QPQ1297 [QORVO]

FDD Band 3 BAW Duplexer;
QPQ1297
型号: QPQ1297
厂家: Qorvo    Qorvo
描述:

FDD Band 3 BAW Duplexer

文件: 总15页 (文件大小:809K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
QPQ1297  
FDD Band 3 BAW Duplexer  
®
Product Overview  
The QPQ1297 is a high-performance Bulk Acoustic Wave  
(BAW) Duplexer designed for Bandꢁ3 uplink/downlink  
applications.  
The QPQ1297 provides low insertion loss and high rejection  
making it an ideal choice for Small Cells. This duplexer is  
housed in a compact, RoHs compliant 2.00ꢀmmꢀx2.50ꢀmm xꢀ  
0.93 mm surface mount pacakge (SMP).  
9 Pad 2.00ꢀmmꢁxꢁ2.50ꢀmmꢁxꢁ0.93ꢁmm SMP  
The QPQ1297 is part of Qorvo’s extensive portfolio of RF  
BAW and SAW filters.  
Key Features  
75MHz Bandwidth Band 3 Up Link  
75 MHz Bandwidth Band 3 Down Link  
High Attenuation  
Functional Block Diagram  
Low Loss  
GND  
No External Matching Required  
Single Input, Single Output Operation  
Small Size: 2.00mmꢁxꢁ2.50ꢀmmꢁxꢁ0.93mm  
Surface Mount Package (SMP)  
RoHS Compliant, Pb-Free  
B3 DL  
GND  
1
2
3
8
GND  
ANT  
GND  
7
6
5
9
4
GND  
Applications  
B3 UL  
Band 3  
GND  
Base Station Infrastructure  
Small Cells  
Top View  
Repeaters  
Pin Configuration  
Routers  
LTE Dongles  
Pin No.  
Label  
B3 DL  
GND  
Function  
General Purpose Wireless  
1
Downlink port  
Ground connections  
Uplink port  
2, 4, 5, 7, 8, 9  
3
6
B3 UL  
ANT  
Antenna port  
Ordering Information  
Part No.  
Description  
QPQ1297TR7  
QPQ1297EVB  
2,500 pieces on a 7” reel (standard)  
Evaluation Board  
Datasheet, December 4, 2018 | Subject to change without notice  
1 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Absolute Maximum Ratings  
Life Test  
Parameter  
Rating  
Conditions  
Rating  
Storage Temperature  
Operation Temperature  
−40 to +125°C  
−40 to +95ꢀ°C  
+30 dBm DL (1), +85°C (3)  
+23 dBm UL (2), +85°C (3)  
+30 dBm DL (1), +95°C (3)  
+23 dBm UL (2), +95°C (3)  
> 293,000 hours  
> 293,000 hours  
> 102,000 hours  
> 102,000 hours  
Notes:  
1. Power injected into Pin 1 downlink port  
2. Power injected into Pin 6 antenna port  
3. FD-LTE, 5MHz 16QAM, PAR =8dB  
Electrical Specifications (4) Band 3 Uplink  
Test conditions unless otherwise specified. Temperature Range: −40 to +95 °C  
Parameter(5)  
Passband  
Conditions  
Min  
Typꢀ(6)  
Maxꢀ  
1785  
4.1  
Units  
1710  
MHz  
dB  
Max Insertion Loss  
1710ꢀ–ꢀ1785 MHz  
2.3–  
1.8  
1710ꢀ–ꢀ1715 MHz  
2.6  
Average Insertion Loss  
1715ꢀ–ꢀ1780 MHz (Over any 5 MHz bandwidth)  
1780ꢀ–ꢀ1785 MHz  
1.6  
2.4  
2.1  
3.2  
dB  
dB  
ns  
ns  
Amplitude Ripple (7)  
Group Delay Variation  
Input / Output VSWR  
1710ꢀ–ꢀ1785 MHz  
0.7  
2.2  
1710ꢀ–ꢀ1785 MHz  
26.9  
11.9  
1.7:1  
48.0  
25.0  
2.0:1  
1710ꢀ–ꢀ1785 MHz (Over any 5 MHz bandwidth)  
1710ꢀ–ꢀ1785 MHz  
10ꢀ–ꢀ700 MHz  
700ꢀ–ꢀ1000 MHz  
1000ꢀ–ꢀ1400 MHz  
1400ꢀ–ꢀ1600 MHz  
1600ꢀ–ꢀ1685 MHz (Over any 5 MHz bandwidth)  
1685ꢀ–ꢀ1690 MHz (Over any 5 MHz bandwidth)  
1805ꢀ–ꢀ1850 MHz (Over any 5 MHz bandwidth)  
1850ꢀ–ꢀ1855 MHz (Over 5 MHz bandwidth)  
1855ꢀ–ꢀ1875 MHz (Over any 5 MHz bandwidth)  
1875ꢀ–ꢀ1880 MHz (Over 5 MHz bandwidth)  
1880ꢀ–1920 MHz  
1920ꢀ–1980 MHz  
1980ꢀ– 2110 MHz  
2110ꢀ–ꢀ2170 MHz  
2170ꢀ–ꢀ2690 MHz  
2690ꢀ–ꢀ3400 MHz  
3400ꢀ–ꢀ3800 MHz  
3800ꢀ–ꢀ5150 MHz  
5150ꢀ–ꢀ6000 MHz  
30  
38  
20  
35  
19  
10  
44  
48  
47  
47  
38  
30  
38  
40  
32  
13  
6
38  
39  
40  
40  
28  
24  
56  
53  
50  
50  
48  
45  
46  
50  
39  
19  
9
ꢀ–ꢀ  
Attenuation (8)  
dB  
2
7
4
9
EVM  
1712.5ꢀ–ꢀ1782.5 MHz  
3
%
Source/Load Impedance (9) Single-ended  
50  
Notes:  
4. All specifications are based on the Qorvo schematic for the main reference design.  
5. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
6. Typical values are based on average measurements of 12 devices at room temperature.  
7. This is defined as the worst difference between a peak and adjacent valley within defined frequency points.  
8. Relative to zero dB.  
9. This is the optimum impedance in order to achieve the performance shown.  
Datasheet, December 4, 2018 | Subject to change without notice  
2 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Electrical Specifications (1) Band 3 Uplink  
Test conditions unless otherwise specified. Temperature Range: −40 to +85 °C  
Parameter(2)  
Passband  
Conditions  
Min  
Typꢀ(3)  
Maxꢀ  
1785  
3.8  
Units  
MHz  
dB  
1710  
Max Insertion Loss  
1710ꢀ–ꢀ1785 MHz  
2.3  
1710ꢀ–ꢀ1715 MHz  
1.8  
2.6  
Average Insertion Loss  
1715ꢀ–ꢀ1780 MHz (Over any 5 MHz bandwidth)  
1780ꢀ–ꢀ1785 MHz  
1.6  
2.4  
2.1  
3.0  
dB  
dB  
ns  
ns  
Amplitude Ripple (4)  
Group Delay Variation  
Input / Output VSWR  
1710ꢀ–ꢀ1785 MHz  
0.7  
2.2  
1710ꢀ–ꢀ1785 MHz  
26.9  
10.5  
1.7:1  
45.0  
25.0  
2.0:1  
1710ꢀ–ꢀ1785 MHz (Over any 5 MHz bandwidth)  
1710ꢀ–ꢀ1785 MHz  
10ꢀ–ꢀ700 MHz  
700ꢀ–ꢀ1000 MHz  
1000ꢀ–ꢀ1400 MHz  
1400ꢀ–ꢀ1600 MHz  
1600ꢀ–ꢀ1685 MHz (Over any 5 MHz bandwidth)  
1685ꢀ–ꢀ1690 MHz (Over 5 MHz bandwidth)  
1805ꢀ–ꢀ1850 MHz (Over any 5 MHz bandwidth)  
1850ꢀ–ꢀ1855 MHz (Over 5 MHz bandwidth)  
1855ꢀ–ꢀ1875 MHz (Over any 5 MHz bandwidth)  
1875ꢀ–ꢀ1880 MHz (Over 5 MHz bandwidth)  
1880ꢀ–1920 MHz  
1920ꢀ–1980 MHz  
1980ꢀ– 2110 MHz  
2110ꢀ–ꢀ2170 MHz  
2170ꢀ–ꢀ2690 MHz  
2690ꢀ–ꢀ3400 MHz  
3400ꢀ–ꢀ3800 MHz  
3800ꢀ–ꢀ5150 MHz  
5150ꢀ–ꢀ6000 MHz  
30  
38  
20  
35  
23  
12  
50  
48  
47  
47  
38  
30  
38  
40  
34  
13  
6.5  
3
38  
39  
40  
40  
28  
24  
56  
53  
50  
50  
48  
45  
46  
50  
39  
19  
9
ꢀ–ꢀ  
Attenuation (5)  
dB  
4
9
7
EVM  
1712.5ꢀ–ꢀ1782.5 MHz  
3
%
Source/Load Impedance (6) Single-ended  
50  
Notes:  
1. All specifications are based on the Qorvo schematic for the main reference design.  
2. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
3. Typical values are based on average measurements of 12 devices at room temperature.  
4. This is defined as the worst difference between a peak and adjacent valley within defined frequency points.  
5. Relative to zero dB.  
6. This is the optimum impedance in order to achieve the performance shown.  
Datasheet, December 4, 2018 | Subject to change without notice  
3 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Electrical Specifications (1) Band 3 Downlink  
Test conditions unless otherwise specified. Temperature Range: −40 to +95 °C  
Parameter(2)  
Conditions  
Min  
Typꢀ(3)  
Maxꢀ  
1880  
4.0  
Units  
MHz  
dB  
Passband  
1805  
1805ꢀ–ꢀ1880 MHz (-40ꢀtoꢀ+95ꢀ°C)  
1812.5 –ꢀ1872.5 MHz (-40ꢀtoꢀ+95ꢀ°C)  
1805ꢀ–ꢀ1810 MHz (-40ꢀtoꢀ+95ꢀ°C)  
2.8  
2.2  
Max Insertion Loss  
2.7  
2.3  
2.8  
dB  
Average Insertion Loss 1810ꢀ–ꢀ1875 MHz (-40ꢀtoꢀ+95ꢀ°C) (Over any 5 MHz bandwidth)  
1875ꢀ–ꢀ1880 MHz (-40ꢀtoꢀ+95ꢀ°C)  
Amplitude Ripple (4)  
Group Delay Variation  
Input / Output VSWR  
2.2  
2.7  
2.4  
3.4  
1805ꢀ–ꢀ1880 MHz (-40ꢀtoꢀ+95ꢀ°C)  
0.7  
2.2  
dB  
ns  
ns  
1805ꢀ–ꢀ1880 MHz (-40ꢀtoꢀ+95ꢀ°C)  
23.2  
11.7  
2.4:1  
40.0  
25.0  
2.6:1  
1805ꢀ–ꢀ1880 MHz (-40ꢀtoꢀ+95ꢀ°C) (Over any 5 MHz bandwidth)  
1805ꢀ–ꢀ1880 MHz  
10ꢀ–ꢀ700 MHz  
880ꢀ–ꢀ915 MHz  
700ꢀ–ꢀ1000 MHz  
1000ꢀ–ꢀ1400 MHz  
1400ꢀ–ꢀ1600 MHz  
1600ꢀ–ꢀ1710 MHz  
1710ꢀ–ꢀ1770 MHz (Over any 5 MHz bandwidth)  
1770ꢀ– 1775 MHz (Over 5 MHz bandwidth)  
1775ꢀ– 1785 MHz (Over any 5 MHz bandwidth)  
1920ꢀ– 1925 MHz (Over 5 MHz bandwidth)  
1925ꢀ– 1930 MHz (Over 5 MHz bandwidth)  
1930ꢀ– 1965 MHz (Over any 5 MHz bandwidth)  
1965ꢀ– 1980 MHz (Over any 5 MHz bandwidth)  
1980ꢀ– 2300 MHz  
2300ꢀ–ꢀ2400 MHz  
2400ꢀ–ꢀ2690 MHz  
2690ꢀ–ꢀ3400 MHz  
3400ꢀ–ꢀ3800 MHz  
20  
28  
26  
23  
35  
20  
52  
50  
53  
53  
54  
55  
48  
30  
49  
45  
25  
45  
20  
28  
44  
30  
28  
26  
38  
52  
57  
63  
59  
56  
59  
57  
55  
55  
55  
59  
46  
53  
44  
31  
ꢀ–ꢀ  
Attenuation (5)  
dB  
3800ꢀ–ꢀ5150 MHz  
5150ꢀ–ꢀ6000 MHz  
EVM  
1807.5ꢀ–ꢀ1877.5 MHz (-40ꢀtoꢀ+95ꢀ°C)  
3
%
Source/Load Impedance  
Single-ended  
50  
(6)  
Notes:  
1. All specifications are based on the Qorvo schematic for the main reference design.  
2. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
3. Typical values are based on average measurements of 12 devices at room temperature.  
4. This is defined as the worst difference between a peak and adjacent valley within defined frequency points.  
5. Relative to zero dB.  
6. This is the optimum impedance in order to achieve the performance shown.  
Datasheet, December 4, 2018 | Subject to change without notice  
4 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Electrical Specifications (1) Band 3 Downlink  
Test conditions unless otherwise specified. Temperature Range: −40 to +85 °C  
Parameter(2)  
Conditions  
Min  
Typꢀ(3)  
Maxꢀ  
1880  
4.0  
Units  
MHz  
dB  
Passband  
1805  
1805ꢀ–ꢀ1880 MHz  
2.8  
2.2  
Max Insertion Loss  
1812.5 –ꢀ1872.5 MHz  
2.7  
1805ꢀ–ꢀ1810 MHz  
2.3  
2.8  
dB  
Average Insertion Loss  
1810ꢀ–ꢀ1875 MHz (Over any 5 MHz bandwidth)  
1875ꢀ–ꢀ1880 MHz  
2.2  
2.5  
2.4  
3.1  
Amplitude Ripple (4)  
Group Delay Variation  
Input / Output VSWR  
1805ꢀ–ꢀ1880 MHz  
0.7  
2.2  
dB  
ns  
ns  
1805ꢀ–ꢀ1880 MHz  
23.2  
11.7  
2.4:1  
40.0  
25.0  
2.5:1  
1805ꢀ–ꢀ1880 MHz (Over any 5 MHz bandwidth)  
1805ꢀ–ꢀ1880 MHz  
10ꢀ–ꢀ700 MHz  
880ꢀ–ꢀ915 MHz  
700ꢀ–ꢀ1000 MHz  
1000ꢀ–ꢀ1400 MHz  
1400ꢀ–ꢀ1600 MHz  
1600ꢀ–ꢀ1710 MHz  
1710ꢀ–ꢀ1770 MHz (Over any 5 MHz bandwidth)  
1770ꢀ– 1775 MHz (Over 5 MHz bandwidth)  
1775ꢀ– 1785 MHz (Over any 5 MHz bandwidth)  
1920ꢀ– 1925 MHz (Over 5 MHz bandwidth)  
1925ꢀ– 1930 MHz (Over 5 MHz bandwidth)  
1930ꢀ– 1965 MHz (Over any 5 MHz bandwidth)  
1965ꢀ– 1980 MHz (Over any 5 MHz bandwidth)  
1980ꢀ– 2300 MHz  
2300ꢀ–ꢀ2400 MHz  
2400ꢀ–ꢀ2690 MHz  
2690ꢀ–ꢀ3400 MHz  
3400ꢀ–ꢀ3800 MHz  
20  
28  
26  
23  
35  
20  
53  
50  
53  
53  
54  
55  
52  
30  
49  
45  
25  
45  
20  
28  
44  
30  
28  
26  
38  
52  
57  
63  
59  
56  
59  
57  
55  
55  
59  
59  
46  
53  
44  
31  
ꢀ–ꢀ  
Attenuation (5)  
dB  
3800ꢀ–ꢀ5150 MHz  
5150ꢀ–ꢀ6000 MHz  
EVM  
1807.5ꢀ–ꢀ1877.5 MHz  
3
%
Source/Load Impedance (6)  
Single-ended  
50  
Notes:  
1. All specifications are based on the Qorvo schematic for the main reference design.  
2. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
3. Typical values are based on average measurements of 12 devices at room temperature.  
4. This is defined as the worst difference between a peak and adjacent valley within defined frequency points.  
5. Relative to zero dB.  
6. This is the optimum impedance in order to achieve the performance shown.  
Datasheet, December 4, 2018 | Subject to change without notice  
5 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Electrical Specifications (1) Band 3 Isolation  
Test conditions unless otherwise specified. Temperature Range: −40 to +95 °C  
Parameter(2)  
Conditions  
Min  
54  
53  
45  
47  
Typꢀ(3)  
56  
Maxꢀ  
Units  
dB  
1710ꢀ–ꢀ1780 MHz  
1780ꢀ–ꢀ1785 MHz  
1805ꢀ–ꢀ1875 MHz  
1875ꢀ–ꢀ1880 MHz  
Single-ended  
64  
dB  
Isolation  
51  
dB  
51  
dB  
Source/Load Impedance (4)  
Notes:  
50  
1. All specifications are based on the Qorvo schematic for the main reference design.  
2. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
3. Typical values are based on average measurements of 12 devices at room temperature.  
4. This is the optimum impedance in order to achieve the performance shown.  
Electrical Specifications (5) Band 3 Isolation  
Test conditions unless otherwise specified. Temperature Range: −40 to +85 °C  
Parameter(6)  
Conditions  
Min  
54  
53  
48  
48  
Typꢀ(7)  
56  
Maxꢀ  
Units  
dB  
1710ꢀ–ꢀ1780 MHz  
1780ꢀ–ꢀ1785 MHz  
1805ꢀ–ꢀ1875 MHz  
1875ꢀ–ꢀ1880 MHz  
Single-ended  
64  
dB  
Isolation  
51  
dB  
51  
dB  
Source/Load Impedance (8)  
Notes:  
50  
5. All specifications are based on the Qorvo schematic for the main reference design.  
6. Electrical margin has been built into the design to account for the variations due to temperature drift and manufacturing tolerances.  
7. Typical values are based on average measurements of 12 devices at room temperature.  
8. This is the optimum impedance in order to achieve the performance shown.  
Datasheet, December 4, 2018 | Subject to change without notice  
6 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
QPQ1297EVB Evaluation Board  
Bill of Material ꢀ–ꢀ QPQ1297EVB  
Reference Designation  
Description  
Manufacture  
Part Number  
QPQ1297  
U1  
Duplexer, Band 3 BAW  
Connector, SMA RF  
Qorvo  
P1, P2, P3  
PCB  
Radiall USA Inc.  
Multiple  
9602-1111-018  
283666  
Printed Circuit Board, Evaluation  
Datasheet, December 4, 2018 | Subject to change without notice  
7 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Performance Plots Band 3 Uplink  
Test conditions unless otherwise noted: Temp= +25°C  
Uplink Frequency Response  
Uplink Passband Response  
0
-1  
-2  
-3  
-4  
-5  
-6  
-20  
d
B
d
B
-40  
-60  
-80  
1595  
1695  
1795  
1895  
1995  
1672.5  
1710  
1747.5  
1785  
1822.5  
Frequency (MHz)  
Frequency (MHz)  
Uplink WidebandResponse  
Uplink Return Loss  
0
-10  
-20  
-30  
-40  
-50  
-60  
-70  
0
-10  
-20  
-30  
d
B
d
B
10  
1507.5  
3005  
4502.5  
6000  
1672.5  
1710  
1747.5  
1785  
1822.5  
Frequency (MHz)  
Frequency (MHz)  
Uplink Path - Ant Port Impedance  
Uplink Port Impedance  
1
1
0.8  
0.6  
0.4  
0.2  
0
0.8  
0.6  
0.4  
0.2  
0
0
-1  
-0.5  
0
0.5  
1
-1  
-0.5  
0.5  
1
-0.2  
-0.4  
-0.6  
-0.8  
-1  
-0.2  
-0.4  
-0.6  
-0.8  
-1  
Datasheet, December 4, 2018 | Subject to change without notice  
8 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Performance Plots Band 3 Downlink  
Test conditions unless otherwise noted: Temp= +25°C  
Downlink Frequency Response  
Downlink Passband Response  
0
-1  
-2  
-3  
-4  
-5  
-6  
-10  
-20  
-30  
d
B
d
B
-40  
-50  
-60  
-70  
1595  
1695  
1795  
1895  
1995  
1767.5  
1805  
1842.5  
1880  
1917.5  
Frequency (MHz)  
Frequency (MHz)  
Downlink Wideband Response  
Downlink Return Loss  
0
0
-10  
-20  
-30  
-10  
-20  
-30  
-40  
-50  
-60  
-70  
d
B
d
B
10  
1507.5  
3005  
4502.5  
6000  
1767.5  
1805  
1842.5  
1880  
1917.5  
Frequency (MHz)  
Frequency (MHz)  
Downlink Path - Ant Port Impedance  
Downlink Port Impedance  
1
1
0.8  
0.6  
0.4  
0.2  
0
0.8  
0.6  
0.4  
0.2  
0
-1  
-0.5  
0
0.5  
1
-1  
-0.5  
0
0.5  
1
-0.2  
-0.4  
-0.6  
-0.8  
-1  
-0.2  
-0.4  
-0.6  
-0.8  
-1  
Datasheet, December 4, 2018 | Subject to change without notice  
9 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Performance Plots Isolation  
Test conditions unless otherwise noted: Temp= +25°C  
Isolation  
0
-20  
-40  
d
B
-60  
-80  
-100  
1595  
1695  
1795  
1895  
1995  
Frequency (MHz)  
Antenna Return Loss  
0
-10  
-20  
-30  
d
B
1672.5  
1733.75  
1795  
1856.25  
1917.5  
Frequency (MHz)  
Datasheet, December 4, 2018 | Subject to change without notice  
10 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Package Dimensions  
Notes:  
1. All dimensions are in millimeters. Angles are in degrees.  
2. Dimension and tolerance formats conform to ASME Y14.4M-1994.  
3. The terminal #1 identifier and terminal numbering conform to JESD 95-1 SPP-012.  
Datasheet, December 4, 2018 | Subject to change without notice  
11 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Package Marking  
Package Marking  
Qorvo Logo  
Product Identifier: 1297  
Trace Code: XXXX  
PCB Mounting Pattern  
Notes:  
1. All dimensions are in millimeters. Angles are in degrees.  
2. This drawing specifies the mounting pattern used on the Qorvo evaluation board for this product. Some modification may be  
necessary to suit end user assembly materials and processes.  
Datasheet, December 4, 2018 | Subject to change without notice  
12 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Tape and Reel Information Carrier and Cover Tape Dimensions  
Tape and reel specifications for this part are also available on the Qorvo website.  
Standard T/R size = 2500 pieces on a 7” reel.  
Feature  
Measure  
Symbol  
Size (in)  
0.094  
0.114  
0.043  
0.157  
0.079  
0.138  
0.213  
0.315  
Size (mm)  
2.40  
Length  
A0  
B0  
K0  
P1  
P2  
F
Width  
2.90  
Cavity  
Depth  
1.10  
Pitch  
4.00  
Cavity to Perforation - Length Direction  
2.00  
Centerline Distance  
Cavity to Perforation - Width Direction  
3.50  
Cover Tape  
Carrier Tape  
Width  
Width  
C
5.40  
W
8.00  
Datasheet, December 4, 2018 | Subject to change without notice  
13 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Tape and Reel Information Reel Dimensions  
Tape and reel specifications for this part are also available on the Qorvo website.  
Standard T/R size = 2,500 pieces on a 7” reel.  
Feature  
Measure  
Symbol  
Size (in)  
6.969  
0.559  
0.346  
2.283  
0.512  
0.079  
0.787  
Size (mm)  
177.0  
14.2  
Diameter  
A
W2  
W1  
N
Flange  
Thickness  
Space Between Flange  
Outer Diameter  
Arbor Hole Diameter  
Key Slit Width  
Key Slit Diameter  
8.8  
58.0  
C
13.0  
Hub  
B
2.0  
D
20.0  
Datasheet, December 4, 2018 | Subject to change without notice  
14 of 15  
www.qorvo.com  
QPQ1297  
®
FDD Band 3 BAW Duplexer  
Handling Precautions  
Parameter  
Rating  
Standard  
ESDꢀ–ꢀHuman Body Model (HBM)  
Class 1C  
ESDAꢁ/ꢁJEDEC JS-001-2012  
ESDAꢁ/ꢁJEDEC JS-002-2014  
IPC/JEDEC J-STD-020  
Caution!  
ESD-Sensitive Device  
ESDꢀ–ꢀCharged Device Model (CDM) Class C3  
MSLꢀ–ꢀMoisture Sensitivity Level  
Level 3  
Solderability  
Compatible with both lead-free (260°C max. reflow temp.) and tin/lead (245°C max. reflow temp.) soldering processes.  
Solder profiles available upon request.  
Contact plating: NiAu (Plating thickness: Ni 5.0 ± 3.0 μm; Au 0.10 μm min.)  
RoHS Compliance  
This part is compliant with 2011/65/EU RoHS directive (Restrictions on the Use of Certain Hazardous Substances in Electrical and  
Electronic Equipment) as amended by Directive 2015/863/EU.  
This product also has the following attributes:  
Lead Free  
Halogen Free (Chlorine, Bromine)  
Antimony Free  
TBBP-A (C15H12Br402) Free  
PFOS Free  
SVHC Free  
Pb  
Contact Information  
For the latest specifications, additional product information, worldwide sales and distribution locations:  
Web: www.qorvo.com  
Tel: 1-844-890-8163  
Email: customer.support@qorvo.com  
For technical questions and application information:  
Email: appsupport@qorvo.com  
Important Notice  
The information contained herein is believed to be reliable; however, Qorvo makes no warranties regarding the information contained  
herein and assumes no responsibility or liability whatsoever for the use of the information contained herein. All information contained  
herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for  
Qorvo products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any  
patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by  
such information. THIS INFORMATION DOES NOT CONSTITUTE A WARRANTY WITH RESPECT TO THE PRODUCTS DESCRIBED  
HEREIN, AND QORVO HEREBY DISCLAIMS ANY AND ALL WARRANTIES WITH RESPECT TO SUCH PRODUCTS WHETHER  
EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE,  
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  
Without limiting the generality of the foregoing, Qorvo products are not warranted or authorized for use as critical components in medical,  
life-saving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal  
injury or death.  
Copyright 2018 © Qorvo, Inc. | Qorvo is a registered trademark of Qorvo, Inc.  
Datasheet, December 4, 2018 | Subject to change without notice  
15 of 15  
www.qorvo.com  

相关型号:

QPQ1297EVB

FDD Band 3 BAW Duplexer
QORVO

QPQ1297TR7

FDD Band 3 BAW Duplexer
QORVO

QPQ1298

B41 Sub-Band 160 MHz BAW Filter
QORVO

QPQ1298EVB

B41 Sub-Band 160 MHz BAW Filter
QORVO

QPQ1298TR7

B41 Sub-Band 160 MHz BAW Filter
QORVO

QPQ1902

2437 MHz BAW Filter
TRIQUINT

QPQ1902-EVB

2437 MHz BAW Filter
TRIQUINT

QPQ1903

Wi-Fi UNII1-2a bandBoost Filter
QORVO

QPQ1903EVB

Wi-Fi UNII1-2a bandBoost Filter
QORVO

QPQ1903SB

Wi-Fi UNII1-2a bandBoost Filter
QORVO

QPQ1903SR

Wi-Fi UNII1-2a bandBoost Filter
QORVO

QPQ1903TR13

Wi-Fi UNII1-2a bandBoost Filter
QORVO