BAH [PAIRUI]
DC-DC Converter;DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
FEATURES:
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
5 years warranty
1500Vdc isolation voltage
Output current up to 60A
Efficiency up to 93%
Operating temperature range -40°C to +85°C
Under voltage, over current, short circuit,
over voltage protection
Remote on/off
ꢀ
ꢀ
Adjustable output voltage
Input voltage
Output voltage
(Vdc)
Output current
Efficiency
Typ.
Model
(Vdc)
(A)
2.5
2.5
2.5
2.5
3.3
3.3
3.3
3.3
3.3
3.3
5.0
5.0
5.0
5.0
12.0
30.0
40.0
50.0
60.0
15.0
25.0
30.0
40.0
50.0
60.0
15.0
20.0
30.0
40.0
25.0
88%
90%
89%
87%
91%
92%
93%
89%
89%
89%
94%
92%
93%
92%
93%
BAH48-25V30
BAH48-25V40
BAH48-25V50
BAH48-25V60
BAH48-33V15
BAH48-33V25
BAH48-33V30
BAH48-33V40
BAH48-33V50
BAH48-33V60
BAH48-50V15
BAH48-50V20
BAH48-50V30
BAH48-50V40
BAH48-120V25
Notes:
48(36~72)
1. Other input and output models may available on request;
2. You may request for the models with heatsink, plus “R” in the suffix, e.g. BAH48-25V30R.
ELECTRICAL
Input voltage range
Remote control
48Vdc
36-72Vdc
OFF: High level or left close
ON: Low level or grounded
ON: High level or left open
OFF: Low level or grounded
50-300W
Negative logic
Positive logic
Output power
Input voltage range
www.pairuigroup.com
Page: 1 / 4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
ELECTRICAL
Output voltage
Single output
2.5/3.3/5/12Vdc
±1%
Output voltage accuracy
Output voltage adjustable
Line regulation
Input voltage range
Positive
-20% - +10%
±0.2%
Full load
Load regulation
10%-100% full load
±0.5%
Dynamic response
25%-50%-75% load capability
∆Vo/∆t: ±4.0%/500μs
(transient/recovery time)
Ripple and noise
Parallel test, 20MHz wide range
Typical value
180mVp-p max.
250KHz typ.
1500Vdc
Operating frequency
Input to output
Input to case
Isolation voltage
1050Vdc
Output to case
---
500Vdc
Isolation resistance
Safety
10MΩ
IEC-60950-1, UL-60950-1
EN-60950-1, GB4943
300ppm
---
Temperature coefficient
Operating temperature range
Storage temperature range
Over temperature protection
Under voltage protection
Over current protection
Short circuit protection
Over voltage protection
Relative humidity
---
Auxiliary heat sink
-40°C to +85°C
-40°C to +125°C
110°C typ.
Yes
---
Typical
---
---
Yes
---
Yes
---
Yes
---
95% max.
Hole package
2x106Hrs
Packing
---
MTBF
Bellcore TR-332, 25°C
Notes: Unless otherwise specified, all the parameters of the test conditions are as follows: ambient temperature
25 , the nominal input voltage, pure resistive nominal load.
www.pairuigroup.com
Page: 2 / 4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
MECHANICAL
WITHOUT HEATSINK
WITH HEATSINK
PCB LAYOUT
CONNECTION
PIN #
SINGLE
-Vin
FG
1
2
3
REM
+Vin
GND
-S
4
5
6
7
8
TRIM
+S
9
+Vo
Note:
* Unit is mm(inch).
DERATING CURVE
EFFICIENCY CURVE
www.pairuigroup.com
Page: 3 / 4
Date: 01/23/2014
DC-DC Converter
Bricks, Open/Enclosed
BAH SERIES, 1/2 BRICK, UP TO 300W
NOTES
RECOMMENDED TEST AND APPLICATION CIRCUIT
NOTES
1. TVS&FUSE be helpful with over voltage protection and inrush limiting. Recommended FUSE better be 1.5~2times of
the rated current .
2. The input filter capacitor C6 could select the aluminum electrolytic capacitors or tantalum capacitors, and the
withstand voltage should be greater than the highest input voltage. Recommended capacitor should be between
22μF~100μF.
3. C1,C2 for the input filter capacitor,0.1~1μF high-frequency ceramics capacitor or chip capacitor are recommended.
The withstand voltage of output filter C5, C7 should be greater than the highest output voltage. Recommended
capacitor of C7 better within 100μF and C5 connected with the chip to reduce the input voltage peak, recommended
0.1~1μF high-frequency ceramics capacitor or chip capacitor.
www.pairuigroup.com