SmartZoneG5 Intelligent Power  
Distribution Units (iPDUs)  
S P E C I F I C A T I O N S H E E T  
o v e r v i e w  
The Panduit® SmartZoneG5 iPDU is more than a power distribution unit and energy meter. These iPDUs monitor  
the data center power and environment (at the rack or cabinet level), by continuously scanning for electrical circuit  
overloads, and physical environmental conditions that place critical IT equipment at risk. Panduit’s iPDUs provide  
comprehensive, accurate, energy measurement data to efficiently use power resources, make informed capacity  
planning decisions, improve uptime, measure PUE (power usage effectiveness), and drive green data center  
initiatives to save energy and money.  
Making the right choice in IT equipment is essential for a safe, efficient data center operation. Our full range of iPDUs,  
environmental sensors, and dual locking power cords are the key to fulfilling mission‐critical data center needs.  
t e c h n i c a l i n f o r m a t i o n  
Dimensions:  
Height Inch (mm) Width Inch (mm)  
Depth Inch (mm)  
1U:  
1U:  
1U:  
2U:  
1.6 (40.6)  
1.7 (43.2)  
1.7 (43.2)  
3.4 (86.4)  
17.5 (444.5)  
17.5 (444.5)  
17.5 (444.5)  
17.5 (444.5)  
2.0 (50.8)  
7.8 (198.1)  
10.6 (269.2)  
7.8 (198.1)  
0U HALF:  
32.2 (817.9)  
2.0 (50.8)  
2.0 (50.8)  
2.0 (50.8)  
2.1 (53.3)  
4.4 (111.8)  
2.1 (53.3)  
0U HALF (2 sided): 36 (914.4)  
0U MID:  
58.7 (1491)  
0U FULL:  
68.9 (1750.1)  
2.0 (50.8)  
2.0 (50.8)  
2.1 (53.3)  
4.4 (111.8)  
0U FULL (2 sided): 71.7 (1821.2)  
0U Full +:  
0U Full Wide:  
0U Full Wide +:  
74.6 (1896)  
68.9 (1750.1)  
74.0 (1880)  
2.0 (50.8)  
3.3 (83.8)  
3.3 (83.8)  
2.1 (53.3)  
2.1 (53.3)  
2.1 (53.3)  
Mounting:  
Vertical units provide up to 48 outlets and without encroaching on the EIA  
space. Horizontal units provide up to 16 outlets and mount in standard  
(1U or 2U) TIA/EIA rack space.  
k e y f e a t u r e s a n d b e n e f i t s  
HotSwappable  
Controller:  
Replace the controller and display module without having to power down  
the rack  
Redundant Network  
Access:  
Specifically designed for Landlord/Tenant (Co-Lo’s) allowing for remote  
access of real-time, vital statistics and operating information on two  
separate, secure networks.  
Hardened Security:  
1GB Ethernet:  
Not only Physical but hardened Digital Security; layers within the firmware  
LDAP, SNMP v3, TLS, Encrypted Security; allows for Panduit PDUs to pass  
standard certified security scans.  
The 1G controller is compatible with the new Data Center Network switches  
being deployed - reducing special network configurations/resources required  
to support the iPDU.  
Plug & Play Sensors:  
Multi-Color PDUs:  
Digital sensors not only allow for multiple sensors on the same bus; but also  
identify themselves to the controller to simplify setup & commissioning.  
Different color PDUs simplify power feed identification & management. The  
new Panduit Intelligent PDUs are available in Black, White, Red, Blue,  
Yellow or Green.  
Mobile & Desktop  
Friendly Web GUI:  
The intelligent PDUs feature an enhanced designed web interface which  
detects the type of device that you are on; and automatically adjusts the  
screen for an optimal experience.  
Outlet Density:  
Form Factor:  
Meets demands of densely packed IT equipment in rack or cabinet space  
Optimal form factor enables efficient rack space utilization  
Operating Temperature: 60°C ambient at full load for operational reliability in high temperature areas  
(continued pg. 2)  
www.panduit.com  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
k e y f e a t u r e s a n d b e n e f i t s (continued)  
Cable Retention:  
Innovative cable tie accepting outlets allow for secure cord retention (C13 & C19 only) using a  
cable tie for added safety and security. (Panduit part number: PLT2I-C0)  
Circuit Breakers:  
Protects data center equipment for increased reliability by interrupting potentially hazardous circuit  
over-current conditions*  
Color Coded Circuits*:  
Easily identify phase to outlet banks to aid in fault isolation or load balancing  
External Chassis  
Ground:  
Meets NEC requirements and installation guidelines for IT equipment  
Load Balancing:  
Monitored through visual display on oLED (for 3 phase units only)  
Multiple Input Plug  
Options:  
A full breadth offering to seamlessly interoperate with existing building power wiring schemes  
Multiple Mounting  
Options:  
Enables simple out of the box commissioning and flexibility with Panduit cabinets and industry  
standard mounting features enabling installation into third party cabinets  
Mounting Buttons:  
Allows tool-less mounting of rack PDUs for faster installations on vertical 0U units  
Supported Metering:  
Frequency, VA, PF, plus aggregate and per phase Amperage, Voltage, Wattage, and Kilowatts  
per hour  
* Applies to products outfitted with circuit breakers  
i P D U p r o d u c t f a m i l i e s  
MI Series:  
Rack PDUs that have the ability for aggregate power monitoring to quickly identify potential power  
issues, and reclaim available or under-utilized power capacity.  
