3260050 [PHOENIX]
CONN TERM BLK FEED THRU 1/0-8AWG;型号: | 3260050 |
厂家: | PHOENIX CONTACT |
描述: | CONN TERM BLK FEED THRU 1/0-8AWG 端子和端子排 |
文件: | 总6页 (文件大小:79K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
High-current terminal block, nom. voltage: 1500 V, nominal current: 150 A, connection method: Power-Turn
connection, number of connections: 2, cross section:10 mm² - 70 mm², AWG: 8 - 2/0, width: 20 mm, color:
gray, mounting type: NS 35/15
Why buy this product
Quick and easy connection is now also possible for large conductors with the high-current terminal block
The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free
wiring of conductors with ferrules or solid conductors
The compact design enables wiring in a confined space
In addition to using the existing test connection, pick-off terminal blocks can be connected, each of which can also accommodate two test
cables
Key Commercial Data
Packing unit
10 STK
GTIN
GTIN
4046356998000
Technical data
General
Number of levels
1
Number of connections
Potentials
2
1
Nominal cross section
Color
50 mm²
gray
PA
V0
Insulating material
Flammability rating according to UL 94
Rated surge voltage
Degree of pollution
Overvoltage category
Insulating material group
8 kV
3
III
I
02/09/2018 Page 1 / 6
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Technical data
General
Maximum power dissipation for nominal condition
Maximum load current
4.73 W
150 A (with 70 mm² conductor cross section)
Nominal current IN
150 A
Nominal voltage UN
1500 V DC
1000 V AC
Open side panel
No
Shock protection test specification
Back of the hand protection
Finger protection
DIN EN 50274 (VDE 0660-514):2002-11
guaranteed
guaranteed
Test passed
9.8 kV
Result of surge voltage test
Surge voltage test setpoint
Result of power-frequency withstand voltage test
Test passed
Result of the test for mechanical stability of terminal points (5 x
conductor connection)
Test passed
Result of bending test
Test passed
10 rpm
Bending test rotation speed
Bending test turns
135
Bending test conductor cross section/weight
10 mm² / 2 kg
50 mm² / 9.5 kg
70 mm²/10.4 kg
Test passed
10 mm²
Tensile test result
Conductor cross section tensile test
Tractive force setpoint
90 N
Conductor cross section tensile test
Tractive force setpoint
50 mm²
236 N
Conductor cross section tensile test
Tractive force setpoint
70 mm²
285 N
Result of tight fit on support
Tight fit on carrier
Test passed
NS 35
Setpoint
10 N
Result of voltage-drop test
Test passed
≤ 3.2 mV
Test passed
Test passed
50 mm²
Requirements, voltage drop
Result of temperature-rise test
Short circuit stability result
Conductor cross section short circuit testing
Short-time current
6 kA
Result of thermal test
Test passed
192
Ageing test for screwless modular terminal block temperature cycles
Proof of thermal characteristics (needle flame) effective duration
Result of aging test
30 s
Test passed
Test passed
Oscillation, broadband noise test result
02/09/2018 Page 2 / 6
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Technical data
General
Test specification, oscillation, broadband noise
Test spectrum
DIN EN 50155 (VDE 0115-200):2008-03
Service life test category 2, bogie-mounted
f1 = 5 Hz to f2 = 250 Hz
Test frequency
6.12 (m/s2)2/Hz
ASD level
Acceleration
3.12 g
Test duration per axis
Test directions
5 h
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
Shock form
DIN EN 50155 (VDE 0115-200):2008-03
Half-sine
Acceleration
30g
Shock duration
18 ms
Number of shocks per direction
Test directions
3
X-, Y- and Z-axis (pos. and neg.)
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
125 °C
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
-60 °C
Test passed
V0
Oxygen index (DIN EN ISO 4589-2)
>32 %
NF F16-101, NF F10-102 Class I
2
NF F16-101, NF F10-102 Class F
2
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
passed
passed
passed
27,5 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
20 mm
Length
101 mm
105 mm
Height NS 35/15
Connection data
Connection method
Power-Turn connection
IEC 60947-7-1
10 mm²
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
70 mm²
02/09/2018 Page 3 / 6
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Technical data
Connection data
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
8
2/0
10 mm²
70 mm²
8
2/0
Conductor cross section flexible, with ferrule without plastic sleeve min. 10 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 50 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Cross section with insertion bridge solid min.
10 mm²
50 mm²
10 mm²
50 mm²
10 mm²
50 mm²
Cross section with insertion bridge, solid max.
Cross section with insertion bridge stranded min.
Cross section with insertion bridge, stranded max.
Cross section with insertion bridge stranded, with ferrule without plastic
sleeve min.
10 mm²
50 mm²
10 mm²
50 mm²
10 mm²
16 mm²
Cross section with insertion bridge stranded, with ferrule without plastic
sleeve max.
Cross section with insertion bridge stranded, with ferrule without plastic
sleeve min.
Cross section with insertion bridge stranded, with ferrule with plastic
sleeve max.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, min.
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
Cross section with insertion bridge, solid max.
Cross section with insertion bridge, stranded max.
Stripping length
50 mm²
50 mm²
30 mm
A10
Internal cylindrical gage
Standards and Regulations
Connection in acc. with standard
IEC 60947-7-1
Flammability rating according to UL 94
V0
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
02/09/2018 Page 4 / 6
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Circuit diagram
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / DNV GL / LR / BV / EAC / cULus Recognized
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services-industries/product-listing/
13631
B
C
mm²/AWG/kcmil
8-1/0
140 A
600 V
8-1/0
140 A
1000 V
Nominal current IN
Nominal voltage UN
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 60425
mm²/AWG/kcmil
8-1/0
Nominal current IN
Nominal voltage UN
140 A
1000 V
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 60425
C
mm²/AWG/kcmil
8-1/0
140 A
1000 V
Nominal current IN
Nominal voltage UN
DNV GL
http://exchange.dnv.com/tari/
TAE00000Z9
02/09/2018 Page 5 / 6
https://www.phoenixcontact.com/pi/products/3260050
High-current terminal block - PTPOWER 50 - 3260050
Approvals
LR
http://www.lr.org/en
15/20030
http://www.veristar.com/portal/veristarinfo/generalinfo/
approved/approvedProducts/equipmentAndMaterials
BV
EAC
40933/A1 BV
RU C-
DE.A*30.B.01742
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
02/09/2018 Page 6 / 6
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明