ALQ124 [PANASONIC]

1 Form A/1 Form C 10A Small power relays;
ALQ124
型号: ALQ124
厂家: PANASONIC    PANASONIC
描述:

1 Form A/1 Form C 10A Small power relays

文件: 总6页 (文件大小:92K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1 Form A/1 Form C 10A  
Small power relays  
LQ RELAYS (ALQ)  
FEATURES  
TYPICAL APPLICATIONS  
w
Ne  
1. Miniature size and small: 10(W) ×  
20(L) × 16(H) mm .394(W) × .787(L) ×  
.630(H) inch  
1. Household appliances  
Air conditioners, Refrigerators,  
Fan heaters, Microwave ovens, Inverter  
and Hot water units  
2. Compact with high capacity:  
1 Form A and 1 Form C, 10 A  
3. Ambient temperature:  
–40°C to +85°C –40°F to 185°F  
4. High surge voltage: 8,000 V  
between contacts and coil  
5. High breakdown voltage: 4,000 V  
between contacts and coil  
RoHS compliant  
* Protective construction: Flux-resistant type  
ORDERING INFORMATION  
ALQ  
Contact arrangement  
1: 1 Form C  
3: 1 Form A  
Coil insulation class  
Nil: Class B insulation  
F: Class F insulation  
Nominal coil voltage (DC)  
05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V  
TYPES  
1 Form A  
Part No.  
ALQ305  
ALQ306  
ALQ309  
ALQ312  
ALQ318  
ALQ324  
1 Form C  
Part No.  
ALQ105  
ALQ106  
ALQ109  
ALQ112  
ALQ118  
ALQ124  
Nominal coil voltage  
5V DC  
6V DC  
9V DC  
12V DC  
18V DC  
24V DC  
Standard packing: Carton 100 pcs., Case 500 pcs.  
ASCTB92E 201206-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  
LQ (ALQ)  
RATING  
1. Coil data  
Nominal operating  
current  
[ 10%] (at 20°C 68°F)  
Nominal operating  
power  
(at 20°C 68°F)  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage  
(at 20°C 68°F)  
Drop-out voltage  
(at 20°C 68°F)  
Coil resistance  
[ 10%] (at 20°C 68°F)  
Max. applied voltage  
5V DC  
6V DC  
40.0mA  
33.3mA  
22.2mA  
16.7mA  
11.1mA  
8.3mA  
125  
180  
180% of nominal voltage  
(at 20°C 68°F)  
75%V or less of  
nominal voltage  
(Initial)  
5%V or more of  
nominal voltage  
(Initial)  
9V DC  
405  
1 Form A  
200mW  
400mW  
130% of nominal voltage  
(at 85°C 185°F)*4  
12V DC  
18V DC  
24V DC  
5V DC  
720  
1,620  
2,880  
80.0mA  
66.7mA  
44.4mA  
33.3mA  
22.2mA  
16.7mA  
62.5Ω  
90  
202.5Ω  
360  
810  
6V DC  
150% of nominal voltage  
(at 20°C 68°F)  
110% of nominal voltage  
(at 85°C 185°F)*4  
75%V or less of  
nominal voltage  
(Initial)  
5%V or more of  
nominal voltage  
(Initial)  
9V DC  
1 Form C  
12V DC  
18V DC  
24V DC  
1,440  
2. Specifications  
Characteristics  
Item  
Specifications  
Arrangement  
1 Form A  
1 Form C  
Contact  
Contact resistance (Initial)  
Contact material  
Max. 100m(By voltage drop 6 V DC 1 A)  
AgNi type  
N.O. side:  
10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC  
N.C. side:  
3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC  
Nominal switching capacity (resistive load)  
Max. switching power (resistive load)  
5 A 30 V DC, 10 A 125 V AC, 5 A 250 V AC  
150 W, 1,250 VA  
N.O. side: 150 W, 1,250 VA  
N.C. side: 30 W, 500 VA  
Rating  
Max. switching voltage  
250 V AC  
N.O.: 10 A (125V AC), N.C.: 3 A (125V AC)  
200 mW 400 mW  
Max. switching current  
Nominal operating power  
Min. switching capacity (reference value)*1  
100 mA, 5 V DC  
Insulation resistance (Initial)  
Min. 1,000 M(at 500 V DC) Measurement at same location as “Breakdown voltage” section.  
1,000 Vrms for 1 min.  
(Detection current: 10 mA)  
750 Vrms for 1 min.  
(Detection current: 10 mA)  
