HG2-DC12V-F [PANASONIC]

TYPICAL APPLICATIONS; 典型应用
HG2-DC12V-F
型号: HG2-DC12V-F
厂家: PANASONIC    PANASONIC
描述:

TYPICAL APPLICATIONS
典型应用

继电器 功率继电器 信号继电器 光电二极管
文件: 总9页 (文件大小:2526K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Discontinued as of August 31, 2012  
20 AMP POWER RELAY  
HG RELAYS  
TYPICAL APPLICATIONS  
HP relays enjoy wide use in various  
applications, particularly in automation  
controls and remote controls.  
9. Amusement equipment  
Control of equipment in amusement  
parks, etc., control of bowling alley  
equipment, control of fountains in public  
parks  
Applications include:  
1. Industrial machinery  
For controlling positioning, pressure, and  
temperature in molding equipment,  
boilers, pumps, charging pressure  
equipment, measuring and evaluation  
equipment, textile machines, etc.  
2. Machine tools  
Control of positioning and directional  
change in turning machines, lathes,  
borers, etc.  
3. Food processing packing machines  
Automatic control of packing equipment  
for milk and seafood, bottling, canning,  
and packaging  
About Cd-free contacts  
We have introduced Cadmium free type  
products to reduce Environmental  
Hazardous Substances. (The suffix “F”  
should be added to the part number.)  
Please replace parts containing  
Cadmium with Cadmium-free products  
and evaluate them with your actual  
application before use because the life of  
a relay depends on the contact material  
and load.  
Product to be discontinued.  
FEATURES  
1. High-capacity and long life  
The electrical life of this high capacity is  
20A 100,000 operations (250 V AC). It  
can be used for 1.5kW (3-phase 200 V)  
motor control.  
4. Office equipment  
Control of copiers, time recorders, etc.  
5. Coin operate machines  
Control of food, cigarette, and other  
vending machines  
2. High breakdown voltage  
Both between contacts, and between  
contacts and coil, high breakdown  
voltage is 2,000 V for 1 minute.  
3. Easy mounting and wiring  
The terminal arrangement is apparent at  
a glance and wiring is easy. Moreover,  
#250 series tab terminals can be used.  
4. Socket and terminal sockets  
available  
Lineup includes DIN terminal sockets that  
enable the use of DIN rails. The pole  
numbers of the terminal sockets are  
interchangeable and different terminal  
sockets can be used in combination.  
5. UL/CSA approved  
6. Measuring devices and equipment  
For repeating installation of control  
signals and in power amplifiers  
7. Generators, transformers and  
power receiving equipment  
Functional parts in protective equipment,  
functional assistance in automatic  
adjustment equipment, telemeters and  
other remote monitoring equipment  
8. Control of conveyance equipment  
Control panels for elevators, escalators,  
and other conveyance equipment, control  
of all kinds industrial transport equipment  
such as conveyors.  
ORDERING INFORMATION  
HG  
F
Contact arrangement  
2: 2 Form C  
3: 3 Form C  
4: 4 Form C  
Coil voltage  
AC 24, 48, 100, (115), 200, (220), (240) V  
DC 12, 24, 48, 100, (110), 200 V  
Contact material  
F: AgSnO2 type  
The voltage values in parentheses are for order-made products for export.  
Note: UL/CSA approved type is standard.  
ds_61C08_en_hg: 011111D  
1
HG  
Discontinued as of August 31, 2012  
TYPES  
2 Form C  
3 Form C  
4 Form C  
Coil voltage  
Part No.  
Part No.  
Part No.  
