev.04. (web) 2013-01-09  
9

相关型号:

TXD3XGGI2C00042G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00043G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00044G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00045G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00046G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00047G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00048G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00049G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00050G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00051G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00052G

Transceiver with Digital Diagnostics
OPLINK

TXD3XGGI2C00053G

Transceiver with Digital Diagnostics
OPLINK