CY-192VB-P-Y [PANASONIC]

Cylindrical Photoelectric Sensor;
CY-192VB-P-Y
型号: CY-192VB-P-Y
厂家: PANASONIC    PANASONIC
描述:

Cylindrical Photoelectric Sensor

文件: 总6页 (文件大小:568K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Amplifier Built-in  
CCyliYndri-ca1l P0ho0toelSecEtrRicISEeSnsor  
273  
General terms and conditions............. F-3  
Related Information  
Selection guide ............................. P.231~  
General precautions ................... P.1552~  
FIBER  
SENSORS  
Glossary of terms ....................... P.1549~  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
Listing  
(2 m cable length type only)  
MICRO  
PHOTOELECTRIC  
SENSORS  
FEATURES  
AREA  
SENSORS  
• Wide product range  
Shape: Standard type  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
Side view type  
Connector: 2 m (6.562 ft) cable length type  
M12 plug-in connector type  
• Diffuse reflective type sensor with  
sensitivity adjuster is available.  
• M18 thread size for convenient mounting  
• Strong resistance IP67  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
panasonic.net/id/pidsx/global  
SIMPLE  
WIRE-SAVING  
UNITS  
• Convenient universal sensor mounting  
stand is available.  
WIRE-SAVING  
SYSTEMS  
ORDER GUIDE  
MEASUREMENT  
SENSORS  
2 m cable length type  
STATIC  
CONTROL  
DEVICES  
Model No. (Note 1)  
Output  
operation  
Type  
Appearance  
Sensing range  
15 m  
NPN output  
PNP output  
CY-111A-P  
LASER  
MARKERS  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
Light-ON  
Dark-ON  
CY-111A  
49.213 ft  
CY-111B  
CY-111B-P  
PLC  
CY-192A-Y  
CY-192B-Y  
CY-191A-Y  
CY-191B-Y  
CY-121A  
CY-192A-P-Y  
CY-192B-P-Y  
CY-191A-P-Y  
CY-191B-P-Y  
CY-121A-P  
4 m  
13.123 ft  
HUMAN MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
2 m  
6.562 ft  
FA COMPONENTS  
100 mm  
3.937 in  
CY-121B  
CY-121B-P  
MACHINE VISION  
SYSTEMS  
CY-122A  
CY-122A-P  
600 mm  
23.622 in  
UV CURING  
SYSTEMS  
CY-122B  
CY-122B-P  
CY-111VA  
CY-111VB  
CY-192VA-Y  
CY-192VB-Y  
CY-191VA-Y  
CY-191VB-Y  
CY-121VA  
CY-121VB  
CY-122VA  
CY-122VB  
CY-111VA-P  
CY-111VB-P  
CY-192VA-P-Y  
CY-192VB-P-Y  
CY-191VA-P-Y  
CY-191VB-P-Y  
CY-121VA-P  
CY-121VB-P  
CY-122VA-P  
CY-122VB-P  
15 m  
49.213 ft  
4 m  
13.123 ft  
Selection  
Guide  
Amplifier  
Built-in  
2 m  
6.562 ft  
Power Supply  
Built-in  
Amplifier-  
separated  
100 mm  
3.937 in  
600 mm  
23.622 in  
EX-Z  
CX-400  
CY-100  
EX-10  
Notes: 1) The model No. with “E” shown on the label affixed to the thru-beam type sensor is the emitter, “D” shown on the label is the receiver. (e.g.)  
2) The reflector is sold separately.  
3) The sensing range of the retroreflective type sensor is specified for the RF-420 reflector (optional).  
EX-20  
EX-30  
• Standard type  
• Side view type  
M12 plug-in connector type  
EX-40  
M12 plug-in connector type is also available.  
When ordering this type, suffix “-Z” for the M12 plug-in connector type to the  
model No. (e.g.) M12 plug-in connector type of CY-111A-P is “CY-111A-P-Z”.  
In case of the retroreflective type, M12 plug-in connector type of  
CY-19□-P-Y is “CY-19□-P-Z-Y”.  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
RT-610  
Cylindrical Photoelectric Sensor CY-100 SERIES  
274  
ORDER GUIDE  
FIBER  
SENSORS  
LASER  
(2 cables are required for the thru-beam type.)  
Mating cable  
Mating cable  
SENSORS  
PHOTO-  
• Straight type  
• Elbow type  
Type  
Model No.  
Description  
ELECTRIC  
SENSORS  
MICRO  
Length: 2 m 6.562 ft  
CN-24C-C2  
CN-24C-C5  
CN-24CL-C2  
CN-24CL-C5  
PHOTO-  
ELECTRIC  
SENSORS  
Clamping ring :  
ø14mm 0.551 in  
Straight  
Length: 5 m 16.404 ft  
Length: 2 m 6.562 ft  
Length: 5 m 16.404 ft  
AREA  
Cable outer :  
ø5.3mm 0.209 in  
SENSORS  
Elbow  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
OPTIONS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
Sensor mounting bracket  
Designation  
Model No.  
Description  
SENSORS  
• MS-CY1-1  
• MS-CY1-2  
SENSOR  
OPTIONS  
Material: Stainless steel  
MS-CY1-1  
MS-CY1-2  
Sensor mounting  
bracket  
Material: Plastic, For beam axis alignment  
SIMPLE  
WIRE-SAVING  
UNITS  
It can adjust the height of the sensor and  
reflector RF-420.  
(The thru-beam type sensor needs two  
brackets.)  
Universal sensor  
mounting stand  
MS-AJ3  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
50 × 50 mm 1.969 × 1.969 in  
24 × 21 mm 0.945 × 0.827 in  
RF-420  
RF-410  
SENSORS  
Reflector  
STATIC  
CONTROL  
DEVICES  
22 mm × 5 m 0.866 × 196.850 in,  
Thickness: 0.4 mm 0.016 in  
Reflective tape  
RF-40RL5  
LASER  
MARKERS  
Universal sensor  
mounting stand  
Reflector  
Reflective tape  
PLC  
• RF-420  
• RF-410  
HUMAN  
• RF-40RL5  
MACHINE  
INTERFACES  
• MS-AJ3  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
WIRING DIAGRAMS  
Selection  
Guide  
Wiring diagram  
Amplifier  
Built-in  
Power Supply  
Emitter of thru-beam type  
Receiver of thru-beam / Reflective type  
Built-in  
Amplifier-  
separated  
NPN output type  
ꢃ%URZQꢄꢅꢆ9  
(Brown) +V  
1
Load  
EX-Z  
4
±
+
(Black) Output  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
ꢀꢁꢅWRꢅꢁꢇꢅ9ꢅ'&ꢅ“ꢀꢈꢅ  
12 to 24 V DC ±10  
ꢃ9LROHWꢄꢅ,QSXW  
3
(Blue) 0 V  
ꢃ%OXHꢄꢅꢈꢅ9  
Connector pin position  
Receiver of thru-beam / Reflective type  
M12 connector  
PNP output type  
ꢀ%URZQꢁꢂꢆ9  
1 : +V  
4
3
2 : Input (Only emitter of thru-beam type)  
3 : 0 V  
4 : Output (Only receiver of thru-beam type and reflective type)  
1
2
ꢃꢈꢂWRꢂꢈꢄꢂ9ꢂ'&ꢂ“ꢃꢇꢂ  
ꢀ%ODFNꢁꢂ2XWSXW  
±
/RDG  
ꢀ%OXHꢁꢂꢇꢂ9  
RT-610  
Cylindrical Photoelectric Sensor CY-100SERIES  
275  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
Thru-beam  
Type  
Retroreflective  
With polarizing filters  
Diffuse reflective  
PHOTO-  
ELECTRIC  
SENSORS  
With sensitivity adjuster  
MICRO  
PHOTO-  
Standard Side view Standard Side view Standard Side view Standard Side view Standard Side view  
CY-111A□ CY-111VA□ CY-192A□ CY-192VA□ CY-191A□ CY-191VA□ CY-121A□ CY-121VA□ CY-122A□ CY-122VA□  
CY-111B□ CY-111VB□ CY-192B□ CY-192VB□ CY-191B□ CY-191VB□ CY-121B□ CY-121VB□ CY-122B□ CY-122VB□  
EMC Directive, RoHS Directive  
ELECTRIC  
SENSORS  
Light-ON  
Dark-ON  
AREA  
Item  
SENSORS  
CE marking directive compliance  
SAFETY LIGHT  
CURTAINS  
/
SAFETY  
100 mm 3.937 in  
(Note 3)  
600 mm 23.622 in  
(Note 3)  
COMPONENTS  
Sensing range  
15 m 49.213 ft  
4 m 13.123 ft (Note 2)  
2 m 6.562 ft (Note 2)  
PRESSURE /  
FLOW  
SENSORS  
ø18 mm ø0.709 in or  
more opaque object  
ø50 mm ø1.969 in or  
more opaque,  
translucent or  
ø50 mm ø1.969 in or  
more opaque, translu-  
INDUCTIVE  
PROXIMITY  
SENSORS  
Opaque, translucent or transparent object  
(Note 4)  
(
cent,  
or  
Sensing object  
Setting distance  
transparent  
object  
specular object  
between emitter and  
transparent  
)
(Note 2, 4)  
(Note 2, 4)  
PARTICULAR  
USE  
receiver: 15 m 49.213ft  
SENSORS  
Hysteresis  
3 to 15 % of operation distance (Note 3)  
SENSOR  
OPTIONS  
Supply voltage  
12 to 24 V DC ±10 % Ripple P-P 10 % or less  
35 mA or less  
Emitter: 35 mA or less  
Receiver: 35 mA or less  
SIMPLE  
WIRE-SAVING  
UNITS  
Current consumption  
Output  
<NPN output type>  
NPN open-collector transistor  
<PNP output type>  
PNP open-collector transistor  
WIRE-SAVING  
SYSTEMS  
• Maximum sink current: 100 mA  
• Maximum source current: 100 mA  
MEASURE-  
MENT  
• Applied voltage: 24 V DC or less (between output and 0 V)  
• Residual voltage: 1.5 V or less  
• Applied voltage: 24 V DC or less (between output and +V)  
• Residual voltage: 1.5 V or less  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Utilization category  
Short-circuit protection  
Response time  
DC-12 or DC-13  
Incorporated  
1 ms or less  
LASER  
MARKERS  
PLC  
Test input (emission halt) function  
Operation indicator  
Incorporated  
Yellow LED (lights up when the output is ON) (incorporated on the receiver for thru-beam type)  
Green LED (lights up  
when the power is ON)  
(incorporated on the  
emitter)  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Power indicator  
FA  
COMPONENTS  
Pollution degree  
Protection  
3 (Industrial environment)  
IP67 (IEC)  
MACHINE  
VISION  
SYSTEMS  
Ambient temperature  
Ambient humidity  
Ambient illuminance  
Voltage withstandability  
Vibration resistance  
Shock resistance  
Emitting element  
Peak emission wavelength  
Material  
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –40 to +70 °C –22 to +158 °F  
50 % RH (at +70 °C +158 °F)  
UV  
CURING  
SYSTEMS  
Incandescent light: 5,000 ℓx or less at the light-receiving face  
500 V AC for one min. between all supply terminals connected together and enclosure  
10 to 55 Hz frequency, 0.5 mm 0.020 in double amplitude in X, Y and Z directions for 1.5 hours each  
294 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each  
Selection  
Guide  
Amplifier  
Built-in  
Infrared LED (modulated)  
890 nm 0.035 mil 875 nm 0.034 mil  
Red LED (modulated)  
665 nm 0.026 mil  
Infrared LED (modulated)  
875 nm 0.034 mil  
Power Supply  
Built-in  
Amplifier-  
separated  
Enclosure: PBT, Lens: PMMA  
Cable (except for M12 plug-in  
connection type)  
0.44 mm2 3-core cabtyre cable, 2 m 6.562 ft long  
Extension up to total 10 m 32.808 ft is possible with 0.34 mm2, or more, cable (thru-beam type: both emitter and receiver).  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
Cable extension  
Emitter/  
Emitter/  
65 g  
approx.  
70 g  
approx.  
65 g  
approx.  
70 g  
approx.  
65 g  
approx.  
70 g  
approx.  
75 g  
approx.  
Receiver: 65 g Receiver: 70 g  
approx.  
2 m cable length type  
approx.  
Net weight  
(Note 5)  
Emitter/  
Emitter/  
15 g  
approx.  
20 g  
approx.  
15 g  
approx.  
20 g  
approx.  
15 g  
approx.  
20 g  
approx.  
25 g  
approx.  
Receiver: 15 g Receiver: 20 g  
approx. approx.  
M12 plug-in connector type  
Accessories  
Nut: 4 pcs.  
Nut: 2 pcs.  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.  
2) The sensing range and the sensing object of the retroreflective type sensor are specified for the RF-420 reflector (optional).  
3) The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 × 200 mm 7.874 × 7.874 in) as  
the object.  
4) Make sure to confirm detection with an actual sensor before use for detection of the transparent object and the translucent object.  
5) The weight includes the weight of nuts.  
RT-610  
Cylindrical Photoelectric Sensor CY-100 SERIES  
276  
DETECTION CURVES  
FIBER  
SENSORS  
LASER  
SENSORS  
Diffuse reflective type with  
adjustable sensitivity  
Retroreflective type with  
polarizing filters  
Thru-beam type  
Diffuse reflective  
Retroreflective type  
PHOTO-  
ø of beam  
ELECTRIC  
SENSORS  
in cm  
in cm  
3.937 10  
in  
cm  
cm  
1.4  
1
cm  
in  
0.551  
0.394  
in  
0.551 1.4  
0.394  
2.362  
1.575  
0.787  
6
4
2
MICRO  
ø 0.472 in  
PHOTO-  
ELECTRIC  
SENSORS  
in  
31.496  
80  
in  
5.906  
15  
5.906 15  
1
ø 12 mm  
1.575  
4
E/R  
m
cm  
cm  
1.969  
5
4
m
2
m
3
10 15  
0.2  
AREA  
-1.575 -4  
-3.937 -10  
-0.787 -2  
-1.575 -4  
-2.362 -6  
2
13.123 ft  
0.656 ft 6.562 ft 9.843 ft  
32.808 ft 49.213 ft  
SENSORS  
-5.906 -15  
-0.394 -1  
-0.551 -1.4  
-0.394 -1  
-0.551 -1.4  
6.562 ft  
49.213 ft  
23.622 in  
60 cm  
3.937 in  
10 cm  
6.562 ft  
13.123 ft  
4 m  
SAFETY LIGHT  
15 m  
A
A
A
2 m  
A
A
CURTAINS  
SAFETY  
/
COMPONENTS  
Object 10 × 10 cm; 1 White 90%; 2 Grey 18%  
With reflector RF-420  
With reflector RF-420  
A=Sensing range  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PRECAUTIONS FOR PROPER USE  
Refer to p.1552~ for general precautions.  
PARTICULAR  
USE  
SENSORS  
Wiring  
SENSOR  
OPTIONS  
• Never use this product as a sensing device  
for personnel protection.  
• In case of using sensing devices for  
personnel protection, use products which  
meet laws and standards, such as OSHA,  
ANSI or IEC etc., for personnel protection  
applicable in each region or country.  
• Make sure that the power supply is off while wiring.  
• Verify that the supply voltage variation is within the rating.  
• If power is supplied from a commercial switching regulator,  
ensure that the frame ground (F.G.) terminal of the power  
supply is connected to an actual ground.  
• Ensure that an isolation transformer is utilized for the DC  
power supply. If an autotransformer is utilized, the main  
body or power supply may be damaged.  
• If the used power supply generates a surge, connect a  
surge absorber to the power supply to absorb the surge.  
• Do not use during the initial transient time (0.5 sec) after  
the power supply is switched on.  
• In case noise generating equipment (switching regulator,  
inverter motor, etc.) is used in the vicinity of this product,  
connect the frame ground (F.G.) terminal of the equipment  
to an actual ground.  
• Do not run the wires together with high-voltage lines or  
power lines or put them in the same raceway. This can  
cause malfunction due to induction.  
• Damage or burnout may result in case of short circuit of  
load or miswiring.  
• Make a cable length as short as possible to lessen noise  
pickup.  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Mounting  
LASER  
• The tightening torque should be 3 N·m or less.  
• Use a cable with connector CN-24C(L)-C□ (optional) for  
M12 connector type.  
MARKERS  
PLC  
Tightening torque for connector part is 2 N·m or less.  
HUMAN  
MACHINE  
INTERFACES  
%RG\  
0RXQWLQJꢀSODWH  
&DEOHꢀZLWKꢀFRQQHFWRU  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
1XW  
1XW  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Mounting drawing with sensor or reflector RF-420  
Others  
• This device has been developed / produced for industrial  
use only.  
• Take care that the sensor is not directly exposed to  
fluorescent lamp from a rapid-starter lamp or a high  
frequency lighting device, as it may affect the sensing  
performance.  
• Avoid using a product where there is excessive vapor, dust  
or corrosive gas, or in a place where it could be exposed  
directly to water or chemicals.  
Selection  
Guide  
Amplifier  
Built-in  
Power Supply  
Built-in  
Amplifier-  
separated  
EX-Z  
• Take care that the sensor does not come in direct contact  
with water, oil, grease or organic solvents, such as,  
thinner, etc.  
• Do not use in an environment containing infammable or  
explosive gases.  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
• Never disassemble or modify the product.  
RT-610  
Cylindrical Photoelectric Sensor CY-100SERIES  
277  
FIBER  
DIMENSIONS (Unit: mm in)  
SENSORS  
LASER  
SENSORS  
Sensor  
CY-1□  
PHOTO-  
ELECTRIC  
SENSORS  
M18  
2 m cable length type (mm in)  
M12 plug-in connector type (mm in)  
MICRO  
PHOTO-  
a
b
a
b
ELECTRIC  
SENSORS  
Standard type CY-111□/121□/192□  
Standard type CY-191□  
46 1.811  
48 1.890  
62 2.441  
62 2.441  
78 3.071  
28 1.102  
28 1.102  
28 1.102  
44 1.732  
44 1.732  
60 2.362  
62 2.441  
76 2.992  
76 2.992  
92 3.622  
28 1.102  
28 1.102  
28 1.102  
44 1.732  
44 1.732  
b
a
AREA  
SENSORS  
SAFETY LIGHT  
Side view type CY-111V□/121V□/191V□/192V□  
Standard type CY-122□  
CURTAINS  
/
SAFETY  
COMPONENTS  
PRESSURE /  
FLOW  
Side view type CY-122V□  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
CN-24C-C2 CN-24C-C5  
Mating cable  
CN-24CL-C2 CN-24CL-C5  
Mating cable  
SENSORS  
¡ꢃꢆ  
27  
SENSOR  
OPTIONS  
1.063  
¡ꢀꢁꢂꢂꢃ 0ꢃꢉꢊ  
îꢃ  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
Connector pin position  
Connector pin position  
M12 × 1  
MEASURE-  
MENT  
BU  
BU  
BK  
4
BK  
4
SENSORS  
3
3
STATIC  
CONTROL  
DEVICES  
2
1
2
1
LASER  
MARKERS  
WH  
BN  
WH  
BN  
ø10  
PLC  
ø0.394  
L = 2 or 5 m  
6.562 or 16.404 ft  
L = 2 or 5 m  
6.562 or 16.404 ft  
¡ꢃꢀ  
¡ꢀꢁꢄꢅꢆ  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
MS-CY1-1  
Sensing mounting bracket  
MS-CY1-2  
Sensing mounting bracket  
FA  
COMPONENTS  
10  
0.394  
45  
ø18.2  
ø0.717  
2.5  
0.098  
50  
ø18.2  
ø0.717  
1.969  
1.772  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
28  
1.102  
=
=
55 2.165  
24  
15  
0.591  
8
8
1
0.315 0.945 0.315  
0.039  
Selection  
Guide  
=
=
Amplifier  
Built-in  
Power Supply  
Built-in  
Amplifier-  
6.5  
0.256  
20  
0.787  
separated  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
MS-AJ3  
Universal sensor mounting stand  
1. Ball-joint mounted fixing bracket CY-100 series or RF-420  
2. M12 rod  
3. Support for M12 rod  
36  
22.9  
0.902  
1.417  
ø18.5  
ø0.728  
5.7  
0.224  
40  
1.575  
M4  
ø6.5  
ø0.256  
53  
2.087  
19  
0.748  
M12  
76.5  
3.012  
RT-610  
Cylindrical Photoelectric Sensor CY-100 SERIES  
278  
DIMENSIONS (Unit: mm in)  
FIBER  
SENSORS  
LASER  
SENSORS  
RF-420  
Reflector  
RF-410  
Reflector  
PHOTO-  
4 - R5  
R0.197  
9
1.378  
35  
ELECTRIC  
SENSORS  
ø7.5  
ø0.295  
0.354  
2 - ø5.5  
ø0.217  
2 - ø4.5  
ø0.177  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
ø4.5  
ø0.177  
4
INDUCTIVE  
PROXIMITY  
SENSORS  
24 0.945  
0.157  
=
=
ø4.5  
ø0.177  
3.5  
0.138  
8
7.5  
0.295  
PARTICULAR  
USE  
29  
1.142  
0.315  
51.5  
2.028  
8
SENSORS  
0.315  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
PLC  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Selection  
Guide  
Amplifier  
Built-in  
Power Supply  
Built-in  
Amplifier-  
separated  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
RT-610  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY