RAC03E-K [RECOM]

3 Watt 1.45” x 0.95” Single Output;
RAC03E-K
型号: RAC03E-K
厂家: RECOM INTERNATIONAL POWER    RECOM INTERNATIONAL POWER
描述:

3 Watt 1.45” x 0.95” Single Output

文件: 总6页 (文件大小:1081K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 85 to 305VAC input voltage range  
• 4kVAC isolation input/output  
• Operating temperature: -40°C to +85°C  
• Full load output power up to 75°C  
• Low profile of 15.4mm height  
• Household and ITE certified  
Features  
AC/DC Converter  
Regulated  
Converter  
RAC03E-K/277  
• EMC compliance EN55032 class “B”  
Description  
3 Watt  
1.45” x 0.95”  
Single Output  
The cost-efficient RAC03E-K/277 AC/DC converter series has an input range of nominal 100VAC to an  
enhanced 277VAC, delivering an uncompromising 3 watts of output power with tightly regulated outputs  
from 3.3V to 24VDC. These low profile, encapsulated print-mountable modules in an industry-standard  
pinout deliver full output power from -40°C to +75°C and are certified for operation up to +85°C air  
ambient with output power reduced to 1.8W. This series of AC/DC modules holds international safety  
certifications for industrial, domestic, ITE, and household use. With 4kVAC input to output isolation, they  
are suitable for worldwide applications in automation control, industry 4.0, IoT and household automation.  
Due to their LPS (Limited Power Source) and reinforced class II installation rating for floating outputs and  
their significantly wide margin to class B EMC compliance without external components, these are the  
easiest to use, versatile power modules in the industry.  
3
Selection Guide  
Part  
Number  
Input  
Voltage Range  
[VAC]  
Output  
Voltage  
[VDC]  
Output  
Current  
[mA]  
Efficiency  
typ. (1)  
[%]  
RoHS2  
+
REACH  
ERP  
compliant  
compliant  
compliant  
10 from 10  
RAC03E-3.3SK/277  
RAC03E-05SK/277  
RAC03E-12SK/277  
RAC03E-15SK/277  
RAC03E-24SK/277  
85-305  
85-305  
85-305  
85-305  
85-305  
3.3  
5
900  
600  
250  
200  
125  
68  
73  
75  
77  
79  
I
12  
15  
24  
E227436  
Notes:  
H
Note1: Efficiency is tested at nominal input and full load at +25°C ambient  
CERTIFIED  
EN-60335-1  
s
Model Numbering  
UL/IEC/EN62368-1 certified  
CAN/CSA C22.2 No. 62368-1 certified  
EN60335-1 (pending)  
RAC03E- SK/277  
nom. Output Power  
nom. Output Voltage  
Single  
EN62233 (pending)  
IEC/EN61558-1/2-16 (pending)  
EN55032/EN55035 compliant  
CB Report  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Nominal Input Voltage  
50/60Hz  
100VAC  
277VAC  
47-63Hz  
DC  
85VAC  
120VDC  
277VAC  
305VAC  
430VDC  
70mA  
50mA  
40mA  
10A  
(2,3)  
Input Voltage Range  
Input Current  
115VAC  
230VAC  
277VAC  
115VAC  
230VAC  
277VAC  
cold start at  
25°C  
Inrush Current  
20A  
25A  
No load Power Consumption  
ErP Standby Mode Conformity  
(Maximum output power available for Module Input Power=  
stated maximum input power)  
75mW  
0.5W  
1.0W  
0.32W  
0.68W  
Notes:  
Note2: The products were submitted for safety files at AC-Input operation (90-305VAC)  
(7)  
Note3: Refer to “Derating Graph  
continued on next page  
www.recom-power.com  
REV.: 0/2021  
PA-1  
RAC03E-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
BASIC CHARACTERISTICS  
Parameter  
Input Frequency Range  
Minimum Load  
Condition  
AC Input  
Min.  
47Hz  
0%  
Typ.  
Max.  
63Hz  
115VAC  
230VAC  
277VAC  
0.55  
0.45  
0.40  
Power Factor  
Start-up Time  
Rise Time  
15ms  
10ms  
115VAC  
230VAC  
277VAC  
15ms  
80ms  
120ms  
Hold-up Time  
Internal Operating Frequency  
100% load at nominal Vin  
132kHz  
120mVp-p  
1% of Vout  
3.3, 5Vout  
others  
(4)  
Output Ripple and Noise  
20MHz BW  
Notes:  
Note4: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)  
Efficiency vs. Load  
RAC03E-3.3SK/277  
RAC03E-05SK/277  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
277VAC  
115VAC  
230VAC  
277VAC  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
RAC03E-12SK/277 / RAC03E-24SK/277  
RAC03E-15SK/277  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
115VAC  
230VAC  
277VAC  
115VAC  
230VAC  
277VAC  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
continued on next page  
REV.: 0/2021  
www.recom-power.com  
PA-2  
RAC03E-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
REGULATIONS  
Parameter  
Condition  
Value  
1.0% max.  
0.5% typ.  
0.5% typ.  
Output Accuracy  
Line Regulation  
Load Regulation (5)  
low line to high line, full load  
10% to 100% load  
10% load step change  
recovery time  
6.0% max.  
350µs typ.  
Transient Response  
Notes:  
Note5: Operation below 10% load will not harm the converter, but specifications may not be met  
Deviation vs. Load  
RAC03E-3.3SK/277  
RAC03E-05SK/277  
1.0  
1.0  
0.75  
0.5  
0.75  
0.5  
0.25  
0
0.25  
0
-0.25  
-0.5  
-0.75  
-0.25  
-0.5  
-0.75  
-1.0  
-1.0  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
RAC03E-12SK/277 / RAC03E-24SK/277  
RAC03E-15SK/277  
1.0  
0.75  
0.5  
1.0  
0.75  
0.5  
0.25  
0
0.25  
0
-0.25  
-0.5  
-0.75  
-0.25  
-0.5  
-0.75  
-1.0  
-1.0  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
PROTECTIONS  
Parameter  
Type  
Value  
Input Fuse  
internal  
fusible resistor  
Hiccup mode, auto recovery  
120% - 260%, hiccup mode  
120% - 300%, hiccup mode  
OVCII  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Current Protection (OCP)  
Over Voltage Category (OVC)  
Isolation Voltage (6)  
I/P to O/P  
1 minute  
4kVAC  
Notes:  
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
continued on next page  
www.recom-power.com  
REV.: 0/2021  
PA-3  
RAC03E-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
PROTECTIONS  
Parameter  
Condition  
I/P to O/P, Isolation Voltage 500VDC  
I/P to O/P, 100KHz/0.1V  
@ 277VAC  
Value  
1Gmin.  
Isolation Resistance  
Isolation Capacitance  
Leakage Current  
Insulation Grade  
100pF max.  
0.25mA max.  
reinforced  
ENVIRONMENTAL  
Parameter  
Operating Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
Operating Altitude  
Condition  
Value  
-40°C to +85°C  
+95°C  
(7)  
@ natural convection 0.1m/s refer to “Derating Graph ”  
0.03%/K  
2000m  
Operating Humidity  
non-condensing  
20% - 90% RH max.  
PD2  
Pollution Degree  
10-500Hz, 2G10min./1cycle, period 60min.  
each along x,y,z axes  
Vibration  
+25°C  
+40°C  
2260 x 103 hours  
MTBF  
according to MIL-HDBK-217F, G.B.  
230VAC/60Hz and full load +50°C  
2040 x 103 hours  
Design Lifetime  
>30 x 103 hours  
Derating Graph (7)  
(@ Chamber and natural convection 0.1m/s)  
RAC03E-3.3SK/277  
others  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
115-240VAC nom.  
100VAC nom.  
115-240VAC nom.  
100VAC nom.  
10  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70 80 90  
-40 -30 -20 -10  
0
10 20 30 40 50 60 70 80 90  
85  
65 75 85  
Ambient Temperature [°C]  
Ambient Temperature [°C]  
Notes:  
Note7: Output power derating for Line-input of less than 90VAC (derate linearly from 100% at 90VAC to 85% at 85VAC)  
www.recom-power.com  
REV.: 0/2021  
PA-4  
RAC03E-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
SAFETY AND CERTIFICATION  
Certificate Type (Safety)  
Report Number  
Standard  
E491408-A6014-  
UL  
UL62368-1:2019 3rd Edition  
CAN/CSA-C22.2 No. 62368-1:2019  
Audio/Video, information and communication technology equipment - Part 1: Safety requirements  
Audio/Video, information and communication technology equipment - Safety requirements  
(CB Scheme)  
IEC62368-1:2018 3rd Edition  
200703001-1  
Audio/Video, information and communication technology equipment - Safety requirements (LVD)  
Household and similar electrical appliances – Safety – Part 1: General requirements (LVD)  
EN IEC 62368-1:2020+A11:2020  
EN60335-1:2012 + A11:2014  
(pending)  
(pending)  
Measurement methods for electromagnetic fields of household appliances and similar apparatus  
with regard to human exposure  
EN62233:2008  
IEC61558-1:2005 2nd Edition + A1:2009  
EN61558-1:2005 + A1:2009  
Safety of power transformers, power supplies, reactors and similar products for supply voltages  
up to 1100 V (CB Scheme)  
(pending)  
(pending)  
(pending)  
(pending)  
Safety of power transformers, power supplies, reactors and similar products for supply voltages  
up to 1100 V  
Safety of power transformers, power supplies, reactors and similar products for supply voltages  
up to 1100 V Part 2: Particular requirements (CB Scheme)  
IEC61558-2-16:2009 1st Edition + A1:2013  
Safety of power transformers, power supplies, reactors and similar products for supply voltages  
up to 1100 V Part 2: Particular requirements  
EN61558-2-16:2009 + A1:2013  
RoHS 2011/65/EU + AM2015/863  
RoHS2  
EMC Compliance (Industrial)  
Electromagnetic compatibility of multimedia equipment – Emission Requirements  
Condition  
Standard / Criterion  
EN55032:2015, Class B  
EN55035:2017  
Electromagnetic compatibility of multimedia equipment – Immunity requirements  
Air: 2, 4 ,8kV;  
Contact: 4kV  
IEC61000-4-2:2008 , Criteria B  
EN61000-4-2:2009, Criteria B  
ESD Electrostatic discharge immunity test  
3V/m: 80-1000MHz, 1800MHz,  
2600MHz, 3500MHz, 5000MHz  
Radiated, radio-frequency, electromagnetic field immunity test  
IEC/EN61000-4-3:2006 + A2:2010, Criteria A  
Fast Transient and Burst Immunity  
Surge Immunity  
AC Port: 1kV  
AC Port: 1kV  
IEC/EN61000-4-4:2012, Criteria B  
IEC/EN61000-4-5:2014, Criteria B  
3Vrms: 0.15-10MHz  
3-1Vrms: 10-30MHz  
1Vrms: 30-80MHz  
IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A  
IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A  
IEC61000-4-6:2013/EN6100-4-6:2014, Criteria A  
IEC61000-4-8:2009  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
EN61000-4-8:2010  
Voltage Dips and Interruptions  
IEC/EN61004-11:2004  
IEC/EN61000-3-2:2019  
EN61000-3-3:2013+A1  
Limits of Harmonic Current Emissions  
Limits of Voltage Fluctuations & Flicker  
Clause 5  
Limitations on the amount of electromagnetic interference allowed from digital  
and electronic devices  
FCC 47 CFR Part 15 Subpart B, Class B  
DIMENSION AND PHYSICAL CHARACTERISTICS  
Parameter  
Type  
case/baseplate  
Value  
black plastic (UL94V-0)  
silicone (UL94V-0)  
FR4 (UL94V-0)  
Material  
potting  
PCB  
Dimension (LxWxH)  
Weight  
37.0 x 24.0 x 15.4mm  
22.8g typ.  
continued on next page  
www.recom-power.com  
REV.: 0/2021  
PA-5  
RAC03E-K/277  
AC/DC Converter  
Series  
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)  
Dimension Drawing (mm)  
General tolerances according to ISO 2768-m  
(table for reference only)  
embossed logo  
ꢀimension range  
0ꢁ5 - ꢂ mm  
ꢂ - 30 mm  
30 - 120 mm  
120 - 400 mm  
ꢃoleranꢄes  
0ꢁ1 mm  
0ꢁ2 mm  
0ꢁ3 mm  
0ꢁ5 mm  
37.0  
36.4  
23.4  
Pinning Information  
Pin #  
Single  
VAC in (L)  
VAC in (N)  
NC  
-Vout  
+Vout  
1
2
3
4
5
0.1  
NC= no connection  
Ø0.60  
Recommended Footprint Details  
2.54  
3.26  
10x 2.54= 25.4  
1
2
3
4
5
4
3
Restricted Area:  
Pin be considered  
secondary side referenced  
Bottom View  
1
2
5
5.08  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
Packaging Dimension (LxWxH)  
Packaging Quantity  
tube  
490.0 x 26.6 x 25.3mm  
12pcs  
Storage Temperature Range  
Storage Humidity  
-40°C to +85°C  
95% RH max.  
non-condensing  
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 0/2021  
PA-6  

相关型号:

RAC03E-K/277

3 Watt 1.45” x 0.95” Single Output
RECOM

RAC04

AC/DC-Converter with 3 year Warranty
RECOM

RAC04-0512DA

Ultracompact AC-DC Power Supply
RECOM

RAC04-0512DA/277

AC/DC CONVERTER 5V 12V 4W
ETC

RAC04-0512DC

AC/DC-Converter with 3 year Warranty
RECOM

RAC04-0512DC/

4 Watt Single Dual Output
RECOM

RAC04-0512DC/230

4 Watt Single Dual Output
RECOM

RAC04-0512DC/277

4 Watt Single and Dual Output
RECOM

RAC04-0512DC230

Universal Input 80-264VAC
RECOM

RAC04-0512DC277

50mW max. No Load Power Consumption
RECOM

RAC04-05DC

AC/DC-Converter with 3 year Warranty
RECOM

RAC04-05DC/230

4 Watt Single Dual Output
RECOM