MS Series:  
Rack PDUs that have the ability for aggregate power monitoring and outlet level switching  
capabilities for individual outlets or a group of outlets. Enabling power sequencing, rebooting  
equipment or restrict unauthorized use of individual outlets.  
MPO Series:  
Rack PDUs that have the ability for outlet level (and aggregate) power monitoring to quickly  
identify potential power issues, and reclaim available or under-utilized power capacity at the outlet  
level enabling the redeployment or decommissioning of individual servers to reclaim available or  
under-utilized power capacity.  
MSPO Series:  
Rack PDUs that have the ability for outlet level (and aggregate) power monitoring and outlet level  
switching capabilities for individual outlets or a group of outlets. Power monitoring at the individual  
outlet level provides actionable management data on the power consumption of each connected  
IT device enabling the redeployment or decommissioning of individual servers to reclaim available  
or under-utilized power capacity. Ideal for remote power reset, and cabinet power on sequencing  
and restrict unauthorized use of individual outlets.  
e l e c t r i c a l s p e c i f i c a t i o n s  
North America  
International models  
Input Voltage  
• Single-Phase 120V  
• Single-Phase 240V  
• Single-Phase 208V  
• Three-Phase Wye 240/415V  
• Three-Phase Delta 208V  
• Three-Phase Wye 120/208V  
• Three-Phase Wye 415V  
Input Current (per phase)  
Input Power  
North America  
International models  
• 15A, 20A, 30A, 50A, 60A  
• 16A, 32A  
North America  
• 1.4 – 17.3 (kVA)  
International models  
• 3.7 – 22 (kVA)  
Input Frequency  
50/60 Hz  
Output Voltage  
120 - 240 VAC  
Maximum output current (outlet)  
IEC C13: 10A  
IEC C19: 16A  
NEMA 5-20R: 16A  
Overload protection (where applicable)  
Circuit Breakers, hydraulic magnetic  
10 kAIC Circuit Breakers for all 415V models for North America  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
g e n e r a l s p e c i f i c a t i o n s  
Temperature: Operating  
50° to 140° F (10° to 60° C)  
-4° to 140° F (-20° to 60° C)  
10% to 90% non-condensing  
5 to 95% RH  
Temperature: Storage  
Relative Humidity: Operating  
Relative Humidity: Non-Operating  
Relative Humidity: Storage  
Elevation: Operating  
5% to 95%  
0 to 10,000 ft. (0 to 3000 m)  
0 to 30,000 ft. (0 to 9144 m)  
Elevation: Storage  
Conformance Standards  
North America - UL, CB Test Approved  
International - CE Approved, EAC Russia Approval  
Environmental Compliances  
RoHS & REACH  
c a b i n e t c o m p a t i b i l i t y  
Panduit iPDUs can be easily installed into Panduit (or third party cabinets) by utilizing the installed mounting buttons  
(18.4 mm diameter). Where necessary, a Small Diameter (14.5 mm) mounting button is available (sold separately,  
p/n: MA018). Panduit PDUs feature threaded inserts on the back and both sides for the ultimate in mounting flexibility.  
They safely and efficiently manage and distribute power to multiple devices through a single input power connector,  
per PDU, to enhance scalability of network build outs.  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Input - MI Series  
Input  
Apparent  
Power  
(kVA)  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
Outlet Configuration  
(inches) (inches)  
NA  
INTL  
NA  
15  
16  
20  
20  
20  
50  
30  
30  
32  
15  
20  
20  
16  
20  
30  
30  
32  
30  
32  
32  
50  
1U  
1U  
5-15P  
0
0
0
0
0
3
2
2
2
0
0
0
0
0
2
2
2
2
2
2
3
1.4  
3.7  
1.9  
1.9  
3.3  
8.3  
2.9  
5.0  
7.4  
1.4  
1.9  
1.9  
3.7  
3.3  
2.9  
5.0  
7.4  
5.0  
7.4  
7.4  
8.3  
8
(8)5-20R  
1.7  
1.7  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
2.0  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
2.1  
P08D09M  
P12D36M  
P08D10M  
P08D11M  
P12D13M  
P06D15M  
P16D12M  
P16D14M  
P16D37M  
P16D20M  
P16D21M  
P16D22M  
P24D40M  
P24D24M  
P24D23M  
P24D07M  
P24D03M  
P38D25M  
P34D41M  
P42D06M  
P36D26M  
IEC 60309-316P6  
5-20P  
12  
8
(12)C13  
(8)5-20R  
(8)5-20R  
(12)C13  
(6)C19  
1U  
1.7  
NA  
1U  
L5-20P  
8
1.7  
NA  
1U  
L6-20P  
12  
6
1.7  
NA  
1U  
CS8265C  
L5-30P  
1.7  
NA  
2U  
16  
16  
16  
16  
16  
16  
24  
24  
24  
24  
24  
38  
34  
42  
36  
(16)5-20R  
3.4  
NA  
2U  
L6-30P  
(12)C13,  
(12)C13,  
(16)5-20R  
(16)5-20R  
(16)5-20R  
(20)C13,  
(20)C13,  
(24)5-20R  
(20)C13,  
(20)C13,  
(32)C13,  
(28)C13,  
(36)C13,  
(30)C13,  
(4)C19  
3.4  
INTL  
NA  
2U  
IEC 60309-332P6  
5-15P  
(4)C19  
3.4  
0U HALF  
0U HALF  
0U HALF  
0U MID  
0U MID  
0U MID  
0U MID  
0U Mid  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
32.2  
32.2  
32.2  
58.7  
58.7  
58.7  
58.7  
58.7  
68.9  
68.9  
68.9  
68.9  
NA  
5-20P  
2.0  
2.1  
NA  
L5-20P  
2.0  
2.1  
INTL  
NA  
IEC 60309-316P6  
L6-20P  
(4)C19  
(4)C19  
2.0  
2.1  
2.0  
2.1  
NA  
L5-30P  
2.0  
2.1  
NA  
L6-30P  
(4)C19  
(4)C19  
(6)C19  
(6)C19  
(6)C19  
(6)C19  
2.0  
2.1  
INTL  
NA  
IEC 60309-332P6  
L6-30P  
2.0  
2.1  
2.0  
2.1  
INTL  
INTL  
NA  
IEC 60309-332P6  
IEC 60309-332P6  
CS8265C  
2.0  
2.1  
2.0  
2.1  
2.0  
2.1  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
50  
60  
30  
30  
1U  
1U  
L15-30P  
L21-30P  
3
3
6
6
3
3
8.6  
8.6  
6
6
(6)C19  
(6)C19  
(6)C19  
(6)C19  
(18)C13,  
(18)C13,  
1.7  
1.7  
17.5  
17.5  
17.5  
17.5  
2.0  
10.6  
10.6  
10.6  
10.6  
2.1  
P06D16M  
P06D17M  
P06D18M  
P06D19M  
P24D27M  
P24D01M  
1U  
CS8365C  
14.4  
17.3  
8.6  
6
1.7  
1U  
IEC 60309-460P9  
L15-30P  
6
1.7  
0U MID  
0U MID  
24  
24  
(6)C19  
58.7  
58.7  
L21-30P  
8.6  
(6)C19  
(6)C19,  
2.0  
2.1  
(18)C13,  
(6)5-20R  
NA  
NA  
NA  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
L21-30P  
L15-30P  
L21-30P  
3
3
3
8.6  
8.6  
8.6  
30  
36  
38  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
P30D02M  
P36D08M  
P38D28M  
(30)C13,  
(6)C19  
(6)C19,  
(30)C13,  
(2)5-20R  
NA  
NA  
NA  
50  
50  
60  
0U FULL  
0U FULL  
0U FULL  
CS8365C  
CS8365C  
3
6
6
10.0  
14.4  
17.3  
36  
24  
24  
(30)C13,  
(12)C13,  
(12)C13,  
(6)C19  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
P36D29M  
P24D31M  
P24D34M  
(12)C19  
(12)C19  
IEC 60309-460P9  
0U HALF -  
2 sided  
NA  
NA  
NA  
50  
60  
50  
CS8365C  
IEC 60309-460P9  
CS8365C  
6
6
6
14.4  
17.3  
14.4  
24  
24  
48  
(18)C13,  
(18)C13,  
(36)C13,  
(6)C19  
(6)C19  
(12)C19  
36.0  
36.0  
71.7  
2.0  
2.0  
2.0  
4.4  
4.4  
4.4  
P24D30M  
P24D33M  
P48D32M  
0U HALF -  
2 sided  
0U FULL -  
2 sided  
0U FULL -  
2 sided  
NA  
60  
IEC 60309-460P9  
6
17.3  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48D35M  
INTL  
INTL  
INTL  
INTL  
INTL  
INTL  
16  
32  
16  
16  
32  
32  
1U  
IEC 60309-516P6  
IEC 60309-532P6  
IEC 60309-516P6  
IEC 60309-516P6  
IEC 60309-532P6  
IEC 60309-532P6  
0
6
0
0
6
6
11.0  
22.0  
11.0  
11.0  
22.0  
22.0  
6
(6)C19  
1.7  
1.7  
17.5  
17.5  
2.0  
10.6  
10.6  
2.1  
P06D38M  
P06D39M  
P30D05M  
P42D42M  
P24D43M  
P42D04M  
1U  
6
(6)C19  
0U MID  
0U FULL  
0U FULL  
0U FULL  
30  
42  
24  
42  
(24)C13,  
(36)C13,  
(12)C13,  
(30)C13,  
(6)C19  
(6)C19  
(12)C19  
(12)C19  
58.7  
68.9  
68.9  
68.9  
2.0  
2.1  
2.0  
2.1  
2.2  
2.1  
0U FULL -  
2 sided  
INTL  
32  
IEC 60309-532P6  
6
22.0  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48D44M  
(continued pg. 5)  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Input - MI Series (continued)  
Input  
Apparent  
Power  
(kVA)  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
Outlet Configuration  
(inches) (inches)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
NA  
30  
1U  
6
17.3  
6
(6)C19  
1.7  
17.5  
10.6  
P06D01M  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
NA  
NA  
NA  
30  
30  
30  
1U  
1U  
6
6
6
17.3  
17.3  
17.3  
6
6
(6)C19  
(6)C19  
1.7  
1.7  
17.5  
17.5  
2.0  
10.6  
10.6  
2.1  
P06D03M  
P06D02M  
P24D02M  
NEMA L22-30P  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
0U FULL  
24  
(12)C13,  
(12)C19  
68.9  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
NA  
NA  
NA  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
6
6
6
17.3  
17.3  
17.3  
24  
24  
36  
(12)C13,  
(12)C13,  
(24)C13,  
(12)C19  
(12)C19  
(12)C19  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
P24D05M  
P24D04M  
P36D01M  
NEMA L22-30P  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
NA  
NA  
NA  
30  
30  
30  
0U FULL  
0U FULL  
6
6
6
17.3  
17.3  
17.3  
36  
36  
48  
(24)C13,  
(24)C13,  
(36)C13,  
(12)C19  
(12)C19  
(12)C19  
68.9  
68.9  
71.7  
2.0  
2.0  
2.0  
2.1  
2.1  
4.4  
P36D03M  
P36D02M  
P48D01M  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
30  
6
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
48  
48  
48  
48  
48  
42  
42  
42  
(36)C13,  
(36)C13,  
(48)C13  
(48)C13  
(48)C13  
(36)C13,  
(36)C13,  
(36)C13,  
(12)C19  
(12)C19  
71.7  
71.7  
68.9  
68.9  
68.9  
74.6  
74.6  
74.6  
2.0  
2.0  
3.3  
3.3  
3.3  
2.0  
2.0  
2.0  
4.4  
4.4  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P48D07M  
P48D02M  
P48D03M  
P48D04M  
P48D08M  
P42D05M  
P42D07M  
P42D08M  
2 sided  
(IP44)  
0U FULL -  
2 sided  
NEMA L22-30P  
0U FULL -  
Wide  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide  
(IP44)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
0U FULL +  
(6)C19  
(6)C19  
(6)C19  
0U FULL +  
0U FULL +  
NEMA L22-30P  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
Note: MOQ 80 & LT 20 Business Days applies for all 415V PDUs for N. America. All 415V PDUs for N. America include 10 kAIC circuit breakers.  
Monitored Switched - MS Series  
Input  
Apparent  
Power  
(kVA)  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
Outlet Configuration  
(inches) (inches)  
NA  
INTL  
NA  
15  
16  
20  
20  
20  
32  
30  
30  
32  
15  
16  
20  
20  
20  
16  
30  
30  
30  
32  
32  
32  
1U  
1U  
5-15P  
0
0
0
0
0
2
2
2
2
0
0
0
0
0
0
2
2
2
2
2
2
1.4  
3.7  
1.9  
1.9  
3.3  
7.4  
2.9  
5.0  
7.4  
1.4  
3.7  
1.9  
1.9  
3.3  
3.7  
2.9  
5.0  
5.0  
7.4  
7.4  
7.4  
8
(8)5-20R  
1.7  
1.7  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
17.5  
2.0  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
10.6  
2.1  
P08E14M  
P08E25M  
P08E15M  
P08E16M  
P08E18M  
P08E05M  
P16E17M  
P16E19M  
P16E26M  
P12E20M  
P16E27M  
P12E21M  
P12E22M  
P16E24M  
P24E04M  
P18E23M  
P24E28M  
P36E33M  
P24E01M  
P32E06M  
P44E07M  
IEC 60309-316P6  
5-20P  
8
(8)C13  
1U  
8
(8)5-20R  
(8)5-20R  
(8)C13  
1.7  
NA  
1U  
L5-20P  
8
1.7  
NA  
1U  
L6-20P  
8
1.7  
INTL  
NA  
1U  
IEC 60309-332P6  
L5-30P  
8
