Specifications  
AC-DC Din Rail Mounted Power Supply  
IS-30 Series, 30W  
PAIRUI ELECTRONICS  
No. 545 Museum Road  
Yangzhou, Jiangsu  
China 225009  
2019  
Tel: 86 (514) 8279 1592  
Fax: 86 (514) 8769 3159  
din rail power supply  
PRODUCT SPECIFICATION  
AC-DC Din Rail Mountable Power Supply  
IS-30 SERIES, SINGLE PHASE INPUT  
Features  
3 Year Warranty  
Universal Input 90~264Vac  
100% Full Load Burn-in Test  
Cooling by Free Air Convection  
All Round Protections: Short Circuit, Over Voltage,  
Over Current, Over Temperature  
LED Indicator for DC Power On  
LED Indicator for DC Low  
Applications  
Electrical  
-
IS 30 24  
Output Voltage(VDC)  
Output Power(W)  
Series Name  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:1/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Electrical  
Efficiency  
Certificate  
Nominal  
Part Number  
Output  
Voltage  
Output  
Current  
Ripple  
(Typ.)  
Input Voltage  
Min  
Typ  
IS30-5  
IS30-12  
IS30-15  
IS30-24  
100-240VAC  
100-240VAC  
100-240VAC  
100-240VAC  
5V  
5A  
32mV  
42mV  
45mV  
46mV  
75%  
78% CE, FCC, CB, UL, CUL  
12V  
15V  
24V  
2.5A  
2.0A  
1.3A  
81%  
78%  
85%  
83% CE, FCC, CB, UL, CUL  
82%  
CE  
87% CE, FCC, CB, UL, CUL  
NOTE:  
1. The ripple values are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire termin-  
ated with 0.1uF & 47uF parallel capacitor under ambient temperature 25at rated input voltage and  
rated load;  
2. The efficiency values are measured under ambient temperature 25at rated input voltage and rat-  
ed load.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:2/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
INPUT  
PARAMETER  
CONDITIONS  
MIN  
90  
TYP  
MAX  
264  
63  
UNITS  
Vac  
Input voltage  
Input frequency  
Input current  
47  
Hz  
Full load, Vin=115Vac  
Full load, Vin=230Vac  
0.65  
0.35  
A
A
Cold start, Vin=115Vac  
Cold start, Vin=230Vac  
30  
60  
A
A
1. This product is built in inrush limiting circuit to protect the circuit  
from surge current damages when the power is turned on. Malfunction  
can occur by repeating the input voltage on and off rapidly. Therefore,  
sufficient interval should be given between turning on and off the  
power;  
Inrush current  
2. To avoid connecting the switch or fuse to input terminal(outside of  
the power supply), more consideration should be given when selecting  
the parts that can endure the inrush current  
Stand-by power consumption Vin=230Vac  
1
2
W
Surge voltage  
L-N  
KV  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:3/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
OUTPUT  
PARAMETER  
CONDITIONS  
MIN  
TYP  
MAX  
UNITS  
Output voltage accuracy  
±1  
%
V
V
V
IS30-5  
4.5-5.3  
11.6-12.3  
13-16  
IS30-12  
IS30-15  
IS30-24  
23.5-24.5  
V
Output voltage adjustment  
range  
Output voltage can be adjusted within above range by V-ADJ. variable  
resistance inside of the power supply. When output voltage exceeds  
the range, the power supply will be in failure or get into over voltage  
protection mode. To avoid the case that the output voltage is higher  
than rated voltage, output current should be used under rated current  
Minimum load  
0
A
Line regulation  
Load regulation  
Turn-on delay time  
Hold up time  
Vin from 100Vac to 240Vac  
Vout from min. to max.  
Full load, Vin=115Vac  
Full load, Vin=115Vac  
1
1
%
%
100  
20  
ms  
ms  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:4/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Protection  
Short circuit  
Hiccup mode, it will recover automatically after fault condition is removed  
IS30-5: over voltage protection value 6.5V  
IS30-12: over voltage protection value 16V  
IS30-15: over voltage protection value 16V  
IS30-24: over voltage protection value 30V  
Over voltage  
(1) When output voltage exceeds above over voltage protection value or reversal  
voltage occurs, the protection will be started and the output voltage will be cut  
off in order to protect the power supply;  
(2) The power supply will recover after the power is turned on again  
IS30-5: over current protection value 6A  
IS30-12: over current protection value 4A  
IS30-15: over current protection value 4A  
IS30-24: over current protection value 2.2A  
Over current  
(1) When output voltage exceeds above over current protection value, the  
protection will be started and the output voltage will be cut off in order to  
protect the power supply;  
(2) The power supply will recover automatically after the fault condition is  
removed  
Over temperature protection value: 100±10℃  
Over  
temperature  
(1) When the ambient temperature exceeds above over temperature protection  
value, the protection will be started and the output voltage will be cut off in  
order to protect the power supply;  
(2) The power supply will recover after the power is turned on again  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:5/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Environment  
PARAMETER  
CONDITIONS  
MIN  
-35  
20  
TYP  
MAX  
+70  
95  
UNITS  
Ambient operating  
temperature  
Startup at rated voltage  
Non condensing  
Operating relative humidity  
Storagetemperature  
MTBF  
%
Humidity 5 ~ 95% RH  
-40  
200  
+85  
Fullload, 220Vac input, 25ambientꢀ  
temperature  
Khrs  
LED(Green)  
DC-OK led  
DC OK LED light will be ON when the power supply is properly  
operated  
LED(Red)  
DC Low LED light will be ON:  
(1) when output voltage is below 85%(±2.5%) from the rated output  
voltage;  
DC-Low led  
(2) when get over voltage, over current, over temperature and short  
circuit fault  
Cooling  
Free air convection  
Vertical  
Mounting method  
Dimension(W x H x D)  
Weight  
36.0 x 95.0 x 108.0mm  
(1.42 x 3.74 x 4.25inch)  
250g  
22pcs/7.5kg/0.7cuft/carton  
Carton size 620 x 260 x 175mm(LxWxH)  
Packing  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:6/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Safety/EMC  
Isolation voltage I/P-O/P:ꢀ3KVac, I/P-FG: 1.5KVac, O/P-FG: 1.5KVac  
Insulation  
100MΩ Max./500VDC  
resistance  
Safety  
EMC  
Design refer to UL60950-1, EN60950-1  
EN 55032:2015  
EN 61000-3-2:2014 (IEC 61000-3-2:2014)  
EN 61000-3-3:2013 (IEC 61000-3-3:2013)  
EN 55024:2010+A1:2015  
NOTE: Unless otherwise specified, all the above parameters are measured at ambient temperature of  
25andVin=100Vac to 240Vac.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:7/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Mechanical  
108±1.0  
36±1.0  
5 5.2 5  
5
Output Voltage  
Adjustment  
LED (DC OK)  
LED (DC LOW)  
DIN Rail  
(Width: 35mm)  
11.6  
LABEL  
PRINTING  
NAME PLATE  
SN code  
7.5  
7.5  
12.7  
95.3  
Unit: mm  
Tolerance: ±1.0  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:8/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Mechanical  
1
2
3
4
Marking  
No.  
Assignment  
1
2
3
4
5
6
7
/
/
/
DC(+) Output Terminal  
DC(-) Output Terminal  
V-ADJ.  
DC OK  
DC LOW  
AC(L) Input Terminal  
L
AC(N) Input Terminal  
N
AC Grounding Terminal  
DC Output voltage adjustment trimmer  
DC Output OK indication LED(Green)  
DC Output Low indication LED(Red)  
V-ADJ.  
DC OK  
L N  
DC LOW  
5
6
7
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:9/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Electrical Curve  
Derating Curve  
Static Characteristics  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
230V input  
110V input  
-35  
0
30  
50  
60  
70  
80  
90  
110 150 180 220 240 264  
Input Voltage(Vac)  
Ambient Temperature(℃)  
Block Diagram  
+V  
+V  
L
Inrush  
Current  
Limit  
Line  
Filter  
Rectifier  
Circuit  
Switching  
Device  
Rectifier  
Circuit  
Current  
Detect  
N
-V  
-V  
Error  
AMP  
FG  
PWM  
Control  
Circuit  
OVP  
Detect  
DC OK(Green)  
DC Low(Red)  
Output  
Detect  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:10/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Package  
Inner Box  
L 150 x W 130 x H 42mm  
Outer Carton  
L 620 x W 260 x H 185mm  
SERIES  
IS-30  
QTY/BOX  
1 piece  
QTY/CARTON  
22 boxes  
NET WEIGHT  
5.5kg/carton  
GROSS WEIGHT  
VOLUME  
7.5kg/carton  
0.7cuft/carton  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:11/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
1. Series Operation  
LOAD  
LOAD  
LOAD  
L N  
L N  
L N  
L N  
Series Operation A  
Series Operation B  
Note:  
1. Series operation can be connected as shown in above;  
2. Load current should be less than the current value of the product with the lowest output  
current specified at the product specification with the power supply at series connection.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:12/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
2. Parallel Operation  
LOAD  
LOAD  
L N  
L N  
L N  
L N  
Parallel Operation B  
(Unable to use)  
Parallel Operation A  
(Unable to use)  
LOAD  
L N  
L N  
Parallel Operation C  
(Backup)  
Note:  
1. Parallel operation should be composed with the same products, while the connection sho-  
uld be as shown as “Parallel operation C”;  
2. In parallel operation C, current capacity cannot be increased, while it should be used for  
backup only. Moreover, diode that is to be added during parallel operation should be selected  
after considering it’s voltage drop, output voltage and current capacity.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:13/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
3. Mounting Method  
(1) How to fix  
Firstly hang A part on the top of Rail as shown in below, then push the power supply into B di-  
rection to fix it.  
(2) How to remove  
Remove the power supply to D direction, pulling C part by using tools, such as a screwdriver,  
to downward direction.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:14/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
3. Mounting Method  
(3) Mounting Spacing  
Mounting method should be considered with airflow. Leave enough space between the units  
when several units are mounted together. Forced air cooling makes protection against heat  
better.  
25mm  
or more  
AIR  
L N  
L N  
AIR  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:15/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
4. Cautions  
(1) Please confirm if the capacity of the product is suitable for your intended application be-  
fore putting it in use;  
(2) Only the rated input voltage specified on the product should be used;  
(3) Only the wires with rated capacity should be connected to this product, as allowable vol-  
tage and current is varied according to each type of wire;  
(4) Ground terminal of the power supply must be grounded before use to prevent electric sh-  
ock or electromaganetic interference;  
(5) Be cautions to keep the product clean as foreign matter near the input & output terminal  
or inside if the product could cause series damages;  
(6) If a fuse installed in the product blows off, the product should experience damages not  
only to the fuse but also to other parts as well. Therefore, the product is to be required for  
maintenance work from customer service department as well as replacement of the fuse;  
(7) Due to constant leakage current flows within the product, extra caution should be made  
if multiple number of products are used connecting to each other as total leakage current c-  
ould be amounted beyond the capacity;  
(8) Be sure to avoid any physical contact with the product since some of the parts inside of  
the product are being functioned at high voltage, which could cause serious electric shock;  
(9) For the purpose of safety as well as reliability of the product, please avoid using the pro-  
duct at the following sites:  
- A place near water or fire  
- A place with high room temperature and poor ventilation  
- A place with a presence of foreign subject or dust  
- A place near volatile or flammable compounds  
- A place with high humidity  
- A place vulnerable for vibration or shock  
(10) Do not inspect or repair the product while the power is applied;  
(11) Unauthorized modification should be avoided in order to prevent series injury or physic-  
al loss due to any malfunction;  
(12) In case of power outage while in operation, be sure to turn off the power supply.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:16/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Application Note  
5. Warranty  
(1) Repair service will be provided for free upon any mechanical, technical or functional de-  
fects during the guaranteed warranty, however, any defects or malfunction due to internati-  
onal infliction or negligence by customers will be repaired at the customer’s expense;  
(2) Guaranteed warranty of the product runs for 3 years, while appearance and specification  
of the product is subject for change without any prior notification for the purpose of quality  
improvement of the product.  
PAIRUI ELECTRONICS  
www.pairuigroup.com  
Page:17/17  
Updated 2019-V1.0-0318  
din rail power supply  
PRODUCT SPECIFICATION  
Update Record  
Date  
Version  
Updated Content  
File created  
Updated By  
Approved By  
2016/08/30 2016-V1.0-0830  
2016/12/06 2016-V1.0-1206  
2019/03/18 2019-V1.0-0318  
Correct resistance unit  
File updated  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY