MAP80 SERIES
Power-One’s MAP80 series of power supplies provides reliable, tightly
convection cooled applications. Design innovations include metric
and SAE mounting inserts on each mounting surface to provide
integration flexibility. Dual-mode connectors provide traditional
terminal block connections or popular single row Molex connector
mating.
regulated DC power for commercial and industrial systems which
require high peak current capabilities. Wide-range AC input and full
international safety, EMI, and ESD compliance ensure world-wide
acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally
efficient U-channel chassis to provide full power operation in
Single output models feature wide-range output adjustability to meet a
wide variety of standard and user specific output voltage requirements.
FEATURES
•
•
•
•
•
•
Wide Range Input for 110/220 VAC Applications
CE Marked to Low Voltage Directive
Input Transient & ESD Compliance to EN61000-4-2/-3/-4
Meets EN55022, Class B Limits
TTL Compatible Power Fail Signal
Compact Footprint: 7.20" x 4.20" x 1.80"
(182.9mm x 106.7mm x 45.7mm)
•
•
Greater than 175,000 Hours MTBF
Metric and SAE Mounting Inserts
SINGLE OUTPUT MODEL SELECTION CHART
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT (NOTE 3)
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
MAP80-1005
MAP80-1012
MAP80-1024
5V
12V/15V
24V/28V
4.5V to 5.6V
11.5V to 15.5V
23.0V to 29.0V
16A
18A
0.2%
0.2%
0.1%
1%
1%
0.5%
1.4%
1%
0.5%
5.0V to 5.1V
11.76V to 12.15V
23.8V to 24.2V
7.5/6A (Note 2)
3.8/3.2A (Note 2)
9.2/7.3A (Note 2)
4.6/3.9A (Note 2)
NOTES: 1) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
2) MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
3) Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
MULTIPLE OUTPUT MODEL SELECTION CHART – 80W CONTINUOUS OUTPUT POWER
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
PEAK OUTPUT
LINE
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
CURRENT
CURRENT (NOTE 1)
REGULATION
+5V
+12V
-5V
-12V
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
+15V
-5V
-15V
+5V
+24V
-15V
+15V
4.8V to 5.5V
11.52V to 12.48V
Fixed
14A
4A
1A
1A
14A
2A
1A
1A
14A
4A
1A
16A
7A
1A
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.1V to 5.2V
11.9V to 12.1V
-4.8V to -5.4V
-11.5V to -12.5V
5.1V to 5.2V
24.0V to 24.1V
-11.5V to -12.5V
11.5V to 12.5V
5.1V to 5.2V
12.0V to 12.1V
-11.6V to -12.4V
11.6V to 12.4V
5.1V to 5.2V
14.6V to 15.1V
-4.8V to -5.4V
-14.4V to -15.5V
5.1V to 5.2V
MAP80-4000
Fixed
1A
4.8V to 5.5V
23.04V to 24.96V
Fixed
16A
3.5A
1A
1A
16A
7A
1A
1A
16A
6A
1A
MAP80-4001
MAP80-4002
MAP80-4003
MAP80-4004
Fixed
4.7V to 5.5V
11.52V to 12.48V
Fixed
Fixed
1A
4.8V to 5.5V
14.40V to 15.60V
Fixed
14A
3.5A
1A
1A
14A
2A
Fixed
1A
4.8V to 5.5V
23.04V to 24.96V
Fixed
16A
3.5A
1A
24.0V to 24.1V
-14.4V to -15.5V
14.4V to 15.5V
1A
1A
Fixed
1A
Rev. 04/2000
1
MAP80 SERIES
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) – 80W CONTINUOUS OUTPUT POWER
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
PEAK OUTPUT
LINE
LOAD
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
CURRENT
CURRENT (NOTE 1)
REGULATION
REGULATION
+5V
+12V
-5V
-12V
+5V
+12V
-12V
-5V
4.8V to 5.5V
11.52V to 12.48V
Fixed
14A
4A
1A
3A
14A
4A
16A
7A
1A
3A
16A
7A
0.2%
0.2%
0.5%
0.5%
0.2%
0.2%
0.5%
0.5%
1%
1%
2%
2%
1%
1%
2%
2%
1%
1%
1%
1%
1%
1%
1%
1%
5.1V to 5.2V
12.0V to 12.1V
-4.8V to -5.4V
-11.5V to -12.5V
5.1V to 5.2V
12.0V to 12.1V
-11.5V to -12.5V
-4.8V to -5.4V
MAP80-4010
Fixed
4.8V to 5.5V
11.52V to 12.48V
Fixed
MAP80-4020
1A
3A
1A
3A
Fixed
NOTES: 1) Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth.
INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range.
90
175
135
264
VAC
Input Frequency
Brown Out Protection
Hold-up Time
AC input.
47
90
20
63
Hz
VAC
mS
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (115VAC), full rated load.
Input Current
90 VAC (80W load).
110VAC (80W load).
2.5
2.8
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
45
APK
kHz
Operating Frequency
Switching frequency of power supply (varies with load).
22
120
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load, 115VAC. Varies with distribution of loads among outputs.
73
75
80
%
Minimum Loads
MAP80-1012
MAP80-1024
0.42
0.21
1.00
Amps
MAP80-1005 and all multiple output models, main channel only.
Ripple and Noise
Output Power
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
See Model Selection Chart.
80
90
Watts
Watts
Overshoot / Undershoot
Regulation
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC
or 175-264, changes in load starting at 20% load and changing to 100% load.
1
%
See Model Selection Chart.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
500
µS
Turn-On Delay
Turn-on Rise Time
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
1
5
20
Sec
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage
Protection
Provided on MAP80-1005 and the main output of multiple output units.
5.5
17
32
6.8
23
37
MAP80-1012
MAP80-1024
V
Overload Protection
Power Fail
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
TTL compatible logic signal. Time before regulation dropout
Warning (Note 1)
due to loss of input power at 110VAC.
4
mS
NOTES: 1) Power Fail Warning is not available on MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
2
MAP80 SERIES
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Approved
Dielectric Withstand
Voltage
Input to output.
2600
VDC
Electromagnetic
Interference,
Conducted
Input Transient
Protection
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
B
B
B
Class
kV
EN61000-4-5 level 3.
Line to line
Line to ground
1
2
Insulation Resistance
Leakage Current
Input to output.
Per EN60950, 264VAC.
7
MΩ
µA
500
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-operating.
10k
40k
ASL Ft.
ASL Ft.
Operating Temperature
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C.
At 100% load:
At 50% load:
0
0
50
70
°C
°C
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
-55
85
0.03
95
20
6
°C
%/°C
%RH
G
0°C to 70°C (After 15 minute warm-up).
Non-condensing.
Operating, peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
0.02
5
Vibration
GRMS
OPTIONS
DESCRIPTION
Cover
NOTES
SIZE IMPACT
Add ‘C’ suffix to model number or order part number 412-59585 separately.
For convection cooled applications, derate output power to 65 watts on all multiple
output models and MAP80-1005. Derate MAP80-1012 and MAP80-1024 to 75 watts.
7.20" x 4.20" x 2.05"
(183.0mm x 107.0mm x 52.0mm)
For the Most Up-To-Date Information
www.power-one.com
24 Hours/Day—7 Days/Week
3
MAP80 SERIES
OVERALL SIZE: 7.20" x 4.20" x 1.80" (182.9mm x 106.7mm x 45.7mm)
WEIGHT: 1.8 LBS (0.82 kg)
TB1
TB2
1
3
1
4.20"
(106.7mm)
F1
2.170"
(55.1mm)
3
2.626"
(66.70mm)
3.230"
(82.0mm)
V2
V. ADJ.
7
COM
1.02"
(25.8mm)
J1
V1
V. ADJ.
0.79"
(20.0mm)
PF
0. 485"
(12.3mm)
7. 7.20" (182.9mm)
6.70" (170.2mm)
0.25"
(6.4mm)
1.80"
(45.7mm)
1.04"
(26.4mm)
0.81"
(20.6mm)
0.51"
(13.0mm)
TB1
TB2
6-32 UNC – 2B
THREAD
PIN 1
PIN 1
UNIVERSAL
MOUNTING
INSERT
AC INPUT
(MATES WITH
5 CIRCUIT
DC OUTPUT
M4 x 0.7 – 6H
THREAD
(MATES WITH
14 CIRCUIT
MOLEX
(8 PLACES)
MOLEX
CONNECTOR)
CONNECTOR)
COM
GND
N
L
V1 V1
V2 V3 V4
0.17" (4.3mm)
DIA THRU
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW WIRE CLAMPS ON 0.312" (7.9mm) CENTERS, 0.045" (1.1mm)
SQUARE PINS ON 0.156" (3.9mm) CENTERS, MATES WITH MOLEX SERIES 2139, 6442, OR 41695
POWER FAIL CONNECTIONS: J1: 0.035" (0.9mm) SQUARE PINS ON 0.100" (2.5mm) CENTERS, MATES WITH MOLEX SERIES 2695/6471
CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH
4
相关型号:
©2020 ICPDF网 联系我们和版权申明