OS-RXL-1 [PANASONIC]

Adjustable Range Reflective Photoelectric Sensor;
OS-RXL-1
型号: OS-RXL-1
厂家: PANASONIC    PANASONIC
描述:

Adjustable Range Reflective Photoelectric Sensor

文件: 总6页 (文件大小:364K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Amplifier Built-in  
Adjustable Range Reflective Photoelectric Sensor  
343  
RX-LS200  
General terms and conditions............ F-3  
Glossary of terms....................... P.1549~  
Selection guide...............................P.231~  
General precautions................... P.1552~  
FIBER  
SENSORS  
Related Information  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
panasonic.net/id/pidsx/global  
PNP output  
type available  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
Detection of different  
colored objects at a certain distance  
PLC  
HUMAN MACHINE  
INTERFACES  
Hardly affected by color  
Hardly affected by background  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Background  
(specular)  
The color or size of the object does not affect its sensing  
performance.  
The sensor does not detect  
the background beyond the  
set distance since it is of  
distance adjustable type.  
FA COMPONENTS  
MACHINE VISION  
SYSTEMS  
Robust  
Its robust enclosure is made of die-cast zinc alloy.  
UV CURING  
SYSTEMS  
However, changing the angle of the sensor  
is necessary when the background object  
has a specular surface.  
ENVIRONMENTAL RESISTANCE  
Waterproof IP67 (IEC)  
BASIC PERFORMANCE  
Selection  
Guide  
Amplifier  
Built-in  
High-speed response time: 1 ms  
It can be used on a high speed assembly line.  
Power Supply  
Built-in  
The equipment on which the sensor is mounted can be  
washed without any problem.  
Amplifier-  
separated  
Note: However, take care that if it is exposed to water splashes  
during operation. It may detect a water drop itself.  
Adjustable Range Reflective Type  
EX-Z  
CX-400  
CY-100  
EX-10  
The sensing range for which the sensor detects an  
object is determined by the incident beam angle,  
regardless of the incident light intensity.  
Insusceptible to dust  
RX-LS200  
EX-20  
The sensing performance  
Dust  
Receiving element  
EX-30  
is less affected by dust as  
it does not depend on the  
incident light intensity.  
Receiving lens  
(2-segment device)  
The sensing range can be changed  
EX-40  
according to the position of the lens.  
Sensing object  
Sensing object  
CX-440  
EQ-30  
EQ-500  
MQ-W  
Emitting lens  
Sensing range  
Emitting LED  
RX-LS200  
RX  
RT-610  
Adjustable Range Reflective Photoelectric Sensor RX-LS200  
344  
APPLICATIONS  
FIBER  
SENSORS  
LASER  
Detecting lids of cups  
Safekeeping at parking garage  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
COMPONENTS  
Cut a hole on the conveyor  
line so that the beam cannot  
be reflected without a lid.  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
SENSORS  
ORDER GUIDE  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Type  
Appearance  
Sensing range  
Model No.  
Output  
WIRE-SAVING  
SYSTEMS  
NPN output  
PNP output  
NPN open-collector transistor  
PNP open-collector transistor  
RX-LS200  
MEASURE-  
MENT  
50 to 200 mm  
1.969 to 7.874 in  
SENSORS  
RX-LS200-P  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
5 m cable length type  
5 m 16.404 ft cable length type (standard: 3 m 9.843 ft) is also available for NPN output type.  
Model No.: RX-LS200-C5  
PLC  
HUMAN  
MACHINE  
INTERFACES  
Accessory  
ENERGY  
MS-RX-1 (Sensor mounting bracket)  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Two M4 (length 16 mm 0.630 in)  
hexagon-socket-head bolts are attached.  
OPTIONS  
Selection  
Guide  
Amplifier  
Built-in  
Narrow-view slit mask  
Power Supply  
Built-in  
Designation  
Model No.  
Description  
• OS-RXL-□  
Amplifier-  
separated  
2.5 × 24 mm  
0.098 0.945 in  
OS-RXL-1  
OS-RXL-2  
OS-RXL-3  
PT-RX500  
PT-RX1000  
EX-Z  
The sensing view is narrowed laterally  
so that the effect of the object’s  
surroundings is reduced.  
Narrow-view  
slit mask  
3.0 × 24 mm  
0.118 0.945 in  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
3.5 × 24 mm  
0.138 0.945 in  
500 mm  
19.685 in  
Protective tube  
Cable is protected from external forces.  
It does not rust as it is made of  
stainless steel.  
Protective tube  
• PT-RX500  
• PT-RX1000  
1,000 mm  
39.370 in  
Protective tube  
RT-610  
Adjustable Range Reflective Photoelectric Sensor RX-LS200  
345  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
Adjustable range reflective  
Type  
PHOTO-  
ELECTRIC  
SENSORS  
NPN output type  
PNP output type  
Item  
Model No.  
RX-LS200  
RX-LS200-P  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
CE marking directive compliance  
Sensing range  
EMC Directive, RoHS Directive  
50 to 200 mm 1.969 to 7.874 in with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
10 % or less of operation distance with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
Along sensing axis: 1 mm 0.039 in or less, Perpendicular to sensing axis: 0.5 mm 0.020 in or less  
12 to 24 V DC ±10 % Ripple P-P 10 % or less  
AREA  
SENSORS  
Hysteresis  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
Repeatability  
COMPONENTS  
PRESSURE /  
FLOW  
Supply voltage  
SENSORS  
Current consumption  
40 mA or less  
INDUCTIVE  
PROXIMITY  
SENSORS  
NPN open-collector transistor  
PNP open-collector transistor  
• Maximum sink current: 100 mA  
• Maximum source current: 100 mA  
PARTICULAR  
USE  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 1.5 V or less (at 100 mA sink current)  
0.4 V or less (at 16 mA sink current)  
• Applied voltage: 30 V DC or less (between output and +V)  
• Residual voltage: 1 V or less (at 100 mA source current)  
0.4 V or less (at 16 mA source current)  
Output  
SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
Utilization category  
Output operation  
Short-circuit protection  
Response time  
DC-12 or DC-13  
Switchable either Light-ON or Dark-ON  
WIRE-SAVING  
SYSTEMS  
Incorporated  
MEASURE-  
MENT  
1 ms or less  
SENSORS  
Operation indicator  
Stability indicator  
Distance adjuster  
Pollution degree  
Protection  
Red LED (lights up when the output is ON)  
STATIC  
CONTROL  
DEVICES  
Green LED (lights up under stable light received condition or stable dark condition)  
2-turn mechanical adjuster  
LASER  
MARKERS  
3 (Industrial environment)  
PLC  
IP67 (IEC)  
HUMAN  
MACHINE  
Ambient temperature  
Ambient humidity  
Ambient illuminance  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Emitting element  
Material  
–25 to 60 °C –13 to 140 °F (No dew condensation or icing allowed), Storage: –30 to 70 °C –22 to 158 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Incandescent light: 3,500 ℓx or less at the light-receiving face  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each  
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each  
Infrared LED (peak emission wavelength: 880 nm 0.035mil, modulated)  
Enclosure: Die-cast zinc alloy, Indicator cover: Polyethersulphone, Lens: Polycarbonate  
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 3 m 9.843 ft long  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
Net weight: 85 g approx.  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
CURING  
SYSTEMS  
Cable  
Selection  
Guide  
Cable extension  
Weight  
Amplifier  
Built-in  
Power Supply  
Built-in  
Accessories  
MS-RX-1 (Sensor mounting bracket): 1 set, Adjusting screwdriver: 1 pc.  
Amplifier-  
separated  
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.  
I/O CIRCUIT AND WIRING DIAGRAMS  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
NPN output type  
RX-LS200  
I/O circuit diagram  
Wiring diagram  
Color code  
(Brown) +V  
D
ZD  
Brown  
Black  
Blue  
Load  
+
(Black) Output  
12 to 24 V DC  
10 %  
Load  
100 mA max.  
(Blue) 0 V  
+
12 to 24 V DC  
Tr  
1ꢀ %  
Internal circuit  
Users’ circuit  
Symbols … D : Reverse supply polarity protection diode  
ZD: Surge absorption zener diode  
RT-610  
Tr : NPN output transistor  
Adjustable Range Reflective Photoelectric Sensor RX-LS200  
346  
I/O CIRCUIT AND WIRING DIAGRAMS  
FIBER  
SENSORS  
LASER  
SENSORS  
PNP output type  
RX-LS200-P  
PHOTO-  
I/O circuit diagram  
Wiring diagram  
ELECTRIC  
SENSORS  
Color code  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
(Brown) +V  
Tr  
Brown  
Black  
Blue  
AREA  
100 mA max.  
+
12  
24 V DC  
to  
SENSORS  
10 %  
(Black) Output (Note)  
+
SAFETY LIGHT  
CURTAINS /  
SAFETY  
12 to 24 V DC  
1ꢀ %  
Load  
ZD  
D
(Blue) 0 V  
COMPONENTS  
Load  
PRESSURE /  
FLOW  
Internal circuit  
Users’ circuit  
SENSORS  
Note: The output does not incorporate a short-circuit protection circuit.  
Do not connect it directly to a power supply or a capacitive load.  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
Symbols … D : Reverse supply polarity protection diode  
ZD: Surge absorption zener diode  
SENSORS  
Tr : PNP output transistor  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
SENSING CHARACTERISTICS (TYPICAL)  
WIRE-SAVING  
SYSTEMS  
Sensing fields  
MEASURE-  
MENT  
SENSORS  
Setting distance: 200 mm  
Setting distance: 200 mm  
Setting distance: 150 mm  
Setting distance: 150 mm  
7.874 in (Horizontal)  
7.874 in (Vertical)  
5.906 in (Horizontal)  
5.906 in (Vertical)  
STATIC  
CONTROL  
DEVICES  
200  
200  
200  
200  
7.874  
7.874  
7.874  
7.874  
N50o×n50-gmlmos1.s9y69p×a1.p96e9rin  
White non-  
White non-  
Gray non-  
White non-  
LASER  
glossy paper  
glossy paper  
glossy paper  
glossy paper  
MARKERS  
White non-  
(
Lightness: 3)  
150  
150  
150  
150  
L
5.906  
5.906  
5.906  
5.906  
5.5 mm 0.217 in  
glossy paper  
PLC  
Sensor  
51.096×9 ×510.9m69min  
51.096×9 ×510.9m69min  
50 × 50 mm  
1.969 × 1.969 in  
Non-glossy  
paper  
100  
100  
100  
100  
3.937  
3.937  
3.937  
3.937  
HUMAN  
Gray non-  
Non-glossy  
paper  
Non-glossy  
paper  
Gray non-  
MACHINE  
INTERFACES  
glossy paper  
glossy paper  
(Lightness: 3)  
(
Lightness: 3)  
50  
50  
50  
50  
ENERGY  
L
L
L
6 mm  
1.969  
1.969  
1.969  
1.969  
6 mm  
MANAGEMENT  
SOLUTIONS  
5.5 mm  
0.236 in  
0.236 in  
0.217 in  
Gray non-glossy paper  
(Lightness: 3)  
Sensor  
Sensor  
Sensor  
FA  
0
0
0
0
COMPONENTS  
10  
5
0.197  
Left  
Operating point ℓ (mm in)  
0
5
10  
10  
5
0
5
10  
4
2
0.079  
Left  
0
2
4
4
2
0.079  
Up  
0
2
4
0.394  
0.197  
0.394  
0.394  
0.197  
Up  
0.197  
Down  
0.394  
0.157  
0.079  
0.157  
0.157  
0.079 0.157  
Down  
Center  
Right  
Center  
Center  
Right  
Center  
MACHINE  
VISION  
Operating point ℓ (mm in)  
Operating point ℓ (mm in)  
Operating point ℓ (mm in)  
SYSTEMS  
UV  
Setting distance: 150 mm  
5.906 in with slit mask  
(Horizontal)  
Setting distance: 150 mm  
5.906 in with slit mask  
(Vertical)  
CURING  
SYSTEMS  
200  
200  
7.874  
7.874  
Common for  
OS-RXL-1  
Selection  
Guide  
150  
150  
OS-RXL-2  
OS-RXL-3  
5.906  
5.906  
Amplifier  
Built-in  
51.096×9 ×510.9m69min  
51.096×9 ×510.9m69min  
100  
100  
Power Supply  
OS-RXL-1  
OS-RXL-2  
OS-RXL-3  
3.937  
3.937  
Built-in  
Non-glossy  
paper  
Non-glossy  
paper  
Amplifier-  
separated  
50  
50  
L
1.969  
1.969  
6 mm  
L
5.5 mm 0.217 in  
0.236 in  
EX-Z  
Sensor  
2
0.079  
Left  
Sensor  
0
0
4
0
2
4
4
2
0
2
4
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
0.157  
0.079  
0.157  
0.157  
0.079  
Up  
0.079  
0.157  
Center  
Right  
Center  
Down  
Operating point ℓ (mm in)  
Operating point ℓ (mm in)  
Correlation between sensing object size and sensing range  
Emitted beam  
200  
ø7.5 mm  
ø0.295 in  
200  
7.874  
200 mm  
7.874 in  
7.874  
White non-glossy paper  
These curves show the characteristics with the  
maximum sensing range set to 100 mm 3.937 in,  
200 mm 7.874 in, each, with white non-glossy  
paper (50 × 50 mm 1.969 × 1.969 in).  
Gray non-glossy paper  
(Lightness: 3)  
150  
ø6.5 mm  
ø0.256 in  
150  
5.906  
5.906  
White non-glossy paper  
100  
ø6 mm  
ø0.236 in  
100  
100 mm  
3.937 in  
3.937  
3.937  
a × a mm in  
Gray non-glossy  
paper  
Non-glossy  
paper  
50  
(Lightness: 3)  
ø5 mm  
ø0.197 in  
50  
1.969  
1.969  
L
Sensor  
0
0
20  
40  
1.575  
60  
80  
3.150  
0.787  
2.362  
RT-610  
White non-glossy paper  
side length a (mm in)  
Adjustable Range Reflective Photoelectric Sensor RX-LS200  
347  
FIBER  
SENSING CHARACTERISTICS (TYPICAL)  
SENSORS  
LASER  
Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range  
SENSORS  
200  
7.874  
PHOTO-  
ELECTRIC  
SENSORS  
150  
MICRO  
PHOTO-  
5.906  
ELECTRIC  
SENSORS  
100  
AREA  
3.937  
SENSORS  
These bars indicate the sensing range  
SAFETY LIGHT  
CURTAINS /  
SAFETY  
with respective objects when the  
···  
200 mm 7.874 in  
50  
distance adjuster is set at the sensing  
1.969  
···  
100 mm 3.937 in  
COMPONENTS  
range of 200 mm 7.874 in, 100 mm  
···  
PRESSURE /  
FLOW  
50 mm 1.969 in  
3.937 in and 50 mm 1.969 in long,  
SENSORS  
0
each, with white non-glossy paper.  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
SENSORS  
SENSOR  
OPTIONS  
PRECAUTIONS FOR PROPER USE  
Refer to p.1552~ for general precautions.  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
• If a specular body is present in the background, wrong  
operation may be caused due to a small change in the  
angle of the background body. In that case, install the  
sensor at an inclination and confirm the operation with  
the actual sensing object.  
• Do not install the sensor at a distance of less than 50 mm  
1.969 in from the object because the sensing is unstable  
in this range.  
• Never use this product as a sensing device  
for personnel protection.  
• In case of using sensing devices for  
personnel protection, use products which  
meet laws and standards, such as OSHA,  
ANSI or IEC etc., for personnel protection  
applicable in each region or country.  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
PLC  
Wiring  
Mounting  
HUMAN  
MACHINE  
• The tightening torque should be 1.17 N·m or less.  
• The output of RX-LS200-P does not incorporate a short-  
circuit protection circuit. Do not connect it directly to a  
power supply or a capacitive load.  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
5.5 mm  
0.217 in  
M4 (length 16 mm 0.630 in)  
hexagon-socket-head bolt  
FA  
COMPONENTS  
Use conditions to comply with CE Marking  
Sensor mounting  
bracket  
MS-RX-1  
(Accessory)  
MACHINE  
VISION  
• Following work must be done in case of using this  
product as a CE marking (European standard EMC  
Directive) conforming product.  
SYSTEMS  
6 mm  
UV  
CURING  
0.236 in  
Beam axis  
SYSTEMS  
The sensing axis is  
positioned at the  
Ensure that the shield is connected to 0 V or the actual  
ground.  
intersection of the “  
mark on the lens face  
and the “ ” line.  
• In case of connecting a sensor to power supply 0 V by using  
a shield (piping, etc.)  
• Care must be taken regarding the sensor mounting  
direction with respect to the object’s direction of movement.  
Selection  
Guide  
+V  
Amplifier  
Built-in  
Shield (piping, etc.)  
Power supply  
0 V  
Correct  
Correct  
Incorrect  
Power Supply  
Built-in  
Sensor  
/
Load  
OUT  
Amplifier-  
separated  
Note: The shield (piping, etc.) must be insulated.  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
• In case of grounding by using a shield (piping, etc.)  
+V  
Shield (piping, etc.)  
Sensing object  
Power supply  
Sensing object  
Sensing object  
0 V  
/
Sensor  
Do not make the sensor  
detect an object in this  
direction because it may  
cause unstable operation.  
Load  
OUT  
• When detecting a specular object (aluminum or copper  
foil) or an object having a glossy surface or coating,  
please take care that there are cases when the object  
may not be detected due to a small change in angle,  
wrinkles on the object surface, etc.  
• When a specular body is present below the sensor, use  
the sensor by tilting it slightly upwards to avoid wrong  
operation.  
Others  
• Do not use during the initial transient time (50 ms) after  
the power supply is switched on.  
RT-610  
Adjustable Range Reflective Photoelectric Sensor RX-LS200  
348  
PRECAUTIONS FOR PROPER USE  
FIBER  
Refer to p.1552~ for general precautions.  
SENSORS  
Distance adjustment  
LASER  
Adjusting procedure  
SENSORS  
<When a sensing object moves horizontally to the sensor>  
Adjusters  
PHOTO-  
ELECTRIC  
SENSORS  
Pointer  
Distance adjuster (2-turn)  
MICRO  
Step  
Description  
Distance adjuster  
PHOTO-  
ELECTRIC  
SENSORS  
It shows how much  
the distance adjuster  
is rotated.  
The sensing range  
increases as it is  
turned clockwise.  
Turn the distance adjuster fully counterclockwise  
to the minimum sensing range position (50 mm  
1.969 in approx.).  
AREA  
SENS  
SENSORS  
1
SAFETY LIGHT  
CURTAINS /  
SAFETY  
Operation mode switch  
RX-LS200  
MODE  
L
(Do not turn excessively.)  
Turn  
L: Light-ON  
D: Dark-ON  
(Turn the switch fully.)  
D
COMPONENTS  
PRESSURE /  
FLOW  
Place an object at the required distance from  
the sensor, turn the distance adjuster gradually  
SENSORS  
Operation indicator (Red)  
Lights up when the  
output is ON.  
2
3
A
clockwise, and find out point “ ” where the  
INDUCTIVE  
PROXIMITY  
SENSORS  
sensor changes to the light received condition.  
A
Remove the object, turn the distance adjuster  
further clockwise, and find out point “ ” where  
the sensor changes to the light received  
condition again with only the background.  
Stability indicator (Green)  
PARTICULAR  
USE  
B
SENSORS  
Lights up under stable light received  
condition or stable dark condition.  
SENSOR  
OPTIONS  
B
A
When the sensor does not go to the light  
received condition even if the adjuster is fully  
SIMPLE  
WIRE-SAVING  
UNITS  
B
turned clockwise, point “ ” is this extreme  
point.  
WIRE-SAVING  
SYSTEMS  
MEASURE-  
MENT  
The optimum position to stably detect objects is  
B
A
4
A
B
the center point between “ ” and “ ”.  
SENSORS  
Optimum position  
STATIC  
CONTROL  
DEVICES  
<When a sensing object is approaching / moving away from the sensor>  
LASER  
1
2
• Follow only steps and respectively. Since the sensing point  
may change depending on the sensing object, be sure to check  
the operation with the actual sensing object.  
MARKERS  
PLC  
DIMENSIONS (Unit: mm in)  
HUMAN  
The CAD data can be downloaded from our website.  
MACHINE  
INTERFACES  
Sensor  
Protective tube (Optional)  
RX-LS200 RX-LS200-P  
PT-RX500 PT-RX1000  
ENERGY  
MANAGEMENT  
SOLUTIONS  
Operation mode switch  
Distance adjuster (2-turn)  
Pointer  
ø18  
L
Stability indicator (Green)  
Cover-fixing screw  
ø0.709  
ø5  
9
15  
FA  
ø0.197  
0.354  
0.591  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
UV  
Operation indicator (Red)  
14 0.551  
Indicator cover  
14  
CURING  
SYSTEMS  
ø7 ø0.276 spiral tube  
[Stainless steel (SUS304)]  
ø10 ø0.394  
(Brass)  
M10 × 1 0.039 thread  
(2.5)  
0.551  
35  
Beam-  
(0.098)  
[Brass (C3604) (Nickel plated)]  
1.378  
3 0.118  
receiving part  
2-M4 × 0.7 0.028  
thru-hole threads  
Internal thread  
M8 × 0.75 0.030, 4 0.157 deep  
3.6  
14  
Sensing axis  
• Length L  
35  
0.142  
0.551  
Selection  
Guide  
1.378  
Model No.  
PT-RX500  
PT-RX1000  
Length L  
14  
Amplifier  
Built-in  
0.551  
+10  
0
+0.394  
19.685  
0
Beam-  
500  
Power Supply  
emitting part  
Built-in  
+10  
0
+0.394  
39.370  
0
1,000  
6
Amplifier-  
separated  
ø3.7ø0.146 cable, 3 m 9.843 ft long  
M8 × 0.75 0.030  
5.5  
1.5  
0.236  
0.217  
0.059  
Sensor mounting bracket (Accessory)  
MS-RX-1  
EX-Z  
Assembly dimensions  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
8
Sensing axis  
10  
0.394  
0.315  
16  
16.5  
4.4  
0.713  
0.630  
18.5  
0.728  
0.650  
4.4  
0.173  
4.4  
8
0.173  
10  
0.315  
8.5  
0.335  
Material: Cold rolled carbon steel (SPCC)  
0.394  
4.4  
10  
0.394  
Two M4 (length 16 mm 0.630 in) hexagon-socket-  
head bolts are attached.  
0.173  
37  
6
8.5  
0.335  
37 1.457  
0.236  
13.5  
13.5  
14  
0.551  
(2.5)  
(0.098)  
1.457  
35  
1.378  
0.531  
15°  
0.531  
5
0.197  
2
4.4  
0.173  
0.079  
5 0.197  
R14 R0.551  
3 0.118  
Sensing axis  
45  
38  
45  
1.772  
1.772  
1.496  
24  
t 2  
15°  
0.945  
t 0.079  
16  
0.630  
RT-610  
16 0.630  
24.5 0.965  
30 1.181  

相关型号:

OS-RXL-2

Adjustable Range Reflective Photoelectric Sensor
PANASONIC

OS-RXL-3

Adjustable Range Reflective Photoelectric Sensor
PANASONIC

OS02A1Q

Ultra Low-Light Performance
OMNIVISION

OS02A1Q-H92A-Z

Ultra Low-Light Performance
OMNIVISION

OS02C10

Image Sensor Combines Ultra Low Light
OMNIVISION

OS02C10-J70A-Z

Image Sensor Combines Ultra Low Light
OMNIVISION

OS02F10

Backside Illumination 2-Megapixel 1080p Image Sensor
OMNIVISION

OS02F10-A34A

Backside Illumination 2-Megapixel 1080p Image Sensor
OMNIVISION

OS02N-DFSVP012

OS-CON DATA SHEET
SANYO

OS04B10

Backside Illumination 3.6-Megapixel 2K Image Sensor
OMNIVISION

OS04B10-A51A

Backside Illumination 3.6-Megapixel 2K Image Sensor
OMNIVISION

OS05A10

Versatile 5-Megapixel PureCel® Sensor
OMNIVISION