Between open contacts  
Between contact and coil  
Breakdown voltage  
(Initial)  
4,000 Vrms for 1 min. (Detection current: 10 mA)  
Electrical  
characteristics  
Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil; contact carrying  
current: 10A, at 85°C 185°F)  
Temperature rise (coil)*4  
Surge breakdown voltage*2  
(Between contact and coil)  
8,000 V (Initial)  
Operate time (at nominal voltage) (at 20°C 68°F)  
Release time (at nominal voltage) (at 20°C 68°F)  
Max. 20 ms (excluding contact bounce time.) (Initial)  
Max. 20 ms (excluding contact bounce time, with diode) (Initial)  
1 Form A: 294 m/s2, 1 Form C: 196 m/s2  
(Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)  
Functional  
Shock resistance  
Mechanical  
characteristics  
Destructive  
980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10µs.)  
10 to 55 Hz at double amplitude of 2.0 mm  
Functional  
Vibration resistance  
Destructive  
Expected life  
Conditions  
Unit weight  
Mechanical  
Min. 107 (at 180 times/min.)  
Ambient temperature: –40°C to +85°C –40°F to +185°F  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions for operation, transport and storage*3  
Max. operating speed  
20 times/min. (at nominal switching capacity)  
Approx. 7 g .25 oz  
* Specifications will vary with foreign standards certification ratings.  
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981  
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage  
conditions in NOTES.  
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with  
20°C 68°F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.  
ASCTB92E 201206-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  
LQ (ALQ)  
3. Expected electrical life  
Condition: Resistive load, at 20°C 68°F, at 20 times/min., with diode  
Type  
Switching capacity  
No. of operations  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
5×104  
5×104  
105  
1 Form A (at 20 times/min.)  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
5×104  
5×104  
105  
2×105  
2×105  
105  
N.O.  
N.C.  
1 Form C (at 20 times/min.)  
3 A 125 V AC  
2 A 250 V AC  
1 A 30 V DC  
REFERENCE DATA  
1.-(1) Max. switching capacity (1 Form A type)  
1.-(2) Max. switching capacity (1 Form C type)  
2. Life curve  
Ambient temperature: room temperature  
100  
100  
100  
AC resistive load N.O. side  
AC resistive load  
10  
5
10  
5
125V AC resistive load  
10  
3
2
AC resistive load N.C. side  
1
1
250V AC resistive load  
1
10  
100 250  
1,000  
10  
100 250  
Contact voltage, V  
1,000  
0
2
4
6
8
10  
Contact voltage, V  
Contact current, A  
3.-(1) Coil temperature rise (1 Form A type)  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
3.-(2) Coil temperature rise (1 Form C type)  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
4.-(1) Ambient temperature characteristics  
(1 Form A type)  
Contact carrying current: 5 A, 10 A  
70  
70  
400  
10 A at 85°C  
1
60  
60  
10 A at 85°C  
2
10 A at 70°C  
300  
50  
50  
10 A at 70°C  
5 A at 70°C  
40  
40  
200  
5 A at 85°C  
3
30  
20  
10  
0
30  
5 A at 70°C  
5 A at 85°C  
4
5
20  
10  
100  
6
7
0
100  
120  
140  
160  
180  
100 110 120 130 140 150 160  
0
20 30 40 50 60 70 80 90  
Ambient temperature, °C  
Coil applied voltage, %V  
Coil applied voltage, %V  
4.-(2) Ambient temperature characteristics  
(1 Form C type)  
Contact carrying current: 5 A, 10 A  
1 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 5 A)  
400  
2 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 10 A)  
300  
3 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 5 A)  
4 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 10 A)  
1
2
3
200  
4
5
100  
5 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 10 A)  
6
7
6 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 5 A)  
0
20 30 40 50 60 70 80 90  
Ambient temperature, °C  
7 Pick-up voltage  
ASCTB92E 201206-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  
LQ (ALQ)  
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/  
DIMENSIONS (mm inch)  
External dimensions  
Schematic (Bottom view)  
1 Form C  
CAD Data  
1 Form A  
1 Form A  
10  
.394  
20  
.787  
COM N.O.  
COM N.O.  
Coil  
Coil  
15.6  
.614  
N.C.  
0.4  
.016  
4.2  
.165  
7.62  
.300  
10.16  
.400  
0.3  
7.62  
.300  
7.62  
.300  
0.8  
0.5 dia.  
.020 dia.  
0.3  
.012  
.012  
.031  
PC board pattern (Bottom view)  
1FormC  
1 Form C  
1 Form A  
10  
.394  
20  
.787  
4-1.3 dia.  
5-1.3 dia.  
4-.051 dia.  
5-.051 dia.  
10.16  
.400  
7.62  
.300  
10.16  
.400  
7.62  
.300  
15.6  
.614  
7.62  
.300  
7.62  
.300  
0.4  
.016  
4.2  
.165  
2.54  
.100  
5.08  
.200  
7.62  
.300  
10.16  
2.54  
.100  
7.62  
.300  
.400  
0.3  
0.8  
.031  
0.5 dia.  
.020 dia.  
Tolerance: 0.1 .004  
.012  
0.8  
.031  
0.3  
.012  
0.3  
.012  
Dimension:  
Less than 1mm .039inch:  
General tolerance  
0.2 .008  
Min. 1mm .039inch less than 5mm .197 inch: 0.3 .012  
Min. 5mm .197 inch:  
0.4 .016  
SAFETY STANDARDS  
UL/C-UL (Recognized)  
Contact rating  
VDE (Certified)  
Item  
File No.  
E43028  
File No.  
Contact rating  
10A 125V AC  
5A 277V AC  
5A 30V DC  
40032836  
5A 250V AC (cosφ=1.0)  
10A 250V AC (cosφ=1.0)  
10A 250V AC (cosφ=0.4)  
5A 30V DC (0ms)  
1 Form A  
4FLA/4LRA 277V AC  
1/6 HP 125V AC  
1/6 HP 277V AC  
E43028  
<N.O.>  
40032836  
<N.O.>  
10A 125V AC  
5A 277V AC  
5A 30V DC  
4FLA/4LRA 277V AC  
1/6 HP 125V AC  
1/6 HP 277V AC  
<N.C.>  
5A 250V AC (cosφ=1.0)  
10A 250V AC (cosφ=1.0)  
10A 250V AC (cosφ=0.4)  
5A 30V DC (0ms)  
<N.C.>  
1 Form C  
3A 250V AC (cosφ=0.4)  
3A 125V AC  
2A 277V AC  
1A 30V DC  
Note) CSA standard: Certified by C-UL  
ASCTB92E 201206-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  
LQ (ALQ)  
NOTES  
Usage, transport and storage  
conditions  
Solder and cleaning conditions  
1) Please obey the following conditions  
when soldering automatically.  
(1) Preheating: Within 120°C 248°F  
(solder surface terminal portion) and  
within 120 seconds  
When highly frequent opening and  
closing of the relay is performed with a  
load that causes arcs at the contacts,  
nitrogen and oxygen in the air is fused by  
the arc energy and HNO3 is formed. This  
can corrode metal materials.  
Three countermeasures for these are  
listed here.  
• Incorporate an arc-extinguishing circuit.  
• Lower the operating frequency  
• Lower the ambient humidity  
5) This value can change due to the  
switching frequency, environmental  
conditions, and desired reliability level,  
therefore it is recommended to check this  
with the actual load.  
6) Heat, smoke, and even a fire may  
occur if the relay is used in conditions  
outside of the allowable ranges for the  
coil ratings, contact ratings, operating  
cycle lifetime, and other specifications.  
Therefore, do not use the relay if these  
ratings are exceeded.  
7) If the relay has been dropped, the  
appearance and characteristics should  
always be checked before use.  
8) Incorrect wiring may cause  
unexpected events or the generation of  
heat or flames.  
1) Temperature:  
–40 to +85°C –40 to +185°F  
2) Humidity: 5 to 85% RH  
(Avoid freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
3) Atmospheric pressure: 86 to 106 kPa  
Temperature and humidity range for  
usage, transport, and storage  
(2) Soldering iron: 260°C 5°C  
500°F 41°F (solder temperature) and  
within 6 seconds (soldering time)  
2) Do not use ultrasonic cleaning. This  
will adversely affect relay characteristics.  
When cleaning the relay, please use  
alcoholic solvents.  
Humidity, %RH  
Cautions for use  
1) For precautions regarding use and  
explanations of technical terminology,  
please refer to our web site.  
85  
Tolerance range  
(Avoid freezing (Avoid  
when used at condensation  
temperatures  
lower than  
0°C 32°F)  
(panasonic-electric-works.net/ac)  
2) To ensure good operation, please keep  
the voltage on the coil ends to 5% (at  
20°C 68°F) of the rated coil operation  
voltage. Also, please be aware that the  
pick-up voltage and drop-out voltage may  
change depending on the temperature  
and conditions of use.  
when used at  
temperatures  
higher than  
0°C 32°F)  
5
–40  
–40  
0
+32  
85  
+185  
Temperature, °C °F  
4) Condensation  
Condensation forms when there is a  
sudden change in temperature under  
high temperature and high humidity  
conditions. Condensation will cause  
deterioration of the relay insulation.  
5) Freezing  
3) Keep the ripple rate of the nominal coil  
voltage below 5%.  
4) The cycle lifetime is defined under the  
standard test condition specified in the  
JIS C 5442 standard (temperature 15 to  
35°C 59 to 95°F, humidity 25 to 75%).  
Check this with the real device as it is  
affected by coil driving circuit, load type,  
activation frequency, activation phase,  
ambient conditions and other factors.  
Also, be especially careful of loads such  
as those listed below.  
Condensation or other moisture may  
freeze on the relay when the  
temperatures is lower than 0°C 32°F. This  
causes problems such as sticking of  
movable parts or operational time lags.  
6) Low temperature, low humidity  
environments  
The plastic becomes brittle if the relay is  
exposed to a low temperature, low  
humidity environment for long periods of  
time.  
(1) When used for AC load-operating and  
the operating phase is synchronous.  
Rocking and fusing can easily occur due  
to contact shifting.  
(2) Highly frequent load-operating  
ASCTB92E 201206-T  
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Panasonic:  
ALQ105 ALQ106 ALQ109 ALQ112 ALQ118 ALQ124 ALQ305 ALQ306 ALQ309 ALQ312 ALQ318 ALQ324  

相关型号:

ALQ12F48-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ12F48N-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ12M48-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ12M48N-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ12Y48-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ12Y48N-L

Delivers up to 12 A output current (6.3 A for the 8 Vo)
EMERSON-NETWO

ALQ15-DUAL

60 Watts Dual Output Converter
ASTEC

ALQ15-DUAL

High Efficiency
EMERSON-NETWO

ALQ15AF48

Industry Standard  Brick: 36V-75V Input / 60W Output Power
ASTEC

ALQ15AF48

High Efficiency
EMERSON-NETWO

ALQ15AF48-6

60 Watts Dual Output Converter
ASTEC

ALQ15AF48-6

High Efficiency
EMERSON-NETWO