24V AC  
48V AC  
HG2-AC24V-F  
HG2-AC48V-F  
HG2-AC100V-F  
HG2-AC115V-F  
HG2-AC200V-F  
HG2-AC220V-F  
HG2-AC240V-F  
HG2-DC12V-F  
HG2-DC24V-F  
HG2-DC48V-F  
HG2-DC100V-F  
HG2-DC110V-F  
HG2-DC200V-F  
HG3-AC24V-F  
HG3-AC48V-F  
HG3-AC100V-F  
HG3-AC115V-F  
HG3-AC200V-F  
HG3-AC220V-F  
HG3-AC240V-F  
HG3-DC12V-F  
HG3-DC24V-F  
HG3-DC48V-F  
HG3-DC100V-F  
HG3-DC110V-F  
HG3-DC200V-F  
HG4-AC24V-F  
HG4-AC48V-F  
HG4-AC100V-F  
HG4-AC115V-F  
HG4-AC200V-F  
HG4-AC220V-F  
HG4-AC240V-F  
HG4-DC12V-F  
HG4-DC24V-F  
HG4-DC48V-F  
HG4-DC100V-F  
HG4-DC110V-F  
HG4-DC200V-F  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.  
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.  
Note: Terminal sockets and sockets are not included. Please order these separately.  
RATING  
1. Coil data  
1) AC coils  
Nominal operating  
current  
[20%] (at 20C 68F)  
Nominal operating  
power  
Max. allowable  
voltage  
(at 40C 104F)  
Coil inductance  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage Drop-out voltage  
(at 20C 68F) (at 20C 68F)  
50Hz  
167mA  
86mA  
60Hz  
150mA  
75mA  
50Hz  
60Hz  
50Hz  
60Hz  
24V AC  
48V AC  
0.441H  
1.717H  
7.457H  
9.868H  
30.39H  
35.99H  
42.06H  
0.299H  
1.195H  
5.174H  
6.844H  
20.71H  
25.00H  
29.97H  
0.204H  
0.817H  
3.540H  
4.685H  
14.16H  
17.48H  
20.48H  
0.416H  
1.660H  
7.216H  
9.531H  
29.00H  
34.82H  
41.68H  
0.290H  
1.163H  
5.039H  
6.648H  
20.14H  
24.27H  
29.06H  
0.199H  
0.795H  
3.444H  
4.557H  
13.79H  
16.89H  
19.87H  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
24V AC  
42mA  
36mA  
80%V or less of 30%V or more of  
nominal voltage nominal voltage  
110%V of  
nominal voltage  
2 Form C  
3 Form C  
4 Form C  
36mA  
31.3mA  
18mA  
4.2VA  
3.6VA  
(Initial)  
(Initial)  
21mA  
19mA  
16.4mA  
15mA  
18mA  
250mA  
125mA  
61mA  
216mA  
108mA  
52mA  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
24V AC  
80%V or less of 30%V or more of  
nominal voltage nominal voltage  
110%V of  
nominal voltage  
52.4mA  
30mA  
45.2mA  
26mA  
6.0VA  
8.8VA  
5.2VA  
7.6VA  
(Initial)  
(Initial)  
27.3mA  
25mA  
23.6mA  
21.6mA  
316mA  
158mA  
76mA  
367mA  
184mA  
88mA  
48V AC  
100V AC  
115V AC  
200V AC  
220V AC  
240V AC  
80%V or less of 30%V or more of  
nominal voltage nominal voltage  
110%V of  
nominal voltage  
76.8mA  
44mA  
66.1mA  
38mA  
(Initial)  
(Initial)  
39mA  
34mA  
36.6mA  
31.6mA  
ds_61C08_en_hg: 011111D  
2
HG  
Discontinued as of August 31, 2012  
2) DC coils  
Nominal operating  
current  
[10%] (at 20C 68F)  
Max. allowable  
voltage  
(at 40C 104F)  
Contact  
arrangement  
Nominal coil  
voltage  
Pick-up voltage Drop-out voltage  
(at 20C 68F) (at 20C 68F)  
Coil resistance  
[10%] (at 20C 68F)  
Nominal operating  
power  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
12V DC  
24V DC  
48V DC  
100V DC  
110V DC  
200V DC  
119.6mA  
57.6mA  
30.3mA  
14.4mA  
14.4mA  
7.2mA  
100  
416  
1.4W  
1.4W  
1.5W  
1.4W  
1.6W  
1.4W  
1.6W  
1.6W  
1.6W  
1.7W  
1.8W  
1.7W  
2.0W  
1.9W  
2.2W  
2.0W  
2.2W  
2.6W  
80%V or less of 10%V or more of  
1,585  
6,950  
7,650  
27,800  
89.5  
110%V of  
nominal voltage  
2 Form C  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
134mA  
66mA  
364  
80%V or less of 10%V or more of  
33.1mA  
16.5mA  
16.5mA  
8.4mA  
1,450  
6,060  
6,670  
23,800  
71.4  
110%V of  
nominal voltage  
3 Form C  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
168mA  
81.2mA  
45.7mA  
20.3mA  
20.3mA  
12.9mA  
296  
80%V or less of 10%V or more of  
1,050  
4,930  
5,420  
15,500  
110%V of  
nominal voltage  
4 Form C  
nominal voltage  
(Initial)  
nominal voltage  
(Initial)  
Notes: 1. The rated current area is15% (60Hz) [AC coils],. 10% (20C) [DC coils]  
2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature.  
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will  
flow leading possibly to coil burnout.  
4. As a general rule, only a pure DC voltage should be used for the coil drive.  
However, a DC power supply that contains ripples has characteristics that differ from pure DC.  
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.  
2. Specifications  
Characteristics  
Item  
Initial contact resistance, max  
Contact material  
Specifications  
Max. 15 m(By voltage drop 6 V DC 1A)  
AgSnO2 type  
Contact  
Nominal switching capacity  
Min. switching capacity (Reference value)*1  
20A 250V AC (resistive load)  
100mA 5V DC  
Rating  
Min. 100M(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
Insulation resistance (Initial)  
Between open contacts  
2,000 Vrms for 1min (Detection current: 10mA.)  
2,000 Vrms for 1min (Detection current: 10mA.)  
2,000 Vrms for 1min (Detection current: 10mA.)  
Breakdown voltage  
Between contact sets  
(Initial)  
Electrical  
Between contact and coil  
characteristics  
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)  
(Nominal voltage applied to the coil, excluding contact bounce time.)  
Operate time*2  
Max. 30ms (2 Form C), Max.40ms (3 Form C, 4 Form C)  
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)  
Release time*2  
Min. 98 m/s2 (Except for contact operating direction)  
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)  
Functional  
Shock resistance  
Mechanical  
characteristics  
Destructive  
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)  
10 to 55 Hz at double amplitude of 2 mm  
Min. 107 (at 180 cpm)  
Min. 106 (at 180 cpm)  
20A 250V AC resistive load (cos=1), Min. 105  
Functional  
Vibration resistance  
Destructive  
AC coil  
Mechanical  
Expected life  
Conditions  
DC coil  
Electrical  
Ambient temperature: –50C to +40C –58F to +104F  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Conditions for operation, transport and storage*3  
Max. Operating speed  
20 cpm (at max. rating)  
Unit weight  
Notes:  
2 Form C: approx. 130g 4.59oz, 3 Form C: approx. 185g 6.53oz, 4 Form C: approx. 240g 8.47oz  
*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load.  
*2 For the AC coil types, the operate/release time will differ depending on the phase.  
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport  
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.  
ds_61C08_en_hg: 011111D  
3
HG  
Discontinued as of August 31, 2012  
REFERENCE DATA  
1. Switching capacity range  
AC resistive  
load  
20  
10  
AC inductive  
load (cosϕ=0.4)  
DC resistive  
load  
DC inductive  
load (L/R=7ms)  
1
0.1  
10  
100  
500 1,000  
Contact voltage, V  
DIMENSIONS(mm inch)  
Download CADData from our Web site.  
2 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
7
2
8.4  
7
3 dia. tapping screw  
.331  
.276  
8
6
5
1
3
4
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
16  
20.5  
.807  
.630  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
15  
.591  
34  
36  
1.339  
1.417  
56  
2.205  
4
8.5  
.157  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
.669  
General tolerance: 0.5 .020  
3 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
3 dia. tapping screw  
10  
2
8.4  
8.4  
7
.331 .331  
.276  
11  
9
1
4
5
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
3
6
7
16  
8
20.5  
.807  
.630  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
17  
.669  
50  
36  
1.969  
1.417  
56  
2.205  
4
8.5  
.157  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
17  
.669 .669  
General tolerance: 0.5 .020  
ds_61C08_en_hg: 011111D  
4
HG  
Discontinued as of August 31, 2012  
4 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
2.5 dia. 9 deep hole for  
3 dia. tapping screw  
10  
1
8.4  
8.4  
7
.331  
.331  
.276  
9
8
7
2
3
4
.098 dia. .354 deep hole for  
.118 dia. tapping screw  
15 11  
14 12  
6 5  
16  
20.5  
.807  
.630  
2.5 dia. 8 deep hole for  
3 dia. tapping screw  
.098 dia. .315 deep hole for  
.118 dia. tapping screw  
34  
1.339  
68  
36  
2.677  
1.417  
56  
2.205  
4
8.5  
.157  
.335  
Compatible with tab terminal  
#250 series receptacle.  
7
.276  
10.5  
.413  
7.5  
.295  
7.26  
.286  
17  
17  
17  
.669 .669 .669  
General tolerance: 0.5 .020  
For Cautions for Use, see Relay Technical Information.  
ds_61C08_en_hg: 011111D  
5
Discontinued as of August 31, 2012  
ACCESSORIES  
(Sockets and  
Terminal sockets)  
HG RELAY  
ACCESSORIES  
Socket  
Products to be discontinued.  
Terminal socket for DIN rail assembly  
TYPES  
1. For DIN rail terminal sockets, sockets and general terminal sockets hold-down clip included.  
2. The terminal socket installation rail can be used also for the square plug-in terminal socket of the timer and the terminal  
socket of the HP relay.  
Packing quantity  
Type  
No. of poles  
Item  
HG2-socket  
Part No.  
Carton  
10 pcs.  
5 pcs.  
5 pcs.  
10 pcs.  
5 pcs.  
Case  
2-pole  
3-pole  
4-pole  
2-pole  
3-pole  
HG2-SS  
HG3-SS  
HG4-SS  
HG2-SFD  
HG3-SFD  
50 pcs.  
25 pcs.  
25 pcs.  
50 pcs.  
25 pcs.  
Socket  
HG3-socket  
HG4-socket  
HG2-DIN terminal socket  
HG3-DIN terminal socket  
DIN rail terminal socket  
Note: For a 4-pole relay with DIN rail terminal socket, use two 2-pole types side by side.  
Socket and terminal socket conform to UL, CSA as standard.  
ds_61C08_en_hg: 011111D  
6
HG  
Discontinued as of August 31, 2012  
DIMENSIONS (Unit: mm inch)  
1. Socket (with hold-down clip)  
HG2-Socket (HG2-SS)  
External dimensions  
Mounting hole diagram  
With a relay mounted  
17±0.1  
31.5±0.5  
22  
.669±.004  
1.240±.020  
.866  
6±0.3  
4.2±0.3  
.236±.012  
6.2±0.3  
.165±.012  
.244±.012  
48±0.5  
1.890±.020  
59±1  
2.323±.039  
40.5  
36.5  
37.5±0.5  
1.594  
1.437  
1.476±.020  
48  
1.890  
6±0.3  
.236±.012  
2-4.2 dia. hole  
(or 2-M4 screw hole)  
14.5  
.571  
17±0.1  
2-.165 dia. hole  
(or 2-M.157 screw hole)  
.669±.004  
22  
Approx.  
23.5  
.925  
.866  
Note: Hold-down clip is  
packaged with the  
socket.  
Compatible with tab terminal  
#250 series receptacle.  
34  
1.339  
30.5  
1.201  
General tolerance: 0.6 .024  
HG3-Socket (HG3-SS)  
External dimensions  
Mounting hole diagram  
With a relay mounted  
17  
48±0.5  
28  
.669  
1.890±.020  
1.102  
4.2±0.3  
6.2±0.3  
6±0.3  
.165±.012  
.244±.012  
.236±.012  
48±0.5  
1.890±.020  
40.5  
59  
2.323  
48  
36.5  
1.594  
1.437  
37.5±0.5  
1.476±.020  
1.890  
6±0.3  
28  
.236±.012  
14.5  
1.102  
2-4.2 dia. hole  
.571  
34  
(or 2-M4 screw hole)  
Approx.  
23.5  
.925  
1.339  
2-.165 dia. hole  
(or 2-M.157 screw hole)  
Compatible with tab terminal  
#250 series receptacle.  
51±1  
Note: Hold-down clip is  
packaged with the  
socket.  
2.008±.039  
47  
1.850  
General tolerance: 0.6 .024  
HG4-Socket (HG4-SS)  
External dimensions  
Mounting hole diagram  
With a relay mounted  
17  
65.5±0.5  
45  
.669  
2.579±.020  
6
1.772  
4.2±0.3  
.165±.012  
6.2±0.3  
.236  
.244±.012  
48±0.5  
59  
2.323  
48  
1.890  
40.5  
36.5  
1.890±.020  
1.594  
1.437  
37.5±0.5  
1.476±.020  
6
17±0.1  
.236  
14.5  
.669±.004  
.571  
45  
2-4.2 dia. hole  
Approx.  
23.5  
.925  
1.772  
51  
(or 2-M4 screw hole)  
2-.165 dia. hole  
(or 2-M.157 screw hole)  
Note: Hold-down clip is  
packaged with the  
socket.  
2.008  
Compatible with tab terminal  
#250 series receptacle.  
68±1  
2.677±.039  
64.5±1  
2.539±.039  
General tolerance: 0.6 .024  
ds_61C08_en_hg: 011111D  
7
HG  
Discontinued as of August 31, 2012  
2. Terminal socket for DIN rail assembly (with hold-down clip and installation screw)  
HG2-Terminal socket for DIN rail assembly (HG2-SFD)  
With a relay mounted  
Note: Hold-down clip is packaged with the terminal socket.  
External dimensions  
Schematic  
Mounting hole diagram  
* Installation screw block  
2
10±0.2  
7
26±0.2  
26±0.2  
.394±.008  
1.024±.008  
1.024±.008  
(installation screw, hexagonal nut,  
spring washer)  
26±0.6  
21±0.6  
1
8
.827±.024  
1.024±.024  
17±0.2  
.669±.008  
10±0.6  
.394±.024  
M4 screw  
M.157  
Hold-down clip  
4.5±0.3  
.177±.012  
6
±0.3  
.236±.012  
80  
3.150  
69±0.2  
3
6
2.717±.008  
0.56±0.15  
.022±.006  
69±1  
2.717±.039  
10.44±0.2  
.411±.008  
7.56±0.2  
.298±.008  
4
5
58±1  
80±1  
3.150±.039  
2.283±.039  
2-M4 screw hole  
2
.079  
34  
34  
1.339  
(or 4.2±0.1 dia. hole)  
1.339  
7.26±0.2  
2-M.157 screw hole  
(or .165±.004 dia. hole)  
.286±.008  
Panel hole dimensions  
for side-by-side installation  
9±0.3  
HG2 relay  
34.5±0.6  
1.358±.024  
36±0.6  
.354±.012  
34±0.6  
Tolerance: 0.1 .004  
1.339±.024  
1.417±.024  
*For direct mounting, use the included installation screw  
block.  
HG3-Terminal socket for DIN rail assembly (HG3-SFD)  
With a relay mounted  
Note: Hold-down clip is packaged with the terminal socket.  
External dimensions  
Schematic  
Mounting hole diagram  
* Installation screw block  
2
12  
10  
10±0.2  
.394±.008  
43±0.2  
43±0.2  
(installation screw, hexagonal nut,  
spring washer)  
43±0.6  
1.693±.024  
17±0.2 17±0.2  
.669±.008 .669±.008  
21±0.6  
1
3
11  
1.693±.008  
1.693±.008  
.827±.024  
10±0.6  
M4 screw  
M.157  
Hold-down clip  
4.5±0.3  
.177±.012  
6±0.3  
.394±.024  
.236±.012  
80  
3.150  
4
6
9
69±1  
2.717±.039  
69±0.5  
2.717±.020  
0.56±0.15  
.022±.006  
10.44±0.2  
.411±.008  
7.56±0.2  
.298±.008  
80±1  
58±1  
5
7
8
3.150±.039  
2.283±.039  
2
.079  
51  
51  
2.008  
2.008  
2-M4 screw hole  
7.26±0.2  
.286±.008  
(or 4.2±0.1 dia. hole)  
Panel hole dimensions  
for side-by-side installation  
2-M.157 screw hole  
(or .165±.004 dia. hole)  
9±0.3  
HG2 relay  
34.5±0.6  
.354±.012  
1.358±.024  
Tolerance: 0.1 .004  
*For direct mounting, use the included installation screw  
block.  
51±0.6  
36±0.6  
