CN-71-C2 [PANASONIC]

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only;
CN-71-C2
型号: CN-71-C2
厂家: PANASONIC    PANASONIC
描述:

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only

文件: 总6页 (文件大小:618K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only  
157  
FX-301-F7 FX-301-F  
General terms and conditions............. F-3  
Glossary of terms / General precautions....P.1549~ / P.1552~  
Selection guide ……………………… P.3~  
Korea's S-mark............................. P.1602  
FIBER  
SENSORS  
Related Information  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
Recognition  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
Certified  
(FX-301-F only)  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
panasonic.net/id/pidsx/global  
PNP output  
Light intensity  
Timer  
Automatic  
type available monitor  
sensitivity setting  
STATIC  
CONTROL  
DEVICES  
LASER  
Easy operation even for beginners!  
Optimum settings can be realized with simple operations  
MARKERS  
PLC  
HUMAN MACHINE  
INTERFACES  
FX-301-F7  
For use with leak detection or liquid detection fiber only  
Sets the optimal threshold value  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Incident light  
intensity  
(During teaching)  
The FX-301-F7 (Note 1) dedicated for the leak detection fiber FD-F71  
and the FX-301-F dedicated for the liquid detection fiber FT-F93 are  
available. Optimal setting is possible with easy operation.  
Note: The FX-301-F can be also used by setting it to leak detection mode. However, the  
functions are different from the FX-301-F7 dedicated for the leak detection fiber,  
so it is recommended to use the FX-301-F7 when using the leak detection fiber.  
Threshold value will  
be set automatically to  
-20 % of the incident  
light intensity during  
the teaching to steadily  
detect the leak. It is also  
possible to change the  
threshold value to -15 %  
or -30 %.  
FA COMPONENTS  
-15 %  
-20 %  
-30 %  
(At the time of factory shipment)  
MACHINE VISION  
SYSTEMS  
Threshold value  
UV CURING  
SYSTEMS  
Leak detection fiber  
Liquid detection fiber  
FD-F71  
FT-F93  
Threshold follow-up function  
FX-301-F7  
Selection  
Guide  
Incident  
light  
Incident light intensity is  
checked at regular time  
interval (10 min.), and  
threshold value is reset  
automatically.  
Fibers  
intensity  
(Current value)  
Fiber  
Amplifiers  
Threshold  
value  
Other Products  
Dedicated amplifier for the  
leak detection fiber  
FX-301-F7  
Dedicated amplifier for the  
liquid detection fiber  
FX-301-F  
Time  
FX-300  
FX-311  
*Function is set to OFF at the time of factory shipment.  
Flashing function incorporated  
FX-301-F7/  
FX-301-F  
FX-11A  
When the leak detection fiber is connected (F7 mode), if  
a leak is detected, you will recognize which fiber detects  
the leak at a single glance because the emitter will start  
flashing.  
FX2  
FX-CH2  
FX-CH  
Easy maintenance, as main and sub units are identical  
Both main and sub units utilize the same amplifier body. This  
feature allows for easy mounting in the side-by-side configuration.  
Long life and stable operational settings due  
to the newly developed emitting element  
The main and sub unit  
Sub cable  
functions are distinguished  
only by the proper use of  
3-core main cable and the  
1-core sub cable.  
Moreover, by utilizing the same  
body for both main and sub  
units, inventory management  
and maintenance is simplified.  
The newly developed “four-chemical emitting element”  
used for FX-301-F7 / FX-301-F can suppress the  
secular change of the light emitting element to minimum,  
allowing stable detection for long period of time.  
Main cable  
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F  
158  
Easy to operate with individual / collective teaching mode  
FIBER  
SENSORS  
Individual teaching mode (TEACH)  
Collective teaching mode (ALL)  
LASER  
SENSORS  
Optimal threshold value is set automatically on  
FX-301-F7 just by setting the MODE indicator to “TEACH”  
and pressing the jog switch.  
Teaching is performed collectively for all the connected  
amplifiers with an optical communication function when  
the MODE indicator is set to “ALL”. Each amplifier will be  
set with an optimal threshold value.  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
The threshold value is set after selecting the liquid  
detection fiber for FX-301-F.  
At the same time, other setting in the master unit will  
be copied to the slave unit.  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Communication direction  
Collective teaching mode is possible for 16 units max.  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
LEAK DETECTION FIBER (FD-F71)  
STATIC  
CONTROL  
DEVICES  
Low profile liquid detection fiber with high chemical resistance  
LASER  
MARKERS  
Labor-saving design  
Because all you need to install is one screw, one-touch  
PLC  
mounting of the fiber head is possible.  
Replacement parts even for resetting after a leak are  
unnecessary.  
HUMAN MACHINE  
INTERFACES  
Because the fiber head is simply designed, wiping off  
leaks is rendered easy.  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Superb explosion resistance / chemical resistance  
FA COMPONENTS  
SEMI S2 compliant!  
Explosion resistance is enhanced by adopting the fiber  
method (SEMI S2 compliant). The head unit made  
of fluorocarbon polymers also has superb chemical  
resistance.  
MACHINE VISION  
SYSTEMS  
Leak detection fiber cannot be used in combination  
with the FX-100/300/311/410 series.  
UV CURING  
SYSTEMS  
Stable detection performance  
The unique effect of capillarity enables reliable detection  
of small leaks and viscous liquids.  
Amplifier Built-in Leak Detection Sensor  
High-speed detection  
even a little liquid leak  
Selection  
Guide  
Fibers  
FD-F71  
Fiber  
EX-F70 SERIES  
EX-F60 SERIES  
Amplifiers  
Other Products  
FX-300  
FX-311  
P.877  
FX-301-F7/  
FX-301-F  
FX-11A  
Capillarity effect  
Fiber head  
FX2  
FX-CH2  
FX-CH  
Liquid  
Leakage pan  
Compact, space-saving  
This slim (10 mm 0.394 in) side-mounting fiber head is  
especially good for use in confined spaces.  
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F  
159  
LIQUID DETECTION FIBER (PIPE-MOUNTABLE) (FT-F93)  
Stably detect the liquid inside the pipe!  
FIBER  
SENSORS  
LASER  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
Stable design that doesn’t permit liquid-absent or  
sensor errors  
MICRO  
PHOTO-  
When liquid is present, its effect on the lens causes  
light to focus and enter.  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
Liquid present  
Liquid absent  
SAFETY LIGHT  
CURTAINS  
/
SAFETY  
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
Beam-receiving signal  
Low  
Beam-receiving signal  
High  
INDUCTIVE  
PROXIMITY  
SENSORS  
SEMI S2 compliant!  
PARTICULAR  
USE  
When abnormalities such as a severed or removed  
fiber or a cutoff cable occur, light does not enter and the  
sensor will output the same as “liquid-absent”.  
Leak detection fiber cannot be used in combination  
with the FX-100/300/311/410 series.  
SENSORS  
SENSOR  
OPTIONS  
When the fiber cable is severed  
SIMPLE  
WIRE-SAVING  
UNITS  
Superior explosion resistance compatible to SEMI S2  
Because there is no electric circuitry in the fiber head, it  
boasts excellent explosion resistance.  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
Beam-receiving signal  
Easy to use and reliable detection  
Severed!  
Zero  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Even when the shape and thickness of the pipe vary, this  
fiber head uses a method where the beam axis follows  
the diameter of the pipe, and so when compared to  
conventional methods, the shape and thickness of the  
pipe have no influence over the performance of this fiber  
head.  
Reliable detection not affected by bubbles or droplets  
Latest optical fiber techniques have solved problems  
caused by bubbles, droplets or liquid leakage that arise  
in conventional pipe-mountable fiber heads.  
LASER  
MARKERS  
PLC  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
ORDER GUIDE  
FA  
COMPONENTS  
Amplifiers  
Quick-connection cable is not supplied with the amplifier. Please order it separately.  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
Type  
Appearance  
Model No.  
Emitting element  
Output  
SYSTEMS  
NPN output  
PNP output  
NPN output  
PNP output  
FX-301-F7  
NPN open-collector transistor  
Leak  
detection  
fiber only  
Red LED  
Selection  
Guide  
FX-301P-F7  
FX-301-F  
PNP open-collector transistor  
NPN open-collector transistor  
PNP open-collector transistor  
Fibers  
Fiber  
Amplifiers  
Other  
Products  
Liquid  
detection  
fiber only  
Red LED  
FX-301P-F  
FX-300  
FX-311  
FX-301-F7/  
FX-301-F  
Quick-connection cable is not supplied with the amplifier. Please order it separately.  
Quick-connection cables  
FX-11A  
FX2  
Main cable  
Type  
Model No.  
Description  
• CN-73-C□  
FX-CH2  
FX-CH  
Length: 1 m 3.281 ft  
CN-73-C1  
CN-73-C2  
CN-73-C5  
CN-71-C1  
CN-71-C2  
CN-71-C5  
0.2 mm2 3-core cabtyre cable, with  
Main cable  
(3-core)  
Length: 2 m 6.562 ft connector on one end  
Cable outer diameter: ø3.3 mm ø0.130 in  
Length: 5 m 16.404 ft  
Length: 1 m 3.281 ft  
Sub cable  
0.2 mm2 1-core cabtyre cable, with  
Sub cable  
(1-core)  
Length: 2 m 6.562 ft connector on one end  
Cable outer diameter: ø3.3 mm ø0.130 in  
• CN-71-C□  
Length: 5 m 16.404 ft  
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F  
160  
ORDER GUIDE  
FIBER  
SENSORS  
LASER  
End plates are not supplied with the amplifier. Please order it separately when the amplifiers are mounted in cascade.  
SENSORS  
End plates  
PHOTO-  
ELECTRIC  
SENSORS  
Appearance  
Model No.  
Description  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
When amplifiers are mounted in cascade, or when  
an amplifier moves depending on the way it is  
installed on a DIN rail, these end plates clamp  
amplifiers into place on both sides. Make sure to  
use end plates when cascading multiple amplifiers  
together.  
AREA  
SENSORS  
MS-DIN-E  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
2 pcs. per set  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
: Refers to a fiber which possesses both unbreakable (bending radius: R10 mm R0.394 in, reciprocating bending: 180°)  
and more flexible (bending radius: R4 mm R0.157 in or less) features.  
Fiber heads  
PARTICULAR  
USE  
: Refers to a fiber which possesses unbreakable bending-resistant feature (bending radius: R10 mm R0.394 in,  
reciprocating bending: 180°).  
Bending durability  
SENSORS  
SENSOR  
OPTIONS  
Bending Fiber cable length  
Shape of fiber head  
Ambient  
temp.  
radius  
(mm)  
:
Designation  
Model No.  
Description  
Protection  
Dimensions  
(mm in)  
SIMPLE  
Free-cut  
WIRE-SAVING  
UNITS  
SEMI S2 compliant  
Liquid leak detection  
−20 to  
+60 °C  
−4 to  
WIRE-SAVING  
SYSTEMS  
Bending durability  
W20 × H30 × D10  
Leak absent: Beam received,  
Leak present: Beam not received  
Dedicated amplifier for the leak detection fiber :  
FX-301-F7  
Leak  
detection  
fiber  
W0.787 × H1.181 × D0.394  
IP67  
P.68  
5 m  
16.405 ft  
R4  
FD-F71  
MEASURE-  
MENT  
+140 °F  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Applicable pipe diameter:  
Outer dia. ø3 to ø10 mm  
SEMI S2 compliant  
Bending durability  
W23 × H20 × D17  
ø0.118 to ø0.394 in Transparent pipe  
PFA (fluorine resin) or equivalently transparent pipe,  
wall thickness 0.3 to 1.0 mm 0.012 to 0.039 in  
Liquid absent: Beam not received,  
Liquid present: Beam received  
LASER  
Protective  
tube R20  
Fiber  
−40 to  
+60 °C  
−40 to  
MARKERS  
Liquid  
detection  
fiber  
W0.906 × H0.787 × D0.669  
IP40  
P.58  
FT-F93  
2 m  
6.562 ft  
PLC  
R2  
+140 °F  
HUMAN  
Dedicated amplifier for the liquid detection fiber :  
FX-301-F  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
About the handling of the fiber cable length changed product  
The type with fiber cable length changed is prepared as a semi-custom product with fast response.  
Please contact the sales regarding the model name, standard price, and delivery.  
Applicable fiber cable length: Up to 25 m 82.021 ft, in 1 m 3.281 ft intervals.  
FA  
COMPONENTS  
MACHINE  
VISION  
Applicable protective tube length: Up to 10 m 32.808 ft, in 0.5 m 1.641 ft intervals.  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Accessories  
FX-CT2 (Fiber cutter)  
FX-AT4 (Attachment for ø1 mm ø0.039 in fiber, black)  
MS-FD-F7-1 (SUS mounting bracket for FD-F71)  
MS-FD-F7-2 (PVC mounting bracket for FD-F71)  
Selection  
Guide  
Fibers  
• FX-CT2  
• FX-AT4  
• MS-FD-F7-1  
(SUS mounting bracket for FD-F71)  
• MS-FD-F7-2  
(PVC mounting bracket for FD-F71)  
Fiber  
Amplifiers  
Other  
Products  
FX-300  
FX-311  
OPTIONS  
FX-301-F7/  
FX-301-F  
FX-11A  
FX2  
Amplifier mounting bracket  
Designation  
Model No.  
Description  
• MS-DIN-2  
FX-CH2  
FX-CH  
Amplifier  
mounting bracket  
Mounting bracket for amplifier  
MS-DIN-2  
FX-MB1  
10 sets of 2 communication window seals and 1 connector seal  
Communication window seal:  
It prevents malfunction due to transmission signal from another  
amplifier, as well as, prevents effect on another amplifier.  
Connector seal:  
Fiber sensor  
amplifier  
protection seal  
Fiber sensor amplifier protection seal  
Communication  
window seal  
• FX-MB1  
It prevents contact of any metal, etc., with the pins of the quick-  
connection cable.  
Connector seal  
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F  
161  
FIBER  
DIMENSIONS (Unit: mm in)  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Amplifier  
FX-301(P)-F7 FX-301(P)-F  
PHOTO-  
ELECTRIC  
SENSORS  
48.2  
12  
1.898  
0.472  
MICRO  
PHOTO-  
26.3  
1.035  
ELECTRIC  
SENSORS  
0.7  
8.3  
2.5  
0.028  
0.327  
0.098  
AREA  
SENSORS  
Operation indicator (Orange)  
SAFETY LIGHT  
MODE key  
Jog switch  
FX-301(P)-F7:  
CURTAINS  
/
SAFETY  
Automatic follow-up function indicator  
FX-301(P)-F:  
Digital display (Red)  
COMPONENTS  
PRESSURE /  
FLOW  
Model indicator (Green) (Note 1)  
SENSORS  
3
3
INDUCTIVE  
PROXIMITY  
SENSORS  
64.5 2.539  
Communication  
window  
10  
0.118  
0.118  
27.8  
1.094  
0.394  
7
Beam-  
emitting  
part  
0.276  
PARTICULAR  
USE  
SENSORS  
30.5  
SENSOR  
OPTIONS  
1.201  
10.5  
7 0.276  
Beam-  
receiving  
part  
0.413  
7 0.276  
SIMPLE  
WIRE-SAVING  
UNITS  
3
3.95  
0.118 13.5  
0.531  
36.5  
0.156  
1.437  
Suitable for 35 mm 1.378 in width DIN rail  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
Note: Above figure is an external dimension drawing of the FX-301(P)-F7. Shape of the indicator for FX-301(P)-F is little different.  
STATIC  
CONTROL  
DEVICES  
LASER  
Main cable (Optional)  
Sub cable (Optional)  
CN-73-C□  
CN-71-C□  
MARKERS  
PLC  
L
L
HUMAN  
MACHINE  
INTERFACES  
ø3.3 ø0.130 cable  
10  
ø3.3 ø0.130 cable  
10  
0.394  
6
0.394  
6
ENERGY  
MANAGEMENT  
SOLUTIONS  
14  
14  
0.551  
0.236  
2.9  
0.236  
2.9  
0.551  
0.114  
0.114  
2.54  
2.54  
FA  
0.100  
0.100  
COMPONENTS  
10.5  
10.5  
MACHINE  
VISION  
0.413  
0.413  
SYSTEMS  
2.54  
7
2.54  
7
UV  
CURING  
0.100  
0.2  
0.008  
3
0.2  
0.008  
0.100  
0.276  
10  
0.276  
10  
3
2.65  
2.65  
0.118  
SYSTEMS  
0.118  
0.104  
0.104  
0.394  
7.2  
0.394  
7.2  
13.6  
0.283  
13.6  
0.283  
0.535  
0.535  
Length L  
Model No.  
CN-73-C1  
CN-73-C2  
CN-73-C5  
Length L  
Model No.  
CN-71-C1  
CN-71-C2  
CN-71-C5  
Selection  
Guide  
Length L  
Length L  
Fibers  
1,000 39.390  
2,000 78.740  
5,000 196.850  
1,000 39.390  
2,000 78.740  
5,000 196.850  
Fiber  
Amplifiers  
Other  
Products  
FX-300  
FX-311  
Amplifier mounting bracket (Optional)  
End plates (Optional)  
MS-DIN-2  
MS-DIN-E  
FX-301-F7/  
FX-301-F  
21.6  
2.75  
0.850  
0.108  
FX-11A  
FX2  
3.2  
16  
5.2  
0.126  
0.630  
0.205  
M3 (length 18 mm 0.709 in) pan head screws  
3
10  
8.5  
0.335  
0.394  
FX-CH2  
FX-CH  
60  
3
2.362  
0.118  
0.118  
15  
5.6 M3 square nut  
3.2  
5.2  
0.591  
0.220  
0.126  
5
0.205  
0.197  
35  
1.378  
0.4  
2
24.7  
0.016 0.079  
0.972  
ø1.8  
2
ø0.071 0.079  
7.5  
32  
4
1.6  
0.063  
4.2 0.165  
0.295  
t 1  
t 0.039  
1.260  
0.157  
Suitable for 35 mm 1.378 in width DIN rail  
27  
2-ø3.2 ø0.126 holes  
1.063  
Material: Cold rolled carbon steel (SPCC)  
(Uni-chrome plated)  
Material: Polycarbonate  
Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only FX-301-F7 FX-301-F  
162  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
FD-F71  
Free-cut  
FT-F93  
Free-cut  
PHOTO-  
<with FX-AT4>  
<with FX-AT4>  
ELECTRIC  
SENSORS  
Fiber  
20 0.787  
2,000 78.740  
1,000  
5,000 196.850  
3,000 118.110  
30 1.181  
Beam-emitting side  
(Gray)  
12  
MICRO  
2-ø1 ø0.039  
2-ø1  
ø0.039  
39.370  
Emission indicator  
PHOTO-  
ELECTRIC  
SENSORS  
0.472  
7.8 0.307  
Beam-emitting side  
(Gray)  
7.2 0.283  
10  
Beam-receiving side  
(Black)  
ø0.25 ø0.010 × 4 fiber core (PMMA)  
Sheath ø1 ø0.039 (Polyethylene)  
23  
0.906  
AREA  
Beam-receiving side  
(Black)  
ø0.25 ø0.010 fiber core × 4 (PMMA)  
Outer sheath ø1 ø0.039 (Polyethylene)  
0.394  
0.787  
20  
6 0.236  
10.3 0.406  
SENSORS  
Enclosure  
(ABS)  
5.5 0.217  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
[PFA(Fluorine resin)]  
ø3.1 ø0.122 Protective tube [PFA(Fluorine resin)]  
(ø3.1) (ø0.122) Protective tube  
[PFA(Fluorine resin)]  
6 0.236  
COMPONENTS  
ø3.1 ø0.122  
10  
0.394  
PRESSURE /  
FLOW  
17  
0.669  
9 0.354  
SENSORS  
22 0.866  
INDUCTIVE  
PROXIMITY  
SENSORS  
SUS mounting bracket  
(MS-FD-F7-1)  
PARTICULAR  
USE  
SUS mounting bracket  
mounting diagram  
SENSORS  
17  
0.669  
SENSOR  
OPTIONS  
6.2 0.244  
10  
0.394  
30 1.181  
10  
0.3  
0.012  
15  
0.591  
SIMPLE  
0.394  
12.2 0.480  
0.697  
17.7  
WIRE-SAVING  
UNITS  
5.5 0.217  
11 0.433  
FD-F71  
11.5  
0.453  
ø4.2 ø0.165 thru-holes  
Material: [PFA(Fluorine resin)]  
SUS mounting bracket  
WIRE-SAVING  
SYSTEMS  
Material: Stainless steel (SUS316)  
10.3 0.406  
0.3 0.012  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
PVC mounting bracket  
(MS-FD-F7-2)  
PVC mounting bracket  
mounting diagram  
LASER  
12  
0.472  
MARKERS  
30 1.181  
10  
25 0.394  
10  
0.394  
5.7  
0.224  
PLC  
0.984  
10.5 0.413  
15.5  
0.610  
FD-F71  
HUMAN  
4 0.157  
Welding part  
MACHINE  
INTERFACES  
11.5  
0.453  
PVC mounting bracket  
11  
0.433  
Material: PVC  
ENERGY  
10 0.394  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Selection  
Guide  
Fibers  
Fiber  
Amplifiers  
Other  
Products  
FX-300  
FX-311  
FX-301-F7/  
FX-301-F  
FX-11A  
FX2  
FX-CH2  
FX-CH  

相关型号:

CN-71-C5

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
PANASONIC

CN-73-C1

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
PANASONIC

CN-73-C2

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
PANASONIC

CN-73-C5

Digital Fiber Sensor for Leak Detection / Liquid Detection Fibers Only
PANASONIC

CN-A110

30W to 200W 60 to 160VDC Input DC-DC Converters
TDK

CN-A24

50 & 100W 14.4 to 36VDC Input DC-DC Converters
TDK

CN0001

Telecom and Datacom Connector, 8 Contact(s), Male, Plug
BEL

CN009P-018

Board Connector, 18 Contact(s), 2 Row(s), Male, Straight, Solder Terminal, Plug
YAMAICHI

CN01

Circuit Protection Solutions Low Voltage Fuse Links Catalogue
COOPER

CN015P-2001-0

PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI

CN015P-2001-1

PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI

CN015P-2103-0

PCMCIA Connector, 24 Contact(s), 1 Row(s), Female, Right Angle, Surface Mount Terminal, Socket
YAMAICHI