HL1-H-AC100-F [PANASONIC]

Electromechanical Relay, SPDT, AC Output,;
HL1-H-AC100-F
型号: HL1-H-AC100-F
厂家: PANASONIC    PANASONIC
描述:

Electromechanical Relay, SPDT, AC Output,

光电二极管
文件: 总10页 (文件大小:2405K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Relay for control panel of  
1c 15 A and 2c 10 A  
HL RELAYS  
FEATURES  
TYPICAL APPLICATIONS  
1. Compact high-capacity control relay  
In the same external dimensions as an  
HC relay, this compact power relay  
enables high-capacity control:  
15 A for 1 Form C, 10 A for 2 Form C.  
2. Designed for high reliability  
High operational reliability is achieved by  
solder-less construction, in which all  
connections between lead wires and the  
contact springs and terminal plate are  
welded.  
1. Factory automation equipment and  
automotive devices  
2. Control panels, power supply  
equipment, molding equipment,  
machine tools, welding equipment,  
agricultural equipment, etc.  
3. Office equipment, automatic  
vending machines,  
telecommunications equipment,  
disaster prevention equipment,  
copiers, measuring devices, medical  
equipment, amusement devices, etc.  
4. All types of household appliance  
3. Various types provided in rich  
lineup. LED indicator and diode type is  
also available.  
4. The terminals are compatible with  
#187 series tab terminals.  
5. Sockets and terminal sockets are  
available.  
ORDERING INFORMATION  
HL  
F
Contact arrangement  
1: 1 Form C  
2: 2 Form C  
Terminal arrangement  
H:  
L:  
Plug-in type  
Plug-in with LED indication  
HP: PC board type  
PL: PC board with LED indication  
HTM: TM type  
Nominal coil voltage  
AC 6, 12, 24, 48, 100 (100/110), 120 (110/120),  
200 (200/220), 240 (220/240) V  
DC 6, 12, 24, 48, 100 (100/110) V  
Contact material  
F: AgSnO2 type  
Notes: Certified by UL and CSA.  
Please inquire about TV approved products.  
*Diode type is available (DC coil plug-in type with LED indication only).  
ds_61C03_en_hl: 180613J  
1
HL  
TYPES  
1. Plug-in type  
2. Plug-in type (with LED indication)  
1 Form C  
2 Form C  
1 Form C  
2 Form C  
Nominal coil  
voltage  
Nominal coil  
voltage  
Part No.  
Part No.  
Part No.  
Part No.  
6V AC  
12V AC  
HL1-H-AC6V-F  
HL1-H-AC12V-F  
HL1-H-AC24V-F  
HL1-H-AC48V-F  
HL1-H-AC100V-F  
HL1-H-AC120V-F  
HL1-H-AC200V-F  
HL1-H-AC240V-F  
HL1-H-DC6V-F  
HL1-H-DC12V-F  
HL1-H-DC24V-F  
HL1-H-DC48V-F  
HL1-H-DC100V-F  
HL2-H-AC6V-F  
HL2-H-AC12V-F  
HL2-H-AC24V-F  
HL2-H-AC48V-F  
HL2-H-AC100V-F  
HL2-H-AC120V-F  
HL2-H-AC200V-F  
HL2-H-AC240V-F  
HL2-H-DC6V-F  
HL2-H-DC12V-F  
HL2-H-DC24V-F  
HL2-H-DC48V-F  
HL2-H-DC100V-F  
6V AC  
12V AC  
HL1-L-AC6V-F  
HL1-L-AC12V-F  
HL1-L-AC24V-F  
HL1-L-AC48V-F  
HL1-L-AC100V-F  
HL1-L-AC120V-F  
HL1-L-AC200V-F  
HL1-L-AC240V-F  
HL1-L-DC6V-F  
HL1-L-DC12V-F  
HL1-L-DC24V-F  
HL1-L-DC48V-F  
HL1-L-DC100V-F  
HL2-L-AC6V-F  
HL2-L-AC12V-F  
HL2-L-AC24V-F  
HL2-L-AC48V-F  
HL2-L-AC100V-F  
HL2-L-AC120V-F  
HL2-L-AC200V-F  
HL2-L-AC240V-F  
HL2-L-DC6V-F  
HL2-L-DC12V-F  
HL2-L-DC24V-F  
HL2-L-DC48V-F  
HL2-L-DC100V-F  
24V AC  
24V AC  
48V AC  
48V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
6V DC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
6V DC  
12V DC  
12V DC  
24V DC  
24V DC  
48V DC  
48V DC  
100/110V DC  
