AHN211X0 [PANASONIC]

Power/Signal Relay, DPDT, Momentary, 1400mW (Coil), 5A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;
AHN211X0
型号: AHN211X0
厂家: PANASONIC    PANASONIC
描述:

Power/Signal Relay, DPDT, Momentary, 1400mW (Coil), 5A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总4页 (文件大小:152K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
without screw  
pending terminal socket  
pending  
SLIM AND COMPACT RELAY  
FOR WIDER APPLICATIONS  
HN-RELAYS  
FEATURES  
• Slim and compact size  
• Slim screw terminal socket  
Utilizes relay-securing hook for easy relay  
removal.  
20% more compact (width and height)  
than existing model* (with the condition of  
screw terminal socket for DIN rail)  
*Compared with our HJ relay.  
• High reliability and reasonable price  
Uses gold-flashed contacts for highly  
reliable contact.  
TYPICAL APPLICATIONS  
Control panels  
Machine tools  
• Environmentally friendly  
Forming machines  
Commercial equipment  
Agricultural machines  
Vending machines  
In consideration of the environment,  
cadmium-free contacts are used. Also  
supports lead-free.  
(Both relays and screw terminal socket.)  
SPECIFICATIONS  
Contacts  
Characteristics  
Contact arrangement  
2 Form C  
50mΩ  
Max. operating speed  
Initial insulation resistance*1  
20 cpm (at max. rating)  
Min. 1,000 Mat 500 V DC  
1,000 Vrms for 1 min.  
3,000 Vrms for 1 min.  
5,000 Vrms for 1 min.  
Max. 15 ms*4  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
Between open contacts  
Initial  
Contact material  
Gold-flashed silver alloy  
breakdown Between contact sets  
Nominal switching capacity 5A 250V AC, 5A 30V DC  
voltage*2  
Between contact and coil  
Max. switching power  
Max. switching voltage  
Max. switching current  
Min. switching current*9  
1,250 VA, 150W  
250V AC, 30V DC  
5 A  
Rating  
(resistive  
load)  
Operate time*3 (at nominal voltage)  
Release time (without diode)*3  
(at nominal voltage)  
Max. 10 ms*4  
1V 1 mA  
AC: 107  
DC: 2×107  
Temperature rise, max. (at 70°C)  
(at nominal voltage)  
60°C  
Mechanical  
(at 300 cpm)  
Expected life  
(min.  
operations)  
Functional*5  
Destructive*6  
Min. 100 m/s2 {10 G}  
Min. 1,000 m/s2 {100 G}  
Shock resistance  
Electrical (at 20 cpm)  
(resistive load)  
105  
10 to 55 Hz at double  
amplitude of 1.5 mm  
Functional*7  
Vibration resistance  
Coil  
10 to 55 Hz at double  
amplitude of 1.5 mm  
Destructive  
Nominal operating power  
0.53W 0.9VA  
Remarks  
Conditions for operation,  
transport and storage*8  
(Not freezing and  
condensing at low  
temperature)  
Ambient  
temp.  
–40°C to +70°C  
–40°F to +158°F  
*
*
*
*
*
*
*
*
*
*
Specifications will vary with foreign standards certification ratings.  
1
2
3
4
5
6
7
8
9
Measurement at same location as “Initial breakdown voltage” section  
Detection current: 10mA  
Excluding contact bounce time  
For the AC coil types, the operate/release time will differ depending on the phase.  
Half-wave pulse of sine wave: 11ms; detection time: 10µs  
Half-wave pulse of sine wave: 6ms  
Humidity  
5 to 85% R.H.  
Unit weight  
Approx. 17g .60 oz  
Detection time: 10µs  
Refer to 4. Conditions for operation, transport and storage mentioned in NOTES  
This value can change due to the switching frequency, environmental conditions  
and desired reliability level, therefore it is recommended to check this with the  
actual load.  
ORDERING INFORMATION  
Ex. AHN  
Contact arrangement  
2: 2 Form C  
Terminal arrangement  
Type classification  
0: Standard  
1: With LED indication  
2: With diode  
Coil voltage  
1: AC plug-in type  
2: DC plug-in type  
05: 5, 06: 6, 12: 12, 24: 24, 48: 48 V  
X0: 100/110 V AC, 100 V DC  
X1: 110/120 V AC, 110 V DC  
3: With LED indication, diode  
Y0: 200/220 V AC, Y2: 220/240 V AC  
Note: Products conform to UL/C-UL and VDE, as standard (pending).  
HN RELAY  
ASCT1B263E ’03.4  
New  
HN(AHN2)  
TYPES  
1. Plug-in type  
2. Plug-in with LED indication type  
2 Form C  
Part No.  
2 Form C  
Part No.  
Coil voltage  
Coil voltage  
5V DC  
6V DC  
AHN22005  
AHN22006  
AHN22012  
AHN22024  
AHN22048  
AHN220X0  
AHN220X1  
AHN21012  
AHN21024  
AHN210X0  
AHN210X1  
AHN210Y0  
AHN210Y2  
5V DC  
6V DC  
AHN22105  
AHN22106  
AHN22112  
AHN22124  
AHN22148  
AHN221X0  
AHN221X1  
AHN21112  
AHN21124  
AHN211X0  
AHN211X1  
AHN211Y0  
AHN211Y2  
12V DC  
12V DC  
24V DC  
24V DC  
48V DC  
48V DC  
100V DC  
110V DC  
12V AC  
100V DC  
110V DC  
12V AC  
24V AC  
24V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
Note: Packing quantity; Inner carton: 50 pcs, Outer carton: 500 pcs.  
Note: Packing quantity; Inner carton: 50 pcs, Outer carton: 500 pcs.  
3. Plug-in with diode type  
4. Plug-in with diode and LED indication type  
2 Form C  
2 Form C  
Coil voltage  
Part No.  
Coil voltage  
Part No.  
5V DC  
6V DC  
AHN22205  
AHN22206  
AHN22212  
AHN22224  
AHN22248  
AHN222X0  
AHN222X1  
5V DC  
6V DC  
AHN22305  
AHN22306  
AHN22312  
AHN22324  
AHN22348  
AHN223X0  
AHN223X1  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
Note: Packing quantity; Inner carton: 50 pcs, Outer carton: 500 pcs.  
Note: Packing quantity; Inner carton: 50 pcs, Outer carton: 500 pcs.  
5. Screw terminal socket  
Type  
No. of channels  
2 channels  
Item  
Part No.  
AHNA21  
For DIN rail assembly  
HN2 screw terminal socket  
Notes) 1. Packing quantity: 10pcs. (Inner carton), 100pcs. (Outer carton)  
2. Products conform to UL, C-UL, as standard.  
3. In order to prevent breakage and disguring, the screw tightening torque for the terminal socket should be within the range of 0.5 to 0.8 N·m.  
4. When attaching directly to a chassis, please use an M3 × 16 metric coarse screw thread.  
5. To prevent damage and deformity, please use the relay-securing hook at 10 N or less.  
COIL DATA (at 20°C 68°F)  
DC coils  
Pick-up voltage,  
V DC (max.)  
(Initial)  
Drop-out voltage, Nominal coil current,  
Coil  
resistance, Ω  
(±10%)  
Coil voltage  
V DC  
Nominal operating  
power, W  
Max. allowable  
voltage, V DC  
V DC (min.)  
(Initial)  
mA  
(±20%)  
5
6
3.5  
4.2  
8.4  
16.8  
33.6  
70  
0.5  
0.6  
105.9  
88.4  
44.2  
22.1  
11  
47  
68  
8.5  
10.2  
20.4  
40.8  
81.6  
170  
187  
12  
24  
48  
100  
110  
0.12  
0.24  
0.48  
10  
270  
1,090  
4,350  
18,870  
22,830  
0.53  
5.3  
77  
11  
4.8  
AC coils (50/60Hz)  
Nominal coil current, mA  
Nominal operating  
power, VA  
Pick-up voltage,  
V AC (max.)  
(Initial)  
Drop-out voltage,  
V AC (min.)  
(Initial)  
Coil voltage  
V AC  
Max. allowable  
voltage, V AC  
(±20%)  
50Hz  
93  
60Hz  
75  
50Hz  
60Hz  
12  
9.6  
3.6  
16.8  
24  
19.2  
7.2  
46.5  
37.5  
33.6  
