HL-T1CCJ8 [PANASONIC]

Ultra-compact Laser Collimated Beam Sensor;
HL-T1CCJ8
型号: HL-T1CCJ8
厂家: PANASONIC    PANASONIC
描述:

Ultra-compact Laser Collimated Beam Sensor

文件: 总12页 (文件大小:903K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ultra-compact Laser Collimated Beam Sensor  
1111  
HL-T1 SERIES  
General terms and conditions............. F-3  
Selection guide............................ P.1021~  
About laser beam......................... P.1593~  
FIBER  
SENSORS  
Related Information  
Glossary of terms / General precautions ..... P.1587 / P.1595  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
Conforming to  
FDA regulations  
(
)
HL-TF only  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
This product is classified as a  
Class 1 Laser Product in IEC /  
JIS standards and a Class II  
Laser Product in FDA regulations.  
Do not look at the laser beam  
through optical system such as  
a lens.  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
panasonic.net/id/pidsx/global  
STATIC  
CONTROL  
DEVICES  
LASER  
Ultra-compact sensor head A high-functionality  
intelligent controller  
MARKERS  
PLC  
HUMAN MACHINE  
INTERFACES  
Ultra-compact sensor head  
Resolution of 4 µm 0.157 mil  
ENERGY  
MANAGEMENT  
SOLUTIONS  
The ultra-compact size and yet the high level of performance.  
These sensors save space.  
A high resolution of 4 μm 0.157 mil (at an average  
64 cycles) allows high-precision positioning and size  
judgment.  
FA COMPONENTS  
HL-T1001A(F)  
HL-T1005A(F)  
HL-T1010A(F)  
MACHINE VISION  
SYSTEMS  
Emitter  
34 mm  
1.339 in  
Emitter  
Distinguishing size of  
electronic components  
15mm 0.591 in  
UV CURING  
SYSTEMS  
20 mm 0.787 in  
42 mm  
1.654 in  
15 mm 0.591 in  
20 mm  
0.7487 in  
19 mm 0.748 in  
15 mm 0.591 in  
15 mm  
0.591 in  
20 mm  
0.787 in  
25 mm  
0.984 in  
20 mm  
0.787 in  
Selection  
Guide  
Laser  
Displacement  
Receiver  
Receiver  
Magnetic  
Displacement  
Contact  
BASIC PERFORMANCE  
Long sensing range  
Displacement  
Collimated  
Beam Sensors  
Metal-sheet  
Double-feed Detection  
Minimum sensing object  
diameter ø8 µm ø0.315 mil  
HL-T1001A(F)  
Digital Panel  
Controller  
Long sensing range of 500 mm 19.685 in  
[HL-T1005A(F), HL-T1010A(F)] and 2 m 6.562 ft  
[HL-T1001A(F)] are available.  
The laser with a beam  
diameter of ø1 mm  
ø0.039 in can sense  
extremely small objects  
with dimensions in  
micrometers such as  
bonding wires.  
Other Products  
HL-T1  
LD  
High-precision judgment even from  
minute differences in light intensity  
LA  
The sensors are sensitive  
Distinguishing opacity of glass  
to minute differences in  
light intensity, so that  
they can judge even  
the opacity of glass.  
In addition, the amount  
of light received can be  
displayed as a percentage  
to allow you to determine  
permeation rates.  
Adoption of a Class 1 laser  
The adoption of a Class 1 laser (IEC / JIS) eliminates the  
need for safety countermeasures, so that these sensors  
can be used in photoelectric sensor applications with  
confidence.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1112  
APPLICATIONS  
FIBER  
SENSORS  
LASER  
SENSORS  
Checking the positioning of chip components  
Detecting defective lead frame seating  
Sensing wafer position in wafer cassette  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
FUNCTIONS  
Fully equipped with convenient functionality  
Analog output is switchable between current / voltage  
SENSOR  
OPTIONS  
A wide range of convenient features has been incorporated  
into the unit’s compact body: standard received light setting  
/ auto scaling setting / measurement processing (various  
timer and hold functions) / differentiation / monitor focus  
function. These features make the unit useful for a wide  
variety of applications.  
The analog output can be switched between either of  
two different outputs; current (4 to 20 mA) / voltage  
(±4 V). With the monitor focus function, the output can  
be adjusted over the range from –5 V to +5 V, or from  
0 V to +5 V, facilitating connectivity with a variety of  
output devices.  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
3 types of teaching functions are now available  
Monitor focus function  
The linear output is fully adjustable over the following  
range (current: 4 to 20 mA / voltage: ±4 V). The usage  
of the monitor focus function together with selectable  
current / voltage switching for the linear output allows for  
compatibility with a variety of output devices.  
(Examples)  
3 types of teaching functions are available: positioning  
teaching / 2-point teaching / automatic teaching, thus  
enabling a variety of applications to be accommodated  
for many different types of production sites.  
LASER  
MARKERS  
PLC  
HUMAN MACHINE  
INTERFACES  
The actual value measured at the time when teaching  
Positioning  
is performed is utilized as the threshold value.  
teaching  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Best suited for high-precision positioning.  
+4  
In this teaching method, an intermediate level between  
the first and the second teaching levels is utilized as  
FA COMPONENTS  
the threshold value. Minute differences, such as  
changes as small as the thickness of a sheet of paper  
between the sensing objects, can be detected when  
this teaching method is utilized.  
2-point  
teaching  
MACHINE VISION  
SYSTEMS  
–4  
With this teaching method, a series of periodic arbitrarily  
measurements are taken automatically and an  
intermediate value, between the maximum and minimum  
values obtained by this measurement, is utilized as the  
threshold value. The threshold value is therefore set in  
relation to the sensing object. Best suited for  
UV CURING  
SYSTEMS  
Automatic  
teaching  
0
5.0  
0.197  
Sensor display value (mm in)  
applications in which teaching must be performed  
without stopping the current flow of operations.  
In the event that  
In the event that  
5 mm 0.197 in: +1 V  
0 mm 0 in: +5 V  
5 mm 0.197 in: +5 V  
0 mm 0 in: +1 V  
Selection  
Guide  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam Sensors  
Metal-sheet  
Double-feed Detection  
Digital Panel  
Controller  
Detection resolution can be easily confirmed  
The current resolution can be easily confirmed by setting  
the controller to indicate resolution display mode.  
By displaying the resolution, the marginal increment can  
be easily determined for the threshold value setting,  
helping to accurately determine whether sensing can be  
+5  
+1  
+5  
+1  
performed.  
Resolution  
indicator  
Other Products  
0
5.0  
0
5.0  
0.197  
0.197  
Sensor display value (mm in)  
Sensor display value (mm in)  
HL-T1  
LD  
The linear output must be set by determining output  
values (maximum; current: 0 to 23.5 mA / voltage: 5.5 V)  
at two different points, for the arbitrary display value.  
LA  
MAINTENANCE  
Self-check for laser diode deterioration  
The intelligent controller performs self-checking for laser  
diode deterioration. If the controller detects significant  
deterioration (end of diode life), an error will be displayed  
on the main digital display panel. This function enables  
users to prepare in advance for potential laser diode  
malfunctions.  
Error display  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1113  
OPERABILITY  
OPTIONS  
FIBER  
SENSORS  
Superior operability has been achieved  
Calculations for 2 sensors are possible  
LASER  
SENSORS  
All settings can be easily performed by using the four-way  
keys and viewing the digital displays.  
The calculation unit (optional) just needs to be connected  
between the two controllers to enable calculations (addition  
and subtraction) to be carried out for two sensors. No digital  
panel controller is needed either.  
PHOTO-  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
Large dual digital display  
ELECTRIC  
SENSORS  
After power up, the measured value (red) and the  
threshold value (yellow) are displayed  
(letter height 7 mm 0.276 in)  
AREA  
SENSORS  
Judgment output indicators  
SAFETY LIGHT  
Sheet width measurement  
CURTAINS  
/
HIGH (Orange) / PASS (Green) / LOW  
(Yellow) 3-color display  
SAFETY  
COMPONENTS  
Calculation unit  
HL-AC1-CL  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
SENSORS  
SENSOR  
OPTIONS  
Easy operation with four-way keys  
SIMPLE  
WIRE-SAVING  
UNITS  
ORDER GUIDE  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
Sensor heads  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Min. sensing  
object  
Conforming  
standards / regulations  
Type  
Appearance  
Sensing range  
Sensing width  
Model No.  
LASER  
MARKERS  
ø8 µm ø0.315 mil  
opaque object  
ø50 µm ø1.969 mil  
opaque object at  
500 to 2,000 mm  
ø1 mm ø0.039 in  
ø1 to ø2.5 mm  
ø0.039 to ø0.098 in  
at 500 to 2,000 mm  
19.685 to 78.740 in  
sensing range  
IEC / JIS  
HL-T1001A  
PLC  
2 m 6.562 ft  
HUMAN  
MACHINE  
INTERFACES  
19.685 to 78.740 in  
sensing range  
FDA /  
IEC / JIS  
ENERGY  
MANAGEMENT  
SOLUTIONS  
HL-T1001F  
HL-T1005A  
HL-T1005F  
HL-T1010A  
HL-T1010F  
FA  
COMPONENTS  
MACHINE  
VISION  
IEC / JIS  
SYSTEMS  
ø0.05 mm ø0.002 in  
opaque object  
500 mm 19.685 in  
UV  
CURING  
5 mm 0.197 in  
SYSTEMS  
FDA /  
IEC / JIS  
Selection  
Guide  
IEC / JIS  
Laser  
Displacement  
ø0.1 mm ø0.004 in  
opaque object  
Magnetic  
500 mm 19.685 in  
10 mm 0.394 in  
Displacement  
Contact  
Displacement  
FDA /  
IEC / JIS  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Note: The model No. with “P” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver.  
Digital Panel  
Controller  
Other  
Products  
Accessories  
• MS-HLT1-1  
Sensor mounting bracket  
• MS-LA3-1  
• CN-HLT1-1  
(Sensor head to controller connection cable)  
HL-T1  
LD  
Sensor mounting bracket  
for HL-T1010A(F)  
(Note)  
HL-T1001A(F) /  
for  
HL-T1005A(F)  
(Note)  
LA  
Two M3 (length 25 mm 0.984 in)  
screws with washers are attached.  
Two M3 (length 20 mm 0.787 in)  
screws with washers are attached.  
Note: 2 sets are required to mount  
the emitter/receiver.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1114  
ORDER GUIDE  
FIBER  
SENSORS  
LASER  
Controllers  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
Type  
Appearance  
Model No.  
Output  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
NPN open-collector transistor  
(Judgment output)  
Current/voltage output  
(Linear output)  
SENSORS  
HL-AC1  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PNP open-collector transistor  
(Judgment output)  
Current/voltage output  
(Linear output)  
PARTICULAR  
USE  
HL-AC1P  
SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Calculation unit  
WIRE-SAVING  
SYSTEMS  
Appearance  
Model No.  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
HL-AC1-CL  
MARKERS  
PLC  
HUMAN  
MACHINE  
INTERFACES  
OPTIONS  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Side-view attachment  
FA  
COMPONENTS  
Designation  
Model No.  
Description  
• HL-T1SV1  
• HL-T1SV2  
MACHINE  
VISION  
SYSTEMS  
For HL-T1001A(F) /  
T1005A(F) (1 pc.)  
HL-T1SV1  
UV  
The beam axis can be bent to a right  
angle making universal mounting  
possible.  
Side-view  
attachment  
CURING  
SYSTEMS  
For HL-T1010A(F)  
(1 pc.)  
HL-T1SV2  
Controller  
mounting bracket  
Use when mounting the controller with screws.  
MS-HLAC1-1  
HL-T1CCJ4  
HL-T1CCJ8  
Selection  
Guide  
Extension cable for use between the controller  
Length: 4 m 13.123 ft  
Net weight: 162 g approx.  
Laser  
and its cable linking it with the sensor head.  
Cabtyre cable with connectors on both ends  
Cable outer diameter: ø5.2 mm ø0.205 in  
Connector outer diameter:  
Displacement  
Mounted on both sides  
Mounted on one side only  
Magnetic  
Extension cable  
Displacement  
Length: 8 m 26.247 ft  
Net weight: 330 g approx.  
Contact  
Displacement  
Controller mounting bracket  
• MS-HLAC1-1  
ø15.5 mm ø0.610 in max.  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
Other  
Products  
HL-T1  
LD  
LA  
Extension cable  
• HL-T1CCJ4  
• HL-T1CCJ8  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1115  
SPECIFICATIONS  
FIBER  
SENSORS  
LASER  
Sensor heads  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
Type  
Beam diameter ø1 mm ø0.039 in type Sensing width 5 mm 0.197 in type Sensing width 10 mm 0.394 in type  
IEC / JIS conformed type  
FDA conformed type  
HL-T1001A  
HL-T1001F  
HL-T1005A  
HL-T1010A  
HL-T1010F  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Item  
HL-T1005F  
EMC Directive, RoHS Directive  
HL-AC1, HL-AC1P  
CE marking directive compliance  
Applicable controller  
Sensing range  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
/
0 to 500 mm 0 to 19.685 in 500 to 2,000 mm 19.685 to 78.74 in  
500 mm 19.685 in  
SAFETY  
COMPONENTS  
Sensing width  
ø1 mm ø0.039 in  
ø1 to ø2.5 mm ø0.039 to ø0.098 in  
5 mm 0.197 in  
10 mm 0.394 in  
PRESSURE /  
FLOW  
ø8 µm ø0.315 mil ø50 µm ø1.969 mil  
Min. sensing object  
ø0.05 mm ø0.002 in opaque object  
ø0.1 mm ø0.004 in opaque object  
SENSORS  
opaque object  
opaque object  
INDUCTIVE  
PROXIMITY  
SENSORS  
Repeatability  
(During the state in which light is half blocked)  
4 µm 0.157 mil  
(Note 2)  
4 µm 0.157 mil (Note 2)  
4 µm 0.157 mil (Note 2)  
Green LED (lights up during laser emission)  
PARTICULAR  
USE  
Linear output resolution  
(Note 3)  
4 µm 0.157 mil  
(Note 2, 4)  
SENSORS  
SENSOR  
OPTIONS  
Emission indicator  
Interference prevention function  
Pollution degree  
Two units of sensors can be mounted close together. (When the controller interference prevention function is used)  
3 (industrial environment)  
SIMPLE  
WIRE-SAVING  
UNITS  
Ambient temperature  
Ambient humidity  
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –25 to +70 °C –13 to +158 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
WIRE-SAVING  
SYSTEMS  
Ambient illuminance  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Incandescent light: 10,000 ℓx or less at the light-receiving face  
MEASURE-  
MENT  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
100 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each  
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
Red semiconductor laser Class 1 (IEC / JIS)  
Red semiconductor laser Class 1 (IEC / JIS)  
modulated, max. output: 0.2 mW, peak  
emission wavelength: 650 nm 0.026 mil  
modulated, max. output: 0.35 mW,  
peak emission wavelength: 650 nm 0.026 mil  
IEC / JIS conformed type  
FDA conformed type  
PLC  
HUMAN  
MACHINE  
INTERFACES  
Red semiconductor laser Class II (FDA)  
Red semiconductor laser Class II (FDA)  
ENERGY  
MANAGEMENT  
SOLUTIONS  
modulated, max. output: 0.35 mW,  
peak emission wavelength: 650 nm 0.026 mil  
modulated, max. output: 0.2 mW, peak  
emission wavelength: 650 nm 0.026 mil  
(IEC / JIS: Class 1)  
(IEC / JIS: Class 1)  
FA  
COMPONENTS  
Material  
Enclosure: Polyetherimide, Case cover: Polycarbonate, Front cover: Glass  
0.09mm2 3-core shielded cable with connector, 0.5 m 1.640 ft long  
Extension up to total 10 m 32.808 ft is possible, with the optional cable.  
MACHINE  
VISION  
Cable  
SYSTEMS  
Cable extension  
Net weight  
UV  
CURING  
Emitter: 15 g approx., Receiver: 15 g approx.  
Emitter: 30 g approx., Receiver: 20 g approx.  
SYSTEMS  
MS-HLT1-1(Sensor head mounting bracket): One set of two brackets for both  
the emitter and the receiver  
CN-HLT1-1(Sensor head to controller connection cable): 1 cable  
Laser beam alignment sticker: 2 pcs.  
MS-LA3-1 (Sensor head mounting bracket):  
One set of two brackets for both the emitter and the receiver  
CN-HLT1-1 (Sensor head to controller connection cable): 1 cable  
Laser beam alignment sticker: 2 pcs.  
Label set (FDA conformed type only): 1 set  
Accessories  
Label set (FDA conformed type only): 1 set  
Selection  
Guide  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.  
2) In case of an average sampling rate of 64 times.  
Laser  
Displacement  
3) Value calculated with the linear output allowance factor (±3 σ) when connected to the controller included in the calculation of the detection width.  
4) This value was obtained by converting the range of linear output fluctuation (±3 σ) into a sensing width, assuming that the smallest sensing object  
blocks the beam at the approximate center of the beam diameter of ø1 mm ø0.039 in.  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam  
Calculation unit  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Model No.  
HL-AC1-CL  
Digital Panel  
Controller  
Item  
Other  
Products  
CE marking directive compliance  
Connected controller  
Current consumption  
Connecting method  
Connection indicator  
Ambient temperature  
Ambient humidity  
Voltage withstandablity  
Insulation resistance  
Vibration resistance  
Shock resistance  
EMC Directive, RoHS Directive  
HL-AC1, HL-AC1P  
12 mA or less (supplied from the controller)  
HL-T1  
LD  
Connector  
Orange LED (lights up when connected to the controller)  
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –15 to +60 °C +5 to +140 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
LA  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
100 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min.  
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each  
Enclosure: ABS, Indicator part: Acrylic  
Material  
Weight  
Net weight: 50 g approx.  
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1116  
SPECIFICATIONS  
FIBER  
SENSORS  
LASER  
Controllers  
SENSORS  
PHOTO-  
Type  
NPN output  
PNP output  
ELECTRIC  
SENSORS  
Item  
Model No.  
HL-AC1  
HL-AC1P  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
CE marking directive compliance  
Applicable sensor head  
Supply voltage / Current consumption  
Measuring cycle  
EMC Directive, RoHS Directive  
HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F  
12 to 24 V DC ±10 % Ripple P-P 10 % or less / 190 mA or less (when connected to the sensor head)  
150 μs  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
Current / voltage output switchable (Note 2)  
COMPONENTS  
During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ω  
During voltage output: ±4 V/F.S., Output impedance 100 Ω  
(In the monitor focus function, it can also be set at ±5 V, 0 to 5 V, etc.)  
Linear output  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Temperature characteristics  
±0.2 % F.S./°C (Note 3)  
Settable average sampling rate (Note 4)  
1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096  
PARTICULAR  
USE  
NPN open-collector transistor  
• Maximum sink current: 50 mA  
Applied voltage: 30 V DC or less (between judgment output and 0 V)  
• Residual voltage: 1.2 V or less (at 50 mA sink current)  
PNP open-collector transistor  
• Maximum source current: 50 mA  
SENSORS  
Judgment outputs  
(HIGH, PASS, LOW)  
Applied voltage: 30 V DC or less (between judgment output and +V)  
SENSOR  
OPTIONS  
• Residual voltage: 2 V or less (at 50 mA source current)  
Utilization category  
Number of outputs  
DC-12 or DC-13  
SIMPLE  
WIRE-SAVING  
UNITS  
HIGH / PASS / LOW 3 values output  
HIGH: ON when measured value > HIGH threshold value  
PASS: ON when HIGH threshold value ≥ measured value ≥ LOW threshold value  
LOW: ON when LOW threshold value > measured value  
WIRE-SAVING  
SYSTEMS  
Output operation  
Short-circuit protection  
Laser OFF input  
MEASURE-  
MENT  
Incorporated  
SENSORS  
0 V connection: Laser emission halt  
Open: Laser emission  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
+V connection: Laser emission halt  
Open: Laser emission  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
STATIC  
CONTROL  
DEVICES  
LASER  
0 V connection: Zero reset operates  
Open: Zero reset ineffective  
+V connection: Zero reset operates  
Open: Zero reset ineffective  
MARKERS  
Zero reset input  
Timing input  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
PLC  
0 V connection: Effective  
Open: Ineffective  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
+V connection: Effective  
Open: Ineffective  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
HUMAN  
MACHINE  
INTERFACES  
0 V connection: Effective  
Open: Ineffective  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
+V connection: Effective  
Open: Ineffective  
• Applied voltage: 30 V DC or less (leak current: 0.1 mA or less)  
ENERGY  
Reset input  
MANAGEMENT  
SOLUTIONS  
Laser emitting (LD ON)  
Judgment outputs  
Green LED (lights up during laser emission)  
HIGH: Orange LED (lights up when measured value > HIGH threshold value)  
PASS: Green LED (lights up when HIGH threshold value measured value LOW threshold value)  
FA  
COMPONENTS  
MACHINE  
VISION  
LOW: Yellow LED (lights up when LOW threshold value measured value)  
>
SYSTEMS  
Enable (ENABLE)  
Zero reset (ZERO)  
Green LED (lights up during normal operation)  
UV  
CURING  
SYSTEMS  
Green LED (lights up when the zero reset function is enabled)  
RUN mode: Either the measured value (mm) or the hold value will be displayed.  
Reverse mode: The display orientation will be reversed.  
Main digital display  
Sub-digital display  
5 digit red LED display  
RUN mode: Either the resolution or laser beam reception amount will be displayed.  
THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.  
5 digit yellow LED display  
Selection  
Guide  
Laser  
• Measured value  
display  
• Setting value, light  
amount value  
resolution display  
• Standard received light • Bottom hold  
setting  
• Automatic scaling  
• Scaling  
• Display reverse  
• ECO display  
• Display digits limitation • ON-delay timer  
• Sample hold  
• Peak hold  
• Zero reset  
• Initial reset  
• Positioning teaching  
• 2-point teaching  
• Automatic teaching  
• Hysteresis width variability  
• Monitor focus  
• (A + B) calculation  
(Note 5)  
• Mutual interference  
prevention (Note 5)  
• Laser deterioration  
detection  
Displacement  
Magnetic  
Displacement  
• OFF-delay timer  
• One-shot timer  
• Differentiation  
• Sensitivity selection  
• Threshold value direct • (A – B) calculation  
Contact  
Displacement  
Main functions  
Collimated  
• Non-measuring time  
setting  
Beam  
Sensors  
• Peak to peak hold  
• Self peak hold  
• Self bottom hold  
• Key lock  
• Zero reset memory  
Metal-sheet  
Double-feed  
Detection  
setting  
(Note 5)  
Digital Panel  
Controller  
Pollution degree  
Ambient temperature  
Ambient humidity  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Material  
3 (industrial environment)  
Other  
Products  
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: –25 to +65 °C –13 to +149 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure  
10 to 150 Hz frequency, 0.7 mm 0.028 in double amplitude in X, Y and Z directions for 80 min.  
300 m/s2 acceleration (30 G approx.) in X, Y and Z directions three times each  
Enclosure: Polybutylene terephthalate, Transparent cover: Polycarbonate  
0.09 mm2 10-core composite cable, 2 m 6.562 ft long  
HL-T1  
LD  
LA  
I/O cable  
I/O cable extension  
Weight  
Extension up to total 10 m 32.808 ft is possible, with 0.09 mm2 or more, cable. (Note 6)  
Net weight: 140 g approx.  
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.  
2) Switching between current and voltage is accomplished by a switch on the bottom of the controller.  
3) This is a typical value when the sensor head is connected.  
4) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) × (Set average sampling rate + 1).  
5) The calculation unit is necessary.  
6) If the extension cable is longer than 10 m 32.808 ft, then it will not qualify for CE marking.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1117  
FIBER  
I/O CIRCUIT DIAGRAMS  
SENSORS  
LASER  
SENSORS  
NPN output type  
PNP output type  
HL-AC1  
HL-AC1P  
PHOTO-  
ELECTRIC  
SENSORS  
Color code  
(Brown) +V  
Color code  
(Brown) +V  
MICRO  
PHOTO-  
D
D
(White) HIGH  
judgment output  
Tr1  
ELECTRIC  
SENSORS  
Load  
50 mA max.  
Tr1  
Load  
(White) HIGH judgment output  
50 mA max.  
(Green) PASS judgment output  
AREA  
Tr2  
Load  
ZD1  
ZD1  
Load  
50 mA max.  
SENSORS  
+
+
12 to 24 V DC  
Tr2  
12 to 24 V DC  
±10 %  
±10 %  
(Green) PASS judgment output  
SAFETY LIGHT  
50 mA max.  
(Gray) LOW judgment output  
Tr3  
Load  
Load  
ZD2  
ZD2  
CURTAINS  
/
50 mA max.  
Tr3  
SAFETY  
COMPONENTS  
(Gray) LOW judgment output  
50 mA max.  
PRESSURE /  
FLOW  
ZD3  
(Blue) GND (0 V)  
(Blue) GND (0 V)  
ZD3  
SENSORS  
(Pink) LD-OFF input  
* 1  
* 1  
* 1  
* 1  
(Pink) LD-OFF input  
(Violet) Timing input  
(Orange / Violet) Zero reset input  
(Red) Reset input  
* 1  
* 1  
* 1  
* 1  
INDUCTIVE  
PROXIMITY  
SENSORS  
(Violet) Timing input  
(Orange / Violet) Zero reset input  
(Red) Reset input  
PARTICULAR  
USE  
SENSORS  
SENSOR  
OPTIONS  
Current output  
4 to 20 mA  
Current output  
4 to 20 mA  
(Black) Linear output  
(Black) Linear output  
Current output:  
300 Ω or less  
Voltage output:  
10 kΩ or more  
SIMPLE  
WIRE-SAVING  
UNITS  
Current output:  
300 Ω or less  
Voltage output:  
10 kΩ or more  
Voltage  
output ±4 V  
Voltage  
output ±4 V  
Load  
Load  
100Ω  
100Ω  
(Shield) Linear GND  
Users’ circuit  
(Shield) Linear GND  
WIRE-SAVING  
SYSTEMS  
Internal circuit  
Internal circuit  
Users’ circuit  
MEASURE-  
MENT  
Symbols … D: Reverse supply polarity protection diode  
Symbols … D: Reverse supply polarity protection diode  
ZD1, ZD2, ZD3: Surge absorption zener diode  
Tr1, Tr2, Tr3: PNP output transistor  
SENSORS  
ZD1, ZD2, ZD3: Surge absorption zener diode  
Tr1, Tr2, Tr3: NPN output transistor  
STATIC  
CONTROL  
DEVICES  
* 1  
* 1  
LASER  
Non-voltage contact or NPN open-collector transistor  
Non-voltage contact or PNP open-collector transistor  
MARKERS  
or  
or  
PLC  
HUMAN  
MACHINE  
• LD-OFF input, Timing input, Zero reset input, Reset inpu  
Low (0 to 1.5 V): Effective  
t
• LD-OFF input, Timing input, Zero reset input, Reset inpu  
Low (0 V or open): Ineffective  
t
INTERFACES  
High (+V or open): Ineffective  
High [ +V to ( +V –1.5 V)]: Effective  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
SENSING CHARACTERISTICS (TYPICAL)  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
HL-T1001A HL-T1001F  
HL-T1005A HL-T1005F  
UV  
CURING  
SYSTEMS  
Correlation between transverse  
deviation and output voltage  
Correlation between transverse  
deviation and output voltage  
Correlation between interrupted  
beam width and output voltage  
8
8
8
Horizontal direction  
2 m 6.562 ft  
Vertical direction  
250 mm 9.843 in  
Sensing object  
Horizontal direction  
500 mm 19.685 in  
Vertical direction  
2 m 6.562 ft  
500 mm 19.685 in  
Receiver  
Receiver  
Emitter  
Receiver  
+
Receiver  
Receiver  
Emitter  
Emitter  
Emitter  
Emitter  
6
4
2
0
6
4
2
6
4
2
0
Selection  
Guide  
500 mm  
19.685 in  
Laser  
The graph depicts the  
correlation between  
transverse deviation and  
output voltage when the  
full-scale setting ranges  
from 0 V (light beam is  
interrupted) to 5 V (light  
beam is fully incident),  
using the Monitor Focus  
function.  
Vertical direction  
Horizontal direction  
Displacement  
Vertical direction  
Horizontal direction  
Magnetic  
Displacement  
Contact  
The graph depicts the correlation between  
transverse deviation and output voltage when  
the full-scale setting ranges from 0 V (light  
beam is interrupted) to 5 V (light beam is fully  
incident), using the Monitor Focus function.  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
0
4
2
0.079  
0
2
0.079  
4
0.157  
10  
0.394  
5
0.197  
0
5
10  
0.394  
Right (Down)  
–10  
–5  
0
5
0.197  
10  
0.394  
0.157  
0.197  
–0.394 –0.197  
Digital Panel  
Controller  
(Up) Left  
Center  
Deviation ℓ (mm in)  
Right (Down)  
(Up) Left  
Center  
Screeing edge position ℓ (mm in)  
Deviation ℓ (mm in)  
Other  
Products  
HL-T1010A HL-T1010F  
HL-T1  
LD  
Correlation between transverse  
deviation and output voltage  
Correlation between interrupted  
beam width and output voltage  
8
8
250 mm 9.843 in  
Sensing object  
Horizontal direction  
500 mm 19.685 in  
Vertical direction  
LA  
500 mm 19.685 in  
+
Receiver  
Receiver  
Emitter  
Receiver  
Emitter  
Emitter  
6
4
2
6
4
2
0
500 mm 19.685 in  
Vertical direction  
Horizontal direction  
The graph depicts the correlation  
between transverse deviation  
and output voltage when the  
full-scale setting ranges from 0 V  
(light beam is interrupted) to 5 V  
(light beam is fully incident),  
using the Monitor Focus function.  
0
10  
0.394  
5
0.197  
0
5
10  
0.394  
Right (Down)  
–10  
–5  
0
5
0.197  
10  
0.394  
0.197  
–0.394 –0.197  
(Up) Left  
Center  
Deviation ℓ (mm in)  
Screeing edge position ℓ (mm in)  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1118  
PRECAUTIONS FOR PROPER USE  
FIBER  
Refer to p.1595 for general precautions and p.1593~ for information about laser beam.  
SENSORS  
LASER  
SENSORS  
Functions  
• This catalog is a guide to select a suitable product. Be  
sure to read instruction manual attached to the product  
prior to its use.  
PHOTO-  
ELECTRIC  
SENSORS  
Function  
Details  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
The following tasks can be done by executing zero  
reset.  
• The display value can be set at “0”.  
• The linear output when the display reads “0” is  
made the center output value of the 2 points set  
by monitor focus. (In the default state, the current  
output is 12 mA and the voltage output is 0 V.)  
AREA  
• Never use this product as a sensing device  
for personnel protection.  
• In case of using sensing devices for  
personnel protection, use products which  
meet laws and standards, such as OSHA,  
ANSI or IEC etc., for personnel protection  
applicable in each region or country.  
Zero reset  
function  
SENSORS  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
The auto scaling function selects whether to display  
the laser beam reception amount in the main-digital  
display in “mm” units or in “%” units, and determines  
whether the amount of laser beam received or the  
amount of laser beam interrupted is displayed. With  
the set standard laser beam reception amount as the  
reference value, the current laser beam reception  
amount (laser beam interrupted amount) is scaled  
automatically and is displayed as well as being  
output.  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Auto scaling  
function  
PARTICULAR  
USE  
SENSORS  
This product is classified as a Class 1 Laser  
Product in IEC / JIS regulations and a Class  
II Laser Product in FDA regulations. Do not  
look at the laser beam through optical  
system such as a lens.  
• The following label is attached to the  
product. Handle the product according to the  
instruction given on the warning label.  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
This function registers and stores the current laser  
beam reception amount in memory as the standard  
laser beam reception amount. The laser beam  
reception amount during full laser beam entry  
becomes the 100 % laser beam reception amount’s  
full scale (F.S.). If this function is used, the display  
and the linear output are set on the full scale (F.S.)  
automatically. It can also be used to correct the laser  
beam reception amount when there is a change in  
the laser beam reception amount due to dirt, etc. on  
the front glass.  
WIRE-SAVING  
SYSTEMS  
Standard  
received light  
setting  
MEASURE-  
MENT  
SENSORS  
The English warning label based  
on FDA regulations is pasted on  
the FDA conformed type.  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
The scaling function is a function that changes the  
display value to the desired amount with respect to  
the setting value. At the desired distance, the display  
value can be input and changed.  
PLC  
Safety standards for laser beam products  
Scaling function  
HUMAN  
• A laser beam can harm human being’s eyes, skin, etc.,  
because of its high energy density. IEC has classified  
laser products according to the degree of hazard and the  
stipulated safety requirements.  
MACHINE  
INTERFACES  
Hysteresis width  
setting function  
This function sets the hysteresis to the desired value.  
ENERGY  
MANAGEMENT  
SOLUTIONS  
With this function, the linear output range and  
inclination, etc. with respect to the display value can  
be specified. Setting is done by determining the 2  
output values with respect to the desired display  
values.  
The HL-T1 series is classified as Class 1 laser.  
FA  
Monitor focus  
function  
COMPONENTS  
Classification by IEC 60825-1  
MACHINE  
VISION  
SYSTEMS  
This function makes the amount of change in the  
measured value an output value. Use this function  
when measuring if you are paying attention to  
changes in measured values, as when counting the  
number of workpieces, etc.  
Classification  
Description  
UV  
CURING  
SYSTEMS  
Differential  
function  
Lasers that are safe under reasonably foreseeable conditions of operation,  
including the use of optical instruments for intrabeam viewing.  
Class 1  
The digital display’s direction can be selected. The  
forward direction or the reverse direction to match  
the direction of installation on the equipment can be  
selected.  
Display reverse  
function  
Safe use of laser products  
Selection  
Guide  
• For the purpose of preventing users from suffering  
injuries by laser products, IEC 60825-1 “Safety of laser  
products”. Kindly check the standards before use.  
(Refer to p.1593~ for information about laser beam.)  
Laser  
Displacement  
ECO display  
function  
This function makes the display dark and saves  
electric power.  
Magnetic  
Displacement  
Contact  
This determines the number of display digits in the  
main-digital and sub-digital displays. If the number of  
digits is limited, the digits are turned off beginning  
with the lowest order digit.  
Displacement  
Display digits  
limitation function  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
This selects whether or not to save the zero reset  
level in memory when the power is turned OFF. If  
you desire to reproduce the zero reset level from the  
previous operating session when you turn the power  
ON again, then enable this function. If this function is  
enabled, the zero reset level data are written into the  
EEPROM each time.  
Digital Panel  
Controller  
Other  
Products  
Zero reset memory  
function  
HL-T1  
LD  
The controller’s key input can be disabled. Once the  
key input is disabled, the controller will not accept  
any key inputs until the key lock is released. Use this  
function to avoid changing the setting by mistake.  
Key lock  
function  
LA  
Connection  
This product is made to satisfy the specifications when the  
sensor head is combined with the controller. In any other  
combination, not only may it not satisfy the specifications,  
but could be the cause of breakdown. So by all means,  
use it so that there is a combination of the sensor head  
and the controller.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1119  
FIBER  
PRECAUTIONS FOR PROPER USE  
Refer to p.1595 for general precautions and p.1593~ for information about laser beam.  
SENSORS  
LASER  
Functional description  
SENSORS  
⑨ ⑪  
PHOTO-  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
/
SAFETY  
COMPONENTS  
PRESSURE /  
FLOW  
Function  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
Description  
PARTICULAR  
USE  
Laser emitting indicator  
(LD ON)  
SENSORS  
Lights up when the sensor head is emitting laser beam.  
(Green LED)  
SENSOR  
OPTIONS  
HIGH: Orange LED (lights up when measured value HIGH threshold value)  
PASS: Green LED (lights up when HIGH threshold value measured value LOW threshold value)  
LOW: Yellow LED (lights up when LOW threshold value measured value)  
Judgment output indicators  
(HIGH / PASS / LOW)  
(Orange / Green / Yellow LED)  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
When in the RUN mode, it displays the measured value (mm/%).  
During measurement hold, it displays the hold value (mm/%).  
In Reverse mode, the top and bottom are displayed in reverse.  
Main digital display  
(5 digit red LED)  
MEASURE-  
MENT  
SENSORS  
When in the RUN mode, it displays the threshold value, voltage / current value, light reception  
amount or resolution. When in the THR mode, it displays the respective threshold values. In  
reverse mode, the top and bottom are displayed in reverse.  
STATIC  
CONTROL  
DEVICES  
Sub-digital display  
(5 digit yellow LED)  
LASER  
MARKERS  
Enable indicator  
(ENABLE)  
Lights up when operation is normal. Goes off when operation is abnormal  
(if the sensor head is not connected when the power is turned on).  
(Green LED)  
PLC  
Zero reset indicator  
(ZERO)  
(Green LED)  
HUMAN  
MACHINE  
Lights up when the zero reset function is enabled.  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
The following 3 modes can be selected.  
RUN mode: Measuring mode  
THR mode: The threshold values are set in this mode.  
FUN mode: Each of the settings are set in this mode.  
Mode selection switch  
FA  
COMPONENTS  
MACHINE  
VISION  
Threshold value select  
switch  
When in the THR / RUN mode, this switches the set threshold value (HIGH / LOW).  
SYSTEMS  
UV  
CURING  
RUN mode: Timing input  
THR mode: Changes the threshold value (forward direction)  
FUN mode: Changes the function setting value (forward direction)  
UP key  
SYSTEMS  
RUN mode: Press for 3 sec. or more: Standard light reception amount setting input  
THR mode: Changes the threshold value (reverse direction)  
DOWN key  
RIGHT key  
LEFT key  
FUN mode: Changes the function setting value (reverse direction)  
Selection  
Guide  
RUN mode: Changes the contents of the sub-digital display (forward direction)  
THR mode: Changes the threshold value digit (forward direction)  
FUN mode: Sets function selection (forward direction)  
Laser  
Displacement  
Magnetic  
Displacement  
RUN mode: Changes the contents of the sub-digital display (reverse direction)  
THR mode: Changes the threshold value digit (reverse direction)  
FUN mode: Sets function selection (reverse direction)  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
RUN mode: Pressing for 1 sec. or more, executes zero reset. Pressing together with the RIGHT  
key for 3 sec. or more, cancels zero reset.  
ENT key  
Digital Panel  
Controller  
THR mode: When threshold value is blinking, the threshold value is set. When the threshold  
value lights up, teaching is executed.  
Other  
Products  
FUN mode: When the set value is blinking, the value is set.  
When the setting is being initialized, pressing for a long time executes initialization.  
HL-T1  
LD  
Others  
• This product outputs the judgment of the laser light analog  
quantity. Since there is variation in the light intensity between  
the center and the edges of the detection area, and the  
emitter side and the receiver side, the “display value” does  
not equal “the actual dimensions”, so caution is necessary.  
Use the displayed dimensional value as a criterion.  
LA  
• If the object being measured has a mirror surface or is  
a transparent body, it may be impossible to measure it  
accurately, so please exercise caution.  
• Absolutely do not attempt to disassemble this product.  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1120  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data can be downloaded from our website.  
Sensor head  
SENSORS  
LASER  
SENSORS  
HL-T1001A(F) HL-T1005A(F)  
PHOTO-  
ELECTRIC  
SENSORS  
2-ø3.2 ø0.126  
2-ø3.2 ø0.126  
ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black)  
Manufactured by  
2.8  
0.110  
34  
1.339  
MICRO  
ø2.6 ø0.102 cable,  
0.2 0.008  
PHOTO-  
ELECTRIC  
SENSORS  
19  
0.748  
0.5 m 1.640 ft long (Gray)  
16  
0.630  
(1.5) (0.059)  
J.S.T. Mfg. Co., Ltd.  
XARR-04VF*  
2.8  
0.110  
5 0.197  
9
AREA  
15  
9
0.354 0.591  
SENSORS  
15  
SAFETY LIGHT  
0.591 0.354  
CURTAINS  
SAFETY  
/
Manufactured by  
J.S.T. Mfg. Co., Ltd.  
XARR-04VF*  
(36.5)  
(1.437)  
COMPONENTS  
(6.9)  
(0.272)  
*
The sensor heads that were produced before January 2006 use the connector shown below.  
Please note that the new connector and previous connector are incompatible.  
PRESSURE /  
FLOW  
Certification / identification label (Note 1)  
SENSORS  
(50 µm 1.969 mil polyester film)  
INDUCTIVE  
PROXIMITY  
SENSORS  
(10)  
(0.394)  
Manufactured by Molex  
51029-0410  
Light beam shielding plate (Note 1)  
PARTICULAR  
USE  
Emission indicator (Green)  
SENSORS  
Beam axis (Note 2)  
15  
0.591  
SENSOR  
OPTIONS  
15  
0.591  
SIMPLE  
Emitter  
WIRE-SAVING  
UNITS  
Receiver  
Notes: 1) IEC / JIS conforming products do not contain light beam shielding plate,  
or certification / identification label.  
WIRE-SAVING  
SYSTEMS  
2) The receiver of HL-T1001A(F) does not incorporate a slit.  
MEASURE-  
MENT  
SENSORS  
Sensor head  
HL-T1010A HL-T1010F  
STATIC  
CONTROL  
DEVICES  
2-ø3.2 ø0.126  
2-ø3.2 ø0.126  
LASER  
ø2.6 ø0.102 cable, 0.5 m 1.640 ft long (Black)  
42  
1.654  
2.8  
0.110  
0.2  
0.008  
MARKERS  
ø2.6 ø0.102 cable,  
25  
0.984  
2.8  
0.110  
Manufactured by  
J.S.T. Mfg. Co., Ltd.  
XARR-04VF*  
0.5 m 1.640 ft long (Gray)  
10  
0.394  
(6.9)(0.272)  
PLC  
14  
0.551  
20  
0.787  
14  
0.551  
20  
0.787  
HUMAN  
MACHINE  
INTERFACES  
Manufactured by  
J.S.T. Mfg. Co., Ltd.  
XARR-04VF*  
22  
0.866  
ENERGY  
(36.5)  
(1.437)  
(1.5)  
(0.059)  
* The sensor heads that were produced before January 2006 use the connector shown below.  
Please note that the new connector and previous connector are incompatible.  
MANAGEMENT  
SOLUTIONS  
Certification / identification label (Note)  
(50 μm 1.969 mil polyester film)  
FA  
COMPONENTS  
(10)  
(0.394)  
Manufactured by Molex  
51029-0410  
MACHINE  
VISION  
SYSTEMS  
Light beam shielding plate (Note)  
Emission indicator  
)
(
Green  
Beam axis  
UV  
CURING  
SYSTEMS  
20  
0.787  
20  
0.787  
Emitter  
Receiver  
Selection  
Guide  
Note: IEC / JIS conforming products do not contain light beam shielding  
Laser  
plate, or certification/identification label.  
Displacement  
Magnetic  
Displacement  
Controller  
Calculation unit (Optional)  
HL-AC1 HL-AC1P  
HL-AC1-CL  
Contact  
Displacement  
Collimated  
Beam  
Mounting drawing with a mounting bracket MS-HLAC1-1 (Optional)  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Connector for calculation unit  
connection (on each side)  
Linking connector  
24.9  
Digital Panel  
Controller  
0.980  
32.2 1.268  
30 1.181  
(3.6)  
64.3  
Other  
Products  
(0.142)  
2.531  
Connection indicator (Orange)  
4.3  
34.3  
0.169  
1.350  
15.1  
0.594  
HL-T1  
LD  
15.8  
13.2  
0.622  
0.520  
57 2.244  
54.9 2.161  
12 0.472  
8 0.315  
22.4  
16  
ø5.2 ø0.205 cable,  
2 m 6.562 ft long  
3.9  
LA  
0.882  
0.630  
0.154  
13  
36.8  
30  
26  
Suitable for 35 mm 1.378 in  
width DIN rail  
0.512  
2-ø3.2 ø0.126  
1.449  
1.181  
1.024  
5.4  
36.7  
5
150 5.906 approx.  
0.213  
3.4  
1.445  
0.197  
03.1.344  
3.4 0.134  
0.134  
ø5.1 ø0.201 cable  
Suitable for 35 mm 1.378 in  
width DIN rail  
32.2  
1.268  
16.1  
0.634  
Connector for  
sensor head connection  
5.4 0.213  
22.4 16  
0.882 0.630  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1121  
FIBER  
DIMENSIONS (Unit: mm in)  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Sensor head mounting bracket for HL-T1001A(F) / HL-T1005A(F) [Accessory for HL-T1001A(F) / HL-T1005A(F)]  
MS-HLT1-1  
PHOTO-  
ELECTRIC  
SENSORS  
Assembly dimensions  
3.4  
0.134  
15  
1
2
0.591  
6
7
5
1.1  
9
MICRO  
PHOTO-  
Mounting drawing with HL-T1005A’s receiver  
0.236  
0.276 0.197  
9
ø3.2 ø0.126  
0.043  
0.354  
ELECTRIC  
SENSORS  
0.354  
AREA  
3.2 0.126  
9
SENSORS  
0.354  
3.4  
2-M3  
×
0.5 0.020  
t 1.6  
SAFETY LIGHT  
5
0.134  
12.5  
3.2  
CURTAINS  
/
14.5  
(34.6)  
0.197  
0.492  
SAFETY  
0.126  
0.571  
1.6 0.063  
3.4 0.134  
(1.362)  
COMPONENTS  
5 0.197  
5 0.197  
PRESSURE /  
FLOW  
9
0.354  
10  
t 0.063  
SENSORS  
13.1  
0.516  
9
0.394  
3 0.118  
INDUCTIVE  
PROXIMITY  
SENSORS  
1.1  
3.4 0.134  
1.6 0.063  
0.043  
0.354  
2-ø3.2 ø0.126  
1.1 0.043  
5
9 0.354  
0.197  
PARTICULAR  
USE  
5
5 0.197  
0.197  
SENSORS  
3.4 0.134  
9
5
SENSOR  
OPTIONS  
17  
0.669  
t 1.2  
3.2  
0.354  
17  
t 0.047  
0.126  
7
0.669  
0.374  
9.5  
0.276  
SIMPLE  
WIRE-SAVING  
UNITS  
5
17  
17  
13.1  
ø3.2 ø0.126  
0.197  
0.669  
0.197  
t 1.2  
t 0.047  
0.669  
0.516  
3.4  
24.5  
WIRE-SAVING  
SYSTEMS  
0.134  
0.965  
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)  
MEASURE-  
MENT  
Two M3 (length 20 mm 0.787 in) screws with washers are attached.  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Sensor head mounting bracket for HL-T1010A(F) [Accessory for HL-T1010A(F)  
]
MS-LA3-1  
LASER  
MARKERS  
Assembly dimensions  
1
2
Mounting drawing with HL-T1010A’s receiver  
20  
0.787  
14  
20  
PLC  
0.787  
14  
2-ø3.2 ø0.126  
6
2-ø3.2 ø0.126  
0.236  
HUMAN  
MACHINE  
0.551  
0.551  
2.6  
INTERFACES  
6 0.236  
13  
0.102  
0.512  
ENERGY  
MANAGEMENT  
SOLUTIONS  
3.4  
2-M3 × 0.5 0.020  
14  
0.134  
0.551  
16  
(45.1)  
23  
0.630  
(1.776)  
0.906  
FA  
2.6  
3.4  
COMPONENTS  
0.102  
0.134  
t 1.6  
t 0.063  
14  
0.551  
2.6 0.102  
MACHINE  
VISION  
3
14  
10  
0.118  
2-ø3.2 ø0.126  
0.551  
SYSTEMS  
0.394  
3 0.118  
2.6 0.102  
3.4 0.134  
UV  
CURING  
3.4  
3.4 0.134  
0.134  
SYSTEMS  
2.6 0.102  
3
14  
0.118  
0.551  
14  
23  
0.906  
3.4  
10  
0.551  
0.134  
13  
0.394  
2.6  
0.102  
0.512  
6 0.236  
23  
10  
0.394  
23  
0.906  
Selection  
Guide  
t 1.6  
t 0.063  
0.906  
13  
0.512  
Laser  
Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated)  
Displacement  
Magnetic  
Two M3 (length 25 mm 0.984 in) screws with washers are attached.  
23  
20  
0.787  
Displacement  
0.906  
t 1.6  
t 0.063  
Contact  
33  
Displacement  
1.229  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Controller mounting bracket (Optional)  
Sensor head to controller connection cable (Accessory for sensor head)  
MS-HLAC1-1  
CN-HLT1-1  
Digital Panel  
Controller  
+200  
0
34.8  
Other  
Products  
1,500  
59.055  
1.370  
22  
2-ø3.2 ø0.126  
+7.874  
0
46  
1.811  
Gray  
0.866  
16  
3
2.5  
ø15  
ø0.591  
0.118  
0.098  
0.630  
HL-T1  
LD  
Manufactured by Hirose  
7.3  
0.287  
Black  
ø2.6 ø0.102 × 2  
Manufactured by J.S.T. Mfg. Co., Ltd. XAP-04V-1*  
Electric Co.,Ltd. RP17-13P-12PC  
3
3
26.8  
1.055  
16  
0.118  
0.118  
LA  
* The sensor heads that were produced  
before January 2006 use the connector  
shown below.  
0.630  
3.4  
5.4  
5.3  
0.134  
0.213  
0.209  
Please note that the new connector and  
previous connector are incompatible.  
5.4  
0.213  
32.2 27.2  
27.2  
1.268 1.071  
1.071  
3.4  
0.134  
Manufactured by  
Molex 51030-0430  
t 1.0  
t 0.039  
Ultra-compact Laser Collimated Beam Sensor HL-T1 SERIES  
1122  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Side-view attachment for HL-T1001A(F) / HL-T1005A(F) (Optional)  
HL-T1SV1  
PHOTO-  
Assembly dimensions  
ELECTRIC  
SENSORS  
Mounting drawing with HL-T1005A’s receiver  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
2.7  
0.106  
AREA  
15  
15  
SENSORS  
0.591  
0.591  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
(34)  
Beam axis  
(1.339)  
2-ø2.2 ø0.087  
Beam axis  
PRESSURE /  
FLOW  
15  
19  
0.748  
0.591  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
15  
15  
10.6  
0.591  
0.591 0.417  
PARTICULAR  
USE  
7.5  
0.295  
15  
0.591  
12.5  
0.492  
2.2  
SENSORS  
0.087  
SENSOR  
OPTIONS  
Material: Polyetherimide (Enclosure), Glass (Front cover)  
SIMPLE  
WIRE-SAVING  
UNITS  
Two M2 (length 6 mm 0.236 in) screws with washers are attached.  
WIRE-SAVING  
SYSTEMS  
Side-view attachment for HL-T1010A(F) (Optional)  
HL-T1SV2  
MEASURE-  
MENT  
Assembly dimensions  
SENSORS  
STATIC  
Mounting drawing with HL-T1010A’s receiver  
CONTROL  
DEVICES  
LASER  
MARKERS  
20  
2.8  
0.787  
0.110  
PLC  
HUMAN  
(46)  
20  
MACHINE  
INTERFACES  
(1.811)  
0.787  
21  
25  
ENERGY  
MANAGEMENT  
SOLUTIONS  
0.827  
0.984  
Beam axis  
2-ø2.2 ø0.087  
Beam axis  
FA  
COMPONENTS  
20  
20 15.6  
MACHINE  
VISION  
0.787  
0.787 0.614  
SYSTEMS  
UV  
11  
0.433  
21  
0.827  
CURING  
SYSTEMS  
2.2  
21  
0.087  
0.827  
Material: Polyetherimide (Enclosure), Glass (Front cover)  
Two M2 (length 6 mm 0.236 in) screws with washers are attached.  
Selection  
Guide  
Laser  
Displacement  
Magnetic  
Displacement  
Contact  
Displacement  
Collimated  
Beam  
Sensors  
Metal-sheet  
Double-feed  
Detection  
Digital Panel  
Controller  
Other  
Products  
HL-T1  
LD  
LA  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY