JQ1AP-B-5V-F [PANASONIC]

Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
JQ1AP-B-5V-F
型号: JQ1AP-B-5V-F
厂家: PANASONIC    PANASONIC
描述:

Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

继电器
文件: 总5页 (文件大小:91K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
HIGH ELECTRICAL &  
MECHANICAL NOISE  
IMMUNITY RELAY  
JQ RELAYS  
FEATURES  
10  
20  
.787  
.394  
• High electrical noise immunity  
• High switching capacity in a compact  
package  
About Cd-free contacts  
We have introduced Cadmium free type  
products to reduce Environmental  
Hazardous Substances.  
(The suffix “F” should be added to the  
part number)  
Please replace parts containing  
Cadmium with Cadmium-free products  
and evaluate them with your actual  
application before use because the life of  
a relay depends on the contact material  
and load.  
15.6  
.614  
• High sensitivity: 200 mW (1a),  
400 mW (1c)  
• High surge voltage: 8,000 V between  
contacts and coil  
• UL, CSA,VDE, SEMKO approved and  
TÜV available  
• Class B coil insulation type also  
available.  
mm inch  
RoHS Directive compatibility information  
http://www.mew.co.jp/ac/e/environment/  
SPECIFICATIONS  
Contact  
Standard type  
High capacity type  
Arrangement  
1 Form A, 1 Form C  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
100 m  
Contact material  
AgSnO2 type  
1a  
5 A 125 V AC, 2 A 250 V AC, 5 A 30 V DC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC  
5 A 125 V AC, 2 A 250 V AC, 3 A 30 V AC 10 A 125 V AC, 5 A 250 V AC, 5 A 30 V DC  
Nominal switching  
capacity  
N.O.  
N.C.  
1c  
1a  
1c  
2 A 125 V AC, 1 A 250 V AC, 1 A 30 V DC  
625 VA, 150 W  
3 A 125 V AC, 2 A 250 V AC, 1 A 30 V DC  
1,250 VA, 150 W  
Rating  
(resistive)  
Max. switching power  
N.O.  
N.C.  
625 VA, 90 W  
1,250 V AC, 150 W  
250 VA, 30 W  
500 V AC, 30 W  
Max. switching voltage  
Max. switching current  
250 V AC, 110 V DC (0.3A)  
N.O.: 5 A N.C.: 2 A  
N.O.: 10 A N.C.: 3 A  
Min. switching capacity#1  
(Reference value)  
100 mA, 5 V DC  
107  
Expected mechanical life (at 180 cpm)(min. operations)  
Expected electrical life (min. operations)  
Type  
Switching capacity  
No. of operations  
5 A 125 V AC  
3 A 125 V AC  
2 A 250 V AC  
5 A 30 V DC  
5×104  
2×105  
2×105  
105  
1a  
5 A 125 V AC  
2 A 250 V AC  
3 A 30 V DC  
5×104  
2×105  
105  
2×105  
2×105  
105  
Standard type  
N.O.  
1c  
2 A 125 V AC  
1 A 250 V AC  
1 A 30 V DC  
N.C.  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
5×104  
5×104  
105  
1a  
10 A 125 V AC  
5 A 250 V AC  
5 A 30 V DC  
5×104  
5×104  
105  
2×105  
2×105  
105  
High capacity type  
N.O.  
N.C.  
1c  
3 A 125 V AC  
2 A 250 V AC  
1 A 30 V DC  
Coil (at 20°C 68°F)  
Nominal operating power  
1a: 200 mW  
1c: 400 mW  
#1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load.  
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.  
JQ  
Characteristics  
Max. operating speed  
Initial insulation resistance*1  
20 cpm  
Min. 1,000 Mat 500 V DC  
1a: 1,000 Vrms for 1 min.  
1c: 750 Vrms for 1 min.  
Between open contacts  
Initial breakdown voltage*2  
Between contacts and coil  
4,000 Vrms for 1 min.  
8,000 V  
Surge voltage between contact and coil*3  
Operate time*4 (at nominal voltage) (at 20°C 68°F)  
Release time*4 (at nominal voltage) (without diode) (at 20°C 68°F)  
Temperature rise*5 (coil)  
Max. 20 ms  
Max. 10 ms  
Max. 45°C  
Functional*6  
Destructive*7  
294 m/s2 {30 G}  
980 m/s2 {100 G}  
Shock resistance  
Functional*8  
10 to 55 Hz at double amplitude of 1.6 mm  
10 to 55 Hz at double amplitude of 2.0 mm  
–40°C to +85°C –40°F to +185°F  
5 to 85% R.H.  
Vibration resistance  
Destructive  
Ambient temp.*10  
Humidity  
Conditions for operation, transport and storage*9  
(Not freezing and condensing at low temperature)  
Unit weight  
Approx. 7 g .25 oz  
Remarks  
*
*
*
*
*
*
Specifications will vary with foreign standards certification ratings.  
Measurement at same location as “Initial breakdown voltage” section  
Detection current: 10 mA  
Wave is standard shock voltage of 1.2 × 50µs according to JEC-212-1981  
Excluding contact bounce time  
1
2
3
4
5
Measured conditions  
Standard type  
Resistance method, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70°C 158°F  
Resistance method, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70°C 158°F  
High capacity type  
6
*
*
*
*
*
Half-wave pulse of sine wave: 11ms; detection time: 10µs  
7
Half-wave pulse of sine wave: 6ms  
8
Detection time: 10µs  
9
Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.  
When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1°C 33.8°F with 20°C  
68°F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.  
10  
TYPICAL APPLICATIONS  
• Air conditioners  
• Refrigerators  
• Microwave ovens  
• Heaters  
ORDERING INFORMATION  
Ex. JQ  
1a  
P
B
12  
V
F
Contact  
Contact capacity  
arrangement  
Coil insulation class  
Coil voltage (DC)  
5, 6, 9, 12, 18, 24, 48* V  
Contact material  
F: AgSnO2 type  
1a: 1 Form A  
1: 1 Form C  
Nil: Standard  
P: High capacity  
Nil: Class E coil insulation  
B: Class B coil insulation  
UL/CSA, VDE, SEMKO approved type is standard.  
Notes: 1. Standard packing: Carton: 100 pcs. Case: 500 pcs.  
2. *Available only for 1 Form C type  
3. Please inquire about the previous products (Cadmium containing parts).  
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.  
JQ  
TYPES AND COIL DATA at 20°C 68°F  
Pick-up  
voltage, V DC  
(min.)  
Drop-out  
Nominal  
operating  
current, mA  
Nominal  
operating  
power, mW  
Nominal  
Coil resistance, Max. allowable  
Part No.  
voltage, V DC  
(min.)  
voltage, V DC  
( 10%)  
voltage, V DC  
JQ1a-5V-F  
JQ1a-6V-F  
JQ1a-9V-F  
JQ1a-12V-F  
JQ1a-18V-F  
JQ1a-24V-F  
JQ1aP-5V-F  
JQ1aP-6V-F  
JQ1aP-9V-F  
JQ1aP-12V-F  
JQ1aP-18V-F  
JQ1aP-24V-F  
JQ1-5V-F  
5
6
3.75  
4.5  
6.75  
9
0.25  
0.3  
40  
125  
180  
33.3  
22.2  
16.7  
11.1  
8.3  
180% of  
nominalvoltage  
(at 20°C 68°F)  
9
0.45  
0.6  
405  
200  
200  
12  
18  
24  
5
720  
13.5  
18  
0.9  
1,620  
2,880  
125  
1.2  
4
0.25  
0.3  
40  
6
4.8  
7.2  
9.6  
14.4  
19.2  
3.75  
4.5  
6.75  
9
33.3  
22.2  
16.7  
11.1  
8.3  
180  
130% of  
nominalvoltage  
(at 85°C 185°F)  
9
0.45  
0.6  
405  
12  
18  
24  
5
720  
0.9  
1,620  
2,880  
62.5  
90  
1.2  
0.25  
0.3  
80  
JQ1-6V-F  
6
66.7  
44.4  
33.3  
22.2  
16.7  
8.3  
JQ1-9V-F  
9
0.45  
0.6  
202.5  
360  
150% of  
nominalvoltage  
(at 20°C 68°F)  
JQ1-12V-F  
JQ1-18V-F  
JQ1-24V-F  
JQ1-48V-F  
JQ1P-5V-F  
JQ1P-6V-F  
JQ1P-9V-F  
JQ1P-12V-F  
JQ1P-18V-F  
JQ1P-24V-F  
JQ1P-48V-F  
12  
18  
24  
48  
5
400  
13.5  
18  
0.9  
810  
1.2  
1,440  
5,760  
62.5  
90  
36  
2.4  
4
0.25  
0.3  
80  
6
4.8  
7.2  
9.6  
14.4  
19.2  
38.4  
66.7  
44.4  
33.3  
22.2  
16.7  
8.3  
9
0.45  
0.6  
202.5  
360  
110% of  
nominalvoltage  
(at 85°C 185°F)  
12  
18  
24  
48  
400  
0.9  
810  
1.2  
1,440  
5,760  
2.4  
Note) Class B coil insulation type also available:  
Ex) JQ1a--12V-F  
: input the following letter, class B: B.  
mm inch  
DIMENSIONS  
1 Form A  
Schematic (Bottom view)  
1 Form C  
1 Form A  
10  
20  
.394  
.787  
COM N.O.  
COM N.O.  
Coil  
Coil  
15.6  
.614  
N.C.  
0.4  
.016  
4.2  
.165  
7.62  
.300  
10.16  
.400  
0.3  
7.62  
.300  
7.62  
.300  
0.5 dia.  
0.3  
0.8  
.020 dia.  
.012  
.012  
.031  
PC board pattern (Bottom view)  
1FormC  
1 Form C  
1 Form A  
10  
20  
.787  
4-1.3 dia.  
5-1.3 dia.  
.394  
4-.051 dia.  
5-.051 dia.  
10.16  
.400  
7.62  
.300  
10.16  
.400  
7.62  
.300  
15.6  
.614  
7.62  
.300  
7.62  
.300  
0.4  
.016  
2.54  
.100  
4.2  
5.08  
.200  
2.54  
.100  
7.62  
.300  
10.16  
7.62  
.300  
.165  
.400  
0.3  
Tolerance: 0.1 .004  
0.5 dia.  
0.3  
0.8  
.031  
.020 dia.  
.012  
.012  
0.3  
.012  
Dimension :  
Max. 1mm .039 inch  
General tolerance  
0.2 .008  
1 to 5mm .039 to .118 inch 0.3 .012  
Min. 5mm .118 inch 0.4 .016  
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.  
JQ  
REFERENCE DATA  
Max. switching capacity (1 Form A type)  
Max. switching capacity (1 Form C type)  
100  
100  
AC resistive load  
(High capacity type) N.O. side  
AC resistive load  
(Standard type) N.O. side  
AC resistive load (High capacity type)  
10  
5
10  
5
3
2
AC resistive load  
AC resistive load (Standard type)  
1
1
(High capacity type)  
N.C. side  
AC resistive load  
(Standard type)  
N.C. side  
10  
100 250  
1,000  
10  
100 250  
1,000  
Contact voltage, V  
Contact voltage, V  
Standard type  
1-(1). Operate & release time (1 Form A type)  
Tested sample: JQ1a-12V-F, 25 pcs.  
1-(2). Operate & release time (1 Form C type)  
Tested sample: JQ1-24V-F, 25 pcs.  
2. Life curve  
Ambient temperature: room temperature  
100  
8
8
125V AC resistive load  
6
6
Operate time  
Operate time  
10  
4
4
250V AC resistive load  
Max.  
Max.  
Max.  
Max.  
Min.  
Min.  
2
2
Min.  
Min.  
Release time  
Release time  
1
0
0
80  
100  
120  
150  
80  
100  
120  
150  
0
1
2
3
4
5
Contact current, A  
Coil applied voltage, %V  
Coil applied voltage, %V  
3-(1). Coil temperature rise (1 Form A type)  
3-(2). Coil temperature rise (1 Form C type)  
Contact carrying current: 3 A, 5 A  
Measured portion: Inside the coil  
Contact carrying current: 3 A, 5 A  
Measured portion: Inside the coil  
50  
70  
60  
40  
5 A at 70°C  
5 A at 70°C  
50  
3 A at 70°C  
5 A at 85°C  
30  
40  
5 A at 85°C  
30  
20  
3 A at 70°C  
3 A at 85°C  
20  
3 A at 85°C  
10  
10  
0
0
100 110 120 130 140 150 160 170 180 190  
100 110 120 130 140 150 160  
Coil applied voltage, %V  
Coil applied voltage, %V  
4-(1). Ambient temperature characteristics  
(1 Form A type)  
4-(2). Ambient temperature characteristics  
(1 Form C type)  
Tested sample: JQ1a-24V-F  
Contact carrying current: 3 A, 5 A  
Tested sample: JQ1-24V-F  
Contact carrying current: 3 A, 5 A  
1 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 3 A)  
2 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 5 A)  
400  
400  
300  
300  
1
3 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 3 A)  
4 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 5 A)  
1
2
2
200  
200  
3
3
4
5
5
6
4
100  
100  
5 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 5 A)  
6
7
7
6 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 3 A)  
0
0
20 30 40 50 60 70 80 90  
20 30 40 50 60 70 80 90  
7 Pick-up voltage  
Ambient temperature, °C  
Ambient temperature, °C  
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.  
JQ  
High capacity type  
1-(1). Operate & release time (1 Form A type)  
Tested sample: JQ1aP-12V-F, 25 pcs.  
1-(2). Operate & release time (1 Form C type)  
Tested sample: JQ1P-12V-F, 25 pcs.  
2. Life curve  
Ambient temperature: room temperature  
100  
8
6
8
6
4
2
0
Operate time  
125V AC resistive load  
10  
Operate time  
4
Max.  
Min.  
Max.  
Min.  
Max.  
Max.  
250V AC resistive load  
Min.  
Min.  
2
0
Release time  
120  
Release time  
120  
1
80  
100  
150  
80  
100  
150  
0
2
4
6
8
10  
Contact current, A  
Coil applied voltage, %V  
Coil applied voltage, %V  
3-(1). Coil temperature rise (1 Form A type)  
3-(2). Coil temperature rise (1 Form C type)  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
Contact carrying current: 5 A, 10 A  
Measured portion: Inside the coil  
70  
70  
10 A at 85°C  
60  
60  
10 A at 85°C  
10 A at 70°C  
50  
50  
10 A at 70°C  
5 A at 70°C  
40  
40  
5 A at 85°C  
30  
20  
10  
0
5 A at 70°C  
30  
5 A at 85°C  
20  
10  
0
100  
120  
140  
160  
180  
100 110 120 130 140 150 160  
Coil applied voltage, %V  
Coil applied voltage, %V  
4-(1). Ambient temperature characteristics  
(1 Form A type)  
4-(2). Ambient temperature characteristics  
(1 Form C type)  
Tested sample: JQ1aP-24V-F  
Contact carrying current: 5 A, 10 A  
Tested sample: JQ1P-24V-F  
Contact carrying current: 5 A, 10 A  
1 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 5 A)  
2 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 130°C 266°F) (Carrying current: 10 A)  
400  
400  
300  
1
2
300  
3 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 5 A)  
4 Allowable ambient temperature against  
% coil voltage (max. inside the coil temperature  
set as 115°C 239°F) (Carrying current: 10 A)  
1
2
200  
200  
100  
3
3
4
5
4
5
100  
5 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 10 A)  
6
7
6
7
6 Pick-up voltage with a hot-start condition  
of 100%V on the coil (Carrying current: 5 A)  
0
20 30 40 50 60 70 80 90  
0
20 30 40 50 60 70 80 90  
7 Pick-up voltage  
Ambient temperature, °C  
Ambient temperature, °C  
NOTES  
Note about relay installation orientation  
Top  
When installing with the relay terminals  
parallel to the ground, the contact  
terminals at the bottom and the coil  
terminals at the top, component friction  
will occur after numerous switching  
actions or due to vibration in the non-  
excitation state. Since this may cause the  
relay to stop functioning when the pick-up  
voltage increases even if the nominal  
voltage is applied, please do not install  
using this orientation.  
Bottom  
For Cautions for Use, see Relay Technical Information.  
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.  

相关型号:

JQ1AP-B-6V-F

Power/Signal Relay, SPST, Momentary, 0.033A (Coil), 6VDC (Coil), 200mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

JQ1AP-B-9V-F

Power/Signal Relay, SPST, Momentary, 0.022A (Coil), 9VDC (Coil), 200mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC

JQ1AP-XX

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1APE-24V-H12

1a/1c 5A/10A small power relays
PANASONIC

JQ1P-12V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1P-12V

Power/Signal Relay,
PANASONIC

JQ1P-12V-F

1a/1c 5A/10A small power relays Class B coil insulation type also available.
PANASONIC

JQ1P-18V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1P-18V-F

1a/1c 5A/10A small power relays Class B coil insulation type also available.
PANASONIC

JQ1P-24V

HIGH ELECTRICAL MECHANICAL NOISE IMMUNITY RELAY
NAIS

JQ1P-24V

Power/Signal Relay, 1 Form C, SPDT, Momentary, 0.017A (Coil), 24VDC (Coil), 400mW (Coil), 3A (Contact), 110VDC (Contact), DC Input, Random, AC/DC Output, Through Hole-Straight Mount,
PANASONIC

JQ1P-24V-F

1a/1c 5A/10A small power relays Class B coil insulation type also available.
PANASONIC