(8)C13  
1.7  
2U  
16  
16  
16  
12  
16  
12  
12  
16  
24  
18  
24  
36  
24  
32  
44  
(16)5-20R  
3.4  
NA  
2U  
L6-30P  
(12)C13,  
(12)C13,  
(12)5-20R  
(12)C13,  
(12)5-20R  
(12)5-20R  
(12)C13,  
(20)C13,  
(18)5-20R  
(20)C13,  
(30)C13,  
(20)C13,  
(24)C13,  
(38)C13,  
(4)C19  
3.4  
INTL  
NA  
2U  
IEC 60309-332P6  
5-15P  
(4)C19  
3.4  
0U HALF  
0U HALF  
0U HALF  
0U HALF  
0U HALF  
0U MID  
0U MID  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
36.1  
36.1  
36.1  
36.1  
36.1  
58.7  
58.7  
68.9  
68.9  
68.9  
68.9  
68.9  
INTL  
NA  
IEC 60309-316P6  
5-20P  
(4)C19  
2.0  
2.1  
2.0  
2.1  
NA  
L5-20P  
2.0  
2.1  
NA  
L6-20P  
(4)C19  
(4)C19  
2.0  
2.1  
INTL  
NA  
IEC 60309-316P6  
L5-30P  
2.0  
2.1  
2.0  
2.1  
NA  
L6-30P  
(4)C19  
(6)C19  
(4)C19  
(8)C19  
(6)C19  
2.0  
2.1  
NA  
L6-30P  
2.0  
2.1  
INTL  
INTL  
INTL  
IEC 60309-332P6  
IEC 60309-332P6  
IEC 60309-332P6  
2.0  
2.1  
2.0  
2.1  
0U FULL -  
wide  
3.3  
2.1  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Switched - MS Series  
Input  
Apparent  
Power  
(kVA)  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
Outlet Configuration  
(inches) (inches)  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
50  
50  
60  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
L15-30P  
3
3
3
3
6
3
6
8.6  
8.6  
24  
24  
36  
36  
24  
36  
24  
(18)C13,  
(18)C13,  
(30)C13,  
(30)C13,  
(12)C13,  
(30)C13,  
(12)C13,  
(6)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P24E29M  
P24E30M  
P36E34M  
P36E35M  
P24E31M  
P36E12M  
P24E32M  
L21-30P  
L15-30P  
(6)C19  
(6)C19  
(6)C19  
(12)C19  
(6)C19  
(12)C19  
8.6  
L21-30P  
8.6  
CS8365C  
14.4  
10.0  
17.3  
CS8365C  
IEC 60309-460P9  
0U FULL -  
2 sided  
NA  
60  
IEC 60309-460P9  
6
17.3  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48E13M  
INTL  
INTL  
INTL  
INTL  
16  
16  
32  
32  
0U FULL  
0U FULL  
0U FULL  
IEC 60309-516P6  
IEC 60309-516P6  
IEC 60309-532P6  
IEC 60309-532P6  
0
0
6
6
11.0  
11.0  
22.0  
22.0  
24  
36  
24  
36  
(18)C13,  
(30)C13,  
(12)C13,  
(24)C13,  
(6)C19  
(6)C19  
(12)C19  
(12)C19  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
3.3  
2.1  
2.1  
2.1  
2.1  
P24E02M  
P36E08M  
P24E03M  
P36E09M  
0U FULL -  
wide  
0U FULL -  
2 sided  
INTL  
32  
IEC 60309-532P6  
6
22.0  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48E10M  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
24  
24  
24  
24  
24  
(12)C13,  
(18)C13,  
(24)C13  
(12)C13,  
(18)C13,  
(12)C19  
(6)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
P24E05M  
P24E07M  
P24E08M  
P24E09M  
P24E10M  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(12)C19  
(6)C19  
(IP44)  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
IEC 60309 3P+N+E 6h 30A  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
24  
24  
24  
24  
36  
(24)C13  
(12)C13,  
(18)C13,  
(24)C13  
(24)C13,  
68.9  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
3.3  
2.1  
2.1  
2.1  
2.1  
2.1  
P24E11M  
P24E06M  
P24E12M  
P24E13M  
P36E01M  
(IP44)  
NEMA L22-30P  
NEMA L22-30P  
NEMA L22-30P  
(12)C19  
(6)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP44)  
(12)C19  
(6)C19  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
36  
36  
36  
36  
36  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
(30)C13,  
(24)C13,  
(30)C13,  
(24)C13,  
(30)C13,  
(36)C13,  
(48)C13  
(36)C13,  
(48)C13  
(36)C13,  
(48)C13  
(48)C13  
(48)C13  
(48)C13  
(42)C13,  
(42)C13,  
(42)C13,  
68.9  
68.9  
68.9  
68.9  
68.9  
71.7  
71.7  
71.7  
71.7  
71.7  
71.7  
74.0  
74.0  
74.0  
74.0  
74.0  
74.0  
3.3  
3.3  
3.3  
3.3  
3.3  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
2.1  
2.1  
2.1  
2.1  
2.1  
4.4  
4.4  
4.4  
4.4  
4.4  
4.4  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P36E03M  
P36E04M  
P36E05M  
P36E02M  
P36E06M  
P48E01M  
P48E07M  
P48E08M  
P48E09M  
P48E02M  
P48E14M  
P48E04M  
P48E03M  
P48E11M  
P48E05M  
P48E06M  
P48E12M  
(12)C19  
(6)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide  
0U FULL -  
Wide  
0U FULL -  
Wide  
(IP44)  
NEMA L22-30P  
(12)C19  
(6)C19  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP44)  
(12)C19  
(12)C19  
(12)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided  
0U FULL -  
2 sided  
0U FULL -  
2 sided  
0U FULL -  
Wide +  
(IP44)  
NEMA L22-30P  
NEMA L22-30P  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP44)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
(6)C19  
(6)C19  
(6)C19  
Wide +  
0U FULL -  
Wide +  
(IP67)  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP44)  
Note: MOQ 80 & LT 20 Business Days applies for all 415V PDUs for N. America. All 415V PDUs for N. America feature 10 kAIC circuit breakers.  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Per Outlet - MPO Series  
Input  
Apparent  
Power  
(kVA)  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
Outlet Configuration  
(inches) (inches)  
NA  
NA  
30  
30  
32  
32  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
NEMA L6-30P  
2
2
2
2
5.0  
5.0  
7.4  
7.4  
24  
36  
24  
32  
(20)C13,  
(30)C13,  
(20)C13,  
(24)C13,  
(4)C19  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
P24F01M  
P36F15M  
P24F06M  
P32F10M  
NEMA L6-30P  
IEC 60309-332P6  
IEC 60309-332P6  
(6)C19  
(4)C19  
(8)C19  
INTL  
INTL  
0U FULL -  
wide  
INTL  
32  
IEC 60309-332P6  
2
7.4  
44  
(38)C13,  
(6)C19  
68.9  
3.3  
2.1  
P44F11M  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
50  
50  
60  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
NEMA L15-30P  
NEMA L21-30P  
NEMA L15-30P  
NEMA L21-30P  
Hubbell CS8365C  
Hubbell CS8365C  
IEC 60309-460P9  
3
3
3
3
6
3
6
8.6  
8.6  
24  
24  
36  
36  
24  
36  
24  
(18)C13,  
(18)C13,  
(30)C13,  
(30)C13,  
(12)C13,  
(30)C13,  
(12)C13,  
(6)C19  
(6)C19  
(6)C19  
(6)C19  
(12)C19  
(6)C19  
(12)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P24F02M  
P24F03M  
P36F16M  
P36F17M  
P24F04M  
P36F18M  
P24F05M  
8.6  
8.6  
14.4  
10.0  
17.3  
0U FULL -  
2 sided  
NA  
60  
IEC 60309-460P9  
6
17.3  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48F19M  
INTL  
INTL  
INTL  
16  
16  
32  
0U FULL  
0U FULL  
0U FULL  
IEC 60309-516P6  
IEC 60309-516P6  
IEC 60309-532P6  
0
0
6
11.0  
11.0  
22.0  
24  
36  
24  
(18)C13,  
(30)C13,  
(12)C13,  
(6)C19  
(6)C19  
(12)C19  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
P24F07M  
P36F12M  
P24F08M  
0U FULL -  
wide  
0U FULL -  
2 sided  
INTL  
INTL  
32  
32  
IEC 60309-532P6  
IEC 60309-532P6  
6
6
22.0  
22.0  
36  
48  
(24)C13,  
(36)C13,  
(12)C19  
(12)C19  
68.9  
71.7  
3.3  
2.0  
2.1  
4.4  
P36F13M  
P48F09M  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
6
6
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
24  
24  
24  
24  
24  
24  
24  
24  
24  
(12)C13,  
(18)C13,  
(24)C13  
(12)C13,  
(18)C13,  
(24)C13  
(12)C13,  
(18)C13,  
(24)C13  
(12)C19  
(6)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P24F09M  
P24F11M  
P24F12M  
P24F13M  
P24F14M  
P24F15M  
P24F10M  
P24F16M  
P24F17M  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
(12)C19  
(6)C19  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
IEC 60309 3P+N+E 6h 30A  
(IP44)  
NEMA L22-30P  
NEMA L22-30P  
NEMA L22-30P  
(12)C19  
(6)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP44)  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
6
6
6
6
17.3  
17.3  
17.3  
17.3  
36  
36  
36  
36  
(24)C13,  
(30)C13,  
(24)C13,  
(30)C13,  
(12)C19  
(6)C19  
(12)C19  
(6)C19  
68.9  
68.9  
68.9  
68.9  
3.3  
3.3  
3.3  
3.3  
2.1  
2.1  
2.1  
2.1  
P36F01M  
P36F03M  
P36F04M  
P36F05M  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide  
(IP44)  
0U FULL -  
Wide  
0U FULL -  
Wide  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP44)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided  
0U FULL -  
2 sided  
0U FULL -  
2 sided  
0U FULL -  
Wide +  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP44)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide +  
0U FULL -  
Wide +  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP44)  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
NEMA L22-30P  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
36  
36  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
48  
(24)C13,  
(30)C13,  
(36)C13,  
(48)C13  
(36)C13,  
(48)C13  
(36)C13,  
(48)C13  
(48)C13  
(48)C13  
(48)C13  
(42)C13,  
(42)C13,  
(42)C13,  
(12)C19  
(6)C19  
68.9  
68.9  
71.7  
71.7  
71.7  
71.7  
71.7  
71.7  
74.0  
74.0  
74.0  
74.0  
74.0  
74.0  
3.3  
3.3  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
2.1  
2.1  
4.4  
4.4  
4.4  
4.4  
4.4  
4.4  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P36F02M  
P36F06M  
P48F01M  
P48F07M  
P48F08M  
P48F13M  
P48F02M  
P48F10M  
P48F04M  
P48F03M  
P48F11M  
P48F05M  
P48F06M  
P48F12M  
NEMA L22-30P  
(12)C19  
(12)C19  
(12)C19  
(IP44)  
NEMA L22-30P  
NEMA L22-30P  
NEMA L22-30P  
(6)C19  
(6)C19  
(6)C19  
(IP67)  
NEMA L22-30P  
Note: MOQ 80 & LT 20 Business Days applies for all 415V PDUs for N. America. All 415V PDUs for N. America feature 10 kAIC circuit breakers.  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Switched Per Outlet - MSPO Series  
Input  
Apparent  
Power  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
(kVA)  
Outlet Configuration  
(inches) (inches)  
INTL  
INTL  
INTL  
NA  
16  
32  
16  
30  
30  
32  
32  
1U  
IEC 60309-316P6  
0
2
0
2
2
2
2
3.7  
7.4  
3.7  
5.0  
5.0  
7.4  
7.4  
8
(8)C13  
1.7  
1.7  
17.5  
17.5  
2.0  
10.6  
10.6  
2.1  
P08G10M  
P08G12M  
P24G11M  
P24G01M  
P36G18M  
P24G06M  
P32G13M  
1U  
IEC 60309-332P6  
IEC 60309-316P6  
L6-30P  
8
(8)C13  
0U Mid  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
24  
24  
36  
24  
32  
(20)C13,  
(20)C13,  
(30)C13,  
(20)C13,  
(24)C13,  
(4)C19  
58.7  
68.9  
68.9  
68.9  
68.9  
(4)C19  
(6)C19  
(4)C19  
(8)C19  
2.0  
2.1  
NA  
L6-30P  
2.0  
2.1  
INTL  
INTL  
IEC 60309-332P6  
IEC 60309-332P6  
2.0  
2.1  
2.0  
2.1  
0U FULL -  
wide  
INTL  
32  
IEC 60309-332P6  
2
7.4  
44  
(38)C13,  
(6)C19  
68.9  
3.3  
2.1  
P44G14M  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
50  
50  
60  
60  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
L15-30P  
L21-30P  
3
3
3
3
6
3
6
6
8.6  
8.6  
24  
24  
36  
36  
24  
36  
24  
48  
(18)C13,  
(18)C13,  
(30)C13,  
(30)C13,  
(12)C13,  
(30)C13,  
(12)C13,  
(36)C13,  
(6)C19  
(6)C19  
(6)C19  
(6)C19  
(12)C19  
(6)C19  
(12)C19  
(12)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
71.7  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
4.4  
P24G02M  
P24G03M  
P36G22M  
P36G19M  
P24G04M  
P36G20M  
P24G05M  
P48G21M  
L15-30P  
8.6  
L21-30P  
8.6  
CS8365C  
14.4  
10.0  
17.3  
17.3  
CS8365C  
IEC 60309-460P9  
IEC 60309-460P9  
0U FULL -  
2 sided  
INTL  
INTL  
INTL  
INTL  
16  
16  
32  
32  
0U FULL  
0U FULL  
0U FULL  
IEC 60309-516P6  
IEC 60309-516P6  
IEC 60309-532P6  
IEC 60309-532P6  
0
0
6
6
11.0  
11.0  
22.0  
22.0  
24  
36  
24  
36  
(18)C13,  
(30)C13,  
(12)C13,  
(24)C13,  
(6)C19  
(6)C19  
(12)C19  
(12)C19  
68.9  
68.9  
68.9  
68.9  
2.0  
2.0  
2.0  
3.3  
2.1  
2.1  
2.1  
2.1  
P24G07M  
P36G15M  
P24G08M  
P36G16M  
0U FULL -  
wide  
0U FULL -  
2 sided  
INTL  
32  
IEC 60309-532P6  
6
22.0  
48  
(36)C13,  
(12)C19  
71.7  
2.0  
4.4  
P48G09M  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
IEC 60309 3P+N+E 6h 30A  
(IP67)  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
30  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
0U FULL  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
24  
24  
24  
24  
24  
24  
24  
24  
24  
36  
36  
36  
36  
36  
36  
48  
48  
48  
48  
48  
(12)C13,  
(18)C13,  
(24)C13  
(12)C13,  
(18)C13,  
(24)C13  
(12)C13,  
(18)C13,  
(24)C13  
(24)C13,  
(30)C13,  
(24)C13,  
(30)C13,  
(24)C13,  
(30)C13,  
(36)C13,  
(48)C13  
(36)C13,  
(48)C13  
(36)C13,  
(12)C19  
(6)C19  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
68.9  
71.7  
71.7  
71.7  
71.7  
71.7  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
2.0  
2.0  
2.0  
2.0  
2.0  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
4.4  
4.4  
4.4  
4.4  
4.4  
P24G09M  
P24G13M  
P24G14M  
P24G15M  
P24G16M  
P24G17M  
P24G10M  
P24G18M  
P24G19M  
P36G01M  
P36G03M  
P36G04M  
P36G05M  
P36G02M  
P36G06M  
P48G01M  
P48G07M  
P48G08M  
P48G10M  
P48G02M  
(12)C19  
(6)C19  
NEMA L22-30P  
NEMA L22-30P  
NEMA L22-30P  
(12)C19  
(6)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide (IP44)  
(12)C19  
(6)C19  
(12)C19  
(6)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide  
0U FULL -  
Wide  
0U FULL -  
Wide  
(IP44)  
NEMA L22-30P  
(12)C19  
(6)C19  
NEMA L22-30P  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP67)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided (IP44)  
(12)C19  
(12)C19  
(12)C19  
0U FULL - IEC 60309 3P+N+E 6h 30A  
2 sided  
0U FULL -  
2 sided  
(IP44)  
NEMA L22-30P  
(continued pg. 9)  
SmartZoneG5 Intelligent Power Distribution Units (iPDUs)  
Monitored Switched Per Outlet - MSPO Series (continued)  
Input  
Apparent  
Power  
Depth (inches)  
at Outlet  
position  
Panduit  
SKU Part  
No.  
Current  
Circuit  
Breakers  
Outlet  
Count  
Length  
Width  
Region per phase Form Factor  
Input Plug Type  
(kVA)  
Outlet Configuration  
(inches) (inches)  
0U FULL -  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
30  
30  
30  
30  
30  
30  
30  
NEMA L22-30P  
6
6
6
6
6
6
6
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
17.3  
48  
48  
48  
48  
48  
48  
48  
(48)C13  
71.7  
74.0  
74.0  
74.0  
74.0  
74.0  
74.0  
2.0  
3.3  
3.3  
3.3  
3.3  
3.3  
3.3  
4.4  
2.1  
2.1  
2.1  
2.1  
2.1  
2.1  
P48G11M  
P48G03M  
P48G04M  
P48G12M  
P48G05M  
P48G06M  
P48G13M  
2 sided  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide +  
0U FULL -  
Wide +  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP44)  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide +  
0U FULL -  
Wide +  
0U FULL - IEC 60309 3P+N+E 6h 30A  
Wide + (IP67)  
(48)C13  
(IP67)  
NEMA L22-30P  
(48)C13  
(48)C13  
(42)C13, (6)C19  
(42)C13, (6)C19  
(42)C13, (6)C19  
(IP67)  
NEMA L22-30P  
Note: MOQ 80 & LT 20 Business Days applies for all 415V PDUs for N. America. All 415V PDUs for N. America feature 10 kAIC circuit breakers.  
WORLDWIDE SUBSIDIARIES AND SALES OFFICES  
PANDUIT US/CANADA  
Phone:  
PANDUIT EUROPE LTD.  
London, UK  
cs-emea@panduit.com  
Phone: 44.20.8601.7200  
PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN  
PANDUIT LATIN AMERICA  
Guadalajara, Mexico  
PANDUIT AUSTRALIA PTY. LTD.  
Victoria, Australia  
Republic of Singapore  
cs-ap@panduit.com  
Phone: 65.6305.7575  
Tokyo, Japan  
800.777.3300  
cs-japan@panduit.com  
Phone: 81.3.6863.6000  
cs-la@panduit.com  
cs-aus@panduit.com  
Phone: 52.33.3777.6000  
Phone: 61.3.9794.9020  
For a copy of Panduit product warranties, log on to www.panduit.com/warranty  
For more information  
Visit us at www.panduit.com  
©2019 Panduit Corp.  
ALL RIGHTS RESERVED.  
Contact Technical Support by email: techsupport@panduit.com  
or by phone: (866) 405-6654  
PUSP28--SA-ENG  
3/2019  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY