2700356 [PHOENIX]
Power/Signal Relay,;型号: | 2700356 |
厂家: | PHOENIX CONTACT |
描述: | Power/Signal Relay, 继电器 |
文件: | 总6页 (文件大小:89K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Coupling relay for SIL 3 high and low-demand applications, couples digital output signals to the I/O, 1
enabling current path, 1 confirmation current path, 1 digital signal output, safe state off applications, test pulse
filter, fixed screw terminal block
Your advantages
Up to SIL 3 according to IEC 61508
Forcibly guided contacts according to EN 50205
Easy proof test according to IEC 61508 thanks to integrated signal contact
Approved for Class I, Zone 2 applications
Low housing width of just 6.8 mm
Long service life thanks to filtering of controller test pulses
1 enabling current path, 1 digital signal output, 1 diagnostic current path
Couples digital output signals from failsafe controllers to I/O devices (valves, etc.) for electrical isolation and power adaptation
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356912891
Technical data
Note
EMC: class A product, see manufacturer's declaration in the download
area
Utilization restriction
Dimensions
Width
Height
Depth
6.8 mm
93.1 mm
102.5 mm
Ambient conditions
03/13/2019 Page 1 / 6
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Technical data
Ambient conditions
Ambient temperature (operation)
-40 °C ... 70 °C (observe derating)
-40 °C ... 85 °C
Ambient temperature (storage/transport)
Max. permissible relative humidity (operation)
Max. permissible humidity (storage/transport)
Maximum altitude
75 % (on average, 85% infrequently, non-condensing)
75 % (on average, 85% infrequently, non-condensing)
≤ 2000 m (Above sea level)
Power supply
Rated control circuit supply voltage US
24 V DC -15 % / +10 % (A1/A2)
20.4 V DC ... 26.4 V DC
Rated control supply current IS
Power consumption at US
Inrush current
typ. 45 mA
typ. 1.08 W
typ. 400 mA (Δt < 10 µs at Us)
max. 2 ms (at A1-A2; test pulse width)
≥ 100 ms (at A1-A2; test pulse rate)
24 V DC -15 % / +10 % (21/A2)
6 mA (at 21-A2 for UD; depending on load + 100 mA at M1 and 22)
typ. 2.5 A (Δt < 20 µs at UD)
Filter time
Diagnostic supply voltage UD
Input current at UD
Inrush current at UD
Serial protection against polarity reversal Suppressor diode 33 V (A1/
A2), 38 V (21/A2)
Protective circuit
Relay outputs: enabling current path
Output name
Enabling current path
2 N/O contacts in series, without delay, floating
1 (safety-related N/O contacts: 13/14)
1 enabling current path
AgSnO2
Output description
Number of outputs
Contact type
Contact material
Switching voltage
min. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
6 A (High demand)
Limiting continuous current
Inrush current
4 A (Low demand)
min. 3 mA
max. 6 A
36 A2 (observe derating)
min. 60 mW
Sq. Total current
Switching capacity
Switching frequency
max. 1 Hz
10x 106 cycles
Mechanical service life
Switching capacity according to IEC 60947-5-1
4 A (24 V (DC13))
5 A (250 V (AC15))
6 A gL/gG
Output fuse
4 A gL/gG (for low-demand applications)
Relay outputs: return current/signaling current path
03/13/2019 Page 2 / 6
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Technical data
Relay outputs: return current/signaling current path
Output name
Confirmation current path
2 N/C contacts in series, without delay, not floating (reference ground:
A2)
Output description
Number of outputs
Contact type
1 (safety-related N/C contacts: 21/22)
1 confirmation current path
AgCuNi, + Au
Contact material
Switching voltage
min. 20.4 V DC
max. 26.4 V DC
100 mA
Limiting continuous current
Inrush current
min. 1 mA
max. 100 mA
Switching capacity
Switching frequency
Mechanical service life
Output fuse
min. 20 mW
max. 1 Hz
10x 106 cycles
150 mA Fast-blow
Alarm outputs
Output description
Number of outputs
Voltage
PNP
1 (non-safety-related)
approx. 22 V DC (UD - 2 V)
max. 100 mA
Current
500 mA (Δt = 1 ms at Us)
no
Maximum inrush current
Short-circuit protection
Output fuse
150 mA fast blow
Times
< 100 ms (with Us when controlled via A1)
< 35 ms (when controlled via A1)
500 ms
Typical pickup time at US
Typical release time at US
Recovery time
General
Electromechanical relay with forcibly guided contacts in accordance with
IEC/EN 61810-3 (EN 50205)
Relay type
Nominal operating mode
Net weight
100% operating factor
83.5 g
Mounting position
vertical, horizontal, with front of module upward
Mounting type
DIN rail mounting
See derating curve
IP20
Assembly instructions
Degree of protection
Min. degree of protection of inst. location
Housing material
IP54
PBT
Housing color
yellow
Operating voltage display
1 x yellow LED
03/13/2019 Page 3 / 6
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Technical data
General
Status display
Indication
2 x green LEDs
1 x red LED
Connection data
Connection method
Screw connection
pluggable
no
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Stripping length
0.2 mm²
2.5 mm²
0.2 mm²
2.5 mm²
26
12
12 mm
M3
Screw thread
Torque
0.5 Nm ... 0.6 Nm
Safety-related characteristic data
Stop category
0
Designation
IEC 61508 - High demand
Safety Integrity Level (SIL)
Designation
3
IEC 61508 - Low demand
Safety Integrity Level (SIL)
Designation
3
EN 50156
3
Safety Integrity Level (SIL)
Standards and Regulations
Designation
Air clearances and creepage distances between the power circuits
Standards/regulations
Rated insulation voltage
DIN EN 50178, EN 60079-15
250 V AC
Safe isolation, 6 kV reinforced insulation from control circuit, start circuit,
confirmation current path, signal output to the enabling current path; 4
kV/basic insulation between all current paths and housing
Rated surge voltage/insulation
Degree of pollution
Overvoltage category
Shock
2
III
15g
Vibration (operation)
Conformance
10 Hz ...150 Hz, 2g
CE-compliant
UL, USA/Canada
cULus
Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X
Class I, Div. 2, Groups A, B, C, D, T4
C, EMC2
GL
Environmental simulation test
ISA-S71.04 (G3)
Environmental Product Compliance
03/13/2019 Page 4 / 6
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Technical data
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
Block diagram
Circuit diagram
24 V DC
SIS / FS-PLC
Logic
A1
21
13
I/O
24V
GND
PSR-PS20
0V DO DO DI
ERR
DGN
0 V
PWR
K1/2
K1
K2
L
24V DC
A2
M1
22
14
(
A1
13
)22
K1
K2
PSR-PS20
A2
(
(
) M1
14
)21
M
K1
24 V DC
K2
N
Approvals
Approvals
Approvals
GL / UL Listed / cUL Listed / Functional Safety / EAC / cULus Listed
Ex Approvals
Approval details
GL
http://exchange.dnv.com/tari/
11253-14 HH
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140324
03/13/2019 Page 5 / 6
https://www.phoenixcontact.com/pi/products/2700356
Coupling relay - PSR-PS20-1NO-1NC-24DC-SC - 2700356
Approvals
cUL Listed
Functional Safety
EAC
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140324
44-780-13755203
RU C-
DE.A*30.B.01082
cULus Listed
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
03/13/2019 Page 6 / 6
相关型号:
2700357
Safety Relay, Momentary, 0.045A (Coil), 24VDC (Coil), 1080mW (Coil), 250VDC (Contact), DC Input, DIN-Rail Mount,
PHOENIX
©2020 ICPDF网 联系我们和版权申明