2.008±.024  
1.417±.024  
ds_61C08_en_hg: 011111D  
8
HG  
Discontinued as of August 31, 2012  
With 4-pole HG relays, use two HG2-Terminal sockets  
for DIN rail assembly side by side.  
With a relay mounted  
Schematic for terminal socket and relay  
1
2
7
2
7
10  
9
2
1
15  
1
3
8
8
11  
Note: The plain numbers  
denote the terminal  
socket terminal  
HG4  
number. The white  
numbers in black  
circles denote the  
relay terminal  
3
6
6
3
4
12  
14  
8
6
7
5
4
5
4
5
number.  
Note: Hold-down clip is packaged with the terminal socket.  
(TOP VIEW)  
OTHER WAYS TO MOUNT RELAYS  
With direct mounting by cover tapping  
(Tab terminal connection)  
Compatible with #250 series  
Mounting hole diagram  
2-3.5 dia. hole  
2-.138 dia.  
HG2  
A
(Dimension A)  
HG2: 15mm .591inch  
HG3: 17mm .669inch  
HG4: 34mm 1.339inch  
3 dia. tapping screw  
.118 dia.  
TERMINAL SOCKET (SOCKET) COMBINATION  
Because the pole numbers of the terminal sockets (sockets) are interchangeable,  
different terminal sockets (sockets) can be used in combination.  
HG4  
HG2  
HG2  
HG2  
HG4 main unit Æ HG2 terminal socket + HG2 terminal socket  
HG2 main unit + HG2 main unit + HG2 main unit Æ HG3 terminal socket + HG3 terminal socket  
HG3  
HG3  
HG3 main unit + HG3 main unit Æ HG2 terminal socket + HG2 terminal socket + HG2 terminal socket  
NOTES  
1. Hold-down clip  
the direction of contact switching. (In  
4. Do not insert or remove relays into  
or out of live circuits.  
5. To prevent damage or distortion,  
when tightening fixing screws, the  
optimum torque range should be 1.176  
to 1.37 N·m (12 to 14 kgf·cm).  
Please use the hold-down clip whenever  
HG relays will be used in applications  
where strong vibrating or shock force  
occurs.  
direction of contact switching operation,  
resistance to external shock is more than  
98 m/s2). Moreover, if the mounted relay  
is likely to be susceptible to strong  
vibrations or shocks, be sure to fit the  
hold-down clip.  
2. Mounting direction  
There is no restriction on the mounting  
direction. However, if the mounted relay  
will be susceptible to strong vibrations or  
shocks, to avoid influence on switching  
operations, mount so that the direction of  
vibration and shock are not in line with  
3. Environment  
Avoid use in adverse conditions, such as  
where there is exposure to harmful gas,  
or where ambient temperatures are high  
(more than 40C).  
For Cautions for Use, see Relay Technical Information.  
ds_61C08_en_hg: 011111D  
9

相关型号:

HG2-DC200V

Power/Signal Relay, DPDT, Momentary, 0.007A (Coil), 200VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC200V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC24V

20 AMP POWER RELAY
PANASONIC

HG2-DC24V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC48V

Power/Signal Relay, DPDT, Momentary, 0.03A (Coil), 48VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount,
PANASONIC

HG2-DC48V-F

TYPICAL APPLICATIONS
PANASONIC

HG2-DC6V

Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, DIN-Rail Mount
PANASONIC

HG2-DC6V-F

Power/Signal Relay, DPDT, Momentary, 0.23A (Coil), 6VDC (Coil), 1400mW (Coil), DC Input, AC Output, Socket Mount, ROHS COMPLIANT
PANASONIC

HG2-SS

Relay Socket
PANASONIC

HG20000000J0G

Barrier Strip Terminal Block
AMPHENOL

HG20002000J0G

Barrier Strip Terminal Block
AMPHENOL

HG20004000J0G

Barrier Strip Terminal Block
AMPHENOL