Product Overview
Qorvo's QPA2612 is a packaged, high performance power
amplifier fabricated on Qorvo's production 0.15 um GaN on
SiC process (QGaN15). Covering 8ꢀ-ꢀ12 GHz, the QPA2612
provides > 12 W of saturated output power and 23 dB of
large-signal gain while achieving an impressive 40%
power-added efficiency.
5 mm x 5 mm plastic overmold QFN
Packaged in a small 5 x 5 mm plastic overmold QFN, tight
lattice spacing requirements for phased array radar
applications is easily supported. RF input and output ports
are matched to 50Ω and are DC grounded. QPA2612 is
part of a three-amplifier family and is pin compatible to
QPA2610 and QPA2611.
Key Features
• Frequency Range: 8.0 – 12.0 GHz
• Output Power (PIN = 18 dBm): > 41 dBm
• PAE (PIN = 18 dBm): > 40 %
• Small Signal Gain: 34 dB
Lead-free and RoHS compliant.
• Input Return Loss: > 16 dB
• Output Return Loss: > 4 dB
• Recommended Bias: VD = 24 V, IDQ = 250 mA
• Package Size: 5.0 mm x 5.0 mm x 0.85 mm
Applications
Functional Block Diagram
• Radar
• Communications
• Satcom
VG
VD
RF IN
RF OUT
Ordering Information
Part No.
Description
QPA2612
12 Watt X-Band Power Amplifier
250 pcs. on 7 inch reel
QPA2612 Evaluation Board
QPA2612TR7
QPA2612EVB
Top View
Data Sheet Rev. A, November 2019
1 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Rating
29.5 V
Parameter
Typ
Drain Voltage (VD)
Drain Voltage (VD)
24 V
Gate Voltage Range (VG)
Drain Current (ID)
−4 to 0 V
1700 mA
See plot pg. 16
26.8 W
Drain Current (IDQ
)
250 mA
Drain Current Under RF Drive (ID_DRIVE
)
See plots pg. 4
−2.8 to −2.0 V
See plots pg. 4
Gate Current (IG)
Gate Voltage Range (VG)
Power Dissipation (PDISS), CW, 85 °C
Input Power (PIN), CW, 50 Ω, 85 °C
Gate Current Under RF Drive (IG_DRIVE)
Electrical specifications are measured at specified test conditions.
Specifications are not guaranteed over all recommended operating
conditions.
21 dBm
Input Power (PIN), CW, VSWR 4:1,
VD = 24 V, 85 °C
21 dBm
Mounting Temperature (30 seconds max.)
Storage Temperature
260 °C
−55 to 150 °C
Exceeding any one or a combination of the Absolute Maximum Rating
conditions may cause permanent damage to the device. Extended
application of Absolute Maximum Rating conditions to the device may
reduce device reliability.
Electrical Specifications
Parameter
Conditions
Min
Typ
Max
Units
GHz
dBm
%
Operational Frequency
8
12
Output Power (PIN = 18 dBm)
Power Added Efficiency (PIN = 18 dBm)
Small Signal Gain (CW)
Pulsed VD
Pulsed VD
41.7
43.5
34.2
21
dB
Input Return Loss (CW)
dB
Output Return Loss (CW)
6
dB
3RD Order IMD (PIN/Tone = 5 dBm)
POUT Temp. Coeff. (85ꢀ°C toꢀ25 °C, PIN = 18 dBm))
Sm. Sig. Gain Temp. Coefficient (85 °C toꢀ−40 °C)
Gate Leakage Current
10 MHz tone spacing
−14
dBc
dB/°C
dB/°C
mA
−0.003
−0.105
VD = 10 V, VG = −3.7 V
−5.37
Test conditions, unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Data Sheet Rev. A, November 2019
2 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, PIN = 18 dBm, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Freq. vs. Temp.
Power Added Eff. vs. Freq. vs. Temp.
44
43
42
41
40
39
38
37
36
60
55
50
45
40
35
30
25
20
15
10
-40 C
+25 C
+85 C
-40 C
+25 C
+85 C
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Output Power vs. Freq. vs. VDRAIN
Power Added Eff. vs. Freq. vs. VDRAIN
44
43
42
41
40
39
38
37
36
60
55
50
45
40
35
30
25
20
15
10
18 V
20 V
22 V
24 V
28 V
18 V
20 V
22 V
24 V
28 V
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Output Power vs. Freq. vs. IDQ
Power Added Eff. vs. Freq. vs. IDQ
44
43
42
41
40
39
38
37
36
60
55
50
45
40
35
30
25
20
15
10
125 mA
250 mA
500 mA
125 mA
250 mA
500 mA
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Data Sheet Rev. A, November 2019
3 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, PIN = 18 dBm, Pulse Width = 100 us, Duty Cycle = 10%
Drain Current vs. Freq. vs. Temp.
Gate Current vs. Freq. vs. Temp.
1700
1600
1500
1400
1300
1200
1100
1000
900
8
7
6
5
4
3
2
1
0
800
-1
-2
-40 C
+25 C
+85 C
-40 C
+25 C
+85 C
700
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Drain Current vs. Freq. vs. VDRAIN
Gate Current vs. Freq. vs. VDRAIN
1700
1600
1500
1400
1300
1200
1100
1000
900
8
7
6
5
4
3
2
1
0
800
-1
-2
18 V
20 V
22 V
24 V
28 V
18 V
20 V
22 V
24 V
28 V
700
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Drain Current vs. Freq. vs. IDQ
Gate Current vs. Freq. vs. IDQ
1700
1600
1500
1400
1300
1200
1100
1000
900
8
7
6
5
4
3
2
1
0
800
-1
-2
125 mA
250 mA
500 mA
125 mA
250 mA
500 mA
700
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
Data Sheet Rev. A, November 2019
4 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. PIN vs. Freq.
Power Added Eff. vs. PIN vs. Freq.
44
42
40
38
36
34
32
30
28
26
24
60
50
40
30
20
10
0
8 GHz
8 GHz
9 GHz
9 GHz
10 GHz
11 GHz
12 GHz
10 GHz
11 GHz
12 GHz
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. PIN vs. Freq.
Gate Current vs. PIN vs. Freq.
8 GHz
1700
1500
1300
1100
900
8
7
9 GHz
6
10 GHz
11 GHz
12 GHz
5
4
3
8 GHz
2
700
9 GHz
1
500
10 GHz
11 GHz
12 GHz
0
300
-1
-2
100
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Data Sheet Rev. A, November 2019
5 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Input Power vs. Temp.
10 GHz
Output Power vs. Input Power vs. Temp.
8 GHz
44
42
40
38
36
34
32
30
28
26
24
44
42
40
38
36
34
32
30
28
26
24
-40 C
6
+25 C
+85 C
-40 C
6
+25 C
+85 C
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
PAE vs. Input Power vs. Temp.
PAE vs. Input Power vs. Temp.
10 GHz
60
50
40
30
20
10
0
60
50
40
30
20
10
0
8 GHz
-40 C
+25 C
+85 C
-40 C
6
+25 C
+85 C
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. Input Power vs. Temp.
Drain Current vs. Input Power vs. Temp.
10 GHz
1700
1500
1300
1100
900
1700
1500
1300
1100
900
8 GHz
700
700
500
500
300
300
-40 C
6
+25 C
+85 C
-40 C
6
+25 C
+85 C
100
100
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Data Sheet Rev. A, November 2019
6 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Input Power vs. Temp.
12 GHz
PAE vs. Input Power vs. Temp.
12 GHz
44
42
40
38
36
34
32
30
28
26
24
60
50
40
30
20
10
0
-40 C
6
+25 C
+85 C
-40 C
+25 C
+85 C
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. Input Power vs. Temp.
1700
1500
1300
1100
900
12 GHz
700
500
300
-40 C
8
+25 C
+85 C
100
-2
0
2
4
6
10 12 14 16 18 20
Input Power (dBm)
Data Sheet Rev. A, November 2019
7 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Input Power vs. VDRAIN
8 GHz
Output Power vs. Input Power vs. VDRAIN
10 GHz
44
42
40
38
36
34
32
30
28
26
24
44
42
40
38
36
34
32
30
28
26
24
18V
20V
6
22V
24V
28V
18V
20V
6
22V
24V
28V
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
PAE vs. Input Power vs. VDRAIN
PAE vs. Input Power vs. VDRAIN
60
50
40
30
20
10
0
60
50
40
30
20
10
0
8 GHz
10 GHz
18V
20V
6
22V
24V
28V
18V
20V
6
22V
24V
28V
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. Input Power vs. VDRAIN
8 GHz
Drain Current vs. Input Power vs. VDRAIN
10 GHz
1700
1500
1300
1100
900
1700
1500
1300
1100
900
700
700
500
500
300
300
18V
20V
6
22V
24V
28V
18V
20V
6
22V
24V
28V
100
100
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Data Sheet Rev. A, November 2019
8 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Input Power vs. VDRAIN
12 GHz
PAE vs. Input Power vs. VDRAIN
44
42
40
38
36
34
32
30
28
26
24
60
50
40
30
20
10
0
12 GHz
18V
20V
6
22V
24V
28V
18V
20V
6
22V
24V
28V
-2
0
2
4
8
10 12 14 16 18 20
-2
0
2
4
8 10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Output Power vs. Input Power vs. VDRAIN
12 GHz
1700
1500
1300
1100
900
700
500
300
18V
2
20V
6
22V
24V
28V
100
-2
0
4
8 10 12 14 16 18 20
Input Power (dBm)
Data Sheet Rev. A, November 2019
9 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
Output Power vs. Input Power vs. IDQ
10 GHz
Output Power vs. Input Power vs. IDQ
8 GHz
44
42
40
38
36
34
32
30
28
26
24
44
42
40
38
36
34
32
30
28
26
24
125mA
250mA
500mA
125mA
250mA
500mA
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
PAE vs. Input Power vs. IDQ
PAE vs. Input Power vs. IDQ
60
50
40
30
20
10
0
60
50
40
30
20
10
0
8 GHz
10 GHz
125mA
250mA
500mA
125mA
250mA
500mA
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. Input Power vs. IDQ
10 GHz
Drain Current vs. Input Power vs. IDQ
8 GHz
1700
1500
1300
1100
900
1700
1500
1300
1100
900
700
700
500
500
300
300
125mA
250mA
500mA
125mA
250mA
500mA
100
100
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Data Sheet Rev. A, November 2019
10 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Large Signal (Pulsed)
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
PAE vs. Input Power vs. IDQ
Output Power vs. Input Power vs. IDQ
12 GHz
44
42
40
38
36
34
32
30
28
26
24
60
50
40
30
20
10
0
12 GHz
125mA
250mA
500mA
125mA
250mA
500mA
-2
0
2
4
6
8
10 12 14 16 18 20
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Drain Current vs. Input Power vs. IDQ
12 GHz
1700
1500
1300
1100
900
700
500
300
125mA
250mA
500mA
100
-2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Data Sheet Rev. A, November 2019
11 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Linearity
Test conditions unless otherwise noted: VD = 24 V, IDQ = 250 mA, T = 25 °C, 10 MHz Tone Spacing, CW
IMD3, IMD5 vs. PIN/Tone vs. Temp.
Fc = 8.5 GHz
IMD3, IMD5 vs. PIN/Tone vs. Temp.
Fc = 10.5 GHz
0
-10
-20
-30
-40
-50
-60
0
-10
-20
-30
-40
-50
-60
IM3 -40 C
IM5 -40 C
IM3 25 C
IM5 25 C
IM3 85 C
IM5 85 C
IM3 -40 C
IM5 -40 C
IM3 25 C
IM5 25 C
IM3 85 C
IM5 85 C
-10.0 -7.5 -5.0 -2.5 0.0 2.5 5.0 7.5 10.0 12.5 15.0
Input Power / Tone (dBm)
-10.0 -7.5 -5.0 -2.5 0.0 2.5 5.0 7.5 10.0 12.5 15.0
Input Power / Tone (dBm)
IMD3, IMD5 vs. PIN/Tone vs. Temp.
Fc = 11.5 GHz
0
-10
-20
-30
-40
-50
-60
IM3 -40 C
IM5 -40 C
IM3 25 C
IM5 25 C
IM3 85 C
IM5 85 C
-10.0 -7.5 -5.0 -2.5 0.0 2.5 5.0 7.5 10.0 12.5 15.0
Input Power / Tone (dBm)
Data Sheet Rev. A, November 2019
12 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Harmonics
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, Pulse Width = 100 us, Duty Cycle = 10%
2nd Harmonic vs. Fund. Freq. vs. Temp.
3rd Harmonic vs. Fund. Freq. vs. Temp.
0
-10
-20
-30
-40
-50
-60
-10
-20
-30
-40
-50
-60
-70
VD = 24 V, IDQ = 250 mA, Pin = 18 dBm
VD = 24 V, IDQ = 250 mA, Pin = 18 dBm
-40C
+25C
+85C
-40C
+25C
+85C
8.0
8.5
9.0
9.5
10.0 10.5 11.0 11.5 12.0
8.0
8.5
9.0
9.5
10.0 10.5 11.0 11.5 12.0
Frequency (GHz)
Frequency (GHz)
2nd Harmonic vs. Input Power vs Freq.
3rd Harmonic vs. Input Power vs Freq.
-10
-20
-30
-40
-50
-60
-70
-30
-40
-50
-60
-70
-80
-90
VD = 24 V, IDQ = 250 mA, Temp. = 25 °C
VD = 24 V, IDQ = 250 mA, Temp. = 25 °C
8.0 GHz
10.0 GHz
12.0 GHz
8.0 GHz
10.0 GHz
12.0 GHz
-6 -4 -2
0
2
4
6
8
10 12 14 16 18 20
-6 -4 -2
0
2
4
6
8
10 12 14 16 18 20
Input Power (dBm)
Input Power (dBm)
Data Sheet Rev. A, November 2019
13 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Small Signal
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, CW
Gain vs. Frequency vs. VDRAIN
Gain vs. Freq. vs. Temp.
50
45
40
35
30
25
20
15
10
50
45
40
35
30
25
20
15
10
-40 C
9
+25 C
10
+85 C
11
18 V
20 V
22 V
24 V
7
8
12
13
13
13
7
8
9
10
11
12
13
13
13
Frequency (GHz)
Frequency (GHz)
Input RL vs. Frequency vs. VDRAIN
Input RL vs. Freq. vs. Temp.
0
0
-40 C
+25 C
+85 C
18 V
20 V
22 V
24 V
-5
-10
-15
-20
-25
-30
-5
-10
-15
-20
-25
-30
7
8
9
10
11
12
7
8
9
10
11
12
Frequency (GHz)
Frequency (GHz)
Output RL vs. Frequency vs. VDRAIN
Output RL vs. Freq. vs. Temp.
0
-5
0
-5
-10
-15
-20
-25
-30
-10
-15
-20
-25
-30
18 V
20 V
22 V
24 V
-40 C
9
+25 C
10
+85 C
11
7
8
12
7
8
9
10
11
12
Frequency (GHz)
Frequency (GHz)
Data Sheet Rev. A, November 2019
14 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Performance Plots – Small Signal
Test conditions unless otherwise noted: T = +25 °C, VD = 24 V, IDQ = 250 mA, CW
Gain vs. Frequency vs. IDQ
Input RL vs. Frequency vs. IDQ
50
45
40
35
30
25
20
15
10
0
-5
125mA
250mA
500mA
-10
-15
-20
-25
-30
125mA
9
250mA
10
500mA
11
7
8
12
13
7
8
9
10
11
12
13
Frequency (GHz)
Frequency (GHz)
Output RL vs. Frequency vs. IDQ
0
-5
-10
-15
-20
-25
125mA
9
250mA
10
500mA
11
-30
7
8
12
13
Frequency (GHz)
Data Sheet Rev. A, November 2019
15 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Thermal and Reliability Information
Parameter
Test Conditions
Value
Units
Thermal Resistance (θJC) (1)
3.563
ºC/W
Tbase = +85 °C, VD = 24 V, IDQ = 250 mA, PDISS = 6.0ꢀW
(CW, quiescent, no RF)
Channel Temperature, TCH (Under RF) (2)
106.4
°C
Thermal Resistance (θJC) (1)
2.834
148.5
ºC/W
°C
Tbase = +85 °C, VD = 24 V, IDQ = 250 mA, ID_Drive
1586 mA, POUTꢀ=ꢀ41.8 ꢀdBm, PIN = 18ꢀdBm, Freq. =
11.25ꢀGHz, PDISS = 22.4 W (Pulse: 100us/10%)
=
Channel Temperature, TCH (Under RF) (2)
Thermal Resistance (θJC) (1)
Channel Temperature, TCH (Under RF) (2)
Notes:
2.794
159.9
ºC/W
°C
Tbase = +85 °C, VD = 28 V, IDQ = 250 mA, ID_Drive
1663 mA, POUTꢀ=ꢀ42.8 dBm, PIN = 18ꢀdBm, Freq. =
11.25 GHz, PDISS = 26.8ꢀW (Pulse: 100us/10%)
=
1. Thermal resistance is referenced to the back of the package.
2. IR scan equivalent temperatures. Refer to the following document: GaN Device Channel Temperature, Thermal Resistance,
and Reliability Estimates
Power Dissipation and Maximum Gate Current
PIN = 18 dBm, Pulse Width = 100 us, Duty Cycle = 10%
QPA2612 Ig_max vs. Tch
Dissipated Power vs. Freq. vs. VDRAIN
60
50
40
30
20
10
0
30
25
20
15
10
5
Total Ig_max
18V 85C
24V 85C
20V 85C
28V 85C
22V 85C
0
7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5
Frequency (GHz)
110
120
130
140
150
160
170
180
Channel Temperature (°C)
Data Sheet Rev. A, November 2019
16 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Application Information
R4, C4
NOT USED FOR
PULSED OPERATION
Bias-up Procedure
Bias-down Procedure
Set ID limit to 1800 mA, IG limit to 10 mA
Apply −4 V to VG
Turn off RF signal
Reduce VG to −4 V; ensure IDQ is approx. 0 mA
Set VD to 0 V
Apply +24 V to VD; ensure IDQ is approx. 0 mA
Adjust VG until IDQ = 250 mA
Turn on RF supply
Turn off VD supply
Turn off VG supply
Data Sheet Rev. A, November 2019
17 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
PinLayout
Pin Description
Pin Number
Symbol
NC
Description
1, 2, 4-15, 17-19, 21, 22, 24
No connection inside of package. Connection to PCB ground recommended
RF input. 50 Ω, DC blocked, pad connected to ground
RF output. 50 Ω, DC blocked, pad connected to ground
Drain voltage. Bypass network required; refer to page 19
Gate voltage. Bypass network required; refer to page 19
Center paddle ground
3
RF IN
RF OUT
VD
16
20
23
25
VG
GND
Data Sheet Rev. A, November 2019
18 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Evaluation Board
C1
R1
C2
C5
R2
C3
R5
C6
Bill of Materials
Ref. Des.
C1
Value
10 uF
1000 pF
0.1 uF
10 Ω
Description
Manuf.
various
Part Number
CAP, 10uF, 20%, 50V, 20%, X5R, 1206
CAP, 1000pF, 10%, 100V, X7R, 0402
CAP, 0.1uF, 10%, 50V, X7R, 0402
RES, 10 OHM, 5%, 0.1W, 0402
C3,C6
C2,C5
R2,R5
R1
various
various
various
0 Ω
RES, 0 OHM, JMPR, 0402
various
J1, J2
2.92mm Female End Launch Connector
Southwest Microwave
1092-01A-5
Data Sheet Rev. A, November 2019
19 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Mechanical Information
19 20 21 22 23 24
1
2
3
4
5
6
18
17
16
15
14
13
25
12 11 10
9
8
7
NOTES:
Package base and leads are Ni-Au plated
Part Markings:
Part Number: QPA2612
Part Assembly Year: YY
Part Assembly Week: WW
Lot Number: MXXX
Dimensions are in millimeters
Data Sheet Rev. A, November 2019
20 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Assembly Notes
Compatible with lead-free soldering processes with 260°C peak reflow temperature.
Contact plating: Ni-Au.
Recommended Soldering Temperature Profile
Data Sheet Rev. A, November 2019
21 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Tape and Reel Information – Carrier and Cover Tape Dimensions
Feature
Measure
Symbol
Size (in)
0.189
0.209
0.051
0.315
0.079
0.217
0.362
0.472
Size (mm)
4.80
Length
A0
B0
K0
P1
P2
F
Width
5.30
Cavity
Depth
1.30
Pitch
8.00
Cavity to Perforation - Length Direction
2.00
Centerline Distance
Cavity to Perforation - Width Direction
5.50
Cover Tape
Carrier Tape
Width
Width
C
9.20
W
12.00
Data Sheet Rev. A, November 2019
22 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Tape and Reel Information – Reel Dimensions
Standard T/R size = 500 pieces on a 7” reel.
Feature
Measure
Symbol
Size (in)
6.969
0.717
0.504
2.283
0.512
0.079
0.787
Size (mm)
177.0
18.2
Diameter
A
W2
W1
N
Flange
Thickness
Space Between Flange
Outer Diameter
Arbor Hole Diameter
Key Slit Width
Key Slit Diameter
12.8
58.0
C
13.0
Hub
B
2.0
D
20.0
Tape and Reel Information – Tape Length and Label Placement
Notes:
1. Empty part cavities at the trailing and leading ends are sealed with cover tape. See EIA 481-1-A.
2. Labels are placed on the flange opposite the sprockets in the carrier tape.
Data Sheet Rev. A, November 2019
23 of 24
www.qorvo.com
QPA2612
®
12 Watt X-Band Power Amplifier
Handling Precautions
Parameter
Rating
Standard
ESDꢀ–ꢀHuman Body Model (HBM)
1B
ESDAꢁ/ꢁJEDEC JS-001-2014
ESDAꢁ/ꢁJEDEC JS-002-2017
IPC/JEDEC J-STD-020
Caution!
ESD-Sensitive Device
ESDꢀ–ꢀCharged Device Model (CDM) C3
MSLꢀ–ꢀMoisture Sensitivity Level
3
RoHS Compliance
This part is compliant with 2011/65/EU RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and
Electronic Equipment) as amended by Directive 2015/863/EU.
This product also has the following attributes:
• Lead Free
• Halogen Free (Chlorine, Bromine)
• Antimony Free
• TBBP-A (C15H12Br402) Free
• SVHC Free
Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations:
Web: www.qorvo.com
Tel: 1-844-890-8163
Email: customer.support@qorvo.com
Important Notice
The information contained herein is believed to be reliable; however, Qorvo makes no warranties regarding the information contained
herein and assumes no responsibility or liability whatsoever for the use of the information contained herein. All information contained
herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for
Qorvo products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by
such information. THIS INFORMATION DOES NOT CONSTITUTE A WARRANTY WITH RESPECT TO THE PRODUCTS DESCRIBED
HEREIN, AND QORVO HEREBY DISCLAIMS ANY AND ALL WARRANTIES WITH RESPECT TO SUCH PRODUCTS WHETHER
EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE,
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Without limiting the generality of the foregoing, Qorvo products are not warranted or authorized for use as critical components in medical,
life-saving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal
injury or death.
Copyright 2019 © Qorvo, Inc. | Qorvo is a registered trademark of Qorvo, Inc.
Data Sheet Rev. A, November 2019
24 of 24
www.qorvo.com
相关型号:
©2020 ICPDF网 联系我们和版权申明