DP-001 [PANASONIC]
Digital Pressure Sensor;型号: | DP-001 |
厂家: | PANASONIC |
描述: | Digital Pressure Sensor |
文件: | 总10页 (文件大小:800K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For Gas
Digital Pressure Sensor
703
DP-0 SERIES
■General terms and conditions............. F-3
■Glossary of terms........................ P.1563~
■Selection guide............................. P.699~
■General precautions ..................... P.1566
FIBER
SENSORS
Related Information
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
Digital
STATIC
CONTROL
DEVICES
LASER
MARKERS
Simple and easy operation
Redesigned for improvement of pressure sensor usability from ground up
PLC
HUMAN MACHINE
INTERFACES
Simple & easy operation
ENERGY
MANAGEMENT
SOLUTIONS
Two levels of configuration for easy operation of essential functions
The “RUN mode” is for setting the threshold value, the zero point adjustment and key lock/release setting, and the
“detailed configuration” allows the basic settings of sensor operation. The two-level configuration enables an easy
and immediate use of the product.
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Main menu for detailed configuration
Detailed configuration
Pressure unit
setting mode
Operation setting mode*
NO/NC setting mode
Operation
setting mode
Selection
Guide
RUN mode
Pressure/
Select from EASY mode,
hysteresis mode or window
comparator mode.
Set the comparative output
operation to NO or NC.
Digital Display
NO/NC
Pressure/
Head-separated
setting mode
Flow
Response time
setting mode
• Threshold value setting
• Zero point adjustment
• Key lock setting / release
Response time setting mode
Display color setting mode
Display color
setting mode
DP-0
DP-100
DP-M
Settings
initializing mode
Select the response time from
2.5 ms, 25 ms or 250 ms.
Select the comparative output ON/
OFF display color and the normal
display color from red or white.
* Refer to p.705 for details of operation setting mode.
Functional design
Black body for enhanced visibility of LCD display
The unit body is completely black to make the LCD
display easier to see.
Crisp
clicking feel
Firm and crisp clicking feel
The buttons offer firm and crisp clicking feel for smooth
and reliable setting operations.
Digital Pressure Sensor DP-0SERIES
704
APPLICATIONS
FIBER
SENSORS
LASER
SENSORS
Suction confirmation for electronic parts
Reference pressure check
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
High-quality LCD display
SENSOR
OPTIONS
Simple and highly visible display
Selection of display color from red or white
SIMPLE
WIRE-SAVING
UNITS
The LCD offers a wide viewing angle so the display
is easy to see even from an oblique angle. The
alphanumeric display (12-segment display), the key lock
The display color can be selected from red or white
in accordance with the output operation. Since the
detailed setting mode display is pink (unchangeable),
WIRE-SAVING
SYSTEMS
mark and the OVER mark are also clear and easy to see. the pressure sensor status can be easily recognized by
MEASUREMENT
SENSORS
color.
Pressure/setting display
STATIC
CONTROL
DEVICES
Mode
RUN mode
Comparative output
ON/OFF display
Detailed mode
Pink
Display
color setting
Comparative output ON Comparative output OFF
LASER
MARKERS
Red for ON, white for OFF
White for ON, red for OFF
Red in normal status
White in normal status
Red
White
Red
Key lock icon
OVER mark
PLC
White
Red
HUMAN MACHINE
INTERFACES
White
ENERGY
MANAGEMENT
SOLUTIONS
Pressure unit display
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg
High pressure type: MPa, kgf/cm2, bar, psi
RUN mode
Detailed setting mode
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Compact & light weight design
Extra-short depth and light weight
The unit body measures only 24.9 mm 0.980 in in depth
to allow installation in a shallow space. The main unit
weighs only about 25 g. The lightweight unit means
minimal load when mounted on a moving part such as a
robot arm.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Conventional model
(DP-100 series standard pressure port type)
DP-0 series
Flow
Approx.
DP-0
< Actual size >
Approx. 40 g
DP-100
DP-M
Depth
25 g
Comparison with
:
:
Approx.
Approx.
% shorter!
% lighter!
41
38
dimension
conventional model
Main unit
weight
DP-100 series standard
(
)
pressure port type
24.9 mm
0.980 in
42.5 mm 1.673 in
Low pressure type and high pressure type available
Two types to choose from depending on your application
<Low pressure type>
Ideal for applications such
as suction. No mis-operations
occur due to vacuum
breakdown.
The low pressure type can be used with positive or
negative pressure, while the high pressure type is
suitable for positive pressure of up to 1 MPa.
<High pressure type>
Ideal for applications such
as checking reference
pressure. Can also be
used for simple suction.
−100 kPa
0 kPa
100 kPa
Low
DP-001□
pressure type
1 MPa
High
pressure type
DP-002□
Digital Pressure Sensor DP-0SERIES
705
Three output modes
FIBER
SENSORS
Equipped with three output modes for use in a wide range of applications
LASER
SENSORS
(1) EASY mode
This mode is used for comparative output ON/
OFF control.
(2) Hysteresis mode
(3) Window comparator mode
PHOTOELECTRIC
SENSORS
This mode is used for setting comparative
output hysteresis to the desired level and for
carrying out ON/OFF control.
This mode is used for setting comparative
output ON and OFF at pressures within the
setting range.
MICRO
PHOTOELECTRIC
SENSORS
H (Hysteresis)
H (Hysteresis)
P-1
P-2
P-2
AREA
H (Hysteresis)
H (Hysteresis)
SENSORS
P-1
0
ON
OFF
P-1
0
ON
OFF
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
0
ON
OFF
Comparative
output
Comparative
output
Comparative
output
*H: 4 digits (fixed) (10 digits or more when using psi unit)
*H: 2 digits or more (5 digits or more when using psi unit)
*H: 4 digits or more (10 digits or more when using psi unit)
INDUCTIVE
PROXIMITY
SENSORS
Designed for easy installation
Panel mounting bracket
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
Tight installation is possible
Panel mounting bracket
MS-DP1-8
An exclusive mounting bracket
that is suitable for 1 to 3 mm 0.039
to 0.118 in panel thickness is
available.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Front protection cover
MS-DP1-3
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Neat and
space saving
PLC
T
ight installation is possible
HUMAN MACHINE
INTERFACES
A single
mounting hole
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
Exclusive mounting bracket
Connection cable
MACHINE VISION
SYSTEMS
Supports tight installation
Cable can be connected with one-touch
Space savings can also be
Connector attached cable (2 m 6.562 ft), as an
accessory, can be connected easily with one-touch
connection.
UV CURING
SYSTEMS
T
ight installation is possible
achieved even when an
L-shaped mounting
bracket is used.
Selection
Guide
Pressure/
Digital Display
Connection cable *
Pressure/
Head-separated
Positioning bosses for easier
mounting bracket installation
Flow
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
DP-0
DP-100
DP-M
MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
Types without connector attached cable are
(Accessory for MS-DP1-1)
also available
DP-00□-J
Commercially-available connectors can be used for cable
connections. Cables in required length can be used, so this
contributes to reduction in waste of unwanted cables.
Ceiling mounting
Floor mounting
MS-DP1-5
Environmentally
M3 (length 6 mm 0.236 in)
screws with washers
Commercially-available
friendly
(Accessory for MS-DP1-5)
parts can be used!
Rear mounting
* Refer to p.706 for recommended commercially-available connectors.
Digital Pressure Sensor DP-0SERIES
706
ORDER GUIDE
FIBER
SENSORS
LASER
Model No.
SENSORS
DP-00 1 - P - J
PHOTO-
ELECTRIC
SENSORS
MICRO
Rated pressure range
Cable
None : Connector attached cable 2 m 6.562 ft
: Type without connector attached cable
PHOTO-
ELECTRIC
SENSORS
1 : −100.0 to +100.0 kPa (Low pressure type)
2 : 0.000 to +1.000 MPa (High pressure type)
AREA
J
SENSORS
SAFETY LIGHT
CURTAINS
SAFETY
/
Comparative output
COMPONENTS
None : NPN output type
PRESSURE /
FLOW
SENSORS
P
: PNP output type
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
Type
Appearance
Rated pressure range
Model No.
Pressure port
Comparative output
SENSORS
SENSOR
OPTIONS
NPN open-collector transistor
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
DP-001
Low pressure
type
−100.0 to +100.0 kPa
0.000 to +1.000 MPa
SIMPLE
DP-001-P
DP-002
WIRE-SAVING
UNITS
M5 female thread
*CN-14A-C2
(Connector attached cable
2 m 6.562 ft ) is attached.
High pressure
type
WIRE-SAVING
SYSTEMS
DP-002-P
MEASURE-
MENT
SENSORS
Type without connector attached cable
Accessory
STATIC
CONTROL
DEVICES
Type without connector attached cable CN-14A-C2 is available. When ordering
this type, suffix “-J” to the Model No.
• CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
•
(e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J”
LASER
MARKERS
PLC
HUMAN
OPTIONS
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Recommended connector
Designation
Model No.
CN-14A-C1
Description
Contact: SPHD-001T-P0.5,
Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 2 m 6.562 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
FA
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
COMPONENTS
CN-14A-C2 (Note)
CN-14A-C3
Connector
attached cable
MACHINE
VISION
SYSTEMS
CN-14A-C5
Recommended crimping tool
UV
CURING
SYSTEMS
0.2 mm2 4-core bending-resistant
cabtyre cable with connector on
one end
Cable outer diameter: ø3.7 mm
ø0.146 in
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-14A
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Connector
attached cable
Bending-resistant
(
)
cable
Recommended connector (e-CON)
Selection
Guide
Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Connector
Set of 10 housings and 40 contacts
Pressure/
Allows sensors to be installed on the flooring or ceiling.
Digital Display
MS-DP1-1
MS-DP1-5
MS-DP1-8
MS-DP1-3
MS-DP1-7
Multiple sensors can also be mounted closely.
Sensor mounting
bracket
Pressure/
Note: Contact the manufacturer for details
of the recommended products.
Head-separated
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Flow
Panel mounting
bracket
Allows installation to panels with thickness of 1 to 3 mm 0.039
to 0.118 in. Multiple sensors can also be mounted closely.
DP-0
Front protection
cover
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
DP-100
DP-M
Conversion
bushing
Pressure port can be converted to Rc1/8 female thread.
Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series.
Digital Pressure Sensor DP-0SERIES
707
FIBER
SPECIFICATIONS
SENSORS
LASER
SENSORS
Type
Low pressure
DP-001
High pressure
DP-002
PHOTO-
ELECTRIC
SENSORS
NPN output
Item
PNP output
CE marking directive compliance
Type of pressure
DP-001-P
DP-002-P
MICRO
PHOTO-
ELECTRIC
SENSORS
EMC Directive, RoHS Directive
Gauge pressure
AREA
SENSORS
Rated pressure range
−100.0 to +100.0 kPa
0.000 to +1.000 MPa
SAFETY LIGHT
CURTAINS
/
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to + 1.010 bar
−14.65 to +14.65 psi
−756 to +756 mmHg
SAFETY
−0.010 to +1.010 MPa
−0.1 to +10.30 kgf/cm2
−0.1 to + 10.10 bar
−0.1 to +146.5 psi
COMPONENTS
PRESSURE /
FLOW
Set pressure range
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Pressure withstandability
Applicable fluid
500 kPa
1.5 MPa
PARTICULAR
USE
Air, non-corrosive gas
SENSORS
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg High pressure type: MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Selectable unit
SENSOR
OPTIONS
Supply voltage
SIMPLE
WIRE-SAVING
UNITS
Power consumption
30 mA or less
<NPN output type>
<PNP output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and 0 V)
• Residual voltage: 2 V or less (at 50 mA sink current)
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and +V)
• Residual voltage: 2 V or less (at 50 mA source current)
WIRE-SAVING
SYSTEMS
Comparative output
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
Output operation
Hysteresis
Selectable either NO or NC by key operation
Minimum 2 digits (variable)
LASER
MARKERS
Repeatability
±0.2 % F.S. (within ±4 digits)
±0.4 % F.S. (within ±4 digits)
Response time
Short-circuit protection
Display
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
PLC
HUMAN
MACHINE
INTERFACES
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
ENERGY
MANAGEMENT
SOLUTIONS
−101.0 to +101.0 kPa
−0.010 to +1.010 MPa
−1.030 to +1.030 kgf/cm2
−0.1 to +10.30 kgf/cm2
−1.010 to + 1.010 bar
−0.1 to + 10.10 bar
Displayable
pressure range
FA
−14.65 to +14.65 psi
−0.1 to +146.5 psi
COMPONENTS
−756 to +756 mmHg
MACHINE
VISION
Protection
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
IP40 (IEC)
SYSTEMS
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: -10 to +60 °C +14 to +140 °F
UV
CURING
SYSTEMS
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
Selection
Guide
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Pressure/
Digital Display
Pollution degree
2
Pressure/
Head-separated
Overvoltage category
Usable altitude
I
Flow
2,000 m 6,562 ft or less
Temperature characteristics
(+20 °C +68 °F standard)
+10 to +40 °C +50 to +104 °F: Within ±1 % F.S.
0 to +50 °C +32 to +122 °F: Within ±2.5 % F.S.
+10 to +40 °C +50 to +104 °F: Within ±2 % F.S.
0 to +50 °C +32 to +122 °F: Within ±5 % F.S.
DP-0
DP-100
DP-M
Grounding method
Pressure port
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated)
Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate
Material
Weight
25 g approx.
Accessory
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
Digital Pressure Sensor DP-0SERIES
708
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
NPN output type
SENSORS
PHOTO-
I/O circuit diagram
Terminal arrangement diagram
ELECTRIC
SENSORS
Terminal No.
MICRO
PHOTO-
ELECTRIC
SENSORS
Color code of connector attached cable
(Brown) +V
1
AREA
D1
SENSORS
SAFETY LIGHT
3
2
(White) Not connected (Note) Load
CURTAINS
SAFETY
/
+
1
2
3
4
12 to 24 V DC
±10 %
COMPONENTS
D2
(Black) Comparative output
50 mA MAX.
−
PRESSURE /
FLOW
Tr
SENSORS
ZD
Terminal
No.
Designation
(Blue) 0 V
INDUCTIVE
PROXIMITY
SENSORS
4
Internal circuit
Users’ circuit
+V
PARTICULAR
USE
Note: Open or, connect to 0 V.
SENSORS
Comparative output
Not connected (Note)
0V
SENSOR
OPTIONS
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
SIMPLE
WIRE-SAVING
UNITS
Tr: NPN output transistor
Note: Open or, connect to 0 V.
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
PNP output type
SENSORS
I/O circuit diagram
Terminal arrangement diagram
STATIC
CONTROL
DEVICES
Terminal No.
Color code of connector attached cable
LASER
MARKERS
(Brown) +V
1
D1
PLC
ZD
50 mA MAX.
Tr
2
3
4
1
2
3
4
HUMAN
+
12 to 24 V DC
±10 %
(Black) Comparative output
MACHINE
INTERFACES
D2
−
Load
(White) Not connected (Note)
(Blue) 0 V
ENERGY
MANAGEMENT
SOLUTIONS
Terminal
No.
Designation
FA
COMPONENTS
Internal circuit
Users’ circuit
+V
MACHINE
VISION
Note: Open or, connect to 0 V.
Comparative output
Not connected (Note)
0V
SYSTEMS
UV
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
CURING
SYSTEMS
Tr: PNP output transistor
Note: Open or, connect to 0 V.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
Digital Pressure Sensor DP-0SERIES
709
FIBER
PRECAUTIONS FOR PROPER USE
Refer to p.1566 for general precautions.
SENSORS
LASER
Connection
SENSORS
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
How to connect
PHOTO-
ELECTRIC
SENSORS
Release lever
• Insert the cable with connector
CN-14A(-R)‑C□ into this product’s
connection connector section as shown
in the right figure.
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
• This product is used for non-corrosive gas.
The product shall not be used for liquid
or corrosive gas. Never use fluids having
inflammability, toxicity, etc., that affect the
human body, either.
How to disconnect
CURTAINS
/
SAFETY
• Pressing the release lever of the cable
with connector, pull out the connector.
COMPONENTS
Cable with connector
CN-14A(-R)-C□
PRESSURE /
FLOW
SENSORS
Note: Do not pull by holding the cable without pressing the release lever, as
INDUCTIVE
PROXIMITY
SENSORS
this can cause cable break or connector break.
PARTICULAR
USE
Part description
Factory setting
SENSORS
Digital display unit
Type
Low pressure type
High pressure type
ON mark
SENSOR
OPTIONS
Operation setting
NO/NC setting
Threshold value
Pressure unit
EASY mode
Connecting
connector
OFF mark
SIMPLE
WIRE-SAVING
UNITS
Key lock mark
NC
−50.0
kPa
NO
0.500
MPa
OVER mark
WIRE-SAVING
SYSTEMS
Pressure port
(M5 female thread)
Mode
selection key
MEASURE-
MENT
Setting value UP key
Setting value DOWN key
Display color
Red when ON, White when OFF
2.5 ms
SENSORS
Response speed
STATIC
CONTROL
DEVICES
Piping
• When using this product, connect a joint available in the market
to the pressure port. At the time, the tightening torque should be
1.0 N·m or less.
LASER
Error indication
MARKERS
Error indication
Description
Remedy
PLC
The load is short-circuited
causing an overcurrent to
flow.
Mounting
Turn OFF the power and
check the load.
HUMAN
MACHINE
INTERFACES
• Use sensor mounting bracket MS-DP1-1 prepared
independently.
When mounting this product with sensor mounting bracket, etc.,
the tightening torque should be 0.5 N·m or less.
ENERGY
MANAGEMENT
SOLUTIONS
Applied pressure at the
pressure port should be
Pressure is applied during brought to atmospheric
zero point adjustment.
FA
pressure and zero-point
adjustment should be done
again.
COMPONENTS
MACHINE
VISION
M3 (length 6 mm 0.236 in)
screws with washers
The applied pressure
exceeds the upper limit of
the displayed pressure
range.
SYSTEMS
(Accessory with MS-DP1-1)
UV
CURING
Applied pressure range
should be brought within
the rated pressure range.
SYSTEMS
The applied pressure
exceeds the lower limit
(back pressure) of the
displayed pressure range.
Sensor mounting
bracket MS-DP1-1
(Optional)
Selection
Guide
When other error massage is displayed, contact us.
Pressure/
Digital Display
Others
• Panel mounting bracket MS-DP1-8 (optional) and front protection
cover MS-DP1-3 (optional) are available.
Pressure/
Head-separated
• This product has been developed / produced for industrial use
only.
• The product shall be used only within the rated pressure range.
• Do not apply pressure exceeding the pressure resistance.
Otherwise, destruction of diaphragm occurs, preventing the
product to perform normal operation.
• Do not use during the initial transient time (0.5 sec.) after the
power supply is switched ON.
• The specification may not be satisfied in a strong magnetic field.
• This product is suitable for indoor use only.
• Take care that strong impact such as fall is not given to this
product. Otherwise, it may be destroyed.
• Avoid dust, dirt, and steam.
• Take care that the product does not come into contact with
organic solvents such as thinner.
• Take care that the product does not come into contact with oil or
grease.
• Take care that the product does not come into contact with
strong acid or alkaline.
Flow
• For the method for mounting panel mounting bracket, refer to the
instruction manual that came with the MS-DP1-8.
DP-0
DP-100
DP-M
Wiring
• Make sure that the power supply is OFF while performing the
wiring operation.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual
ground.
• When extending the cable, use a cable whose conductor cross-
section area is 0.3 mm2 or more. The cable can be extended to
up to 10 m 32.808 ft in total length.
• Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
• Do not apply stress directly to the connection cable leader or to
the connector.
• Do not insert wire into the pressure port. Otherwise, destruction
of diaphragm occurs, preventing the product to perform normal
operation.
Digital Pressure Sensor DP-0SERIES
710
DIMENSIONS (Unit: mm in)
FIBER
The CAD data can be downloaded from the website.
Sensor
SENSORS
LASER
SENSORS
DP‑00□
PHOTO-
ELECTRIC
SENSORS
24.9 0.980
20 0.787
Connector
20 0.787
MICRO
30 1.181
PHOTO-
ELECTRIC
SENSORS
4.9 0.193
Display
AREA
SENSORS
2-ø2.5 0.098, 5 0.197 deep
20
0.787
SAFETY LIGHT
30
1.181
ø8.35
ø0.329
CURTAINS
SAFETY
/
COMPONENTS
PRESSURE /
FLOW
SENSORS
M5 female thread, 4 0.157 deep
2-M3 female thread, 4 0.157 deep
1.3 0.051
Setting value DOWN key
Setting value UP key
INDUCTIVE
PROXIMITY
SENSORS
Mode selection key
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Sensor mounting bracket (Optional)
MS-DP1-1
SIMPLE
WIRE-SAVING
UNITS
ø2.3
Assembly dimensions
ø0.091
WIRE-SAVING
SYSTEMS
22
0.866
2-R2.1 R0.083
9.5
14.5
0.374
MEASURE-
MENT
1
0.571
0.039
SENSORS
4.2
0.165
14.5
2-R2.1 R0.083
9.5
0.571
STATIC
21
0.374
CONTROL
DEVICES
0.827
4.2
0.165
20
0.787
30
1.181
20
0.787
13
0.512
LASER
MARKERS
2-ø3.5 ø0.138
24.9
0.980
PLC
4.9 0.193
HUMAN
MACHINE
INTERFACES
ø8.35 ø0.329
45
1.772
20
0.787
R13
R0.512
5.3
(
)
(
)
0.209
30
1.181
45
ENERGY
44
MANAGEMENT
SOLUTIONS
5.5
0.217
t 2
t 0.079
1.732
30
20
0.787
1.772
1.181
t 0.079
t 2
FA
1.3
0.051
15
COMPONENTS
0.591
MACHINE
VISION
Material: Cold rolled carbon steel (SPCC)
(Trivalent uni-chrome plated)
30 1.181
SYSTEMS
UV
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
CURING
SYSTEMS
Sensor mounting bracket (Optional)
MS-DP1-5
Assembly dimensions
Selection
Guide
22.75
0.896
R6.75
R0.266
Pressure/
Digital Display
Pressure/
Head-separated
29.5
1.161
16
0.630
Flow
ø4.5
ø0.177
28
1.102
20
0.787
4.5
0.177
DP-0
8.5 0.335
44.5
30
1.181
DP-100
DP-M
24.9
0.980
1.752
4.9
0.193
20
0.787
49.5
ø8.35 ø0.329
(
)
1.949
t 1.5
t 0.059
2-ø3.5 ø0.138
13.5
0.531
49.5
1.949
20
0.787
20
0.787
28.5
1.122
Material: Stainless steel (SUS304)
Two M3 (length 6 mm 0.236 in) screws with
washers are attached.
1.3
0.051
ø4.5
ø0.177
20
4.5
0.177
26.5
t 1.5
0.787
29.5
1.161
30
1.043
t 0.059
48
1.890
1.181
Digital Pressure Sensor DP-0SERIES
711
FIBER
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
Conversion bushing (Optional)
SENSORS
LASER
SENSORS
MS-DP1-7
PHOTO-
ELECTRIC
SENSORS
Assembly dimensions
MICRO
PHOTO-
15.8
0.622
(
)
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS
/
14
0.551
SAFETY
COMPONENTS
3.5
7.8
0.307
PRESSURE /
FLOW
M5 male thread
0.138
SENSORS
Gasket
0.5
36.4
1.433
(
)
0.020
INDUCTIVE
PROXIMITY
SENSORS
8
11 0.433
10 0.394
PARTICULAR
USE
0.315
SENSORS
Rc1
/
8
female thread
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Material: Brass (Nickel plated)
Weight: 10 g approx.
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
Panel mounting bracket (Optional), Front protection cover (Optional)
STATIC
CONTROL
DEVICES
MS-DP1-8 MS-DP1-3
Mounting drawing with DP‑00□
Panel cut-out dimensions
LASER
MARKERS
When 1 unit is installed
PLC
31−00.4
0
HUMAN
MACHINE
1.220−0.016
INTERFACES
31−00.4 1.220−0.016
0
ENERGY
MANAGEMENT
SOLUTIONS
11
0.433
(39.3 1.547)
12.8
0.504
7.2
0.283
34.5 1.358
Front protection
cover
4.9 0.193
ø8.35 ø0.329
A
FA
When “n” units are installed
horizontally in series
When “n” units are installed
vertically in series
COMPONENTS
MACHINE
VISION
31−00.4
1.220−0.016
20
0.787
31 1.220 × n + 3.5 0.138 × (n-1)
34.5
1.358
SYSTEMS
(
)
0
0
31−0.4
0
1.220−0.016
UV
CURING
SYSTEMS
55 2.165
or more
8.5
0.335
50 1.969
31 1.220 × n +
3.5 0.138 × (n-1)
Panel thickness
dimension 1 to 3 mm
0.039 to 0.118 in
33.4 1.315
Selection
Guide
33.4
1.315
Connector
Pressure/
55 2.165
or more
Digital Display
Pressure/
Head-separated
Note: The panel thickness should be
Note: The panel thickness should be
Flow
1 to 3 mm 0.039 to 0.118 in.
1 to 3 mm 0.039 to 0.118 in.
(52 2.047 max.)
View A
DP-0
DP-100
DP-M
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
CN-14A(-R)-C□
L
Model No.
Cable length L (mm in)
1,000 39.370
35
1.378
50
1.969
(
)
(
)
CN-14A(-R)-C1
CN-14A(-R)-C2
CN-14A(-R)-C3
CN-14A(-R)-C5
8
0.315
8
0.315
(
)
(
)
2,000 78.740
3,000 118.110
5,000 196.850
ø3.7 ø0.146 cable
712
MEMO
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明