100/110  
110/120  
200/220  
220/240  
80/88  
30/33  
33/36  
60/66  
66/72  
11.0/13.0  
10.0/11.8  
5.5/6.5  
5.0/5.9  
9.0/10.6  
8.2/9.7  
4.5/5.3  
4.1/4.8  
140/154  
154/168  
280/308  
308/336  
Approx.  
1.1 to 1.4  
Approx.  
0.9 to 1.2  
88/96  
160/176  
176/192  
2
HN(AHN2)  
mm inch  
DIMENSIONS  
1. Plug-in type 2 Form C  
Schematic (Bottom view)  
Standard type  
Max. 29  
Max. 1.142  
Max. 13  
Max. .512  
1
2
3
4
8
7
6
5
Max. 28  
Max. 1.102  
With LED AC type  
With LED DC type  
1
2
3
4
1
2
3
4
+
6
.236  
8
7
6
5
8
7
6
5
2.6  
.102  
0.5  
.020  
2.6  
.102  
0.5  
.020  
With Diode type  
With Diode and LED type  
1
2
3
4
1
2
3
4
+
+
8
7
6
5
8
7
6
5
8.9  
.350  
7.5  
.295  
5
5
.197 .197  
19.4  
.764  
Dimension :  
Max. 1mm .039 inch:  
1 to 3mm .039 to .118 inch: ±0.2 ±.008  
Tolerance  
±0.1 ±.004  
Min. 3mm .118 inch:  
±0.3 ±.012  
2. Screw terminal socket  
Schematic (Top view)  
1
8
3
6
4
5
2
7
71  
2.795  
4
.157  
6.45  
.254  
Mounting hole dimensions  
29  
1.142  
19  
.748  
4.2 .165 dia. hole  
4
.157  
M3 .118 or  
3.2 .126 dia. hole  
35.4  
1.394  
30±0.1  
1.181±.004  
17.5  
.689  
General tolerance: ±0.5 ±.020  
REFERENCE DATA  
1. Max. switching capacity  
2-(1). Coil temperature rise (AC type)  
2-(2). Coil temperature rise (DC type)  
Measured portion: Inside the coil  
Measured portion: Inside the coil  
Ambient temperature: 23°C 73°F  
Ambient temperature: 30°C 86°F  
70  
10  
5
120  
5A  
0A  
60  
5A  
0A  
100  
80  
60  
40  
20  
0
50  
40  
30  
20  
AC resistive load  
1
0.5  
0.4  
0.3  
DC resistive load  
0.2  
10  
0
10  
20 30 50 100  
Contact voltage, V  
250  
80 90 100 110 120 130 140  
Coil applied voltage, %V  
80 90 100 110 120 130 140  
Coil applied voltage, %V  
3
HN(AHN2)  
NOTES  
1. Coil operating power  
4. Conditions for operation, transport  
and storage  
1) Ambient temperature, humidity, and  
atmospheric pressure during usage,  
transport, and storage of the relay:  
(1) Temperature:  
40 to +70°C 40 to +158°F  
(2) Humidity: 5 to 85% RH  
(Avoid freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
5. About the relay-securing hook  
1) Installation of the securing hook is  
easily performed by pressing upward in  
the direction of the arrows.  
To ensure proper operation, the voltage  
applied to both terminals of the coil should  
be ±5% (at 20°C 68°F) the rated operating  
voltage of the coil. Also, be aware that the  
pick-up and drop-out voltages will  
uctuate depending on the ambient  
temperature and operating conditions.  
2. LED indications  
The light of the light emitting diode is what  
displays operation. If voltage remains  
after relay dropout, the LED might  
illuminate briey.  
Humidity, %R.H.  
2) Removal of the securing hook is easily  
performed by releasing the hook and  
pressing down, as shown in the gure.  
3. Switching lifetime  
The switching lifetime is dened under the  
standard test condition specied in the  
JIS* C 5442-1996 standard (temperature  
15 to 35°C 59 to 95°F, humidity 25 to  
75%). Check this with the real device as it  
is affected by coil driving circuit, load type,  
activation frequency, activation  
phase,ambient conditions and other  
factors.  
Also, be especially careful of loads such  
as those listed below.  
(1) When used for AC load-operating and  
the operating phase is synchronous.  
Rocking and fusing can easily occur due  
to contact shifting.  
(2) High-frequency load-operating  
When high-frequency opening and  
closing of the relay is performed with a  
load that causes arcs at the contacts,  
nitrogen and oxygen in the air is fused by  
the arc energy and HNO3 is formed. This  
can corrode metal materials.  
Three countermeasures for these are  
listed here.  
1. Incorporate an arc-extinguishing  
circuit.  
85  
Tolerance range  
(Avoid freezing when  
used at temperatures  
lower than 0°C 32°F)  
(Avoid  
condensation when  
used at temperatures  
higher than 0°C 32°F)  
5
40  
40  
0
+32  
+70  
+158  
Temperature, °C °F  
(3) Atmospheric pressure: 86 to 106 kPa  
Temperature and humidity range for  
usage, transport, and storage:  
2) Condensation  
Condensation forms when there is a  
sudden change in temperature under high  
temperature and high humidity conditions.  
Condensation will cause deterioration of  
the relay insulation.  
6. Diode characteristics  
1) Reverse breakdown voltage:  
90V (5 to 48V DC type)  
250V (100, 110V DC type)  
7. Diode type  
Since the diode inside the relay coil are  
designed to absorb the counter emf, the  
element may be damaged if a large surge,  
etc., is applied to the diode.  
If there is the possibility of a large surge  
voltage from the outside, please  
implement measures to absorb it.  
3) Freezing  
Condensation or other moisture may  
freeze on the relay when the  
temperatures is lower than 0°C 32°F.  
This causes problems such as sticking of  
movable parts or operational time lags.  
4) Low temperature, low humidity  
environments  
The plastic becomes brittle if the relay is  
exposed to a low temperature, low  
humidity environment for long periods of  
time.  
2. Lower the operating frequency  
3. Lower the ambient humidity  
These materials are printed on ECF pulp.  
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.  
Please contact ..........  
Matsushita Electric Works, Ltd.  
Automation Controls Company  
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan  
Telephone: Japan (81) Osaka (06) 6908-1050  
Facsimile: Japan (81) Osaka (06) 6908-5781  
http://www.nais-e.com/  
COPYRIGHT © 2003 All Rights Reserved  
ASCT1B263E 200304-3YT  
Specifications are subject to change without notice.  

相关型号:

AHN211X0N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN211X1

Power/Signal Relay, DPDT, Momentary, 1400mW (Coil), 5A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

AHN211X1N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN211Y0

Power/Signal Relay, DPDT, Momentary, 1400mW (Coil), 5A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

AHN211Y0N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN211Y2

Power/Signal Relay, DPDT, Momentary, 1400mW (Coil), 5A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

AHN211Y2N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN22005

Power/Signal Relay, DPDT, Momentary, 0.106A (Coil), 5VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

AHN22005N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN22006

Power/Signal Relay, DPDT, Momentary, 0.088A (Coil), 6VDC (Coil), 530mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

AHN22006N

Relay for control panel of 1c 10A, 2c 5A and 1a 16A
PANASONIC

AHN22006N

Slim and compact size