100/110V DC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
3. Plug-in type (with LED indication and diode)  
4. PC board type  
1 Form C  
2 Form C  
1 Form C  
2 Form C  
Nominal coil  
voltage  
Nominal coil  
voltage  
Part No.  
Part No.  
Part No.  
Part No.  
6V AC  
12V AC  
HL1-L-DC6V-D-F  
HL1-L-DC12V-D-F  
HL1-L-DC24V-D-F  
HL1-L-DC48V-D-F  
HL1-L-DC100V-D-F  
HL2-L-DC6V-D-F  
HL2-L-DC12V-D-F  
HL2-L-DC24V-D-F  
HL2-L-DC48V-D-F  
HL2-L-DC100V-D-F  
6V AC  
12V AC  
HL1-HP-AC6V-F  
HL1-HP-AC12V-F  
HL1-HP-AC24V-F  
HL1-HP-AC48V-F  
HL1-HP-AC100V-F  
HL1-HP-AC120V-F  
HL1-HP-AC200V-F  
HL1-HP-AC240V-F  
HL1-HP-DC6V-F  
HL1-HP-DC12V-F  
HL1-HP-DC24V-F  
HL1-HP-DC48V-F  
HL1-HP-DC100V-F  
HL2-HP-AC6V-F  
HL2-HP-AC12V-F  
HL2-HP-AC24V-F  
HL2-HP-AC48V-F  
HL2-HP-AC100V-F  
HL2-HP-AC120V-F  
HL2-HP-AC200V-F  
HL2-HP-AC240V-F  
HL2-HP-DC6V-F  
HL2-HP-DC12V-F  
HL2-HP-DC24V-F  
HL2-HP-DC48V-F  
HL2-HP-DC100V-F  
24V AC  
24V AC  
48V AC  
48V AC  
100/110V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
6V DC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
12V DC  
24V DC  
48V DC  
100/110V DC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
5. PC board type  
6. TM type  
1 Form C  
2 Form C  
1 Form C  
2 Form C  
Nominal coil  
voltage  
Nominal coil  
voltage  
Part No.  
Part No.  
Part No.  
Part No.  
6V AC  
12V AC  
HL1-HP-AC6V-F  
HL1-HP-AC12V-F  
HL1-HP-AC24V-F  
HL1-HP-AC48V-F  
HL1-HP-AC100V-F  
HL1-HP-AC120V-F  
HL1-HP-AC200V-F  
HL1-HP-AC240V-F  
HL1-HP-DC6V-F  
HL1-HP-DC12V-F  
HL1-HP-DC24V-F  
HL1-HP-DC48V-F  
HL1-HP-DC100V-F  
HL2-HP-AC6V-F  
HL2-HP-AC12V-F  
HL2-HP-AC24V-F  
HL2-HP-AC48V-F  
HL2-HP-AC100V-F  
HL2-HP-AC120V-F  
HL2-HP-AC200V-F  
HL2-HP-AC240V-F  
HL2-HP-DC6V-F  
HL2-HP-DC12V-F  
HL2-HP-DC24V-F  
HL2-HP-DC48V-F  
HL2-HP-DC100V-F  
6V AC  
12V AC  
HL1-HTM-AC6V-F  
HL1-HTM-AC12V-F  
HL1-HTM-AC24V-F  
HL1-HTM-AC48V-F  
HL1-HTM-AC100V-F  
HL1-HTM-AC120V-F  
HL1-HTM-AC200V-F  
HL1-HTM-AC240V-F  
HL1-HTM-DC6V-F  
HL1-HTM-DC12V-F  
HL1-HTM-DC24V-F  
HL1-HTM-DC48V-F  
HL1-HTM-DC100V-F  
HL2-HTM-AC6V-F  
HL2-HTM-AC12V-F  
HL2-HTM-AC24V-F  
HL2-HTM-AC48V-F  
HL2-HTM-AC100V-F  
HL2-HTM-AC120V-F  
HL2-HTM-AC200V-F  
HL2-HTM-AC240V-F  
HL2-HTM-DC6V-F  
HL2-HTM-DC12V-F  
HL2-HTM-DC24V-F  
HL2-HTM-DC48V-F  
HL2-HTM-DC100V-F  
24V AC  
24V AC  
48V AC  
48V AC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
6V DC  
100/110V AC  
110/120V AC  
200/220V AC  
220/240V AC  
6V DC  
12V DC  
12V DC  
24V DC  
24V DC  
48V DC  
48V DC  
100/110V DC  
100/110V DC  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
For sockets and terminal sockets, see page 8.  
ds_61C03_en_hl: 180613J  
2
HL  
RATING  
1. Coil data  
1) AC coils  
Nominal coil current  
(mA)  
Nominal operating power  
(VA)  
Inductance (H)  
Nominal coil  
voltage  
Pick-up voltage  
(at 20C 68F)  
Drop-out voltage  
(at 20C 68F)  
Max. applied  
voltage  
50Hz  
224  
60Hz  
200  
50Hz  
60Hz  
When drop-out When operating  
6V AC  
12V AC  
0.078  
0.312  
1.243  
4.974  
23.75  
27.19  
85.98  
0.074  
0.295  
1.181  
4.145  
20.63  
25.57  
81.76  
111  
100  
24V AC  
56  
50  
80%V or less of  
nominal voltage  
(Initial)  
30%V or more of  
nominal voltage  
(Initial)  
110%V of  
nominal voltage  
48V AC  
28  
25  
1.3  
1.2  
100/110V AC  
110/120V AC  
200/220V AC  
13.4/14.7  
12.2/13.5  
6.7/7.4  
12/13.2  
10.9/11.9  
6/6.6  
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage.  
In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly  
to coil burnout.  
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.  
(This value differs depending on the ambient temperature. Please contact us for details.)  
2) DC coils (at 20C 68F)  
Nominal coil  
voltage  
Nominal coil current  
(mA)  
Nominal operating  
power (W)  
Coil resistance  
Pick-up voltage  
(at 20C 68F)  
Drop-out voltage  
(at 20C 68F)  
Max. applied voltage  
(at 70C 158F)  
()  
6V DC  
12V DC  
150  
75  
0.9  
0.9  
0.9  
0.9  
1.0  
40  
160  
80%V or less of  
nominal voltage  
(Initial)  
10%V or more of  
nominal voltage  
(Initial)  
110%V of  
nominal voltage  
24V DC  
37  
650  
48V DC  
18.5  
10  
2,600  
10,000  
100/110V DC  
Notes: 1. The rated excitation current is 10% (20C 68F).  
2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature.  
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the  
rated voltage.  
4. For use with 200 V DC, connect a 10 K(5W) resistor, in series, to the 100 V DC relay.  
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.  
(This value differs depending on the ambient temperature. Please contact us for details.)  
2. Specifications  
Characteristics  
Item  
Initial contact resistance, max  
Contact material  
Specifications  
Max. 50 m(By voltage drop 6 V DC 1A)  
AgSnO2 type  
Contact  
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)  
2 Form C: 10A 125V AC (resistive load)  
Nominal switching capacity  
Rating  
Min. switching capacity (Reference value)*1  
Insulation resistance (Initial)  
Between open contacts  
100mA 5V DC  
Min. 100M(at 500V DC)  
Measurement at same location as “Initial breakdown voltage” section.  
1,000 Vrms for 1min. (Detection current: 10mA.)  
Breakdown voltage  
Between contact sets  
(Initial)  
1,500 Vrms for 1min. (Detection current: 10mA.)  
Electrical  
Between contact and coil  
2,000 Vrms for 1min. (Detection current: 10mA.)  
characteristics  
Temperature rise  
Max. 80C (By resistive method, nominal voltage)  
Operate time (at 20C 68F)*2  
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)  
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)  
(without diode)  
Release time (at 20C 68F)*2  
Functional  
Shock resistance  
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)  
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
Destructive  
Mechanical  
characteristics  
Functional  
Vibration resistance  
Destructive  
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)  
10 to 55 Hz at double amplitude of 2 mm  
Mechanical  
AC type: 5107 (at 180 times/min.), DC type: 108 (at 180 times/min.)  
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 5105  
AC load  
Electrical  
Expected life  
2 Form C: 10A 250V AC resistive load (cos=1) Life switching cycle: Min. 3105  
1 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 5105  
2 Form C: 3A 30V DC resistive load (cos=1) Life switching cycle: Min. 5105  
DC load  
Ambient temperature: –50C to +70C –58F to +158F (Without LED indication);  
Conditions for operation, transport and storage*3 –50C to +60C –58F to +140F (With LED indication)  
Conditions  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
20 times/min. (at max. rating)  
Approx. 35g 1.23 oz  
Max. Operating speed  
Unit weight  
Notes:  
If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature  
between –50C to +40C –58F to +104F (AC type).  
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2 For the AC coil types, the operate/release time will differ depending on the phase.  
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport  
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.  
*4 When using the socket, be sure to verify the max. continuous current.  
ds_61C03_en_hl: 180613J  
3
HL  
REFERENCE DATA  
Switching capacity range (1 Form C)  
Switching capacity range (2 Form C)  
AC resistive load  
AC resistive load  
15  
10  
10  
AC inductive  
load (cosϕ=0.4)  
AC inductive  
load (cosϕ=0.4)  
DC resistive  
load  
DC resistive  
load  
DC inductive  
load (L/R=7ms)  
DC inductive  
load (L/R=7ms)  
1
1
0.1  
0.1  
10  
100  
500 1,000  
10  
100  
500 1,000  
Contact voltage, V  
Contact voltage, V  
With diode type (For DC)  
1. DC coil surge voltage waveform  
(without diode)  
2.Switching capacity range (2 Form C)  
Diode characteristics;  
Reverse breakdown voltage:1,000V  
Forward current: 1A  
ON  
OFF  
ON  
OFF  
260V  
+
To digital  
memory  
12V DC  
+
To digital  
memory  
12V DC  
Reverse breakdown voltage: 1,000 V  
Forward current: 1 A  
(
(
DIMENSIONS(mm inch)  
Download CADData from our Web site.  
1. Plug-in type  
1 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
27.2  
.819  
1.071  
2
3
6
35.4  
7
8
1.394  
1.2  
.047  
6.35  
.250  
LED AC type  
LED DC type  
0.5  
2
6
2
6
.020  
3
3
Compatible with tab terminal  
#187 series receptacle.  
10  
7
7
.394  
8
(+)  
8
()  
(
)
(
)
3.95  
2
6
.156  
4.6  
3
.181  
6
.236  
7.15  
.281  
7
8
14.2  
.559  
General tolerance: 0.3 .012  
ds_61C03_en_hl: 180613J  
4
HL  
2 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
.819  
27.2  
1.071  
1
3
5
2
4
6
7
8
35.4  
1.394  
1.2  
.047  
6.35  
LED AC type  
LED DC type  
.250  
0.5  
1
3
5
2
4
6
1
3
5
2
4
6
.020  
Compatible with tab terminal  
#187 series receptacle.  
7
10  
7
8
(+)  
8
.394  
()  
(
)
(
)
3.7  
1
3
2
.146  
4.7  
4
.185  
6
6
5
.236  
7.3  
.287  
7
8
14.2  
.559  
General tolerance: 0.3 .012  
2. PC board type  
1 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
.819  
27.2  
1.071  
2
3
6
7
8
35.4  
1.394  
LED AC type  
LED DC type  
2
6
2
6
1.2  
.047  
5
3
3
.197  
3.5  
.138  
1.5  
0.5  
.059  
.020  
7
7
8
8
(+)  
(
)
()  
(
)
10  
.394  
3.95  
.156  
4.6  
2
6
3
.181  
6
PC board pattern (Bottom view)  
.236  
5-2 dia. hole  
7.15  
10  
5-.079 dia.  
.281  
R3  
7
8
.394  
R.118  
4.6  
.181  
17.75  
.699  
14.2  
.559  
6
R2  
.236  
8.5  
General tolerance: 0.3 .012  
R.079  
.335  
4
.157  
7.15  
.281  
14.2  
.559  
Tolerance: 0.1 .004  
ds_61C03_en_hl: 180613J  
5
HL  
2 Form C  
External dimensions  
Schematic (Bottom view)  
Standard type  
20.8  
.819  
27.2  
CAD Data  
1.071  
1
3
5
2
4
6
7
8
35.4  
1.394  
LED AC type  
LED DC type  
1
3
5
2
4
6
1
3
5
2
4
6
1.2  
.047  
5
.197  
3.5  
.138  
0.5  
1.5  
7
7
.020  
.059  
8
(+)  
8
()  
(
)
(
)
10  
.394  
3.7  
.146  
4.7  
.185  
6
1
3
2
4
PC board pattern (Bottom view)  
6
5
.236  
8-2 dia. hole  
8-.079 dia.  
10  
7.3  
.394  
.287  
7
8
1.25  
.049  
1.25  
.049  
2
18  
.709  
13.3  
.524  
R2  
.079  
14.2  
.559  
R.079  
1.25  
2
.049  
General tolerance: 0.3 .012  
.079  
4.157  
4
4
R2  
R.079  
7.3  
.287  
14.2  
.559  
Tolerance: 0.1 .004  
3. TM type  
1 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
Standard type  
43  
1.693  
20.6  
.811  
2
2
3
.079  
6
7
8
34.4  
1.354  
Chassis (Panel) cutout  
in tandem mounting  
Chassis (Panel) cutout  
1.2  
23  
.047  
6.35  
.906  
.250  
2-3.2 to 3.5 dia. hole  
2-.126 to .138 dia.  
0.5  
.020  
37.6  
Compatible with tab terminal  
#187 series receptacle.  
1.470  
37.6  
3.6  
1.470  
.142  
21  
21  
.827  
.827  
2
.079  
3.95  
.156  
4.6  
Tolerance: 0.1 .004  
2
3
.181  
6
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston  
#187 series or #187 tab terminals conforming to UL or CSA  
inch-standard dimensions.  
6
37.6  
.236  
1.480  
7.15  
.281  
7
8
2. In mounting, use M3 screws and M3 washers.  
3. When mounting TM types, use washers to prevent damage  
or distortion to the polycarbonate cover.  
4. When tightening fixing screws, the optimum torque range  
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use  
washers to prevent loosening.  
General tolerance: 0.3 .012  
ds_61C03_en_hl: 180613J  
6
HL  
2 Form C  
CAD Data  
External dimensions  
Schematic (Bottom view)  
Standard type  
43  
1.693  
20.6  
.811  
1
3
5
2
4
6
2
.079  
7
8
34.4  
1.354  
Chassis (Panel) cutout  
in tandem mounting  
Chassis (Panel) cutout  
1.2  
.047  
6.35  
23  
.250  
.906  
2-3.2 to 3.5 dia. hole  
2-.126 to .138 dia.  
0.5  
.020  
Compatible with tab terminal  
#187 series receptacle.  
37.6  
1.470  
3.6  
37.6  
.142  
1.470  
21  
21  
.827  
.827  
2
.079  
3.7  
.146  
4.7  
.185  
6
1
3
2
4
6
Tolerance: 0.1 .004  
Notes: 1. If connecting to #187 series tab terminals, use AMP Faston  
#187 series or #187 tab terminals conforming to UL or CSA  
inch-standard dimensions.  
37.6  
5
.236  
1.480  
7.3  
.287  
7
8
2. In mounting, use M3 screws and M3 washers.  
3. When mounting TM types, use washers to prevent damage  
or distortion to the polycarbonate cover.  
4. When tightening fixing screws, the optimum torque range  
should be 0.294 to 0.49 N·m, (3 to 5 kgf·cm). Moreover, use  
washers to prevent loosening.  
General tolerance: 0.3 .012  
SAFETY STANDARDS  
1. Standard type (Plug-in type except with diode, PC board type, TM type)  
UL/C-UL (Recognized)  
File No. Contact rating  
CSA (Certified)  
Contact rating  
TV rating (UL/CSA)  
TÜV rating  
Contact rating  
15A 125V AC(cos=1.0)  
Contact  
arrangement  
File No.  
File No.  
Rating  
File No.  
B1304  
UL: E43149  
CSA:  
LR26550  
etc.  
E43028  
E43028  
15A 250V AC  
LR26550  
etc.  
10A 125, 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
NOTV-5  
NCTV-2  
13461 340 10A 250V AC(cos=1.0)  
1 Form C  
2 Form C  
1/3HP 125, 250V AC  
10A 30V DC  
10A 30V=(L/R=0ms)  
UL: E43149  
CSA:  
LR26550  
etc.  
B1304  
10A 250V(cos=1.0)  
13461 340 10A 30V=(L/R=0ms)  
10A 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
LR26550  
etc.  
10A 125, 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
NOTV-4  
NCTV-2  
2. Plug-in type (with diode)*2  
UL/C-UL (Recognized)  
CSA (Certified)  
Contact rating  
TV rating (UL/CSA)  
VDE (Certified)  
Contact  
arrangement  
File No.  
Contact rating  
File No.  
File No.  
Rating  
File No.  
B1304  
Contact rating  
15A 125V(cos=1.0)  
E43028*1  
15A 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
10A 125, 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
13461 340 10A 250V(cos=1.0)  
1 Form C  
2 Form C  
10A 30V=(L/R=0ms)  
B1304  
E43028*2  
10A 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
10A 125, 250V AC  
1/3HP 125, 250V AC  
10A 30V DC  
10A 250V(cos=1.0)  
13461 340  
10A 30V=(L/R=0ms)  
*1 Indicates the UL/C-UL recognition file number.  
*2 DC coil plug-in type with LED indication only.  
For Cautions for Use, see Relay Technical Information.  
ds_61C03_en_hl: 180613J  
7
HL RELAYS  
(Sockets and DIN rail  
terminal socket)  
ACCESSORIES  
FEATURES  
1. HL relay connection accessories  
include plug-in sockets, PC board  
sockets, and terminal socket for DIN  
rails.  
3. A hold-down clip is included in the  
package.  
The fixing method is the  
same as for HL sockets,  
HC sockets and ordinary  
HC terminal sockets.  
2. Certified by UL and CSA  
HC/HL-LEAF-SPRING-MK  
TYPES  
1. Sockets  
Type  
No. of poles  
Item  
HL1 socket  
Part No.  
HL1-SS-K  
HL2-SS-K  
HL1-PS-K  
HL2-PS-K  
1-pole  
2-pole  
1-pole  
2-pole  
Plug-in socket  
HL2 socket  
HL1 PC board socket  
HL2 PC board socket  
PC board socket  
Standard packing: Carton: 20 pcs.; Case: 200 pcs.  
2. Terminal sockets  
Type  
No. of poles  
Item  
HK2-DIN rail terminal socket  
HK2-DIN rail terminal socket (Finger protect type)  
Part No.  
AHKA21  
DIN rail terminal socket  
1/2-pole (common)  
AHKA21P  
Standard packing: Carton: 10 pcs.; Case: 100 pcs.  
RATING  
Specifications (Sockets and DIN rail terminal sockets)  
Item  
Performance  
HK2-DIN rail  
HL1  
Plug-in socket  
HL1  
HL2  
Plug-in socket  
HL2  
HK2-DIN rail  
terminal socket  
terminal socket  
(Finger protect  
type)  
Type  
PC board socket  
PC board socket  
Contact arrangement  
1 Form C (1-pole)  
2 Form C (2-pole)  
2 Form C (1/2-pole common)  
Max. continuous current  
(Ambient temperature:  
10A  
10A  
10A  
10A  
15A 15A  
-50 to +70C -58 to +158F)  
Between open contacts  
Breakdown  
voltage  
Between contact sets  
2, 000 Vrms for 1 min. (Detection current: 10mA)  
(Initial)  
Between contact and coil  
Initial insulation resistance  
100 Mbetween each terminal (500V DC)  
Note: When using a 1-pole HL relay on 1 Form C socket (HL1 Plug-in and HL1 PC board), please use within a range that does not exceed the max. continuous current (10A).  
ds_61C03_en_hl: 080413J  
8
HL  
DIMENSIONS (Unit: mm inch)  
1. Plug-in type sockets  
HL1 socket/External dimensions  
Hold-down clip  
Compatible with tab  
terminal #187 series  
receptacle.  
25.5  
Note: The external and mounting  
dimensions of HL2 socket  
are the same for HL1 socket  
types. Only the number of  
terminals varies.  
1.004  
29.4  
1.157  
HL1 Socket (HL1-SS-K)  
11.2  
.441  
18.7  
.736  
Hold-down clip is packaged with the socket.  
(Applied to HC sockets and ordinary  
HC terminal sockets)  
General tolerance: 0.3 .012  
HL2 Socket (HL2-SS-K)  
Mounting hole diagram  
Side-by-side installation  
25.8  
1.016  
8.9  
.350  
Notes: 1. Applicable chassis board thickness is 1.0 to  
2.0 mm.  
25.8  
1.016  
2. Installation is easy by inserting the socket  
from the top into the holes and by  
depressing the two down arrows on the  
retention fitting from the front.  
5.9  
.232  
21.6  
.850  
21.6  
.850  
Tolerance: 0.1 .004  
2. PC board type sockets  
HL2 PC board type socket  
External dimensions  
Hold-down clip  
21.2  
.835  
Note: The external and mounting  
dimensions of HL2 PC  
board type socket are the  
same for HL1 PC board type  
socket. Only the number of  
terminals varies.  
29.4  
1.157  
2.0  
HL1 PC board type socket  
(HL1-PS-K)  
.079  
1.0  
11.2  
.441  
.039  
16.2  
.638  
Hold-down clip is packaged with the socket.  
(Applied to HC sockets and ordinary  
HC terminal sockets)  
General tolerance: 0.3 .012  
HL2 PC board type socket  
(HL2-PS-K)  
PC board pattern (Bottom view)  
Side-by-side installation (For 2 Form C)  
10  
13.2  
.913  
10  
.394  
.394  
1 Form C  
2 Form C  
2.4 dia. hole  
.094 dia.  
10  
.394  
17.45  
.687  
4.7  
17.45  
.185  
12.75  
.502  
17.45  
.687  
.687  
(6.6)  
(.260)  
6.75  
.266  
17.25  
.679  
10  
6.75  
.266  
(5.3)  
(.209)  
.394  
15.3  
.602  
15.3  
.602  
Tolerance: 0.1 .004  
17.45  
.687  
15.3  
.602  
2.4 dia. hole  
.094 dia.  
7.9  
.311  
15.3  
.602  
Tolerance: 0.1 .004  
ds_61C03_en_hl: 080413J  
9
HL  
3. HK2-DIN rail terminal socket  
(AHKA21)  
External dimensions  
Schematic  
Mounting hole dimensions  
7
2
1
2-4.5 dia.  
.276  
2-4.5x6 2-.177x6  
mounting holes  
Max. 30  
2-.177 dia.  
M3.5 .138  
terminal screw  
Max. 1.181  
3.4  
.134  
4
3
68±0.3  
2.677±.012  
Max. 78.5  
35.4  
1.394  
Max. 3.091  
6
8
5
7
19±0.2  
.748±.008  
Max. 28.5  
8
.315  
General tolerance: 0.5 .020  
Max. 1.122  
4. HK2-DIN rail terminal socket (Finger protect type)  
(AHKA21P)  
External dimensions  
Schematic  
Mounting hole dimensions  
7
2
1
2-4.5 dia.  
Max. 33  
.276  
2-.177 dia.  
Max. 1.299  
2-4.5×6 2-.177×6  
mounting holes  
M3.5 .138  
terminal screw  
30  
1.181  
3.4  
4
3
.134  
68±0.3  
2.677±.012  
Max. 78.5  
35.4  
1.394  
Max. 3.091  
6
8
5
7
19±0.2  
.748±.008  
General tolerance:  
.315 0.5 .020  
8
Max. 28.5  
Note: Round type terminal is unable to attach.  
Max. 1.122  
For Cautions for Use, see Relay Technical Information.  
ds_61C03_en_hl: 080413J  
10  

相关型号:

HL1-H-AC100V-F

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC

HL1-H-AC120V

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC

HL1-H-AC120V-F

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC

HL1-H-AC12V

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC

HL1-H-AC12V-F

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC

HL1-H-AC200-F

Electromechanical Relay, SPDT, AC Output,
PANASONIC

HL1-H-AC200V-F

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC

HL1-H-AC240-F

Electromechanical Relay, SPDT, AC Output,
PANASONIC

HL1-H-AC240V

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount
PANASONIC

HL1-H-AC24V

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC

HL1-H-AC24V-F

Power/Signal Relay, SPDT, Momentary, 1300mW (Coil), AC Input, AC Output, Panel Mount, ROHS COMPLIANT
PANASONIC

HL1-H-AC48V

Power/Signal Relay, SPDT, Momentary, 1200mW (Coil), 15A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount,
PANASONIC